Transmission System Total Cost of Ownership

Similar documents
DTU-52 Series. High-Power Digital TV Transmitter. Features

Maxiva UAX Compact Class

Eaton 93PM UPS Where aesthetics meet intelligence.

DTU-52 Series High-Power Liquid-Cooled Digital UHF TV Transmitter

Cooling Capacity Factor (CCF) Reveals Stranded Capacity and Data Center Cost Savings

328 Innovation Blvd. 1 Wheaton Road, Witham

Data Center Facility Basics

Cooling Small Server Rooms Can Be. - Jim Magallanes Computer Room Uptime: Uptime Racks:

Auxiliary HVAC RAM ProMaster. Standard Tie-in Extreme Climate System

york air-conditioning products Residential & VRF News 2015

Opportunity of Energy Saving in electrical path is lesser as compared to other areas

Our data centres have been awarded with ISO 27001:2005 standard for security management and ISO 9001:2008 standard for business quality management.

Liebert Hiross HPW The High Performance Wallmount Cooling Solutions for Telecom Mobile Remote Access Nodes

New Deluxe Wall Mounted Heat Pump Series EXTERIOS

Applications. Key Features. Benefits. Contact us. Solution for TETRA coverage. AIR Repeater TETRA / TETRAPOL 400 RF/RF

Glossary of Heating, Ventilation and Air Conditioning Terms

Data Center Rack Level Cooling Utilizing Water-Cooled, Passive Rear Door Heat Exchangers (RDHx) as a Cost Effective Alternative to CRAH Air Cooling

Half the cost Half the carbon

Rittal Liquid Cooling Series

QuickSpecs. Overview. HP Power Distribution Rack. HP Power Distribution Rack. DA North America Version 5 August 22, 2008 Page 1

New Technology DVB-T2 Products from GatesAir

APC APPLICATION NOTE #92

Energy Efficiency Opportunities in Federal High Performance Computing Data Centers

GREEN FIELD DATA CENTER DESIGN WATER COOLING FOR MAXIMUM EFFICIENCY. Shlomo Novotny, Vice President and Chief Technology Officer, Vette Corp.

Cisco Nexus 7000 Series.

The New Data Center Cooling Paradigm The Tiered Approach

Data Center Equipment Power Trends

Elements of Energy Efficiency in Data Centre Cooling Architecture

Sustainable Design and Energy-Efficient Building Techniques for Existing Housing

LG Electronics AE Company, Commercial Air Conditioning

Managing Data Centre Heat Issues

HEATING AND COOLING SYSTEMS THAT FIT COMFORTABLY WITHIN YOUR BUDGET.

How To Power And Cool A Data Center

UNINTERRUPTIBLE POWER SUPPLIES >9900AUPS UNINTERRUPTIBLE POWER SUPPLIES

CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE. General purpose single phase thyristors and solid state relays Product data.

Eaton 93PM UPS Efficient. Scalable. Innovative.

Liebert CRV Row-Based Cooling Intelligent Precision Cooling For Data Center Equipment. Precision Cooling For Business-Critical Continuity

CoolTeg Plus Chilled Water (CW) version: AC-TCW

Blade Server & Data Room Cooling Specialists

Data Sheet Fujitsu PRIMERGY CX1000 S1 with 38 cloud server nodes

M SERIES REFRIGERANT COIL MODULE REFRIGERANT COILS for R-22, R-407C, R-410A

INNOVATIVE SOLUTION OF DOMESTIC HEATING SPLIT TYPE SPLIT DHW INTEGRATED TYPE MONOBLOC TYPE

Green Data Centre Design

REGULINE 600VA / 1000VA REGULATOR USER MANUAL

Hybrid heat pumps. saving energy and reducing carbon emissions

Datasheet Fujitsu PRIMERGY CX1000 S1 with 38 CX120 S1 The Cool-Central Architecture

SingleBTS Product Portfolio

Chassis, Power Supply, and Element Management

Liquid Cooling Solutions for DATA CENTERS - R.M.IYENGAR BLUESTAR LIMITED.

Features. High Brightness LED Light source

Power and Cooling for Ultra-High Density Racks and Blade Servers

GEOTHERMAL HEATING AND COOLING INTRODUCTION

Eaton 93PM UPS Efficient. Scalable. Innovative.

The following are general terms that we have found being used by tenants, landlords, IT Staff and consultants when discussing facility space.

Increasing Data Center Efficiency by Using Improved High Density Power Distribution

Cisco Nexus 7000 Series Power Supply Modules

Cisco Redundant Power System 2300

APC APPLICATION NOTE #112

DATA CENTER COOLING INNOVATIVE COOLING TECHNOLOGIES FOR YOUR DATA CENTER

Cooking at the Speed of light!

Increasing Energ y Efficiency In Data Centers

APC Matrix-UPS 5kVA 208V/240V In 120/208/240V Out

Cooling/Heat Pump Convertible Air Handlers

Rules of Thumb Energy Efficiency in Buildings

ANALYSIS 2: Photovoltaic Glass Replacement

The High Performance Floormount Indoor Package Cooling Solution. Precision Cooling for Business-Critical Continuity

This presentation is posted for public use. ACEEE does not endorse any product or service.

5 in 1 DVB-T Transmitter & Dual Cast Agile Digital Transposer TV EQUIPMENT

Delivering exceptional performance and Ecovalue. Ecocent

Greensource iseries HY Model Unitary Air Handler/Fan Coil

THE OPTIMAL SOLUTION FOR SMALL AND MEDIUM DATA CENTER

LED Lamp 15W AR111C. A New Experience in Light

Level 1 Energy Audit Report. For: Gladstone Regional Council

SmartOnline V 6kVA 4.2kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 6U Rack/Tower, DB9 Serial, Hardwire

COOLSIDE box R410A. conditioned server - racks for direct installation into the room INVERTER E C

TOTALLY SOLID STATE NON-DIRECTIONAL RADIO BEACONS khz

AIR HANDLERS AIR HANDLERS AIR HANDLERS. RHLA- High Efficiency. featuring R-22 Refrigerant. RHLL- High Efficiency

CURBING THE COST OF DATA CENTER COOLING. Charles B. Kensky, PE, LEED AP BD+C, CEA Executive Vice President Bala Consulting Engineers

SINGLE PACKAGE VERTICAL AIR CONDITIONERS

F9MXE. Product Specifications

Heating & Cooling Efficiency

Two-Phase Evaporative Precision Cooling Systems

Installation Instructions

Our data centres have been awarded with ISO 27001:2005 standard for security management and ISO 9001:2008 standard for business quality management.

HT 30/35CD transmitters

14.5GHZ 2.2KW CW GENERATOR. GKP 22KP 14.5GHz WR62 3x400V

Storage System. Planning Checklist. EC E1, First Edition

Defining Quality. Building Comfort. Precision. Air Conditioning

Phase Modular Finally the benefits of Modular ups are for all

Setting Up and Testing the MAX Hardware

Pre-installation Manual. CONCEPT Processor 305 DW / 405 DW / 505 DW 505 DW XP

Energy-efficient & scalable data center infrastructure design

AisleLok Modular Containment vs. Legacy Containment: A Comparative CFD Study of IT Inlet Temperatures and Fan Energy Savings

RF Power Amplifier PA10W Owner s Manual SpinCore Technologies, Inc.

Direct Contact Liquid Cooling (DCLC ) PRODUCT GUIDE. Industry leading data center solutions for HPC, Cloud and Enterprise markets.

IT White Paper MANAGING EXTREME HEAT: COOLING STRATEGIES FOR HIGH-DENSITY SYSTEMS

Cooling Capacity Factor (CCF) Reveals Stranded Capacity and Data Center Cost Savings

GenStore Archive Cabinet

Radio TV Forum 2014 Rohde & Schwarz Solutions

Installation, operation and maintenance manual TX 35A

Transcription:

Transmission System Total Cost of Ownership February 2013 Featuring GatesAir s Geoff Mendenhall Technology Advisor Copyright 2015 GatesAir, Inc. All rights reserved.

Transmission System - Total Cost of Ownership presented by: Geoffrey N. Mendenhall, P.E. 1

INTRODUCTION High interest among broadcasters / RF network operators to reduce overall transmission facility cost of ownership Total Cost of Ownership (TCO) includes more than initial cost, energy cost, and maintenance of transmission equipment Acquisition, maintenance, operating, training costs of all required systems in transmission facility including cooling and floor space, must be considered to arrive at lowest TCO 2

TOPICS TO BE COVERED Definition of Total Cost of Ownership (TCO) All elements that determine the real, long term, Total Cost of Ownership Besides the reduction in direct operating costs, the benefits of reduced (TCO) include a reduction of carbon footprint in support of green technology. Comprehensive analysis is required including: Trade off s between air and liquid cooling systems Impact on the overall facility, floor space requirements, size, and the thermal efficiency of the transmitter building New evaluation process / analysis tool to design transmission facility for lowest (TCO) (work in progress) Example of the findings from a real world, transmission site (TCO) analysis 3

WHAT IS TOTAL COST OF OWNERSHIP? Acquisition cost of transmission equipment Installation cost of transmission equipment Operating cost of transmission equipment Maintenance cost of transmission equipment Acquisition cost of facility cooling system (HVAC, etc.) Installation cost of facility cooling system (HVAC, etc.) Operating cost of facility cooling system (HVAC, etc.) Maintenance cost of facility cooling system (HVAC, etc.) Periodic replacement cost for facility cooling system (HVAC, etc.) Acquisition or recurring lease cost of floor space required Training costs 4

OTHER FACTORS AFFECTING TCO Average outside air temperature at facility location Cost of energy at facility location Size, construction, and thermal efficiency of facility 5

TRANSMITTER SELECTION IMPACT ON TCO Physical size and foot print (FT 2 ) Power density of transmitter (Watts / FT 3 ) Type of cooling air or liquid Operating efficiency (AC to RF) of the transmitter AC power requirements (1) phase or (3) phase (polyphase may be more expensive to bring to some sites) AC input voltage and voltage regulation requirements Maintainability hot swappable modules, air or liquid filter replacement, and all other maintenance tasks Commonality of transmitter types spares sharing, common training, and operational requirements N+1 transmitter system architecture can reduce number of backup transmitters required 6

TRANSMITTER SELECTION IMPACT ON TCO Choice between air or liquid cooling of transmission equipment makes a significant difference in TCO Initial purchase cost of liquid cooled transmitter is typically higher than an equivalent air cooled transmitter Elimination of most air conditioning costs make breakeven period short and provide significant long term operational savings Typical air conditioning units require ongoing maintenance and replacement on a 5 to 8 year cycle Liquid cooled transmitters have significantly lower energy consumption than combined energy consumption of air cooled transmitter and required air conditioning 7

TRANSMITTER EFFICIENCY OPTIMIZATION 50v LDMOS power amplifier technology 95% efficient power supplies Advanced Real Time Adaptive Correction (RTAC) Advanced Crest Factor Reduction Variable speed cooling system air or liquid Sharing liquid cooling across multiple transmitters 8

FET TECHNOLOGY COMPARISON Comparison of RF Power Attributes vs. Technology 9 Red = Poor Yellow = Neutral Green = Strength (Scale 1 to 5)

FET TECHNOLOGY COMPARISON Practical Pallet Gain 19dB in digital DVB-T operation and 21dB in FM operation Typical efficiency of over 28% in DVB-T operation and 84% in FM operation 10 * Ref. Freescale Semiconductor White Paper: 50 Volt LDMOS An Ideal RF Power Technology for ISM, Broadcast and Radar Applications

Flexiva (FAX) High Power 5kW 40kW Efficiency 72% AC to RF Efficiency Significantly better than competitive products (8-10%) Rivals tube-type transmitters at 30/40kW 11

Flexiva (FAX) High Power 5kW to 40kW 5k/10K 20K 30K 40K 12 FAX High Power (5kW 40kW)

13 TCO ANALYSIS TOOL Harris has developed prototype tool to analyze and calculate TCO for a broadcast transmission facility Visited Riverview ATC site to test tool Consider all elements in power consumption budget Transmitter make / model Transmitter cooling air vs. liquid Cooling system percent of total cost Transmitter percent of total cost Payback period (OPx vs. CAPx)

TCO ANALYSIS TOOL Transmitter Maxiva ULX ATSC Model ULX-2400ATi Television Total Transmitter Acquisition Cost $153,600.00 Installation $22,400.00 Commisioning $11,200.00 Unit Cost $120,000.00 HVAC Acquisition Cost $500.00 HVAC Installation Cost $2,500.00 Annual HVAC Maintenance (Per Ton) $150.00 $150 per ton is industry standard HVAC Annual per visit Rate for Heat Is SEER Annual Rental Fee Preventative First Year Preventative Ducted? Level Maintenance Training Cost Maintenance Price: Per: No. of Visits 12 No $0.00 ft2 4 $400.00 $2,000.00 Region Country/State USA Texas Price Per kw/h: $0.065 Source - IEA "Electricity Information 2010" Product Desription Liquid-Cooled UHF Multimedia TV Transmitter First Year TCO (includes acquistition costs & training) Annual OPEX Five Year TCO Ten Year TCO Fifteen Year TCO Twenty Year TCO Lifetime Total Cost of Ownership $165,890.32 $7,290.32 $195,051.60 $231,503.21 $267,954.81 $304,406.41 Transmitter Maxiva ULX ATSC Total Heat Output Model ULX-2400ATi Heat Output Indoors TX Power Output Before Filter TX Typical Power Consumption 2,500 W 9,617 W 26.00% Annual Air Cooling Requirement (kw- Hr) Total Cooling Needed (BTU/H) Typical Efficiency Total Cooling Needed (Tons) Annual HVAC Maintenance Costs Annual Cooling Costs (100% AC) Annual Cooling Costs (var. AC) 0 W 0 W 0 kw-hr 0.00 0.00 $0.00 $0.00 $0.00 Annual Cooling Annual HVAC Heat Output Annual Cooling Total Cooling Total Cooling Total Heat Output Requirement Maintenance Indoors Costs Needed (BTU/H) Needed (Tons) Liquid +HVAC Costs 4 7,117 W 550 W 3,210 kw-hr $207.98 1,876.68 0.16 $23.46 Model Specifications Air Cooling Liquid Cooling Annual Total Electrical Usage Annual Carbon Emissions (tons) How Many Cars on the Road Annual Transmitter Consumption Cost Annual Electricity Costs (100% AC) Annual Electricity Costs (var. AC) Consumption 87,452 kw-hr 52.47 9.9 $5,458.88 $5,666.86 $5,458.88 Height (RU) Height Width Depth Volume (m 3 /ft 3 ) Efficient Volume (m 3 /ft 3 ) Power Density (KW per m 3 /ft 3 ) Footprint (m 2 /ft 2 ) Dimensions 450.3 MTBF 125548 cm 2004.0 648.0 1194.0 1550.52 403.08 0.00 77.37 in 1145.1 370.3 682.3 167424.6 43524.58 0.00 1754.45 Annual Service & Rental Costs Maintenance Costs $0.00 $1,600.00 Service 14

TCO COMPARISON TOOL Harris #1 Harris #2 Competitor A Competitor B Transmitter Transmitter RF Output Before Filter RF Output Before Filter Maxiva UAX Digital Maxiva ULX ATSC 2,500 W 2,500 W Model Model Power Consumption Power Consumption UAX-2000 ULX-2400ATi 13,820 W 14,000 W Transmitter Installed Cost $135,000.00 $155,600.00 $130,000.00 $125,000.00 HVAC Acquisition Cost $5,200.00 $500.00 $3,657.71 $3,715.87 HVAC Install Cost $7,500.00 $2,500.00 $7,500.00 $7,500.00 Heat Ducted? No No No No Cooling Method? Air Liquid Air Air Annual Rental cost $0.00 $0.00 $0.00 $0.00 Annual TX Maintenance Cost $1,600.00 $1,600.00 $1,600.00 $1,600.00 Annual HVAC Maintenance per ton $150.00 $150.00 $150.00 $150.00 $150 per ton is industry standard KWH Price: $0.065 SEER Level 12 15

TCO COMPARISON TOOL Harris Harris Competitor A Competitor B RF Output Before Filter 2,500 W 2,500 W 2,500 W 2,500 W TX Power Consumption 12,437 W 9,617 W 13,820 W 14,000 W Annual Transmitter Consumption 108,948 kw-hr 84,242 kw-hr 121,063 kw-hr 122,640 kw-hr Efficiency 20.1% 26.0% 18.1% 17.9% Cooling Method Air Liquid Air Air Ducted Heat Output 0 W 0 W 0 W 0 W Heat Output Indoors 9,937 W 550 W 11,320 W 11,500 W Liquid Cooling 0 kw-hr 1,840 kw-hr 0 kw-hr 0 kw-hr # of PA 0 4 0 0 Air Cooling 24,752 kw-hr 1,370 kw-hr 28,197 kw-hr 28,645 kw-hr Btu/H 33906 1877 38625 39240 Tons 2.83 0.16 3.22 3.27 HVAC Maintenance $423.83 $23.46 $482.82 $490.50 Annual Cooling 24,752 kw-hr 3,210 kw-hr 28,197 kw-hr 28,645 kw-hr Total Annual Power Consumption 133,700 kw-hr 87,452 kw-hr 149,260 kw-hr 151,285 kw-hr Annual Cooling Costs $1,603.91 $207.98 $1,827.14 $1,856.19 Carbon Emissions (Tons) 80.22 52.47 89.56 90.77 Annual Transmitter Consumption Costs $7,059.84 $5,458.88 $7,844.90 $7,947.07 Annual OPEX $10,687.58 $7,290.32 $11,754.85 $11,893.76 First Year TCO $158,387.58 $165,890.32 $152,912.56 $148,109.63 5 Year TCO $201,137.90 $195,051.60 $199,931.97 $195,684.67 10 Year TCO $254,575.80 $231,503.21 $258,706.23 $255,153.46 15 Year TCO $308,013.70 $267,954.81 $317,480.49 $314,622.26 16

TCO COMPARISON TOOL $400,000.00 TCO Comparison $350,000.00 $300,000.00 $250,000.00 $200,000.00 $150,000.00 $100,000.00 $50,000.00 UAX-2000 ULX-2400ATi Competitor A Competitor B Linear (UAX-2000) Linear (ULX-2400ATi) Linear (Competitor A) Linear (Competitor B) $0.00 First Year TCO 5 Year TCO 10 Year TCO 15 Year TCO 17

HVAC AIR COOLED TRANSMITTER Pros Familiar technology Simplicity - No concern about liquid spills Cons Higher initial cost of A/C equipment Higher total energy cost Higher maintenance cost High replacement cost of A/C equipment shorter life cycle 18

19 LIQUID COOLED TRANSMITTER Pros Lower overall energy cost Less floor space higher power density Lower initial cost of heat exchanger no duct work Lower maintenance cost no air filters to clean Less frequent replacement cost longer life cycle Much lower noise level Ratio of heat transported by liquid vs. heat liberated into air Can be integrated into facility cooling loop or geothermal cooling loop Highly evolved and desired in DTV installations Cons Less familiar technology to radio broadcasters Higher initial cost of transmitter quickly offset by power savings Concern about liquid spills unlikely with new technology

LIQUID COOLED UHF PA MODULE Module weight < 20kg AC-DC Converters (8) RF Pallets (4) Coolant blind mate connectors Output RF Connector Output Power Combiner Cold Plate 20

MAXIVA LIQUID COOLED UHF PA MODULE User replaceable sub-assemblies shown AC-DC Converter Module RF Pallet 50V LDMOS Device with Heat Spreader Status LED s Diagnostic Port 21

MAXIVA ULX FRONT VIEW Apex M2X Exciters TCU System Controller Redundant Pre-Drivers Liquid Cooled PA s (up to 8) Liquid Cooled Redundant IPA s Liquid Cooled PA s (up to 8) 22

MAXIVA ULX REAR VIEW AC Distribution RF Output Feeder PA Circuit Breakers I/O Panel (on top) Coolant In/Out Hoses Liquid Cooled Upper 8-way Combiner Liquid Cooled Upper 8-way Power Divider 2-Way Output Combiner Liquid Cooled Final Reject Load Redundant Cabinet Blowers (2) Liquid Cooled Lower 8-way Power Divider Liquid Cooled Lower 8-way Combiner 23

24 COOLING SYSTEM BLOCK DIAGRAM

HIGH EFFICIENCY PUMP MODULE Liquid Out Liquid In Pump/Fan Speed Controllers Circuit Breakers Expansion Tank Pumps 25

LIQUID TO AIR HEAT EXCHANGER Compact size (Two sizes available, Tx dependent) Two Configurations Horizontal or Vertical airflow Redundant variable speed fans (50kW Dissipation unit shown, 12kW system is smaller) Horizontal Airflow Vertical Airflow Overall Dimensions: 1,989 mm Long 895 mm Wide 938 mm High Overall Dimensions: 1,989 mm L 540 mm W 940 mm H 26

TCO - OPTIMIZATION SUMMARY Selection of transmission equipment Consider all acquisition, operating and maintenance costs Consider all elements in power consumption budget Cooling technology used in transmitter has large impact on TCO Volume and floor space of transmission equipment affects TCO Building efficiency 27

ACKNOWLEDGEMENTS: Ed Allen Cox Media Roz Clark Cox Media Stefan Wallner - Harris Corporation Victor Fenix - Harris Corporation Tim Anderson - Harris Corporation Rich Redmond - Harris Corporation Monica Collins - Harris Corporation 28

Questions? Geoffrey N. Mendenhall, P.E. Harris Broadcast email: gmendenh@harris.com Visit our website at: http://www.harrisbroadcast.com/ 29