Room Air Conditioners



Similar documents
NewAir AC-10100E / AC-10100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

NewAir AC-10000E, AC-10000H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

NewAir AC-14100E / AC-14100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

Air Conditioner P O R T A B L E. Instruction Manual. Your Guarantee. For model WA-1220M WA-1220H, WA-1220E. Portable Air Conditioner / Heater

Portable Air Conditioner INSTRUCTION MANUAL

USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR

Meaco 30L and Meaco 40L dehumidifier instruction manual

USER INSTRUCTIONS FOR 10 LITRE PORTABLE DEHUMIDIFIER MODEL NO. DHMD102

Room Air Conditioners

Portable Air Conditioner

Use and Care Manual. Model CPA12KH AIR CONDITIONER

PORTABLE AIR CONDITIONER

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MF08CESWW. Voltage rating: 115V~60Hz Power rating : 800W

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CCS. Voltage rating: 115V~60Hz Power rating : 1400W

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MN12CES / MN10CESWW

ACW200C / ACW200CH. Innovative AutoDrain Technology. Owner s Manual Portable Air Conditioner with Heat

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CHCSCS

Important Safeguards

WINDOW ROOM AIR CONDITIONER

USER S MANUAL HSC-24A

Air Conditioner. Portable BTU/h 2.9kW INSTRUCTION MANUAL CWAC11 CPIN Important! Please read these instructions carefully.

PORTABLE AIR CONDITIONER (LOCAL)

Please read this owner s Manual carefully before operating the unit. - Cooling - Heating - Dehumidifying - Fan

PORTABLE AIR CONDITIONER

Get Me Cool Now Portable Air Conditioner User s Manual

Dehumidifier Users manual. For Models: DH45S DH65S

Portable Evaporative Air Cooler. OWNER S MANUAL Read and save these instructions before use. Model: CL30XC

USER S MANUAL FH052EAV1 FH070EAV1. System Air Conditioner (Cooling and Heating) ENGLISH ESPAÑOL FRANÇAIS ITALIANO PORTUGUÊS DEUTSCH E HNIKA

WHYNTER ECO-FRIENDLY 14,000 BTU PORTABLE AIR CONDITIONER WITH HEATER

SPLIT WALL MOUNTED TYPE AIR CONDITIONERS OWNER'S MANUAL

Portable Evaporative Air Cooler for Indoor Use. OWNER S MANUAL Read and save these instructions before use. Model: CL25AE

SILENT10 PORTABLE AIR CONDITIONER USER MANUAL

WALL MOUNTED SPLIT TYPE AIR CONDITIONER

Room Air Conditioners

Portable Air Conditioner

OWNER'S MANUAL R-410A Duct Free Split System Air Conditioner and Heat Pump

Owner s Manual. SRCOOL12K (120V, 60 Hz) SRXCOOL12K (230V, 50 Hz) Portable Air Conditioning Unit. Introduction 2. Important Safety Instructions 2

Service manual. Website: CAUTION - BEFORE SERVICING THE UNIT, READ THE SAFETY - PRECAUTIONS IN THIS MANUAL.

INFRARED QUARTZ WALL HEATER

Meaco 10L Basic Small Home Dehumidifier

Platinum Range PLAC12000HP PORTABLE AIR CONDITIONER WITH HEAT PUMP USER MANUAL HIGH MID COLL HEAT DRY FAN LOW F C TIMER SLEEP SWING

floater imports DF169 ECO AIR COOLER EVAPORATIVE AIR COOLER WITH IONIZER USER S MANUAL

Air Conditioner Water Heater - A Product of HotSpot Energy LLC

Split Type Room Air Conditioner. KSWM units

Meaco DD8L desiccant dehumidifier Instruction Manual

OWNERS MANUAL. PAC 210 U Portable Windowless Air-Conditioner

ENGLISH INSTRUCTION & INSTALLATION MANUAL DUCTLESS MINI SPLIT AIR CONDITIONING SYSTEMS

IMPORTANT INSTRUCTIONS & OPERATING MANUAL. Houston 50 Inch Electric Wall Mounted Fireplace Black / White

Roof Top Air Conditioner INSTALLATION AND OPERATING INSTRUCTIONS

SWIMMING POOL HEAT PUMP

EVAPORATIVE AIR COOLER INSTRUCTION MANUAL

Portable Evaporative Air Cooler for Outdoor, Indoor & Commercial Use. OWNER S MANUAL Read and save these instructions before use.

WHYNTER ECO-FRIENDLY 14,000 BTU PORTABLE AIR CONDITIONER

Operating Instructions Air Conditioner

SERVICE MANUAL. Domestic Air Conditioner. Model. Feature HW-05LN03

LUCCI AIRFUSION QUEST II CEILING FAN

Instruction manual for Firstline FCS12000CH

Hot Water Urns. all models. Helpline. v3.0

USER MANUAL. Bottom Loading Bottled Water Dispenser SAVE THIS MANUAL FOR FUTURE USE. Model #

VACUUM CLEANER INSTRUCTION MANUAL

Vertical Display and Storage B SKOPE Gen2: Three Door Chiller

Portable Evaporative Air Cooler with Heater for indoor use. OWNER S MANUAL Read and save these instructions before use.

Climax Air Inc. DC Inverter Portable Air Conditioner Model VS12 12,000 BTU Introducing The World s Most Efficient Portable Air Conditioner

Wine Cooler with Thermo-Electric Cooling & Heating Technology

USER S MANUAL. Duct Type Series. Free Joint Multi Air Conditioner (Cooling and Heating) FUEA Series E S F I P D G DB A(1) ENGLISH ESPAÑOL

Operating Instructions Split System Air Conditioner

- 2 - IMPORTANT SAFETY REMINDERS

Taurus Series YORK Window Air Conditioners

SAFEGUARDING THE ENVIRONMENT

PORTABLE AIR CONDITIONER CLIMATISEUR PORTATIF ACONDICIONADOR DE AIRE PORTATIL

BD150 INDUSTRIAL DEHUMIDIFIER USER MANUAL

INSTALLATION & USER INSTRUCTIONS

Instruction Manual. Image of SP-3015 & SP Important Safeguards. Automatic Dispensing Hot Water Pot with Reboil Function

SHOWER WATER HEATER MODEL BS 35 / 45 / 60 BS 35 E / 45 E / 60 E OPERATION AND INSTALLATION INSTRUCTIONS

OWNER S MANUAL DRAINVAC ATOMIK PRINTED APRIL

CONTENTS 1. IMPORTANT NOTICE 2 2. TECHNICAL SPECIFICATION 3 3. OPERATION DETAILS 4 4. ELECTRICAL SCHEMATIC DIAGRAM EXPLOSION VIEW 16 6

ICE AIR. Console Water Source Heat Pump (WSHP) OPERATING & MAINTENANCE MANUAL. Wo r l d C l a s s C o m f o r t.

Rapide Inline Ceiling Extractor Fan, White Fascia Rapide Inline Ceiling Extractor Fan, Chrome Fascia

Dehumidifier D 850E. - Instruction manual version 02

Operating instructions in the back. PD1020L

Before using your air conditioner, please read this manual carefully and keep it for future reference. ROOM AIR CONDITIONER

AN500T, AN1000, AN1000T, AN1500, AN1500T AN2000, AN2000T

Central Air Conditioner

UB1 AIR CONDITIONING UNIT INSTALLATION INSTRUCTIONS

IMPORTANT SAFETY INSTRUCTIONS WARNING READ AND SAVE THESE OPERATING AND SAFETY INSTRUCTIONS BEFORE USING THIS HEATER.

Contents. PREPARING YOUR AIR CONDITIONER Safety Precautions... 3 View of the Indoor unit... 8

To suit Daikin FDY "F" Series and FD "F" Series. (and other models incorporating BRC1B62/52 Remote Controller)

INDOOR UNIT/OUTDOOR UNIT

Single Zone LCD Thermostat Operating Instructions

MICA HEATER INSTRUCTION MANUAL Model No: UHM V 50Hz 2200W

Get Cleaning... User Guide Vax Careline: (UK) (ROI) Multifunction. vax.co.uk Series. What s your Vax model number?

English. Symbols used to mark instructions...3. Congratulations...5 Getting the best results...5. Warnings...6 Operating Procedure...

Carpet Washer. vax.co.uk VRS5W. Vax Careline: (UK) (ROI) Vax model number: Version 1.0

Bench Autoclave. Standard Operating Procedure. For Installation, Use and Maintenance

Reverse Cycle Inverter Split System Air Conditioner

CONTENTS 1. IMPORTANT NOTICE 2 2. TECHNICAL SPECIFICATION 3 3. OPERATION DETAILS 4 4. WIRING DIAGRAM EXPLOSION VIEW 12 6.

Contact Details. Please note that some of the contact details on this PDF document may not be current.

ALL IN ONE. Heat Pump Water Heater

Wall Mounted Mini Split Heat Pump Air Conditioner

Transcription:

Installation and Operation Manual Room Air Conditioners Portable Heat Pump Range Local Air Conditioners ECO15P Register your air conditioner Model information can be found on the CE label. Please register your product online at www.ecoair.org. For your future convenience, record the model information below. MODEL NUMBER SERIAL NUMBER PURCHASE DATE

Congratulations! You have purchased the very latest in room air conditioner technology. Your new EcoAir high efficiency room air conditioner will give you many years of dependable service. Many features have been built into your EcoAir portable air conditioner to assure quiet operation, the best circulation of cool, dry air, functional controls, and the most economical operation. Table of contents BS Plug Wiring... 1 Specification... 2 Before Use... 3 Product Description... 5 Installation... 6 Mounting of the Exhaust Pipe... 7 Installation of Carbon Filter... 8 Operation of Control Panel... 9 Self Diagnosis... 12 Drainage... 13 Maintenance... 15 Fault Checklist... 16 Order Form... 17 Disposal When using this air conditioner in the European countries, the follow information must be followed: DISPOSAL: Do not dispose this product as unsorted waste. It is prohibited to dispose of this appliance in domestic household waste. For disposal: A) Contact your local council for disposal. B) The manufacture will take back the old appliance for disposal when you replace with a new product. C) Old products contain valuable resources, which should be recycled as scrap metal. Wild disposal of waste in forests and landscapes endangers your health when hazardous substances leak into the ground-water and find their way into the food chain.

BS Plug Wiring Wiring Instructions: Should it be necessary to change the plug please note the wires in the mains lead are coloured in accordance with the following code: BLUE - NEUTRAL BROWN LIVE GREEN AND YELLOW - EARTH As the colours of the wires in the mains lead of this appliance may not correspond with the coloured markings identifying the terminals in your plug, proceed as follows: 1. The BLUE wire is the NEUTRAL and must be connected to the terminal which is marked with the letter N or coloured BLACK. 2. The BROWN wire is the LIVE and must be connected to the terminal which is marked with the letter L or coloured RED. 3. The GREEN/YELLOW is the EARTH and must be connected to the terminal which is marked with the letter E or or coloured GREEN or GREEN/YELLOW. 4. Always ensure that the cord grip is positioned and fastened correctly. If a 13A (BS 1363) fused plug is used it must be fitted with a 13A fuse. If in doubt consult a qualified electrician. Wiring for a 13 Amp Plug (BS1363) Please note. The Earth Terminal is marked with the letter E or Earth Symbol. - 1 -

SPECIFICATION Model no. ECO15P Cooling capacity 15000 BTU/hr 4395watts Heating capacity 11600 BTU/hr 3400watts Power/Ampere consumption for cooling 1655 W/ 7.5A Power/Ampere consumption for heating 1280 W/ 5.9A Air volume (max. speed) 550m 3 /h Humidity removal capacity 1.3L/hour Power supply Compressor Sound Pressure (Lp) Sound Power (Lw) Refrigerant 220-240V~ 50Hz rotary 50/52/57 db(a) 58/60/65 db(a) R410A (560g) Fan speed 3 Timer Working temperature Exhaust pipe Net Weight Gross Weight Net Dimension (WxHxD) Gross Dimension (WxHxD) REMARK: 1. Measuring condition for above is as per EN 14511 : Cooling DB=35 C, WB=24 C Heating DB=20 C, WB=12 C DB = temperature of dry bulb = room temperature, WB = temperature of wet bulb = relative humidity. 124 hours Cooling: 18 ~ 32 o C Heating: 7 ~ 25 o C Ø 142x1500mm 33.5 kgs 38.5 kgs 422x825x443 mm 490x875x575 mm - 2 -

BEFORE USE GENERAL SAFETY ONLY USE IN THE UPRIGHT POSITION ON A FLAT LEVEL SURFACE AND AT LEAST 50cm FROM ANY OBJECTS (Fig 1&4). DO NOT PLACE OBJECTS ON THE UNIT OR RESTRICT AIR INLET/OUTLET (FIG. 2). CLOSELY SUPERVISE ANY CHILDREN AND PETS WHEN UNIT IS IN USE. THIS APPLIANCE IS NOT INTENDED FOR USE BY PERSONS (INCLUDING CHILDREN) WITH REDUCED PHYSICAL, SENSORY OR MENTAL CAPABILITIES, OR LACK OF EXPERIENCE AND KNOWLEDGE, UNLESS THEY HAVE BEEN GIVEN SUPERVISION OR INSTRUCTION CONCERNING USE OF THE APPLIANCE BY A PERSON RESPONSIBLE FOR THEIR SAFETY. CHILDREN SHOULD BE SUPERVISED TO ENSURE THAT THEY DO NOT PLAY WITH APPLIANCE. ELECTRICAL SAFETY FIG. 2 FIG. 1 FOR INDOOR USE ONLY. SWITCH OFF AND UNPLUG WHEN NOT IN USE. DO NOT USE IN HUMID OR WET ENVIRONMENTS (FIG 3) DO NOT PULL THE UNIT ALONG BY THE CORD. IF THE ELECTRICAL SUPPLY CORD IS DAMAGED, IT MUST BE REPLACED BY AN ELECTRICIAN OR SIMILARLY QUALIFIED PERSON, TO AVOID HAZARD. FIG.3-3 -

FOR MAXIMUM EFFICENCY Do not exceed the recommended room size. Take into the account the number of people or equipment used in the room as these produces heat and will reduce the cooling effectiveness. Avoid opening doors frequently. Keep curtains or blinds closed during the warmest part of the day. Keep filters clean. Once room has reached the desired conditions, reduce temperature and ventilation setting. FIG.4 Locate air conditioner where airflow is not obstructed to increase air flow. Close any air grills, windows or ducting to avoid cooled air escaping during use. - 4 -

PRODUCT DESCRIPTION Front Back FIG.5 1. Control Panel 2. Air vent 3. Handle 4. Caster 5. Air filter 6. Air inlet 7. Cord storage 8. Outlet of exhaust air FIG.6 9. Water stopper / outlet of condensed water Accessories 10. Exhaust hose. 11. PVC strip - for filling the open window space 12. PVC strip - for filling the open window space 13. PVC strip (with hole) - for filling the open window space and with hole for connection to tie-in 14. Outward adaptor - for insertion over hose and into PVC strip (or into hole in the wall/window). 15. Cover for outward adaptor 16. Remote control 17. Active carbon filter 18. Tube for continuous drainage - 5 - FIG.7

INSTALLATION Installation of the exhaust pipe The unit is a portable air conditioner that may be moved from room to room. 1. Using the PVC strip FIG.8 Offer PVC strips to the window gap and adjust to size if necessary. Connect one end of the exhaust pipe to outlet of exhaust air and the other end with the outward adapter. Feed the exhaust hose to the PVC strip as shown and slide window across so that PVC strip is held securely. Note: Take care to maintain protection against intruders. 2. Using the adaptor 50cm FIG.10 FIG.9 Cut a 151mm diameter hole in the wall or window. Feed exhaust hose through the window or wall and attach the threaded adaptor from the outside as shown. When not in use, plug the hole with the cover provided. - 6 -

MOUNTING OF THE EXHAUST PIPE Use only the hose provided and clip exhaust hose and unit adaptor to the back of the air conditioner. FIG.11 Avoid kinks and bends in the exhaust hose as this will cause expelled moist air to build up causing the unit to overheat and shut down. Fig 11 & 12 show correct position. FIG.12 The hose may be extended from 300mm to 1500mm but for maximum efficiency use the shortest length possible. FIG.13 FIG.14-7 -

INSTALLATION OF CARBON FILTER 1. Remove the filter frame from the unit. FIG.15 2. Separate the filter fixer from the filter frame. 3. Remove the active carbon filter from its plastic bag. 4. Insert the active carbon filter into the filter frame. 5. Fix the filter by reassembling the fixer onto the filter frame. 6. Re-fit the filter frame inside the unit. - 8 -

OPERATION OF THE CONTROL PANEL Control panel FIG.16 1. Fan Speed button 2. Timer button 3. Display window 4. Receiver for remote control 5. Heating operation indicator(optional) 6. Mode (function) button 7. Auto operation indicator 8. Cooling operation indicator 9. Fan operation indicator 10. Temperature up button 11. Temperature down button 12. Power indicator 13. Water Full indicator 14. ON/OFF (power) button 15. Sleep function button 16. TiO2(UV light)/ionizer button (optional) 17. Indicator for compressor 18. TiO2(UV light)/ionizer indicator (optional) 19. Sleep operation indicator 20. Timer operation indicator 21. Low ventilation indicator 22. Medium ventilation indicator 23. High ventilation indicator Turning ON/OFF Adjust the louvers to desired angle and position. Press ON/OFF button, the unit will start to work. If the ambient temperature is higher than 23 o C, the unit will work in cool mode. higher than 20 o C but below or equal to 23 o C, the unit will work in ventilation model. below 20 o C, the unit will work in heat function (This is for cooling & heating models only) - 9 -

Indicators of the functions in progress come on at the same time. NOTE! The display window shows the ambient room temperature from 0 o C to 50 o C. To turn the unit off, press ON/OFF button again, then close the air louvers. Setting mode/function Press MODE button to select required working mode: automatic, cooling, fan or heat (Heat is only available for heating & cooling models.) Indicator of the selected mode comes on. Setting Temperature 1. Press 'Temperature up' or 'Temperature down' button to regulate the temperature you desire. 2. The display window will show the temperature you set as you press 'Temperature up' or 'Temperature down' button. Otherwise, it will always show the ambient temperature. 3. The pre-setting temperature of this machine is: 24 o C for cooling, 20 o C for heating. Setting ventilation speed 1. Press SPEED button to choose the fan speed you need, high, medium or low. The sign of high, low or medium fan will light on at the same time. 2. If the unit is in AUTO mode, it will choose the fan speed automatically according to the ambient temperature. Setting timer 1. Press TIMER button to set the operating hours you desire (1 to 24 hours, the sign of timer will light on). The window will show the hour(s) you set as you press TIMER button. If the timer button is not pressed, the unit will work continuously. 2. By pressing the timer but without turning on the other functions, you can PRE-SET the time for the machine to work. For example, if you press the timer to '2', the unit will work automatically after 2 hours. Sleep function 1. In cooling mode, by pressing the SLEEP button, the set temperature will increase 1 o C at the 1st hour, another 1 o C at the second hour, then keeps at that temperature. 2. In heat mode, by pressing the SLEEP button, the set temperature will descend 1 o C at the 1st hour, another 1 o C at the second hour, then keeps at that temperature. - 10 -

3. In SLEEP mode, the fan will be kept at low speed. Re-press the SLEEP button, the setting temperature and ventilation speed will return to the pre-selected one. 4. In SLEEP mode, the unit will shut down automatically after running for 12 hours. 5. Please note, the sleep function is not available while the machine is working in fan mode. Only available in Cooling or Heating mode. Heating function (This is optional, only for cool & heat model.) 1. When using Heat Pump, the ambient warm air is recycled and use to heat the area where it is required. The Exhaust Pipe must be fitted firmly to allow the cold air to be removed outside. 2. Continuous drainage is compulsory while the unit is in heat mode. Working ambient temperature range for heating function is 7 to 25 o C. Regulating air flow direction Adjust the air louvres by hand to control the air flow direction. FIG. 17-11 -

IMPORTANT DIAGNOSIS NOTE This machine is equipped with diagnosis function. Please contact us if your machine displays E1 or E2 codes. The above warnings will also appear on your remote control. Note that this control will require 2 AAA size batteries to operate. NOTE: 1. To prolong the compressor's life, after switching off the unit, please wait for a minimum of 3 minutes before switching on again. FIG.18 2. The cooling system will switch off if the ambient temperature is lower than the set temperature. The fan, however, keeps working on the set level. If the ambient temperature rises above the selected level, the cooling will return to work. 3. The heating will switch off if the ambient temperature is higher than the set temperature. The fan keeps working on the set level. As the ambient temperature drops below the selected level, the heating will return to work. 4. This machine is equipped with ANTI-FROST function. While using the heating function during low temperature, sometimes the heating will stop for a while in order to melt the frost. As this occurs, just wait for the heating to return to work. - 12 -

DRAINAGE During the process of cooling, some water will be extracted from the air into the unit. Most of the water will be evaporated by the coil for maximum efficiency. However in very warm temperature or humid condition, excessive condensation may occur and will require water drainage when tank is full. If the tank is full, both of the compressor and motor will stop. The water full sign will light ON, also the machine will beep as reminder. To make the cooling work again, please empty the water by one of the following ways: 1. Turn off the air conditioner and avoid moving it when full. 2. Position a container (a water tray for example) underneath the drain hole. 3. Remove the drain knob & rubber plug from the drain hole and allow the water to drain out. 4. When the container is almost full, replace the rubber plug in the drain hole and empty the water tray. 5. Repeat until the unit is emptied. 6. Replace the rubber plug and tighten the drain knob firmly. 7. Switch on the unit - the full water or compressor operating indicator should not be flashing. FIG.19 If you wish to operate the unit without the need to empty the water tank, please: Remove the drain knob and rubber plug and retain for future use. Connect the drain tube supplied to the water outlet as shown and locate the other end into a drain. FIG.20-13 -

The drain tube may be extended by adding an extension tube and using a suitable connector. FIG.21 Please note 1. The drain must be at or below the outlet level. 2. Flashing comp / full water indicator will not function in this mode of drainage. 3. If you want to extend the water tube, you can connect it with another tube (OD: 18mm) FIG.22 Special caution for heating function! While using the heating function, please note: 1. Install the exhaust pipe well, in order to exhaust the cool air to outdoor. (Please refer to the instruction manual for installation method.) 2. Fix the drainage to be continuous one (i.e. drain the water by water tube). This is compulsory for use in heating mode. 3. Working range for heating function is 7 to 25 o C (for cooling function, it is 18 to 32 o C). For temperature outside this range, the unit may not work properly. FIG.23-14 -

MAINTENANCE Always unplug the air conditioner from the mains before cleaning. To maximize the efficiency of the air conditioner, clean regularly. Cleaning the housing Use a soft, damp cloth to wipe the body clean. Never use aggressive chemicals, gasoline, detergents, chemically treated cloths, or other cleansing solutions. These all could possibly damage the cabinet. Cleaning the filter Use a vacuum cleaner or tap the filter lightly to remove loose dust and dirt from the filters and then rinse thoroughly under running water (no hotter than 40 o C). Dry thoroughly before replacing. Note: Never operate the unit without the filters. End of season storage Drain any water in the unit then switch the unit to fan mode for a few hours to thoroughly dry the inside. Clean or change the filter Unplug and store the power cord as shown Cover the cord storage Place in the original carton or cover for storage. FIG.24-15 -

FAULT CHECK LIST The air conditioner does not run Is the air conditioner plugged in? Is there a power failure? Is the comp / full water indicator flashing? Is the room temperature below the set temperature? The machine seems to do little cooling Is there direct sunshine? (Please put down the curtain.) Are too many windows or doors open? Are there too many people in the room? Is there something in the room producing lots of heat? The machine seems to do nothing. Is the filter dusty, contaminated? Is the air intake or output blocked up? Is the room temperature below your selected temperature? Too noisy The compressor doesn t run. Is the machine positioned unevenly so as to create vibration? Is the floor underneath the machine uneven? Is so, it is possible the overheat protection of the compressor is on. Just wait for the temperature to drop. Never try to repair or dismantle the unit yourself - 16 -

ORDER FORM Post Order Form Your Details Company Name: Name: Address: Post code: Telephone: Mobile: Fax / Email: Model Number Description of Item Quantity Unit Price Amount Filters 15P-108 & 109 Real Filter & Fixer 14.99 15P-110 Side Filter 14.99 15P-116 Filter Track 8.99 15P-806 Active Carbon Filter 12.99 15P-205 Remote Control 29.99 Exhaust Accessories 15P-141 Exhaust Hose (1.5m) 24.99 15P-137 Tube for continuous drainage 6.99 15P-817 Extension drainage tube (1m) 5.99 15P-135 Water Bung 6.99 Other Accessories 15P-308 Caster Wheels 5.99 15P-144 & 15P-145 & 15P-146 PVC window Kit 29.99 15P-142 & 15P-143 Round Window Connector Set 14.99 Sub Total Standard Delivery (Free) Next Day Delivery (Call) Payment Details (Please tick one below) Credit or Debit Card or Cheque Visa Master Card Solo Visa Electron Card Number: Name on card: Issue Date: / Expiry Date: / Issue No (where applicable): / Card Security No: (Last 3 digits on the signature strip on the reverse of your card) Customer Signature: Total... Name: Date: * Price includes VAT and shipping to UK mainland only (except Scottish Highlands and remote areas) *Note: Please see page 5 for your reference. Fax Form To Us Fax: 0845 388 9313 Mail Form To Us EcoAir Unit 7 Propeller Park, 400 North Circular Road, London NW10 0AB Order Today By Fax, Post Or Via Online Tel: 0845 388 0005 More Information: http://www.ecoair.org

ONE (1) YEAR LIMITED WARRANTY SAVE THIS WARRANTY INFORMATION EcoAir guarantees this product free from defects in materials and workmanship for a period of one (1) year from the date of purchase, limited to parts only. Faults arising from a faulty installation is specifically excluded. This unit must be operated under conditions as recommended, at voltages indicated on the unit. Any attempts made to service or modify the unit by unqualified technician, will render this WARRANTY VOID. The actual product may differ slightly from the illustration. This warranty is in addition to, and does not affect, your statutory rights. For after sales needs, please visit www.ecoair.org/service or email technical@ecoair.org or contact 0845 388 0007 We recommend that you note the details of your purchase below and retain your original proof of purchase receipt with this manual. Keep these documents safe in the event of a warranty claim.please register your product online at www.ecoair.org. Date of purchase: Purchased from (Dealer Name): Retailer name: Model number: Serial number: Date of installation: Copyright Reserved C170