Installation and Operation Guide PD4600 Series Converter Replacement

Similar documents
Installation and Operation Guide for PD4000 Series Power Control Center

Installation and Operation Guide for PD4100 Series Power Control Centers

Installation and Operation Guide for PD5100 Automatic Transfer Switch

Installation/Operator Manual For use with WFCO ULTRA III Power Center Model WF-8712P and WF-8725P

Advantium 2 Plus Alarm

HM-W536 Install Guide

UNIVERSAL LUMBAR INSTALLATION INSTRUCTIONS

ELIXIR POWER CONVERTER / CHARGER

Mobile Data Power Model: MDP-25

P150SC15. Designed for 2015 Ford F150 Super-Cab and Super-Crew vehicles without Sony System Stillwater Designs P150SC15-A

Smart-UPS RT External Battery Pack Stack/Rack-Mount 6U

Mazda CX

AGS. Owner's Manual. Xantrex Automatic Generator Start Control System

AUTO CHARGE 3 STEP AUTOMATIC BATTERY CHARGER

NSI DDR DIMMING RACK POWER DISTRIBUTION UNIT

OWNER'S MANUAL. Model CUL AC Power Inverter/Charger System OM/A96283 REV. A

USE &CARE GUIDE. Remote Faucet Pump System. See Important Safeguards on page 2

CONTENTS TOOLS REQUIRED: Ratchet 13mm Socket 10mm Socket Phillips Screwdriver Pliers Panel Removal Tool. Amp Installation

Master Time Clock MTC-200 MTC-400 MTC-600. Users Manual

Model SRMD Setra Remote Monitoring Display

INSTALLATION GUIDE. Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930

BroadBand PowerShield. User Manual

Installation and Operating Instructions (for chargers shown below)

12-Volt 10-Amp Regulated Power Supply

APOLLO Gate Operators, Inc.

HP ProLiant DL380 G6 Carrier-Grade Server Read Before Install

RI-215A Operator s Manual. Part Number: RK Revision 0 Released: 10/3/05

INSTALLATION & SERVICE MANUAL. Display Panel

Troubleshooting Guide, Freedom and Fleet Power Inverter/Chargers

DCX300 - DCX400 - DCX600

Single Station Remote Alarm

The power module is Feature Number 8800-F2-901.

Models CT-001, CT-002 Owner s Manual

Roof Top Air Conditioner INSTALLATION AND OPERATING INSTRUCTIONS

USER MANUAL WARNING! CONTENTS MODEL 1 SPECIFICATIONS READ ALL INSTRUCTIONS BEFORE PROCEEDING. Non-Programmable Single Stage Heat/Cool Thermostat

Solar Home System. User Manual. AEH-SHS01-10W2L Solar Home System 2 Lamps

StorTrends 3400 Hardware Guide for Onsite Support

FTW 175 VERIZON Wireless Monitoring System Reference Manual Part Number VERIZON

AIM TECHNICAL MANUAL PATENT PENDING STOP REMEMBER TO ACTIVATE UNIT BEFORE TESTING. See page 9 for Activation Instructions

Air-cooled Generator Battery Charger Installation Guidelines

PagePac PAGEPAL V

Contractors Guide Central Inverter System Installation

INSTRUCTION BOOK FOR. Large Cosmopolitan Electrol

Installation Guide Smart-UPS X External Battery Pack SMX120BP

DTM04 TANK MONITOR DTM08 TANK MONITOR Dtm12 TANK MONITOR. Installation and Operation Manual

DUSTTRAK AEROSOL MONITOR SOLAR POWER KIT MODEL

CMD-8000 rev. A COMMANDER SERIES REMOTE CONTROL ENTRY SYSTEM

VK-250 WARRANTY REGISTRATION FORM

Networkfleet 3500 Product Line Installation Guide

INSTALLATION INSTRUCTIONS

PSC POWER STAR LiFE TM

Leak Detection System

PS4-24 OWNERS MANUAL 24 VAC 90 WATT WALL MOUNTED CCTV POWER SUPPLY

Operating Guide Manuel de l utilisateur

ADA COMPLIANT BOX STYLE TELEPHONE INSTALLATION, PROGRAMMING AND OPERATING INSTRUCTIONS FOR MODEL PBX

FW-X240 AUTO TRANSFORMER Installation Manual

ATS Overhead Table Shelf System INSTRUCTION MANUAL

GSD 22 Sounder Module. installation instructions

CT-001, CT-001-Solar Owner s Manual

Table of Contents WARNING SYMBOLS AND DEFINITIONS

16/32 Channel 1U Rack Mount CCTV Power Supply

Mini-led spotlight with magnetic base

ALL WEATHER W-SERIES QUARTZ TUBE ELECTRIC INFRARED RADIANT HEATER INSTALLATION USE & CARE MANUAL

Foodservice Equipment Specialists P.O. Box 880 Saco, ME. / U.S.A * FAX (207)

ROTOR LOADER OWNER S MANUAL

INSTRUCTIONS FOR THE INSTALLATION AND OPERATION OF ACTIVATOR II

6 & 12 Volt Battery and Systems Tester with 100 Amp Load

Automatic Phone-Out Home Monitoring Systems

HP UPS R1500 Generation 3

Portable Solar Kits Owner s Manual

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules.

25 Code GTO Digital Keypad

OPL BASIC. Dosing System for Professional Laundry machines. Contents

Installation and Operating Instructions (for chargers shown below)

Anthro Tablet Charging Cabinets

SOLAR ELECTRIC MODULE ES-124 & ES-62T Owners Manual and Installation Guide

TOYOTA Tundra BACK-UP CAMERA SYSTEM Preparation

AEROMOTIVE Part # INSTALLATION INSTRUCTIONS

Technical Manual. For use with Caller ID signaling types: Belcore 202, British Telecom, & ETSI

BACnet Automation Interface Module (Network Version)

AUTOMATIC BEST BATTERY SELECTOR INSTALLATION & OPERATION BBS-1600 BBS-1600E

AIR CONDITIONER & HEAT PUMP DIGITAL CONTROL FOR DUCTED SYSTEM INSTALLATION AND OPERATING INSTRUCTIONS

Automatic taper of charge rate for superior battery life through good equalization of cells and low water use rate.

Mazda CX up B

Comfort Control Relay Panel (CCRP)

Remote Alarm Monitoring System

Digital echo-charge. Owner s Manual. Xantrex Digital echo-charge Battery Charger

MAC FAUCETS. Owner s Manual. Models: FA444

Powerware Relay-Serial Card User s Guide

Vehicle Restraint Installation Manual

SSW-iLM Keypad. Wire Harness Configuration. Note: This product is designed to be installed and serviced by security and lock industry professionals

Alarm Clock USER GUIDE

, User s Manual

INSTALLATION INSTRUCTIONS

LESTRONIC DV AUTOMATIC 12 OR 24 VOLT DUAL OUTPUT DUAL MODE BATTERY CHARGER MODEL TYPE 12/24EL40-10ET

Before installing unit, please carefully look over Installation Guide.

Dear Customer, User Memo: Please visit us on facebook or twitter! Thank you for purchasing this product.

Operator Manual For use with WFCO ULTRA III Distribution Center WF-8900 Series (model number located on the door assembly label)

POWER TO GET THE JOB DONE

Transcription:

Installation and Operation Guide PD4600 Series Converter Replacement Extended warranties are available for purchase at www.progressivedyn.com Member Thank you for selecting Progressive Dynamics as your choice for your RV power needs! We d like to welcome you to a full line of industry - leading and time - tested products, including our newest addition to the PDI family, the PD4600 Series Converter Replacement Unit. The PD4600 Series Converter Replacement offers break-through technologies that help maintain and lengthen the life of your batteries such as our patented Charge Wizard. The built-in Charge Wizard microprocessor constantly monitors the battery voltage and automatically adjusts the converter output voltage to provide fast recharges and long-term maintenance. The intelligent way to charge and maintain your RV battery! Progressive Dynamics, Inc. 507 Industrial Rd. Marshall, MI 49068 www.progressivedyn.com Patent Numbers: 5,687,066-5,600,550-5,982,643-6,184,649-7,782,002. 2013 Progressive Dynamics, Inc. All rights reserved. 110197 Rev E

Table of Contents Installation Instructions 1-4 The Charge Wizard 5 Reverse Battery Protection 5 Technical Specs 5 LIMITED WARRANTY I. LIMITED WARRANTY: Progressive Dynamics, Inc. warrants its power control center to be free from defects in material or workmanship under normal use and service; and limits the remedies to repair or replacement. II. DURATION: This warranty shall extend for a period of two years from the original date of purchase and is valid only within the continental limits of the United States and Canada. III. WARRANTY EXCLUSIONS: This warranty specifically does not apply to: A. Any product which has been repaired or altered in any way by an unauthorized person or service station; B. Damage caused by excessive input voltage, misuse, negligence or accident; or an external force; C. Any product which has been connected, installed or adjusted or used other than in accordance with the instructions furnished, or has had the serial number altered, defaced or removed; D. Cost of all services performed in removing and re-installing the power converter; and E. ANY LOST PROFITS, LOST SAVINGS, LOSS OF USE OF ENJOYMENT OR OTHER INCIDENTAL DAMAGES ARISING OUT OF THE USE OF, OR INABILITY TO USE, THE PRODUCT. THIS IN- CLUDES DAMAGES TO PROPERTY AND, TO THE EXTENT PERMITTED BY LAW, DAMAGES FOR PERSONAL INJURY. THIS WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES, INCLUDING IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. IV. PROOF OF PURCHASE: A warranty claim must be accompanied by proof of the date of purchase. V. CLAIM PROCEDURE: Upon discovery of any defect, Progressive Dynamics, Inc. shall be supplied the following information at the address listed below: A. Name and address of the claimant; B. Name and model of the product; C. Name, year and model of the recreational vehicle in which the product was installed; D. Date of purchase; and E. Complete description of the claimed defect. Upon determination that a warranty claim exists (a defect in material or workmanship occurring under normal use and service), the converter section shall be shipped postage prepaid to Progressive Dynamics, Inc. together with proof of purchase. The product will be repaired or replaced and returned postage prepaid. For Warranty Service Call: (269) 781-4241 ext 159 P r o g res sive Dy namics, I n c.

Page 1 INSTALLATION INSTRUCTIONS PD4600 SERIES CONVERTER REPLACEMENT KIT General This retrofit kit is intended to replace existing 35, 45, and 55 Amp AC to DC power converters (depending on model). Installation should be completed by a licensed electrician or certified RV Technician. Converter models this kit is intended to replace are as follows, and instructions for replacement of each model are contained in this manual. Model PD4635 (35 Amp) for replacement of: Parallax/Magnetek model 6336 WFCO model 8935 Model PD4645 (45 Amp) for replacement of: Parallax/Magnetek model 6345 Parallax model 7345 WFCO model 8945 Model PD4655 (55 Amp) for replacement of: Parallax/Magnetek model 6355 Parallax model 7355 Parallax model 7155 WFCO model 8955 SAFETY FIRST!!! To insure immediate and continued safety of installation and use of your new Progressive Dynamics Power Converter, please adhere to the following guidelines for ALL installations: 1. Do NOT install a converter whose amperage rating is higher than the one originally installed in your application. Doing so may cause wiring to overheat, resulting in damage to components and/or fire. 2. Disconnect all power sources prior to removal of the old converter. Power sources may include, but are not limited to: 120VAC shore power (unplug shore power cord) Onboard generator (disconnect per manufacturer s instructions) 12VDC battery power (disconnect negative terminal(s) from battery(ies) ) IMPORTANT! Do not discard any components or fasteners until installation is complete and all aspects of power center pass testing. Labeling and/or organizing fasteners as they are removed will improve ease of installation, as some fasteners will be re -used from your current configuration!

Replacement instructions for Parallax/Magnetek Models: 6336, 6345, 6355, 7345, 7355 Page 2 Removal: 1. Disconnect all power sources as outlined on page (1) of this manual. 2. Remove front panel by removing (4) screws at bottom of panel. 3. Remove AC power section cover by removing (2) screws. 4. Disconnect the neutral (white) converter feed wire from distribution block, and hot (black) wire from AC branch breaker. If the utility pigtail is used, remove wire nut. 5. Remove the (2) DC power distribution board mounting screws. 6. Pull the DC board outward and remove the converter+ (blue) wire from the front of the board, and the converter - (white) wire from the BACK side of the board. Pull wires thru the hole at the bottom right of the DC power section. 7. Remove wire from the BATT POS lug on the old DC board, and reconnect to the BATT POS+ lug on the new DC board. Remove the wire from the BATT NEG lug on the FRONT of the old DC board, and reconnect to the BATT NEG- lug on the new DC board. Transfer branch circuit wiring and fuses in this same fashion. 8. Remove the (4) screws securing the old converter assembly to power center, and remove converter assembly. Pull wires thru the hole at the bottom left of the AC power section. Installation: 9. Slide new converter into power center. Route black/white/green wire-set into AC power section and black/ white wire-pair into DC section. Secure converter using (4) screws removed in step #8. 10. In the AC power section, connect new converter neutral (white) wire to neutral distribution block and converter ground (green) wire to ground bar. Connect hot (black) wire to the existing AC branch breaker. If the utility pigtail was used on the original installation, two short lengths of 14AWG wire and a wire nut may be used to provide the utility pigtail. DO NOT install (2) wires into the breaker. 11. Replace AC power section cover and secure using (2) screws removed in step #3. 12. In the DC power section, route new converter DC wires behind new DC power distribution board. Connect new converter power (black) wire to the new DC power distribution board terminal labeled CONV POS+. Connect the negative (white) wire to the DC board terminal labeled CONV NEG-. 13. Making sure new DC feed wires remain behind DC board, secure DC board to power center using (2) screws removed in step #5. 14. Connect 4-pin header on DC board to 4-pin header on converter assembly using 4-wire harness (included). 15. Replace power center cover using (4) screws provided with kit. 16. Transfer DC Distribution branch circuit information to the new label provided with the retrofit kit, and adhere label over existing label on the inside of the power center cover. Affix green Replacement Notice label in any unused area of the power center cover. Steps #3 & 11 Steps #4 & 10 Steps #5 & 13 Steps #8 & 9

Replacement instructions for Parallax/Magnetek Models: 7155 Page 3 Removal: 1. Disconnect all power sources as outlined on page (1) of this manual. 2. Remove front panel by removing (6) screws at bottom of panel. 3. Remove AC power section cover by removing (2) screws. 4. Disconnect the neutral (white) converter feed wire from distribution block and hot (black) wire from AC branch breaker. If the utility pigtail is used, remove wire nut. Pull wires thru the hole at the bottom left of the AC power section. 5. Remove the (2) DC power distribution board mounting screws. 6. Pull the DC board outward and remove the converter+ (blue) and converter- (white) wires from the board. Pull wires thru the hole at the bottom right of the DC power section. 7. Remove POS+ wire from the old DC board, and reconnect to the terminal labeled BATT POS+ on the new DC board. Remove the NEG- wire from the old DC board, and reconnect to the terminal labeled BATT NEG- on the new DC board. Transfer branch circuit wiring and fuses in this same fashion. 8. Remove the (2) screws securing the old converter assembly to power center, and remove converter assembly. Installation: 9. Remove new converter core assembly from provided enclosure, by removing (4) screws securing converter to enclosure and slide converter out. Discard the metal enclosure and screws as they are not used when replacing this model converter. 10. Slide new converter core into power center. Route black/white/green wire-set into AC power section and black/white wire-pair into DC section. Secure converter by placing roll-pin thru converter base tab into mounting rail. 11. In the AC power section, connect new converter neutral (white) wire to neutral distribution block and converter ground (green) wire to ground bar. Connect hot (black) wire to the existing AC branch breaker. If the utility pigtail was used on the original installation, two short lengths of 14AWG wire and a wire nut may be used to provide the utility pigtail. DO NOT install (2) wires into the breaker. 12. Replace AC power section cover and secure using (2) screws removed in step #3. 13. In the DC power section, route new converter DC wires behind new DC power distribution board. Connect new converter power (black) wire to the new DC power distribution board terminal labeled CONV POS+. Connect the negative (white) wire to the DC board terminal labeled CONV NEG-. 14. Making sure new DC feed wires remain behind DC board, secure DC board to power center using (2) screws removed in step #5. 15. Connect 4-pin header on DC board to 4-pin header on converter assembly using 4-wire harness (included). 16. Replace power center cover using (6) screws removed in step #2. 17. Transfer DC Distribution branch circuit information to the new label provided with the retrofit kit, and adhere label over existing label on the inside of the power center cover. Affix green Replacement Notice label in any unused area of the power center cover. Step #10 Steps #5 & 15

Replacement instructions for WFCO Models: 8935, 8945, 8955 Page 4 Removal: 1. Disconnect all power sources as outlined on page (1) of this manual. 2. Remove front panel by opening access door and removing (2) screws. 3. Disconnect the neutral (white) and ground (green) converter feed wires from distribution blocks and hot wire from AC branch breaker. If the utility pigtail is used, remove wire nut. Pull wires thru the hole at the bottom left of the AC power section. 4. Depress tab securing DC Board, and pull the DC board outward. Remove the converter+ (red) and converter- (white) wires from the front of the board. Pull wires thru the hole at the bottom right of the DC power section. 5. Remove POS+ wire from the old DC board, and reconnect to the terminal labeled BATT POS+ on the new DC board. Remove the NEG- wire from the old DC board, and reconnect to the terminal labeled BATT NEG- on the new DC board. Secure new DC board to power center, and transfer branch circuit wiring and fuses in this same fashion. 6. Remove the (2) screws securing the old converter assembly to power center, and remove converter assembly. Installation: 7. Attach new adapter bracket to power center using (2) screws removed in step #6. 8. Remove new converter core assembly from provided enclosure, by removing (4) screws securing converter to enclosure and slide converter out. Discard the metal enclosure and screws as they are not used when replacing this model converter. 9. Slide new converter into power center. Route black/white/green wire-set into AC power section and black/ white wire-pair into DC section. Secure converter by snapping into bracket installed in step #7. 10. In the AC power section, connect new converter neutral (white) wire to neutral distribution block and converter ground (green) wire to ground bar. Connect hot (black) wire to the existing AC branch breaker. If the utility pigtail was used on the original installation, two short lengths of 14AWG wire and a wire nut may be used to provide the utility pigtail. DO NOT install (2) wires into the breaker. 11. In the DC power section, route new converter DC wires to new DC power distribution board. Connect new converter positive (black) wire to the new DC power distribution board terminal labeled +VCC. Connect the negative (white) wire to the DC board terminal labeled NEG-. 12. Connect 4-pin header on DC board to 4-pin header on converter assembly using 4-wire harness (included). 13. Replace power center cover using (2) screws removed in step #2. 14. Transfer DC Distribution branch circuit information to the new label provided with the retrofit kit, and adhere label to the inside of the power center door. Affix green Replacement Notice label over old branch circuit distribution label. Note: (4) screws and (1) roll pin supplied are not used and may be discarded. Steps #3 & 10 Step #4 Step #7

Page 5 Wizard Mode Button The Charge Wizard Operation: While the built-in Charge Wizard automatically determines which operating mode is best suited to recharge or maintain optimum battery condition, the Wizard Mode Button allows for manual override and has an indicator light to indicate the mode of operation. (Located on DC board, included) BOOST MODE Indicated by green LED remaining on. The output voltage is 14.4VDC to rapidly recharge the battery up to 90% of full charge. NORMAL MODE When the battery is between 50% and 90% charged, the green LED will flash once per second. When the battery has reached 90% of full charge, the green LED will flash 2-3 times per second. In this mode the output voltage is 13.6VDC and the converter is safely completing the charge of the battery. STORAGE MODE Indicated by green LED flashing every 6-8 seconds. In this mode the output voltage has been lowered to 13.2VDC, the RV battery is fully charged and the converter is maintaining the charge. WIZARD MODE BUTTON - The manual button has been provided to allow the operator to temporarily override the converter (not recommended) or to verify the converter is operating properly. For manual operation, Press and Hold the button. The indicator light will soon remain ON indicating Boost Mode. Continue to hold the button and the light will blink rapidly indicating the converter is in the Normal Mode. Continue to hold the button until the light blinks slowly indicating the converter is now in the Storage Mode. After the manual button is released the converter will stay in the selected mode. When the battery charge status changes, the converter will return to the automatic mode of operation to prevent damage to the battery. - All times and voltages provided above are approximate. - REVERSE BATTERY PROTECTION CIRCUIT If a battery is accidentally hooked up backwards, the converter will be protected. Easily accessible ATC type fuses will blow when a battery is connected in reverse. All PD4600 Series Converter Replacement units require (2) 30AMP fuses, included, to distribute DC power. Replace with same type and rating. Model PD4635 PD4645 PD4655 Input: 105-130 VAC 50/60 Hz Input: 105-130 VAC 50/60 Hz Input: 105-130 VAC 50/60 Hz Specifications 550 Watts 725 Watts 950 Watts Output: 13.6 VDC, Output: 13.6 VDC, Output: 13.6 VDC, 35 Amps Weight: 9 lbs 45 Amps Weight: 9 lbs 55 Amps Weight: 10 lbs (Specifications subject to change without notice) The DC Section: The DC panel features 12 positions, rated for up to 20A, for accessories including two low-to-full current rated branches. These can be used for lower current devices such as smoke and CO detectors. Each branch has a red LED light that indicates which fuse has blown.

P r o gr e ssive Dynamics, Inc. 507 Industrial Rd Marshall, MI 49068 Visit us on the web for other great products. www.progressivedyn.com