Silicone oil is as the medium and the drying effect is uniform. The Temperature error is less than or equal 1.



Similar documents
LyoBeta. R+D Freeze-Dryers

German engineering under high pressure

Lyophilization Product Line Overview

FVA THIRD-GENERATION VERTICAL SATURATED-STEAM STERILIZERS

OT 40L / 90L. Laboratory Steam Sterilizers

Laboratory Line. Vertical and Bench-Top Life Science Autoclaves

Freezers - Ultrafreezers. Platilab & Irilab Series

Refrigerators - Freezers. Ekofrigolab & Ekobasic Series

Vertical and Benchtop Autoclaves for Life Sciences. Laboratory Line

Probably the best Speed Vacuum Concentrators in the world

BR I Blood Bank Refrigerators

ORGANIC SAMPLE PREPARATION

Visions become real. Temperature control and cooling systems. The innovative and reliable solution

08 FRIDGES & FREEZERS

S G G S G G S G G S G G. FR / MF range. Deep Freezers & Plasma Storage Freezers

STERILIZERS, LABORATORY DRYING OVENS

Thermo Scientific Heratherm Microbiological Incubators. Safe, easy and efficient

DESIGN STANDARDS SECTION

Product-friendly and fast...

TENDER DOCUMENT PURCHASING EQUIPMENT FOR PEPTIDE SYNTHESIS

CPX/HT Series. REFRIGERATED AND HIGH TEMPERATURE DRYER 12 to 2400 CFM. High-performance products. Designed for you!

WATERBATHS AND OILBATHS

york air-conditioning products Residential & VRF News 2015

National Competency Based Skill Training Refrigeration and Air-conditioning Mechanic Logbook

Tabletop Line. Automatic and Semi-Automatic Autoclave Series

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM

18 LITER VOLUME STERILISATION MATERIALS TESTING MEDIA PREPARATION

Guidelines for Storage and Temperature Monitoring of Refrigerated Vaccines

LABOKLAV. Autoclaves Made in Germany.

Model: AC-S13CG x 2. Model No: AC-S13CGx2.doc Version 1.0

Cooling Channel Optimization

Car and commercial cial air conditioning service solutions

Operating ambient temperature range: 5ºC to 50ºC Storage temperature range: -30ºC to 70ºC

Incubators, cooled incubators, drying ovens, sterilizers, climatic chambers

Field Notification Package for V 17A Software for the STP 420D/ES Tissue Processor

Steripro cgmp. Steam Sterilizers

Thermo Scientific VARIOKLAV Modular Laboratory Autoclaves Versatile, space-saving performance for steam sterilization applications

ThermoSorb Desiccant Dryers

List of instruments required for Innovation Projects sanctioned in Deshbandhu College for the year

FLASH TANK ECONOMIZER PRODUCT GUIDE

LABORATORY / MEDICINE / PHARMACEUTICAL REFRIGERATORS

Tools & Equipment Robinair

INNOVATIVE SOLUTION OF DOMESTIC HEATING SPLIT TYPE SPLIT DHW INTEGRATED TYPE MONOBLOC TYPE

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS

EcoCWave. The all-round talent for aqueous part cleaning.

Oil-Free Screw Compressors. Water-injected Technology. Rely on GD to provide the perfect fit

Model Voltage (V/Hz) Power (W) Capacity (L) Chamber size Outside size(mm) Weight (kg) STE-TEN 220/ Ø90x160mm W200xH385xD (Net:28)

GAS HANDLING SYSTEMS VACUUM INSTRUMENT CORPORATION

CoolTeg Plus Chilled Water (CW) version: AC-TCW

Refrigerant Charging Unit ICOGD. 020AH1000 Operating Manual. FR İ-COLD Rev. 00

AIRFREE TECHNIQUE AND SENSITIVE REAGENTS S ECTI O N 1: GLASS W ARE A ND E Q UIP M ENT. A. Using a manifold

CelCulture. CelCulture CO2 Incubator Model CCL-170_-_. CO2 Incubator with Integrated Cooling System Solution for Highly Specialized Applications

Medical Waste Autoclaves. Medical Waste Autoclaves

BB-18 Black Body High Vacuum System Technical Description

Cold Room & Refrigeration System (Casserole Assembly) No of units: 1

Failure code manual. content

Material test chamber with mechanical convection

Solar Hot Water Heaters

Appendix - Controllers 179

Vacuum drying oven for non-flammable solvents

Waterbaths and Oilbaths WNB/WNE/WPE/ONE

AUTOCLAVE STEAM STERILIZERS

Thermo Scientific Sorvall T3 and G3 Centrifuge Series. Capacity, reliability and performance for routine applications

What to Expect From the Examination. How to Study the Plumbing Codes

Refrigeration & HVAC

Laboratory & Scientific Line. Bulk Steam Sterilizers. Since

Laboratory Autoclave SN210/310/510,SQ510/810

Heating oven with mechanical convection

Melting Point. Electrothermal PRODUCT SPECIFICATIONS OPERATION

Kompressoren. Adsorption Dryer AD

Laboratory- and sterilisation equipment HMC EUROPE

Specification. Feature. Option

OUR PRODUCTS TRH-TRS-TRM-TRV. LIQUID RING VACUUM PUMPS AND COMPRESSORS Capacity up to 2100 ACFM Vacuum to 29 Hg. Our Other Products.

Clinic Washer-Disinfectors. Washer-Disinfector Line

Technical data. Danfoss DHP-A

Pressure calibration equipment

Modular Glovebox Systems Gas Purifier Units Antechambers Accessories

USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR

VTS³ and VCS³ Stress Screening Systems. More Power for Maximum Quality Assurance

MILESTONE CLEAN CHEMISTRY LINE DUOPUR TRACECLEAN ULTRA-TRACE INSERTS. A Breakthrough in Reduction and Control of the Analytical Blank MILESTONE

CONTAMINANT REMOVAL FROM CENTRIFUGAL SYSTEMS

Eurovacuum EV Series. Single Stage Oil Sealed Rotary Vane Pump

Medical Air Systems: Scroll

CoolTop. A unique water cooled air-conditioning unit for server room cooling from the top AC-TOPx-CW-240/60

Condensate water pump with neutralisation system

FVA/A1 saturated-steam sterilizer

Dehumidifier D 850E. - Instruction manual version 02

How To Make A Coffee Pot

10 tips for getting more reliability from your air-conditioning system [reliability]

HDA

SECTION MORTUARY REFRIGERATORS

heat treatment equipment & accessories

ALL IN ONE. Heat Pump Water Heater

BSL3 and BSL4 Autoclaves. Laboratory Line

STD - STANDARD VERSION extended possibilities reasonable price wide range of optional equipment

SUB Universal water baths SBB Boiling baths JB, PB Unstirred water baths

Partnership. Medical Waste Autoclaves. Medical Waste Autoclaves

PANASONIC TROUBLE SHOOTING GUIDE

PETRODIST PILODIST. Crude oil distillation systems according to ASTM - standards for fractionation and boiling analysis

Room Air Conditioner SVC MANUAL(Exploded View)

Transcription:

Characteristic: The process of pre-freezing and drying finishes in situ. The freeze dryer is equipped with observation windows and the drying process is intuitive. Silicone oil is as the medium and the drying effect is uniform. The Temperature error is less than or equal 1. The partition-board temperature is adjustable and controlled The drying chamber and cold trap is separated so the water-capture capability is higher and the drying time is shorter. Touching-screen operation, PID controlling, displaying drying curve. The sample tray is square so it s easy to clean and operate. FDL-200F Vertical In-situ freeze dryer with liquid heating No. of trays:6 Trays liquid load capacity:25kg tray temperature: -50 to +70 condenser temperature:-70 Condesor ice capacity:25kg/24h RS232 computer connect Defrost function CIP function optional for top-stopper type MRC.VER.1-4.11

FDL-10F-50/70V vertical in situ freeze dryer 1.pre-freezing at in situ situation, transparent organic glass door to observe working procedure. 2.The tray temperuate adjustable, controllable, detectable ;its suitable for pilot scale and small production. 3.LCD display working situation and PID control, drying curving display on the LCD. 4.optional gas valve to fill with inert gases like nitrogen gas Tech specification: Drying area 0.2 m2 No. of trays 2 Condenser lowest temperature tray temperature range Distance between trays trays size Liquid loading capacity Φ22 vial Φ16 vial Φ14 vial Φ12 vial Vaccum degree Mashine cooling External dimension -50-70 (optional) -50 ~50 70mm 265mm x 400mm x 25mmX2mm 3Kg/24h 2L 370pcs 768pcs 970pcs 1300pcs 10Pa Air cooling 600mm x 660mm x 1100mm 3, Hagavish st. Israel 58817 Tel: 972 3 5595252, Fax: 972 3 5594529 mrc@mrclab.com Page 1 of 1 pages

FREEZE DRYERS F Bench top freeze dry system offer an economical solution for processing light loads of aqueous samples specially designed for use by researchers small footprint simple operation. FDL-10N-50-Series, Bench Top Freeze Dryers FDL-10N-50: 50 C lyophilizer(freeze-dryer) FDL-10N-50-BA FDL-10N-50-8M FDL-10N-50-TD FDL-10N-50-TD-MM Picture Freeze temperature -50 C <15Pa Freeze-dry area 0.12 m 2 0.07 m 2 Tray load 1.2L 0.7L 3kg/24h Sample tray Φ200mm x4 Φ180mm x3 Power supply Machine size (mm) Character 220V 50Hz 800W L380xW500xH340 Big cold tray hole, with sample pre-freeze, stainless 304# cold tray, no pipe in cold tray, anti rust transparent plastic cover for dry chamber, security and direct-viewing stainless sample shelf, the distance between trays is adjustable international standard interface to pump FDL-10N-80-Series, Floor Freeze Dryers FDL-10N-80: 80 C lyophilizer(freeze-dryer) FDL-10N-80-BA FDL-10N-80-8M FDL-10N-80-TD FDL-10N-80-TD-MM Picture Freeze temperature -80 C <15Pa Freeze-dry area 0.12 m 2 0.07 m 2 Tray load 1.2L 0.7L 3kg/24h 4kg/24h 3kg/24h Sample tray Φ200mm x4 lays Φ180mm x3 lays Power supply 220V 50Hz 800W 220V 50Hz 1300W 220V 50Hz 800W Machine size L500xW500xH750 L492xW540xH800 L492xW500xH750 L500xW500xH750 (mm) Big cold tray hole, with sample pre-freeze, stainless 304# cold tray, no pipe in cold tray, anti rust transparent plastic cover for dry chamber, security and direct-viewing Character stainless sample shelf, the distance between trays is adjustable international standard interface to pump 107

F FREEZE DRYERS FDL-10N-50/80T, Bench Top Freeze Dryers FDL-10N-50 T type for multi-manifolds FDL-10N-50T FDL-10N-80T Picture Brief Basic components: 2L vacuum pump, 24pcs T shelf, 24pcs rubber valves. This type can be customized for your request Freeze temperature -50 C -80 C <15Pa 3kg/24h Freeze-dry area 0.12m 2 Power supply Machine size (mm) Character L380xW500xH340 FDL-18N-70-Series, Floor Freeze Dryers 220V 50Hz 800W L500xW500xH750 Big cold tray hole, with sample pre-freeze, stainless 304# cold tray, no pipe in cold tray, anti rust international standard interface to pump FDL-18N-70: -70 C lyophilizer(freeze-dryer) 108 FDL-18N-70-NH FDL-18N-70-BA FDL-18N-70-TD FDL-18N-70-8M FDL-18N-70-TD-MM Heat Without heating Basic type Top-down stoppering Heating function No Yes Freeze temperature < -70 C <13Pa Multi-manifolds (8 manifolds) Top-down stoppering & Multi-manifolds Freeze-dry area 0.27m 2 0.18 0.11 0.18 0.11 Tray load capacity 2.7L 1.8L 1.1L 1.8L 1.1L 6kg/24h Sample tray Φ200mm x6 Φ200mm x4 Φ200mm x3 Φ200mm x4 Φ200mm x3 Power supply Machine size (mm) 220V 50Hz 1800W L540xW640xH920 MRC.VER.04-5.12

FREEZE DRYERS F FD-Series Automatic Programmable Control System: From drying to defrosting, userfriendly programmable controls enable you to start runs quickly & the microprocessor controls different ramping & holding segments to meet different temp. protocols. Heated Drying system: By programmable controlling temp. by forceful circulation of the heat medium of shelf inside, it obtain a further precise distribution of temperatures. Pre-freeze system: The chamber pre-freezes sample to save money and time, eliminating the need for a separate freezer and product transfer. Defrosting system: Automatically defrosting system is available for ice condenser when defrosting is necessary. Vacuum Backfilling System: As far as the permanent preservation of the sample desiccation is concerned it protects a sample by inserting sterile nitrogen gas with back filling system for preventing contamination of the sample. Safety stoppering System: For the purpose of permanent preservation of a sample after freeze of drying, the stopper system, which seals under a vacuum state, consists an option that installs moving guides shelves delicately & that has a function to seal safely & precisely using a rotating sealing device. Automatic Purge System, It is equipped with an automated purge system to protect samples by preventing of counter-flow of vacuum pump oil. Compressor delayed start function to minimize any damage to compressor. 1.5 km far remote control system. FD5-3 FD8-3 FD5-4 FD8-4 FD5-5 FD8-5 FD5-6 FD8-6 FD5-8 FD8-8 FD5-10 FD8-10 FD5-12 FD8-12 FD5-15 FD8-15 FD5-19 FD8-19 FD5-25 FD8-25 Compressor (-58 C) 7/8HP 7/8HP 1HP 1HP 1HP 1.5HP 1.5HP 2HP 2HP 3HP Compressor (-86 C) 2x7/8HP 2x7/8HP 2x1HP 2x1HP 2x1HP 2x1.5HP 2x1.5HP 2x2HP 2x2HP 2x3HP Max. ice capacity 3L 4L 5L 6L 8L 10L 12L 15L 19L 25L Ice condenser performance 2L/24h 3L/24h 3.5L/24h 4.5L/24h 5.5L/24h 8L/24h 10L/24h 12L/24h 14L/24h 20L/24h Ice condenser Ult-temp -58 C Ice condenser Ult-temp -86 C Pump suction capacity 120L 120L 120L 120L 120L 200L 200L 200L 250L 340L Controller B T P Pump Ult-pressure 2x10-4 Torr Deforsting system Hot gas solenoid system or heater deforsting system Gross weight 70/123 70/123 70/123 123 123 123 123 150 150 150 Bench-top/vertical electrical requirement bench-top/ vertical bench-top/ vertical bench-top/ vertical vertical vertical vertical vertical vertical vertical vertical 220V, 50/60Hz single phase T-Controller 2 drying modes: automatic & manual. Automatic Purge System. Defrosting System. Compressor delayed start function to minimize any damage to compressor. It is equipped with an automatic purge system to protect samples by preventing of counter-flow of vacuum pump oil. Build-in computer and LCD touch screen program controls 5000 Memories. Monitoring system, monitoring vacuum pressure, ice condenser temperature and sample temperature. Documentation system, data saves per minute, continue 730 days and 526 memories, with a serial communication module.(optional). 1.5km far remote control system, easy to monitor and control (optional). Temperature and vacuum calibration. Alarming function. Vacuum Backfilling System(optional). power on interface manual mode interface automatic mode interface freeze drying data history data of cooling well history curve of cooling well pump testing function calibration program 109

F FREEZE DRYERS B-Controller Two drying modes: automatic and manual. Automatic purge system, to protect samples by preventing of counter-flow of vacuum pump oil. Defrosting system. Compressor delayed start function to minimize any damage to compressor. Monitoring system, monitoring vacuum pressure, ice condenser temperature & sample temperature (option). Vacuum backfilling system. APCS-Automatic program control system (optional) mode interface program memory function monitoring samples s, shelves & cooling well s temp. monitoring freeze drying data drying controlling diagram drying curve of cooling temp. pressure curve shelf temp. curve sample A temp. curve password signature encryption P-Controller Two drying modes: automatic and manual. Automatic Purge System. Defrosting system. Compressor delayed start function to minimize any damage to compressor. Automatic purge system protects samples by preventing of counter-flow of vacuum pump oil. Build-in computer and LCD touch screen program control, 5000 Memories. Monitoring system, monitoring vacuum pressure, ice condenser temperature and sample temperature. Documentation system, data saves per minute, continue 730 days and 5,260,000 memories, with a serial communication module(optional). 1.5km far remote control system, easy to monitor and control (optional). Temperature and vacuum calibration. Alarming function. Vacuum Backfilling System(optional). Simulates industry freeze dryer, realizing program control. APCS fully automatic control software from prepreezing to defrosting,digital signature encryption (optional). Preset shelf temperature, obtained the eutectic temperature, the triple point temperature, freeze-drying curve. manual mode interface automatic mode interface self-programming curve of control temp. & pressure history data program storage & documentation 110 freeze-drying data calibration program curve of shelf temp. curve of sample temp.

FREEZE DRYERS F Accessories: 1. Drying Chambers Clear Drying Chamber CDC18x06/H CDC18x06 / CDC18x06H Shelf diameter 23CM Tray diameter 18CM Number of shelf 6 Amount of 7ml serum bottle 6x50=300 Explanation: CDC: Clear Drying Chamber 06: number of shelves 23: shelf diameter 23cm H: heated shelves, displaying the curve 2. Manifold MF52 MF104 MF16 Description 52-Port manifold for lyophilizing small samples in vials 104-Port manifold for lyophilizing small samples in vials 16-Port manifold for lyophilizing smaller in vials Clear Stoppering Chamber &Valves CSC18x03x12/H Shelf diameter Tray diameter 3. Centrifugal vacuum concentrator and freeze fryer with centrifugal vacuum concentrator Capacity R-Round bottom F-Flat bottom 10ml Capacity 50 ml CF050R, CF050F 15ml 100ml CF100R, CF100F 20ml 250ml CF250R, CF250F 30ml 500ml CF500R, CF500F 50ml Explanation: 50: Capacity 50ml flask F: Flat bottom R: Round bottom Explanation: 02: 2ml Serum bottle 2ml 5ml 7ml CSC18x03x12 / CSC18x03x12H CVC2000 23CM 18CM Number of shelf 6 Number of flask 12 Amount of 7ml serum bottle 3x50=150 MF24 24-Port manifold for lyophilizing smaller flasks manifolds 4. Flasks: 5. Serum Bottles: MRC.VER.02-11.10 Clear Drying Chamber &Valves CDC18x06x12/H CDC18x06x12 / CDC18x06x12H Shelf diameter 23CM Tray diameter 18CM Number of shelf 6 Number of flask 12 Amount of 7ml serum bottle 6x50=300 Explanation: 06: number of shelves CDC: Clear Drying Chamber 12: number of flask 23: shelf diameter 23cm H: heated shelves, displaying the curve Explanation: S: Stoppering Generally the freeze dyer body connect 1 or 2 manifords, more external groups of manifold are available with specials external vacuum stand, each external group includes 3 Freeze dryer with build in centrifugal vacuum concentrator Freeze dryer with separate centrifugal vacuum concentrator SB02 SB05 SB07 SB10 SB15 SB20 SB30 SB50 111