PCI-SIG ENGINEERING CHANGE NOTICE



Similar documents
Programming Interface. for. Bus Master IDE Controller. Revision 1.0

Intel PCI and PCI Express*

Phoenix Technologies Ltd.

Errata for the PCI Express Base Specification Revision 3.0

Hot and Surprise Plug Recommendations for Enterprise PCIe Switches in the Data Center (Short Form)

PCI Express 2.0 SATA III RAID Controller Card with Internal Mini-SAS SFF-8087 Connector

PCI-SIG ENGINEERING CHANGE NOTICE

Intel Ethernet and Configuring Single Root I/O Virtualization (SR-IOV) on Microsoft* Windows* Server 2012 Hyper-V. Technical Brief v1.

The Evolution of Microsoft SQL Server: The right time for Violin flash Memory Arrays

The Bus (PCI and PCI-Express)

SPC BENCHMARK 1C FULL DISCLOSURE REPORT SEAGATE TECHNOLOGY LLC IBM 600GB 10K 6GBPS SAS 2.5" G2HS HYBRID SPC-1C V1.5

PCIe SATA 6G Raid Card

Secure SCADA Communication Protocol Performance Test Results

EHCI: Enhanced Host Controller Interface For USB 2.0

SPC BENCHMARK 1/ENERGY EXECUTIVE SUMMARY IBM CORPORATION IBM FLASHSYSTEM 840 SPC-1/E V1.14

Gigabit Ethernet Packet Capture. User s Guide

Power efficiency and power management in HP ProLiant servers

README.TXT

HP ProCurve Identity Driven Manager 3.0

Voice Over IP Per Call Bandwidth Consumption

Networking Virtualization Using FPGAs

PEX 8748, PCI Express Gen 3 Switch, 48 Lanes, 12 Ports

Global Headquarters: 5 Speen Street Framingham, MA USA P F

Intel Ethernet Switch Load Balancing System Design Using Advanced Features in Intel Ethernet Switch Family

PCI IDE Controller. Specification. Revision 1.0

Know your Cluster Bottlenecks and Maximize Performance

Storage Architectures. Ron Emerick, Oracle Corporation

Installation Guide. RAID 5 esata 3Gbps 2 external port Low profi le PCI Express card. GICe702S3R5W6 PART NO. M0557


IP videoconferencing solution with ProCurve switches and Tandberg terminals

5 means to write it as a product something times something instead of a sum something plus something plus something.

PCI-SIG ENGINEERING CHANGE NOTICE

Performance of STAR-System

Intel Solid State Drive Toolbox

Capitalizing on Smarter and Faster Insight with Flash

README.TXT

VegaStream Information Note Considerations for a VoIP installation

End-to-end management

PCI-SIG SR-IOV Primer. An Introduction to SR-IOV Technology Intel LAN Access Division

Accelerating Data Compression with Intel Multi-Core Processors

Storage node capacity in RAID0 is equal to the sum total capacity of all disks in the storage node.

GPT hard Disk Drives. For HP Desktops. Abstract. Why GPT? April Table of Contents:

HP Remote Support Software Manager

SPC BENCHMARK 1 FULL DISCLOSURE REPORT EMC CORPORATION EMC VNX8000 SPC-1 V1.14. Submitted for Review: July 30, 2015 Submission Identifier: A00159

PCI-SIG ENGINEERING CHANGE REQUEST

SPC BENCHMARK 1C FULL DISCLOSURE REPORT SEAGATE TECHNOLOGY LLC IBM 600GB 10K 6GBPS SAS 2.5" SFF SLIM-HS HDD SPC-1C V1.5

File System & Device Drive. Overview of Mass Storage Structure. Moving head Disk Mechanism. HDD Pictures 11/13/2014. CS341: Operating System

BLUETOOTH SERIAL PORT PROFILE. iwrap APPLICATION NOTE

MCA Enhancements in Future Intel Xeon Processors June 2013

Datacenter Efficiency

Brainlab Node TM Technical Specifications

The SATA II PCIe RAID is an ultra high-speed two channel Serial ATA Generation II RAID controller for use in PCI Express enabled systems.

Configuring HP Elite, EliteBook, and Z220 systems for Intel Smart Response Technology

Platform Level Data Model (PLDM) for Platform Monitoring and Control Specification

Hardware Sizing and Bandwidth Usage Guide. McAfee epolicy Orchestrator Software

Intel Solid State Drive Toolbox

AT&T Connect Video Conferencing Functional and Architectural Overview. v9.5 October 2012

DIABLO TECHNOLOGIES MEMORY CHANNEL STORAGE AND VMWARE VIRTUAL SAN : VDI ACCELERATION

System Requirements - filesmart

SPC BENCHMARK 1 FULL DISCLOSURE REPORT IBM CORPORATION IBM SYSTEM STORAGE SAN VOLUME CONTROLLER V6.2 SPC-1 V1.12

Connectivity and Communications

Virtualization of the MS Exchange Server Environment

Chapter 3 Software Installation

LENORD. +BAUER... automates motion. Fieldbus connection absolute encoders CANopen. Reference. Communication profile DS-301 Device profile DS-406

HP 128 GB Solid State Drive (SSD) *Not available in all regions.

Standard Screen Current Alarm Display. Sample Screen Manual. Mitsubishi Electric Corporation

ESPA Nov 1984 PROPOSAL FOR SERIAL DATA INTERFACE FOR PAGING EQUIPMENT CONTENTS 1. INTRODUCTION 2. CHARACTER DESCRIPTION

EEPROM PROGRAMMING FOR PCIe UARTs

4 Port PCI Express 2.0 SATA III 6Gbps RAID Controller Card with HyperDuo SSD Tiering

PCI Express SATA / esata 6Gb/s RAID Card User Manual

A Brief Tutorial on Power Management in Computer Systems. David Chalupsky, Emily Qi, & Ilango Ganga Intel Corporation March 13, 2007

BUS 101. Information Systems Presentation. Dr. Dave Croasdell Dr. Chad Anderson

HP 80 GB, 128 GB, and 160 GB Solid State Drives for HP Business Desktop PCs Overview. HP 128 GB Solid State Drive (SSD)

3 Port PCI Express 2.0 SATA III 6 Gbps RAID Controller Card w/ msata Slot and HyperDuo SSD Tiering

An Overview of Flash Storage for Databases

MS Exchange Server Acceleration

IMPRESSION COUNTING CONTENTS. in HP Web Jetadmin

INSTRUCTION MANUAL MONITOR REDUCE SAVE ENERGY MANAGEMENT SOFTWARE ENERGY MANAGEMENT SOFTWARE

Type 2 Tag Operation Specification. Technical Specification T2TOP 1.1 NFC Forum TM NFCForum-TS-Type-2-Tag_

We Energies Electric Rates

HP SkyRoom Frequently Asked Questions

CimTrak Technical Summary. DETECT All changes across your IT environment. NOTIFY Receive instant notification that a change has occurred

Preemptive security solutions for healthcare

Navigating Endpoint Encryption Technologies

PCI-to-PCI Bridge Architecture Specification. Revision 1.1

PCI-SIG Trademark and Logo Usage Guidelines

2. THE PCI EXPRESS BUS

How to Configure Intel Ethernet Converged Network Adapter-Enabled Virtual Functions on VMware* ESXi* 5.1

Implementing Multi-channel DMA with the GN412x IP

Bus Master Performance Demonstration Reference Design for the Xilinx Endpoint PCI Express Solutions

Certification: HP ATA Servers & Storage

Accelerating Microsoft Exchange Servers with I/O Caching

PCI Express High Performance Reference Design

Online Account Opening Customer FAQs

Fast Arithmetic Coding (FastAC) Implementations

How To Manage Inventory On Q Global On A Pcode (Q)

4 Channel 6-Port SATA 6Gb/s PCIe RAID Host Card

Network administrators must be aware that delay exists, and then design their network to bring end-to-end delay within acceptable limits.

Procedure for DAM Testing 24 Hour Energy Star DAM Power Consumption test procedure Version 1.3, 13 April 2010

HP 80 GB, 128 GB, and 160 GB Solid State Drives for HP Business Desktop PCs Overview. HP 128 GB Solid State Drive (SSD)

Transcription:

PCI-SIG ENGINEERING CHANGE NOTICE TITLE: Dynamic Power Allocation DATE: May 24, 2008 AFFECTED DOCUMENT: PCI Express Base Specification version 2.0 SPONSOR: Intel Corporation, Hewlett-Packard, IBM Part I 1. Summary of the Functional Changes DPA (Dynamic Power Allocation) extends existing PCIe device power management to provide active (D0) device power management substates for appropriate devices, while comprehending existing PCIe PM Capabilities including PCI-PM and Power Budgeting. 2. Benefits as a Result of the Changes DPA complements on-going industry efforts to optimize component and platform power management to meet new customer and regulatory operating requirements. DPA provides a capability so that all Endpoint Functions can have a mechanism for the dynamic allocation of power. DPA is applicable to appropriate PCIe Endpoint Functions. 3. Assessment of the Impact DPA is optional normative functionality, applicable to appropriate Endpoint Functions 4. Analysis of the Hardware Implications Implementations that support this mechanism must implement the DPA Capability and associated ability to dynamically adjust Endpoint Function power utilization. 5. Analysis of the Software Implications The DPA Capability enables a method for software to discover and actively manage Endpoint Function power usage. Power management policies used to determine which power state to operate at are outside the scope of the PCI-SIG. Page 1

Part II Detailed Description of the change Add Section 6.x 6.x Dynamic Power Allocation (DPA) Capability A common approach to managing power consumption is through a negotiation between the device driver, operating system, and executing applications. Adding Dynamic Power Allocation for such devices is anticipated to be done as an extension of that negotiation, through software mechanisms that are outside of the scope of this specification. Some devices do not have a device specific driver to manage power efficiently. The DPA Capability provides a mechanism to allocate power dynamically for these types of devices. DPA is optional normative functionality applicable to Endpoint Functions that can benefit from the dynamic allocation of power and do not have an alternative mechanism. The DPA Capability enables software to actively manage and optimize Function power usage when in the D0 state. DPA is not applicable to power states D1-D3 therefore the DPA Capability is independently managed from the PCI-PM Capability. DPA defines a set of power substates, each of which with an associated power allocation. Up to 32 substates [0..31] can be defined per Function. Substate 0, the default substate, indicates the maximum power the Function is ever capable of consuming. Substates must be contiguously numbered from 0 to Substate_Max, as defined in section 7.x.2. Each successive substate has a power allocation lower than or equal to that of the prior substate. For example, a Function with four substates could be defined as follows: 1. Substate 0 (the default) defines a power allocation of 25 Watts. 2. Substate 1 defines a power allocation of 20 Watts 3. Substate 2 defines a power allocation of 20 Watts 4. Substate 3 defines a power allocation of 10 Watts. When the Function is initialized, it will operate within the power allocation associated with substate 0. Software is not required to progress through intermediate substates. Over time, software may dynamically configure the Function to operate at any of the substates in any sequence it chooses. Software is permitted to configure the Function to operate at any of the substates before the Function completes a previously initiated substate transition. On the completion of the substate transition(s) the Function must compare its substate with the configured substate. If the Function substate does not match the configured substate, then the Function must begin transition to the configured substate. It is permitted for the Function to dynamically alter substate transitions on Configuration Requests instructing the Function to operate in a new substate. In the prior example, software can configure the Function to transition to substate 4, followed by substate 1, followed by substate 3, and so forth. As a result, the Function must be able to transition between any substates when software configures the associated control field. Page 2

The Substate Control Enabled bit provides a mechanism that allows the DPA Capability to be used in conjunction with the software negotiation mechanism mentioned above. When Set, power allocation is controlled by the DPA Capability. When Clear, the DPA Capability is disabled, and the Function is not permitted to directly initiate substate transitions based on configuration of the Substate Control register field. At an appropriate point in time, software participating in the software negotiation mechanism mentioned above clears the bit, effectively taking over control of power allocation for the Function. It is required that the Function respond to Configuration Space accesses while in any substate. At any instant, the Function must never draw more power than it indicates through its Substate Status. When the Function is configured to transition from a higher power substate to a lower power substate, the Function s Substate Status must indicate the higher power substate during the transition, and must indicate the lower power substate after completing the transition. When the Function is configured to transition from a lower power substate to a higher power substate, the Function s Substate Status must indicate the higher power substate during the transition, as well as after completing the transition. Due to the variety of applications and the wide range of maximum power required for a given Function, the transition time required between any substates is implementation specific. To enable software to construct power management policies (outside the scope of this specification), the Function defines two Transition Latency Values. Each of the Function substates associates its maximum Transition Latency with one of the Transition Latency Values, where the maximum Transition Latency is the time it takes for the Function to enter the configured substate from any other substate. A Function is permitted to complete the substate transition faster than the maximum Transition Latency for the substate. 6.x.1 DPA Capability with Multi-Function Devices It is permitted for some or all Functions of a multi-function device to implement a DPA Capability. The power allocation for the multi-function device is the sum of power allocations set by the DPA Capability for each Function. It is permitted for the DPA Capability of a Function to include the power allocation for the Function itself as well as account for power allocation for other Functions that do not implement a DPA Capability. The association between multiple Functions for DPA is implementation specific and beyond the scope of this specification. Page 3

Add Section 7.x 7.x Dynamic Power Allocation (DPA) Capability The DPA Capability structure is shown in Figure 7-xx below 31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 Next Capability Offset Cap Version PCIe Extended Cap ID 000h DPA Control Register DPA Capability Register DPA Latency Indicator Register DPA Power Allocation Array DPA Status Register 004h 008h 00Ch 010h (sized by number of substates) up to 02Ch Figure 7-xx Dynamic Power Allocation Capability Structure 7.x.1. DPA Extended Capability Header (Offset 00h) 31 20 19 16 15 0 Next Capability Offset PCI Express Extended Capability ID Capability Version Figure 7-xx DPA Extended Capability Header Table 7-xx DPA Extended Capability Header 15:0 PCI Express Extended Capability ID This field is a PCI-SIG defined ID number that indicates the nature and format of the Extended Capability. PCI Express Extended Capability ID for the DPA Extended Capability is 0016h. 19:16 Capability Version This field is a PCI-SIG defined version number that indicates the version of the Capability structure present. Must be 1h for this version of the specification. 31:20 Next Capability Offset This field contains the offset to the next PCI Express Extended Capability structure or 000h if no other items exist in the linked list of capabilities. Page 4

7.x.2. DPA Capability Register (Offset 04h) 31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 Xlcy1 Xlcy0 RsvdZ PAS RsvdZ Tlunit RsvdZ Substate_Max Figure 7-xx DPA Capability Register Table 7-xx DPA Capability Register 4:0 Substate_Max: Value indicates the maximum substate number, which is the total number of supported substates minus one. A value of 00000b indicates support for one substate. 9:8 Transition Latency Unit (Tlunit): A substate s Transition Latency Value is multiplied by the Transition Latency Unit to determine the maximum Transition Latency for the substate. Defined encodings are 00b 1ms 01b 10ms 10b 100 ms 11b Reserved 13:12 Power Allocation Scale (PAS): The encodings provide the scale to determine power allocation per substate in Watts. The value corresponding to the substate in the Substate Power Allocation Register is multiplied by this field to determine the power allocation for the substate. Defined encodings are 00b 10.0x 01b 1.0x 10b 0.1x 11b 0.01x 23:16 Transition Latency Value 0 (Xlcy0): This value is multiplied by the Transition Latency Unit to determine the maximum Transition Latency for the substate 31:24 Transition Latency Value 1 (Xlcy1): This value is multiplied by the Transition Latency Unit to determine the maximum Transition Latency for the substate Page 5

7.x.3. DPA Latency Indicator Register (Offset 08h) 31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 Transition Latency Indicator Bits Figure 7-xx DPA Latency Indicator Register Table 7-xx DPA Latency Indicator Register Substate_Max:0 Transition Latency Indicator Bits: Each bit indicates which Transition Latency Value is associated with the corresponding substate. A value of 0b indicates Transition Latency Value 0; a value of 1b indicates Transition Latency Value 1. All other bits Reserved RsvdP 7.x.4. DPA Status Register (Offset 0Ch) 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 RsvdZ RsvdZ Substate Status Substate Control Enabled Figure 7-xx DPA Status Register Table 7-xx DPA Status Register 4:0 Substate Status: Indicates current substate for this Function Default is 00000b 8 Substate Control Enabled: Used by software to disable the Substate Control field in the DPA Control register. Hardware sets this bit following a Conventional Reset or FLR. Software clears this bit by writing a 1b to it. Software is unable to set this bit directly. When this bit is Set, the Substate Control field determines the current substate. When this bit is Clear, the Substate Control field has no effect on the current substate. Default value is 1b. RW1C Page 6

7.x.5. DPA Control Register (Offset 0Eh) 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 RsvdP Substate Control Figure 7-xx DPA Control Register Table 7-xx DPA Control Register 4:0 Substate Control: Used by software to configure the Function substate. Software writes the substate value in this field to initiate a substate transition. When the Substate Control Enabled bit in the DPA Status register is Set, this field determines the Function substate. When the Substate Control Enabled bit in the DPA Status register is Clear, this field has no effect the Function substate. Default value is 00000b. RW 7.x.6. DPA Power Allocation Array 7 6 5 4 3 2 1 0 Substate Power Allocation Register (0) Substate Power Allocation Register (Substate_Max) 010h + 0 010h + Substate_Max Figure 7-xx DPA Power Allocation Array Each Substate Power Allocation Register indicates the power allocation value for its associated substate. The number of Substate Power Allocation Registers implemented must be equal to the number of substates supported by Function, which is Substate_Max plus one. Table 7-xx Substate Power Allocation Register (0 to Substate_Max) 7:0 Substate Power Allocation: The value in this field is multiplied by the Power Allocation Scale to determine power allocation in Watts for the associated substate. Page 7