ACOUSTIC PERFORMANCES OF AN HEMIANECHOIC ROOM FOR ELECTROMAGNETIC COMPATIBILITY TESTS



Similar documents
Sound Power Measurement

Tools for building acoustics design and experimental performances

[see Figure 3 below] Ferrite tile walls and ceiling RF Absorber parcel walls and ceiling Removable floor section to make fully anechoic

Measurement of RF Emissions from a Final Coat Electronics Corrosion Module

40 Years of experience in EMC testing

AN003. Evaluation of Anechoic Chambers For EMC Measurements Using A CNE. Overview. CNE III 9kHz to 2GHz Conducted and radiated output

THE MARIA REGINA DELLA PACE CHURCH IN PERUGIA: ACOUSTIC MEASUREMENTS AND CORRECTION DESIGN

Relationship between Sound Pressure and Sound Power Levels

Acoustic analysis by computer simulation for building restoration

An extended EMC study of an electrical powertrain for transportation systems

DQGDQDXGLWRULXP

Airborne Sound Insulation

PAGE 2. Figure 1: Difference between PWL ins and SPL 1m

Optiffuser. High-performance, high bandwidth lightweight 1D diffuser.

Separation of power and information technology cabling

EMC STANDARDS STANDARDS AND STANDARD MAKING BODIES. International. International Electrotechnical Commission (IEC)

Ferroxcube. For more information on Product Status Definitions, see page Sep CBW625

RX-AM4SF Receiver. Pin-out. Connections

EMC Basics. Speaker : Alain Lafuente. Alain.lafuente@we-online.com

Tuning a Monopole Antenna Using a Network Analyzer

A NEW PYRAMID TRACER FOR MEDIUM AND LARGE SCALE ACOUSTIC PROBLEMS

Fundamentals of Acoustics & Practical HVAC Design Considerations. Demir Doken Acoustic Engineer

How To Make A Supply Air Ceiling

INTER-NOISE DECEMBER 2006 HONOLULU, HAWAII, USA

Panashield, Inc. Facility Solutions For Global Electromagnetic Compatibility

Building Design for Advanced Technology Instruments Sensitive to Acoustical Noise

Validation of the pyramid tracing algorithm for sound propagation outdoors: comparison with experimental measurements

Evaluating Cell Phone and Personal Communications Equipment and their EMC Effects on Automotive Audio and In-Cabin Modules

Characterization of acoustics in open offices - four case studies

THE ACOUSTICS OF ROOMS

THE ACOUSTICS OF THE "NUOVO TEATRO COMUNALE" IN CAGLIARI

VIRTUAL SPACE 4D PROJECT: THE ROOM ACOUSTICAL TOOL. J. Keränen, P. Larm, V. Hongisto

Verification of the accuracy of the Pyramid Tracing algorithm by comparison with experimental measurements of objective acoustic parameters

An Experimental Study of the Sound Insulation Performance and Sound Defect Using Sound Intensity According to the Composition of Balcony Windows

Cellular Wireless Antennas

A Study of RF Absorber for Anechoic Chambers Used in the Frequency Range for Power Line Communication System

Acoustic design of schools: performance standards. From 2003 to 2014: a brief guide to the changes in BB 93. by Jack Harvie-Clark, 9th January 2015

Aircraft cabin noise synthesis for noise subjective analysis

VIPAC ENGINEERS & SCIENTISTS

Subject: Glenair MIL-PRF Conduit Surface Transfer Impedance Test

Uncertainty evaluations in EMC measurements

Acoustics of indoor sports halls and gymnasia

Acoustic design with wall acoustic solutions

Exhaust noise control case study for 2800 class locomotive

Acoustical Design Guidelines for HVAC Systems in Schools

General Thoughts on Generator Set - Acoustic Solutions & Noise Control

Trans Bay Cable Project (400 MW) Preliminary Audible Noise Study

Wardle Storeys. Reducing Rain Noise on Profiled Metal Roofing Systems Using DEDPAN DS2020 RDV

Acoustical proprieties of light brick walls and its effects on flanking transmission

Investigation of the Calibration Procedure from CISPR 25, Annex B, for use with Vehicle Component Testing.

RF data receiver super-reactive ASK modulation, low cost and low consumption ideal for Microchip HCS KEELOQ decoder/encoder family. 0.

FDTD Analysis of Site Free Space VSWR in Test Site Used for Disturbance Measurement above 1 GHz

The Use of Computer Modeling in Room Acoustics

Dual Chamber Temporary External Pacemaker

Workbench EMC Measurements by Henry W. Ott Henry Ott Consultants

Lightweight Partition Design for Residential and Commercial Buildings

Acoustic Terms, Definitions and General Information

Shielding Effectiveness Test Method. Harbour s LL, SB, and SS Coaxial Cables. Designs for Improved Shielding Effectiveness

Noise Control Solutions For Standby Power Generators

Minimizing noise levels so future engineers can focus Classroom Acoustic Technical Reference Guide

Design of an Acoustic Anechoic Chamber for Application in Hearing Aid Research

Compression and Distortion. Low Frequency Section

Active noise control in practice: transformer station

is the power reference: Specifically, power in db is represented by the following equation, where P0 P db = 10 log 10

Radio Frequency Interference (RFI) Shielding Principles

DVT913 TV CHANNEL CONVERTER

ENGINEERING DATA. Fan Sound & Sound Ratings

NUMERICAL ANALYSIS FOR THE IMPROVEMENT OF A SPECIAL REVERBERATION TEST ROOM

The Role of Acoustics in Curtain Wall Design:

Repelling effect on mice and rats

CABLES CABLES. Application note. Link Budget

ST Series POWER SUPPLIES USER INSTRUCTIONS

Direct and Reflected: Understanding the Truth with Y-S 3

Engineering Method of Sound Power Determination for Marine Engines

The Effects of Gaps in Ferrite Tiles on Both Absorber and Chamber Performance

Pre-Compliance Test Method for Radiated Emissions of Automotive Components Using Scattering Parameter Transfer Functions

Development and optimization of a hybrid passive/active liner for flow duct applications

Acoustical Design for Concert Hall in the Science and Art Centre of Xiamen University

RICHARD T ELL ASSOCIATES,INC.

Affordable Sports Halls

MINIMUM USAGE OF FERRITE TILES IN ANECHOIC CHAMBERS

1701/22 FieldMonitor Management Interface Module

Drayton Digistat +2RF/+3RF

Mitel DECT Base Stations

Noise. CIH Review PDC March 2012

MEASUREMENT SET-UP FOR TRAPS

R&S R-Line Compact Test Chamber Precise measurements of radiated emissions of wireless terminals 800 MHz to 18 GHz

An octave bandwidth dipole antenna

OMNIYIG. .5 TO 2 GHz, 1 TO 4 GHz, 6 to 18 GHz Thin Film YIG-TUNED OSCILLATORS OUTLINE DIMESIONS MOUNTING SURFACE GND +15V + TUNE - HTR HTR

Pyramid Tracing vs. Ray Tracing for the simulation of sound propagation in large rooms. Abstract 1. Introduction to the two algorithms

WTW SWANTM. Linear slot air diffusers of wall-to-wall design for ceilings

Draft ETSI EN V1.2.1 ( )

Generic - Hearing Loop - (AFILS) U.S. System Specification

ISS ACOUSTIC REQUIREMENTS AND TESTING DOCUMENT FOR ISS NON-INTEGRATED EQUIPMENT

Microwave Absorbers. Absorber for Microwave and Millimeter Wave Test Chambers S SYSTEMS C CHAMBERS A ANTENNAS SW SOFTWARE

Rated Power(W) 8W 2. EG-LED W 3. EG-LED W

As a minimum, the report must include the following sections in the given sequence:

4.4 WAVE CHARACTERISTICS 4.5 WAVE PROPERTIES HW/Study Packet

How To Control Noise In A C7 Data Center Server Room

B. Equipment shall be furnished and installed as specified. No substitutions will be allowed.

Transcription:

ACOUSTIC PERFORMANCES OF AN HEMIANECHOIC ROOM FOR ELECTROMAGNETIC COMPATIBILITY TESTS Franco Cotana, Federico Rossi, Andrea Nicolini Università degli Studi di Perugia, Dipartimento di Ingegneria Industriale Via G. Duranti, 67 065 Perugia, Italia e-mail address of lead author: frossi@unipg.it Abstract An investigation on the acoustical characteristics of an electromagnetic hemianechoic room is here proposed. The research has been carried out within an agreement between the Perugia University Acoustic Laboratory and Angelantoni Industrie S.p.a. Angelantoni Industrie hemianechoic room has been investigated. The room has been created for electromagnetic compatibility tests. It is fully insulated from the outside environment and it guarantees more than 0 KOhms of insulating power. A hybrid solution has been chosen for the anechoic lining of walls and ceiling; the quiet zone is covered by 4 cones coupled to ferrite tiles whereas the remaining parts are covered with 6 cones. No fixed anechoic insulation is on the floor (hemianechoic type). An acoustic measurement campaign has been carried out in order to verify if the investigated room is characterized also by high acoustic hemianechoic performances. Measurements have been led according to ISO 745. Measurement results have shown that the investigated room, differently from the acoustic typical hemianechoic rooms, accords to ISO 745 only for 5-0000 Hz frequency range and for a.5 m radius hemispheric surface. INTRODUCTION The European Directive 89/6/EEC on Electromagnetic Compatibility is now operative all over Europe []. Since electronic components have been widely used practically in any field, new safety issues are becoming more and more urgent: among

them, for example, the need to operate any electronic appliance without causing interference to nearby systems or without being disturbed by other equipment. In this context, anechoic rooms represent the ideal environment where to evaluate electromagnetic interference and where to perform qualification tests aimed at guaranteeing that products comply with the European standards. Anechoic and hemianechoic rooms for electromagnetic compatibility tests are often equipped by absorbing coning surfaces; these elements are often realized by sound absorbing material. Thus, an hemianechoic room for electromagnetic compatibility tests may have also good sound absorbing properties. This paper deals with an experimental investigation on an hemianechoic room for electromagnetic compatibility test. In particular, the room acoustic characteristics have been studied. A measurement campaign has been carried out according to ISO 745 []. Measurement results have shown that the investigated room may be considered an hemianechoic room for acoustic tests only for frequencies over 00 Hz and under.5 m radius measurement surfaces. THE ANECHOIC ROOM The investigated room is an anechoic room for electromagnetic compatibility tests which has been realized by Angelantoni Industrie S.p.a., an Italian factory which uses the room to perform quality and safety tests on their wide range of products. The research has been carried out within an agreement between the Perugia University Acoustic Laboratory and Angelantoni Industrie S.p.a. The room is completely electromagnetically insulated from the external environment; besides, the hemianechoic room allows the repeatability of the tests and the result objectiveness thanks to the high degree of electromagnetic absorption of the fields produced inside. Room dimensions are 6x9x6.5 m. It is grounded on one point only and it guarantees more than 0 KOhms of insulating power. The attenuation levels of the shielded room are indicated in Table. Table : room attenuation levels Field Frequency Attenuation H 00 khz > db H MHz > 00 db E 00 khz > db E MHz > 00 db E 0 MHz > 00 db E 00 MHz > 00 db PW 400 MHz > 00 db PW 000 MHz > 00 db PW 0000 MHz > 00 db The hemianechoic room is equipped with the following openings:

- a double-wing main entrance door (4x.5 m) for the tests instrumentation movement; - a single-wing service door (.x m) for the access of the operators; - port holes for connectors for power supply and air-conditioner connections. The embossed aluminium plate floor can support up to 000 kg concentrated on four points of a square whose side is 0 cm wide. An opening in the middle of the floor is connected to a drain hole and allows the discharge of accidental water leaks from the equipment under test. A hybrid solution has been chosen for the anechoic lining of walls and ceiling; the quiet zone is covered by 4 cones coupled to ferrite tiles whereas the remaining parts are covered with 6 cones (see Figure ). No fixed anechoic insulation is needed on the floor (hemianechoic type). MEASUREMENT METHOD FOR ACOUSTIC CHARACTERIZATION A measurement campaign has been carried out according to ISO 745 []; an omni directional dodecahedral source has been placed on the floor on the room floor centre (see Figure ). Measurements have been carried out by means of Symphonie data acquisition system. A white noise sequence has been generated by the dodecahedral source driven by the data processing system. Sound pressure levels have been picked up by a G.R.A.S. microphone (model 40AR) along 5 paths not parallel to the reflecting floor (see Figure ). Measurements points have been chosen from a 50 cm distance from the noise source to the maximum available distance. Distance between two adjacent points is 0 cm for each measurement path. Figure shows some measurement phases. Figure : Measurement phases

Measured sound pressure levels have been compared to the free field ones; free field levels have been estimated by the following method: - noise source power spectrum has been evaluated by an intensimetric campaign according to ISO 964- []; - free field pressure levels have been evaluated by taking into account divergence phenomena [4]. Maximum difference between measured and free field levels have to be (according to ISO 745): - ± db for frequencies 60 Hz; - ±,0 db for [0, 5000] Hz frequency range - ±,0 db for frequencies 600 Hz. Figure : measurement paths MEASUREMENT RESULTS Global linear measured levels and the free field ones are shown in Figures and 4 relatively to each measurement path. Global linear difference is less than.5 db for each measurement path. Global linear difference and differences relative to each frequency band are sometimes negative. This fact is absurd because experimental measured levels can t be less than free field ones [4]. Negative differences occur because noise source barycentre does not coincide with the room floor centre; it is placed at an about 5 cm height from the floor. Thus, noise source may be assimilated to a dipole and destructive interferences may cause level reductions [5].

00 (a) 5,5 5 4,5 4,5 00 (b) 4,5 00 (c) Figure : global linear measured level and free field level vs source-point distance relative to (a) path ; (b) path ; (c) path

00 (d) 5,5 5 4,5 4,5 00 (e) 4,5 Figure 4: global linear measured level and free field level vs source-point distance relative to: (d) path 4; (e) path 5 ISO 745 conditions are verified within a source-centred hemispheric surface. The hemispheric surface ray value is reported in Table for each one-third octave frequency band. ISO 745 conditions are verified for the following frequency range and sourcepoint distances values: - within, m source-point distance and for frequencies 5 Hz relatively to path ; - within,0 m source-point distance and for frequencies 5 Hz relatively to path ;

- within m source-point distance and for frequencies 5 Hz relatively to path ; - within, m source-point distance and for frequencies 5 Hz relatively to path 4; - within,7 m source-point distance and for frequencies 5 Hz relatively to path 5. Table : hemispheric surface ray value which verifies the ISO 745 conditions Frequency (Hz) Hemispheric surface ray (m) 6-0 5 0,7 40, 50, 6 0,6 0,8 00 0,6 5 0,7 60 00, 50 0,8 5 400,8 500,7 60,6 0 K K,7,6 K K,8 K,7,5 K 4 K,6 5 K,8 6, K 8 K, 0 K,7 K,7 6 K,6 0 K

CONCLUSIONS Acoustics characteristics of an hemianechoic room for electromagnetic compatibility tests have been investigated. The investigated room is coated by absorbing cones coupled to ferrite tiles. A measurement campaign has been led according to ISO 745. Sound pressure levels due to an omni directional white noise source have been measured along five paths. The comparison between measured levels and free field estimated levels has shown that the investigated room is an acoustic hemianechoic room for: - frequencies 5 Hz; - within a m radius source-centred hemispherical surface. An acoustic hemianechoic room with the same dimensions of the investigated room generally accords to ISO 745 for Hz-0kHz frequency range [6]. The proposed research demonstrates that an anechoic room for electromagnetic compatibility test may be used as an acoustic anechoic room only over 5 Hz. REFERENCES [] European Directive 89/6/EEC on the approximation of the laws of the Member States relating to electromagnetic compatibility, Bruxelles, 989. [] ISO/CD 745, Acoustics. Determination of sound power levels of noise sources using sound pressure. Precision methods for anechoic and hemi-anechoic rooms, Second Committee Draft, 999 [] ISO 964-, Acoustics. Determination of sound power levels of noise sources using sound intensity. Part : measurement at discrete points, 99 [4] L.L.Beranek, Noise and Vibration Control, McGraw Hill, New York, 97 [5] A. Farina, F. Simoni, V. Tarabusi, Qualificazione acustica di camere semianecoiche mediante applicazione della metodologia prevista dalla norma ISO 745-977, Convegno Nazionale Rumore e Vibrazioni, Bologna-Modena, 9 [6] R.R.Boullosa, A.Perez Lopez, Some acoustical properties of the anechoic chamber at the Centro de Instrumentos, Universidad Nacional Autonoma de Mexico, Applied Acoustics 56, pp.99-07, 999