Section 5. 510(K) Summary. Kimberly-Clark Corporation. 2100 Winchester Road Neenah, WI 54956



Similar documents
October 28, Cavex Holland Bv Mr. Richard Woortman Manager Technical Services Fustweg 5 Haarlem, 2031CJ The NETHERLANDS

February 5, Dear Kristin Pabst,

Q(K SVJM~jPagelIof 3

GE Healthcare MAR

May 7, Tactile Systems Technology Inc Daniel Chase V.P. Engineering & Operations 1331 Tyler St NE Minneapolis, Minnesota 55413

February 22, Life Spine, Incorporated Mr. Randy Lewis General Manager 2401 West Hassell Road, Suite 1535 Hoffman Estates, Illinois 60169

Lewis Ward L.W. Ward and Associates, Inc Kirkwood Court Boulder, CO

January 12, Dear Amy Yang:

August 12, Oertli Instrumente AG Ms. Karin Rohr Head of Quality Management & Regulatory Affairs Hafnerwisenstrasse 4 CH 9442 Berneck Switzerland

(k)Suminary k

I~r it NOV SIE T AENCORE Tongue Suspension System OCE L_ August 3, (k) Summary. Appendix 3:

April 7, Acclarent, Inc. Mr. James Patrick Garvey II Sr. Manager, Regulatory Affairs 1525-B O'Brien Drive Menlo Park, CA 94025

510(k) Summary. Dentsply Implants. April 30, 2013

November 17, Nanova Biomaterials, Inc. Mr. Andrew Ritts Senior Research Scientist 3806 Mojave Ct Columbia, Missouri, 65202

November 20, Vascular Flow Technologies Ltd. Edwin Lindsay VP of QA/RA Prospect Business Centre, Gemini Cresent Dundee DD2 1TY United Kingdom

University of Texas Medical School at Houston. April 14, 2015

Simpler Implant Solutions Inc Arbutus St. Vancouver, BC V6i 3Y9. haroldbergmanl~ogmail.com Telephone Fax K080115

510(K) SUMMARY [as required by section (c)] FLIGHT 60 Ventilator 510(k) Number K IaO?2Z, JUL

May 5, Dear Mr. Courtney:

July 24, Dear Ms. Rhodes:

April 3, Dear Autumn Liu,

Ad-tech Medical Instrument Corporation. Principal Consultant Quality & Regulatory Associates, LLC. 800 Levanger Lane. Stoughton, Wisconsin 53589

kok1 UQ 510(k)J Device {Applicant 510(k) Summary (per 21 CFR (c)) OCT Applicant

2. Contact Person: Garo Mimaryan, MS., RAC 7 Technical Regulatory Affairs Specialist III 3. Phone Number: (914)

Brainreader ApS February 4, 2015 C/O Mette Munch QA Consultant Skagenvej 21 Egaa, 8250 DENMARK

(k) SUMMARY DEC

August 21, TCM Associates Ltd Mr. Iain Alligan Technical Director 3 Hillgrove Business Park Nazeing Road Essex EN9 2HB United Kingdom

March 3, Dear Ms. Alice Gong,

AW Server 510 (k) Summary of Safety and Effectiveness

DICOM Grid, Inc. January 25, Senior Consultant Biologics Consulting Group, Inc. 400 N. Washington Street, Suite 100 ALEXANDRIA VA 22314

March 20, Dear Mr. Chen:

June 9, Stryker Corporation Garry T. Hayeck, Ph.D. Senior Regulatory Affairs Specialist 2 Pearl Court Allendale, New Jersey 07401

Section 5-510(k) Summary. This document is provided in the following pages. DEC

510(k) SUMMARY APR Date: 15 th December 2008

JUN 2 6 butt. EkoSonicTM Endovascular System with Rapid Pulse Modulation

0 EC V-,) 133 Lj9a

Ultimate Concepts Inc.

SECTION 5 BARDEX TEMPERATURE-SENSING FOLEY CATHETER 510(k) SUMMARY OF SAFETY AND EFFECTIVENESS INFORMATION

FEB Mr. Gordon J. Peters Director Regulatory Compliance DocuSys, Incorporated 820 S. University Boulevard, Suite 3-H Mobile, Alabama 36609

October 29, Dear Ms. Hartnett:

510(k) Summary. Atlanti STM Abutment and AtlantisTM Crown Abutment in Zirconia for Dentsply Ankylos Implant

Dental Morelli Ltda.

May 20, Ivoclar Vivadent Ag Ms. Donna Hartnett Director Regulatory Affairs Ivoclar Vivadent, Inc. 175 Pineview Drive Amherst, New York 14228

Phoenix Thera-Lase Systems, LLC Ms. Diane Rutherford Ken Block Consulting 1201 Richardson Drive, Suite 280 Richardson, Texas 75080

EM GR.OUF DIPLOMAT. OT39?1 Company Name: (K)SUMMARY Oc. Submission Correspondent. Emergo Group, Inc. Company Address:

510(k) Summary GlobalMedia Group, LIC. MAY CONiM

J UN (k) SUMMARY AS REQUIRED BY SECTION (C) Mrs. Mitsuko Yoneyama President. Submitted by:

510(K) SUMMARY. 510(k) Number KOS'00-r

Ni Hau Industrial Co., Ltd. Ms. Lyn Chiu Sales Manager No. 15, Alley 125, Lane 318, Section 2, An Ho Road Tainan City, Taiwan 70967

,11 DSA Cable, transducer and VS3, VS4 electrode, patient connector

510(k) SUMMARY MANI Needle and Suture Pack MANI, Inc.

September 17, Keeler Instruments Inc. Mr. Eugene R. Van Arsdale Marketing Manager 459 Parkway Broomall, PA 19008

Building 6, Suite 300 RyeBrook, NY C-ontact-N~ame: --- William H-. Schofield Director of TeleHealth Operations. Signal,_Radiofrequency

SUMMARY OF SAFETY AND EFFECTIVENESS for Powered Muscle Stimulator

July 21, Dentca, Inc. c/o Mr. Claude Berthoin Denterprise International, Inc. 110 East Granada Blvd, Suite 207 Ormond Beach, Florida 32176

BMR ~131o-lvleccai Kesearcn Ltd.

sbchoi~kku.edu jeremy~sooil.com DANA Diabecare IlS Insulin Infusion pump Infusion pump Class II

51O(K) SUMMARY: Therapy family of devices.

D I Z1. 510(k) Summary. Section 5. Siemens Medical Solutions USA, Inc. Oncology Care Systems. Date Prepared: September 09,

L~l t l V~! MAY ?

510(k) Summary (c)

AgaMatrucx. NV2 21 Salem, NH oz (k) Sumnmary

September 25, Dear Ms. McCoy:

DEC The three components of the Axxent Electronic Brachytherapy System include the Controller, Balloon Applicators-BR and X-ray Source.

Dear Ms. Lucas: This letter corrects our substantially equivalent letter of February 18, 2016.

May 22, Rachel s Remedies, LLC Mrs. Rachel E. Jackson 2316 Delaware Ave. #174 Buffalo, New York 14216

MViAKIO. V.A hn2 ATTACHMENT I 610(K) SUMMARY. Submitter:

IQ Corporation c/o Harold G. Haines, Ph.D. President SEP 1 f 2002 South Florida BioAssociates, Inc SW 127h Street Miami, Florida

510(k) Summary of Safety and Effectiveness JUN Hip prosthesis

RAMSOFT BUG ,-. I"-, --I 2 N Tel: (416) Fax: (416) sales@ramsoftbiz (k) Summary

March 31, Etiometry, Inc. Richard Galgon Independent Consulting Associate Quintiles 5846 Cobblestone Lane Waunakee, Wisconsin 53597

510(k) SUMMARY. OPTION-vyM Urinary Catheter

Datrix, Inc NOV Appendix G. 510(k) Summary of Safety and Effectiveness for Datrix, Inc CardioServer ECG Management System

Manufacturing Technology, Inc.

KIZ 2,33-3 p8 ~ 510(k) Summary. As required by 21 CFR (c) 510(k) Premarket Notification Submission AFrame Digital MobileCare Monitor.

JN (k) Summary Device Identification: Device Description:

Koqo8 go. ER35 ERO-SCAN Pro Hearing Test System. 61 Martin Lane Elk Grove Village, IL Manager of Instrumentation Products

Fresenius Medical Care

MAY SECTION VIII. 510(k) SUMMARY OF SAFETY AND EFFECTIVENESS

ELASTO-GEL MANIJKAH"O"NEY JUUjj 2. fudbthsarltvl of the wound fluid, while re~leas'ing

510(k) SUMMARY JUL Otoharmonics 0 Levo 9 System

MAR (k) SUMMARY OF SAFETY AND EFFECTIVENESS (21CFR ) 1. DATE PREPARED: 4/21/2008

MAY Attachment (k) Summary 21 CER

ATLANTIS Anterior Cervical Plate System ATLANTIS Translational Plate. 510(k) Summary. February 2007

W~c f-t. MAR 2 1 2fl09SC. 5 10(k) summary TRACTION MASTERS, INC. Traction Masters, Inc. AKA: Spinetronics, LLC 9737 NW 65 PL Parkland, Florida 33076

OCT 18 20U5Ibko. a. Submitter Name: Cosmetic Dental Materials Inc. (CDM Inc.) b. Submitter Address: 812 Water St. NE Albany OR 97321

510(K) Summary K102148

DEC V,(9/azO (c 0 j

Histoacryl Flexible Topical Skin Adhesive April15, 2013

foq8 510(k) Summary fo r PAIRIETEX ~ COMPOSITE Mesh

ItP. Section I. 510(k) Summary of Safety and Effectiveness. Applicant:

Summary of Safety and Effectiveness

510(k) Summary. (508) X222 Disposable Insulin Delivery Device

March 23, Vision Quest Industries, Inc. Mr. Mohammed Ouerghi Director of QA/RA 1390 Decision Street, Suite A Vista, CA 92081

I C 5 5l v ri 510(K) SUMMARY. Prowess Panther

510(k) Summary SUBMITTER'S NAME, ADDRESS, TELEPHONE NUMBER, CONTACT PERSON, AND DATE SUMMARY PREPARED:

Medical Devices; Cardiovascular Devices; Classification of the Esophageal Thermal Regulation

Food and Drug Administration 5 10(k) Notijfication - Partial & Total Ossicular Replacement Prostheses AUG I June 30, 2006

510(k) Summary Special Premarket Notification 510(k) Section 6

r5 73~ 9/ / 510(K) Summary (K) SUMMARY

Transcription:

(a Kimberly-ClarkiCorpbration K I X0 6 a Traditional 510(k) for Kimberly-Clark Poise D Personal Lubricant IJUL 1 1 2012 Section 5. 510(K) Summary Summary of Safety and Effectiveness Information Submitter's Name: Kimberly-Clark Corporation Submiffer's Address: 2100 Winchester Road Neenah, WI 54956 Submitter's Phone No: 770-587-8083 Submitter's Fax No. 920-225-3632 Date of Preparation: February 29, 2012 Trade Name: Device Common Name: Classification Name: Classification Product Code: Regulation Number: Mailing address for regulatory correspondence: 1400 Holcomb Bridge Road Roswell, GA 30076-2199 Contact Person: Swarna Mukund Ph. D. Poise Personal Lubricant Personal Lubricant Condom NUC (Lubricant, Vaginal, Patient, Latex Compatible) 21 CFR884.5300 Regulatory Class: Class 11 Legally marketed device Durex Play Lubricant (K032124) (Marketed as Durex Play' to which equivalency ismoe claimed:moe Intended Use: Poise Personal Lubricant is a personal lubricant, for penile and/or vaginal application, intended to moisturize and lubricate, enhance the ease and comfort of intimate sexual activity and supplement the body's natural lubrication. This product is not compatible with natural rubber latex condoms but is compatible with polyisoprene and polyurethane condoms. Page 1 of 4 - Section 5. 510(k) Summary

Kimberly-Clark CorporationK Aa6 0 Traditional 510(k) for Kimberly-Clark Poise Personal Lubricant Description of the device: Poise Personal Lubricant is a water soluble, clear, colorless, viscous liquid composed of purified water, hydroxyethyl cellulose (Natrosol 250), propylene glycol, benzoic acid and sodium hydroxide. Poise Personal Lubricant is presented as a non-sterile product. It is neither a contraceptive nor a spermicide and is sold over-the-counter. The product is packaged in a seventy-four ml plastic, cylindrical pump bottle placed inside a display carton. The outside of the display carton contains a tamper evident seal. Poise Personal Lubricant is a non-greasy and fragrance-free formulation which contains only United States Pharmacopeia (USP) or National Formulary (NF) ingredients. Summary of technological characteristics compared to the predicate device: Poise Personal Lubricant has been shown to be substantially equivalent to the predicate device Durex Play More in terms of technological characteristics such as being water-based and non-sterile, color/appearance/odor, ph, viscosity, specific gravity, osmolality and longlasting lubricity measured as coefficient of friction. Poise Personal Lubricant and Durex Play More contain identical formulation components. Stability studies conducted in accordance with ICH Q1ia and.consumer Health Products Association (CHPA) stability guidelines confirm a shelf life of two years for the Poise Personal Lubricant product; the same as that for the predicate device, Durex Play More. Durex Play More is labeled as condom compatible whereas the label for Poise Personal Lubricant says that the product is not compatible with natural rubber latex condoms but is compatible with polyisoprene and polyurethane condoms in condom compatibility testing conducted according to the standards defined by ASTM-D7661-10. No new questions of safety or effectiveness are presented. Based on the comparisons above, nonclinical performance data, biocompatibility review and testing and safety data, we conclude that Poise Personal Lubricant and Durex Play More are substantially equivalent with regards to the general intended use, safety and efficacy. Brief description of preclinical toxicology (biocompatibility) tests: Table 5-1 provides, the biocompatibility tests conducted and the results obtained for Poise Personal Lubricant. Page 2 of 4 - Section 5. 510(k) Summary

Kimberly-Clark Corporation 1 ;L o Traditional 510(k) for Kimberly-Clark Poise Personal Lubricant Table 5-1: Biocompatibility Test Results of Poise Personal Lubricant Endpoint of Study Type Reference Result Toxicological Concern Cytotoxicity In Vitro Cytotoxicity 10993-05 *Non-cytotoxic :s 3.13% Sensitization In Viva - Guinea Pig Maximization 10993-10 Non-sensitizing Assay Vaginal Irritation Rabbit Vaginal Irritation 10993-10 Non-irritating Subacute Toxicity Two week, Rabbit Vaginal Exposure 10993-11 Non-systemically toxic In vitro Bacterial Reverse Mutation 10993-471 Non-genotoxic Genotoxicity In vitro Chromosome Aberration 109D343 Non-genotoxic 1099 33 In Vivo Mouse Micronucleus 1ECO3474 Non-genotoxic MatTek Ocular Irritation In Vitro, 3D Cell Culture (Epiacular) Epiacular WITT Non-irritating *T his formulation contlains Propylene Glycol which in vitro has a moderate cytotoxc poiential. Cytotoxicity is not demonstrated in vivo for propylene glycol or for Poise Personal Lubricant. Oral Toxicity Assessment: The components of the Poise Personal Lubricant formulation have been individually assessed for oral toxicity. These components are Generally Recognized as safe (GRAS) with use levels significantly less than accepted ingestible amounts. Hence, the lubricant product is assessed as Non-Toxic with regards to oral toxicity. Preclinical Microbiological Testing: Microbial Limits Test was conducted on three process validation lots as per USP <61 > and <62>. The product release specification for this test is :5 100 cfu (colony forming unit)/ml and no objectionable organisms to meet lot acceptance criteria. It was found that all three process validation lots met the specification for microbial limits testing by meeting the UISP criteria. Page 3 of 4 - Section 5. 510(k) Summary

Kimberly-Clark Corporation Traditional 510(k) for Kimberly-Clark Poise Personal Lubricant Safety and Effectiveness Assessment: The subject 510O(k) device has undergone extensive biocompatibility, microbiological, stability, and nonclinical laboratory performance testing as described above and in subsequent sections. The results of these studies support the conclusion that the subject 510O(k) device is equivalent and as safe and effective as the predicate device, Durex Play More. Conclusions: Based on the results of biocompatibility testing and nonclinical performance testing, Poise Personal Lubricant is safe for its intended use and is substantially equivalent to the predicate device, Durex Play More, in terms of general intended use, safety and effectiveness. Page 4 of 4 -Section 5. 510(k) Summary

DEPARTMENT OF HEALTH & HUMAN SERVICES Public Health Service 74 Food and Drug Administration 10903 New Hampshire Avenue Document Control Room -W066-G609 Silver Spring, MD 20993-0002 Swarna Mukund, Ph.D. Regulatory Affairs Technical Leader Kimberly-Clark Corporation 1400 Holcomb Bridge Road ROSWELL GA 30076 JUL V 1 A2012 Re: K120650 Trade/Device Naffle: Kimberly-Clark* Poise Personal Lubricant Regulation Number: 21 CFR 884.5300 Regulation Name: Condom Regulatory Class: 11 Product Code: NUC Dated: July 21 2012 Received: July 3, 2012 Dear Dr. Mukund: We have reviewed your Section 5 10(k) premarket notification of intent to market the device referenced above and have detenmined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration. Please note: CDRH does not evaluate information related to contract liability warranties. We remind you, however, that device labeling must be truthful and not misleading. If your device is classified (see above) into either class II (Special Controls) or cldss mi (PMA), it may be subject to additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register. Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, butnot limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part 801); medical device reporting (reporting of medical

Page 2 - device-related adverse events) (21 CFR 803); good manufacturing practice requirements as set forth in the quality systems (QS) regulation (21 CFR Part 820); and if applicable, the electronic product radiation control provisions (Sections 53 1-542 of the Act); 21 CFR 1000-1050. If you desire specific advice for your device on our labeling regulation (21 CFR Part 801), please go to htp/wwfagvaotd/etr~fcscr CR~fcsum 15809.htm for the Center for Devices and Radiological Health's (CDRI-'s) Office of Compliance. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21 CFR Part 807.97). For questions regarding the reporting of adverse events under the MDR regulation (21 CFR Part 803), please go to http://www.fda.gov/medicaldevices/safety/reportaproblem/'defaulthtm for the CDRI-Ls Office of Surveillance and Biometrics/Division of Postmarket Surveillance. You may obtain other general information on your responsibilities under the Act from the Division of Small Manufacturers, International and Consumer Assistance at its toll-free number (800) 638-2041 or (301) 796-7100 or at its Internet address htp/ww.d~o/eia~vcs~eorefro/nut dfuthm Sincerely urs, Benj R. Fisher, Ph.D. Dir c r Division of Reproductive, Gastro-Renal, and Urological Devices Office of Device Evaluation Center for Devices and Radiological Health Enclosure

Kimberly-Clark Corporation INDICATIONS FOR USE Applicant: Kimberly-Clark Corporation 510(k) Number: K(120650 Device Name: Indications for use: Kimberly-Clark* Poiseo Personal Lubricant Poise Personal Lubricant is a personal lubricant, for penile and/or vaginal application, intended to moisturize and lubricate, enhance the ease and comfort of intimate sexual activity and supplement the body's natural lubrication. This product is not compatible with natural rubber latex condoms but is compatible with polyisoprene and polyurethane condoms. Prescription Use OR Over-The-Counter X Per 21CFR 801.109 Subpart D Per 21CFR 801.109 Subpart C (PLEASE DO NOT WRITE BELOW THIS LINE - CONTINUE ON ANOTHER PAGE IF NEEDED) Concurrence of CDRI- Office of Device Evaluation (ODE) (Division 51 n-off Division of Reproductive, Gastro-Refl, and Urologlcal Devices 2 AL9g 510(k) Number