UFES Active protection for switchgear



Similar documents
30 ms High Speed Transfer System (HSTS) Product Description

IEC in ZX Gas-insulated medium voltage switchgear

UniGear ZS1. Medium voltage, arc proof, air insulated switchgear for primary distribution

NATUS NES / NES-H Draw-out Type Medium Voltage Switchgear Systems. Safe energy distribution that meets the highest industrial requirements

MNS is Switchgear System Technical Overview

Safe and secure distribution of medium voltage with AX1

Medium Voltage Products. ZN1 12 kv arc-proof air-insulated switchgear for primary distribution

Siemens AG Power Transmission and Distribution Medium Voltage Division Mozartstr. 31c Erlangen Germany.

METAL-CLAD AND METAL-ENCLOSED SWITCHGEAR 3.6KV~40.5KV. tgood.com. Energy. Fast.

ALTERNATIVE METHODS FOR INTERNAL ARC TESTS ON 12 KV AND 24 KV METAL-ENCLOSED SWITCHGEARS WITH COMPACT RMU

Medium voltage products UniSec for Smart Grid Air-insulated medium-voltage secondary distribution switchgear

The Intelligent AX1 Switchgear for Medium Voltage

Service Power Technologies. Retrofitting A future-oriented concept in lifecycle management

INTERNATIONAL POWER DISTRIBUTION CONGRESS CIDEL ARGENTINA 2002

Safe and reliable distribution network ABB portfolio for medium-voltage indoor applications

Three-phase monitoring relay CM-PFE

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

SF 6 Gas Insulated Switchgear Type SDF for 170 kv

Arc Terminator Active Arc-Resistant Switchgear

MEDIUM VOLTAGE CE-BF SWITCHBOARDS. UP TO 40.5 kv. CE - BF - C - en - REV

Nothing s BetterThan the Original MODAN Power Distribution Systems

Session Eleven: Development of Standards for MV Switchgear Rated for Arc Protection

DS1 Diode-based transient-free capacitor switch

Catalog. Arc Guard System TM TVOC-2

Our brand POWER DYNAMIC PASSION COMMITMENT CREATIVITY. A strong brand for strong products: 8PU Premium. MV Energy

VD4. Vacuum circuit-breaker

Medium voltage arc flash eliminator units VAM 3ED,

Voltage Rated operating voltage [kv] Rated power frequency withstand voltage [kv] Rated lightning impulse withstand voltage [kv]

Power transformers. Generator step-up and system intertie power transformers Securing high-quality AC transmission

Medium voltage indoor circuit breakers ANSI/IEC solutions

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)

Uncompromising safety and comfort The next generation of miniature circuit breakers MCB S 200/S 200 M

High-Voltage Compact Switchgear 3AP1 DTC for 145 kv and 245 kv

Electronic overload relay EF19 and EF45

Electronic overload relay EF65, EF96 and EF146

Product overview brochure. ABB Medium Voltage Products Our one-stop approach for every medium voltage application

Data Center Uninterrupted efficiency, guaranteed reliability and continuous modularity. ABB solutions always work.

e 2 ALPHA Medium Voltage Switchgear Data Sheet K EN

ELEKTROTEHNI KO PODJETJE Leskoπkova cesta 12, 1000 Ljubljana, SLOVENIA

Electronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet

Masterclad Medium Voltage Passive Arc-Resistant Switchgear

ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application.

21 st Century Facilities

Part 1 System Modeling & Studies for Existing Systems

Low Voltage Switchboards The Best Technical Solution for Your Ship

Arc Protection Relay REA 101. Operator s Manual

Arc Protection Relay REA 10_. Product Guide

The complete range of consumer switchboards and switchgear

8. Switchgear and switchgear installations for high voltage up to and including 52 kv (medium voltage)

Siemens Fusesaver. Highest availability and cost savings for your MV distribution network.

Dead Tank Circuit Breaker 72PM40-C Proven reliability through common platforms

Eaton Safety & Reliability Solutions in the Oil & Gas Industry Electrical

Session Four: Internal Arc Safety in New and Existing Switchgear

NF71E-.. / NFZ71E-.. Contactor Relays AC / DC Operated - with Screw Terminals

3.1.1 Full Type Tests & Routine Tests according to Clause 8 2 & Instructions For Installation, Operation & Maintenance

Type-Tested Power Distribution Board 8PT with Rear Busbars. sivacon

How To Make A Power Supply From A Power Generator

High-Voltage Circuit-Breakers 3AP1/ kv up to 550 kv. Power Transmission and Distribution

Emirates Aluminium starts up World s first fully integrated power distribution system from ABB

Choosing for tranquility

7.2KV SL400 Withdrawable Vacuum Contactor-Fuse Combination Units

ESP 120 M1, ESP 208 M1, ESP 240 M1, ESP 415 M1, ESP 277 M1, ESP 480 M1 and M1R variants. Installation instructions ESP M1/M1R mains protectors

MEDIUM VOLTAGE SWITCHGEAR. DI-2, a modular concept combining all mediumvoltage

Analog signal converters CC-E I/I Current / current isolators

Medium voltage products. UniGear 500R 17.5 kv, arc-proof, air insulated switchgear for green applications

Electrical Shore Connections / Cold Ironing

Engineering Specification

Product brochure Multi Functional Switchgear PASS M kv Flexible and compact switchgear solutions for windfarms

Dry-type transformers. Dry-type transformers from ABB The ideal solution for the oil and gas industry

IEC >>> IEC GUIDE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

Advantages of Fixed Circuit Breaker Switchgear

For a phase-to-phase voltage between 100 V and 1000 V. The standard ratings are: 400 V V V (at 50 Hz)

Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages

Houston Service Center Medium Voltage Service and Aftermarket Solutions

Protection from Short-circuit

2004 TRANSMISSION SYSTEMS SEMINAR MEDIUM VOLTAGE, METAL-CLAD ARC RESISTANT SWITCHGEAR: ENHANCING WORKPLACE SAFETY

Relion. Power system protection and automation reference Extending substation life cycle with IEC 61850

Tmax MCCBs. Molded case circuit breakers. Tmax

KOLMA and IHDA Indoor type Cable Current Transformers Catalogue ABB Power Distribution ABB Transmit 1 KKOLMA 1 GB

AutoLink Three-Phase Sectionalizer Specifications. Scope. General. Applicable Standards. Operating principle

Life cycle services for protection and control relays Full support from start to finish

What will MV switchgear look like in the future? by Jean-Marc Biasse

AF / AF09Z stack 3-pole Contactors AC / DC Operated - with Screw Terminals

PPS-PPQ-BT-PIAS RESIN INSULATORS FOR OIL INSULATED ELECTRICAL MACHINES

TRACTION NETWORK MONITORING AND PROTECTION SYSTEM SMTN-3 CITY ELECTRIC TRANSPORT RAILWAYS METRO INDUSTRY

LV MCC LOW VOLTAGE SWITCHGEAR MOTOR CONTROL CENTRE PRODUCT GUIDE

Reyrolle Protection Devices. 7PG17 - XR Intertripping, Interposing, Supervision and Special Purpose Relays. Answers for energy

New Arc Resistant, Compact Metal Clad Switchgear: Meeting ANSI / UL Design Challenges By Ashok Kulkarni and Predrag Milovac

ZS4-SF1-T Screw Clamp Terminal Blocks For 5 x 20 and 5 x 25 fuses - with test socket

Unified requirements for systems with voltages above 1 kv up to 15 kv

Transformer Bushings for GIS

High Voltage Circuit Breakers 3AP Type 72.5 kv to 800 kv Answers for energy.

Power transformers. Special transformers Railway

ZS6-S Screw Clamp Terminal Blocks Disconnect with blade

TWENTIES WORKSHOP, EWEA 2012 Unveiling the future energy system: full scale demonstrations to reach 2020 targets. 17th April 2012

How To Choose A Transformer

Low Voltage Products. Switches Automatic Transfer Switches

New standardized approach to arc flash protection

Uncompromising safety and comfort Miniature Circuit Breaker SU 200 M for branch circuit protection per UL and CSA

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

Transcription:

Active protection for switchgear ABB AG Oberhausener Strasse 4047 Ratingen, Germany Phone: +49 0-0 Fax: +49 0-7 77 Note: We reserve the right to make technical changes or modify the contents of this document without prior notice. With regard to purchase orders, the agreed particulars shall prevail. ABB AG does not accept any responsibility whatsoever for potential errors or possible lack of information in this document. www.abb.com/mediumvoltage We reserve all rights in this document and in the subject matter and illustrations contained therein. Any reproduction, disclosure to third parties or utilization of its contents in whole or in parts is forbidden without prior written consent of ABB AG 4 electronics type QRU00 primary switching element type U REA system 4 electronics type QRU electronics type QRU00 - - Standard electronic tripping unit for the combination with - - Optolink inputs for connection of the REA0 relay High-speed inputs (HSI) Self monitoring Optolink supervision Testing mode for functional check DIP switch configuration Ideal for extension of existing ABB arc protection systems Alternative: Fault detection by non-abb system (Compatibility verification required!) primary switching element type U Ultra-fast operating mechanism with micro gas generator - - Vacuum interrupter - - Compact design - - Versatile in installation - - Long service life DEABB 459 5 gb (04.5-500-AMC) Contact Copyright 05 ABB All rights reserved Optical detection via line or lens sensors Overcurrent detection Selective protection Circuit-breaker failure protection electronics type QRU Alternative electronic detection and tripping unit - - current inputs 9 optical inputs for light detection by lens sensors - - Complete solution for simple protection zones For large protection zones expandable up to 59 lens sensors with ABB arc guard type TVOC- Self monitoring Testing mode for functional check - - DIP switch configuration Fast fault localization certified by: DS 459 6S_GB_04_05.indd 0.0.5 :55

S Speed, Safety, Savings CB T CT PSE HSO PSE Trip CB HSO REA0 Optolink (Trip) QRU00 CB CB CB protection zone Light sensor application (example) Arc extinction within 4 ms (after detection) The active arc fault protection device for switchgear The occurance of an arc fault, the most serious fault within a switchgear system, is mostly associated with extremely high thermal and mechanical stresses in the area concerned. An active arc fault protection system based on the know-how gained from decades of experience with the ABB vacuum interrupter and I S -limiter technology now effectively helps to avoid these negative effects if a fault should occur. The of type is a combination of devices consisting of an electronic device and the corresponding primary switching elements which initiate a -phase short-circuit to earth in the event of a fault. The extremely short switching time of the primary switching element, less than.5 ms, in conjunction with the rapid and reliable detection of the fault, ensures that an arc fault is extinguished almost immediately after it arises. With a total extinguishing time of less than 4 ms after detection, an active protection concept with the enables switchgear installations to achieve a highest possible level of protection for persons and equipment. Unbeatable advantages: Highly increased system and process availability to preserve the greatest possible competitiveness Highly increased operator safety for switchgear especially during or after maintenance work Drastically reduced repair costs by minimizing the effects of faults on the system Minimization of pressure relief measures by application of active protection concepts Avoidance of the severe effects of an arc fault, such as: Extreme pressure Temperature rise up to 0,000 C Burning / vaporization of metal and insulating material Release of particles and hot gases Intensive light / high acoustic stress

Epoxy resin insulation Fixed contact Ceramic insulator Moving contact pin Rupture joint Piston Cylinder Moving contact system Micro gas generator The eliminates the arc fault well before the first peak of the fault current. Example pressure curves, with and without, in a compartment of an air-insulated medium voltage switchgear system with an internal arc fault current of 0 ka (peak) / 50 ka (rms). Primary switching element for one phase. primary switching element type U Electrical maximum characterstics for each voltage category (Different types available) Rated voltage (rms) * kv.4 7.5 7 6 Rated power frequency withstand voltage (rms) kv 5 4 60 70 Rated lightning impulse withstand voltage (peak) kv 95 50 70 Rated frequency Hz 50 / 60 50 / 60 50 / 60 50 / 60 Rated short-time withstand current (rms) ka 00 50 (6) 40 40 Rated peak withstand current ka 0 0 (65) 04 04 Rated duration of short-circuit s 0.5 () Rated short-circuit making current ka 0 0 (65) 04 04 Mechanical properties Dimension (diameter x height) mm ~ 7 x 0 Closing time ms <.5 Contact bounce time ms 0 Service life expectation Number of closing operations Mechanical years up to 0 Micro gas generator years up to 5 * 40.5 kv on request

Applications ABB Service Box, top mounted ABB withdrawable solution Selection of retrofit solutions Particularly for older, non-iac qualified switchgear systems, the allows the highest degree of protection for equipment and operator safety to be achieved. A variety of solutions are available for retrofitting of existing switchgear systems. ABB Service Box (up to 4 kv) Universally usable ABB Service Box for retrofitting of air-insulated switchgear Non-proprietary application Maximum installation flexibility to suit the space available ABB withdrawable solutions The primary switching elements, installed in ABB withdrawable assembly or truck design, provides a simple opportunity to upgrade existing switchgear systems with active arc fault protection The contact with the busbars is established via the isolating contacts of the withdrawable assembly The optimum Plug & Play solution when vacant panels are available Similar solutions are also available for other switchgear types with trucks * New ABB switchgear Also for new ABB switchgear, the integration of is a useful supplement in order to protect this investment against the impacts of an internal arc, and in addition, to increase the operator safety to a maximum. For switchgear of type UniGear ZS for example, the following technical solutions are available: installation in a top box with direct connection to the busbar installation in the cable connection compartment Separate panel with draw-out unit components The can also be provided as a loose OEM component. There are different types of kits available. * on request

Active protection for switchgear ABB AG Oberhausener Strasse 4047 Ratingen, Germany Phone: +49 0-0 Fax: +49 0-7 77 Note: We reserve the right to make technical changes or modify the contents of this document without prior notice. With regard to purchase orders, the agreed particulars shall prevail. ABB AG does not accept any responsibility whatsoever for potential errors or possible lack of information in this document. www.abb.com/mediumvoltage We reserve all rights in this document and in the subject matter and illustrations contained therein. Any reproduction, disclosure to third parties or utilization of its contents in whole or in parts is forbidden without prior written consent of ABB AG 4 electronics type QRU00 primary switching element type U REA system 4 electronics type QRU electronics type QRU00 - - Standard electronic tripping unit for the combination with - - Optolink inputs for connection of the REA0 relay High-speed inputs (HSI) Self monitoring Optolink supervision Testing mode for functional check DIP switch configuration Ideal for extension of existing ABB arc protection systems Alternative: Fault detection by non-abb system (Compatibility verification required!) primary switching element type U Ultra-fast operating mechanism with micro gas generator - - Vacuum interrupter - - Compact design - - Versatile in installation - - Long service life DEABB 459 5 gb (04.5-500-AMC) Contact Copyright 05 ABB All rights reserved Optical detection via line or lens sensors Overcurrent detection Selective protection Circuit-breaker failure protection electronics type QRU Alternative electronic detection and tripping unit - - current inputs 9 optical inputs for light detection by lens sensors - - Complete solution for simple protection zones For large protection zones expandable up to 59 lens sensors with ABB arc guard type TVOC- Self monitoring Testing mode for functional check - - DIP switch configuration Fast fault localization certified by: DS 459 6S_GB_04_05.indd 0.0.5 :55

Active protection for switchgear ABB AG Oberhausener Strasse 4047 Ratingen, Germany Phone: +49 0-0 Fax: +49 0-7 77 Note: We reserve the right to make technical changes or modify the contents of this document without prior notice. With regard to purchase orders, the agreed particulars shall prevail. ABB AG does not accept any responsibility whatsoever for potential errors or possible lack of information in this document. www.abb.com/mediumvoltage We reserve all rights in this document and in the subject matter and illustrations contained therein. Any reproduction, disclosure to third parties or utilization of its contents in whole or in parts is forbidden without prior written consent of ABB AG 4 electronics type QRU00 primary switching element type U REA system 4 electronics type QRU electronics type QRU00 - - Standard electronic tripping unit for the combination with - - Optolink inputs for connection of the REA0 relay High-speed inputs (HSI) Self monitoring Optolink supervision Testing mode for functional check DIP switch configuration Ideal for extension of existing ABB arc protection systems Alternative: Fault detection by non-abb system (Compatibility verification required!) primary switching element type U Ultra-fast operating mechanism with micro gas generator - - Vacuum interrupter - - Compact design - - Versatile in installation - - Long service life DEABB 459 5 gb (04.5-500-AMC) Contact Copyright 05 ABB All rights reserved Optical detection via line or lens sensors Overcurrent detection Selective protection Circuit-breaker failure protection electronics type QRU Alternative electronic detection and tripping unit - - current inputs 9 optical inputs for light detection by lens sensors - - Complete solution for simple protection zones For large protection zones expandable up to 59 lens sensors with ABB arc guard type TVOC- Self monitoring Testing mode for functional check - - DIP switch configuration Fast fault localization certified by: DS 459 6S_GB_04_05.indd 0.0.5 :55