Battery Life in Water Communication Modules



Similar documents
RF Safety Compliance and Duty Cycle for OpenWay CENTRON 4G-LTE Meters December 2015

Radio Frequency Strategy in an AMI Deployment. Larry Eggleston Director, Product Marketing. Michael Schleich Director, Research and Development

Benefits Derived From Automating Meter Reading: Developing Your Business Case

Jefferson Energy Cooperative s Prepaid Program: Using Cellular Solutions for Spot Deployment

Automated Meter Reading Frequently Asked Questions. What is AMR?

Product Datasheet P MHz RF Powerharvester Receiver

IEEE b/g/n WiFi Module. Product Specifications

WIRELESS INSTRUMENTATION TECHNOLOGY

Itron Cloud Services Offering

Itron White Paper. Itron Enterprise Edition. Meter Data Management. Connects AMI to the Enterprise: Bridging the Gap Between AMI and CIS

9,'(2 #6(3$5$725 8VHU V#0DQXDO 96043;

Tire pressure monitoring

2.0 System Description

Z-Wave Gas Reader. Product Manual NQ-9121-EU. From your Z-wave network directly to the cloud! DESCRIPTION

2014 Forecasting Benchmark Survey. Itron, Inc High Bluff Drive, Suite 210 San Diego, CA

smart stewardship smart pipeline patented technology

This is the first in a series of whitepapers that explain distinctive design, function and applications of MOSAIC.

CPUC California Solar Initiative 2010 Impact Evaluation

evolution Fixed Network Advanced Metering Infrastructure

9,'(2 #6(3$5$725 8VHU V#0DQXDO

Developer s Guide to Submetering Submetering Specifications for Multi-Housing Construction

APN1001: Circuit Models for Plastic Packaged Microwave Diodes

WIRELESS MAGNETIC CONTACT

Radio sensor powered by a mini solar cell the EnOcean STM 110 now functions with even less light

Solar Powered Wireless Sensors & Instrumentation: Energy Harvesting Technology Reduces Operating Cost at Remote Sites

Optimizing Energy Operations with Machine-to-Machine Communications

Bluetooth SMART Advertise-Only Beacon Reference Design

AN588 ENERGY HARVESTING REFERENCE DESIGN USER S GUIDE. 1. Kit Contents. 2. Introduction. Figure 1. Energy Harvesting Sensor Node

Itron and Cisco Grid Intelligence

Energy Harvesting Powered Wireless Sensor Node and Asset Tracking Solutions in Random Vibration Environments

Silicon Schottky Barrier Diode Bondable Chips and Beam Leads

DT3: RF On/Off Remote Control Technology. Rodney Singleton Joe Larsen Luis Garcia Rafael Ocampo Mike Moulton Eric Hatch

AMI and DA Convergence: Enabling Energy Savings through Voltage Conservation

KACO-monitoring. onlinecomponents.com. Integrated monitoring available. Monitor up to 32 inverters per prolog. Reliable and accurate data

SKY LF: GHz Two-Way, 0 Degrees Power Divider

AN437. Si4432 RF PERFORMANCE AND FCC COMPLIANCE TEST RESULTS. 1. Introduction. 2. Relevant Measurements to comply with FCC

Application Note SigC667x-64 Cards Power and Thermal Evaluation

Empowering intelligent utility networks with visibility and control

Maximizing Range and Battery Life in Low-Cost Wireless Networks

WHITE PAPER. Improving the Effi ciency of the Proactive Contact Center

APPLICATION NOTE. Atmel AVR134: Real Time Clock (RTC) Using the Asynchronous Timer. Atmel AVR 8-bit Microcontroller. Introduction.

Solar Powered CUSTOMER. PosiGen Solar Solutions CHALLENGE

Oracle Utilities Customer Care and Billing

SKY LF: 20 MHz-3.0 GHz High Power SP4T Switch With Decoder

ÇANKAYA ÜNİVERSİTESİ ECE 491 SENIOR PROJECT I ERDİNÇ YILMAZ

Integrated Metering Systems, Inc.

Design Considerations for RF Energy Harvesting Devices

FM TRANSMITTER & RECEIVER HYBRID MODULES. FM-RTFQ SERIES FM-RRFQ SERIES. Transmitter. Receiver. Applications

I-210+ and I-210+c Meters

Figure 1.Block diagram of inventory management system using Proximity sensors.

ASKING FOR ASSISTANCE

IBM asset management solutions White paper. Using IBM Maximo Asset Management to manage all assets for hospitals and healthcare organizations.

Active Smart Grid Analytics Maximizing Your Smart Grid Investment

Leak Detection Theory: Optimizing Performance with MLOG

RFRB0413 RF Ranging Base (Preliminary)

D. Infrared scanning reports with pictures printed in a final report with any deficiencies and actions taken to rectify.

How To Use A Watt Saver On A Microcontroller (Watt Saver) On A Cell Phone Or Mp3 Player

PACKAGE OUTLINE DALLAS DS2434 DS2434 GND. PR 35 PACKAGE See Mech. Drawings Section

Key Features of Meter Data Management Systems

ENTERPRISE MANAGEMENT AND SUPPORT IN THE INDUSTRIAL MACHINERY AND COMPONENTS INDUSTRY

An Oracle White Paper May Smart Grid Basics. Turning Information into Power

SuperGuard VT-05 Vehicle Tracking Device

ZigBee Technology Overview

The Energy Harvesting Tipping Point for Wireless Sensor Applications

Video Splitter VS-104 / VS-108 User's Manual

Endpoint-Link Pro Field Service Representative s Guide

Extender for HDMI 1.3 over CAT6. GTV-HDMI1.3-CAT6 User Manual.

December 19, Mary Alice Page-Allen Town of Oak Creek 129 Nancy Crawford Blvd. PO Box 128 Oak Creek, CO 80467

UPS Applications and VRLA Battery Sizing

Skyus 3G. Quick Start Guide Verizon

ELORA 240 BATTERY. Owner s Manual Revision A

Efficient Asset Tracking: From Manual to Automated

White Paper Reduce Total System Cost in Portable Applications Using Zero-Power CPLDs

The True Cost of Batteries why energy harvesting is the best power solution for wireless sensors

METERS Data Collection CONTROL. Dialog3G. AMR/AMI Solutions

Project Documentation EKTSDG Target Simulator Doppler Generator

The ROI for Automatic Container Tracking Using RFID. A Case Study Analysis based on Re-usable Intermediate Bulk Containers

REMOTE KEYLESS ENTRY SYSTEM RECEIVER DESIGN

Nardalert S3 Non-Ionizing Radiation Monitor

Application of Wireless Sensor Network and GSM Technology: A Remote Home Security System

Temperature & Humidity SMS Alert Controller

Version 1.2. Enhancements. Microsoft Business Solutions. Retail Management System

SMS : Surface Mount, 0201 Zero Bias Silicon Schottky Detector Diode

WELCOME. Landis+Gyr Technical Training Catalog

Application Note AN-00126

EDK 350 (868 MHz) EDK 350U (902 MHz) EnOcean Developer Kit

Charger Output AC Ripple Voltage and the affect on VRLA batteries

M.S Ramaiah School of Advanced Studies - Bangalore. On completion of this session, the delegate will understand and be able to appriciate:

TECHNICAL NOTE 7-1. ARCNET Cable Length vs. Number of Nodes for the HYC9088 in Coaxial Bus Topology By: Daniel Kilcourse May 1991.

OpenWay Radio Frequency FAQ

Whitepaper. NVIDIA Miracast Wireless Display Architecture

Voltage Drop. Voltage Drop 1

The Complete Solution for the Utility Mobile Workforce. Today and for the smart grid future

Smart Wireless Devices. LAN-WMBUS-G Wireless MBUS, high performance Temperature, Humidity and Pulse counting device.

MS900AC-B-LS User Information

Software Real Time Clock Implementation on MC9S08LG32

Transcription:

Battery Life in Water Communication Modules Satish Bhakta Ph.D. Advisor, Hardware Solutions WHITE PAPER

Battery Life in Water Communication Modules TABLE OF CONTENTS Introduction... 3 Battery Technology... 3 Determining Battery Life... 3 Lab Testing Program... 3 Field Testing Program... 3 Wake-Up vs. Bubble-Up Mode... 4 Wake-Up Mode (50W Series ERT modules only)... 4 Bubble-Up Mode (50W, 60W, 100W, 100W+, and 200W Series)... 4 Calculating Battery Life... 4 50W Series... 4 200W Series... 4 60W Series... 5 60W Encoder... 5 60WP Pulser... 5 100W/100W+ Series... 5 Battery Life Expectations in Bubble-Up Mode... 5 Field Testing Program for Water Endpoints... 6 Battery Quality Program... 6 Summary... 6

INTRODUCTION For water providers utilizing automated meter reading (AMR) technology or advanced metering infrastructure (AMI), battery longevity and the frequency of battery replacement in radio frequency (RF)-based endpoints are critical factors in maximizing the benefi ts of these systems. The cost of replacing batteries especially the labor portion can have a huge impact on the total cost of the AMR or AMI system. When comparing technologies, utilities need to consider the total lifecycle cost, including battery replacement, to gain a full understanding of the true AMR or AMI system costs. The frequency of the transmission required by the selected meter data collection system is critical to battery life, whether it is a mobile AMR, fi xed network AMI or hybrid (combination AMR/AMI) system. In designing AMR/AMI endpoint functionality, the laws of physics state: The higher the output power and the greater the frequency of transmission, the shorter the battery life. Designing for extended battery life increases the long-term performance of AMR/AMI systems and minimizes costs related to system maintenance and battery replacement. This paper discusses battery longevity for the 50W, 60W, 100W/100W+, and 200W series water communications modules. Itron s battery predictions are based on understanding the physics of failure, modeling, and lab and fi eld tests on functional units. BATTERY TECHNOLOGY Itron modules use two A cell Li-SOCl2 batteries in the 50W, 60W and 100W/100W+ ERT modules. The 200W series endpoints use a single D cell Li-SOCl2 battery. The 50W, 60W and 100W/100W+ ERT modules are used in Itron s 900 MHz handheld, mobile, and fi xed network meter data collection solutions. 200W endpoints are used exclusively in the Itron 1.4 GHz water Fixed Network 2.5. DETERMINING BATTERY LIFE Battery life is dependent on battery capacity, the meter module s operating specifi cations, and transmission frequency. Itron determines the average battery life using a combination of lab tests, modeling, and fi eld monitoring. Lab Testing Program Battery failures can occur due to the following conditions:» Capacity exhaustion, relative self-discharge, and voltage drop due to the operating conditions» Integrity of the battery case holding the electrolyte and Li metal To evaluate both physical and battery chemistry characteristics, Itron develops test models and conducts accelerated life tests to determine battery susceptibility to the above failure modes. These experiments include battery discharge under various conditions, impedance measurements, and micro-calorimetry experiments. Itron then uses the lab results to verify the model assumptions and determine pertinent model parameters. Field Testing Program In 1997, Itron began a program to validate battery life design on gas ERT modules at several utilities. In this program, gas ERTs which have been in the fi eld for more than fi ve years are selected from six to eight utilities. Repeated data accumulation and analysis from the same customer base helps to ensure correlation between real world fi eld experience and Itron s battery life predictions. Testing takes into account variables such as product type, battery type, location and climate, and the type of data collection technology used. For more information on battery life in Itron gas ERT modules, see The Proving Ground: Gas ERT Battery Performance (Publication 100753WP-01). Leveraging the data and methodology from the gas ERT module battery testing, Itron conducts water communication module fi eld monitoring to improve the accuracy of battery life prediction models for water modules. Through this program, Itron engineers new communication modules and matches them with the best type of research-proven batteries.

WAKE-UP VS. BUBBLE-UP MODE AMR/AMI endpoints operate in two basic modes: Wake-Up and Bubble-Up. Battery life varies signifi cantly depending on the operating mode required by the utility. Wake-Up Mode (50W-Series ERT modules only) In Wake-Up mode, the ERT module transmits the meter reading only when it receives a wake up signal from a reading device that is within RF range. Typically, this is a handheld or mobile reading device. This approach conserves battery power, since the ERT module only transmits when the meter reading device is within range. Wake-Up mode allows utilities to take advantage of a longer battery life, however, sending a wake up signal requires a Federal Communications Commission license. Bubble-Up Mode (50W, 60W, 100W, 100W+, and 200W Series) In Bubble-Up mode, the meter reading is transmitted continuously within the module s frequency band. The advantage to this approach is that a FCC license is not required. This approach is optimally used with fi xed network AMI systems for daily and hourly readings; however, Bubble-Up mode can also be used with other AMR meter data collection solutions. To support mobile AMR systems where the vehicle drives at normal speeds the meterreading is transmitted every few seconds. These more frequent transmissions signifi cantly shorten battery life. When users collect large amounts of interval data from the 100W or 100W+ ERT modules, collection results are more reliably acquired if users drive at slightly slower speeds. When the 50W and 50W-1 ERT modules were fi rst introduced in 2001, the modules used two A-cell ER17/50 2750 mah capacity Lithium batteries. In March 2002, Itron started using two highercapacity 3300 mah batteries. By January 2003, all 50W series ERT modules were manufactured with 3300 mah capacity batteries. When operating in Wake-Up mode, the battery life exceeds the 20-year design life of the ERT module, for both 2750 and 3300 mah capacity batteries, making battery replacement programs unnecessary. For 50W series ERT modules operating in Bubble-Up mode with 2750 mah capacity batteries, the more frequent transmission of the ERT module resulted in an average estimated battery life of 10 years. With 3300 mah capacity batteries (which are now used exclusively), the battery life increases to a minimum of 10 years.» Average battery capacity (Wake-Up) = 6.6 Ah» Average battery capacity (Bubble-Up) = 6.6 Ah during Wake-Up = 10 μa. during Bubble-Up = 32 μa. during Wake-Up conditions = 2.89 μa. under Bubble-Up conditions = 10.54 μa. To calculate battery life for the 50W series ERT modules used in Wake-Up mode, where the endpoint is read on a monthly basis: ( 6.6 x 10 6 ) ( 10 + 2.89 ) / 8760 = 58.45 years To calculate battery life for the 50W series used in Bubble-Up mode, where the ERT transmits once every three seconds: ( 6.6 x 10 6 ) ( 32 + 10.54 ) / 8760 = 17.71 years CALCULATING BATTERY LIFE Itron uses the following formula for calculating battery life: Hours = Average battery capacity (in micro amp hours) Average current consumed by circuit + self discharge (micro amps) (To convert hours to years, divide the answer by 8760, the number of hours in a year.) 50W Series With its dual-mode operational capability, the 50W series ERT module encodes accurate consumption and tamper information from the water meter and can be programmed to communicate with 900 MHz Itron meter reading technologies in either Wake Up or Bubble Up modes. 200W Series The 200W series endpoints are designed specifi cally for use with the Itron water Fixed Network solution. The high-powered 1.4 GHz 200W endpoints deliver 1 watt of RF power, enabling utilities to optimize the use of concentrators (CCUs) in the network. Data logging allows for storage and retrieval of 35 days of hourly consumption information. 200W endpoints only operate in Bubble- Up mode.» Average battery capacity = 16.5 Ah during standby and Bubble-Up = 54 μa.» Self-discharge of the D size battery, under these conditions = 38.7 μa. ( 16.5 x 10 6 ) ( 54 + 38.7 ) / 8760 = 20.30 years

60 Series The compact 900 MHz 60W encoder and 60WP pulser ERT modules provide superior performance in harsh pit environments and require no fi eld programming for easy, low-cost installation. Advanced leak, reverse-fl ow and tamper detection help utilities reduce O&M expenses and improve customer satisfaction. The 60 series only operates in bubble-up mode. 60W Encoder» Average battery capacity = 7.3 Ah during standby and bubble up = 30 μa. under these conditions = 9.81 μa. 60WP Pulser» Average battery capacity = 7.3 Ah. during standby and Bubble Up = 38 μa. under these conditions = 12.75 μa. ( 7.3 x 10 6 ) (30 + 9.81 ) ( 7.3 x 10 6 ) (38 + 12.75 ) / 8760 = 20.93 years / 8760 = 16.42 years 100W/100W+ Series The advanced 100W and 100W+ ERT modules allow water utilities to capture large amounts of information for use in many ways across the utility from customer service to engineering; distribution planning to conservation; and fi eld service to executive management. The 100W/100W+ provides the advanced functionality desired by utilities and Itron s proven product reliability. the 100 series delivers a low total cost of ownership. A single ERT module gives water utilities the fl exibility to collect meter data in mobile, fi xed network, and hybrid environments. 100W and 100W+ ERT modules are compatible with water meters from all leading manufacturers. Battery life calculation for a typical 100W or 100W+ encoder model operating in a Mobile/HH environment and transmitting a SCM/ SCM+ message is shown below. Pulser models and various fi xed network operation will have slightly different battery life predictions.» Average battery capacity = 7.3 Ah. during standby and Bubble Up = 26.30 μa. under these conditions = 8.48 μa. ( 7.3 x 10 6 ) / 8760 = 23.96 years (26.3 + 8.48 ) Battery Life Expectations in Bubble-Up Mode Itron learned from the design and subsequent studies of the Itron 40G series gas ERT modules. We applied what we learned to develop batteries that provide even better performance for our newest meter modules which operate only in Bubble-Up mode. Bubble-Up only modules include the 60W, 200W, 100W and 100W+. 50W Series 60W Series 60WP Series 100W/100W+ Series* 200W Series Average Battery Life 17.71 years 20.93 years 16.42 years 23.96 years 20.3 years Collection Systems Handheld, Mobile, Handheld, Mobile Handheld, Mobile Encoder, Water Fixed Network 2.5 Fixed Network 2.0 Fixed, Network 2.0 Fixed, Network 2.0 Handheld/Mobile, SCM/SCM+ ERT Module Design Life 20 years 20 years 20 years 20 years 20 years *The battery life is different for various pulser type endpoints and network applications with examples shown in the following table. Values listed are based on a 25º(C) endpoint operating temperature. Type of ERT Module (100W+ Series) ERT Module Reading Configuration Average Current Calculated Battery Life Pulser with Leak Sensor+ Secure Fixed Network mode 33.9 ua 18.46 years (16 bit intervals) with SCM+ Encoder with Leak Sensor+ Secure Fixed Network Mode 28.0 ua 22.47 years (16 bit intervals) with SCM+

Field Testing program for Water Endpoints Itron recently implemented the 60WP Field Program. The battery life data from the fi eld fully supports the model prediction, which in turn, gives credence to the Itron model. Utility/Product Field Life (in years/ standard deviation) Model Predictions (in years) CoH/60WP (2009) 15.69/1.87 16.42 CoH/60WP (2010) 16.04/0.86 16.42 Aqua/60WP 15.03/0.843 16.42 As shown by the table data and taking component variations into account, the data substantiates the model predictions. BATTERY QUALITY PROGRAM Itron works continuously to achieve the maximum performance at the lowest cost. Batteries from our vendors undergo an exhaustive test program in both standalone and installed states before they are qualifi ed for use in Itron products. Itron implements a battery quality program, testing approximately 30 batteries pulled from our production line (samples from all vendors) bi-monthly. Battery tests include short-term/long-term reliability and performance tests to ensure consistent battery performance. SUMMARY Millions of customers continue to benefi t from patented Itron products. Batteries used in Itron communication modules assure long product life to maximize your investment in Itron systems and minimize your operational costs. Itron is committed to our customers through our proven AMR/AMI technology that optimizes battery life and delivers the longest communication module battery-life in the industry. Join us in creating a more resourceful world. To learn more visit itron.com While Itron strives to make the content of its marketing materials as timely and accurate as possible, Itron makes no claims, promises, or guarantees about the accuracy, completeness, or adequacy of, and expressly disclaims liability for errors and omissions in, such materials. No warranty of any kind, implied, expressed, or statutory, including but not limited to the warranties of non-infringement of third party rights, title, merchantability, and fi tness for a particular purpose, is given with respect to the content of these marketing materials. Copyright 2014 Itron. All rights reserved. 101152WP-02 11/14 CORPORATE HQ 2111 North Molter Road Liberty Lake, WA 99019 USA Phone: 1.800.635.5461 Fax: 1.509.891.3355