ADK Installation and Service Instructions



Similar documents
ADT Installation and Service Instructions AUTOMATIC DRAIN KIT MODEL ADT WARNING SAVE THESE INSTRUCTIONS

Watts Pure Water Systems

Select Radiators Installation Guide

SYSTEM PLUMBING KIT INSTALLATION, OPERATION & SERVICE MANUAL. PENTAIR POOL PRODUCTS CORPORATE OFFICE Sanford, NC (919)

Use & Care Manual. Electric Tankless Water Heaters. With Installation Instructions for the Installer AP15447 (10/10)

OWNER S MANUAL FORCE 10 MARINE COMPANY HAMILTON ROAD RICHMOND, BC CANADA V6V 1C9 TEL: (604) FAX: (604)

Your safety and the safety of others are very important.

Pre-Fab Easy Installation For Models: 006-CT-USK, 008-CT-USK Installation and Operating Instructions for Existing Homes with Standard Piping

SunMaxx Solar Filling Station Operating Instructions

INSTALLATION INSTRUCTIONS & HOME OWNERS MANUAL ECO 18 ECO 24 ECO 27 IMPORTANT SAFETY INFORMATION

I N S T A L L A T I O N I N S T R U C T I O N S F O R T H E H i l k o i l Energy S aving Hot Water Kit

AF Series Generator. Installation Operation Manual thermasol.com/solutions SSA-ACR, SSA-84, SSA-140, SSA-240, SSA-395, SSA-500

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS

SYSTEM PLUMBING KIT INSTALLATION, OPERATION & SERVICE MANUAL. PENTAIR POOL PRODUCTS CORPORATE OFFICE Sanford, NC (919)

Hot, Warm and Cold Mineral Water Cooler [Models Cool18, Cool25, Cool36, Cool50, Cool75, Cool100]

Air Conditioner Water Heater Model ACWH18

Oil and Coolant Circulating Heating System. Model - OCSM

I N S T ALLATION INSTRUCTIONS & HOME OWNERS MANUAL IMPORTANT SAFETY INFORMATION

Whole House Water Treatment System. Installation, Operation and Maintenance Manual. Multi-Pure Model TO15000

Model 1210C Battery Powered Pump Shown. Description

Installation and Troubleshooting Instructions for Electric Tankless Residential Water Heaters.

! WARNING. Before using product, read and understand instructions.

H41 Electrical Stage Aft Air Conditioner Unit Installation

Speedflow Undersink Unvented Water Heater. Models SF10K and SF15K. Instruction Manual

Overview PARTS LIST. B. Lever mounting base C. Flush handle assembly D. Grey/Blue float stop E. Grey float (Full Flush) F. Flush valve washer

Electric Water Heater

OWNER S MANUAL & INSTALLATION GUIDE. Installation Details Owner s Information Warranty. 80L - 400L Electric Storage Water Heaters

INSTANT HOT WATER RECIRCULATING SYSTEM

THE BOILING WATER DISPENSER INSTALLATION & OPERATING INSTRUCTIONS

THE BOILING WATER DISPENSER INSTALLATION & OPERATING INSTRUCTIONS

Estimated Water Savings

Operator: Save these instructions for future use!

INSTALLATION INSTRUCTIONS & HOME OWNERS MANUAL EEMAX ELECTRIC TANKLESS WATER HEATERS IMPORTANT SAFETY INFORMATION

2010 Residential Water Heater Replacement Check List

SF15K SF05KSS, SF10KSS

WATER LEAK DETECTION G

Installation and Operating Instruction Manual

SECTION COMMERCIAL PLUMBING FIXTURES

Mini Tank. Electric Mini Tank Water Heaters WM-1.0 WM-2.5 WM-4.0 WM-6.0. Installation and Operating Instruction Manual

Heating, Ventilation, Air Conditioning and Refrigeration (HVACR)

Electrical Connection. Provide Proper Electrical Supply. Electrical Requirements. Connecting using the supplied cord and plug

36G22, 36G23, 36G24 & 36G52 36J22, 36J23, 36J24 & 36J52 DSI and HSI Single Stage Combination Gas Valve

Installation, Maintenance, & Repair Series 4000B/LF4000B

TECHNICAL ASSISTANCE TOLL FREE TELEPHONE NUMBER TECHNICAL ASSISTANCE FAX:

Sun Bandit Hybrid Water Heater Installation, Operation and Solar Hybrid Energy Systems Patent(s) Pending

MASTER. Installation and Operation Manual. Water Conditioning Corp. MCA Time Clock Series Residential Softeners. February 2011 Version

Miami Heat Pump HP Series Installation Guide

When Should Examination Preparation Begin?

Volvo Penta Quality Line Marine Water Heaters. Owners Manual

How To Build A Backwater Valve

INSTALLATION & OPERATING INSTRUCTIONS

Static Electricity. A Health and Safety Guideline for Your Workplace. What Are Some Sources of Static Electricity? What is Static Electricity?

MBA-MM-1040/10/13/1665 MULTI MEDIA FILTERS

INSTALLATION AND OPERATION INSTRUCTIONS - (LOW FLOW MODELS) (Before installation, compare electrical needed for the model of heater selected)

Minimum Standards for Data/Voice Infrastructure in New Building Construction

TABLE 1. Rugged cast aluminum alloy casing,celcon waterways with nichrome parts White (unless stainless steel housing)

Report for. Dick and Jane Homeowner Lovers Lane, Houston, Texas 77000

SHC 2.5, SHC 4 MINI-TANK ELECTRIC WATER HEATERS INSTALLATION INSTRUCTIONS FOR THE LICENSED PLUMBER SHC 2.5 SHC 4. English. English

CHAPTER 10 BOILERS, WATER HEATERS AND PRESSURE VESSELS

detection kit the water leak water leaks: What you should know A helpful guide for locating indoor and outdoor water leaks Getting Ready

Questions and Answers for Heating and A/C Contractors

INSTALLATION INSTRUCTIONS MK-8704

Installation Manual DIAPHRAGM WELL TANK

STEAM AND CONDENSATE PIPING AND PUMPS DESIGN AND CONSTRUCTION STANDARD PART 1: GENERAL Purpose:

Techtanium Solar Indirect Water Heater Instruction Manual

15CI and 25CI Reversing Motor Pumpset Owner's Manual

PIPES AND TUBES FOR HVAC PIPING AND EQUIPMENT

TRAINING AND EQUIPMENT MANUAL HOSE PRACTICES EFFECTIVE: OCTOBER 2007

Mini Tank water heater Electric undersink Water heaters GL GL 4 - GL 6+

DIGITAL ALARM II FOR HOSPITALS AND LABORATORIES INSTALLATION AND OPERATING INSTRUCTIONS

ELECTRIC WATER HEATER INSTALLATION & OPERATING INSTRUCTION MANUAL

Float and Thermostatic Traps Series H, C and X

INSTALLATION INSTRUCTIONS GEO-BOOSTER TM

INDIRECT WATER HEATER. Installation and Operating Instruction Manual

Owner s Guide and Installation Instructions

CLIENT. Inspection Report. 271 Front St. Alert Bay, B.C. Island Building Inspections V ANCOUVER I SLAND B. C.

ATS Overhead Table Shelf System INSTRUCTION MANUAL

INSTALLATION GUIDE AND OWNER S MANUAL

OVER-HEAD SEWER ASSISTANCE GRANT

Solar Panel Installations

Air Conditioner Water Heater - A Product of HotSpot Energy LLC

with MERCURY FREE 1 HP Relays ! WARNING Before using this product read and understand instructions.

A.Y. McDonald Mfg. Co. Troubleshooting Submersible and Jet Pumps

INSTRUCTION MANUAL A REVISION A. Series E1 and E3 Instant Hot Water Recirculating Systems

PARTS CATALOG RPPCR01111_Front_Backcx.indd 1 RPPCR01111_Front_Backcx.indd 1 11/21/11 1:41 PM 11/21/11 1:41 PM

METER REQUIREMENTS GENERAL REQUIREMENTS SECTION D

Unvented water heater

Instruction Manual. Ultrasonic Cleaning Tank. Advanced Ceramics Technology (M) Sdn. Bhd A Crest Group Inc. Company

Ceiling Mount Air Handler Manual

Water Heaters. Use & Care Manual. Electric Point of Use IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS

3. SEISCO PARTS & SERVICE REMOVAL AND REPAIR GUIDE

Before repairing your toilet, you must determine

PART 8: FIELD WIRING. n WARNING NOTICE. Boiler Manual

Module 7. Plumber: Sink Installation

Beacon Hill Sewer District Standard Specifications

Home Inspection Report

Transcription:

Electrical grounding is required on all Steambath Generats. Do not remove change the Generat's grounding unless specifically directed to do so by these instructions. All electrical supplies to the Generat should be disconnected befe and during the installation of this Option. AUTOMATIC DRAIN OPTION KIT MODEL ADK SAVE THESE INSTRUCTIONS All wiring must be installed by a licensed electrical contract in accdance with local and national codes. All plumbing must be installed by a licensed plumber in accdance with local and national codes. (an air gap check valve may be required) READ ALL INSTRUCTIONS CAREFULLY BEFORE INSTALLATION. SECTION 1: GENERAL INFORMATION The Steam Generat is listed by Underwriters Labaties. The Underwriters Labaties listing will remain valid so long as the Option Kit is installed per these instructions. This ADK Option Kit upgrades a Generat to automatically flush and drain twenty (20) minutes after the last use. It will leave the tank empty after the flush and drain cycle. A second ADK Option is used f ganged generats.

page 2 DIAGRAM 1 DIAGRAM 2 CONDUIT Single Generat Installation DIAGRAM 3 DIAGRAM 4 SHELF, BENCH OR FLOOR MOUNT DIAGRAM 5 DIAGRAM 6 WALL MOUNT - HORIZONTAL

page 3 SECTION 2: INSPECT EXISTING LOCATION 1. Count the total number of Generats at this site. 2. If there are two (2) three (3) Generats this kit must be installed on all Generats. 3. If there is only one Generat proceed to Section 3A. If there are two (2) three (3) Generats skip ahead to Section 3B. SECTION 3A: SINGLE GENERATOR PLUMBING INSTRUCTIONS All plumbing shall be installed by a licensed plumbing contract and confm to local and national codes. (an air gap check valve may be required) MATERIAL (Locally available) - 1/2 inch copper pipe f the tank drain - Fittings f drain as required - Pipe thread compound teflon tape 1. If the Option is being installed in an existing Generat it will be necessary to remove enough drain plumbing to install the motized drain valve. See Diagrams 1, 2 & 3 f guidance. All Generat plumbing must be installed so that removing the valve clears the element service clearance area shown in Diagram 2. 2. Install the 3" nipple to the tank. Attach the motized drain valve to the nipple. The drain valve should be upright and level. Ball valve does not have direction flow. Do not tilt over 45 degrees. See Diagram 1. Run a 1/2" copper drain line from the motized drain valve outlet to a gravity flow drain. Do not run the drain uphill. The drain must be connected in accdance with local and national codes. All plumbing must be installed by a licensed plumber in accdance with local and national codes. (an air gap check valve may be required by local codes) Boiling water may be discharged from the drain. Draining the tank into the Steam Room may present a scald hazard and/ damage materials used to construct the Steam Room. SECTION 3B: MULTIPLE GENERATOR PLUMBING INSTRUCTIONS All plumbing shall be installed by a licensed plumbing contract and confm to local and national codes.(an air gap check valve may be required) MATERIAL (Locally available) - 1/2 inch copper pipe f the tank drain - Fittings f drain as required - Pipe thread compound teflon tape Detailed drain connection infmation is in the Installation Instructions packed with the Generats. The instructions must be used to assure proper drain operation. 2. Install all automatic drain valves provided. All valves should be installed as shown in Diagrams 1 thru 6. All motized drain valve outlets must be within six (6) feet and one (1) 90 bend of the site gravity drain. Use pipe thread compound teflon tape on all threaded fittings. 1. If this is an old installation being upgraded, it can require up to three (3) automatic drain valves, one per generat. If additional drain valves automatic drain valve kits are required, call the Service Department at 1-800-363-0251. SECTION 4: This section intentionally left blank

page 4 DIAGRAM 7 DRAIN WIRING CONNECTION: TB2 DIAGRAM 8 DIAGRAM 9 KNOCKOUTS INTENTIONALLY LEFT BLANK DIAGRAM 10 TB2

page 5 SECTION 5: WIRING SEE DIAGRAMS 7, 9 & 10 1. The safety of this equipment requires power and control wiring be segregated into the areas shown in Diagram 7. 2. Route the drain valve wires through the conduit to a knock out near the steam outlet. See Diagram 9 & 10. Route the wires into the TB2 drain terminal block on the PCA. See Diagram 10. 3. F multiple Generat installations check f other motized drain valves in the system. All drain valves connect to TB2 terminal block on PCA's. All electrical supplies to the Generat should be disconnected befe and during installation of this Option. User Shock Hazard! 220V wires attached to this Option must be routed per these instructions. SECTION 6: OPERATIONAL TEST 1. Assure power and water are on. 2. Turn on the Generat(s) using the owner's control. Allow the tank(s) to fill completely. water will be added to the generat as needed to cool the water and drain the tank. After about 5 minutes, this will stop and the tank will remain empty until the next bath. No water should come out the steam head. User Shock Hazard! If existing wiring is disturbed assure that the final installation confms with generat wiring diagram. Conduit must be used when installing drain valve to connect the valve to ground. 3. Turn off the Generat(s) using the owner's control. The unit is now ready f operation. 4. Twenty minutes (20) after the Generat is turned off, the drain will open and close a few times and SECTION 7: TROUBLESHOOTING GUIDE There are no user serviceable parts in the Generat. All repair should be perfmed by a qualified service person. F additional assistance the facty authized service person nearest you call the Service Department at 1-800-363-0251. The Troubleshooting Guide below is meant as a general aid only. Follow ACTION TO BE TAKEN in der until the problem is resolved. SYMPTOMS PROBABLE CAUSES ACTION TO BE TAKEN All Drain Valves do not close. Drain Valve faulty 1. Identify and replace the PCA. 2. Replace the Motized Drain Valve. All Drain Valves stay closed. Drain Valve faulty 1. Identify and replace the PCA. 2. Replace the Motized Drain Valve. Drain Valves appear to open but water comes out any steam head during flush and drain cycle. Drain Plumbing 1. Crect drain plumbing using this document. Crect ganged multiple Generats using the Installation Instructions. Slave Drain Valve does not operate properly. Cable faulty 1. Check that the Cable between the two generat PCA's (if used) is installed and secure at both ends. 2. Replace in der the slave PCA then master PCA. All other problems Various 1. Call the Service Department at 1-800-363-0251.