USAR Marking System. Structure/Hazards Marking System



Similar documents
NEIGHBORHOOD DISASTER PLAN TEMPLATE

A Parents Guide to Emergency Preparedness

Mt. San Antonio College Campus Emergency Response and Evacuation Plan

Evacuation Procedures

EMERGENCY PREPAREDNESS

Factors to Consider When Developing an Evacuation Plan

Sash Replacement Guide

Maryland Emergency Operations Plan

How To Handle An Emergency

OCPS Emergency Response Quick Reference Guide Orange County Public Schools Security Control Center

EMERGENCY PREPAREDNESS PLAN FOR

East Mississippi Community College. Scooba Campus * Mayhew Campus Department of Public Safety. Campus Emergency Action Plan.

Contingency Plan. Facility Name

A Plan Outline for Neonatal Intensive Care Unit Evacuation Institution. Draft 1

Car Park Management Plan SouthGate, Bath SouthGate Limited Partnership

New York State Unified Court System. Workplace Safety Assessment

FACT SHEET: HAZARDOUS MATERIALS ACCIDENTS

Community Emergency Response Teams (CERT) & Individual and Family Preparedness

Ontario Shores Centre for Mental Health Sciences Emergency Response Code List

SAFETY AND HEALTH PROGRAM

Chippewa County Courthouse Security Emergency Procedures. Dial FIRE POLICE AMBULANCE

NATIONAL URBAN SEARCH AND RESCUE RESPONSE SYSTEM

Implementation Date: May 5, Table of Contents. Section Description Page. 1.0 Description Initial Response 2

Fire is the rapid oxidation of a combustible material, releasing heat, light, smoke, and various toxic gases

Landslides & Mudflows

Todd & Cue Ltd Your Business Continuity Partner

EMERGENCY MESSAGE TEMPLATES

PURPOSE A confined space is any area or vessel, which meets all three of the following:

Document Name: Driving Skills. Purpose: To outline necessary driving skills required to maximize driving safety.

BUILDING OCCUPANCY RESUMPTION PROGRAM

TOOELE COUNTY EMPLOYEES EMERGENCY SAFETY HANDBOOK 2012 REVISION

Stop The stop sign, a red octagon with white lettering, means come to a full stop and be sure the way is clear before proceeding.

Building Security Levels Quick Reference Sheet. Security Level 2 Normal Operations. Business as Usual No known threats

There to help when you need us most.

HISTOLOGY LABORATORY EMERGENCY PROCEDURES

Assessments, advising, or additional preparation. Set Designer - -Math --2 years. Assessments, advising, or additional preparation

DISASTER PREPAREDNESS GUIDELINES FOR HORSE OWNERS

EVACUATION & EMERGENCY PREPAREDNESS PLAN

TITLE: ACTIVE THREAT SITUATION RESPONSE PLAN Page 1 of 6

1. Perimeter fencing or walls should enclose the vicinity around cargo handling and loading areas, as well as storage facilities.

Emergency Response Plan

fulfils all requirements for extended protection of the criteria catalogue The appendix is part of the certificate and consists of 4 pages.

ALIA Disaster Planning for libraries

1ST ANNUAL CERT RODEO ROUND UP

Marin County EMS Agency. Attachment B Position Checklists

The crime scene sketch is an invaluable aid in recording

POINT UNIVERSITY CAMPUS SECURITY Emergency Response Plan

All Emergency Operations Plan Le Parc Condominium Gulf Shore Blvd N. Naples, FL 34103

SURVIVE INSIDE: Employee Safety in Confined Spaces

Revision: 1. To document position roles and responsibilities of members of the Washtenaw County Technical Rescue Team.

LAW ENFORCEMENT ESF 16

Living Arts School of Communication Arts Emergency Preparedness Plan. - Table of Contents -

User s Guide. Security Systems D220

EARTHQUAKE SAFETY IN THE WORK PLACE

CRIME SCENE EVALUATION LAB

How To Evacuate The University Of California Building

Walking/Work Surfaces Fall Protection Program

Emergency Preparedness Tips and Actions for the Workplace

Active and Passive Sash Replacement

NPCollege Crisis Management Plan Page 1 of 11. Table of Contents

UFF Position Statement: Fire and Smoke as a Weapon

INSTALL/REMOVAL INSTRUCTIONS: WINDOW REGULATOR

Employee Health and Safety Induction Training Record

ISLE OF MAN FIRE & RESCUE SERVICE FIRE PRECAUTIONS LOGBOOK. Website

Emergency Preparedness

RESCUE INCIDENT. Search and Rescue Operations Following the Northridge Earthquake January 17, 1994 Los Angeles, California

NATIONAL URBAN SEARCH AND RESCUE RESPONSE SYSTEM TASK FORCE EQUIPMENT CACHE LIST

Flood Preparedness Checklist

EMERGENCY MANAGEMENT ORGANIZATION

Template Policy on Healthcare Facility Patient Evacuation and Shelter-in Place

Disaster Preparedness: Are You Ready? District of Columbia Homeland Security and Emergency Management Agency

Emergency Response Manual

How To Certify A Security Area Datacenter For A Trustworthy Site Infrastructure

Section 7: Elevators and Lifts. Main Entry Floor Outside the Elevator

ACTIVE SHOOTER HOW TO RESPOND

Non Invasive Roof Leak Detection Using Infrared Thermography

Hank Christen 02/09/01. The DMAT Safety Officer By Hank Christen, Fl-1 DMAT

Mississippi Emergency Support Function #1 Transportation Response Annex

Excavation Procedure. MIDGA Reviewed: 07/29/14 Effective: 06/20/09 Supersedes: Original Preparer: Owner: Approver: Safety Safety Safety

REACT. Rapid Emergency Action Checklist. The University of Toledo Health Science Campus. Emergency Contact Information for Department or Lab

Fire Safety Requirements for Child Care Centre

WOLVERINE TOWER BUILDING INCIDENT RESPONSE TEAM (BIRT) MEMBER RESPONSIBILITIES

Disaster Recovery Committee. Learning Resource Center Specialist

fufils all requirements for high protection of the criteria catalogue The appendix is part of the certificate and consists of 4 pages.

Things to Think About

REGIONAL OFFICE FOR LATIN AMERICA AND THE CARIBBEAN USAID/OFDA/LAC REGIONAL DISASTER ASSISTANCE PROGRAM (RDAP) TRAINING PORTFOLIO

EARTHQUAKE PREPAREDNESS

The purpose of ESF #9 is to identify search, rescue, and recovery roles and responsibilities within the City of Tucson during a disaster.

Hospital Emergency Operations Plan

Keeping Our Schools Safe Texas Unified School Safety and Security Standards. Dr. Victoria Calder, Director Texas School Safety Center

-1- SPECIFICATIONS CONE SETTER PLATFORM ATTACHMENT INDEX

Cable Support System Guide for Andersen Bow, Bay, and Box Projecting Window Units

EMERGENCY PROCEDURES

Newton Public Schools Security Audits Executive Summary

IN-PLACE PROTECTION (IPP) FOR THE WORKPLACE

Preparing Your Business for a Flood

Transcription:

USAR Marking System Information gathered by search and reconnaissance personnel must be represented in a standardized fashion to ensure uniformity and clarity. The USAR marking system is identified and divided into 3 sections. 1. Structure/Hazards Marking 2. Search Assessment Marking 3. Victim Location Marking System The following activities should be performed prior to beginning search & rescue operations. 1. Identify buildings individually (by address, physical location, etc.) 2. General triage to separate buildings that offer the highest potential for viable rescue opportunities. 3. Hazard assessment and hazard marking of any building prior to search & rescue operations. 4. Search and rescue marking of a building Structure/Hazards Marking System A standardized marking system to identify structures in a specific area and any hazards found within or near the structure. The structure triage, assessment and marking system is intended to be the National Standard system for evaluating, identifying, and marking buildings. It is designed to help identify, select and prioritize the buildings with the largest probability of success with respect to finding and rescuing victims. It is important that information related to building identification, conditions, hazards and victim status are posted in a standardized fashion. The theme of search & rescue must be to save trapped victims while minimizing the risk to the victim and the rescue forces. Structure hazards identified during initial size up activities and throughout the incident should be noted. A 2 foot x 2 foot square box is outlined at any entrance accessible for entry into any structure. Aerosol cans of International Orange spray paint are to be used for this purpose. An arrow should be placed next to the 2 x 2 orange box indicating the direction of the safe entrance, unless the entrance is next to the orange box.

It is essential to mark ALL normal entry points of a building to ensure that personnel approaching the building can identify that it has been evaluated and discern its condition. Put the date, time, hazardous material conditions and team or company identifier outside the box on the right hand side. This information should be made with lumber crayon or lumber chalk. All personnel must be aware of the possibility of, and look for other structure/hazard markings that may be on the inside of the building. Such as interior rooms, hallways, etc. Every time an assessment is performed throughout the mission a new TIME, DATE and ID entry will be indicated below the previous entry or a completely new marking box will be made, if the original information is now incorrect. The depiction of the various markings is as follows: Structure is accessible and safe for search and rescue operations. Damage is minor with little danger of further collapse. Structure is significantly damaged. Some areas are relatively safe, but other areas may need shoring, bracing, or removal of falling and collapse hazards. The structure may be completely pancaked. Structure is not safe for search and rescue operations and may be subject to sudden additional collapse. Remote search operations may proceed at significant risk. If rescue operations are undertaken, safe haven areas and rapid evacuation routes should be created. Arrow located next to a marking box indicates the direction to the safe entrance to the structure, should the marking box need to be made remote from the indicated entrance. HM Indicates that a HAZMAT condition exists in or adjacent to the structure. Personnel may be in jeopardy. Consideration for operations should be made in conjunction with the Hazardous Materials Specialist. Type of hazard may also be noted.

The TIME, DATE, and RESCUE TEAM ID, are noted outside the box at the upper right-hand side. This info is made with carpenter's chalk or lumber crayon. An optional method is to apply duct tape on the exterior of the structure and write the information with a grease pencil or black marker. 7/15/91 1310 hrs. HM - natural gas CA-TF1 The example indicates that a safe point of entry exists above the marking (possibly a window, upper floor, etc.). The single slash means the structure may require some shoring and bracing. The assessment was made on July 15, 1991, at 1:10 PM. There is an apparent indication of natural gas in the structure. The evaluation was made by TF #1 out of the State of California. Search Marking System Search Assessment Marking A standardized marking system employed during and after the search of a structure for potential victims used in conjunction with the Structure and Hazards marking system. Search Markings must be easy to make, easy to read and easy to understand. To be easily seen the search mark must be large and of a contrasting color to the background surface. Orange spray paint seems to be the most easily seen color on most backgrounds and line marking or downward spray cans apply the best paint marks. Lumber chalk or lumber crayons should be used to mark additional information inside the search mark itself because they are easier to write with than spray paint. A large distinct marking will be made outside the main entrance of each building or structure searched. This "Main Entrance" search marking will be completed in two steps. First, a large (approx. 2') single slash shall be made near the main entrance at the start of the search. After the search of the entire structure has been completed a second large slash shall be drawn in the opposite direction forming an "X".

Specific information will be placed in all four quadrants of the Main Entrance "X" summarizing the entire search of the structure. The left quadrant is for the Rescue Team Identifier. The top quadrant is for the date and time the search was completed. The right quadrant is for any significant hazards located in the structure. The bottom quadrant is for the number of "LIVE" or "DEAD" victims still inside the structure. Use a small "x" in the bottom quadrant if no victims are inside the structure. During the search function while inside the structure a large single slash shall be made upon entry of each room or area. After the search of the room or area has been completed a second large slash shall be drawn in the opposite direction forming an "X". The only information placed in any of the "X" quadrants while inside the structure shall be that pertaining to any significant hazards or the number of "LIVE" or "DEAD" victims. Search Assessment Marking A separate and distinct marking system is necessary to conspicuously denote information relating the victim location determinations in the areas searched. The Search Assessment marking system is designed to be used in conjunction with the Structure and Hazards Evaluation marking system. An "X" that is 2' X 2' in size will be made with International Orange color spray paint. This X will be constructed in two operations: 1400 hr CA- TF1 Single slash drawn upon entry to a structure or area indicates search operations are currently in progress. The time and TF identifier are posted as indicated. X Crossing slash drawn upon personnel exit from the structure or area. Distinct markings will be made inside the four quadrants of the X to clearly denote the search status and findings at the time of this assessment. The marks will be made with carpenter chalk, lumber crayon, or duct tape and black magic marker.

X LEFT QUADRANT CA-TF1 Team identifier X7/15/91 1400 hr TOP QUADRANT - Time and date that the personnel left the structure. XRATS RIGHT QUADRANT - Personal hazards. X2 - LIVE 3 - DEAD BOTTOM QUADRANT - Number of live and dead victims still inside the structure. ["0" = no victims] It is important that markings are made specific to each area of entry or separate part of the building. If no victims are found, it is noted with a "0" below. Situation updates are noted as they are available: Previous search markings are crossed out; and New markings are placed below (or next to) their previous markings with the most recent information.

STRUCTURE MARKING SYSTEM Begin by using orange spray paint or lumber crayon to draw a 2-foot box. Then use the box to alert subsequent rescuers to building conditions or earlier findings. Damage is minor with little danger of further collapse. Structure is safe for search and rescue operations. Damage is significant. Shoring, bracing or removal of hazards is necessary. Structure is not safe for search and rescue operations. Remote search operations may proceed at significant risk. Safe havens and evacuation routes should be established. Direction to safely enter building. HM Hazardous material is present. Type of hazard may also be noted. 9/1/95 0800 HM-CHLORINE CATF-2 Write date, time, hazardous materials present and team identification on the right-hand side of the box. For example, this building was searched Sept. 1, 1995, at 8a.m., chlorine was found, and the search was conducted by Los Angeles County CATF-2. SEARCH MARKING SYSTEM Search operations are currently in progress. (ORANGE) Personnel have exited the structure. (ORANGE) 9/1/95 HM- CATF-2 CHLORINE 1-LIVE 1-DEAD Left quadrant Team identifier. Top quadrant Time and date team left the structure. Right quadrant Hazards found. Bottom Quadrant - Number of live and dead victims still inside the structure. Written in Black Marker or lumber crayon/chalk Source: Federal Emergency Management Agency Urban Search and Rescue Task Force System. This page should be laminated and incorporated into your response gear, for future reference.

General Rescuer Safety Procedures 1. Basic rescuer safety equipment (hard hat, ropes, pry bar, first aid kit, etc.) 2. Be aware of safety and health risks around the disaster site 3. Never work alone Use the Buddy system 4. Always have communication radio, voice, or runners 5. Establish evacuation and entrapment signals 6. Assign a Safety Officer to the operation and EACH team 7. Review structure evacuation techniques before entering a structure 8. ALWAYS mark entry point where structure search begins 9. Follow safety precautions for lifting and moving objects Site/Personnel Safety Emergency signaling and evacuation procedures must be understood and immediately recognized. Alerting devices shall be used to sound the appropriate signals as follows: Cease Operation All Quiet 1 long signal (3 seconds) Evacuate the Area Resume Operations 3 short signals (1 second each), followed by pause, repeated until all members are accounted for 1 long and 1 short signal General Rescuer Methodology Rescue the maximum number of victims, with minimum risk to rescuers. Priority with live victims; dead are noted and removed later Initially, rescue victims who are easy to get to, extricate, and evacuate Size up EACH structure before entering Surround structure and check for both victims and safety problems Look for structure/search markings Look through windows, doors, and openings for victims and hazards before entering.