UNDERSTANDING UTILITY COSTS



Similar documents
10 Strategic Steps to Reducing Your Energy Costs AEE Regional Chapter Meeting February 2, 2005

UNDERSTANDING YOUR UTILITY BILL A GUIDE FOR BUSINESSES IN OHIO

Energy Efficiency. Energy Efficient Water Heating: Purchasing a new electric water heater. Hot water use has a significant impact on your bill.

Fuel and Energy Conversion and Equivalence Chart

UNDERSTANDING YOUR UTILITY BILL A GUIDE FOR BUSINESSES IN INDIANA

Energy Audit Data Collection Form

UNDERSTANDING YOUR ELECTRIC BILL

UNDERSTANDING YOUR ELECTRIC BILL

Commercial Energy Savings Guide.

ENERGY AUDITS (OR SURVEYS) & ENERGY MANAGEMENT PROGRAMS SECTION B

Codes and High Performance Hot Water Systems. Gary Klein Affiliated International Management, LLC

Electric Rate Book Revision: 13 ( ) Page No. 1 Effective date: SMALL COMMERCIAL

The main steam enters the building in the basement mechanical room; this is where the condensate line also leaves the building.

Dallas/Fort Worth International Airport District Energy Plant Upgrades Project Making More with Less Sustainable Communities Conference Dallas, TX

Energy Audits. Good energy management begins with an energy audit

Commercial and Industrial Electric Rates

The Only GUY To Call. Why are my utility bills so high? What can I do to lower my energy expenses?

Air-Conditioning Buying Guide

Sea Water Heat Pump Project

Load Management Wiring Guide

Sample Bill. Understanding Large Commercial Electric Bills. White Paper #22. Demand-Based Time of Use Electric Rates Have Some Unique Terms

Energy Audit of a Brewery A Case Study of Vitamalt Nig. Plc, Agbara

HOW TO TAKE YOUR GAS AND ELECTRICITY METER READING

Monitoring Water Use

LEAK DETECTION GUIDE

Serenbe Green Geothermal Solutions with Bosch Thermotechnology

CONNECTICUT ENERGY PRICE REPORT

Large Power -Secondary 46,50,51 Monthly Charge $ All kwh All kw 18.50

Hybrid (Dual Fuel) - Gas Heat and Air Source Heat Pump

Southern California Edison Revised Cal. PUC Sheet No E Rosemead, California (U 338-E) Cancelling Revised Cal. PUC Sheet No.

Princeton University Microgrid

Heating & Cooling Efficiency

Comparing Fuel Costs of Heating and Cooling Systems

2015 Summary of Electric Rates Last Updated: July 1, 2015

Section 1 Bills Bills Bills All copies of bills and information obtained from company websites

Creating Efficient HVAC Systems

In the average American home, water heating accounts

An Introduction to Natural Gas

Case Studies: Infrared Heating in Industrial Applications

Improving comfort and energy efficiency in a nursery school design process S. Ferrari, G. Masera, D. Dell Oro

RESEARCH HIGHLIGHT. Performance Assessment of a Cold-Climate Air Source Heat Pump

ORDINANCE NUMBER An ordinance to establish electric utility rates in the City of Beatrice, Nebraska, in

Section 2: Estimating Energy Savings and Incentives

Presentation to the Staff Subcommittee on Gas 2010 NARUC Winter Committee Meetings Washington, D.C. February 14, 2010

Example of a diesel fuel hedge using recent historical prices

KU DESIGN GUIDELINES APPENDIX XVI RECOMMENDED BAS I/O CONTROL POINTS BY EQUIPMENT / SYSTEM

Energy Efficiency: Integrated Design and HVAC Systems HEALTHCARE - TOP 5 GREEN BUILDING STRATEGIES

Piedmont Natural Gas Company, Inc. Tennessee Index of Tariff & Service Regulations

THE EUROPEAN GREEN BUILDING PROGRAMME. Technical Module on Combined Heat and Power

SEVEN REASONS FOR ENERGY ACCOUNTING

AUSTIN UTILITIES. CHARACTER OF SERVICE: AC, 60 cycles, 120/240 Volt, three wire, single-phase; or 120 Volt, two wire.

Residential Energy Consumption: Longer Term Response to Climate Change

UTILITIES DEPARTMENT NORTH CAMPUS DISASTER RECOVERY PLAN

CSP. Feranova Reflect Technology. klimaneutral natureoffice.com DE gedruckt

ENERGY EFFICIENCY ENERGY EFFICIENCY: Saving Dollars While Clearing the Air

Energy Management. Electric Procurement Strategies. August 27, 2007

Metering of Individual Units

Do your own home energy audit

WATER. Water Management Protect your building from water damage. Intent. Information & Tips

CHAPTER 9: WATER HEATING

Methodology For Illinois Electric Customers and Sales Forecasts:

HVAC Checklist - Long Form

ELECTRICITY PRICING INFORMATION. This list shows the terms that appear on electricity bills and what they mean:

Teaching Notes. Contextualised task 27 Gas and Electricity

Glossary of Heating, Ventilation and Air Conditioning Terms

Market Potential Study for Water Heater Demand Management

Guidelines for energy efficient heating, ventilation and air conditioning (HVAC) systems

Module 9: 7 Steps for Energy Management

NEW JERSEY CENTER OF EXCELLENCE

Eco-Schools USA Water Audit

Building Energy Systems. - HVAC: Heating, Distribution -

What is Energy? Session 1

Recommendations for Measuring and Reporting Overall Data Center Efficiency

Commercial Gas Heat Pump - VRF

A SOLAR GUIDE - EVERYTHING YOU NEED TO KNOW

Recommendations for Measuring and Reporting Overall Data Center Efficiency

Attached is a link to student educational curriculum on plug load that provides additional information and an example of how to estimate plug load:

Your guide to electricity pricing in Ontario

Data Center Industry Leaders Reach Agreement on Guiding Principles for Energy Efficiency Metrics

COMPARISON OF FIXED & VARIABLE RATES (25 YEARS) CHARTERED BANK ADMINISTERED INTEREST RATES - PRIME BUSINESS*

COMPARISON OF FIXED & VARIABLE RATES (25 YEARS) CHARTERED BANK ADMINISTERED INTEREST RATES - PRIME BUSINESS*

2015 Utility Rates. Electric Garbage Recycling Sanitary Sewer Storm Sewer Water and Yard Waste

Residential Heating Oil Prices: What Consumers Should know

Facts About Home Cooling

EUROPEAN COMMISSION. Energy Audits - Cyprus

A Guide to Net Energy Metering and Your Billing Process

Maximizing Boiler Plant Efficiency. Presenter: Dan Watkins, LEED BD+C Sales Engineer Bornquist, Inc.

PREVENT FROZEN PIPES

Smart Ideas(R) Energy Efficiency Program for ComEd Customers

HOW AN ENERGY EFFICIENT HOME CAN HELP THE ENVIRONMENT

Georgian Bay General Hospital Strategic Energy Management Plan 2014

UTILITY RATE STRUCTURE

MASSACHUSETTS ELECTRIC COMPANY

Transcription:

CHAPTER UNDERSTANDING UTILITY COSTS Utility Bills, Rate Schedules, Data Analysis This section provides information about utility bills and rate schedules, and terminology relating to utility billing. Information about analyzing historical utility consumption data and discussion about possible causes of anomalies or high consumption is also covered in this section. The utilities and services covered in this section include: Electricity Natural gas Oil Propane Water and Sewer Garbage

RESOURCE CONSERVATION MANAGEMENT GUIDEBOOK Electricity The following is an overview of electricity terminology and some insights into electricity use analysis. Figure.1 below is a sample electric bill. The bold italic comments provide explanation of the bill components. Terminology used on the bill, such as demand, is discussed in more detail later in this chapter. FIGURE.1 Sample Electric Bill Rate schedule # Meter number that appears on the front of the meter Present reading Previous reading Present read date ( day period) Previous read date Meter multiplier used Electric consumption (kwh) (Present Read - Prev Read) x Electric demand for this month Reactive power = number of kwh with power factor below 100%* Total amount due for the current month Demand charges Base charge Consumption charges Reactive power charge * Percent may vary with each utility - 1

UNDERSTANDING UTILITY COSTS Electric Meters All electricity used at a facility goes through a meter. Some equipment may have a separate meter, such as for large irrigation pumps, stadium lighting or a scoreboard. In most cases each portable building has its own electric meter. Learn to read your electric meter. This will allow you to spot check the energy consumption. This is done by monitoring the meter to determine the energy consumption for a certain period. For facilities that do not have an energy management control system (EMCS) this approach will allow you to develop daily load profiles for any facility. FIGURE. Consumption kwh Dials on an Electric Meter When reading the meter, if the pointer is between the numbers, read the lower number. 0 1 1 0 0 1 1 0 0 1 kwh Reading 1 0 1 1 0 0 1 1 0 0 1 kwh Reading Load Profile: Chart of electrical demand over time. Usually documents distribution of building heating, cooling and electrical loads. When visiting a facility, read the meter. Then check it again after 10 to 0 minutes to determine the electrical load for that period of the day during that time of year. Spot-checking a meter like this several times during a typical day will help you develop load profiles for each facility. If your facility has electronic digital meters, your utility may be able to provide daily load profiles. Load profiles are useful in understanding how energy is consumed at a facility. This information will become even more important when you begin making purchases in a deregulated energy market. 1 -

RESOURCE CONSERVATION MANAGEMENT GUIDEBOOK FIGURE. Consumption kwh Meters with Demand Kilowatt hour recording dials Decimal point indicator kw demand recording dials Meter seal Meter constant (if any) Meter number kw demand recording arm (black) Kilowatt hour recording dials kw demand recording arm (red) indicates actual demand at that particular time (may not be on same meters) Meter constant (if any) Meter seal Meter number Rate Schedules Electric utilities typically offer several different rate schedules to their customers. These include a residential rate, a commercial rate, a large commercial rate, an industrial rate, an irrigation rate, and sometimes a separate rate for street lighting. Some utilities may have more than one rate that would be applicable for a particular facility. The difference between these rate schedules is that the utility will charge different rates for different chargeables. Residential rates, for example, do not typically charge for electric demand. An industrial rate, on the other hand, may charge for consumption, electric demand and power factor as discussed below. Copies of the different rate schedules that are offered can be obtained from your utility. - 1

UNDERSTANDING UTILITY COSTS FIGURE. Sample Electrical Rate Schedule R R 1 -

RESOURCE CONSERVATION MANAGEMENT GUIDEBOOK Consumption Charge Kilowatt-hour (kwh) This is a charge for the amount of electricity consumed. In the Northwest, rates vary from less than $.01 to more than $.0 per kilowatt-hour (kwh). Most utilities have commercial rate schedules with declining block charges. The more energy you use, the cheaper it gets. For example; first 0,000 kwhs billed at $.0/kWh next 0,000 kwhs billed at $.00/kWh greater than 0,000 kwhs billed at $.01/kWh An increasing block rate does the opposite. The more energy you use, the more it costs per kwh. Declining block rates are more common for commercial customers. Increasing block rates are very rare. Typically, if you do find an increasing block rate, it will be a residential rate schedule. Some utilities have seasonal rates, with the cost per kwh going down during the warmer months. This is because the Northwest is a winter peaking region. Electricity usage goes up in the winter. The basic law of supply and demand causes utilities to charge a higher rate during the winter months, and a lower rate during the summer months. Factors That Can Increase Electrical Consumption Costs 1. Equipment (HVAC, kitchen, etc.) is left on when not needed. The energy management control system (EMCS) is not programmed to match the occupancy patterns. The EMCS battery, which protects the customer-programmed schedules, has failed and the factory installed default program is operating. Providing 100% outside air for ventilation during cold weather conditions. Leaky ducts in electrical HVAC systems. Engine block heaters operating uncontrolled. The meter is read incorrectly. Incorrect multiplier applied to your meter reading - 1

UNDERSTANDING UTILITY COSTS Although not yet common in the Pacific Northwest, utilities are moving toward a less expensive charge for electricity consumed during the off-peak part of a day. For example, between p.m. and a.m. (off-peak hours) the rate per kwh could be $.0 less than the rate for electricity consumed between a.m. and p.m. (peak hours). Such off-peak rates make strategies such as thermal storage and earlier building warm-up more cost effective. As deregulation of electricity becomes more widespread, the option of time of day off-peak rates will become more available. Demand: The rate of electrical usage measured over increments of time (usually 1 or 0 minutes). Measured in kilowatts (kw). Demand Charge This monthly charge is billed for your peak kilowatt (kw) use, averaged over a set time period (usually 1 to 0 minutes). Each month, when the meter is read, the demand indicator is reset to zero. Demand charges in commercial rate schedules vary greatly from no charge to more than $ per kilowatt (kw). Some utilities in the Northwest now offer an off-peak demand rate. Example of an Off-Peak Demand Rate First 0 kw - no charge Everything greater than 0 kw: $0. per kw of billing demand per month during off-peak periods as defined by Bonneville Power Administration $.0 per kw of billing demand per month during on-peak periods as defined by Bonneville Power Administration Some utilities have a ratchet charge on the demand. The highest monthly demand experienced for the year becomes your annual peak. The annual peak is then used to ratchet the monthly demand peaks for the next 11 months. For example, the minimum demand charge for any month is 0 percent of the highest demand in the preceding 11- month period. Demand is a very important target for reduction if your utility has a ratchet clause on the demand. Example of a Ratchet Demand Charge Your demand in December is 00 kw, and you pay $ per kw. You will pay a $,000 demand charge for December. The following June, the demand meter reads 10 kw. You are charged $,00 rather than $0. (0% x 00kW = 0kW, 0kW x $ = $,00) This increase in demand cost of $1,0 ($,00 - $0 = $1,0) is due to the ratchet clause in the rate schedule. This same ratchet will be charged in all the other warm months, even when demand is low. 1 -

RESOURCE CONSERVATION MANAGEMENT GUIDEBOOK APPENDIX A Audits/Surveys R RESOURCE DISK measures.doc: Annotated list of resource conservation opportunities. The list below outlines several situations that can increase electrical demand. If they occur during peak or near peak conditions, they can cause a spike, or sharp increase, in the electric demand. Peak conditions occur when all or most of the facility lighting is on and there is a peak heating or cooling condition, such as morning warm-up during cold weather or afternoon cooling during hot weather. The reference to heating only applies if the heating is electric. A spike in the demand will result in additional costs on the utility bill and, with some utility rate schedules, may impact demand charges year round. Factors That Can Increase Demand Costs 1. Turning on football field lighting if it s on the same meter as adjacent facilities*. Operating electric kiln*. Operating a large motor such as on a sump pump or sewage lift station*. Turning on all the electric resistant heating units at the same time during warm-up. Extensive use of portable electric heaters. Providing 100 percent outside air for ventilation during cold weather conditions. A large electric domestic hot water tank that operates all (or most) heating coils any time it heats water. Starting all the kitchen electric ovens simultaneously. Starting engine block heaters simultaneously 10.The meter is read incorrectly 11. Incorrect multiplier applied to your demand reading * if during facility peak load periods Base or Basic Charge The base charge is a minimum cost of service charged for each utility meter. A commercial base charge can range from less than $ to well over $100 per month. The base charge could become important for those services that are not used for several consecutive months, such as field lighting or irrigation pumping. It may be cost-effective to cancel service to save the base charge for the months of non-use. The re-activation charge should also be considered in your cost-effectiveness calculation. - 1

UNDERSTANDING UTILITY COSTS RA APPENDIX Technical Information: See Reducing Power Factor Cost for a more complete explanation R of power factor Power Factor Power factor is a measure of the apparent power compared to the real power. This can be a difficult concept to understand. The important thing to note is that utilities will charge extra if a facility has a power factor problem (for example, below 0 percent). It may show up on the bill as KVAR HOURS or PFA (Power Factor Adjustment). Facilities with a large number of motors, light fixtures with magnetic ballasts and other equipment that have capacitors, can have significant power factor charges. Some plug-in items, such as computers, can also have a negative impact on the power factor of a facility. If power factor is a big problem, you can install components on the electrical distribution system of a facility to help correct the problem. These devices can be quite expensive. But they may be cost-effective if power factor charges are a significant part of the bill. Contact your utility representative to discuss options for correcting power factor problems. Analyzing Electric Utility Data Electrical use profiles from different facilities can have different shapes based on the type of heating (electric or gas) and cooling equipment (if any), and the other electric loads (computers, pumps, dryers, etc.) Base Load: Demand for electricity which is consistent and is unaffected by variables such as seasonal climate. Variable Load: Demand for a resource which fluctuates over a period of time, usually a year. Base load consists of non-weather dependent loads such as lighting, fans, plug loads (computers, etc.) and electric domestic hot water. Variable loads are typically weather related, such as heating and cooling loads. Other loads that could be considered part of the variable load are loads that are not a part of normal operations (electric kilns) and seasonal loads (stadium lighting). You can better determine areas of potential savings by graphically displaying monthly electric consumption and electric demand profiles. Figure. illustrates a demand and consumption profile with base and variable loads. 1 -

RESOURCE CONSERVATION MANAGEMENT GUIDEBOOK FIGURE. Sample Annual Demand and Consumption Profile Consumption: 0,000 Demand: 00 00 00,000 00 Variable load 00 10,000 00 kwh 100,000 00 00 Base load 0,000 00 100 Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec Consumption Demand This is the profile of an all-electric school. Note that the consumption and demand are both high in the winter. However during the summer, consumption fell but demand rose. This was caused by cooling equipment used on just a couple of hot days. Even brief peaks can affect overall monthly demand, increasing costs. April and October are very close to representing the base load because minimal heating and cooling happens during those months. If this were a gas-heated facility, there would be much lower electrical consumption and demand during the winter. Electrical consumption would increase some during the winter due to longer periods of lighting and use of electric resistance heaters. -10 1

UNDERSTANDING UTILITY COSTS Natural Gas The following is an overview of gas terminology and some insights into gas use analysis. Therms The therm is a unit of measure related to natural gas consumption. One therm is equivalent to 100,000 British thermal units (Btu). Like electricity, gas rate schedules for commercial accounts typically have a declining block rate. The more you buy, the cheaper it gets. Base Charge Similar to electricity, natural gas has an associated base charge or meter charge. This will vary depending on the utility and the size of the meter. If operations have changed significantly at a facility and a smaller meter could be installed, there may be considerable savings in base charges. If the operation is seasonal, such as an outdoor pool, there may be some advantage to canceling service during periods of non-use. If you consider this approach, include the cost of re-activation in your cost-effectiveness calculation. Rachet Charge Some natural gas utilities have a ratchet on consumption. The charge in the rate schedule is based on a percent (say 0 percent) of the highest month s consumption in the past 11 months. This type of rate schedule is typically reserved for large commercial users and is designed for facilities with a relatively even annual load. If, for example, a facility uses 0,000 therms during the coldest winter month, this would then set the charge for the next 11 months. During the summer months the boilers are turned off and gas is only used for some kitchen equipment and some domestic hot water heaters. The consumption may drop to,000 therms for a month. However, because of the 0 percent ratchet clause on the rate schedule, the facility is charged for,000 therms (0,000 x 0%). Study rate schedules and your facility gas use profiles closely to determine which rate schedule is best for each facility. Firm vs. Interruptable Natural gas companies are limited in their capacity to deliver gas by the capacity of the main gas transmission lines. During extremely cold conditions, shortages can occur. To accommodate customers with different needs, gas companies offer gas as a firm or interruptable commodity. A firm gas rate costs more than an interruptable rate. If you select a firm rate schedule, the utility will 1-11

RESOURCE CONSERVATION MANAGEMENT GUIDEBOOK not cut service to you due to high regional demands for gas. Some gas companies offer different degrees of interruptability. Those customers interrupted first, as specified in the rate schedule, will likely pay the lowest price for gas. The price for interruptable gas is typically 1 to 0 percent less than firm gas, depending on the volumes used and the local gas company. Facilities that have, or can add, a back-up source of fuel (such as oil or propane) should consider buying interruptable gas. In the Northwest, gas interruptions have been rare. However, if you are on an interruptable rate, are notified of a curtailment, and you can t comply because your back-up systems are not working, you will pay a penalty as specified in the rate schedule. Factors That Can Increase Natural Gas Consumption Costs 1. Equipment is left on when not needed (is uncontrolled). The energy management control system (EMCS) is not programmed to match the occupancy patterns. The EMCS battery, which protects the customerprogrammed schedules, has failed and the factory installed default program is operating. HVAC system is providing 100 percent outside air for ventilation during cold weather conditions. Leaky ducts in gas-fired ducted systems. Gas kitchen equipment operating when not needed. There is a major leak in the heating distribution lines from steam or hot water boilers. The meter is read incorrectly. Incorrect multiplier is applied to your meter reading -1 1

UNDERSTANDING UTILITY COSTS Fuel Oil Fuel oil is typically sold in gallons. The two most common types of oil sold are # or diesel, which is a light oil and # or bunker C which is a heavy residual oil. The bunker C oil typically requires a heater to keep the viscosity low in the storage tank. Boilers that use the heavy oil usually have a second heater (electric) at the burner to further heat the oil before combustion. Because oil is sold by individual dealers, the price can vary. Usually, the larger the volume purchased, the lower the price per gallon. For customers with large tanks (more than 10,000 gallons) the price reduction can be significant. If you have a large oil-heated facility (greater than 0,000 square feet), it may be worthwhile to purchase oil on a contract that is put out for bid. Establishing a contract based on low bid will provide the best price as well as a price guarantee. Be sure to specify the type of oil needed. Low sulfur oil is the best, but is more expensive. Also check the reliability of the bidders. R RA APPENDIX See Helpful Contacts for a contact number. There may be other options available to get a good price for oil. It may be available to your organization through your state procurement office, such as the Department of General Administration, Office of State Procurement (OSP) in Washington State. OSP contracts with suppliers to get a good price for state facilities and other public entities that subscribe to OSP. To track oil consumption, have a facility operator or maintenance staff stick the tank (check the level) daily or at least weekly, at about the same time, and record the level. This will allow you to profile consumption and make it easy to recognize problems that may occur. Factors That Can Increase Oil Consumption Costs 1. Equipment is left on when not needed (is uncontrolled). The energy management control system (EMCS) is not programmed to match the occupancy patterns. The EMCS battery, which protects the customerprogrammed schedules, has failed and the factory installed default program is operating. HVAC system is providing 100 percent outside air for ventilation during cold weather conditions. There is a major leak in the heating distribution lines from steam or hot water boilers. A leak in the underground tank or lines to the boiler 1-1

RESOURCE CONSERVATION MANAGEMENT GUIDEBOOK Propane Factors that can increase propane consumption are the same as those for oil. APPENDIX RA See Helpful Contacts for a contact number. Propane or LPG (low pressure gas) is sold in gallons and is provided by a dealer. Some dealers have tanks available to lease. However, leasing the tank locks you into a commitment to one dealer and often a higher price. Unlike oil, propane tanks are always above ground. Customers with large tanks (greater than 10,000 gallons) usually can get a very good price. If your facility is large enough, pursue a bid price for the best deal. There may be other options available to get a good price for propane. It may be available to your organization through your state procurement office, such as the Department of General Administration, Office of State Procurement (OSP) in Washington State. OSP contracts with suppliers to get a good price for state facilities and other public entities that subscribe to OSP. Water and Sewer Water is typically sold by the local municipality. It can be sold in several different units. Hundreds of gallons, thousands of gallons, hundreds of cubic feet and acre feet are the most common. Although water is usually relatively inexpensive, local or seasonal water issues may impact the cost of your water. Penalties can also be incurred if you don t abide by restrictions during critical water periods. If your facilities are connected to a municipal wastewater system, sewer charges are usually based on the water consumption read from the meter. The reason for this is that water used at your facilities will end up in the sewer. Sewer rates can vary greatly depending on the type of wastewater treatment provided. Some sewer rates are more than four times higher than the water charge. Make-Up Water: Water added to the system due to leaks, evaporation, blow-down or consumption (eg. humidifiers). Water uses that bypass the sewer are: Irrigation Most cooling tower make-up water Most boiler water make-up Condenser water that empties to a storm drain not connected to the sewage treatment plant -1 1

UNDERSTANDING UTILITY COSTS FIGURE. Sample Water Meters ROUND 10,000 STRAIGHT 0 1 0 0 1 100,000 1,000 0 0 1 1 0 1 CUBIC 0 FOOT 1 0 1 1,000,000 100 ONE FOOT 10 For these uses, a separate meter or a submeter may be appropriate. Negotiate with your water provider to establish an agreement that allows for water that does not go to the sewer. A submetered water volume could be subtracted from the main meter reading to give a corrected volume for sewer charges. If this kind of disparity has been going on for some time (i.e. sewer charges on irrigation water), you may be able to negotiate a refund. Factors That Can Increase Water Consumption Costs 1. Leaks (domestic use or irrigation). Incorrect reading of the water meter. Plumbing fixtures stuck in the on (or flush) position. Auto-flush urinals with high-volume flushing 1-1

RESOURCE CONSERVATION MANAGEMENT GUIDEBOOK Garbage Garbage service can be provided by public or private entities. For commercial-sized facilities, dumpsters are usually provided, and the charge is based on the volume of the dumpster used and the number of times emptied per week. The unit of measurement is usually cubic yards. Garbage service charges can be significant. APPENDIX RA Audits/Surveys.Conducting Waste Characterizations: How to conduct waste characterizations. R RESOURCE DISK wst_char.xls: Waste Characterization Data Sheet. Before you consider using a trash compactor as a way to reduce volume and costs, check with your refuse hauler. Garbage may be charged on a weight basis as well, and the compactor will not reduce the weight, only the volume. You could get a price break for fewer pickups. However, you may not get a reduction for a smaller dumpster if you are compacting and the facility remains on the same pick-up schedule. Many garbage service providers also provide free recycling pickup. Separation of recyclable materials coupled with reduction in the dumpster size and/or pickup schedule can lead to substantial savings. Factors That Can Increase Garbage Costs 1. Illegal or unauthorized dumping into facility dumpsters. Service provided for partially filled or empty dumpsters. Recycleable items in the garbage -1 1