PORTABLE AIR CONDITIONER



Similar documents
Portable Air Conditioner

NewAir AC-10100E / AC-10100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

NewAir AC-10000E, AC-10000H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR

Use and Care Manual. Model CPA12KH AIR CONDITIONER

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CCS. Voltage rating: 115V~60Hz Power rating : 1400W

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MF08CESWW. Voltage rating: 115V~60Hz Power rating : 800W

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MN12CES / MN10CESWW

NewAir AC-14100E / AC-14100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

Important Safeguards

PORTABLE AIR CONDITIONER (LOCAL)

Air Conditioner P O R T A B L E. Instruction Manual. Your Guarantee. For model WA-1220M WA-1220H, WA-1220E. Portable Air Conditioner / Heater

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CHCSCS

USER S MANUAL HSC-24A

ACW200C / ACW200CH. Innovative AutoDrain Technology. Owner s Manual Portable Air Conditioner with Heat

Meaco 30L and Meaco 40L dehumidifier instruction manual

USER INSTRUCTIONS FOR 10 LITRE PORTABLE DEHUMIDIFIER MODEL NO. DHMD102

Air Conditioner. Portable BTU/h 2.9kW INSTRUCTION MANUAL CWAC11 CPIN Important! Please read these instructions carefully.

Please read this owner s Manual carefully before operating the unit. - Cooling - Heating - Dehumidifying - Fan

SILENT10 PORTABLE AIR CONDITIONER USER MANUAL

Room Air Conditioners

Portable Air Conditioner INSTRUCTION MANUAL

USER S MANUAL FH052EAV1 FH070EAV1. System Air Conditioner (Cooling and Heating) ENGLISH ESPAÑOL FRANÇAIS ITALIANO PORTUGUÊS DEUTSCH E HNIKA

PORTABLE AIR CONDITIONER

Vertical Display and Storage B SKOPE Gen2: Three Door Chiller

Operating Instructions Air Conditioner

Split Type Room Air Conditioner. KSWM units

Air Conditioner Water Heater - A Product of HotSpot Energy LLC

Dehumidifier D 850E. - Instruction manual version 02

Instruction manual for Firstline FCS12000CH

To suit Daikin FDY "F" Series and FD "F" Series. (and other models incorporating BRC1B62/52 Remote Controller)

Portable Evaporative Air Cooler. OWNER S MANUAL Read and save these instructions before use. Model: CL30XC

2KW CERAMIC HEATER DHCER20. User Manual

Get Me Cool Now Portable Air Conditioner User s Manual

ENGLISH INSTRUCTION & INSTALLATION MANUAL DUCTLESS MINI SPLIT AIR CONDITIONING SYSTEMS

OWNER'S MANUAL R-410A Duct Free Split System Air Conditioner and Heat Pump

SERVICE MANUAL. Room Air Conditioner Multi Split Wall-Mounted Type Indoor. FSAI-Pro-91AE2 FSAI-Pro-121AE2 FSAIF-Pro-181AE2

REMOTE CONTROL MANUAL

SAFEGUARDING THE ENVIRONMENT

OWNERS MANUAL. PAC 210 U Portable Windowless Air-Conditioner

Service manual. Website: CAUTION - BEFORE SERVICING THE UNIT, READ THE SAFETY - PRECAUTIONS IN THIS MANUAL.

floater imports DF169 ECO AIR COOLER EVAPORATIVE AIR COOLER WITH IONIZER USER S MANUAL

SPLIT WALL MOUNTED TYPE AIR CONDITIONERS OWNER'S MANUAL

WALL MOUNTED SPLIT TYPE AIR CONDITIONER

OPTIONAL SLENDER REMOTE CONTROL

Room Air Conditioners

Operating Instructions Air Conditioner

INDOOR UNIT/OUTDOOR UNIT

LG Multi Type Air Conditioner

WINDOW ROOM AIR CONDITIONER

Owner s Manual. SRCOOL12K (120V, 60 Hz) SRXCOOL12K (230V, 50 Hz) Portable Air Conditioning Unit. Introduction 2. Important Safety Instructions 2

Taurus Series YORK Window Air Conditioners

Platinum Range PLAC12000HP PORTABLE AIR CONDITIONER WITH HEAT PUMP USER MANUAL HIGH MID COLL HEAT DRY FAN LOW F C TIMER SLEEP SWING

ALL IN ONE. Heat Pump Water Heater

IMPORTANT INSTRUCTIONS & OPERATING MANUAL. Houston 50 Inch Electric Wall Mounted Fireplace Black / White

ICE AIR. Console Water Source Heat Pump (WSHP) OPERATING & MAINTENANCE MANUAL. Wo r l d C l a s s C o m f o r t.

USER S MANUAL. Duct Type Series. Free Joint Multi Air Conditioner (Cooling and Heating) FUEA Series E S F I P D G DB A(1) ENGLISH ESPAÑOL

Dehumidifier Users manual. For Models: DH45S DH65S

AN500T, AN1000, AN1000T, AN1500, AN1500T AN2000, AN2000T

Room Air Conditioners

LG Room Air Conditioner OWNER'S MANUAL

Operating Instructions Split System Air Conditioner

FOXAIR 60/50 ALL MODELS

Portable Evaporative Air Cooler for Indoor Use. OWNER S MANUAL Read and save these instructions before use. Model: CL25AE

BD150 INDUSTRIAL DEHUMIDIFIER USER MANUAL

Microwave Oven. Warning: a) This oven is not for commercial use. b) Don't open the cover of the machine except professional person.

WHYNTER ECO-FRIENDLY 14,000 BTU PORTABLE AIR CONDITIONER WITH HEATER

Before using your air conditioner, please read this manual carefully and keep it for future reference. ROOM AIR CONDITIONER

FT-100 Fire Training Fog Machine User Manual English

Climax Air Inc. DC Inverter Portable Air Conditioner Model VS12 12,000 BTU Introducing The World s Most Efficient Portable Air Conditioner

LG Wireless Remote Controller

Inverter Single Zone Ductless Mini Split Heat Pump

Single Day Alarm Clock with. Bluetooth and USB Play-through

Bench Autoclave. Standard Operating Procedure. For Installation, Use and Maintenance

Contact Details. Please note that some of the contact details on this PDF document may not be current.

Split Air Conditioner

the Soft Top Breville Customer Service Center Instruction Book - Livret d instructions

Operating instructions in the back. PD1020L

USER S INFORMATION MANUAL

Air Conditioning System

AIR CONDITIONER OWNER S MANUAL. Please read this manual carefully before operating your set and retain it for future reference.

OWNER S MANUAL VMH 09/12/18/27/36 InverterFlex

CARING FOR YOUR WATER HEATER

evo + HIGH-WALL DUCTLESS AIR CONDITIONING & HEATING SYSTEM OWNER S MANUAL Models: GWH09AB-D3DNA2D GWH18AC-D3DNA2D GWH24AC-D3DNA2D

MICA HEATER INSTRUCTION MANUAL Model No: UHM V 50Hz 2200W

EVAPORATIVE AIR COOLER INSTRUCTION MANUAL

IMPORTANT SAFETY INSTRUCTIONS WARNING READ AND SAVE THESE OPERATING AND SAFETY INSTRUCTIONS BEFORE USING THIS HEATER.

DAIKIN ROOM AIR CONDITIONER MODELS. Operation Manual ENGLISH ESPAÑOL TURKISH

DAIKIN ROOM AIR CONDITIONER FT50BSG FT60BSG MODELS. Operation Manual

Si10-417_C. Pocket Manual. Service Diagnosis SPLIT & MULTI

Portable Air Conditioner

LG Floor Standing-Type Air Conditioner OWNER'S MANUAL

Reverse Cycle Inverter Split System Air Conditioner

GenStore Archive Cabinet

Failure code manual. content

Wine Cooler with Thermo-Electric Cooling & Heating Technology

Instruction Manual. Image of SP-3015 & SP Important Safeguards. Automatic Dispensing Hot Water Pot with Reboil Function

AIR CONDITIONER (SPLIT TYPE)

Portable Evaporative Air Cooler with Heater for indoor use. OWNER S MANUAL Read and save these instructions before use.

R410A SPLIT SERIES DC INVERTER

Transcription:

VERY IMPORTANT! MODEL: GDC-AC9RW / GDC-AC9RCS GDC-AC9RCW / GDC-AC12RW GDC-AC12RB / GDC-AC12RCB GDC-AC12RCW INSTRUCTIONS FOR USE PORTABLE AIR CONDITIONER Do not install and use your portable air conditioner unit before carefully reading this instruction manual. Please retain this manual for product warranty and future reference CAUTION! 1." DO NOT BLOCK VENTILATION "! Please make sure the inlet and outlet ventilation is not blocked at all times. 2. Operate this unit on a horizontal surface to avoid water leakage. 3. Do not operate this unit in an explosive or corrosive atmosphere. 4. Operate this unit in an ambient of 32 degree centigrade or less when the unit is in the cooling function. Contrarily, when the unit is in the heating function, the ambient temperature is less 23 degree centigrade 5. Clean the air filter periodically to enjoy the most efficient cooling. 6. When the unit is turned off, please wait at least 3 minutes before restarting it. This is to prevent the compressor from being damaged. 7. This unit needs at least 10 Amps of electricity to have its compressor operational. Please do not use any extension cords with this unit. 8. This unit is for indoor operation only. 9. Make sure the adjustable air vent is open, and also the exhaust pipe and drain pipe are removed and extended to the closest window before using. 10.When the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid hazard. 11.The batteries must be removed from the appliance before it is scrapped and that they are disposed of safely. 12. This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. 13. Children should be supervised to ensure that they do not play with the appliance. 1

CONGRATULATIONS ON YOUR SELECTION OF A QUALITY PORTABLE AIR CONDITIONER PORTABLE AIR CONDITIONER Your Air Conditioner has been designed and manufactured to the highest standards of modern engineering. One of its many features is a remote control device which allows you to control all functions conveniently. - Moves easily from room to room on easy glide castors - No installation required-just plug into any household 10 Amp power outlet - Refrigerated air system designed to cool instantly whenever you want it - Heated air system design heats instantly whenever you want it - Dehumidified filtered air cycle for improved breathing conditions due to the powerful dehumidification process -If the remote control function is not required, your one touch electronic pad provides easy to identify manual operation -24 hour programmable timer that can be used with either the air conditioning or dehumidification setting -Unique sleep control function -220-240 Volt 50Hz operation -1.6 meter cord with plug UNPACKING INSTRUCTIONS 1. Place the unit in the correct upright position before unpacking. 2. Cut the two packing straps. 3. Slide the carton in an upwards motion and it will release from the base. 4. Grip the carry handles located on either side of the unit and carefully lift until it slides out of the foam base. CONTENTS 1 / Air control unit 2 / 1-remote control unit 3/ Window kit 2 3

NAMES OF THE PARTS TACK SWITCH & DESCRIPTION OF FUNCTION 1. Tack switch 2. Display screen 3. Adjustable air vent 4. Joint tube 5. Exhaust tube 6. Drain hose 1. POWER KEY Press to turn unit "ON" or "OFF". 2. FUNCTION Press this key to select refrigeration, heat or dehumidification. ( heating function just for model number GDC-AC9RCS/ GDC-AC9RCW/ GDC-AC12RCB/ GDC-AC12RCW) 3. TEMPERATURE REGULATION KEY (UP) This key raises the preset temperature by 1 each time it is pressed to a maximum of 30 7. Cool inlet 8. Cool Air filter 9. Hot inlet 10. Drain pipe 11. Hot air filter 4 4. TEMPERATURE REGULATION KEY (DOWN) This key lowers the preset temperature by 1 each time it is pressed to a minimum of 15 or 17 ( For GDC-AC9RW/GDC-AC12RW/GDC-AC12RB, the minimum is 15, for GDC-AC9RCS/GDC-AC9RCW/GDC-AC12RCB/GDC-AC12RCW, the minimum is 17 ) In normal conditions, the temperature data which appears on the panel is the ambient temperature, not the temperature which is set by the user. When the user has adjusted and set the temperature to his requirement, the data on the panel will return to the ambient temperature 5 seconds later. The ambient temperature will descend or change according to the temperature which is set by the user, but the temperature descendant time and speed will depend on the environment and space where the model is. For example, if the ambient temperature is too hot or the room is too large, the speed for the temperature descent is absolutely slow, and the cooling efficiency will be poor as well. 5

5. L.E.D. DISPLAY Indicates the temperature or the time setting. After any time set the display will return to the preset temperature automatically. Error Display E1: Indicates open circuit or short circuit in room temperature sensor. E2: Indicates open circuit or short circuit in pipe temperature sensor. E7: Indicates the water is full inside. Please contact a authorized service centre if any of the above error messages are shown. 6. SPEED Press to select either LOW, MEDIUM, HIGH or AUTO fan speed. If "AUTO" is selected, the unit operates at maximum cooling capacity when the room temperature less the set temperature is above 2. When the room temperature less the set temperature is below 2, the unit operates at middle cooling capacity. When the room temperature equal the set temperature, the unit operates at minimum capacity. If "HIGH" is selected, the unit operates at maximum cooling capacity no matter what the setting temperature is. The "MEDIUM" OR LOW" comes to the same. 7. PROGRAMMABLE Programmable timer ON/OFF key. TIMER TIMER-ON: The timer-on is used to turn on the unit automatically after the set time is over. (Timer-on key is correspond to the functional indicator light) 1. Press the "TIMER" key at stand-by status to set the time. Choose the function desired(refrigeration, heat or dehumidification.) 2. Once the set hour has come to an end, the unit will turn on automatically. 3. Press the "POWER" key before time out, the setting time will be cancelled and the unit will turn on. TIMER-OFF: The timer-off is used to turn off the unit automatically after the setting time is over. 6 8. SLEEP CONTROL When setting the "sleep comfort" mode please ensure that you FUNCTION then set the number of hours required and press the timer button till those hours are indicated on the L.E.D display. After setting the hours the L.E.D. display will automatically return to the current pre-set temperature. To increase this setting press the "UP" button for each press, the temperature will be increased by 1. Likewise to set for a lower temperature, press the button indicating DOWN, and for each press the temperature will be decreased by 1. During the course of this cycle, to ensure maximum sleep comfort. the micro-processor memory will raise the pre-set temperature 0.5 each half hour to a maximum of 2 over two hours and then maintain that temperature for the balance of the time set. The portable air conditioner is fitted with a 3 minutes compressor delay protection circuit which simply means that the compressor requires 3 minutes to start. From either being switched on, or when changing from dehumidify to any air conditioning cycle chosen. 9. E7 When the unit warns of full water, please unplug the water stopper at the back of the unit and then lean the unit to drain the water out. Then the unit can be restarted. If the E7 is presented again, please find a specialized person to repair. Note: Heating function does not operate if the ambient temperature is over 23. GDC-AC9RCS/GDC-AC9RCW/GDC-AC12RCB/GDC-AC12RCW with heating function 7

REMOTE CONTROL FUNCTION INSTALLATION Install the portable air conditioner in a flat and spacious location where the air inlets and outlets will not be blocked. A minimum clearance of 40cm from a wall or other obstacles should be kept (as below picture). The appliance should not be used in the laundry. 1. POWER 2. FUNC 3. TIMER 4. AUTO 5. HI 6. MID 7. LOW 8. SLEEP 9. TEMP. Stop/Start switch Function MODE selector Hourly programming Automatic fan speed High fan speed Medium fan speed Low fan speed Night operation selector Temperature selector NOTICE This unit can evaporate the condensation and flow out through the exhaust hose automatically when the unit is in the cooling function. Contrarily when the unit is in heating function and the water level reaches the detected level, it will begin to pump for sixty seconds. After sixty seconds of pump function, if the water level is still on the detected level, the unit will stop working and present "E7" warning. Then after three seconds of relieving malfunction, the unit will rework automatically. Please make sure that the rubber cap is locked on the drain hose, and also the exhaust pipe and the drain pipe to be extended to the closest window when the unit is running. 8 9

To remove the air filter, please follow the arrow direction and push the filter lightly. Then take out the filter for cleaning. MAINTENANCE PLEASE DISCONNECT THE POWER CORD BEFORE. AIR FILTER The air filter located on both sides of the unit can be removed, simply by pulling the frame in an upward motion. CONDENSER/EVAPORATOR Use a brush attachment with a vacuum cleaner. CABINET Wipe with a damp cloth and polish with a soft cloth. POWER SUPPLY (1) Confirm the correct power. (2) Insert the plug into the outlet firmly. In case of a dangerous leak, prevent the AC cord from scarring. (3) Don t pull the power wire by force because it will cause damage to the power wire. PLACE FOR USE (1) Because the machine exerts hot air, please don t operate it in a narrow place. (2) In case of dangerous leak, don t work the machine in a humid place. (3) Don t place the machine in a sunlit corner otherwise the colors soon fade out of the machine. 10 11

HELPFUL HINTS The unit is fitted with a special thermal cut off device. When selecting the refrigerating function, The unit should operate in room temperatures between 17-32, and when selecting heating function, the room temperature must less than 23 and above 7. Please ensure the unit is not placed against objects which will obstruct air intake e.g. furniture or curtains as this will affect it's performance drastically. Do not place the unit in direct sunlight, as this may cause the unit to overheat and turn off. EXHAUST PIPE AND DRAIN PIPE To remove exhaust pipe, press slightly and pull away from the unit. Picture indicates the removal of the exhaust pipe. Made sure the exhaust pipe and the drain pipe to be extended to the closest window. TROUBLE SHOOTING Never try to repair or dismantle the air conditioner unit yourself. Incompetent repairs result in loss of warranty and can endanger the user and the property. Problem Cause Solution The air conditioner does No power supply. Connect to a functioning outlet and switch on. not function. The alarm light is on. Empty the internal water container. Timer function is active. Deactivate TIMER function. The air In direct sunlight. Close curtains. conditioner does not seem to Windows or doors open, many people or a heat Close doors and windows, place an extra air conditioner. perform. source in the room. Dirty filter Clean the filter(s). Air inlet or air outlet blocked. Remove the blockage. Room temperature lower than the selected value. Change temperature selection. The unit is noisy. Unit is not level. Place on an even, solid surface (less vibrations.) The compressor does not work. The remote control does not function. The overheat protection is probably activated. Distance too long. Remote control signal not detected by the control panel. The batteries are drained Wait 30 minutes until the temperature has decreased, then turn the unit on again. Make sure the remote control is correctly aimed at the control panel. Replace the batteries. To correct problems not mentioned in the table and/or if the recommended solutions fail to solve the problem, please contact an authorized service centre. 12 13

SPECIFICATIONS Model No. GDC-AC9RW GDC-AC12RW / GDC-AC12RB Power Source 220-240V~ 50Hz AC 220-240V~ 50Hz AC Power Consumption 1080W 1452W Max Power 1250W 1480W Cooling Capacity 2600W 3500W Air Flow 400 M 3 /H 420 M 3 /H De-humidifier (30,80%) 1.6L/hr 2.5L/hr Refrigerant R410A R410A For room size up to 20 m 2 25 m 2 Dimensions (mm) 476Wx358Dx840H 476Wx358Dx840H Net Weight 28.5KG 29.5KG Model No. GDC-AC9RCW/GDC-AC9RCS GDC-AC12RCW/GDC-AC12RCB Power Source 220-240V~ 50Hz AC 220-240V~ 50Hz AC Power Consumption Cooling / Heating 1080W / 1245W 1452W / 1500W Max Power Cooling / Heating 1250W / 1350W 1480W / 1530W Cooling Capacity 2600W 3500W Heating Capacity 3000W 3700W Air Flow 400 M 3 /H 420 M 3 /H De-humidifier 1.6L/hr 2.5L/hr (30,80%) Refrigerant R410A R410A For room size up to 20 m 2 25 m 2 Dimensions (mm) 476Wx358Dx840H 476Wx358Dx840H Glen Dimplex Australasia Ltd Glen Dimplex Australia Pty Ltd 38 Harris Road, East Tamaki, 2/205 Abbotts Road, Manukau, Auckland 2013 Dandenong sth 3175, Victoria, New Zealand Australia Ph: 0800 666 2824 Ph: 1300 556 816 Fx: 0800 112 020 Fx: 1800 058 900 Net Weight 29.5KG 30.5KG 14 15