Policy Number Reimbursement Policy 160.24 Approved By UnitedHealthcare Medicare Reimbursement Policy Committee Current Approval Date 06/10/2015 IMPORTANT NOTE ABOUT THIS REIMBURSEMENT POLICY This policy is applicable to UnitedHealthcare Medicare Advantage Plans offered by UnitedHealthcare and its affiliates. You are responsible for submission of accurate claims. This reimbursement policy is intended to ensure that you are reimbursed based on the code or codes that correctly describe the health care services provided. UnitedHealthcare reimbursement policies use Current Procedural Terminology (CPT *), Centers for Medicare and Medicaid Services (CMS), or other coding guidelines. References to CPT or other sources are for definitional purposes only and do not imply any right to reimbursement. This reimbursement policy applies to all health care services billed on CMS 1500 forms and, when specified, to those billed on UB04 forms (CMS 1450). Coding methodology, industry-standard reimbursement logic, regulatory requirements, benefits design and other factors are considered in developing reimbursement policy. This information is intended to serve only as a general resource regarding UnitedHealthcare s reimbursement policy for the services described and is not intended to address every aspect of a reimbursement situation. Accordingly, UnitedHealthcare may use reasonable discretion in interpreting and applying this policy to health care services provided in a particular case. Further, the policy does not address all issues related to reimbursement for health care services provided to UnitedHealthcare enrollees. Other factors affecting reimbursement may supplement, modify, or, in some cases, supersede this policy. These factors may include, but are not limited to legislative mandates, the physician or other provider contracts, and/or the enrollee s benefit coverage documents. Finally, this policy may not be implemented exactly the same way on the different electronic claims processing systems used by UnitedHealthcare due to programming or other constraints; however, UnitedHealthcare strives to minimize these variations. UnitedHealthcare may modify this reimbursement policy at any time by publishing a new version of the policy on this Website. However, the information presented in this policy is accurate and current as of the date of publication. *CPT copyright 2010 (or such other date of publication of CPT) American Medical Association. All rights reserved. CPT is a registered trademark of the American Medical Association. Proprietary information of UnitedHealthcare. Copyright 2015 United HealthCare Services, Inc. Table of Contents Application...2 Summary...2 Overview...2 Reimbursement Guidelines...3 CPT/HCPCS Codes...4 ICP/PCS Codes...5 References Included (but not limited to):...7 CMS NCD(s)...7 CMS Article...7 CMS Benefit Policy Manual...7 CMS Claims Processing Manual...7 MLN Matters...7 UnitedHealthcare Medicare Advantage Coverage Summaries...7 UnitedHealthcare Medical Policies...7 Others...7 History...7 Proprietary information of UnitedHealthcare. Copyright 2015 United HealthCare Services, Inc. Page 1
Application Reimbursement Policy This reimbursement policy applies to services reported using the Health Insurance Claim Form CMS-1500 or its electronic equivalent or its successor form, and services reported using facility claim form CMS-1450 or its electronic equivalent or its successor form. This policy applies to all products, all network and non-network physicians, and other health care professionals. The HCPCS/CPT code(s) may be subject to Correct Coding Initiative (CCI) edits. This policy does not take precedence over CCI edits. Please refer to the CCI for correct coding guidelines and specific applicable code combinations prior to billing UnitedHealthcare. It is not enough to link the procedure code to a correct, payable ICD-9-CM diagnosis code. The diagnosis must be present for the procedure to be paid. Compliance with the provisions in this policy is subject to monitoring by pre-payment review and/or post-payment data analysis and subsequent medical review. The effective date of changes/additions/deletions to this policy is the committee meeting date unless otherwise indicated. CPT codes and descriptions are copyright 2010 American Medical Association (or such other date of publication of CPT). All rights reserved. CPT is a registered trademark of the American Medical Association. Applicable FARS/DFARS restrictions apply to Government use. Fee schedules, relative value units, conversion factors, and/or related components are not assigned by the AMA, are not part of CPT, and the AMA is not recommending their use. The AMA does not directly or indirectly practice medicine or dispense medical services. The AMA assumes no liability for data contained or not contained herein. Current Dental Terminology (CDT), including procedure codes, nomenclature, descriptors, and other data contained therein, is copyright by the American Dental Association, 2002, 2004. All rights reserved. CDT is a registered trademark of the American Dental Association. Applicable FARS/DFARS apply. Summary Overview Essential tremor (ET) is a progressive, disabling action tremor (also referred to as a kinetic or postural tremor) which most often affects the hands during sustained arm extension or during voluntary motion such as writing or pouring. ET may also affect the head, voice, and legs and affects more than one million patients in the U.S. Although ET may start at any age, there appears to be a bimodal distribution peaking in the second and sixth decades. ET affects men and women equally and while its precise pathogenesis is unknown, it does occur genetically in some families as an autosomal dominant trait. Pharmacotherapy is the first line treatment of ET and may improve function by reducing the severity of tremor. However, certain patients do not adequately respond to or cannot tolerate these medications. Thalamic Deep Brain Stimulation (DBS) may be helpful for carefully selected individuals with marked tremor causing significant functional disability that is refractory to optimal medical therapy. Parkinson's disease (PD) is an age-related neurodegenerative disorder, characterized by tremor, rigidity, bradykinesia (gradual loss of spontaneous movement) and progressive postural instability. PD effects up to one million Americans. The primary underlying abnormality in PD is the progressive loss of dopamineproducing cells in the brain, leading to an imbalance of dopamine and acetylcholine, the normal neurotransmitters in the corpus striatum. The most common form, idiopathic PD, begins most often between ages forty five to sixty five, with average onset at age fifty-eight. The cause of PD remains unknown, although proposed theories include the role of genetic and certain environmental factors. For patients who become unresponsive to pharmacological treatments and/or have intolerable drug side effects, DBS may be helpful; DBS requires the stereotactic placement of an indwelling electrode in the brain. This treatment for PD supports observations that high-frequency stimulation of the affected neurons induces functional inhibition in target regions of the brain. DBS thus simulates the effect of an ablative surgical lesion but, unlike lessoning surgery, DBS adjusts the implanted electrode can be re-positioned (or removed). The mechanism of action remains unknown. Possible mechanisms include release of local inhibitory neurotransmitters, depolarization blockade, or jamming of abnormal neuron firing patterns. The device currently used for DBS is the Active system developed by Medtronic, Inc. (Minneapolis, MN). The system consists of several implantable and nonimplantable components (listed below), including a quadripolar electrode (four contact sites arranged along the distal edge) which is stereotactically implanted into the targeted structure. Stimulation parameters, including electrode contact site selection, stimulation pulse amplitude, frequency, and width adjusts to optimize symptom relief. Proprietary information of UnitedHealthcare. Copyright 2015 United HealthCare Services, Inc. Page 2
Reimbursement Guidelines Medicare will cover unilateral or bilateral thalamic ventralis intermedius nucleus (VIM) deep brain stimulation (DBS) for the treatment of essential tremor (ET) and/or Parkinsonian tremor and unilateral or bilateral subthalamic nucleus (STN) or globus pallidus interna (GPi) DBS for the treatment of Parkinson's disease (PD) only under the following conditions: Medicare will only consider DBS devices to be reasonable and necessary if they are Food and Drug Administration (FDA) approved devices for DBS or devices used in accordance with FDA approved protocols governing Category B Investigational Device Exemption (IDE) DBS clinical trials. For thalamic VIM DBS to be considered reasonable and necessary, patients must meet all of the following criteria: a. Diagnosis of ET based on postural or kinetic tremors of hand(s) without other neurologic signs, or diagnosis of idiopathic PD (presence of at least 2 cardinal PD features (tremor, rigidity, or bradykinesia)) which is of a tremor-dominant form b. Marked disabling tremor of at least level three or four on the Fahn-Tolosa-Marin Clinical Tremor Rating Scale (or equivalent scale) in the extremity intended for treatment, causing significant limitation in daily activities despite optimal medical therapy c. Willingness and ability to cooperate during conscious operative procedure, as well as during post-surgical evaluations, adjustments of medications and stimulator settings For STN or GPi DBS to be considered reasonable and necessary, patients must meet all of the following criteria: a. Diagnosis of PD based on the presence of at least two cardinal PD features (tremor, rigidity, or bradykinesia) b. Advanced idiopathic PD as determined by the use of Hoehn and Yahr stage or Unified Parkinson's Disease Rating Scale (UPDRS) part III motor subscale c. L-dopa responsive with clearly defined "on" periods d. Persistent disabling Parkinson's symptoms or drug side effects (e.g., dyskinesias, motor fluctuations, or disabling "off" periods) despite optimal medical therapy e. Willingness and ability to cooperate during conscious operative procedure, as well as during post-surgical evaluations, adjustments of medications and stimulator settings DBS is not reasonable and necessary and is not covered for ET or PD patients with any of the following: a. Non-idiopathic Parkinson's disease or "Parkinson's Plus" syndromes b. Cognitive impairment, dementia, or depression, which worsens or interferes with the patient's ability to benefit from DBS c. Current psychosis, alcohol abuse or other drug abuse. d. Structural lesions such as basal ganglionic stroke, tumor, or vascular malformation as etiology of the movement disorder e. Previous movement disorder surgery within the affected basal ganglion f. Significant medical, surgical, neurologic or orthopedic co-morbidities contraindicating DBS surgery or stimulation Patients who undergo DBS implantation should not be exposed to diathermy (deep heat treatment including shortwave diathermy, microwave diathermy and ultrasound diathermy) or any type of MRI, which may adversely affect the DBS system or adversely affect the brain around the implanted electrodes. DBS should be performed with extreme caution in patients with cardiac pacemakers or other electronically controlled implants, which may adversely affect or be affected by the DBS system. For DBS lead implantation to be considered reasonable and necessary, providers and facilities must meet all of the following criteria: Neurosurgeons must: o Be properly trained in the procedure; o Have experience with the surgical management of movement disorders, including DBS therapy; and Proprietary information of UnitedHealthcare. Copyright 2015 United HealthCare Services, Inc. Page 3
o Have experience performing stereotactic neurosurgical procedures. Operative teams must have training and experience with DBS systems, including knowledge of anatomical and neurophysiological characteristics for localizing the targeted nucleus, surgical and/or implantation techniques for the DBS system, and operational and functional characteristics of the device. Physicians specializing in movement disorders must be involved in both patient selection and postprocedure care. Hospital medical centers must have: o Brain imaging equipment (MRI and/or CT) for pre-operative stereotactic localization and targeting of the surgical site(s); o Operating rooms with all necessary equipment for stereotactic surgery; and o Support services necessary for care of patients undergoing this procedure and any potential complications arising intraoperatively or postoperatively. CPT/HCPCS Codes Code Description 61863 Twist drill, burr hole, craniotomy, or craniectomy with stereotactic implantation of neurostimulator electrode array in subcortical site (e.g., thalamus, globus pallidus, subthalamic nucleus, periventricular, periaqueductal gray), without use of intraoperative microelectrode recording; first array 61864 Twist drill, burr hole, craniotomy, or craniectomy with stereotactic implantation of nucleus, periventricular, periaqueductal gray), without use of intraoperative microelectrode recording; each additional array (List separately in addition to primary procedure) 61867 Twist drill, burr hole, craniotomy, or craniectomy with stereotactic implantation of nucleus, periventricular, periaqueductal gray), with use of intraoperative microelectrode recording; first array 61868 Twist drill, burr hole, craniotomy, or craniectomy with stereotactic implantation of nucleus, periventricular, periaqueductal gray), with use of intraoperative microelectrode recording; each additional array (List separately in addition to primary procedure) 61880 Revision or removal of intracranial neurostimulator electrodes 61885 Insertion or replacement of cranial neurostimulator pulse generator or receiver, direct or inductive coupling; with connection to a single electrode array 61886 Insertion or replacement of cranial neurostimulator pulse generator or receiver, direct or inductive coupling; with connection to 2 or more electrode arrays 61888 Twist drill, burr hole, craniotomy, or craniectomy with stereotactic implantation of nucleus, periventricular, periaqueductal gray), with use of intraoperative microelectrode recording; each additional array (List separately in addition to primary procedure) 95961 Functional cortical and subcortical mapping by stimulation and/or recording of electrodes on brain surface, or of depth electrodes, to provoke seizures or identify vital brain structures; initial hour of attendance by a physician or other qualified health care professional 95962 Functional cortical and subcortical mapping by stimulation and/or recording of electrodes on brain surface, or of depth electrodes, to provoke seizures or identify vital brain structures; each additional hour of attendance by a physician or other qualified health care professional (List separately in addition to code for primary procedure) Proprietary information of UnitedHealthcare. Copyright 2015 United HealthCare Services, Inc. Page 4
95970 Electronic analysis of implanted neurostimulator pulse generator system (eg, rate, pulse output modulation, cycling, impedance and patient compliance measurements); simple or complex brain, spinal cord, or peripheral (i.e., cranial nerve, peripheral nerve, sacral nerve, neuromuscular) neurostimulator pulse generator/transmitter, without reprogramming 95971 Electronic analysis of implanted neurostimulator pulse generator system (eg, rate, pulse output modulation, cycling, impedance and patient compliance measurements); simple spinal cord, or peripheral (i.e., peripheral nerve, sacral nerve, neuromuscular) neurostimulator pulse generator/transmitter, with intraoperative or subsequent programming 95972 Electronic analysis of implanted neurostimulator pulse generator system (eg, rate, pulse output modulation, cycling, impedance and patient compliance measurements); complex spinal cord, or peripheral (i.e., peripheral nerve, sacral nerve, neuromuscular) (except cranial nerve) neurostimulator pulse generator/transmitter, with intraoperative or subsequent programming, first hour 95973 Electronic analysis of implanted neurostimulator pulse generator system (eg, rate, pulse output modulation, cycling, impedance and patient compliance measurements); complex spinal cord, or peripheral (i.e., peripheral nerve, sacral nerve, neuromuscular) (except cranial nerve) neurostimulator pulse generator/transmitter, with intraoperative or subsequent programming, each additional 30 minutes after first hour (List separately in addition to code for primary procedure) 95978 Electronic analysis of implanted neurostimulator pulse generator system (eg, rate, pulse amplitude and duration, battery status, electrode selectability and polarity, impedance and patient compliance measurements), complex deep brain neurostimulator pulse generator/transmitter, with initial or subsequent programming; first hour 95979 Electronic analysis of implanted neurostimulator pulse generator system (eg, rate, pulse amplitude and duration, battery status, electrode selectability and polarity, impedance and patient compliance measurements), complex deep brain neurostimulator pulse generator/transmitter, with initial or subsequent programming; each additional 30 minutes after first hour (List separately in addition to code for primary procedure L8681 Patient programmer (external) for use with implantable programmable neurostimulator pulse generator, replacement only L8685 Implantable neurostimulator pulse generator, single array, rechargeable, includes extension L8686 Implantable neurostimulator pulse generator, single array, nonrechargeable, includes extension L8687 Implantable neurostimulator pulse generator, dual array, rechargeable, includes extension L8688 Implantable neurostimulator pulse generator, dual array, nonrechargeable, includes extension L8679 Implantable Neurostimulator, Pulse Generator, Any Type (new code effective 01/01/2014) (Replaces HCPCS codes L8685, L8686, L8687, and L8688) ICP/PCS Codes ICP Code Description PCS Code Description 02.93 Implantation or replacement of intracranial neurostimulator lead(s) 00H00MZ Brain, Open Proprietary information of UnitedHealthcare. Copyright 2015 United HealthCare Services, Inc. Page 5
00H03MZ 00H04MZ 00H60MZ 00H63MZ 00H64MZ 00HE0MZ 00HE3MZ 00HE4MZ 00P00MZ 00P03MZ 00P04MZ 00P60MZ 00P63MZ 00P64MZ 00PE0MZ 00PE3MZ 00PE4MZ 00PEXMZ 00H03MZ Brain, Percutaneous Brain, Percutaneous Endoscopic Cerebral Ventricle, Open Endoscopic Cranial Nerve, Open Cranial Nerve, Percutaneous Cranial Nerve, Percutaneous Endoscopic Brain, Open Brain, Percutaneous Brain, Percutaneous Endoscopic Cerebral Ventricle, Open Endoscopic Cranial Nerve, Open Cranial Nerve, Percutaneous Cranial Nerve, Percutaneous Endoscopic Cranial Nerve, External Brain, Percutaneous Proprietary information of UnitedHealthcare. Copyright 2015 United HealthCare Services, Inc. Page 6
References Included (but not limited to): CMS NCD(s) NCD 160.24 Parkinson s Disease Reference NCDs: NCD 160.18 Vagus Nerve Stimulation NCD 160.7 Electrical Nerve Stimulators CMS Article One article CMS Benefit Policy Manual Chapter 14; 10 Coverage of Medical Devices Chapter 15; 260 Ambulatory Surgical Center Services CMS Claims Processing Manual Chapter 12; 90.3 Physicians Services Performed in Ambulatory Surgical Centers (ASC) Chapter 14; 10 General ASC Information Chapter 20; 110 General Billing Requirements - for DME, Prosthetics, Orthotic Devices, and Supplies Chapter 32; 50 Parkinson's Disease MLN Matters Calendar Year (CY) 2014 Update for Durable Medical Equipment, Prosthetics, Orthotics, and Supplies, MM8531, January 01, 2014 UnitedHealthcare Medicare Advantage Coverage Summaries Parkinson s Disease UnitedHealthcare Reimbursement Policies NCD 160.18 Vagus Nerve Stimulation UnitedHealthcare Medical Policies Deep Brain Stimulation Others Decision Memo for Deep Brain Stimulation for Parkinson's Disease, CMS Website Technology Assessment: Bilateral Deep Brain Stimulation (DBS) Of The Subthalamic Nucleus (STN) Or The Globus Pallidus Interna (Gpi) For Treatment Of Advanced Parkinson's Disease, CMS Website History Date Revisions 06/10/2015 Annual Review for MRP Committee presentation and approval 05/28/2014 Annual Review for MRP Committee presentation and approval 05/08/2013 Removed some of the current criteria (ICPs, HCPCS codes L8685-L8688) Added ICP 01.20 Kept CPT Codes 61863-61868 05/07/2013 Removed CPT/HCPCS Codes: E0752-Implantable neurostimulator electrode, each (Expired 01/01/2006) E0756-Implantable neurostimulator pulse generator (Expired 01/01/2006) 61862-Twist drill, burr hole, craniotomy, or craniectomy for stereotactic implantation of one neurostimulator array in subcortical site (e.g., thalamus, globus pallidus, subthalamic nucleus, periventricular, periaqueductal gray) (Expired 01/01/2004) 11/30/2011 No change Proprietary information of UnitedHealthcare. Copyright 2015 United HealthCare Services, Inc. Page 7