User guide. MD PBX Light MD MD PBX Light AV MD PBX Light ES MD PBX Light BG



Similar documents
Manufactures of: All. Dallas Delta Corporation Pty.Ltd. Pty.Ltd. 102 Albert St. East Brunswick, 3057 Vic. Tel: Fax:

System Manual 1+n technology Issue 2013

Operating Instructions. Telephone System tiptel 1/8 fax clip tiptel 2/8 clip. (Release 2) tiptel

Dialog 4220 Lite/Dialog 4222 Office

ADA COMPLIANT BOX STYLE TELEPHONE INSTALLATION, PROGRAMMING AND OPERATING INSTRUCTIONS FOR MODEL PBX

PagePac PAGEPAL V

System Manual 1+n technology

Euroset Connections

Automatic Telephone Dialer TD-101(W)

AUTODIALLER / QUICKDIALLER - SA132

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q R0001

KCIEN KCIENSBP. Heavy Duty Stainless Steel Illuminated Keypads INSTALLATION MANUAL. Range: DIGICODE (Stand-Alone Keypad)

Configuring the 930A for Common PBX Metallic Signaling Interfaces

Art.275 PABX Interface

TELEPHONES Accessories. Phones. parts. Keypad Telephones Auto Dial. Courtesy Inmate Telephones. Hands-Free Telephone. Catalog.

FältCom ECII Flex Manual. Version: C Updated: Manual FältCom ECII Flex Page 1 of 42

PBX System. Installation Manual AS 200 IT

AASTRA 9110 User Guide

FWT-8848 GSM (GATEWAY) USER S MANUAL

TS-770 SERIES CONFERENCE SYSTEM

CelluLine CGW-TS GSM Cellular Gateway. Installation and Programming Manual

Analog Door Phone Model LUADS MAT Code #

2013 Wireless Video Intercom INSTALLATION GUIDE

Innkeeper PBX. Desktop Digital Hybrid. User Guide. JK Audio

ALCATEL 2315 USER GUIDE

Innovative DOOR STATION Solutions

PBXport. Rackmount PBX Digital Hybrid. User Guide. JK Audio

Shutter Actuator Standard, 4-fold, 230 VAC, MDRC RA/S , GH Q R0111. ABB i-bus EIB

Power Supply and Indicator Unit Type Fig. 1 Type Mounting and Operating Instructions EB 9539 EN

(68.52) X. June 2000 Supercedes February xenex CONVENTIONAL FIRE DETECTION & ALARM SYSTEM. we business differently

Memcom Emergency Telephone

HiPath HiPath 1120 HiPath 1130 HiPath 1150 HiPath Instruction Manual System Telephone Profiset 3030

Model PBX 308 Plus. Extension User Guide

COLOR VIDEO DOOR PHONE CDV-71BE/D

MILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS)

PS 29M DUAL CHANNEL BELTPACK IN METAL CASE

BIBUS VOP. large blocks of flats with switchboard and mixed mainly audio systems. Ideal for door phone systems with up to 250 users.

Door Phone VoIP. User manual IPDPS 01C IPDPS 02C IPDPS 01 IPDPS 02

Installation & Operation Manual for EC-8 Phone Line Consolidator

TOA INTERCOM SYSTEM. TOA Corporation OPERATING INSTRUCTIONS

2 WIRE video door entry system

Professional answering machine with time control, SMS service and message transfer. Retell 540 office

AT&T. PARTNER Plus Door Phone. Installation and Operation Manual

Technical Note. TN: Technical note for phone access of HMS system. Rev. a

V-2901 UNIVERSAL DOOR ANSWERING SYSTEM

How To Use A Ppanasonic Cell Phone With A Cell Phone From A Cellphone From Alexa (Panasonic) For A Long Distance Phone From An Older Model (Panoramos) For An Extra Money (Panamontani

SV 210 Signal Splitter and Incremental Converter for Sine-Cosine Encoders

3 Specification. Master Chip Broadcom Keys Direct-button 1. Microphone 1. Amplifier 0.5W Speaker 0.5W. Voice

Speech Dialler Engineering Information

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start * see variants. Applications.

500r+ Installation and User Guide

WITURA CORPORATION SDN BHD

innkeeper PBX Desktop Digital Hybrid User Guide JK Audio Warranty

15 Series - Electronic step relay and dimmer. Features SERIE

GDI User and programming manual V 2.0

NOKIA 32 SUPPORT GUIDE FOR INSTALLING NOKIA 32

F(t) Forssell Technologies Inc

VOCALISER USER INSTRUCTIONS. Pyronix Ltd OCTOBER RINS113 Issue 2

Preset Counter signo 721

1 All safety instructions, warnings and operating instructions must be read first.

RY2 miniature industrial relays

MICROSENS. Central 48 V DC Power Supplies for PoE-Components. Description. Features

Technical data. General specifications. Signal voltage V DC Signal duration. 1 s Input 2. Signal voltage. 1 s Analog output.

PSU-U-24V/AC-6A/10/FTA-TR-MC PSAC 0624

ZMR 80 STEREO MODULAR ZONER USERS MANUAL

Technical data. General specifications. Indicators/operating means. Electrical specifications Operating voltage U B Power consumption P 0 Interface

accessories and TechnoloGy Behnke electronics sip view inside a Behnke sip intercom Technology

Modular I/O System Analog and Digital Interface Modules

USER MANUAL MANUAL AH99-PN.

GSM Door Phone System

innkeeper PBX Desktop Digital Hybrid User Guide JK Audio

innkeeper PBX Desktop Digital Hybrid User Guide JK Audio Warranty

Link SIP Door Phone. Manual V1.0. Linkcom France rue du Soleil Levant CLAMART Copyright 2008 Linkcom Tous droit réservés

OM2260VW2 USER MANUAL VERIZON WIRELESS HOME PHONE CONNECT

Mini-PBX Telephone Switching System User and Installation Guide

Multifunction devices

2.4 GHz Dual Handset Cordless Telephone Answering System 2255 with Caller ID/Call Waiting

TELEPHONE LINE ANALYZER KIT

AA9604 Auto Attendant

Quick Reference Guide

AC-115 Compact Networked Single Door Controller. Installation and User Manual

System Administration Guide. Model KS 832. Expandable up to 1664

DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

Firmware version: 1.10 Issue: 7 AUTODIALER GD30.2. Instruction Manual


USER MANUAL. KIT VIDEO DOOR PHONE 2 smart 1 family

Model PBX 416+ Programming & User Guide

CSP Combined Series. Telephone Door Entry. with. Proximity Keyfob Access

Universal Host. Desktop Digital Hybrid. User Guide. JK Audio

Meridian 8314 Business Terminal User Guide

Personal Speed Dial Numbers

User guide The Konftel 200W conference phone

Name Description Model Number. Parameters Min. Typ. Max. Note. Vaux Voltage 9.8 V 12 V 13.2 V Auxiliary Supply Voltage

Installation Guide. DEVIreg 530. Electronic Thermostat.

Stove Guard Kit User Manual

Features, Benefits, and Operation

COMPALARM AP GENERAL MAIN FEATURES

TLK 48 MICROPROCESSOR-BASED DIGITAL ELECTRONIC REGULATOR

Transcription:

User guide MD PBX Light MD MD PBX Light AV MD PBX Light ES MD PBX Light BG Doorstation with telephone line interface for the connection to telephone systems Version with 1 bell button Page 1

Contents Description...3 Features...4 Connection diagram...5 View of the MD PBX Light electronic board...6 Installation...6 Telephone number programmation...8 How to use...9 Technical data... 11 Page 2

Description The doorstation with telephone line interface MD PBX Light can be connected to standard analogue T/R extension lines of any PABX. The unit is delivered in four different versions: the BG version for installation behind existing panels, the MD version with a designer aluminium case, the AV version with a vandal proofed aluminum panel and the ES version with a stainless steel casing. All versions can have up to one bell chime button. The connection of the doorstation to the telephone switch is done using two wires. Further a 12 Vac power supply is needed for the door opener and the illumination lamp in the doorstation. For this another two wires are necessary. We suggest in any case to provide an illumination of the doorstation as the lamps heat will ensure that the condensing water formation and a too low operating temperature can be prevented. Please take care that in some extrem enviroment situations the unit might need an add on heating element. The device is deliverd with microphone and loudspeaker. The volume of the loudspeaker and the microphone can be regulated. The unit is activated using a bell button. Herefore a galvanic, powerless contact is needed. Please take care that the activation LED will be lit only when the device is busy. After the closing of the button contact the device will size the line, the red LED will be lit, and the programmed telephone number is dialed using the selected mode: rotary dial or DTMF. The telephone numer is programmed using the four jumpers groups J7 to J10. A one to four digits long telephone number can be programmed. With the jumper group J7 the frist dialed digit is programmed, with the group J10 the last one. If no jumpers are set in a group, no digit will be dialed for that position. The single digits are programmes using a BCD code. The digits 0 to 9 and the special DTMF code *,#,A,B,C can be programmed. If needed the MD PBX Light doorstation with telephone line interface can also be called. As soon as the first call signal is recognized the unit will answer the call. In this case the device will work in the same way as if somebody had activated the bell button. The dialled DTMF number is used as acknowledgment tone that a connection to the doorstation is active. We suggest that also if only a calling function has to be provided (i.e. if normal chime bells are used instead to dial an extension), a number is programmed in any case, to ensure the described feature. The automatic call answer function can be deactivated by cutting the R15 resistance on the device board. During the connection using a DTMF dial pad telephone a door opener contact Page 3

can be activated dialing the "7". The door opener contact is activated as long as the MD PBX Light detects the DTMF signal. If only one burst is detected the door opener will be activated for 4 seconds. The connection will be terminated as soon as a busy tone is surley detected. The MD PBX Light can be released also dialing the DTMF digit "3" during the connection. If the called party doesn't answer the unit will drop the connection after 7 ringback tones. For the enhanced security the unit has also a hardware timer. This will ensure that the connection is terminated in any case after the time out. The time out can be set to 1, 2 or 4 minutes using jumper which can be find inside the unit. Features - 1 to 4 digit long number dial - High quality handsfree speach controlled unit - Tone detection - Automatic call answer - Volume regulation for loudspeaker and microphone - With DTMF dial controlled door opener contact - Connection to any PABX T/R analogue extension line - DTMF or rotary dial selectable - Programmable time out timer Page 4

Connection diagram Page 5

View of the MD PBX Light electronic board Volume loudspeaker Volume microphone Microphone connector Loudspeaker connector Door opener contact Bell button Analogue telephone line Line size LED Rotary dial/dtmf selection 1 2 4 Telephone number programming Hardware timer selection 1,2, 4 minutes Installation Depending on the delivered version install the MD PBX Light doorstation as required. With flush mounting versions the front plate and the installed electronic board should be take off during the installation operations of the box. For the MD Version also for the wall mounting version the front plate and the installed electronic board should be dismounted for the installing operations. With the AV and ES version you can separate the complete unit with front panel, back box and electronic board from the wall mounting case. In this case you don't need to dismount the electronic board. With the AV verion with flush mounting installation do not forget to apply the delivered fitting strip to the front panel. Page 6

With the BG version for installation behind existing panels install the electronic board in his case or letter box. Please take care that a too large distance between board and microphone can reduce the voice quality of the unit. The bell button contact has to be connected powerless. With the installation of the loadspeaker and the microphone please take care that enough acoustic separation between the two item is granted. Especially the backward generated sound waves from the loadspeaker should not get outside the case or reach the microphone. If the delivered installation holders for microphone and loadspeaker are used, this should not be a problem. If possible use different cables to connect the telephone line and the AC power supply for the lamp and door opener. This will reduce the possibility to have "humming" noises on the connection. After the installation and cabling using the in this documentation provided connection diagram, the number to be dialled has to be programmed. This is done by setting the appropiate jumpers. The dialed number can be 1 to 4 digit long. The jumper setting can be saw on the following table. The first digit is defined by the first group of four jumpers. The number is programmed using a BCD hex code, where the lowest digit (2 ) is the first jumper on the right of each group of four. The number "0" is set as the hex code "A" (decimal 10). Digit which are not used are to be set empty (no jumpers). After the programmation of the telephone number you should select the appropiate dial mode for your PABX (default is DTMF). The unit is now ready to work. You should set up a connection with the door unit. A regulation of the sending and receiving volume may be necessary. To do this you should use the regulators placed on the MD PBX Light doorstation. Please take care to regulate VERY carefully. If this is done by two people this might be helpful. If the loudspeaker send only "broken" tones, or it has a too low volume, changing the volume of the microphone on the MD PBX Light may help. With a very loud external enviroment the unit may be have difficulties detecting the busy tone. This may happen also with tone which are not within the values as indicated in the technical specification at the end of this document. In this case you should use always the dial of the digit "3" to terminate the connection. Please note that only one door opener with 40 Vpp and 2 A can be connected to the unit. If you need to drive more door openers or if you need an higher voltage or current you should use a relais. We suggest the use of the ACI Farfisa relais 1471. Page 7

Furthermore please consider this for the installation: - If you are using digital sets or featurphones on your PABX please take care that these are enabled to send DTMF tones also after an incoming call. You need this to open the door. Telephone number programmation J7 (X000) J8 (0X00) J9 (00X0) J10 (000X) 1 X X X X 2 X X X X 3 X X X X X X X X 4 X X X X 5 X X X X X X X X 6 X X X X X X X X 7 X X X X X X X X X X X X 8 X X X X 9 X X X X X X X X 0 X X X X X X X X * X X X X X X X X X X X X # X X X X X X X X A X X X X X X X X X X X X B X X X X X X X X X X X X C X X X X X X X X X X X X X X X X Page 8

How to use Call from outside - The visitor presses the bell button - The line is sized and the programmed number is dialed - The extension is called - On the doorspeaker the visitor can hear a ringback tone - If you are busy or you can't answer within seven calls the line will be automaticaly dropped - As soon as you answers the call you can talk to the visitor at the door - At the end of the conversation press the key 7 to open the door. The opener will be activated for 4 seconds. If you need more time press more times the key 7. To terminate the call press the key 3. OR - Press the key 3 to terminate the call without opening the door - Hang up the handset Page 9

Call from inside - You want to call the doorstation without a call being set from outside - Lift the handset and dial the telephone number of the doorstation - The doorstation is called and will answer the call automaticaly - The doorspeaker is activated and you can talk to the visitor - At the end of the conversation press the key 7 to open the door. The opener will be activated for 4 seconds. If you need more time press more times the key 7. To terminate the call press the key 3. OR - Press the key 3 to terminate the call without opening the door - Hang up the handset Page 10

Technical data Power supply Telephone line voltage Voltage insertion drop on T/R Current consumption Telephone line impedance Dial mode Rotary dial DTMF dial Tone recognition from telephone line min. 24 Vdc, max. 60 Vdc 10 V +/- 5% at 25 ma off hook: min. 18 ma stand-by: 2 µa 600 Ohm rotary dial, DTMF selectable impulse frequency: 10 Hz dial pause: 820 ms impulse duration: 60 ms impulse pause: 40 ms open line resistance: > 300 KOhm standard DTMF Tone duration: 70 ms Tone pause: 70 ms detectable tone frequency: 390 to 480 Hz detectable ringback tone: tone duration from 770 to 1100 ms. Release after 7/8 tones detectable long busy tone: tone duration from 170 to 550 ms. Release after 5/6 tones detectable short busy tone: tone duration from 70 to 150 ms. Release after 10/11 tones Door opener DTMF digit "7" Min. detectable DTMF tone duration: 45 to 50 ms Max. contact load: 40 Vpp, 2 A Closure duration: 4,5 seconds (or as long as a DTMF 7 digit is detected) Time out 1, 2 or 4 minutes selectable Enviromental themperature 0 to 45 C EMC EN 60555-2 EN 55022 EN 50082-1 Security EN 60950 Dimensions MD PBX Light MD Frontplate: 124 x 213 x 19 Installation box: 124 x 213 x 55 Wall mounting case: 151 x 232 x 80 MD PBX Light AV Frontplate: 100 x 247 x 4 Installation box: 90 x 236 x 55 Wall mounting case: 105 x 257 x 62 MD PBX Light ES Frontplate: 123 x 215 x 14 Installation box: 115 x 207 x 45 Wall mounting case: 142 x 232 x 90 MD PBX Light BG Electronic board: 82 x 150 x 25 Loudspeaker holder: 75 x 75 x 28 Page 11

2002 ROCOM GmbH. Product may change without notice. We do not respond for any errors or mistake in the present documentation. Printed in Germany. Your dealer: Made by: Energie- und Kommunikationssysteme GmbH Lessing Str. 20, 63110 Rodgau, Germany Tel. +49-6106-6600-0 Fax +49-6106-6600-66 E-Mail: rocom_gmbh@t-online.de www.rocom-gmbh.de Page 12