CONCEPTUALIZATION OF UTILIZING WATER SOURCE HEAT PUMPS WITH COOL STORAGE ROOFS



Similar documents
How Ground/Water Source Heat Pumps Work

Lesson 36 Selection Of Air Conditioning Systems

Carnegie Mellon University School of Architecture, Department of Mechanical Engineering Center for Building Performance and Diagnostics

Building Energy Systems. - HVAC: Heating, Distribution -

HOW TO CONDUCT ENERGY SAVINGS ANALYSIS IN A FACILITY VALUE ENGINEERING STUDY

Air-Conditioning Buying Guide

Integrated Solar Radiant Systems

HVAC Systems: Overview

Glossary of Heating, Ventilation and Air Conditioning Terms

Air Conditioning. The opportunity for energy efficiency. Low cost actions to reduce energy usage now

CONDENSATION IN REFRIDGERATED BUILDINGS

SIMULATION OF RADIANT COOLING PERFORMANCE WITH

A Roof Integrated Solar Heating System Without Storage

Climate and Energy Responsive Housing in Continental Climates. The Suitability of Passive Houses for Iran's Dry and Cold Climate. Farshad Nasrollahi

HEATING, VENTILATION & AIR CONDITIONING

AIR CONDITIONING EFFICIENCY F8 Energy eco-efficiency opportunities in Queensland Foundries

Creating Efficient HVAC Systems

CHAPTER 8 HVAC (Heating, Ventilation, and Air-Conditioning)

Renewable Heat Pumps. A guide for the technically minded

SPECIAL ISSUE: NATIONAL SCIENCE FOUNDATION WORKSHOP

HVAC Processes. Lecture 7

HEAT PUMP FREQUENTLY ASKED QUESTIONS HEAT PUMP OUTDOOR UNIT ICED-UP DURING COLD WEATHER:

Design Guide. Retrofitting Options For HVAC Systems In Live Performance Venues

Optimization of Water - Cooled Chiller Cooling Tower Combinations

Chilled Water HVAC Systems

Market Potential Study for Water Heater Demand Management

imagine SOLAR AIR CONDITIONING MADE EASY

SOLAR COOLING WITH ICE STORAGE

ENERGY SAVING STUDY IN A HOTEL HVAC SYSTEM

A NEW DESICCANT EVAPORATIVE COOLING CYCLE FOR SOLAR AIR CONDITIONING AND HOT WATER HEATING

HVACPowDen.xls An Easy-to-Use Tool for Recognizing Energy Efficient Buildings and HVAC Systems

Effects of Solar Photovoltaic Panels on Roof Heat Transfer

CHAPTER 9: WATER HEATING

FIRST RADIANT COOLED COMMERCIAL BUILDING IN INDIA CRITICAL ANALYSIS OF ENERGY, COMFORT AND COST

2 STEPS TO CONDUCTING YOUR HVAC ASSESSMENT

GEOTHERMAL HEATING AND COOLING INTRODUCTION

Preliminary Final Proposal

Federation of European Heating, Ventilation and Air-conditioning Associations

PTAC Selection Guide. Optimize your spend with the right PTAC equipment!

Heating & Cooling Efficiency

Drives and motors. A guide to using variable-speed drives and motors in retail environments

HVAC: Cool Thermal Storage

Measuring The Right Thing For Humidity Control It s the Dew Point Stupid!

COMPARATIVE LIFE-CYCLE ANALYSIS OF ENERGY-EFFICIENCY MEASURES AT TVA S CHATTANOOGA OFFICE COMPLEX: PHASE II RESULTS & FINAL DESIGN

newsletter engineers energy-saving strategies for Water-Source Heat Pump Systems volume 36 2 providing insights for today s hvac system designer

1. What percent of a commercial business s energy usage comes from their HVAC system? A. 13% B. 23% C. 33% D. 43% E. 53%

Typical Cooling Load Profile

Energy Efficiency in Industrial HVAC Systems

Heating / Ventilation / Air Conditioning Room Climate Control with ABB i-bus KNX

THERMAL STORAGE WITH ICE HARVESTING SYSTEMS

QUESTIONS TO ASK WHEN REPLACING YOUR HVAC TOGETHERWESAVE.COM

Condensing Boiler Efficiency

How To Use A Water Source Heat Pump

RESEARCH HIGHLIGHT. Performance Assessment of a Cold-Climate Air Source Heat Pump

EnergyPro Building Energy Analysis. Assisted Living Building

Ener.co & Viridian Energy & Env. Using Data Loggers to Improve Chilled Water Plant Efficiency. Randy Mead, C.E.M, CMVP

Heating, ventilation and air conditioning equipment. A guide to equipment eligible for Enhanced Capital Allowances

HEATING OF DOMESTIC OUTDOOR SWIMMING POOLS

Heating, ventilation and air conditioning (HVAC) equipment. A guide to equipment eligible for Enhanced Capital Allowances

In the compression-refrigeration loop (air conditioning), which is likely to be warmer? 1. Condenser coil 2. Evaporator coil

Energy Efficiency. Energy Efficient Home Cooling:

GEOTHERMAL HEAT PUMPS - TRENDS AND COMPARISONS - John W. Lund Geo-Heat Center

Why Daikin? 2015 Houston, Texas USA

Exploring the Building Energy Impacts of Green Roof Design Decisions - A Modeling Study of Buildings in 4 Distinct Climates

HEATING AND COOLING SYSTEMS THAT FIT COMFORTABLY WITHIN YOUR BUDGET.

Advanced Energy Design Guide LEED Strategies for Schools. and High Performance Buildings

How a Ground Source Heat Pump Works for a School or College

3/29/2012 INTRODUCTION HVAC BASICS

Federal Wage System Job Grading Standards for Air Conditioning Equipment Operating, Table of Contents

HVAC Simplified Approach Option

White Paper: Residential HVAC Split System Basics

Lawrence Berkeley National Laboratory Lawrence Berkeley National Laboratory

Vicot Solar Air Conditioning. V i c o t A i r C o n d i t i o n i n g C o., l t d Tel: Fax:

How To Control Humidity With A Humidifier

HVAC Technologies for Building Energy Efficiency Improvements 2013 National Symposium on Market Transformation. Richard Lord Carrier Fellow

ENERGY EFFICIENCY ENERGY EFFICIENCY: Saving Dollars While Clearing the Air

Hybrid (Dual Fuel) - Gas Heat and Air Source Heat Pump

KONRAD. Hybrid Fancoil Series

DAikin Altherma low temperature heat pump. end user leaflet

INSTALLATION AND OPERATION MANUAL

How to choose a heat pump and use it wisely

air conditioners how to choose a cooling system

Energy Efficiency Tips for Businesses

HVAC Basic Science - System Capacity

Circuit breaker panel. Power supply for condensing unit. Power supply for furnace. Air handler (Furnace)

Building HVAC Load Profiling Using EnergyPlus

Why is my air conditioner dripping on my customers?

Dehumidification Frequently Asked Questions

Comparing Energy Savings of Different VAV Systems

Ground Source Heat Pumps The Fundamentals. Southington, Connecticut John F. Sima III P.E.

1932 Lexington Houston, Texas (713) Recommendations for installation of cooling systems

How a Ground Source Heat Pump Works for Commercial Buildings

Green Building Handbook for South Africa Chapter: Heating, Ventilation and Cooling Luke Osburn CSIR Built Environment

A heat pump system with a latent heat storage utilizing seawater installed in an aquarium

Introduction. Motor Types

Chapter 3.4: HVAC & Refrigeration System

Transcription:

CONCEPTUALIZATION OF UTILIZING WATER SOURCE HEAT PUMPS WITH COOL STORAGE ROOFS by Dr. Bing Chen and Prof. John Bonsell Passive Solar Research Group University of Nebraska-Lincoln Omaha campus and Richard C. Bourne Davis Energy Group Davis, California ABSTRACT This is a concept paper which discusses the potential integration of a ground-coupled water source heat pump with the Cool Storage Roof (CSR) to provide full year thermal comfort at reduced energy costs. Prior CSR research efforts in Omaha, Nebraska and Davis, California have concentrated upon the physical phenomena related to maximizing summer radiative and evaporative heat loss from exposed CSR surfaces. Although performance results have been highly favorable, the CSR will not supply full building cooling demands for many applications. Coupling of the CSR with auxiliary cooling/heating systems may offer additional energy conservation opportunities. Combination with the groundcoupled heat pump may be particularly attractive for its utility load control features in addition to energy conservation advantages. In particular, the relatively constant ground source/sink condition can provide predictable daily peak cooling and heating output from the heat pump, allowing reduced heat pump sizing and potentially eliminating resistance auxiliary heating. This concept paper develops a preferred CSR-ground coupled heat pump schematic configuration, and evaluates both system advantages and probable sizing implications for a Midwest U.S. application. 1

1. INTRODUCTION The Cool Storage Roof concept has been under development both by the Davis Energy Group and (as the Nebraska Modif ied Roof Pond) by UNL's Passive Solar Research Group (PSRG) since 1982. The primary goal of prior DEG work has been CSR development for application as an improved commercial building roof system which extends roof life and reduces cooling loads. PSRG work has concentrated on evaluating both heating and cooling energy savings in the Nebraska climate. While previous papers consider the CSR as a passive, buildingintegrated energy conservation technology, potential also exists for a "hybrid" CSR which is integrated with the building HVAC system. In the hybrid or CSR "Type 211 configuration, water under the floating insulation layer may be cooled either by natural means or with an auxiliary chiller; and may also be used for heat storage in winter. The Type 2 CSR is lightly insulated between water and occupied space below to limit storage heat transfers, and to prevent summer condensation on the roof underside. Coupling the Type 2 CSR with a ground-coupled heat pump offers particularly attractive opportunities for both energy conservation and electric utility load control. Using the CSR as an "active" thermal storage reservoir when necessary allows off-peak electricity to be used for auxiliary cooling, eliminating or minimizing on-peak compressor operation. In winter, CSR storage potentially eliminates the need for auxiliary resistance heating in heat pump applications. This paper discusses one attractive approach to integrating CSR and ground-coupled heat pump technologies. 1.1 CSR DESCRIPTION CSR development has been discussed in earlier papers (see references (1), (2), (3) and (4)). Figure I shows the basic CSR configuration. A roof membrane is placed atop of the roof deck with rigid insulation panels floating a water layer over the membrane. For cooling, a pump distributes the storage water over the insulation panels at night. The water temperature drops as heat is radiated to the night sky and lost due to evaporation. During the winter, passive solar heat via direct gain or thermosiphon can can help satisfy heating loads.as shown in Figure 2. Extended CSR roof life is projected because the roof membrane is protected from the sun, wind, temperature extremes, drain clogging debris, and falling objects. Building cooling loads are reduced by pumping the water at night onto the floating panels, where it is cooled evaporation and night sky radiation before draining back through panel joints. The cool water remains below the panels in the daytine and may be used in several ways to provide full or partial building cooling. 2

In the most economical CSR configuration (called "Type 111) the roof membrane is not insulated from occupied space below, permitting direct building cooling through the roof deck. The Type 1 "Passive" CSR provides direct building cooling and its buildingcoupled thermal mass can reduce winter heating loads if properly controlled. However, the Type 1 CSR cannot be used to accomplish latent cooling ("dehumidification") because dripping water could cause interior damage if the ceiling surface were allowed to be colder than the indoor dew point temperature. This ' limitation will typically prevent mechanical chilling of the Type 1 CSR to shift auxiliary cooling loads off-peak, since this strategy would usually require water temperatures below the dew point. The Type 2 CSR provides insulation between CSR water and occupied space below to prevent ceiling condensation in extreme cooling conditions with CSR water mechanically chilled "off-peak". This configuration allows all cooling loads to be satisfied from the CSR and is ideal for climates where summer dehumidification is needed. The Type 2 CSR may be fully integrated into the building climate control system, as subsequently detailed. l.'2 THERMAL LOAD SHIFTING WITH HEAT PUMP - COOL STORAGE ROOFS Air and ground-coupled heat pumps have had limited market success in many areas of the country in competition with natural gas for space heating loads. Air-coupled heat pump efficiencies are penalized by the need for auxiliary resistance heating, which can generate unfavorable "morning spike" load patterns. Groundcoupled heat pumps offer higher efficiencies and need less auxiliary heat than air-coupled pumps, but are more expensive to install.' In heating climates, residential heat pumps sized for cooling are usually inadequately sized for heating, whether airor ground-coupled. Non-residential buildings offer improved heat pump markets in applications where building internal gains reduce heating loads. Coupling "downsized" heat pumps with thermal energy storage (TES) can reduce heat pump capacities, eliminate winter auxiliary heating requirements, and shift heat pump electrical energy consumption to off-peak periods. For non-residential applications, the Cool Storage Roof (CSR) presented offers a more promising TES/heat pump coupling because of the CSR's dual function and lower cost compared to packaged thermal storage components. The heat pump-coupled Type 2 CSR can benefit an electric utility in.two significant ways: 1. By Reducing Future Capac ity Requirements: Building cooling loads may be shifted fully or partially off-peak, depending on chiller sizing, water depth, cooling loads, and on-peak period length. 3

2. By Improving Annual Load Fadtors: Use of CSR for heating seasonal thermal storage offers off-peak savings to commercial building owners who normally heat with natural gas; the electric utility can realize increased winter revenues without increased peak capacity requirements. These significant utility benefits may only be realized if CSR economics are favorable for the building owner. While detailed "Type 2 CSR" value estimates have not been completed, excellent paybacks are anticipated for the following reasons: 1. Type 1 CSR's show less than two year paybacks due to extended roof life, cooling energy savings, extended HVAC equipment life, and electrical demand savings. 2. Conventional thermal energy storage (TES) systems show favorable paybacks in the U.S. without relative CSR advantages of free cooling in mild weather, cost reduction from combining TES and roof membrane & insulation functions and shorter piping runs, reduction of roof heat gains and losses, and TES space requirements. 4

2. THEORY OF OPERATION: HEAT PUMP-COUPLED CSR SYSTEM DESCRIPTION The Type 2 CSR to be evaluated in the proposed project will be integrated with a heat pump-based HVAC system as shown in Fig. 3. Three major components comprise the system, as shown. The CSR roofing system shown at the top of Fig. 3 includes the roof membrane, f loating roof insulation panels, piping and heads to distribute water onto the panels, and inlet/outlet connections to the CSR. The heat pump (upper dotted line) may be either air or ground coupled, although the latter offers superior efficiency. Refrigerant-to-water indoor heat exchange is provided, allowing.off-peak storage in the CSR of heat pump cooling and heating output, for subsequent use "on-peak". The fan coil (lower dotted line) provides hydronic heat exchange from both the heat pump and CSR to the building. The fan coil includes a centrifugal blower and two water-to-air heat exchange coils (Cl and C2). A microprocessor controller determines operating mode based on weather and system data. The heat pump-integrated Type 2 CSR system allows two stage heating and cooling from a combination of stored and direct heat pump output, and also allows the heat pump to provide either direct heating at the fan coil when the CSR is cool or direct cooling when the CSR is warm. As shown in Fig. 3, two pumps (Pl and P2), three motorized diverting valves (Vl, V2, and V3), and two check valves (CV) are required to provide the full range of desired system features. operating modes by season are as follows: 1. Summer: In normal weather, Pump P2 operates at night and directs CSR water through the'filter and valve V3 port B to be distributed and cooled above the floating insulation panels. When the indoor thermostat calls for cooling, pump P2 sends filtered water through valve V3 port A to the fan coil, from which it returns to the CSR through valve V2, either via port A (daytime, below panels) or Port B (night, for distribution above panels). When night cooling fails to drop the CSR to its programmed target, pump Pl and the heat pump are activated, with flow returning to the CSR via valve Vl port B, to mechanically chill the CSR during offpeak hours. When first stage cooling via coil Cl fails to satisfy the cooling load, the heat pump and Pump Pl are activated with flow directed in a closed loop from the heat exchanger through valve Vl port A into coil C2 (second stage cooling). See figure 3. 2. Winter: The heat pump is run continuously during off-peak hours to charge the CSR toward a precalculated temperature target, using pump Pl and valve Vl port B. Vi port A is activated to direct heat pump output to coil C2 upon offpeak heat demand by the building thermostat. The heat pump and direct coil C2 may also respond to winter afternoon cooling loads (as may develop in buildings with high internal gains) if the CSR is warm. During on-peak hours, space heating is provided by warm water stored in the CSR and circulated by pump P2 through coil Cl, returning through valve V2 port A to the CSR. See figure 3. 5

3. Spring and Fall: The CSR is maintained at a cool temperature using pump P2 and the upper roof return; the heat pump and pump Pl provide heating or additional cooling as needed via valve Vi port A and coil C2. 3. CONCLUSIONS Previous papers by the authors have discussed thermal performance results and full year performance simulations for direct coupled thermal storage roof applications without considering potential integration with auxiliary heating and cooling systems. Prior work suggests that substantial energy savings may be realized with the direct-coupled "Type 111 thermal storage roof applications. This paper presents a concept for integrating the Type 2 CSR (which is insulated from the space below) with the building HVAC system, to gain additional energy and electrical load control advantages. Funding is being solicited for modification of the University of Nebraskals, Energy Research Test Facility (located in Omaha) to test the proposed ground-coupled heat pump, Type 2 CSR concept. Research schedules favor Type 2 testing upon completion of Type 1 testing and ongoing CSR subsystem development work in 1991. 6

4. REFERENCES (1) Bourne, R. and B. Chen, "FULL YEAR PERFORMANCE SIMULATION OF A D:RECT-COOLED THERMAL STORAGE ROOF (DCTSR) IN THE MIDWEST", proceedings of the annual meeting of the American Solar Energy society, Denver, CO, June 1989. (2) Chen, B. and J. Kratochvil et. al., 11 MODELING OF THE RADIATIVE, CONVECTIVE AND EVAPORATIVE HEAT TRANSFER MECHANISMS OF THE NEBRASKA MODIFIED ROOF POND FOR THE DETERMINATION OF COOLING PERFORMANCE CURVES", Proceedings of the annual meeting of the American Solar Energy Society, MIT, Cambridge, MA, June, 1988. (3) Chen. B. et. al., "COOLING PERFORMANCE CURVE FOR THE NEBRASKA MODIFIED ROOF POND", Proceedings from the Combined 1987 Passive Solar Conference and Annual American Solar Energy Society Meeting, Portland, Oregon, August 1987. (4) Chen. B. et. al., "NEBRASKA MODIFIED ROOF POND: 1985 SUMMER PERFORMANCE RESULTS", Proceedings from the Combined 1986 Passive Solar Conference and Annual American Solar Energy Society Meeting, Denver, CO, June 1986. 7

8

9

10