UltraClean PCR Clean-Up Kit



Similar documents
UltraClean Forensic DNA Isolation Kit (Single Prep Format)

PowerFecal DNA Isolation Kit

UltraClean Soil DNA Isolation Kit

UltraClean Forensic DNA Isolation Kit (Single Prep Format)

TIANquick Mini Purification Kit

PCR and Sequencing Reaction Clean-Up Kit (Magnetic Bead System) 50 preps Product #60200

Genomic DNA Extraction Kit INSTRUCTION MANUAL

Wizard DNA Clean-Up System INSTRUCTIONS FOR USE OF PRODUCT A7280.

Genomic DNA Clean & Concentrator Catalog Nos. D4010 & D4011

How To Use An Enzymatics Spark Dna Sample Prep Kit For Ion Torrent

ZR DNA Sequencing Clean-up Kit

RNA PowerSoil Total RNA Isolation Kit Sample (Catalog No S) Information for Ordering Product Catalog No. Quantity Preps

50 g 650 L. *Average yields will vary depending upon a number of factors including type of phage, growth conditions used and developmental stage.

The fastest spin-column based procedure for purifying up to 10 mg of ultra-pure endotoxin-free transfection-grade plasmid DNA.

AxyPrep TM Mag PCR Clean-up Protocol

HighPure Maxi Plasmid Kit

Wizard SV Gel and PCR Clean-Up System

ZR-96 DNA Sequencing Clean-up Kit Catalog Nos. D4052 & D4053

ISOLATE II PCR and Gel Kit. Product Manual

ExpressArt Bacterial H-TR cdna synthesis kit. With extreme selectivity against rrnas

MagExtractor -Genome-

Plant Genomic DNA Extraction using CTAB

Classic Immunoprecipitation

How To Get Rid Of Small Dna Fragments

Contents. XI. Materials and Equipment Needed But Not Provided 5. DNA Extraction from Small Amount of Tissue 10

MinElute Handbook. Sample & Assay Technologies. March 2008

Aurora Forensic Sample Clean-up Protocol

NimbleGen DNA Methylation Microarrays and Services

AxyPrep Blood Genomic DNA Maxiprep Kit

VACUETTE RNAgard Blood Tubes BioMaxi Blood RNA Purification Kit. For the collection, preservation and purification of RNA from whole blood

GRS Plasmid Purification Kit Transfection Grade GK (2 MaxiPreps)

Application Guide... 2

Transformation Protocol

RNA Extraction and Quantification, Reverse Transcription, and Real-time PCR (q-pcr)

Kevin Bogart and Justen Andrews. Extraction of Total RNA from Drosophila. CGB Technical Report doi: /cgbtr

Maxwell 16 Blood DNA Purification System

Agencourt RNAdvance Blood Kit for Free Circulating DNA and mirna/rna Isolation from μL of Plasma and Serum

QIAGEN Supplementary Protocol

FOR REFERENCE PURPOSES

Southern Blot Analysis (from Baker lab, university of Florida)

TECHNICAL BULLETIN. HIS-Select Nickel Affinity Gel. Catalog Number P6611 Storage Temperature 2 8 C

Protocol v001 Page 1 of 1 AGENCOURT RNACLEAN XP IN VITRO PRODUCED RNA AND CDNA PURIFICATION

Blood Collection and Processing SOP

Automation in Genomics High-throughput purification of nucleic acids from biological samples. Valentina Gualdi Operational Scientist PGP

Genolution Pharmaceuticals, Inc. Life Science and Molecular Diagnostic Products

DNA SPOOLING 1 ISOLATION OF DNA FROM ONION

First Strand cdna Synthesis

Important Note. September 2011

RiboZol RNA Extraction Reagents

Chromatin Immunoprecipitation (ChIP)

ab Hi-Fi cdna Synthesis Kit

Inc. Wuhan. Quantity Pre-coated, ready to use 96-well strip plate 1 Plate sealer for 96 wells 4 Standard (liquid) 2

Arcturus PicoPure RNA Isolation Kit. User Guide

ProteoMiner Protein Enrichment Kits

Genomic DNA clean-up

An In-Gel Digestion Protocol

Recommended Procedures for the Extraction of RNA. Jan Pedersen USDA, APHIS, VS, National Veterinary Services Laboratories, Ames, IA 50010

MLX BCG Buccal Cell Genomic DNA Extraction Kit. Performance Characteristics

Dot Blot Analysis. Teacher s Guidebook. (Cat. # BE 502) think proteins! think G-Biosciences

Procedure for RNA isolation from human muscle or fat

User Manual. CelluLyser Lysis and cdna Synthesis Kit. Version 1.4 Oct 2012 From cells to cdna in one tube

LAB 11 PLASMID DNA MINIPREP

User s Manual. Bacteria Genomic DNA Kit. ExiPrepTM Bacteria Genomic DNA Kit K Version No.: 3.0 ( )

Pure-IP Western Blot Detection Kit

RevertAid Premium First Strand cdna Synthesis Kit

TransformAid Bacterial Transformation Kit

U.S. Patent No. 9,051,563 and other pending patents. Ver

Olympic B3 Summer Science Camp 2015 Weller, Smith, Putnam L3

Chromatin Immunoprecipitation

Frozen-EZ Yeast Transformation II Catalog No. T2001

RNeasy MinElute Cleanup Handbook

HiPer Ion Exchange Chromatography Teaching Kit

empcr Amplification Method Manual - Lib-A

DNA Analyst Training Laboratory Training Manual Protocol 2.02 Clean Technique

Archived. Gloves should be changed frequently during the analysis.

Troubleshooting Sequencing Data

Lab 10: Bacterial Transformation, part 2, DNA plasmid preps, Determining DNA Concentration and Purity

Detailed protocol: Combined method for RNA isolation. from cartilage

How To Make A Tri Reagent

ELUTION OF DNA FROM AGAROSE GELS

Sanger Sequencing: Sample Preparation Guide

HBV Quantitative Real Time PCR Kit

QIAamp DNA Mini and Blood Mini Handbook

Terra PCR Direct Polymerase Mix User Manual

One Shot TOP10 Competent Cells

Path-ID Multiplex One-Step RT-PCR Kit

RealStar HBV PCR Kit /2012

RT rxns. RT rxns TRANSCRIPTME Enzyme Mix (1) 40 µl 2 x 50 µl 5 x 40 µl

Agilent High Sensitivity DNA Kit Guide

Inverse PCR & Cycle Sequencing of P Element Insertions for STS Generation

HiPer Total RNA Extraction Teaching Kit

Genomic DNA Purification Student Laboratory Manual

GENOME RUSSIA PROJECT BLOOD SAMPLES COLLECTION, DNA EXTRACTION AND DNA QUALITY CONTROL PROTOCOLS

Register your instrument! MagSep Viral DNA/RNA Kit. Instructions for use

RealLine HCV PCR Qualitative - Uni-Format

Experiment 3: Extraction: Separation of an Acidic, a Basic and a Neutral Substance

Concert Plant RNA Reagent

Sanger Sequencing. Troubleshooting Guide. Failed sequence

PureZOL RNA Isolation Reagent Instruction Manual Catalog #

illustra puretaq Ready-To-Go PCR Beads

Transcription:

UltraClean PCR Clean-Up Kit Catalog No. Quantity 12500-50 50 Preps 12500-100 100 Preps 12500-250 250 Preps Instruction Manual Please recycle Version: 02212013 1

Table of Contents Introduction... 3 Protocol Overview... 3 Specifications... 3 Flow Chart... 4 Equipment Required... 5 Kit Contents & Storage... 5 Precautions & Warnings... 5 Protocols: Experienced User Protocol... 6 Detailed Protocol (Describes what is happening at each step)... 7 Vacuum Manifold Protocol... 9 Hints & Troubleshooting Guide... 11 Contact Information... 12 Products recommended for you..... 13 2

Introduction The UltraClean PCR Clean-Up Kit is designed to purify PCR products directly from a PCR or enzyme reaction in just 3 minutes without running an agarose gel. If you sequence your PCR reactions or have applications where efficient removal of PCR primers is critical, this kit is your solution. All reagents are optimized to remove primers, dntps and reaction components while purifying PCR reaction products in the size range of 60 bp to 10 kb. Protocol Overview With the addition of binding buffer, a novel silica spin filter is used to selectively bind the PCR or reaction product. Unwanted reaction components are passed through the filter by centrifugation. The desired product is then washed and recovered from the spin filter in certified DNA-free Tris buffer. The resulting DNA can be used for any downstream application. Specifications DNA Size range: 60 bp - 10 kb Binding capacity of Spin Filter: 20 g Final volume of DNA: 50 l Recovery rates: 80-100% High Throughput Options MO BIO offers a vacuum based protocol for faster processing without centrifugation for the DNA binding and column washing steps for Spin Filters. The MO BIO PowerVac Manifold allows for processing of up to 20 spin filter preps at a time using the PowerVac Mini Spin Filter Adapters. For additional high throughput options MO BIO offers the UltraClean -htp 96 Well PCR Clean-Up Kit for processing up to 2 x 96 samples using a centrifuge capable of spinning two 96 Well Blocks stacked (13 cm x 8 cm x 5.5 cm) at 2500 x g. For 96 well homogenization of soil, MO BIO offers the 96 Well Plate Shaker and Plate Adapter Set (MO BIO Catalog# 11996 & 11990, respectively.) This kit is for research purposes only. Not for diagnostic use. Other Related Products Catalog No. Quantity UltraClean -htp 96 Well PCR Clean-Up Kit 12596-4 12596-12 4 x 96 preps 12 x 96 preps UltraClean Agarose, Molecular Biology Grade 15003-50 15003-100 50 g 100 g UltraClean Lab Cleaner 12095-250 12095-500 12095-1000 250 ml bottle 500 ml bottle 1 L bottle PowerVac Manifold 11991 1 manifold PowerVac Mini System 11992 1 unit + 20 adapters PowerVac Mini Spin Filter Adapters 11992-10 11992-20 10 adapters 20 adapters 3

4

Equipment Required Microcentrifuge (10,000 x g) Pipettor (volumes required 50 l - 500 l) Vortex-Genie 2 Vortex (MO BIO Catalog# 13111-V or 13111-V-220) Reagents Required but not Included 100% ethanol (for the PowerVac Manifold protocol only) Kit Contents Kit Catalog # 12500-50 Kit Catalog # 12500-100 Kit Catalog # 12500-250 Component Catalog # Amount Catalog # Amount Catalog # Amount SpinBind 12500-50-1 28 ml 12500-100-1 55 ml 12500-250-1 144 ml SpinClean Buffer 12500-50-2 16.5 ml 12500-100-2 30 ml 12500-250-2 3 x 30 ml Elution Buffer 12500-50-3 3 ml 12500-100-3 6 ml 12500-250-3 15 ml Spin Filters 12500-50-SF 50 12500-100-SF 100 12500-250-SF 250 (Units in 2 ml Tubes) 2 ml Collection Tubes 12500-50-T 50 12500-100-T 100 12500-250-T 250 Kit Storage Kit reagents and components should be stored at room temperature (15-30 C). Precautions Please wear gloves when using this product. Avoid all skin contact with kit reagents. In case of contact, wash thoroughly with water. Do not ingest. See Material Safety Data Sheets for emergency procedures in case of accidental ingestion or contact. All MSDS information is available upon request (760-929- 9911) or at www.mobio.com. Reagents labeled flammable should be kept away from open flames and sparks. WARNING: SpinClean Buffer contains ethanol. It is flammable. Do not use bleach to clean the inside of the PowerVac Manifold or to rinse the PowerVac Mini Spin Filter Adapters when attached to the manifold. IMPORTANT NOTE FOR USE: Shake to mix the SpinBind before use. 5

Experienced User Protocol Please wear gloves at all times 1. Shake to mix the SpinBind before use. Add 5 volumes of SpinBind to your PCR reaction. Example: add 500 l to a 100 l PCR reaction. 2. Mix well by pipetting. If an oil overlay was used, you will now have two layers. The top layer is oil. 3. Transfer PCR/SpinBind mixture to a Spin Filter unit, while avoiding the transfer of oil. 4. Centrifuge 10-30 seconds at a minimum 10,000 x g (approximately 13,000 rpm) in a tabletop microcentrifuge. 5. Remove the Spin Filter basket and discard the liquid flow-through from the tube by decanting. 6. Replace the Spin Filter basket in the same tube. 7. Add 300 l SpinClean Buffer to the Spin Filter. 8. Centrifuge 10-30 seconds at a minimum 10,000 x g. 9. Remove Spin Filter basket and discard liquid flow through by decanting then replace basket back into the same tube. 10. Centrifuge 30-60 seconds at minimum 10,000 x g. 11. Transfer Spin Filter to a clean 2 ml Collection Tube (provided). 12. Add 50 l of Elution Buffer (10 mm Tris) solution provided or sterile water directly onto the center of the white Spin Filter membrane. The choice of using Tris or water at this point will not affect yield. DNA is more stable for storage in Tris. 13. Centrifuge 30-60 seconds at a minimum 10,000 x g. 14. Discard Spin Filter basket from the inside of the Spin Filter unit. Purified DNA is now in the 2 ml Collection Tube. The DNA will be free of all reaction components such as primers or linkers, enzyme, salt, and dntp s. Store DNA at -20 C. DNA is now ready to use. Thank you for choosing the UltraClean PCR Clean-Up Kit. 6

Detailed Protocol (Describes what is happening at each step) Please wear gloves at all times 1. Shake to mix the SpinBind before use. Add 5 volumes of SpinBind to the PCR reaction. Example: add 500 l to a 100 l PCR reaction. What s happening: SpinBind is a buffered salt solution. By mixing it with your PCR reaction product, you are creating a ph buffered high salt condition. ph is critical after the addition of SpinBind. ph above 8 results in low DNA recovery. ph below 5, results in primers co-purifying with your sample DNA. Optimal ph range is 6-7.5 for high recovery and total primer removal. 2. Mix well by pipetting. If an oil overlay was used, you will now have two layers. The top layer is oil. What s happening: Mixing well creates a homogeneous salt concentration throughout the sample tube. 3. Transfer PCR/SpinBind mixture to a Spin Filter unit, while avoiding the transfer of oil. What s happening: Although the oil does not affect DNA binding, it can be very messy if you do not remove it at this step. If you used a wax overlay, try to avoid carrying over any during this step. 4. Centrifuge 10-30 seconds at a minimum 10,000 x g (approximately 13,000 rpm) in a tabletop microcentrifuge. What s happening: DNA in the size range from 60 bp to 10 kb will bind to the white silica spin filter membrane at the bottom of the silica spin filter unit. The liquid that passes through the membrane will contain unwanted components of the PCR reaction such as: PCR primers, dntps, enzyme, and buffer constituents. The desired PCR product DNA will bind to silica under high salt conditions. 5. Remove the Spin Filter basket and discard the liquid flow-through from the tube by decanting. What s happening: This is flow through waste. This contains Guanidine HCl so be sure to check with your lab safety office for proper disposal and handling. 6. Replace the Spin Filter basket in the same tube. 7. Add 300 l SpinClean Buffer to the Spin Filter. What s happening: SpinClean is a wash solution. It will remove any traces of unwanted contaminants while allowing the desired PCR product DNA to stay bound to the silica spin filter membrane. SpinClean is an ethanol based wash solution. It contains less than 80% ethanol. This solution is flammable so use caution near flames. 8. Centrifuge 10-30 seconds at a minimum 10,000 x g. What s happening: As the SpinClean passes through the spin filter membrane, it cleans the PCR product DNA. 9. Remove Spin Filter basket and discard liquid flow through by decanting then replace basket back into the same tube. 7

10. Centrifuge 30-60 seconds at minimum 10,000 x g. What s happening: This step will remove any last traces of SpinClean. The ethanol in the SpinClean can have a negative affect on the DNA purity. 11. Transfer Spin Filter to a clean 2 ml Collection Tube (provided). 12. Add 50 l of Elution Buffer (10mM Tris) solution provided or sterile water directly onto the center of the white Spin Filter membrane. The choice of using Tris or water at this point will not affect yield. DNA is more stable for storage in Tris. What s happening: Placing the Elution Buffer in the center of the small white silica membrane will make sure the entire membrane is wetted. This will result in more efficient release of the desired DNA. 13. Centrifuge 30-60 seconds at a minimum 10,000 x g. What s happening: As the Elution Buffer passes through the silica membrane, DNA is released, and it flows through the membrane, and into the collection tube. The DNA is released because it can only bind to the silica spin filter membrane in the presence of salt. Elution Buffer is 10mM Tris ph. 8 and does not contain salt. 14. Remove Spin Filter basket from the 2 ml Collection Tube. Seal tube and store DNA at -20 C. What s happening: Purified DNA is now in the collection tube. The DNA is UltraClean and free of all reaction components such as primers or linkers, enzyme, salt, and dntp s. The DNA is now ready to use for any application. The DNA is in a 50 l volume. To concentrate it, see the Hints and Troubleshooting Guide. Thank you for choosing the UltraClean PCR Clean-Up Kit. 8

Vacuum Protocol using the PowerVac Manifold Please wear gloves at all times For each sample lysate, use one Spin Filter column. Keep the Spin Filter in the attached 2 ml Collection Tube and continue using the Collection Tube as a Spin Filter holder until needed for the Vacuum Manifold Protocol. Label each Collection Tube top and Spin Filter column to maintain sample identity. You will need to provide 100% ethanol for step 4 of this protocol 1. For each prep, attach one aluminum PowerVac Mini Spin Filter Adapter (MO BIO Catalog# 11992-10 or 11992-20) into the Luer-Lok fitting of one port in the manifold. Gently press a Spin Filter column into the PowerVac Mini Spin Filter Adapter until snugly in place. Ensure that all unused ports of the vacuum manifold are closed. Note: Aluminum PowerVac Mini Spin Filter Adapters are reusable. 2. Transfer up to 650 l of prepared sample lysate (from step 2) to the Spin Filter column. 3. Turn on the vacuum source and open the stopcock of the port. Hold the tube in place when opening the stopcock to keep the spin filter steady. Allow the lysate to pass through the Spin Filter column. After the lysate has passed through the column completely, if you have more sample, load again with the next 650 l until all of the lysate has been loaded onto the Spin Filter column. Close the oneway Luer-Lok stopcock of that port. Note: If Spin Filter columns are filtering slowly, close the ports to samples that have completed filtering to increase the pressure to the other columns. 4. Load 800 l of 100% ethanol into the Spin Filter so that it completely fills the column. Open the stopcock while holding the column steady. Allow the ethanol to pass through the column completely. Close the stopcock. 5. Add 300 l of SpinClean Buffer to each Spin Filter. Open the Luer-Lok stopcock and apply a vacuum until SpinClean Buffer has passed through the Spin Filter completely. Continue to pull a vacuum for another minute to dry the membrane. Close each port. 6. Turn off the vacuum source and open an unused port to vent the manifold. If all 20 ports are in use, break the vacuum at the source. Make certain that all vacuum pressure is released before performing the next step. It is important to turn off the vacuum at the source to prevent backflow into the columns. 7. Remove the Spin Filter column and place in the original labeled 2 ml Collection Tube. Place into the centrifuge and spin at 13,000 g for 1 minute to completely dry the membrane. 8. Transfer the Spin Filter column to a new 2 ml Collection Tube and add 50 l of Elution Buffer to the center of the white filter membrane. 9. Centrifuge at room temperature for 30 seconds at 10,000 x g. 9

10. Discard the Spin Filter column. The DNA in the tube is now ready for any downstream application. No further steps are required. We recommend storing DNA frozen (-20 to -80 C). Elution Buffer is 10 mm Tris and contains no EDTA. To concentrate the DNA see the Hints & Troubleshooting Guide. Thank you for choosing the UltraClean PCR Clean-Up Kit. 10

Hints and Troubleshooting Guide Concentrating the DNA Your final volume will be 50 l. If this is too dilute for your purposes, add 2 l of 5 M NaCl and mix. Then add 100 l of 100% cold ethanol. Mix. Centrifuge at 10,000 x g for 5 minutes. Decant all liquid. Dry residual ethanol in a speed vac or desiccator or ambient air. Resuspend precipitated DNA in desired volume. DNA Floats Out of Well When Loaded on a Gel Residual SpinClean in the final sample. Prevent this by being careful in step 11 not to transfer liquid onto the bottom of the spin filter basket. Ethanol precipitate to remove residues of SpinClean. (See procedure for Concentrating the DNA above.) Low Recovery Low recoveries can be due to not mixing SpinBind well with your sample in step 2. Incomplete removal of SpinClean can also reduce yields. Make sure your centrifuge is spinning at 10,000 x g minimum. Enzyme Reactions Inhibited If you chose to elute in a buffer containing EDTA, you may see inhibition of subsequent enzymatic reactions. Re-purify the sample with this kit and use the Tris solution Elution Buffer provided for the elution step. Cleaning of the PowerVac Mini Spin Filter Adapters It is recommended to rinse the PowerVac Mini Spin Filter Adapters promptly after use to avoid salt build up. To clean the PowerVac Mini Spin Filter Adapters, rinse each adapter with DI water followed by 70% ethanol and flush into the manifold base. Alternatively, remove the adapters and wash in laboratory detergent and DI water. PowerVac Mini Spin Filter Adapters may be autoclaved. Do not use bleach to clean the PowerVac Mini Spin Filter Adapters while attached to the PowerVac Manifold. Bleach should never be mixed with solutions containing guanidine and should not be used to clean the PowerVac Manifold. For more information on cleaning the PowerVac Manifold, please refer to the PowerVac Manifold manual. 11

Contact Information Technical Support: Phone MO BIO Laboratories, Inc. Toll Free 800-606-6246, or 760-929-9911 Email: technical@mobio.com Fax: 760-929-0109 Mail: MO BIO Laboratories, Inc, 2746 Loker Ave West, Carlsbad, CA 92010 Ordering Information: Direct: Phone MO BIO Laboratories, Inc. Toll Free 800-606-6246, or 760-929-9911 Email: orders@mobio.com Fax: 760-929-0109 Mail: MO BIO Laboratories, Inc, 2746 Loker Ave West, Carlsbad, CA 92010 For the distributor nearest you, visit our web site at www.mobio.com/distributors 12

Products recommended for you For a complete list of products available from MO BIO Laboratories, Inc., visit www.mobio.com Description Catalog No. Quantity 12596-4 4 x 96 preps UltraClean -htp 96 Well PCR Clean-Up Kit 12596-12 12 x 96 preps UltraClean GelSpin DNA Extraction Kit 12400-50 12400-100 12400-250 50 preps 100 preps 250 preps UltraClean 15 DNA Purification Kit 12100-300 300 preps PowerClean DNA Clean-Up Kit 12877-50 50 preps Dye Dots 15020-10 10 plates 15020-20 20 plates 13