centro ricerche-sviluppo Date received: 19-07-11 Date of issue: 06-09-11 VIA CA' LEOCIO, 2 Report consists of 6 test reports. Defects before testing: one Sample name: BEETLE 131179 Overall dimensions: 760 x 725 x 1030 (h) mm List performed tests 1. Seat and back static load test 1335-3:2009 AC:2009, clause 7.2.1-7.2.2 2. Seat and back durability - E 1335-3:2009 AC:2009 - Clause 7.3.1 3. Arm rests durability E 1335-3:2009 AC:2009, clause 7.3.2 4. Arm rest downward static load test-central E 1335-3:2009 AC:2009, clause 7.2.3 5. Arm rest downward static load test - front E 1335-3:2009 AC:2009, clause 7.2.4 6. Arm rest sideways static load test E 1335-3:2009 AC:2009, clause 7.2.5 Page 1 of 2

Sample weight ot determined Sample name: BEETLE 131179 Side view Rear view Bottom view report relates to the sample submitted for the test and no others. Additions, deletions or alterations are not permitted. This test report must always be Page 2 of 2

131179 / 1 Date of test: 22-07-11 VIA CA' LEOCIO, 2 Seat and back static load test 1335-3:2009 AC:2009, clause 7.2.1-7.2.2 Seat front edge static load, clause 7.2.1 Seat depth: foremost position Seat load umber Back rest inclination mechanism 1.600 10 F o defects Seat and back static load test, clause 7.2.2 Back rest in height Back rest in depth Position of castors Tension of mechanism spring: rearmost perpendicular position to the base arms medium Seat load Back force umber Back rest inclination mechanism Back rest inclination mechanism 1.600 560 5 A - B Blocked o defects 1.600 560 5 A - B Unlocked o defects

131179 / 2 Date of test: 22-07-11 VIA CA' LEOCIO, 2 Seat and back durability - E 1335-3:2009 AC:2009 - Clause 7.3.1 Seat and back durability clause 7.3.1 Back rest in height Back rest in depth Position of castors Tension of mechanism spring: rearmost position perpendicular to the base arms medium umber Loading point Force Back rest inclination mechanism 120.000 A 1.500 Unlocked o defects 40.000 40.000 20.000 20.000 20.000 C B C B J E F H D G 1200 320 1200 320 1200 320 1200 320 1100 1100 Blocked Unlocked Unlocked Unlocked Unlocked o defects o defects o defects o defects o defects

131179 / 3 Date of test: 29-08-11 VIA CA' LEOCIO, 2 Arm rests durability E 1335-3:2009 AC:2009, clause 7.3.2 Arm rest durability, clause 7.3.2 lowest position Armrest positioning: // Load on arm rest umber 400 60.000 o defects

131179 / 4 Date of test: 05-09-11 VIA CA' LEOCIO, 2 Arm rest downward static load test-central E 1335-3:2009 AC:2009, clause 7.2.3 Arm rest downward static load test - central, clause 7.2.3 lowest position Armrest positioning: // Load on the arm rest umber 750 5 o defects 900 5 o defects

131179 / 5 Date of test: 05-09-11 VIA CA' LEOCIO, 2 Arm rest downward static load test - front E 1335-3:2009 AC:2009, clause 7.2.4 Arm rest downward static load test - front, clause 7.2.4 lowest position Armrest positioning: // Load on the arm rest umber 450 5 o defects

131179 / 6 Date of test: 05-09-11 VIA CA' LEOCIO, 2 Arm rest sideways static load test E 1335-3:2009 AC:2009, clause 7.2.5 Arm rest sideways static load test, clause 7.2.5 lowest position Armrest positioning: // Horizontal force umber of applications 400 10 o defects