CellTiter-Fluor Cell Viability Assay



Similar documents
GloMax Discover and Explorer. State-of-the-art multimode readers for luminescence, fluorescence and absorbance detection.

ADP/ATP Ratio Assay Kit (Bioluminescent)

V6930, V9101, V9102, V9103 AND V9104

CytoSelect Cell Viability and Cytotoxicity Assay Kit

Proto col. GoClone Repor ter Construc ts: Sample Protocol for Adherent Cells. Tech support: Luciferase Assay System

Optimizing Performance of the Transcreener ADP Assay for the BioTek Synergy 2 and 4 Multi-Mode Microplate Readers

MTT Cell Proliferation Assay

CellTiter 96 AQ ueous One Solution Cell Proliferation Assay

CellTiter 96 AQ ueous One Solution Cell Proliferation Assay INSTRUCTIONS FOR USE OF PRODUCTS G3580, G3581 AND G3582.

Classic Immunoprecipitation

Inc. Wuhan. Quantity Pre-coated, ready to use 96-well strip plate 1 Plate sealer for 96 wells 4 Standard (liquid) 2

CellTiter 96 AQ ueous One Solution Cell Proliferation Assay INSTRUCTIONS FOR USE OF PRODUCTS G3580, G3581 AND G3582.

Measuring Cell Viability/Cytotoxicity: Cell Counting Kit-F

LightSwitch Dual Assay System DA010 (100 assays)

Protein extraction from Tissues and Cultured Cells using Bioruptor Standard & Plus

Rat creatine kinase MM isoenzyme (CK-MM) ELISA Kit

GLOMAX G TIONSU INSTRUMENTS

Rat creatine kinase MM isoenzyme (CK-MM) ELISA Kit

SmartFlare RNA Detection Probes: Principles, protocols and troubleshooting

Human Free Testosterone(F-TESTO) ELISA Kit

Hydrogen Peroxide Cell-Based Assay Kit

Glycolysis Cell-Based Assay Kit

Rat Creatine Kinase MB isoenzyme,ck-mb ELISA Kit

Creatine Kinase Activity Assay Kit (Colorimetric)

CFSE Cell Division Assay Kit

ab Protein Sumoylation Assay Ultra Kit

HighPure Maxi Plasmid Kit

Fighting the Battles: Conducting a Clinical Assay

ArC Amine Reactive Compensation Bead Kit

AxyPrep TM Mag PCR Clean-up Protocol

Rat Creatine Kinase MB Isoenzyme (CKMB) ELISA

Mouse krebs von den lungen 6 (KL-6) ELISA

The kit is a sandwich enzyme immunoassay for in vitro quantitative measurement of PST in mouse tissue homogenates and other biological fluids.

Uscn Life Science Inc. Wuhan

Canine creatine kinase MB isoenzyme (CK-MB)ELISA Kit

Optimized Protocol sirna Test Kit for Cell Lines and Adherent Primary Cells

CellTiter 96 Non-Radioactive Cell Proliferation Assay INSTRUCTIONS FOR USE OF PRODUCTS G4000 AND G4100.

protocol handbook 3D cell culture mimsys G hydrogel

Western Blot Analysis with Cell Samples Grown in Channel-µ-Slides

Transfection reagent for visualizing lipofection with DNA. For ordering information, MSDS, publications and application notes see

Maxwell 16 Blood DNA Purification System

Application Guide... 2

EdU Flow Cytometry Kit. User Manual

Data Sheet. PD-L1:B7-1[Biotinylated] Inhibitor Screening Assay Kit Catalog # Size: 96 reactions

Islet Viability Assessment by Single Cell Flow Cytometry

Instructions. Torpedo sirna. Material. Important Guidelines. Specifications. Quality Control

Creatine Kinase Activity Colorimetric Assay Kit ABE assays; Store at -20 C

Creatine Kinase (CK) Enzymatic Assay Kit Manual Catalog #:

Wizard DNA Clean-Up System INSTRUCTIONS FOR USE OF PRODUCT A7280.

UltraClean PCR Clean-Up Kit

Mouse glycated hemoglobin A1c(GHbA1c) ELISA Kit

DNA IQ System Database Protocol

Application Note No. 2 / July Quantitative Assessment of Cell Quality, Viability and Proliferation. System

Mouse Creatine Kinase MB isoenzyme (CKMB) ELISA

RayBio Creatine Kinase (CK) Activity Colorimetric Assay Kit

Transformation Protocol

Cell Culture Protocol for Biogelx Peptide Hydrogel 2D and 3D Cell Culture PRO/BGX/001

P i Per Pyrophosphate Assay Kit

How To Use An Enzymatics Spark Dna Sample Prep Kit For Ion Torrent

Reagents Quantity Reagents Quantity. Pre-coated, ready to use 96-well strip plate 1 Plate sealer for 96 wells 4. Standard 2 Standard Diluent 1 20mL

Instructions For Research Use Only. Not For Use In Diagnostic Procedures

Western Blot Protocol Protein isolation

Assembly of Restriction Enzyme Digestions

Mouse Insulin ELISA. For the quantitative determination of insulin in mouse serum and plasma

HBV Quantitative Real Time PCR Kit

FOR REFERENCE PURPOSES

Cell Cycle Phase Determination Kit

UltraClean Forensic DNA Isolation Kit (Single Prep Format)

How To Get Rid Of Small Dna Fragments

How To Make A Tri Reagent

Radius 24-Well Cell Migration Assay (Laminin Coated)

PROTOCOL. Immunostaining for Flow Cytometry. Background. Materials and equipment required.

PowerFecal DNA Isolation Kit

TECHNICAL BULLETIN. HIS-Select Nickel Affinity Gel. Catalog Number P6611 Storage Temperature 2 8 C

Cell Migration, Chemotaxis and Invasion Assay Protocol

Seahorse XF Cell Mito Stress Test Kit

TransIT Transfection Reagent

Canine Creatine Kinase MM isoenzyme(ck-mm) ELISA. kit

UltraClean Soil DNA Isolation Kit

ab83369 Alkaline Phosphatase Assay kit (Colorimetric)

Bovine Vitamin B12 (VB12) ELISA Kit

Frozen-EZ Yeast Transformation II Catalog No. T2001

ab Propidium Iodide Flow Cytometry Kit for Cell Cycle Analysis

NCL Method ITA-6. Leukocyte Proliferation Assay

Modulating Glucose Uptake in Skeletal Myotubes:

ab Hi-Fi cdna Synthesis Kit

Mouse Keyhole Limpet Hemocyanin antibody(igm) ELISA Kit

For the rapid, sensitive and accurate measurement of ATP in various samples.

TECHNICAL BULLETIN. Angiotensin II EIA Kit for serum, plasma, culture supernatant, and cell lysates. Catalog Number RAB0010 Storage Temperature 20 C

Genomic DNA Extraction Kit INSTRUCTION MANUAL

CytoSelect 48-Well Cell Adhesion Assay (ECM Array, Fluorometric Format)

Malachite Green Phosphate Assay Kit

Wizard SV Gel and PCR Clean-Up System

TECHNICAL BULLETIN. Glucagon EIA Kit for serum, plasma, culture supernatant, and cell lysates. Catalog Number RAB0202 Storage Temperature 20 C

Annexin V-FITC Apoptosis Detection Kit

Effects of Antibiotics on Bacterial Growth and Protein Synthesis: Student Laboratory Manual

GASTRIC ORGANOID CULTURE PROTOCOL

Human Adult Mesothelial Cell Manual

TaqMan Fast Advanced Master Mix. Protocol

MLX BCG Buccal Cell Genomic DNA Extraction Kit. Performance Characteristics

Transcription:

TECHNICAL BULLETIN CellTiter-Fluor Cell Viability Assay Instructions for Use of Products G6080, G6081 and G6082 Revised 8/15 TB371

CellTiter-Fluor Cell Viability Assay All technical literature is available at: www.promega.com/protocols/ Visit the web site to verify that you are using the most current version of this Technical Bulletin. E-mail Promega Technical Services if you have questions on use of this system: techserv@promega.com 1. Description...1 2. Product Components and Storage Conditions...4 3. Reagent Preparation and Storage...5 4. Protocols for the CellTiter-Fluor Cell Viability Assay...5 4.A. Determining Assay Sensitivity, Method 1...6 4.B. Determining Assay Sensitivity, Method 2...7 4.C. Example Viability Assay Protocol...8 4.D. Example Multiplex Assay Protocol (with luminescent caspase assay)...9 4.E. Recommended Controls... 10 5. General Considerations... 10 6. References... 11 7. Related Products... 12 8. Summary of Changes... 12 1. Description The CellTiter-Fluor Cell Viability Assay (a) is a nonlytic, single-reagent-addition fluorescence assay that measures the relative number of live cells in a culture population after experimental manipulation (Figures 1 and 2). The CellTiter-Fluor Cell Viability Assay measures a conserved and constitutive protease activity within live cells and therefore serves as a marker of cell viability (1). Results obtained using the CellTiter-Fluor Cell Viability Assay correlate well with other established methods of determining cell viability (Figure 3). The live-cell protease activity is restricted to intact viable cells and is measured using a fluorogenic, cell-permeant, peptide substrate (glycyl-phenylalanyl-aminofluorocoumarin; GF-AFC). The substrate enters intact cells where it is cleaved by the live-cell protease activity to generate a fluorescent signal proportional to the number of living cells (Figure 4). This live-cell protease becomes inactive upon loss of cell membrane integrity and leakage into the surrounding culture medium. The CellTiter-Fluor Cell Viability Assay also can be used in a single-well, sequential, multiplex format with other downstream chemistries to normalize data by cell number. Data from the assay can serve as an internal control and allow identification of errors resulting from cell clumping or compound cytotoxicity. Promega Corporation 2800 Woods Hollow Road Madison, WI 53711-5399 USA Toll Free in USA 800-356-9526 608-274-4330 Fax 608-277-2516 1 www.promega.com TB371 Revised 8/15

The CellTiter-Fluor Cell Viability Assay is compatible with most Promega luminescence assays or spectrally distinct fluorescence assay methods, such as assays measuring caspase activation, reporter gene expression or orthogonal measures of viability. However, some P450-Glo multiplex protocols may require removing culture supernatant to a separate assay well before performing the assay because of isoform-specific competitive inhibition of the cytotochrome P450 enzymes by the coumarin product of the CellTiter-Fluor Cell Viability Assay reaction. Add GF-AFC Substrate to Assay Buffer to create the CellTiter-Fluor Reagent. GF-AFC Substrate Assay Buffer CellTiter-Fluor Reagent Add reagent to plate in proportional volumes, mix and incubate. Measure fluorescence. 6868MA Figure 1. Schematic diagram of the CellTiter-Fluor Cell Viability Assay. 2 Promega Corporation 2800 Woods Hollow Road Madison, WI 53711-5399 USA Toll Free in USA 800-356-9526 608-274-4330 Fax 608-277-2516 TB371 Revised 8/15 www.promega.com

Assay Benefits Measure the Relative Number of Live Cells in Culture: Nonlytic, single-reagent-addition, homogeneous, add-mix-measure protocol. Get More Data from Every Well: The CellTiter-Fluor Cell Viability Assay can be performed in multiplex with most Promega luminescence assays. Normalize Data for Cell Number: Normalizing data for live-cell number makes results more comparable well-to-well, plate-to-plate, day-to-day. GF N H CF 3 LIVE-CELL SUBSTRATE: cell-permeant fluorogenic O O substrate for the live-cell protease (Gly-Phe-AFCoumarin) Live-cell protease substrate can cross the cell membrane. Active Live-Cell Protease H 2 N Nucleus GF CF 3 O O Live Cell 6995MA Figure 2. CellTiter-Fluor Cell Viability Assay chemistry. The cell-permeant substrate enters the cell, where it is cleaved by the live-cell protease activity to produce the fluorescent AFC. The live-cell protease is labile in membranecompromised cells and cannot cleave the substrate. A. B. ATP-Based Assay Luminescence (RLU) Resorufin Fluorescence (RFU) 160,000 120,000 r 2 = 0.9923 80,000 40,000 0 250 750 1,250 1,750 2,250 2,750 GF-AFC Fluorescence (RFU) 3,100 3,000 r 2 = 0.963 2,900 2,800 2,700 2,600 2,500 500 600 700 800 900 1,000 1,100 GF-AFC Fluorescence (RFU) 6867MA Figure 3. The CellTiter-Fluor Cell Viability Assay shows strong correlation with established methods for measuring viability. Panel A. The GF-AFC Substrate signal from serial dilutions of live cells plotted against results from the CellTiter-Glo Luminescent Cell Viability Assay (Cat.# G7570), which measures cellular ATP. Panel B. The GF-AFC Substrate signal from serial dilutions of live cells plotted against results achieved using the CellTiter-Blue Cell Viability Assay (Cat.# G8080). Promega Corporation 2800 Woods Hollow Road Madison, WI 53711-5399 USA Toll Free in USA 800-356-9526 608-274-4330 Fax 608-277-2516 3 www.promega.com TB371 Revised 8/15

7,500 AFC Fluorescence (RFU) 6,500 5,500 4,500 3,500 2,500 1,500 Viable Treated 500 0 2,000 4,000 6,000 8,000 10,000 12,000 Cells or Cell Equivalents/Well 6866MA Figure 4. The CellTiter-Fluor Cell Viability Assay signal derived from viable cells (untreated) is proportional to cell number. Dead cells (treated) do not contribute appreciable signal in the assay. 2. Product Components and Storage Conditions PRODUCT SIZE CAT.# CellTiter-Fluor Cell Viability Assay 10ml G6080 Cat.# G6080 contains sufficient reagents for 100 assays at 100µl/assay in a 96-well plate format or 400 assays at 25µl/assay in a 384-well plate format. Includes: 1 10ml Assay Buffer 1 10µl GF-AFC Substrate (100mM in DMSO) PRODUCT SIZE CAT.# CellTiter-Fluor Cell Viability Assay 5 10ml G6081 Cat.# G6081 contains sufficient reagents for 500 assays at 100µl/assay in a 96-well plate format or 2,000 assays at 25µl/well in a 384-well format. Includes: 5 10ml Assay Buffer 5 10µl GF-AFC Substrate (100mM in DMSO) PRODUCT SIZE CAT.# CellTiter-Fluor Viability Assay 2 50ml G6082 Cat.# G6082 contains sufficient reagents for 1,000 assays at 100µl/assay in a 96-well plate format or 4,000 assays at 25µl/well in a 384-well format. Includes: 2 50ml Assay Buffer 2 50µl GF-AFC Substrate (100mM in DMSO) Storage Conditions: Store the CellTiter-Fluor Cell Viability Assay components at 20 C. See product label for expiration date. 4 Promega Corporation 2800 Woods Hollow Road Madison, WI 53711-5399 USA Toll Free in USA 800-356-9526 608-274-4330 Fax 608-277-2516 TB371 Revised 8/15 www.promega.com

3. Reagent Preparation and Storage 1. Completely thaw the CellTiter-Fluor Cell Viability Assay components in a 37 C water bath. Vortex the GF-AFC substrate to ensure homogeneity, then briefly centrifuge for complete substrate volume recovery. 2. Transfer the GF-AFC Substrate (10µl for Cat.# G6080 and G6081; 50µl for Cat.# G6082) into the Assay Buffer container (10ml for Cat.# G6080 and G6081; 50ml for Cat.# G6082) to form a 2X Reagent. Mix by vortexing the contents until the substrate is thoroughly dissolved. Note: The solution may initially appear milky when the GF-AFC substrate is delivered to the buffer. This is normal. The substrate will dissolve with vortexing. The CellTiter-Fluor Reagent may be scaled to accommodate the volumes required for downstream multiplexes. To do this, use 1/5 the volume of buffer when you prepare the reagent (i.e., 10µl of the GF-AFC Substrate in 2ml of Assay Buffer). Be sure to label the bottle to indicate that this is a more concentrated reagent, suitable for multiplex assays. Add the reagent at 1/5 the volume of the cell culture. Storage: The CellTiter-Fluor Viability Reagent should be used within 24 hours if stored at room temperature. Unused GF-AFC Substrate and Assay Buffer can be stored at 4 C for up to 7 days with no appreciable loss of activity. 4. Protocols for the CellTiter-Fluor Cell Viability Assay Materials to Be Supplied by the User 96-, 384-, or 1536-well opaque-walled tissue culture plates compatible with fluorometer (clear or solid bottom) multichannel pipettor or liquid-dispensing robot reagent reservoirs fluorescence plate reader with filter sets for AFC (380 400nm Ex /505 Em ) orbital plate shaker compound known to cause 100% cytotoxicity or lytic detergent (digitonin, Calbiochem Cat.# 300410 or Sigma-Aldrich Cat.# D141 at 20mg/ml in DMSO). If you have not performed this assay on your cell line previously, we recommend determining assay sensitivity using your cells and one of the two methods described below (Section 4.A or 4.B). If you do not need to determine assay sensitivity for your cells, proceed to Section 4.C. Promega Corporation 2800 Woods Hollow Road Madison, WI 53711-5399 USA Toll Free in USA 800-356-9526 608-274-4330 Fax 608-277-2516 5 www.promega.com TB371 Revised 8/15

4.A. Determining Assay Sensitivity, Method 1 1. Harvest adherent cells (by trypsinization, etc.), wash with fresh medium (to remove residual trypsin) and resuspend in fresh medium. Note: For cells growing in suspension, proceed to Step 2. 2. Determine the number of viable cells by trypan blue exclusion using a hemacytometer, then adjust them by dilution to 100,000 viable cells/ml in at least 3.0ml of fresh medium. Note: Concentrate the cells by centrifuging and removing medium if the cell suspension is less than 100,000 cells/ml. 3. Add 100µl of the 100,000 cell/ml dilution (10,000 cells/well) to all wells of rows A and B in a 96-well plate (Table 1). 4. Add 100µl of fresh medium to all wells in rows B H. 5. Using a multichannel pipettor, mix the cell suspension in row B by pipetting (being careful not to create foaming or bubbles). Transfer 100µl from row B to row C. Repeat mixing and transfer 100µl from row C to row D. Continue this process to row G. After mixing the diluted suspension at row G, aspirate 100µl from wells and discard it. This procedure dilutes your cells from 10,000 cell/well in row A to 156 cells/well in row G. Row H will serve as the no-cell, background control. Table 1. Schematic of 96-Well Plate Layout. 1 2 3 4 5 6 7 8 9 10 11 12 A 10,000 1 cells/well B C D E F G H 5,000 cells/well 2,500 cells/well 1,250 cells/well 625 cells/well 313 cells/well 156 cells/well 0 cells/well 6. Dilute digitonin to 300µg/ml in water. Using a multichannel pipet, carefully add 10µl of the diluted digitonin to all wells of columns 7 12 to lyse cells (treated samples). Add 10µl of water to all wells of columns 1 6 to normalize the volume (untreated cells). 7. Add 100µl of the CellTiter-Fluor Reagent to all wells, mix briefly by orbital shaking and incubate at 37 C for at least 30 minutes. Note: Longer incubations may improve assay sensitivity and dynamic range. However, do not incubate longer than 3 hours, and be sure to shield plates from ambient light. 6 Promega Corporation 2800 Woods Hollow Road Madison, WI 53711-5399 USA Toll Free in USA 800-356-9526 608-274-4330 Fax 608-277-2516 TB371 Revised 8/15 www.promega.com

8. Measure resulting fluorescence with a fluorometer (380 400nm Ex /505nm Em ) Note: You may need to adjust instrument gains (applied photomultiplier tube energy). 9. Calculate the practical sensitivity for your cell type by making a signal-to-noise calculation for each dilution of cells (10,000 cells/well; 5,000 cells/well; 2,500 cells/well, etc.). Viability S:N = (Average Untreated Average Treated) Std. Dev. of H-1 through H-6 Note: The practical level of assay sensitivity for the assay is a signal-to-noise ratio of greater than 3 standard deviations (derived from reference 1). 4.B. Determining Assay Sensitivity, Method 2 1. Harvest adherent cells (by trypsinization, etc.), wash with fresh medium (to remove residual trypsin) and resuspend in fresh medium. Note: For cells growing in suspension, proceed to Step 2. 2. Determine the number of viable cells by trypan blue exclusion using a hemacytometer, then adjust the cells by dilution to 100,000 viable cells/ml in at least 20ml of fresh medium. Note: Concentrate the cells by centrifuging and removing medium if the pool of cells is less than 100,000 cells/ml. 3. Divide the volume of diluted cells into separate tubes. Subject one tube to moderate sonication (empirically determined by postsonication morphological examination) to rupture cell membrane integrity and to simulate a 100% dead population. The second tube of untreated cells will serve as the maximum viable population. 4. Create a spectrum of viability by blending sonicated and untreated populations in 1.5ml microcentrifuge tubes as described in Table 2. Table 2. Spectrum of Viability Generated by Blending Sonicated and Untreated Cells. Percent Viability µl Sonicated µl Untreated 100 0 1,000 95 50 950 90 100 900 75 250 750 50 500 500 25 750 250 10 900 100 5 950 50 0 1,000 0 Promega Corporation 2800 Woods Hollow Road Madison, WI 53711-5399 USA Toll Free in USA 800-356-9526 608-274-4330 Fax 608-277-2516 7 www.promega.com TB371 Revised 8/15

4.B. Determining Assay Sensitivity, Method 2 (continued) 5. After mixing each blend by gently vortexing, pipet 100µl of each blend into 8 replicate wells of a 96-well plate. Add the 100% viable cells to column 1, 95% viable to column 2, etc. Add cell culture medium only to column 10 to serve as a no-cell control. 6. Add CellTiter-Fluor Reagent in an equal volume (100µl per well) to all wells, mix briefly by orbital shaking, then incubate for at least 30 minutes at 37 C. Note: Longer incubations may improve assay sensitivity and dynamic range. However, do not incubate longer than 3 hours, and be sure to shield plates from ambient light. 7. Measure resulting fluorescence with a fluorometer (380 400nm Ex /505nm Em ). Note: You may need to adjust instrument gains (applied photomultiplier tube energy). 8. Calculate the practical sensitivity for your cell type by making a signal-to-noise calculation for each blend of cell viability (X = 95, 90%, etc.). Viability S:N = (Average 100% Average X%) Standard Deviation of 0% (viable cells) Note: The practical level of assay sensitivity for the assay is a signal-to-noise ratio of greater than 3 standard deviations (derived from reference 1). 4.C. Example Viability Assay Protocol 1. Set up 96-well assay plates containing cells in culture medium at desired density. 2. Add test compounds and vehicle controls to appropriate wells so that the final volume is 100µl in each well (25µl for a 384-well plate). 3. Culture cells for the desired test exposure period. 4. Add CellTiter-Fluor Reagent in an equal volume (100µl per well) to all wells, mix briefly by orbital shaking, then incubate for at least 30 minutes at 37 C. Note: Longer incubations may improve assay sensitivity and dynamic range. However, do not incubate more than 3 hours, and be sure to shield plates from ambient light. 5. Measure resulting fluorescence using a fluorometer (380 400nm Ex /505nm Em ). Note: You may need to adjust instrument gains (applied photomultiplier tube energy). 8 Promega Corporation 2800 Woods Hollow Road Madison, WI 53711-5399 USA Toll Free in USA 800-356-9526 608-274-4330 Fax 608-277-2516 TB371 Revised 8/15 www.promega.com

4.D. Example Multiplex Assay Protocol (with luminescent caspase assay) 1. Set up 96-well assay plates containing cells in culture medium at the desired density. 2. Add test compounds and vehicle controls to appropriate wells so that the final volume is 100µl in each well (25µl for a 384-well plate). 3. Culture cells for the desired test exposure period. Note: Caspase activation is a transient event dictated by compound potency and cell cycle susceptibility. Time course experiments are often useful for defining peak caspase activity and cytotoxicity. 4. Add 20µl of CellTiter-Fluor Reagent (prepared as 10µl substrate in 2ml Assay Buffer) to all wells, and mix briefly by orbital shaking. Incubate for at least 30 minutes at 37 C. Note: Longer incubations may improve assay sensitivity and dynamic range. However, do not incubate longer than 3 hours, and be sure to shield plates from ambient light. 5. Measure resulting fluorescence using a fluorometer (380 400nm Ex /505nm Em ). Note: You may need to adjust instrument gains (applied photomultiplier tube energy). 6. Add an equal volume of Caspase-Glo 3/7 Reagent prepared as described in Technical Bulletin #TB323 to wells (100 120µl per well), incubate for 30 minutes, then measure luminescence using a luminometer. Viability (GF-AFC Substrate) Apoptosis (Caspase-Glo 3/7 Substrate) 6,000 30,000 Luminescence (RLU) 20,000 10,000 4,000 2,000 Fluorescence (RFU) 0 11 10 9 8 7 log 10 [paclitaxel] M 0 6865MB Figure 5. Multiplex of CellTiter-Fluor Assay and Caspase-Glo 3/7 Assay. The CellTiter-Fluor Reagent was added to wells and viability measured after incubation for 30 minutes at 37 C. Caspase-Glo 3/7 Reagent was added and luminescence measured after a 30-minute incubation (10,000 cells/well). Promega Corporation 2800 Woods Hollow Road Madison, WI 53711-5399 USA Toll Free in USA 800-356-9526 608-274-4330 Fax 608-277-2516 9 www.promega.com TB371 Revised 8/15

4.E. Recommended Controls No-Cell Control: Set up triplicate wells without cells to serve as a control to determine background fluorescence. Untreated Cells Control: Set up triplicate wells with untreated cells to serve as a vehicle control. Add the same solvent used to deliver the test compounds to the vehicle control wells. Optional Test Compound Control: Set up triplicate wells without cells but containing the vehicle and test compound to test for possible interference with the assay chemistry. Positive Control for Viability: Set up triplicate wells containing cells treated with a compound known to be toxic to the cells used in your model system. 5. General Considerations Optical Filters and Instrumentation: Fluorogenic dyes exhibit distinct absorption (excitation) and emission profiles when a light energy source is applied. Most fluorometers or multimode instruments contain optical band-pass filters that restrict the wavelengths of light used to excite a fluorophore and the wavelengths passing through to the detector. Note that deviation from the optimal filter set recommendations (Figure 6) may adversely affect assay sensitivity and performance. 3,500 Excitation Emission 3,000 Fluorescence (RFU) 2,500 2,000 1,500 1,000 500 0 250 300 350 400 450 500 Wavelength (nm) 550 600 650 6864MA Figure 6. Optimal excitation and emission spectra for AFC. Background Fluorescence and Inherent Serum Activity: Tissue culture medium that is supplemented with animal serum may contain detectable levels of the protease marker used to measure live-cells. This protease activity may vary among different lots of serum. To correct for variability, determine background fluorescence using samples containing medium plus serum without cells. Temperature: The generation of fluorescent product is proportional to the live-cell protease activity. The activity of this protease is influenced by temperature. 10 Promega Corporation 2800 Woods Hollow Road Madison, WI 53711-5399 USA Toll Free in USA 800-356-9526 608-274-4330 Fax 608-277-2516 TB371 Revised 8/15 www.promega.com

For best results, we recommend incubating at a constant controlled temperature to ensure uniformity across the plate. After adding reagent and briefly mixing, we suggest one of two options: 1. At 37 C in a water-jacketed incubation module (Me Cour, etc.). Note: Incubation at 37 C in a CO 2 culture cabinet may lead to edge-effects resulting from thermal gradients. 2. At room temperature with or without orbital shaking. Note: Assays performed at room temperature may require more than 30 minutes of incubation for optimal sensitivity. However, do not incubate longer than 3 hours. Assay Controls: In addition to a no-cell control to establish background fluorescence, we recommend including a maximum viability (untreated cells) and maximum cytotoxicity control in the experimental design. The maximum viability control is established by adding vehicle only (used to deliver the test compound to test wells). In most cases, this consists of a buffer system or medium and the equivalent amount of solvent added with the test compound. The maximum cytotoxicity control can be determined using a compound that causes 100% cytotoxicity or a lytic compound added to compromise viability (digitonin). See Section 4.A. Viability Marker Half-Life: The activity of the protease marker found has no half-life in viable cells. Viable cells will process the substrate to liberate the AFC fluorophore. However, when cells lose membrane integrity, the protease activity declines very quickly. Therefore enzymatic instability of the live-cell protease outside of viable cells establishes GF-AFC as a good marker for cell viability. Light Sensitivity: Although the GF-AFC Substrate demonstrates good general photostability, the liberated AFC fluorophore (after contact with protease) can degrade with prolonged exposure to ambient light sources. We recommend shielding the plates from ambient light at all times. Cell Culture Medium: The GF-AFC Substrate is introduced into the test well using an optimized buffer system that mitigates differences in ph from treatment. In addition, the buffer system supports protease activity in a host of different culture media with varying osmolarity. With the exception of media formulations with either very high serum content or phenol red indicator, no substantial performance differences will be observed among media. 6. References 1. Niles, A.L. et al. (2007) A homogeneous assay to measure live and dead cells in the same sample by detecting different protease markers. Anal. Biochem. 366, 197 206. 2. Zhang, J-H. et al. (1999) A simple statistical parameter for use in evaluation and validation of high-throughput screening assays. J. Biomol. Screen. 4, 67 73. Promega Corporation 2800 Woods Hollow Road Madison, WI 53711-5399 USA Toll Free in USA 800-356-9526 608-274-4330 Fax 608-277-2516 11 www.promega.com TB371 Revised 8/15

7. Related Products Cell Viability and CytotoxicityAssays Product Size Cat.# MultiTox-Fluor Multiplex Cytotoxicity Assay 10ml G9200 MultiTox-Glo Multiplex Cytotoxicity Assay 10ml G9270 CytoTox-Glo Cytotoxicity Assay 10ml G9290 CytoTox-Fluor Cytotoxicity Assay 10ml G9260 CellTiter-Glo Luminescent Cell Viability Assay 10ml G7570 CytoTox-ONE Homogeneous Membrane Integrity Assay 1,000 4,000 assays G7891 CellTiter-Blue Cell Viability Assay 20ml G8080 Additional Sizes Available. Apoptosis Assays Product Size Cat.# Caspase-Glo 2 Assay 10ml G0940 Caspase-Glo 6 Assay 10ml G0970 Caspase-Glo 3/7 Assay 10ml G8091 Caspase-Glo 8 Assay 10ml G8201 Caspase-Glo 9 Assay 10ml G8211 Apo-ONE Homogeneous Caspase 3/7 Assay 10ml G7790 Additional Sizes Available. Reporter Gene Assays Product Size Cat.# Bright-Glo Luciferase Assay System 10ml E2610 Steady-Glo Luciferase Assay System 10ml E2510 Additional Sizes Available. 8. Summary of Changes The following change was made to the 8/15 revision of this document: 1. The document design was updated. 12 Promega Corporation 2800 Woods Hollow Road Madison, WI 53711-5399 USA Toll Free in USA 800-356-9526 608-274-4330 Fax 608-277-2516 TB371 Revised 8/15 www.promega.com

(a) Patent Pending. 2007 2015 Promega Corporation. All Rights Reserved. Apo-ONE, Caspase-Glo, CellTiter-Blue, CellTiter-Glo and Steady Glo are registered trademarks of Promega Corporation. BrightGlo, CellTiter-Fluor, CytoTox-Fluor, CytoTox-Glo, CytoTox-ONE and P450-Glo and are trademarks of Promega Corporation. Products may be covered by pending or issued patents or may have certain limitations. Please visit our Web site for more information. All prices and specifications are subject to change without prior notice. Product claims are subject to change. Please contact Promega Technical Services or access the Promega online catalog for the most up-to-date information on Promega products. Promega Corporation 2800 Woods Hollow Road Madison, WI 53711-5399 USA Toll Free in USA 800-356-9526 608-274-4330 Fax 608-277-2516 13 www.promega.com TB371 Revised 8/15