ICON INTEGRATED COMMUNICATIONS OPTICAL NETWORK



Similar documents
c o m m u n i c a t i o n n e t w o r k s

Smart Solutions for Network IP Migration

Failsafe Protection for Utility Critical Infrastructure

SOLUTIONS FOR AN EVOLVING WORLD IMUX T1/E1 Multiplexer. with common logic redundancy IMUX 2000 T1/E1 1

Communication Networks. We are securing the past in a fast moving future. FOX605 multiservice platform.

Your single source for network transmission solutions.

SOLUTIONS FOR AN EVOLVING WORLD IMUX 2000 T1/E1 MDACS. Cross-Connect Switch IMUX 2000 T1/E1 1

EtherDevice Switch EDS-726 Series

Updated March 2013 UCC Ensuring the Reliability of the Electric Power Grid. T1/E1 Multiplexer with Common Logic Redundancy

Power network telecommunication

Cisco SLM Port Gigabit Smart Switch Cisco Small Business Smart Switches

Cisco SLM248P 48-Port 10/ Port Gigabit Smart Switch: SFPs/PoE

Going Critical. How to Design Advanced Security Networks for the Nation s Infrastructure. w w w. G a r r e t t C o m. C o m

4-Port 10/100Mbps with PoE + 1-Port 100FX Industrial Ethernet Switch Wide Temperature

Cisco SLM Port Gigabit Smart Switch Cisco Small Business Smart Switches

Telephone Company Lease Line Elimination. Dewey Day Principal Operational Technology Architect Pacific Gas & Electric

Transporting Legacy Switched Digital Circuits Using a Packet Network

Ethernet Link SGI-2424

SGTech Europe 2015 September 22 th Amsterdam. Pedro Gama, Head of SCADA & Telecom Department at EDP Distribuição, SA

TP-LINK. 24-Port Gigabit Smart PoE Switch with 4 Combo SFP Slots. Overview. Datasheet TL-SG2424P.

Benefits of RPR for Utility Critical Infrastructure Networks

Datasheet. Managed PoE+ Gigabit Switches with SFP. Models: ES W, ES W, ES W, ES W

High-density rack with SNMP management provides E1/T1 and Ethernet services over copper and fiber. Data Sheet

Supports O-Ring (recovery time < 30ms over 250 units of connection) and MSTP(RSTP/STP compatible) for Ethernet

Supports O-Ring (recovery time < 30ms over 250 units of connection) and MSTP(RSTP/STP compatible) for Ethernet

RuggedCom Solutions for

IES-P3073GC Series. Industrial IEC port managed Ethernet switch with 7x10/100Base-T(X) and 3xGigabit combo ports, SFP socket.

Industrial RS-232/ RS-422/ RS-485 over Ethernet Media Converter

WiMAX PacketMAX Introducting

John Ragan Director of Product Management. Billy Wise Communications Specialist

IES-3080/3062 Series. Industrial 8-port managed Ethernet switch. Features. Introduction

4-Port 10/100Mbps with PoE + 1-Port 100FX Industrial Web Smart Switch

Ethernet Link SGI-4844F

16x10/100/1000Base-T(X) ports and 8x100/1000Base-X, SFP socket

10 Port L2 Managed Gigabit Ethernet Switch with 2 Open SFP Slots - Rack Mountable

ABB RTU560A Series CMU & Modules

RGPS-7084GP-P. Industrial 12-port rack-mount managed Gigabit PoE Ethernet switch with 8x10/100/1000Base-T(X) P.S.E. ports and 4x1000Base-X, SFP socket

Hirschmann Switch-Tuning: The new Gigabit OpenRail.

Cisco Small Business Managed Switches

AMETEK s New Broadband FOCUS:

Security & Surveillance Cabling Systems

Cisco Small Business Managed Switches

T200, PTP/IEEE 1588 Grandmaster Clock and

Ixia Director TM. Powerful, All-in-One Smart Filtering with Ultra-High Port Density. Efficient Monitoring Access DATA SHEET

Optimux-134, Optimux-125

JetNet 5428Gv2. Features. Industrial 24FE+4G Gigabit Managed Ethernet Switch INDUSTRIAL ETHERNET RACKMOUNT SWITCH

Fiber Optic Connectivity SECURITY SURVEILLANCE SOLUTIONS. ComNet Managed Ethernet Switches

Datasheet. Managed Gigabit Fiber Switch. Model: ES-12F. Non-Blocking Throughput Switching. High Performance and Low Latency

Ixia xstream TM 10. Aggregation, Filtering, and Load Balancing for qgbe/10gbe Networks. Aggregation and Filtering DATA SHEET

Fiber s Role in the Video Security & Surveillance Network. Curt Carlson Product Manager Transition Networks

ISIO 200. Binary Input/Output (I/O) Terminal with IEC Interface

Loop-IP6702 TDMoEthernet

Cloud-based Wireless LAN for Enterprise, SMB, IT Service Providers and Carriers. Product Highlights. Relay2 Enterprise Access Point RA100 Datasheet

FALCO. Broadband Groomer. F-330 Series. Applications. Access system for:

Cisco Small Business Smart Switches

Extreme Security Threat Protection G2 - Intrusion Prevention Integrated security, visibility, and control for next- generation network protection

Optimux-34, Optimux-25

ECB1220R. Wireless SOHO Router/Client Bridge

Local-Area Network -LAN

1. Communication Network Requirements

Industrial 10/100/1000BASE-T to 100/1000BASE-X SFP Media Converter

IGS-9812GP. Industrial 20-port managed Gigabit Ethernet switch with 8x10/100/1000Base-T(X) ports and 12x100/1000Base-X, SFP socket.

CTP Series Circuit to Packet Platforms

CTS2134 Introduction to Networking. Module 07: Wide Area Networks

INTRODUCTION TO MEDIA CONVERSION

SummitStack in the Data Center

Redundant Gigabit Backbone Adds Speed and Reliability to Industrial Networks

TP-LINK L2 Managed Switch

Optimux-134, Optimux-125

SafeNet Network Encryption Solutions Safenet High-Speed Network Encryptors Combine the Highest Performance With the Easiest Integration and

Cisco SRW2024P 24-Port Gigabit Switch: WebView/PoE Cisco Small Business Managed Switches

FlexDSL MiniFlex. SHDSL.bis and Optical Mini DSLAM. SHDSL.bis and Fiber Up to 300Mbps Ddd. Ethernet. Features

Alcatel-Lucent 1645 AMC Access Mutiplexer Compact. Cost-effective and compact STM-1/4 multiservice metro access

SummitStack in the Data Center

1.3. The network element must have the ability to be configured in a point to point, point to multi point, and daisy chain configuration.

Meraki MS22 / MS42 Cloud Managed Gigabit PoE Switch Family

Power network telecommunication

EAP N Wall Mount Access Point / WDS AP / Universal Repeater

Carrier Ethernet: New Game Plan for Media Converters

1 ABSTRACT 3 2 CORAL IP INFRASTRUCTURE 4

HARTING mcon 1000 Introduction and features

FlexDSL MiniFlex. SHDSL.bis and Optical Mini DSLAM. SHDSL.bis and Fiber Up to 300Mbps Ddd. Ethernet. Features

TP-LINK. 24-Port Gigabit L2 Managed Switch with 4 SFP Slots. Overview. Datasheet TL-SG

How To Build A Network For Mining

Industrial Requirements for a Converged Network

Observer Analysis Advantages

Universal power line carrier

Cisco WAP4410N Wireless-N Access Point: PoE/Advanced Security Cisco Small Business Access Points

ENVIRONMENTAL MONITORING SYSTEM WITH WORLD-WIDE COVERAGE AND BIDIRECTIONAL COMMUNICATION VIA INMARSAT SATELLITE NETWORK

Optimux-45, Optimux-45L Multiplexers for 21E1/28T1 over Fiber or T3

Loop-O9310 4E1 or 4T1 Fiber Optical Mux

Power over Ethernet technology for industrial Ethernet networks

8-port 10/100Base-TX +2-port 100Base-FX Switch. User s Guide

TP-LINK. 24-Port 10/100Mbps + 4-Port Gigabit L2 Managed Switch. Overview. Datasheet TL-SL

P-Series: Purpose Built Business and Mobile Backhaul ONTs

OSIRIS Multi-Service Platform

Loop-O9310 4E1 or 4T1 Fiber Optical Mux

SHEET. Skorpion Managed Ethernet Switch Series. EISK8M Series

FlexGain Platform. Universal Access Platform. SHDSL.bis and Fiber Access Platform Ddd & Management. Features

Transcription:

ICON INTEGRATED COMMUNICATIONS OPTICAL NETWORK

DEPENDABLE COMMUNICATIONS FOR CRITICAL INFRASTRUCTURE 2

Dependable communications are essential for the safe and reliable operation of critical infrastructure. A dependable system requires network resiliency, comprehensive management, robust security, and the flexibility to support your future communications needs. That s why SEL designed the ICON Integrated Communications Optical Network a wide-area networking multiplexer optimized for industrial and utility applications. This unique device blends each of those requirements into one rugged platform, ensuring that you can maximize performance and minimize cost and upgrades. The ICON takes a new approach to solving voice and data communications network design. By combining time-division multiplexing (TDM) and Ethernet with a comprehensive range of data interfaces, the ICON makes it easy to migrate from legacy systems and meet the evolving needs of utility communications. At the same time, SEL-5051 Network Management System (NMS) Software simplifies the challenges of provisioning and maintaining your network. With the ICON, maintaining a reliable and flexible communications infrastructure has never been so easy. Whether it s for substation automation, security surveillance, or monitoring and protecting critical equipment, the ICON is designed and built to address demanding communications needs and operate reliably in extreme environments. The ICON comes in two available form-factors, the standard 19-inch rack mount chassis and the half-width cube chassis. 3

SECURE YOUR COMMUNICATIONS Network security is important, and keeping your system safe from malicious attacks should not be left to chance. By combining features like automatic report generation, user access control, and advanced line encryption, the ICON helps you maintain secure communications across your entire network. SECURE INTERNODE LINKS Eliminate man-in-the-middle attacks by using the optional SEL-8029 Crypto Module on line ports. The Crypto Module provides 2.5 Gbps line rate AES-256 encryption with less than 1 microsecond latency. SECURITY AND CRITICAL INFRASTRUCTURE PROTECTION Protect critical infrastructure and help achieve NERC CIP compliance with SEL-5051 NMS Software, which provides the following tools: Password management Session authentication and encryption Automatic security report generation of all changes made to system settings, firmware, and hardware, including the physical removal of modules and attempts to access disabled Ethernet ports Optional AES-256 encryption MAINTAIN A DEPENDABLE NETWORK When communication is critical, your network must continue to operate as expected. That s why the ICON was designed to withstand harsh environments while exceeding industry standards for substation communications equipment. With features like real-time latency monitoring, redundant line ports and power supplies, and fast network healing, the ICON maintains vital communications even when things go wrong. REAL-TIME LATENCY MONITORING Measure and report data latency of every time-division multiplexing (TDM) channel to ensure critical teleprotection traffic is always transported within set performance limits. NETWORK RESILIENCY Maintain critical services by restoring traffic within 5 milliseconds in the event of a fiber failure. The ICON supports single or multiple ring topologies with single or dual interconnection ties between rings. Point-to-point and linear configurations are also supported. RUGGED AND RELIABLE Designed to operate in harsh environments, the ICON withstands vibration, electrical surges, electrostatic discharge, fast transients, and extreme temperatures. It meets or exceeds IEEE 1613 standards for communications networking devices in electric power substations. Hot-swappable modules and redundant line and power modules ensure communications are maintained in all situations. In the unlikely event of a hardware failure, the ICON comes backed by a ten-year, no-questions-asked warranty the best in the industry and proof of the confidence we have in our product quality and durability. PRECISE TIME DISTRIBUTION Distribute time over a wide-area network with better than 1 microsecond accuracy, even in the event of a GPS failure. Each ICON node comes with an integrated GPS receiver as standard, allowing multiple nodes to be used for network timing. With multiple time references, the ICON network is resilient from a localized GPS outage or equipment failure, such as antenna damage due to a lightning strike. SOLUTION DELIVERY CENTER Ensure that your ICON network will operate as expected before transferring it to the field. The SEL Solution Delivery Center in Pullman, Washington, provides a unique approach to solving the challenge of commissioning large, complex communications networks. At this purpose-built facility, customers can perform factory acceptance testing on their complete ICON network. This eliminates any guesswork during commissioning by allowing the customer to inspect the entire network in one room and request changes before the components are shipped to separate field locations. SEL engineers are also on-hand to provide support. 4

GET THE BEST OF BOTH WORLDS There is a trend to migrate applications to Ethernet to take advantage of the flexibility and ubiquity of the technology. Teleprotection, however, is a class of applications that requires low-latency deterministic communication, which is very difficult to achieve with Ethernet. To solve this problem, the ICON was designed to concurrently support TDM and Ethernet to provide an optimal solution for all applications. This means operators can choose the best network for any situation, without needing to compromise. TDM AND ETHERNET With the ICON, operators can map traffic to TDM or Ethernet streams to choose the best transport solution for each application. You can apply TDM for time-critical applications that require low-latency, deterministic communications. Or, you can apply Ethernet for services that require the flexibility of Internet Protocol (IP)-based point-to-multipoint communications. The ICON s ability to give operators the choice between TDM and Ethernet supports better network traffic management and customization for a wide range of applications. TDM Features: Small form-factor pluggable (SFP) 155 Mbps, 622 Mbps, and 2.5 Gbps optical transceivers with a reach of up to 160 km Optional line port encryption Unidirectional path switch ring with <5 ms switching time Grooming and internal cross connect of DS0 traffic Optical transmit and receive level monitors Laser transmit current monitor Built-in test capabilities Ethernet Features: 10/100BASE-T 1000BASE-FX Power over Ethernet (PoE) MAC table learn, lock, and aging IEEE 802.1Q virtual local-area networks (VLANs) Port-based VLANs Manage latency with eight priority queues per port Ports disabled by default Port mirroring APPLICATION TRAFFIC ISOLATION The ICON is able to segregate different traffic types using TDM or Ethernet pipes (Epipes). You can dedicate isolated bandwidth to specific services, which will prevent high-bandwidth Ethernet applications from consuming all the available resources and reducing network throughput for other services. The Ethernet interfaces support IEEE 802.1Q and port-based VLANs. Video VoIP ETHERNET 2.5 Gbps TRANSPORT BANDWIDTH IEC 61850 TDM SEL RELAY Teleprotection 5

PRODUCT OVERVIEW Protected Line Modules IEEE 1613 Compliant Packaging Server Module Seven Slots for Access Modules (Ethernet Access, Quattro, Transfer Trip, and Crypto Modules Shown) 6

Dual Redundant Power Supplies 7

CUSTOMIZE YOUR SYSTEM WITH MULTIPLE MODULE OPTIONS, THE ICON ALLOWS YOU TO SUPPORT A WIDE RANGE OF TIME-SENSITIVE, DATA-INTENSE, AND LOW-BANDWIDTH APPLICATIONS IN ONE DEVICE. Line Module The Line Module provides the TDM and Ethernet transport interface between adjacent nodes. It contains an integrated switch capable of supporting two 1000 Mbps SFP ports and eight 10/100 Mbps Ethernet copper ports for local Ethernet traffic. Two IRIG-B output ports provide time distribution to connected s. Protected Line Module (PLM) The PLM provides a redundant TDM line interface to ensure communications are maintained in the event of a module failure. Users have the option to install two PLMs in place of the single line module. Server Module The Server Module provides the interface between the ICON and the SEL-5051 NMS Software or third-party SNMP manager. The Server Module also contains a GPS satellite receiver for network timing and for providing the real-time clock for time distribution to connected s. Access Modules Quattro Module provides the interface for as many as four Access Submodules. Ethernet Access Module provides eight 10/100 Mbps Ethernet ports with PoE. Transfer Trip Module provides four contact inputs and four high-speed hybrid contact outputs for direct transfer trip (DTT), all permissive transfer trip applications (POTT, PUTT), and directional comparison blocking and unblocking schemes (DCB, DCUB). Crypto Module provides low-latency AES-256 encryption of the line ports between adjacent ICON nodes and is capable of securing two 2.5 Gbps line channels simultaneously. Access Submodules Data Nx64F provides IEEE C37.94 teleprotection. Async enables EIA-232, EIA-422, and EIA-485 communications. DS1 Async provides an asynchronous DS1/T1 interface. DS1 Sync provides a synchronous DS1/T1 interface. Access Submodules Voice 4-Wire Voice Frequency (VF) provides analog modem communications. 2-Wire FXS and FXO offer analog voice communications for telephone and PBX circuit transport. ONE DEVICE THAT MEETS ALL YOUR COMMUNICATIONS NEEDS 8

MANAGE YOUR NETWORK Whether your network is large or small, keeping it running smoothly can be a challenge. The ICON simplifies this task with SEL-5051 NMS Software an indispensable tool for maintaining a secure, reliable, and efficient communications infrastructure. SEL-5051 NMS SOFTWARE SEL-5051 Software offers the following features for the configuration and management of your ICON network: Graphical Network Representation Provide network discovery and graphical display of a complete ICON network. Users can view the status of each ICON node and associated line links. Configuration Management Provision Ethernet and TDM circuits. Manage firmware upgrades remotely, and schedule upgrades for specific times and dates. Event Management Track administrator and shared user access, and monitor valid and invalid user logon attempts as well as session settings change logs. Alarm Management View, sort, filter, and archive the time-stamped alarm history for each node on the network. SEL-5051 Network Management System Software Security Management Automatically generate security reports for compliance with NERC CIP security logging. Performance Monitoring Monitor the performance of TDM and Ethernet communications using comprehensive network statistics. 9

APPLICATIONS TRANSMISSION LINE PROTECTION Implement current differential protection and direct transfer trip schemes with SEL relays. Communicate between relays with IEEE C37.94 circuits carried over an Integrated Communications Optical Network 2.5 Gbps fiber-optic link. Apply the ICON s Transfer Trip Module to sense or assert contact closures for pilot protection schemes. The ICON network monitors and reports channel latency in real time. Select the shortest path between terminals as the primary path. This ensures that the system always reverts back to your primary configuration in the event of a path failure and subsequent restoration. These features, combined with robust IEEE 1613 environmental operating specifications, make the ICON ideal for critical power applications. Site D Line Current Differential System SEL-311L Site A Site C Line Current Differential System IEEE C37.94 SEL-311L Intersubstation Network ICON With Transfer Trip Module IEEE C37.94 IEEE C37.94 Site B Direct Transfer Trip System SEL-2595 Example of teleprotection of a transmission system. SYNCHROPHASOR COMMUNICATIONS Site A Inspect synchronized phasor measurements (synchrophasors) to provide a real-time measurement of electrical quantities across a power system. These time-synchronized measurements can be used for analysis and control of the power system. The ICON provides all necessary timing and Ethernet communications for synchrophasor information reporting. The ICON distributes time across the entire network and can maintain better than 1 μs accuracy among all terminals in the network. This allows synchrophasor systems to continue to operate accurately even in the event of a local or system-wide GPS failure. Site D Site C GPS Antenna Intersubstation Network IRIG-B Site B IRIG-B Intrasubstation Network IRIG-B IEEE 1588 (future) Example network time distribution application. 10

SECURITY MONITORING Use the ICON to build substation security applications. Fence, motion, panel, and door sensors can connect to the SEL-2440 DPAC Discrete Programmable Automation Controller digital inputs, and strobes, sirens, and substation lighting connect to the control outputs. The ICON network can then communicate information back to a SCADA master. The ICON Ethernet ports support Power over Ethernet (PoE), which allows devices (such as video cameras). Site D SCADA Ethernet Site A Ethernet Intersubstation Network Video Monitoring Station Ethernet Door Alarms Power Over Ethernet Cabinet Alarms Site B SEL-2440 Fence Alarms Ethernet SEL-2440 Power Over Ethernet Cabinet Alarms Fence Alarms Site C LEGACY COMMUNICATIONS AGGREGATION Consolidate legacy DS1 and DS0 circuits between locations onto the ICON WAN to eliminate redundant circuit lease and maintenance costs. Apply the ICON FXS/FXO modules to establish analog telephone, PBX, fax, and modem circuits in every location. Accept channelized DS1 circuits from any source, and groom the individual DS0 circuits to terminate anywhere within the network. 2-Wire FXS/FXO Nx64F DS1 Sync DS1 Nx64F T1 Network 4-Wire VF 2-Wire FXS/FXO 4-Wire VF Modem Modem IEC 61850 NETWORK OPTIMIZATION Ensure optimal performance of IEC 61850 based systems by supporting virtual local-area networks (VLANs) and Ethernet Pipes (Epipes). Epipes can contain and isolate Layer 2 broadcast commands, such as IEC 61850 Generic Object- Oriented Substation Event (GOOSE) messages, from all other noncritical traffic on the network, ensuring very low latency data communications paths between intelligent electronic devices (s). IEC GOOSE A Video/VoIP SCADA Point-to-Point IEC GOOSE B 11

SPECIFICATIONS Line Modules 8020-01 Line Module SFP ports A/B/C/D: 2.5 Gbps Ports E/F: GigE 10/100 Ethernet ports: 8 RJ45 with 4 PoE IRIG-B out: 2 BNC 8021-01 Protected Line Module SFP ports A/B: 155 Mbps, 622 Mbps, or 2.5 Gbps IRIG-B out: 2 BNC Server Module 8030-01 Server Module NMS ports: USB, RJ45 GPS antenna: TNC IRIG-B in: BNC Power Modules 19-Inch Rack Mount Chassis 8011-01 HV AC/DC 120 240 V, IEC C6 Line Cord Supply voltage: 102 264 Vac, 50/60 Hz or 88 300 Vdc 8011-02 HV AC/DC 120 240 V, Terminal Block Supply voltage: 102 264 Vac, 50/60 Hz or 88 300 Vdc 8011-03 MV DC 24 48 V, Terminal Block Supply voltage: 18 56 Vdc Half-Width Cube Chassis 8010-01 HV AC/DC 120 240 V, IEC C6 Line Cord Supply voltage: 102 264 Vac, 50/60 Hz or 88 300 Vdc 8010-02 HV AC/DC 120 240 V, Terminal Block Supply voltage: 102 264 Vac, 50/60 Hz or 88 300 Vdc Access Modules 8035-01 Ethernet Access Module 10/100 Ethernet ports: 8 RJ45 with 4 PoE 8051-01 Data Nx64F Multimode Submodule ST ports: 1 Rx, 1 Tx Standard: IEEE C37.94 8053-01 Data Async Submodule Ports: 2 RJ45 Standards: EIA-232, EIA-422, EIA-485 8065-01 4-Wire VF Submodule Ports: 2 RJ45 8066-01 2-Wire FXS Submodule Port: 1 RJ11 8067-01 2-Wire FXO Submodule Ports: 2 RJ11 8041-01, -04 Transfer Trip Module Commands: 4 8057-01 DS1 Async Submodule Ports: 4 RJ48C 8057-02 DS1 Sync Submodule Ports: 4 RJ48C Other 8029-01 Crypto Module Ports: 4 SFP System Specifications Network Topologies Point-to-point, linear, and multiple rings with single or dual interconnected nodes Path Switching Time <5 ms Convection-Cooled No fans Operating Temperature 20 to +65 C ( 4 to +149 F) Mounting 8", 19", or 23" rack or panel mount Certifications IEEE 1613, IEC 60068, IEC 60255, IEC 61000 MAKING ELECTRIC POWER SAFER, MORE RELIABLE, AND MORE ECONOMICAL SCHWEITZER ENGINEERING LABORATORIES, INC. Tel: +1.509.332.1890 Email: info@selinc.com Web: www.selinc.com 2010 2014 by Schweitzer Engineering Laboratories, Inc. PF00239 20140618