Chlorophyll Content Meter. CCM-200 plus



Similar documents
Temperature Datalogger Users Manual

V2.0 Attendance System Hardware Suite Guide Instructions Manual

LEN s.r.l. Via S. Andrea di Rovereto 33 c.s CHIAVARI (GE) Tel Fax mailto: len@len.it url: http//

Maintaining the Content Server

Release Notes. R&S ZVH4/ZVH8 Cable and Antenna Analyzer

User's Guide DylosLogger Software Version 1.6

User Manual. Thermo Scientific Orion

OPERATION MANUAL. MV-410RGB Layout Editor. Version 2.1- higher

Instruction Manual FL

SubCue Analyzer Software - Introduction

Transmitter Interface Program

GX-2009 Data Logger Management Program Operator s Manual

UPS Monitoring and Management Software

Firmware version: 1.10 Issue: 7 AUTODIALER GD30.2. Instruction Manual

1. Installing The Monitoring Software

Manual Analysis Software AFD 1201

Global Water Instrumentation, Inc.

Capacitive Touch Lab. Renesas Capacitive Touch Lab R8C/36T-A Family

Dash 8Xe / Dash 8X Data Acquisition Recorder

TP- 051 GPS RECEIVER

telstra.com/ppmbb visit a telstra store or partner GETTING TO KNOW YOUR

Table of Contents. 1. Overview Materials Required System Requirements User Mode Installation Instructions..

User's Guide. Integrating Sound Level Datalogger. Model Introduction

BTMPico Data Management Software

Optical Power Meter. Specification & User Manual

SPC-1. Single Point Controller. Operation Manual

SA-9600 Surface Area Software Manual

ProVisual AC-8000P. User Manual. For the optimal use and maintenance of the product, Please read the manual carefully before using it.

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

Network Video Recorder Quick Operation Guide

Leaf River Outdoor Products Vibrashine, Inc. P.O. Box 557 Taylorsville, MS (601) FAX (601)

Dash 18X / Dash 18 Data Acquisition Recorder

ViewPower. User s Manual. Management Software for Uninterruptible Power Supply Systems

PRORAE REMOTE HOST CONTROLLER: COMMUNICATION TROUBLESHOOTING GUIDE

Kit Highlights and Key Features

User's Manual. Heavy Duty Dissolved Oxygen Meter Model

Using the UPSMON-Plus Monitoring Software

D8X / D16X IPHONE INTERFACE

Monitoring Network DMN

KCU-02 Monitor. Software Installation User Manual. For Windows XP and Windows 7

Getting Started. rp5800, rp5700 and rp3000 Models

PPM Users Manual Signature Software

Quick Installation and Setup for WinPower Software

History of Revisions. Ordering Information

Dual Laser InfraRed (IR) Thermometer with Color Alert

Hydras 3 LT Quick Start

Weather Direct Displays show Lost Forecast (blank boxes in the picture icons)

User Manual. Humidity-Temperature Chart Recorder. Model RH520

DVB-T 730. User s Manual

USER MANUAL DataLocker Enterprise

DICKSON PR100/PR300/PR500 DICKSON. Pressure Logger Operation. Contents:

User Guide. Heavy Duty Dissolved Oxygen Meter. Model

GE Measurement & Control

User s Manual. Management Software for Inverter

SOFTWARE GUIDE PM1405 DATA PROCESSING SOFTWARE

Kurz MODBUS Client User s Guide

How To Use 1Bay 1Bay From Awn.Net On A Pc Or Mac Or Ipad (For Pc Or Ipa) With A Network Box (For Mac) With An Ipad Or Ipod (For Ipad) With The

ACS CLIENT SOFTWARE USER MANUAL

Time Attendance V1.4

1. Introduction... 3 Introduction Deal command... 13

Table of Contents MONITORING SOFTWARE USER MANUAL

Dual Laser InfraRed (IR) Thermometer

Operating manual. SpectralTransfer. - Backup of measurement data - Backup and recovery of user-defined methods - Software and methods update

Network Video Recorder Quick Operation Guide

ALOHA Load Balancer Quickstart guide

Parts List. Navigation

Diamante WiFi Wireless Communication User Guide. CradlePoint CTR35

EM6230 e-camview HD outdoor IP camera

VFS24/32HDIP. Public Display IP Monitor User Manual

XPanel V2. Remote Control Panel. User Manual. XILICA Audio Design

Diamante WiFi Wireless Communication User Guide. Linksys E1200

Getting Started on the PC and MAC

AUDITVIEW USER INSTRUCTIONS

Dual Laser InfraRed (IR) Thermometer

ReadyNAS OS 6 Desktop Storage Systems

Using AORUS Notebook for the First Time

Using GIGABYTE Notebook for the First Time

Digital Photo Bank / Portable HDD Pan Ocean E350 User Manual

SNMP Web card. User s Manual. Management Software for Uninterruptible Power Supply Systems

icom Software Update Guide Updating the icom using the Service Tool (ist)

NVMS User Manual

Keep it Simple Timing

OSM 2007 MONITORING SOFTWARE

INSTRUCTION MANUAL MONITOR REDUCE SAVE ENERGY MANAGEMENT SOFTWARE ENERGY MANAGEMENT SOFTWARE

32 Transferring Projects and Data

Digital Camera. LCD Screen. Canon Power Shot A530. Features: Features:

KI6501 Data Manager. Software User Manual

JVC Monitor Calibration 2 User's Guide

Troubleshooting Guide

LCD MONITOR TOUCH PANEL DRIVER 2 OPERATION MANUAL. for Mac. Version 1.0 PN-L703A/PN-70TA3/PN-L703B/PN-70TB3/PN-L603A/PN-60TA3/PN-L603B/PN-60TB3

How To Use An Fsm1

Using GIGABYTE Notebook for the First Time

User Manual Web Operating Panel AP User Manual. General Settings, Updating and Troubleshooting

Tutorial: Configuring GOOSE in MiCOM S1 Studio 1. Requirements

EASE Scan Tool Customers. SECTION I - Installation

Offline Array Recovery Procedures SuperTrak SX6000 and UltraTrak

DSM155 Digital LED Light Meter User s Manual DSM155

psi fth mbar * /0.1 cmh inhg bar

OxySense Gen III Operations Manual

WEA-Base. User manual for load cell transmitters. UK WEA-Base User manual for load cell transmitters Version 3.2 UK

Transcription:

Chlorophyll Content Meter CCM-200 plus

www.apogeeinstruments.com techsupport@apogeeinstruments.com 435.792.4700 Fax: 435.787.8268

Table of Contents Unit Overview...2 About the Instrument... 4 How It Works... 6 System Settings...7 Measurement & Operation... 8 Calibration... 10 Error Codes... 10 Thirty Point Averaging... 11 Send Data... 14 Specifications... 15

Unit Overview The CCM-200 plus is a self-contained, handheld device powered by a 9V alkaline battery. The sample head is located at the top of the instrument. A Liquid Crystal Display (LCD) is located near the center of the unit. The power switch is at the bottom of the front panel. Eight menu/control keys are used to access all program functions. A USB port is located at the bottom right hand side of the case and allows the user to export data to a PC. A RS232 port is included on the bottom for use with GPS, and it can also be used for data transfer. The three green tear shaped buttons are for selecting software defined choices and will be described as buttons. The blue arrow keys are used for scrolling and referred to as arrow keys. Note: The unit has a four minute auto-off feature. When no key is pressed, or test run for four minutes the unit will shut off automatically in order to conserve battery power. www.apogeeinstruments.com 2

Sample Head Display Selection Buttons Arrow Keys On-Off Button USB Port GPS Port (below) 3

About the Instrument The CCM-200 plus Chlorophyll Content Meter is a handheld, battery operated instrument designed for the rapid, non-destructive, determination of chlorophyll content in intact leaf samples. Chlorophyll content is a direct indication of plant health and condition. Obtaining chlorophyll content via non-destructive analysis gives researchers, agronomists, and growers valuable diagnostic information. This data can then be applied to a multitude of crop production and research initiatives such as: nutrient and irrigation management, pest control, environmental stress evaluation, and crop breeding. Measurements are instantaneous and can be done in the field under normal lighting and growing conditions. Ample on-board data-logging and simple, easy to understand measurements further enhance the user s ability to gather and interpret crop health conditions. The USB cable included with the CCM-200 plus allows for data download to a PC for additional analysis. The CCM-200 plus is a remarkable alternative to destructive sampling techniques. It is far less time consuming and allows samples to be monitored multiple times over various stages of an entire growth cycle. The rapid test and data gathering capability is sure to provide a tremendous advantage to all types of research. This innovative pocketsized instrument is destined to play an important role in improving crop yield and producing higher quality foods. www.apogeeinstruments.com 4

5

How It Works Chlorophyll has several distinct optical absorbance characteristics that the CCM-200 plus exploits in order to determine relative chlorophyll concentration. Strong absorbance bands are present in the blue and red but not in the green or infrared bands. The CCM-200 plus uses absorbance to estimate the chlorophyll content in leaf tissue. Two wavelengths are used for absorbance determinations. One wavelength falls within the chlorophyll absorbance range while the other serves to compensate for mechanical differences such as tissue thickness. The meter measures the absorbance of both wavelengths and calculates a Chlorophyll Concentration Index (CCI) value that is proportional to the amount of chlorophyll in the sample. LED spectrum Note: CCI value is a relative chlorophyll value. Absolute chlorophyll content per unit area is not computed. CCM-200 measurements, however, can be correlated to ground/solvent analysis. www.apogeeinstruments.com 6

System Settings At the main test menu, choose System. OSI May 1 1:58:51 Run Data System System settings and diagnostics Setup Back Diag 24hr Time [04:05:00] Date [05/01/2010] Format [MM/DD/YYYY] Exit Edit Key press beep: [On ] Auto power off: [On ] GPS Baud rate: [ 4800] Exit Edit Serial port output Baud rate [ 9600] Exit Edit Time, date, beep, Auto power off, GPS baud rate, and serial port baud rate may be set in the setup mode. CCM200p Diags 1 Z: pd: C: R: I: Exit CCM200p Diags 2 Rp: Ip: Rc: Ic: Exit CCM200p Diags 3 Boot: Fat: Dir: Dt: C: Free: Exit CCM200p Diags 4 Firmware ID V#.## Application ID V#.## Exit By using a combination of green buttons, and arrow keys, the values may be changed. When the parameter of interest is placed at the top of the screen using the arrow keys, select Edit with a green button. Use the arrow keys to select the correct setting, press enter with a green button, and exit the main test menu. CCM200p Diags 5 LOC: -- --.------ DOP: T:N --- --.------ Exit #Sat: Diagnostics are to be used only with factory assistance Call 435.792.4700 for support. 7

Measurement & Operation Described on the following pages are the specifics on how to obtain measurements with the CCM-200 plus as well as the overall instrument operation protocols. Calibration, measurements, memory and data storage management and the five operating modes and each key function are outlined in detail. Measure Turn on the system with the red on-off button. After a few seconds, the main menu screen appears as below. OSI May 1 1:58:51 Run Data System Press Run button. The unit will quickly change to: Test Menu Measure Back Setup Before measuring, use setup to select the correct parameters. Setup Use the arrow keys to scroll through the options. When the option of interest is at the top of the screen, select the edit button. A cursor will appear. Use the arrow keys to highlight your selection. Press the enter button when finished. Exit to the main test menu. www.apogeeinstruments.com 8

Measure, Continued CCM200p Test Setup Save Data:[Yes] Data File:[FILENAME] Exit Edit Test type: [30 point averaging] [1 point no averaging] [30 point std dev] Record 30pt data [Yes] Exit Edit Data Echo Output:[off] GPS Data Logging:[off] Exit Edit Edit data file [Use an existing file] [Use date as name ] [Edit default name ] [Enter a new name ] Back Accept ## files [CCMDATA01] found [CCMDATA02] [CCMDATA03] Cancel Accept New file name: [XXXXXXXX] Use custom measurement units: [Yes] Units file:[logg ] Exit Edit Cancel Accept ## files [FILENAME] found [FILENAME] [FILENAME] Cancel Accept Single point measurement Sample number: #### Type Units Info Exit Storage info: Data File: FILENAME Free Space: ####KB Back This is the main measuring screen for single point measurement. At this screen, place the leaf to be measured between the CCM body and the silver measuring head. Hold until the beep sounds. Test data will appear as shown to the left Chlorophyll Content Index GPS Data LOC: -- --.------ DOP: T:N --- --.------ Back N Sat: -- By pressing info, the information on the left becomes available. If GPS is being used, the second screen is available. 9

Calibration Calibration is required every time the unit is turned on. The unit s detection system needs to check its chamber path. The user has to calibrate or zero the instrument each time the unit is powered up. Calibration happens after the unit is powered up, Run has been selected on the main test menu, and the measure button has been pressed. To calbrate the unit, close the measuring chamber. Important: make sure the chamber is clear of any material. Hold closed until a beep is heard (after about 2-3 seconds), or the release arm message is read on the screen. Once the beep is heard release the chamber arm. The unit will indicate calibration status. Note: If a Cal Error occurs, see following section. Note: Calibration is not needed between measurements, only when the system is powered up. The unit is ready to take another measurement once information is displayed. This includes after automatic shutdown (no activity after four minutes). Error Codes The error code number describes the problem encountered. Light is leaking into the sample chamber. Make sure the chamber is closed tightly. Note: this error may occur if the black gasket material around the chamber gets damaged or worn. Low signal error. This error may occur if there is debris or dirt in the chamber. Clean out the chamber and try again. Sample too Dense. This error may occur in cases where the sample tissue is too thick. No data is recorded when these errors occur. Try repositioning the sample in the chamber. Or, try a thinner sample. In rare cases the sample is simply too thick to get an accurate reading. www.apogeeinstruments.com 10

Thirty Point Averaging Thirty point averaging is used for some nitrogen management schemes. Please refer to the following papers for more details.- (Shapero 2006) (Francis 1999) Go to the main Test Menu and select the setup button. Use the arrow keys to scroll through the various parameters available until the averaging line appears at the top of the page. Select the Edit button, and this line will become highlighted. Use the arrow keys to scroll through the options, select 30 point average by pressing the Enter button. Press the Exit button to go to the main test menu. Return to the main test menu and select measure. CCM200p Test Setup Save Data:[Yes] Data File:[FILENAME] Exit Edit Test type: [30 point averaging] [1 point no averaging] [30 point std dev] Record 30pt data [Yes] Exit Edit Edit data file [Use an existing file] [Use date as name ] [Edit default name ] [Enter a new name] Back Accept Data Echo Output:[off] GPS Data Logging:[off] Exit Edit Use custom measurement units: [Yes] Units file:[logg ] Exit Edit ## files [CCMDATA01] found [CCMDATA02] [ CCMDATA03] Cancel Accept New file name: [XXXXXXXX] Cancel Accept ## files [FILENAME] found [FILENAME] [FILENAME] Cancel Accept 11

First measuring screen for 30 point averaging Sample number: #### Ave ##.# Info Exit Delete Second screen for 30 point averaging used for points 2 through 30 Ave Pt:## ##.# Units Delete Back As each of the thirty measurements is made the number of measurements, and a graph of the measurements appears on the screen. Again, place the leaf under the silver measuring head and press. Hold the head down until you hear a beep. For each measurement point, a line appears on the graph, with the number of measurements made. When finished, the graph is no longer shown, but the average of the thirty measurements is displayed. All measuring points are stored in the measuring file along with averages. The graphs may be reproduced in Excel if desired. www.apogeeinstruments.com 12

Thirty Point Averaging, continued Thirty Point averaging with standard deviation. This option provides that ability to throw out fliers that do not fall within a two-sigma window. After measuring thirty samples, the unit will throw out measurements that do not conform. Replacement measurements will have to be made to bring the total number of measurements up to thirty. This parameter is selected just like thirty point averaging. Use the directions for thirty-point averaging, but select 30 point std dev. Again, a graph is displayed for the measurements. Sample number: #### Ave ##.# Info Exit Delete Ave Pt:## ##.# Units Delete Back 13

Send Data To transfer files from the CCM-200 plus by USB cable This is the recommended way to transfer files because it is the easiest way to do it. There are some files on the unit that are software files, and they should not be touched. If they are manipulated in any way, a software reload may be required. Data Management Connect a USB cable to link to a PC. Access Back Erase Connect USB Cable. After connecting the USB cable, a drive window will probably appear on your PC that has a drive letter at the top of the file. The window asks you to select the correct viewing method. Select Open windows to view files using Windows Explorer. If this window does not appear, then go to Windows Explorer and My Computer. Find the new drive that is usually listed as a letter and then CCM2p. When you see the files on the drive, right click the data files and open the file with Excel. Data may be graphed using Chart Wizard. USB link active Cancel Press cancel before unplugging the USB cable. The message below will appear. Unplug USB cable! Cancel www.apogeeinstruments.com 14

Measured Parameters Ratio of optical transmission at 931 nm (50 nm halfbandwidth) divided by transmission at 653 nm (25 nm half-bandwidth) Measurement Area 71 mm 2 0.95 cm diameter Specifications Radiation Source Two LEDs User Interface 50 mm by 15 mm graphic display screen 8 keys for control and data manipulation Beep-signal for status and warnings Resolution ± 0.1 Chlorophyll Concentration Index (CCI) unit Range 0 to 200 Sample Acquisition Time 2-3 seconds Detectors Two silicon photodiodes with integral amplifiers Storage Capacity Internal datalogging of over 100,000 measurements Input & Output Mini USB port provided for main data transfer RS-232 port can be used as backup data transfer with software RS-232 port can also be used with GPS for integrated measurement 15 Operating Temperature 0-50º C Temperature Drift Temperature compensated source and detector circuitry for minimum drift over full range Input Power Standard 9 V alkaline battery Dimensions 15 by 8.2 by 2.5 cm GPS Option RS-232 port is used for GPS GPS location data is saved with measuring data for each measurement in the file Mass 220 g (with battery) Warranty 1 year against defects in materials and workmanship

Notes www.apogeeinstruments.com 16 435.792.4700

Notes 17

www.apogeeinstruments.com techsupport@apogeeinstruments.com 435.792.4700 Fax: 435.787.8268 www.apogeeinstruments.com 18