Virtualization with the Intel Xeon Processor 5500 Series: A Proof of Concept



Similar documents
Analyzing the Virtualization Deployment Advantages of Two- and Four-Socket Server Platforms

Evaluating Intel Virtualization Technology FlexMigration with Multi-generation Intel Multi-core and Intel Dual-core Xeon Processors.

Comparing Multi-Core Processors for Server Virtualization

Sizing Server Platforms To Meet ERP Requirements

Leading Virtualization 2.0

Implementing and Expanding a Virtualized Environment

Memory Sizing for Server Virtualization. White Paper Intel Information Technology Computer Manufacturing Server Virtualization

Upgrading Data Center Network Architecture to 10 Gigabit Ethernet

A Quantum Leap in Enterprise Computing

Dell Virtualization Solution for Microsoft SQL Server 2012 using PowerEdge R820

Windows Server 2008 R2 Hyper-V Live Migration

Overcoming Security Challenges to Virtualize Internet-facing Applications

The Future of Computing Cisco Unified Computing System. Markus Kunstmann Channels Systems Engineer

A Superior Hardware Platform for Server Virtualization

Re-Hosting Mainframe Applications on Intel Xeon Processor-based Servers

Using Multi-Port Intel Ethernet Server Adapters to Optimize Server Virtualization

Adopting Software-Defined Networking in the Enterprise

Oracle Database Scalability in VMware ESX VMware ESX 3.5

Implementing Cloud Storage Metrics to Improve IT Efficiency and Capacity Management

Quad-Core Intel Xeon Processor

Using VMware VMotion with Oracle Database and EMC CLARiiON Storage Systems

DIABLO TECHNOLOGIES MEMORY CHANNEL STORAGE AND VMWARE VIRTUAL SAN : VDI ACCELERATION

Virtualization strategy for mid-sized businesses. IBM and VMware virtualization benefits for mid-sized businesses

HP ProLiant BL660c Gen9 and Microsoft SQL Server 2014 technical brief

Microsoft Exchange Solutions on VMware

Intel Xeon Processor 5500 Series. An Intelligent Approach to IT Challenges

Leading Virtualization Performance and Energy Efficiency in a Multi-processor Server

Windows Server 2008 R2 Hyper-V Live Migration

White Paper. Recording Server Virtualization

NETAPP WHITE PAPER USING A NETWORK APPLIANCE SAN WITH VMWARE INFRASTRUCTURE 3 TO FACILITATE SERVER AND STORAGE CONSOLIDATION

An Oracle White Paper August Oracle VM 3: Server Pool Deployment Planning Considerations for Scalability and Availability

Intel Data Direct I/O Technology (Intel DDIO): A Primer >

EMC Virtual Infrastructure for Microsoft Applications Data Center Solution

A Platform Built for Server Virtualization: Cisco Unified Computing System

HP SN1000E 16 Gb Fibre Channel HBA Evaluation

Taking Virtualization

Virtualizing SQL Server 2008 Using EMC VNX Series and Microsoft Windows Server 2008 R2 Hyper-V. Reference Architecture

Philips IntelliSpace Critical Care and Anesthesia on VMware vsphere 5.1

Innovativste XEON Prozessortechnik für Cisco UCS

Building the Virtual Information Infrastructure

Brocade and EMC Solution for Microsoft Hyper-V and SharePoint Clusters

OPTIMIZING SERVER VIRTUALIZATION

Technical Paper. Moving SAS Applications from a Physical to a Virtual VMware Environment

Pivot3 Reference Architecture for VMware View Version 1.03

What s New with VMware Virtual Infrastructure

QLogic 16Gb Gen 5 Fibre Channel in IBM System x Deployments

Intel Xeon Processor E5-2600

How To Run Apa Hadoop 1.0 On Vsphere Tmt On A Hyperconverged Network On A Virtualized Cluster On A Vspplace Tmter (Vmware) Vspheon Tm (

RED HAT ENTERPRISE VIRTUALIZATION FOR SERVERS: COMPETITIVE FEATURES

Cloud based Holdfast Electronic Sports Game Platform

Simplify VMware vsphere* 4 Networking with Intel Ethernet 10 Gigabit Server Adapters

VMware Virtual SAN Backup Using VMware vsphere Data Protection Advanced SEPTEMBER 2014

EMC Unified Storage for Microsoft SQL Server 2008

Enterprise Deployment: Laserfiche 8 in a Virtual Environment. White Paper

HBA Virtualization Technologies for Windows OS Environments

EMC Integrated Infrastructure for VMware

Enabling Technologies for Distributed and Cloud Computing

Solution Brief Availability and Recovery Options: Microsoft Exchange Solutions on VMware

The Foundation for Better Business Intelligence

Developing an Enterprise Client Virtualization Strategy

Oracle Database Reliability, Performance and scalability on Intel Xeon platforms Mitch Shults, Intel Corporation October 2011

Power Efficiency Comparison: Cisco UCS 5108 Blade Server Chassis and Dell PowerEdge M1000e Blade Enclosure

Simple, Reliable Performance for iscsi Connectivity

Enabling Technologies for Distributed Computing

Enabling VMware Enhanced VMotion Compatibility on HP ProLiant servers

Intel Ethernet Switch Load Balancing System Design Using Advanced Features in Intel Ethernet Switch Family

MS Exchange Server Acceleration

Power Efficiency Comparison: Cisco UCS 5108 Blade Server Chassis and IBM FlexSystem Enterprise Chassis

HP recommended configuration for Microsoft Exchange Server 2010: HP LeftHand P4000 SAN

The Advantages of Multi-Port Network Adapters in an SWsoft Virtual Environment

High Availability Server Clustering Solutions

Performance Evaluation of VMXNET3 Virtual Network Device VMware vsphere 4 build

Dell Compellent Storage Center SAN & VMware View 1,000 Desktop Reference Architecture. Dell Compellent Product Specialist Team

HP reference configuration for entry-level SAS Grid Manager solutions

How To Connect Virtual Fibre Channel To A Virtual Box On A Hyperv Virtual Machine

How to Configure Intel Ethernet Converged Network Adapter-Enabled Virtual Functions on VMware* ESXi* 5.1

Expert Reference Series of White Papers. Visions of My Datacenter Virtualized

Accelerating Microsoft Exchange Servers with I/O Caching

Accelerating High-Speed Networking with Intel I/O Acceleration Technology

MaxDeploy Ready. Hyper- Converged Virtualization Solution. With SanDisk Fusion iomemory products

Dell PowerEdge Blades Outperform Cisco UCS in East-West Network Performance

SQL Server Consolidation Using Cisco Unified Computing System and Microsoft Hyper-V

Intel Cloud Builder Guide to Cloud Design and Deployment on Intel Xeon Processor-based Platforms

Microsoft SQL Server 2012 on Cisco UCS with iscsi-based Storage Access in VMware ESX Virtualization Environment: Performance Study

Kronos Workforce Central on VMware Virtual Infrastructure

Citrix XenApp Server Deployment on VMware ESX at a Large Multi-National Insurance Company

Deployment Options for Microsoft Hyper-V Server

Best Practice of Server Virtualization Using Qsan SAN Storage System. F300Q / F400Q / F600Q Series P300Q / P400Q / P500Q / P600Q Series

Using EonStor FC-host Storage Systems in VMware Infrastructure 3 and vsphere 4

FOR SERVERS 2.2: FEATURE matrix

VBLOCK SOLUTION FOR SAP: SAP APPLICATION AND DATABASE PERFORMANCE IN PHYSICAL AND VIRTUAL ENVIRONMENTS

Best Practices for Installing and Configuring the Hyper-V Role on the LSI CTS2600 Storage System for Windows 2008

Performance Characteristics of VMFS and RDM VMware ESX Server 3.0.1

How Customers Are Cutting Costs and Building Value with Microsoft Virtualization

Transcription:

White Paper Intel Information Technology Computer Manufacturing Server Virtualization Virtualization with the Intel Xeon Processor 5500 Series: A Proof of Concept Intel IT, together with Intel s Digital Enterprise Group, End User Platform Integration, and Intel s Software and Services Group, conducted proof-of-concept testing and total cost of ownership (TCO) analysis to assess the virtualization capabilities of Intel Xeon processor 5500 series. A server based on Intel Xeon processor X5570 delivered up to 2.6x the performance and up to 2.05x the performance per watt of a server based on Intel Xeon processor E5450, resulting in the ability to support approximately twice as many virtual machines for the same TCO. We also verified seamless live migration between servers based on Intel Xeon processor 5500 series and previous Intel processor generations using VMware Enhanced VMotion* and Intel Virtualization Technology FlexMigration assist. Sudip Chahal, Sudhir S. Bangalore, Raghu Yeluri, Stephen G. Anderson, and Ashok Emani, Intel Corporation June 2009

IT@Intel White Paper Virtualization with the Intel Xeon Processor 5500 Series: A Proof of Concept Executive Summary Our results show that, compared with the previous server generation, two-socket servers based on Intel Xeon processor 5500 series can support approximately 2x as many VMs for the same TCO. Intel IT, together with Intel s Digital Enterprise Group, End User Platform Integration, and Intel s Software and Services Group, conducted proof-of-concept testing and total cost of ownership (TCO) analysis to assess the virtualization capabilities of Intel Xeon processor 5500 series. Our results show that two-socket servers based on Intel Xeon processor 5500 series can offer substantial improvements in virtualization performance and energy efficiency, resulting in lower TCO per virtual machine (VM) in multiple Intel IT virtualization deployment scenarios. We analyzed performance and energy consumption of a two-socket server based on Intel Xeon processor X5570 compared with a server based on Intel Xeon processor E5450 in tests using the vconsolidate virtualization benchmark suite. Based on our test results, we compared TCO for each server. The server based on Intel Xeon processor X5570 delivered: Up to 2.6x faster performance Up to 2.05x better performance per watt, resulting in approximately double the number of VMs in the same data center thermal envelope Approximately 2x the number of VMs for the same TCO We also verified that servers based on Intel Xeon processor 5500 series are live-migrationcompatible with servers based on previous processor generations, using VMware Enhanced VMotion* and Intel Virtualization Technology FlexMigration assist. Our tests show that servers based on Intel Xeon processor 5500 series can deliver significant value and flexibility to Intel IT. We expect to standardize on Intel Xeon processor 5500 series for new two-socket virtualization host servers. 2 www.intel.com/it

Virtualization with the Intel Xeon Processor 5500 Series: A Proof of Concept IT@Intel White Paper Contents Executive Summary...2 Background...3 Proof of Concept...4 Test Setup...4 Results...8 Total Cost of Ownership Analysis...10 Conclusion...11 Authors...12 Acronyms...12 Background Like many IT organizations, Intel IT is pursuing server virtualization to reduce costs and create a more agile, dynamic data center computing environment. As part of this strategy, we test new server platforms to assess their virtualization performance and energy consumption, and analyze how well they help us meet the compute requirements of the Intel business groups we support. We also perform tests to verify virtual machine (VM) live migration compatibility with other server platforms in our virtualized environment. This compatibility enables us to create higher capacity virtualization resource pools that combine servers based on multiple generations of Intel processors. Intel Xeon processor 5500 series, based on the Intel microarchitecture formerly code-named Nehalem, includes new features designed to increase performance and reduce energy consumption. These include Intel Hyper-Threading Technology; Intel Turbo Boost Technology; Intel QuickPath Technology; an integrated memory controller with nextgeneration DDR3 memory; and 8-MB L3 cache. Servers based on the Intel Xeon processor 5500 series can have up to 2.25x the memory capacity compared to the previous server generation. To determine the potential benefits, Intel IT recently performed proof-of-concept (PoC) testing of the virtualization capabilities of two-socket server platforms based on Intel Xeon processor 5500 series in collaboration with Intel s Digital Enterprise Group, End User Platform Integration, and Intel s Software and Services Group. www.intel.com/it 3

IT@Intel White Paper Virtualization with the Intel Xeon Processor 5500 Series: A Proof of Concept Proof of Concept Our PoC focused on a number of critical areas. Virtualization performance and power efficiency. We tested a server based on Intel Xeon processor 5500 series, compared to the previous-generation Intel Xeon processor 5400 series, using a standard benchmark suite. We measured each platform s performance, scalability, and power consumption. Live migration compatibility. We tested live migration between a two-socket server based on Intel Xeon processor 5500 series and two- and four-socket servers based on several other generations of Intel processors using Intel Virtualization Technology (Intel VT) FlexMigration assist and VMware Enhanced VMotion*. Total cost of ownership (TCO) analysis. Based on our performance test results and other factors such as platform and data center costs, we calculated relative virtualization TCO for servers based on Intel Xeon processor 5500 series compared to Intel Xeon processor 5400 series. Test Setup We conducted two separate sets of tests, one to measure virtualization performance and power efficiency, and one to verify live migration compatibility. Virtualization Performance and Power Efficiency We performed testing to compare a two-socket server based on Intel Xeon processor X5570 (2.93 GHz) with a server based on the previous-generation Intel Xeon processor E5450 (3 GHz). We tested each platform s performance, scalability, and power consumption when running a standard virtualization benchmark suite. System specifications are shown in Table 1. For our tests, we required a benchmark suite that: Represented good approximations of IT workloads. Produced objective measurements. Adequately stressed each of the systems. Produced repeatable results. To meet these needs, we selected the vconsolidate benchmark suite. This tests virtualization performance by simulating real server performance in a typical environment. We used vconsolidate (profile-2) to generate consistent application workloads for the performance analysis. 1 The test suite runs consolidated stack units (CSUs), each comprising five simultaneously running VMs, including one idle VM, as shown in Table 2. CSUs can be added to increase the system load and CPU utilization. Our PoC test environment is shown in Figure 1. We connected each tested server to a LAN and to a storage area network (SAN). Also connected to the LAN were driver systems that generated each CSU workload and controller nodes that managed the CSUs. We created a single set of test VMs and migrated it between test systems using the SAN. When running the benchmark tests, we added CSUs until the systems under test attained high system utilization levels in excess of 80 percent levels that we would rarely expect to reach in production. This allowed us to more fully exploit the scalability of each platform. If a system has enough headroom, adding CSUs increases the aggregate throughput of the system, which results in a greater vconsolidate score. We executed three passes of the tests on each system while monitoring CPU utilization and power consumption, and selected the median set of results. For reference, we used the scores from test runs on a reference platform consisting of a two-socket server based on Intel Xeon processor 5160. We analyzed the capabilities of the tested servers by comparing performance, performance-per-unit cost, and performance per watt for each system. Live Migration Compatibility We performed tests of live migration of representative IT workloads between servers based on Intel Xeon processor 5500 series and other Intel server platforms, using Intel VT FlexMigration assist and VMware Enhanced VMotion. Live migration is an essential technology for an agile, dynamic data center environment based on server 1 See www.intel.com/technology/itj/2006/v10i3/7-benchmarking/6- vconsolidate.htm and http://software.intel.com/en-us/videos/ virtualization-performance-testing-with-vconsolidate/. 4 www.intel.com/it

Virtualization with the Intel Xeon Processor 5500 Series: A Proof of Concept IT@Intel White Paper Table 1. Virtualization Performance Test System Specifications Intel Xeon Processor E5450 Number of processors 2 2 Number of cores 4 4 Core frequency 3 GHz 2.93 GHz Intel Xeon Processor X5570 Interconnect 1.33 GHz Front Side Bus (FSB) 6.4 GT/s Intel QuickPath Interconnect Cache 12 MB L2 8 MB L3 RAM 16 GB (8x 2 GB) 667 MHz DDR2 48 GB (12x 4 GB) 1067 MHz DDR3 Intel Virtualization Technology Enabled Enabled Intel Turbo Boost Technology N/A Enabled Intel Hyper-Threading Technology N/A Enabled Hypervisor VMware ESX 4.0 RC2* VMware ESX 4.0 RC2 virtualization. Live migration enables us to perform VM migrations within a server cluster without interrupting the services the VMs are providing. It provides the foundation for advanced data center capabilities such as dynamic load balancing and maintenance without VM downtime. Dynamic load balancing, when combined with failover capabilities that enable fast, automated recovery of VMs, lowers the risk associated with consolidating many VMs onto each VM host. This makes it more feasible to target higher consolidation ratios that fully exploit increasing server performance and capacity. Until recently, successful live migration between servers within a cluster has required the servers to be based on the same generation of processors, with the same instruction set. This limited our ability to implement large resource pools, creating islands of servers and hindering the implementation of advanced data center capabilities. Combined, Intel VT FlexMigration assist and Enhanced VMotion, a feature of VMware ESX 3.5 U2* and subsequent software versions, are designed to overcome this limitation by enabling all servers to expose the same instruction set to applications, even if they are based on different Intel processor generations. This means we can create clusters that combine servers from multiple generations, allowing full implementation of advanced data center capabilities. We can create higher-capacity resource pools that help avoid potential issues with VM performance and response times. We previously performed tests 2 to verify that we could use Intel VT FlexMigration assist to perform live migration of essential Intel IT workloads between two-socket and four-socket servers based on generations of Intel Xeon processors with the Intel Streaming SIMD Extensions (SSE) 3 instruction set Intel Xeon processor 5300 series and Intel Xeon processor 7300 series and the SSE 4.1 instruction Table 2. vconsolidate Consolidated Stack Unit (CSU) Workload Operating System Memory vcpus VM 1 Database 64-bit Microsoft Windows Server 2003* 2.0 GB 2 VM 2 2-bit Microsoft Windows Server 2003* 1.5 GB 2 VM 3 Mail 32-bit Microsoft Windows Server 2003 1.5 GB 1 VM 4 Java* 64-bit Microsoft Windows Server 2003 2. 0 GB 2 VM 5 Idle 32-bit Microsoft Windows Server 2003 0.4 GB 1 vcpu: virtual CPU, VM: virtual machine Storage Frame LUNs Storage Area Network Two- and Four-Socket Servers Systems Under Test CSU n CSU 2 CSU 1 Guest Virtual Machines CSU: consolidated stack unit, LUN: logical unit number, CSU n Controller CSU 2 Controller CSU 1 Controller CSU Client Drivers n CSU Client Driversv U 2 s Local Area Network Figure 1. Virtualization performance test environment. vers CSU 1 Client Drivers 2 See http://communities.intel.com/docs/doc-2538. www.intel.com/it 5

IT@Intel White Paper Virtualization with the Intel Xeon Processor 5500 Series: A Proof of Concept Merom SSE 3 Virtual Machine Application OS Intel Core Microarchitecture Dual/Quad/Multi-Core 4+-Socket, 2-Socket, 1-Socket Virtual Machine SSE: Intel Streaming SIMD Extensions Application OS Nehalem SSE 4.2 Penryn SSE 4.1 Virtual Machine Application Figure 2. Intel Virtualization Technology FlexMigration assist and VMware Enhanced VMotion* enable live migration between servers with different generations of Intel processors. While the individual servers support different instruction sets, only SSE 3 is exposed in compatibility mode. OS set Intel Xeon processor 5400 series and Intel Xeon processor 7400 series. These results verified that we can combine these multiple processor generations within the same cluster. The Intel Xeon processor 5500 series includes the new SSE 4.2 instruction set, which provides additional instructions to boost performance and cut energy consumption. We wanted to verify that, using Intel VT FlexMigration assist and VMware Enhanced VMotion, we can perform live migration of representative IT workloads between servers based on Intel Xeon processor 5500 series and servers based on previous generations of Intel processors that lack SSE 4.2, as shown in Figure 2. Live migration test design We designed our PoC to test a wide variety of configurations and migration scenarios representative of our production IT environment: We used manual and automated migration modes across two different platform architectures (two-socket and four-socket) and three processor generations. We used the server based on Intel Xeon processor X5570 as both a source and destination during migrations We used Intel IT standard 64-bit and 32-bit Microsoft Windows* builds. Our VMs were virtualized servers based on IT-standard configurations for database servers, reporting services, network load balancing, and Web servers. We tested heavily loaded 32-bit and 64-bit VMs. Test system specifications are shown in Table 3. Test workload We employed an Intel IT business reporting application workload as well as VMs from our vconsolidate test workload. The business reporting workload represents a highly utilized set of enterprise reports served to a large number of users. Tests also include some general Web site navigation. The workload includes Table 3. Live Migration Test System Specifications Processor Cores Intel Microarchitecture SSE Core Frequency Interconnect RAM Server Architecture Intel Xeon processor 5148 2 Merom SSE 3 2. 33 GHz 1.33 GHz FSB 16 GB Two socket Intel Xeon processor X5365 4 Merom SSE 3 3 GHz 1.33 GHz FSB 16 GB Two socket Intel Xeon processor X7350 4 Merom SSE 3 2.93 GHz 1.06 GHz FSB 32 GB Four socket Intel Xeon processor X5450 4 Penryn SSE 4.1 3 GHz 1.33 GHz FSB 32 GB Two socket Intel Xeon processor X7460 6 Penryn SSE 4.1 2.67 GHz 1.06 GHz FSB 32 GB Four socket Intel Xeon processor X5570 4 Nehalem SSE 4.1 2.93 GHz 6.4 GT/s Intel QPI 32 GB Two socket FSB: Front Side Bus, Intel QPI: Intel QuickPath Interconnect, SSE: Intel Streaming SIMD Extensions 6 www.intel.com/it

Virtualization with the Intel Xeon Processor 5500 Series: A Proof of Concept IT@Intel White Paper Hypertext Transfer Protocol (HTTP) and network load-balancing traffic and is designed to stress compute, memory, and multiprotocol network capacity within the virtual environment under test. The workload is generated by an external physical driver client. The workload consists of seven VMs: a database reporting server running within a VM, four load-balanced Web servers used to handle user requests, a domain controller, and a network load balancing controller. Test setup The test host servers were connected to a SAN. The servers were also connected to two 1-Gbps LANs used for VMware Enhanced VMotion and for internal communications within our test cluster, as shown in Figure 3. SAN Storage RAID 4 14 Drives Source System Under Test 1 Database Reporting Server 4 vcpus 4 GB RAM 4 Web Servers 2 vcpus each 2 GB RAM Driver Client 1 Domain Controller 1 vcpu 1 GB RAM 1 Network Load Balancing Controller 2 vcpu 2 GB RAM For each test, we installed VMware vsphere 4* on each of the test systems. We created a cluster, enabling VMware Enhanced VMotion Compatibility (EVC)*, and added our test systems to the cluster. Intel VT FlexMigration assist enabled the hypervisor to report the appearance of the same instruction set to the VMs. Figure 3. Live migration test setup. We performed a series of manual and automated live migration tests using different combinations of host servers. We initiated the test by using an external load generator client system to direct application queries to the VMs running the test workload on the selected source host. Once the targeted loading level was attained on the source host, live migration with VMware Enhanced VMotion was initiated. This live migration to the destination host or hosts was initiated either automatically or manually, depending on the test. We monitored the tests until live migration completed successfully. This included verifying that migration completed successfully without VM outage and that application operation was uninterrupted during the live migration. We recorded the time required to complete the migration, and we monitored application performance and related statistics as well as host system utilization information for the duration of each test. We performed two sets of live migration tests: Manual migration. We tested manual migration of our IT business reporting workload between pairs of test servers. In each test, we migrated all seven VMs from the source to the destination server. The server based on Intel Xeon processor X5570 was used as one of the destination servers. Automated Migration. In these tests, the server based on Intel Xeon processor X5570 was used as the source server. We created a VMware Distributed Resource Scheduler* (VMware DRS*) cluster that included all six servers that were described in Table 3. Our www.intel.com/it 7

IT@Intel White Paper Virtualization with the Intel Xeon Processor 5500 Series: A Proof of Concept Performance Performance 7.00 6.00 5.00 4.00 3.00 2.00 1.00 0.00 2.50 2.00 1.50 1.00 0.50 0.00 Server 98.7% 98.7% 99.8% 2.28 2.32 2.27 Performance Relative Performance/Watt Adjusted for Additional RAM 98.7% 1.00 Intel Xeon Processor E5450 (3 GHz) Utilization Test RAM Configuration 5.56 105% 5.91 6.04 89.9% 2.05 Intel Xeon Processor X5570 (2.93 GHz) Measured Power Target RAM Busy, Idle Configuration 6.09 3 CSU 4 CSU 5 CSU 5 CSU 6 CSU 7 CSU 8 CSU Intel Xeon Processor E5450 (3 GHz) Performance CSU: consolidated stack unit Aggregate Performance Comparison Utilization 84.1% 87.3% 89.1% 89.9% Intel Xeon Processor X5570 (2.93 GHz) Figure 4. Performance and utilization with vconsolidate benchmark. Intel internal measurements, April 2009. Estimated Power Busy, Idle Intel Xeon processor E5450 16 (8x 2 GB) 364, 256 32 (8x 4 GB) 376, 268 Intel Xeon processor X5570 48 (12x 4 GB) 451, 246 72 (18x 4 GB) 481, 276 Figure 5. Power consumption and performance per watt. Intel internal measurements, April 2009. 100% 80 60 40 20 0 100% 80 60 40 20 0 Utilization Utilization goal was to show automated load balancing within a cluster of servers based on multiple generations of Intel processors. In each test, we initially loaded multiple VM workloads on the source server. To help ensure this source server was sufficiently loaded with VMs to distribute and load-balance among the servers in the cluster, we added two vconsolidate CSUs as well as our business reporting application. Then we used VMware DRS to automatically migrate the VMs to the other servers in the cluster. In separate tests, we used different VMware DRS cluster modes ranging from 1 (conservative) to 5 (aggressive). With higher settings, the software performed additional migrations to more evenly balance workloads within the cluster, based on the workloads that were running and the capacity of the available servers. Results In our performance tests, the server based on Intel Xeon processor X5570 was considerably more scalable than the server based on the Intel Xeon processor E5450. All of our live migration tests completed successfully. Virtualization Performance and Scalability The server based on Intel Xeon processor X5570 was considerably more scalable than the server based on the Intel Xeon processor E5450, delivering up to 2.6x the aggregate throughput at lower utilization levels. Aggregate throughput on the server based on Intel Xeon processor X5570 continued to increase as we increased the number of CSUs to eight, with utilization at about 90 percent. In contrast, performance on the server based on Intel Xeon processor E5450 reached a maximum with four CSUs, with utilization at about 98 percent. Maximum server throughput and utilization are compared in Figure 4. Performance per Watt We measured power consumed by each server when running the tests. Details are shown in Figure 5. The memory configurations of our two test systems were adequate to evaluate and compare performance. However, in real deployments, we would expect to use slightly larger memory configurations. This additional memory would slightly increase power consumption. Therefore, for our analysis, we created an adjusted power consumption estimate that takes into account this additional memory. Our adjusted estimate was based on 32 GB of RAM on the server based on Intel Xeon processor E5450, and 72 GB on the server based on Intel Xeon processor X5570. We then normalized performance per watt relative to the server based on Intel Xeon processor E5450. Based on the adjusted power 8 www.intel.com/it

Virtualization with the Intel Xeon Processor 5500 Series: A Proof of Concept IT@Intel White Paper consumption, the server based on Intel Xeon processor X5570 with 72 GB of RAM delivered approximately 105 percent better performance per watt compared with the server based on Intel Xeon processor E5450 with 32 GB of RAM. Intel Xeon Processor 5148 SSE 3, 2-socket, 4 cores/cpu Intel Xeon Processor X5365 SSE 3, 2-socket, 4 cores/cpu Live Migration In our manual migration tests, all migrations with VMware Enhanced VMotion completed successfully with no loss of service, as shown in Figure 6. All of our automated migration tests with VMware Enhanced VMotion also completed successfully. As shown in Figure 7, higher VMware DRS settings resulted in an increasing number of migrations, resulting in a redistribution of the VMs among the available servers that reflected each server s relative capacity. The idle VMs were not migrated, even with the most aggressive VMware DRS setting; because idle VMs do not consume processor resources, migrating them does not help balance resource utilization within the cluster. 7 Virtual Virtual Machines Intel Xeon Processor X5570 SSE 4.2, 2-socket, 4 cores/cpu 7 Virtual Virtual Machines SSE: Intel Streaming SIMD Extensions Figure 6. Manual migration results. 7 Virtual Virtual Machines Intel Xeon Processor X5450 SSE 4.1, 2-socket, 4 cores/cpu 7 Virtual Virtual Machines Intel Xeon processor X5570 Intel Xeon processor 5148 Intel Xeon processor X5365 Intel Xeon processor X5450 Intel Xeon processor X7350 Intel Xeon processor X7460 Before Automated Live Migration Java* 1 Java 2 After Automated Live Migration All live migrations completed successfully Aggressive Conservative VMware DRS Setting 1 0 Migrations VMware DRS Setting 2 6 Migrations VMware DRS Setting 3 8 Migrations VMware DRS Setting 4 11 Migrations VMware DRS Setting 5 12 Migrations 1 Java 1 2 Java 2 Mail 1 Web 1 Mail 2 Web 2 Web 1 Web 2 1 Java 1 Idle 1 Web 1 2 Mail 1 Mail 2 Java 2 Idle 2 Web 2 1 2 Mail 1 Java 1 Java 2 Web 1 1 2 Mail 1 Java 1 Java 2 Web 1 Mail 2 Web 2 Mail 2 Web 2 Web 1 Web 2 Web 1 Web 2 vconsolidate workload IT workload : Database, : domain controller, VMware DRS*: VMware Distributed Resource Scheduler*, : network load balancing controller Figure 7. Results of automated migrations. www.intel.com/it 9

IT@Intel White Paper Virtualization with the Intel Xeon Processor 5500 Series: A Proof of Concept Table 4. TCO assumptions Category Assumption Data Center Physical Plant LAN, Storage Area Network (SAN), and Cabling Personnel Space per rack: 25 square feet Depreciation cycle: 15 years Power use: 80 watts per square foot at USD 0.08 per kilowatt-hour Busy time; 12 hours per day Cooling power multiplier: 2.0 Copper and fiber pre-wiring per rack: USD 3,000 over 10 years Gigabit Ethernet (GbE) LAN port costs per server USD 300 over 4 years Fibre Channel (FC) SAN port costs per server: USD 700 over 4 years LAN/SAN ports per server: 7 GbE (LAN), 2 FC (SAN) USD 100,000 per support employee per year One support employee per 250 servers (physical server support only, including installation, break, fix and de-installation). Virtual machine operating system and application support is not included, as it is the same for all alternatives. Total Cost of Ownership Analysis Different groups of users have a variety of business requirements, resulting in multiple virtualization deployment TCO scenarios. Based on our performance test results and other data, we calculated relative TCO of the server based on Intel Xeon processor X5570, compared with the server based on Intel Xeon processor E5450, when used to support each of these TCO scenarios. In our TCO calculations, we assumed that we would deploy typical rack-mounted servers. We compared a server based on Intel Xeon processor X5570 with 72 GB RAM to a server based on Intel Xeon processor E5450 with 32 GB RAM. Our TCO calculations took into account costs in the following areas: Hardware (including configured RAM) and software acquisition; we based our analysis on list prices from major manufacturers Depreciation and amortization Data center annual depreciation and operating expenses Server support personnel LAN, SAN, and cabling Key TCO assumptions are shown in Table 4. 2.5 2.0 1.97 2.11 2.28 Virtualization Deployment TCO Scenarios We focused on two types of scenario and estimated TCO for each platform when supporting each scenario. Results are shown in Figure 8. Number of Virtual Machines 1.5 1.0 0.5 1.00 1.00 1.00 Performance-centric SLA-focused These scenarios emphasize the need to meet performance servicelevel agreements (SLAs). Typical examples include end-of-quarter financial processing and trading applications. IT must meet SLAs that specify response times for interactive applications and completion times for batch jobs. Therefore, application responsiveness or throughput are paramount. 0.0 Memory Capacity-focused Intel Xeon processor E5450 (3 GHz) Intel Xeon processor X5570 (2.93 GHz) Balanced (Performance/Memory) Mix 50:50 Performance-centric Figure 8. Relative number of virtual machines for the same total cost of ownership for different virtualization scenarios. To meet these SLAs, servers must consistently deliver a specific level of performance or throughput. In our TCO analysis, we therefore limited the number of VMs on each server, based on their relative performance in our tests. The server based on Intel Xeon processor X5570 delivered 2.6x the performance of the server based on Intel Xeon processor E5450, so in our TCO model we assumed that it would support a total of 2.6x as many VMs. Our TCO analysis showed that compared with the server based on Intel Xeon processor E5450, the server based on Intel Xeon processor X5570 supported 2.28x as many VMs for the same TCO, due to its increased throughput and greater performance per watt. 10 www.intel.com/it

Virtualization with the Intel Xeon Processor 5500 Series: A Proof of Concept IT@Intel White Paper Memory capacity-focused These scenarios focus on provisioning large numbers of VMs as cost-effectively as possible; performance is secondary. Typically, this means maximizing the number of VMs per system. Examples include systems used for testing and development, and production applications with light transaction loads. Because performance is secondary, the number of VMs per system tends to be constrained by memory capacity rather than processor performance. We assumed that each server could support as many VMs as the host server physical memory could accommodate. The server based on Intel Xeon processor X5570 could support 1.97x as many as the Intel Xeon processor E5450-based server for the same TCO. Balance of performance-centric and memory capacity-focused workloads In situations where a server runs a mix of performancecentric SLA-focused and memory capacity-focused workloads, the server based on Intel Xeon processor X5570 offered a clear TCO advantage. This suggests that this server would also be a good choice if we do not know in advance which workloads the server will be required to support. Blade and specialized server considerations Our TCO analysis is based on mainstream rack-mounted virtualization server configurations. TCO comparisons using blade servers and specialized niche server configurations will depend on the specifics of the server and the target deployment scenario or usage model. Other scenarios The virtualization performance, memory capacity, and power efficiency of servers based on Intel Xeon processor 5500 series makes them well suited for a variety of additional scenarios. In data centers facing constraints in power, cooling, or LAN or SAN ports, servers based on Intel Xeon processor 5500 series can allow us to host more VMs within the same data center capacity. The increased performance and memory capacity also means that we can increase the flexibility and efficiency of our environment by increasing the number of VMs we can include within a cluster. Virtualization and Four-Socket Servers The growing performance and capacity of two-socket servers makes them suitable for many general-purpose enterprise virtualization roles. However, Intel IT has found that some specialized roles require the even greater capacity of four-socket servers. For example, supporting virtualized enterprise resource planning (ERP) systems may require more memory per virtual machine (VM) or a greater processor core count per VM. This means foursocket servers, which have a greater memory capacity and core count than two-socket servers, may be a better fit. We expect that four-socket servers will be able to take on even more demanding virtualization host requirements when the Nehalem microarchitecture, which includes the virtualization hardware assists Intel Virtualization Technology for Directed I/O (Intel VT-d) and Intel Virtualization Technology for Connectivity (Intel VT-c), becomes available in four-socket servers with the planned introduction of Nehalem-EX systems. Conclusion Servers based on Intel Xeon processor 5500 series delivered significant improvements in virtualization performance, energy efficiency, and TCO compared with previous generations. They add significant capacity and flexibility to our virtualization environment: We can integrate them into clusters with other server processor generations and perform live migration across multiple generations, protecting our server investment and creating higher-capacity virtualization resource pools. We expect to standardize on the Intel Xeon processor 5500 series for new twosocket virtualization host servers. www.intel.com/it 11

Authors Sudip Chahal is a compute and storage architect with Intel IT. Sudhir S. Bangalore is a senior engineer with Intel Digital Enterprise Group, End User Platform Integration. Raghu Yeluri is an enterprise architect with Intel Digital Enterprise Group, End User Platform Integration. Stephen G. Anderson is a systems engineer with Intel IT. Ashok Emani is a performance engineer with Intel Software and Services Group. Acronyms VMware DRS VMware Distributed Resource Scheduler ERP enterprise resource planning EVC Enhanced VMotion Compatibility FC Fibre Channel GbE gigabit Ethernet Intel VT Intel Virtualization Technology FlexMigration assist FlexMigration assist Intel VT-c Intel VT-d PoC SAN SLA TCO VM Intel Virtualization Technology for Connectivity Intel Virtualization Technology for Directed I/O proof of concept storage area network service-level agreement total cost of ownership virtual machine Performance tests and ratings are measured using specific computer systems and/or components and reflect the approximate performance of Intel products as measured by those tests. Results have been simulated and are provided for informational purposes only. Results were derived using simulations run on an architecture simulator or model. Any difference in system hardware or software design or configuration may affect actual performance. Buyers should consult other sources of information to evaluate the performance of systems or components they are considering purchasing. For more information on performance tests and on the performance of Intel products, visit www.intel.com/performance/resources/benchmark_limitations.htm. Intel does not control or audit the design or implementation of thirdparty benchmark data or Web sites referenced in this document. Intel encourages all of its customers to visit the referenced Web sites or others where similar performance benchmark data are reported and confirm whether the referenced benchmark data are accurate and reflect performance of systems available for purchase. This paper is for informational purposes only. THIS DOCUMENT IS PROVIDED AS IS WITH NO WARRANTIES WHATSOEVER, INCLUDING ANY WARRANTY OF MERCHANTABILITY, NONINFRINGEMENT, FITNESS FOR ANY PARTICULAR PURPOSE, OR ANY WARRANTY OTHERWISE ARISING OUT OF ANY PROPOSAL, SPECIFICATION OR SAMPLE. Intel disclaims all liability, including liability for infringement of any proprietary rights, relating to use of information in this specification. No license, express or implied, by estoppel or otherwise, to any intellectual property rights is granted herein. Intel, the Intel logo, and Xeon are trademarks of Intel Corporation in the U.S. and other countries. *Other names and brands may be claimed as the property of others. Copyright 2009 Intel Corporation. All rights reserved. Printed in USA 0609/KAR/KC/PDF Please Recycle 321377-001US