EMC Backup and Recovery for Microsoft Exchange 2007 SP2



Similar documents
EMC Backup and Recovery for Microsoft SQL Server

EMC Backup and Recovery for Microsoft SQL Server

EMC Virtual Infrastructure for Microsoft SQL Server

EMC Business Continuity for Microsoft SQL Server 2008

EMC Unified Storage for Microsoft SQL Server 2008

EMC Virtual Infrastructure for Microsoft Applications Data Center Solution

Virtualizing SQL Server 2008 Using EMC VNX Series and Microsoft Windows Server 2008 R2 Hyper-V. Reference Architecture

EMC Integrated Infrastructure for VMware

EMC Virtual Infrastructure for Microsoft Applications Data Center Solution

EMC PERFORMANCE OPTIMIZATION FOR MICROSOFT FAST SEARCH SERVER 2010 FOR SHAREPOINT

EMC Celerra Unified Storage Platforms

EMC Integrated Infrastructure for VMware

EMC BACKUP-AS-A-SERVICE

Virtualized Exchange 2007 Archiving with EMC Xtender/DiskXtender to EMC Centera

EMC Backup and Recovery for Microsoft SQL Server 2008 Enabled by EMC Celerra Unified Storage

EMC Unified Storage for Oracle Database 11g/10g Virtualized Solution. Enabled by EMC Celerra and Linux using NFS and DNFS. Reference Architecture

EMC Backup and Recovery for Microsoft Exchange 2007

Using VMware VMotion with Oracle Database and EMC CLARiiON Storage Systems

Solution Overview 4 Layers...2. Layer 1: VMware Infrastructure Components of the VMware infrastructure...2

EMC Business Continuity for Microsoft SQL Server Enabled by SQL DB Mirroring Celerra Unified Storage Platforms Using iscsi

Evaluation of Enterprise Data Protection using SEP Software

EMC VNX FAMILY. Copyright 2011 EMC Corporation. All rights reserved.

Oracle Database Deployments with EMC CLARiiON AX4 Storage Systems

SIZING EMC VNX SERIES FOR VDI WORKLOAD

CONFIGURATION GUIDELINES: EMC STORAGE FOR PHYSICAL SECURITY

Reference Architecture. EMC Global Solutions. 42 South Street Hopkinton MA

Building the Virtual Information Infrastructure

Microsoft Exchange 2010 on Dell Systems. Simple Distributed Configurations

Brocade and EMC Solution for Microsoft Hyper-V and SharePoint Clusters

EMC Avamar Backup Solutions for VMware ESX Server on Celerra NS Series 2 Applied Technology

Oracle Database Scalability in VMware ESX VMware ESX 3.5

ADVANCED NETWORK CONFIGURATION GUIDE

Leveraging EMC Fully Automated Storage Tiering (FAST) and FAST Cache for SQL Server Enterprise Deployments

EMC VSPEX END-USER COMPUTING

ADVANCED PROTECTION FOR MICROSOFT EXCHANGE 2010 ON EMC VNX STORAGE

HP and Mimosa Systems A system for archiving, recovery, and storage optimization white paper

Windows Server 2008 Hyper-V Backup and Replication on EMC CLARiiON Storage. Applied Technology

EMC Celerra Unified Storage

Using NetApp Unified Connect to Create a Converged Data Center

Cisco and EMC Solutions for Application Acceleration and Branch Office Infrastructure Consolidation

EMC Virtual Infrastructure for SAP Enabled by EMC Symmetrix with Auto-provisioning Groups, Symmetrix Management Console, and VMware vcenter Converter

EMC Celerra NS Series/Integrated

EMC Backup and Recovery for Oracle Database 11g Without Hot Backup Mode using DNFS and Automatic Storage Management on Fibre Channel

IP Storage in the Enterprise Now? Why? Daniel G. Webster Unified Storage Specialist Commercial Accounts

How To Get A Storage And Data Protection Solution For Virtualization

SAP Disaster Recovery Solution with VMware Site Recovery Manager and EMC CLARiiON

Understanding EMC Avamar with EMC Data Protection Advisor

Virtualizing SQL Server 2008 Using EMC VNX Series and VMware vsphere 4.1. Proven Solution Guide

ACCELERATING YOUR IT TRANSFORMATION WITH EMC NEXT-GENERATION UNIFIED STORAGE AND BACKUP

Cost-Effective Storage Solutions for VMware View 4.5 Enabled by EMC Unified Storage

EMC VNXe3200 UFS64 FILE SYSTEM

Using EonStor FC-host Storage Systems in VMware Infrastructure 3 and vsphere 4

MICROSOFT EXCHANGE best practices BEST PRACTICES - DATA STORAGE SETUP

EMC INFRASTRUCTURE FOR CITRIX XENDESKTOP 5.5

Microsoft SQL Server 2005 on Windows Server 2003

MICROSOFT EXCHANGE SERVER 2010 PERFORMANCE REVIEW USING THE EMC VNX5300 UNIFIED STORAGE PLATFORM

Drobo How-To Guide. Use a Drobo iscsi Array as a Target for Veeam Backups

EXCHANGE 2010 DISASTER RECOVERY OPTIONS WITH CROSS-SITE EXCHANGE DAG AND EMC RECOVERPOINT

VDI Without Compromise with SimpliVity OmniStack and Citrix XenDesktop

IOmark- VDI. HP HP ConvergedSystem 242- HC StoreVirtual Test Report: VDI- HC b Test Report Date: 27, April

Microsoft Exchange Solutions on VMware

Redefining Microsoft Exchange Data Management

Virtualizing Oracle Database 10g/11g on VMware Infrastructure

Brocade Solution for EMC VSPEX Server Virtualization

Lab Validation Report

How To Back Up A Computer To A Backup On A Hard Drive On A Microsoft Macbook (Or Ipad) With A Backup From A Flash Drive To A Flash Memory (Or A Flash) On A Flash (Or Macbook) On

EMC Celerra Gateway. Reach new heights of availability, scalability, and flexibility with EMC Celerra Gateway platforms: NS40G and NS-G8

EMC ISILON OneFS OPERATING SYSTEM Powering scale-out storage for the new world of Big Data in the enterprise

Using HP StoreOnce D2D systems for Microsoft SQL Server backups

Redefining Microsoft SQL Server Data Management. PAS Specification

VIDEO SURVEILLANCE WITH SURVEILLUS VMS AND EMC ISILON STORAGE ARRAYS

EMC Business Continuity for VMware View Enabled by EMC SRDF/S and VMware vcenter Site Recovery Manager

EMC Security for Microsoft Exchange Solution: Data Loss Prevention and Secure Access Management

Configuration Maximums VMware Infrastructure 3

Step by Step Guide To vstorage Backup Server (Proxy) Sizing

Virtualizing Microsoft Exchange Server 2010 with NetApp and VMware

System Requirements Version 8.0 July 25, 2013

Is VMware Data Recovery the replacement for VMware Consolidated Backup (VCB)? VMware Data Recovery is not the replacement product for VCB.

Using HP StoreOnce Backup systems for Oracle database backups

Dell PowerVault DL2200 & BE 2010 Power Suite. Owen Que. Channel Systems Consultant Dell

VMware vsphere Data Protection

DELL. Dell Microsoft Windows Server 2008 Hyper-V TM Reference Architecture VIRTUALIZATION SOLUTIONS ENGINEERING

An Oracle White Paper November Backup and Recovery with Oracle s Sun ZFS Storage Appliances and Oracle Recovery Manager

NetBackup for VMware Data Recovery Services to End the Dark Ages of Virtualization

RFP-MM Enterprise Storage Addendum 1

Configuring Celerra for Security Information Management with Network Intelligence s envision

CONFIGURATION GUIDELINES: EMC STORAGE FOR PHYSICAL SECURITY

VIRTUALIZED EXCHANGE 2010 DISASTER RECOVERY ENABLED BY EMC SYMMETRIX VMAX AND VMWARE vcenter SITE RECOVERY MANAGER

Performance Validation and Test Results for Microsoft Exchange Server 2010 Enabled by EMC CLARiiON CX4-960

EMC SYNCPLICITY FILE SYNC AND SHARE SOLUTION

Virtualizing SQL Server 2008 Using EMC VNX Series and Microsoft Windows Server 2008 R2 Hyper-V. Proven Solution Guide

Consolidate and Virtualize Your Windows Environment with NetApp and VMware

VMware Virtual SAN Backup Using VMware vsphere Data Protection Advanced SEPTEMBER 2014

Virtual Desktop Infrastructure (VDI) Overview

DESIGN AND IMPLEMENTATION GUIDE EMC DATA PROTECTION OPTION NS FOR VSPEXX PRIVATE CLOUD EMC VSPEX December 2014

System Requirements. Version 8.2 November 23, For the most recent version of this document, visit our documentation website.

EMC VSPEX END-USER COMPUTING SOLUTION

Physical Security EMC Storage with ISS SecurOS

Transcription:

EMC Backup and Recovery for Microsoft Exchange 2007 SP2 Enabled by EMC Celerra and Microsoft Windows 2008

Copyright 2010 EMC Corporation. All rights reserved. Published February, 2010 EMC believes the information in this publication is accurate as of its publication date. The information is subject to change without notice. Benchmark results are highly dependent upon workload, specific application requirements, and system design and implementation. Relative system performance will vary as a result of these and other factors. Therefore, this workload should not be used as a substitute for a specific customer application benchmark when critical capacity planning and/or product evaluation decisions are contemplated. All performance data contained in this report was obtained in a rigorously controlled environment. Results obtained in other operating environments may vary significantly. EMC Corporation does not warrant or represent that a user can or will achieve similar performance expressed in transactions per minute. No warranty of system performance or price/performance is expressed or implied in this document. Use, copying, and distribution of any EMC software described in this publication requires an applicable software license. For the most up-to-date listing of EMC product names, see EMC Corporation Trademarks on EMC.com. All other trademarks used herein are the property of their respective owners. Part number: H6902 2

Table of Contents Reference architecture overview... 4 Solution architecture... 6 Key components... 9 Validated environment profile... 11 Hardware and software resources... 12 Conclusion... 13 3

Reference architecture overview Document purpose EMC's commitment to consistently maintain and improve quality is led by the Total Customer Experience (TCE) program, which is driven by Six Sigma methodologies. As a result, EMC has built Customer Integration Labs in its Global Solutions Centers to reflect real-world deployments in which TCE use cases are developed and executed. These use cases provide EMC with an insight into the challenges currently facing its customers. This document describes the reference architecture of the EMC Backup and Recovery solution for Microsoft Exchange 2007 SP2 enabled by Windows Server 2008 backup and EMC Celerra. The solution is tested and validated by the EMC network-attached storage (NAS) product validation team. Solution purpose The purpose of this reference architecture is to build and demonstrate the functionality and performance of the Backup and Recovery solution for Microsoft Exchange 2007. This solution utilizes an Exchange 2007 SP2 backup plug-in along with Windows Server 2008 backup to create an application-consistent backup. This reference architecture validates all aspects of the solution and provides guidelines for building similar solutions. This reference architecture is not intended to be a comprehensive guide to every aspect of the Backup and Recovery for Microsoft Exchange 2007 solution. EMC Backup and Recovery for Microsoft Exchange 2007 SP2 - Enabled by EMC Celerra and Microsoft Windows Server 2008 Proven Solution Guide available on Powerlink provides comprehensive information about this solution. This is a confidential document available to EMC employees and partners on Powerlink. The business challenge Managing a company s growing e-mail requirement, while lowering backup data cost without compromising valuable data or service level agreement, presents a large challenge for IT departments. It is also important to restore Exchange data efficiently with minimal impact to other users regardless of the user mailbox size. This demands a solution that is both effective and affordable while maintaining the performance of the Exchange environment. The technology solution It is important to work with an experienced provider of backup and recovery solutions one with a strong track record and the ability to deliver high-quality solutions. EMC has designed various solutions for protecting Microsoft Exchange environments using a wide range of backup technologies and EMC storage platforms. This solution demonstrates how an EMC Celerra platform can be used to design a robust Microsoft Exchange 2007 environment. In this solution, Windows Server 2008 backup is used with an Exchange 2007 backup plug-in to take application-consistent backups of the Exchange 2007 mailbox data on a Celerra Common Internet File System (CIFS) share. 4

This solution demonstrates how an EMC Celerra platform can be used to build a robust Exchange 2007 infrastructure using the native VSS backup plug-in introduced in SP2. This reference architecture describes how EMC Celerra can provide multi-protocol support for Exchange. Internet Small Computer System Interface (iscsi) is provisioned to the database and log files and CIFS is provided for the Exchange backup target. The solution benefits Reduces the number of physical servers Using VMware to virtualize servers helps in reducing the number of physical servers required in an Exchange environment, while improving the manageability and flexibility of the Exchange environment. In this solution, the number of physical server is reduced by 33 percent. Improves backup storage utilization using EMC Celerra deduplication With EMC Celerra s deduplication feature, the physical disk space required is largely reduced for backup data. In this validated solution, the EMC Celerra deduplication feature reduces the backup storage space by 69 percent. All in one solution EMC Celerra has the capability to host FC (Exchange database and logs) and Advanced Technology-Attached (backup file system) drives in one system. It also has the capability to access storage using iscsi (Exchange database and logs) and CIFS (backup target) connectivity. This makes EMC Celerra an ideal platform to host both the Exchange and backup data. Low-cost solution This solution uses built-in backup components in Exchange 2007 SP2 and Windows Server 2008. This reduces the cost of the backup solution. 5

Solution architecture Architecture diagram The following figure shows the overall physical architecture of the solution. Reference architecture overview The validated solution is built using a virtualized Exchange 2007 environment on the EMC Celerra platform. The key components of the reference architecture are: Microsoft Exchange 2007 SP2 EMC Celerra storage VMware vsphere4 Microsoft Windows Server 2008 backup EMC Celerra dedupe A Microsoft Exchange 2007 mailbox server is installed on a VMware ESX 4.0 virtual machine. A Microsoft Exchange 2007 SP2 HUB/CAS server and Microsoft Active Directory are created on another VMware ESX 4.0 server. EMC Celerra NS-120 is used for storing the Exchange database, log files, and backup data. The different connectivity methods used in this solution are: The Exchange database and log drives are accessed by the Exchange mailbox server using the iscsi protocol. The backup destination is accessed using the CIFS protocol. 6

Storage layout The following figure shows how the storage is provisioned in the validated backup and recovery solution. Storage layout overview The validated solution uses storage through iscsi and CIFS protocols. The iscsi protocol is used to provide the storage for the Exchange mailbox database and log files. The CIFS protocol provides access to the area used for the Exchange mailbox backup. To satisfy the Exchange mailbox server performance requirement, the validated solution is configured on 15k revolutions per minute (rpm) FC drives using the building block approach. A building block is defined as two spindles for logs and four spindles for the database. The validated solution uses two building blocks to host Exchange database and log files. The protection level used is RAID 1/0 for high performance. The backup file system is created using Automatic Volume Management (AVM) with a system-defined storage pool CLARATA_ARCHIVE on 7.2k rpm ATA drives. Fourteen low-cost, low-powered ATA drives with RAID 5 protection level are used for the backup area. 7

Network layout The following figure shows the ports on EMC Celerra NS-120 storage. Network layout overview System-wide network design and architecture are outside the scope of this document and solution. This section describes the high-level network architecture of the validated solution. Virtual local area networks The validated solution uses a virtual local area network (VLAN) to segregate network traffic of different types. This improves throughput, manageability, application separation, high availability, and security. A client VLAN network is used to support connectivity between the Microsoft Exchange 2007 SP2 servers and the Outlook client workstations. The same VLAN is used to back up the Exchange data from the Exchange 2007 SP2 mailbox server to EMC Celerra. Two more VLAN networks are used for iscsi connectivity between the Microsoft Exchange 2007 SP2 mailbox server and EMC Celerra. EMC Celerra NS-120 EMC Celerra NS-120 storage arrays contain at least two Data Movers, which can operate independently. Each Data Mover can have a minimum of four Ethernet ports. EMC Celerra NS-120 comes with an integrated CLARiiON CX4-120 storage array, which has two storage processors (SPs). The NS-120 Data Mover ports cge0 and cge1 are used for iscsi traffic and port cge2 is used for CIFS traffic. The Data Mover supports several types of link aggregation for IP traffic. However, in this configuration, no link aggregations or Ethernet channels are configured. As a best practice, the Data Mover network ports connected to the storage network should be dedicated to storage traffic. However, if the ports are not heavily used, they can be shared with non-storage network traffic. EMC recommends monitoring the network to avoid bottlenecks. 8

Key components Introduction This chapter briefly describes the key components of this solution. Validated environment profile on page 11 provides more information on all the components that make up the reference architecture. EMC Celerra unified storage platform EMC Celerra storage is a dedicated network server optimized for files and block access, delivering high-end features in a scalable, easy-to-use package. For high scalability, Celerra storage platforms leverage both the innovative EMC CLARiiON FC RAID storage delivering best-in-class availability and data protection and industry-leading EMC Celerra availability, performance, and ease of management. EMC Celerra storage systems deliver a single-box block and file access offering a centralized point of management for distributed environments. Celerra unified storage systems deliver a single-box block and file solution offering a centralized point of management for distributed environments. This makes it possible to dynamically grow, share, and cost-effectively manage multi-protocol file systems and provide multi-protocol block access. Administrators can take advantage of simultaneous support for network file system (NFS) and CIFS protocols by enabling Windows and Linux/UNIX clients to share files using the Celerra system s sophisticated file-locking mechanisms and by leveraging iscsi or FC for highbandwidth or latency-sensitive applications. This enables customers to dynamically grow, share, and cost-effectively manage multi-protocol file systems as well as provide multi-protocol block access. Customers can take advantage of simultaneous support for NFS and CIFS protocols by enabling Windows and Linux or UNIX clients share files using Data Access in Real Time (DART) operating system s sophisticated file-locking mechanisms. VMware vsphere 4 The new VMware vsphere 4 provides significant performance enhancements that make it easier for organizations to virtualize their most demanding and intense workloads. VMware vsphere 4 includes ESX 4.0 and the vcenter management interface. VMware ESX 4.0 can transform or virtualize the hardware resources of an x64-based computer including the CPU, RAM, hard disk, and network controller to create a fully functional virtual machine that can run its own operating system and applications just like a physical server. Windows Server 2008 backup The Windows 2008 VSS provides a framework to backup NTFS volumes without any I/O interruption to application that uses the volume. The VSS framework coordinates with three different components requestor (Windows Server 2008 backup), writer (Exchange 2007), and provider (component which creates the shadow copy). The Windows Server 2008 backup does not have the ability to coordinate with the Exchange 2007 application to take an application-consistent backup. The Exchange backup plug-in (WSBExchange.exe) that comes with SP2 coordinates between Exchange 2007 application and Windows Server 2008 backup to create Exchange aware backup. 9

The backup has the ability to take full backup and truncate the logs once it is successful. It also has the ability to restore the backup data on the same location as well as an alternate location. The restore process to the original location will automatically handle the recovery process, including dismounting any existing databases and replaying logs into the recovered Exchange database. NOTE The Windows Server 2008 backup along with Exchange 2007 SP2 backup plug-in can take only full and copy backups. Incremental or differential backups are not possible. The Windows Server 2008 built-in backup with basic functionality makes it more appealing to cost-conscious small and medium-size customers that do not have fine granular backup and restore requirements. 10

Validated environment profile Profile characteristics This solution was validated with the following environment profile. Profile characteristic Value Exchange 2007 users 1,000 IOPS per user Exchange database read: write ratio Number of mailbox database per storage group Exchange user mailbox size Number of users per database Microsoft Exchange 2007 databases RAID type, physical drive size, and speed Backup area RAID type, physical drive size, and speed 0.48 (very heavy profile) 1:1 One 500 MB 250 RAID 1/0, 450 GB FC drives (15k rpm) RAID 5, 1 TB, 7.2k rpm SATA disks 11

Hardware and software resources Hardware The following table lists the hardware used to validate this solution. Equipment Quantity Configuration Purpose Storage One EMC Celerra NS-120 unified storage - CLARiiON CX4-120 Two Data Movers 18 of the 450 GB FC drives (15k rpm) 15 of the 1 TB SATA drives (7.2k rpm) Enterprise network switch Virtual servers One One One One Gigabit Ethernet network switch Four vcpu 3.0 GHz processors Three virtual NICs 8 GB RAM Two vcpu 3.0 GHz processors One virtual NIC 4 GB RAM Two vcpu 3.0 GHz processors One virtual NIC 2 GB RAM One array for Exchange data and backup data Mailbox server HUB/CAS server Active Directory Software The following table lists the software used to validate this solution. Software Version VMware ESX server VMware vsphere 4 Microsoft Windows Server Windows 2008 x64 Enterprise Edition SP2 Windows 2008 x32 Standard Edition SP2 Microsoft Exchange Server Exchange 2007 Enterprise Edition 2007 SP2 EMC Celerra DART 5.6.47.11 EMC CLARiiON FLARE 04.29.000.5.003 12

Conclusion Summary The Exchange 2007 SP2 environment s backup and recovery capability is an integral part of an organization to ensure high availability of data and recovery in case of corruption of data. This reference architecture depicts a validated backup and recovery solution for Microsoft Exchange 2007 SP2 using an EMC Celerra and Windows Server 2008 backup. Next steps EMC can help accelerate assessment, design, implementation, and management while lowering the implementation risks and costs of a backup solution for a Microsoft Exchange 2007 environment. To learn more about this and other solutions, contact an EMC representative. 13