A Complete Range of Ankle Brachial Index (ABI) Systems for Peripheral Arterial Disease (P.A.D.) Detection



Similar documents
Nuevos algoritmos diagnósticos de la enfermedad arterial periférica

How To Determine Pad

Lower Extremity Arterial Segmental Physiologic Evaluation

Facts About Peripheral Arterial Disease (P.A.D.)

Non-Invasive Arterial Vascular Testing

GE Healthcare CASE. Cardiac Assessment System for Exercise Testing. Connecting hearts and minds.

GE Healthcare CASE. Cardiac Assessment System for Exercise Testing. Connecting hearts and minds.

Choosing the proper probe for your Doppler

digital Vitals BY MIDMARK vitals

Ultrasound Technologies. PD1v. vascular pocket doppler. Operating Instructions

Measure #195 (NQF 0507): Radiology: Stenosis Measurement in Carotid Imaging Reports National Quality Strategy Domain: Effective Clinical Care

Vascular Technology (VT) Content Outline Anatomy & physiology 20% Cerebrovascular Cerebrovascular normal anatomy Evaluate the cerebrovascular vessels

Now bring the advantages of digital workflow to cardiology

CardioSoft * Diagnostic System

GE Healthcare. The new MAC * 800

Extremity Trauma. William Schecter, MD

KEYPOINT XP EDITION. Invented for Value and Performance. A Good Diagnosis is Half the Cure

Vascular Surgery Interest Group (V-SIG) Toolkit

ICD-10: An Area We Call. Presented by Harry Goldsmith, DPM

SUPERCHARGED. CUSTOM-DESIGNED FOR CARDIOLOGY. Cardiology PACS. Cardiology

GE Healthcare. Size it up. Centricity cardiovascular PACS solution

Improving the Compliance of the Annual Foot Examination and Monofilament Testing in

GE Healthcare. Centricity * PACS with Universal Viewer. Universal Viewer. Where it all comes together.

GE Healthcare. Centricity* PACS and PACS-IW with Universal Viewer. Universal Viewer. Where it all comes together.

Therefore, a physician should only bill for new patient services when the elements of the definition is met.

Blood Pressure Assessment Program Screening Guidelines

Global Surgery Fact Sheet

Company profile. Quote from the analyst of. Company Milestone. Feel the Difference. Tel: Fax:

Neurodiagnostic Equipment Solutions

An abdominal ultrasound produces a picture of the organs and other structures in the upper abdomen.

More than monitoring. Uniting.

The Choice of Successful Businesses

Upper Extremity Arterial Duplex Evaluation

Status Active. Assistant Surgeons. This policy addresses reimbursement for assistant surgical procedures during the same operative session.

UW MEDICINE PATIENT EDUCATION. Aortic Stenosis. What is heart valve disease? What is aortic stenosis?

Doppler. Doppler. Doppler shift. Doppler Frequency. Doppler shift. Doppler shift. Chapter 19

Wireless Network Guide

Neglected Wound/Poor Wound Care

SEPTEMBER IS P.A.D. AWARENESS MONTH

The Flo-Lab Experience

CPT Consumer Friendly Descriptors: Their Use in Engaging Patients in their Health Care

2016 PQRS OPTIONS FOR INDIVIDUAL MEASURES: CLAIMS, REGISTRY

Davis Medical Electronics

OfficePACS Power. Digital Imaging for the Orthopaedic Workflow

Which ViewSonic VDI client is right

Small Business. solutions

Test Content Outline Effective Date: February 6, Cardiac-Vascular Nursing Board Certification Examination

Compactly Powerful. Ultrasound System UGEO PT60A CT-UGEO PT60A-CWW-CMI-0705-EN

Local Coverage Article: Cardiovascular Stress Testing (A53123)

A t h e n s I n s t i t u t e o f U l t r a s o u n d S u n s e t D r i v e A t h e n s G A

GE Healthcare. Rest assured. MAC 5500 resting ECG analysis system

The ultrasound system that sets new standards

Road to 10: The Small Physician s Route to ICD-10. Implementation Guide

Visionary, versatile surgical lighting. Harmony vled Surgical Lighting System

Modifier Reference PAYMENT POLICY ID NUMBER: Original Effective Date: 05/14/10. Revised: 05/31/12 DESCRIPTION:

Model of Care for the Diabetic Foot

Ch. 138 CARDIAC CATHETERIZATION SERVICES CHAPTER 138. CARDIAC CATHETERIZATION SERVICES GENERAL PROVISIONS

Measuring Your Blood Pressure at Home. A Review of the Research for Adults

Crime Victims Compensation Program Mental Health Fees Effective January 1, 2014

FDA Issues Final Guidance on Mobile Medical Apps

Find your future in the history

Section Two: Arterial Pressure Monitoring

innovative solutions for your applications

EHR 101. A Guide to Successfully Implementing Electronic Health Records

DCCT and EDIC: The Diabetes Control and Complications Trial and Follow-up Study

Q1: Global risk assessment using PROCAM, SCORE, FRAMINGHAM or REYNOLDS ecc is sufficient YES NO NEED MORE DATA DISCUSS within Taskforce Your Comments

Centricity Group Management. Complex challenges demand proven solutions

Subclavian Steal Syndrome By Marta Thorup

GE Healthcare. Ready. Set. Acquire. CardioSoft diagnostic software

DASH PRO VARIABLE-ACUITY MONITORING. Connecting you to the right information no matter where patient care takes you. gemedical.com

Stuart B Black MD, FAAN Chief of Neurology Co-Medical Director: Neuroscience Center Baylor University Medical Center at Dallas

GUIDELINES FOR DOPPLER ULTRASOUND

CARESCAPE VC150 Vital Signs Monitor. Connecting intelligence and care.

AMBULATORY BLOOD PRESSURE MONITORING QUICK START GUIDE

Local Coverage Article: Endovascular Repair of Aortic Aneurysms (A53124)

Modifiers Q7, Q8, and Q9

huidige en toekomstige hemodynamische bewaking

3M Coban 2 Layer Compression Systems

Frequently Asked Questions about ICD-10

Vivid S6. Cardiovascular ultrasound system. imagination at work. GE Healthcare

Vascular Laboratory Fundamentals. Robert Mitchell MD, RPVI Duke University Medical Center 5/2/08

Carestream PACS. Make enterprise work flow

2016 PQRS OPTIONS FOR INDIVIDUAL MEASURES: REGISTRY ONLY

Disclaimer CODING 101 BOOT CAMP CODING SEMINAR FOR NEW PHYSICIANS

APPENDIX 1: INTERDISCIPLINARY APPROACH TO PREVENTION AND MANAGEMENT OF DIABETIC FOOT COMPLICATIONS

Leading the New Standards

Objectives: 1. Gain a basic understanding of the various terms, concepts, and abbreviations involved in coding and billing.

HAND-ARM VIBRATION SYNDROME ASSESSMENT TESTS

* Dignity Health. Success

CARDIAC CARE. Giving you every advantage

How To Use An Ultrasound For Medical Research

Extracranial Cerebrovascular Duplex Ultrasound Evaluation

GROUP MEDICARE SUPPLEMENT PLANS. S5753_081213_GB03_MN Internal Approval 08/13/2013

Solutions for Your Practice

Health Care 2.0: How Technology is Transforming Health Care

Physician Compare. Virtual Office Hour Session. January 22, 2015

ESC Guidelines on the diagnosis and treatment of peripheral artery diseases Lower extremity artery disease. Erich Minar Medical University Vienna

UGEO H60 PERFORMANCE IN STYLE

Modifiers. Hoda Henein, CHBME, CP President & CEO, Active Management A Practice Management Consulting and Billing Company

Transcription:

A Complete Range of Ankle Brachial Index (ABI) Systems for Peripheral Arterial Disease (P.A.D.) Detection

Diagnose Peripheral Arterial Disease (P.A.D.) Before it Becomes a Problem Versatile, Easy-to-Use and Accurate Calculation of ABI Wallach Surgical s portfolio of clinically proven medical solutions includes a complete line of vascular assessment systems for performing the Ankle Brachial Index (ABI) exam, for detecting and diagnosing P.A.D. P.A.D. is a serious illness affecting roughly 8 million Americans 1, typically over the age of 65, as well as individuals over the age of 50 who smoke or have diabetes 2. P.A.D. often goes undiagnosed and untreated, even though there are opportunities for earlier detection when patients are visiting their doctors in general practice, family practice, cardiology, vascular surgery, wound care or podiatry. Wallach s Summit Doppler line of vascular assessment systems and probes are designed to provide clinicians with maximum versatility, ease of use and accuracy for diagnosing patients with P.A.D. From our cost-effective LifeDop Series of handheld Dopplers to our more robust automated ABI systems, Wallach has a solution that will work for any clinical setting. 1 CDC Peripheral Arterial Disease Fact Sheet, July 26, 2013 2 Vascular Disease Foundation, 2012

Portable LifeDop Handheld Dopplers Easily Capture Waveforms Wallach Surgical offers the LifeDop 250 and the LifeDop 300, two cost-effective handheld Doppler options that easily locate vessels and detect blood flow. LifeDop dopplers are designed to be extremely durable, ensuring long-lasting operation. Both systems feature: Large heart rate displays Sensitive 8 MHZ bi-directional probes Two cuffs or four cuffs with aneroid Simple ABI reference documents and video The LifeDop 250 Dopplers measure systolic pressures that allow you to calculate ABI and diagnose P.A.D. The LifeDop 250 with four cuffs and aneroid also captures waveforms for reimbursement *. The LifeDop 300 unit has a convenient keypad for entering pressure data, and it quickly and automatically calculates ABI for you. The system includes a printer for capturing dual ankle waveforms for reimbursement, * four cuffs and aneroid, and all the necessary accessories needed for handling and storage. * Exam may meet CPT requirements as defined in the AMA CPT manual. Source: Current Procedural Terminology (CPT) is copyright 2013 American Medical Association. All rights reserved. No fee schedules, basic units, relative values, or related listings are included in CPT. The AMA assumes no liability for the data contained herein. Applicable FARS/DFARS restrictions apply to government use. LifeDop 250 ABI System LifeDop 300 ABI System 3

The Vista AVS and Vista ABI System for Greater Versatility and Accuracy The Advanced Vista AVS Conducts Single-level ABI, Seated ABI, TBI, and Segmental Studies The Vista AVS is a robust, highly versatile system ideal for conducting, interpreting and documenting ABI, TBI, and segmental studies with three modalities. An 8 MHz bi-directional Doppler probe can be used to obtain systolic pressure and ankle waveforms required for reimbursement *. Pulse Volume Recording (PVR) quickly captures ankle waveforms. A third modality, photoplethysmography (PPG) probe measures pressures for Toe Brachial Index (TBI) and segmental exams. The Vista AVS vascular system features: Segmental studies to help locate blockage or narrowing following single-level ABI exam Bi-directional Doppler, PVR and PPG modalities Automatic ABI, TBI, and segmental calculations Performs seated ABI exams for mobility impaired patients Obtains dual-ankle pressures, Posterior Tibial (PT), and Dorsalis Pedis (DP) arteries Software for reporting, annotating, storage, printing, and interfacing with EMR 9 cuffs with automatic inflation/deflation to speed up and customize segmental studies Optional 5 MHz bi-directional probe provides deeper penetration on larger patients The Vista AVS accommodates both standard and custom protocols. Easy-to-follow test sequences and handheld controller make navigating this system quick and simple. * Exam may meet CPT requirements as defined in the AMA CPT manual. Source: Current Procedural Terminology (CPT) is copyright 2013 American Medical Association. All rights reserved. No fee schedules, basic units, relative values, or related listings are included in CPT. The AMA assumes no liability for the data contained herein. Applicable FARS/DFARS restrictions apply to government use. Vista AVS and ABI 4

s Offer More Modalities The Easy-to-use Vista ABI Performs Single-level ABI, Seated ABI, and Optional TBI The Vista ABI system conducts single-level ABI exams and seated ABI exams * using the bi-directional Doppler probe or PVR. An optional PPG probe measures toe pressures for the TBI. The Vista ABI features: PVR and bi-directional Doppler modalities Reporting Software The Vista AVS includes PC software for full-page reporting, exam data storage, and integration with leading EMR systems. A download option is available for the Vista ABI. ABI Severity of Disease >1.4 Non-compressible 1.0-1.4 Normal 0.91-0.99 Borderline 0.41-0.90 Moderate to Mild 0.00-0.40 Severe ** Graphic waveform display with easy to follow test sequence 4 cuffs with automated inflation/deflation Optional PPG probe package Optional reporting software package Vista AVS and Vista ABI Advanced Features Doppler The bi-directional Doppler probe, long considered the gold standard for ABI exams used to obtain systolic pressures and waveforms. PVR PVRs can be used to obtain peripheral arterial waveforms with blood pressure cuffs. * Patent: US 20090099465A1 PPG PPG probe detects small changes in blood volume. Using a toe cuff, the PPG probe measures toe pressures in patients with noncompressible arteries. The PPG probe can be used to measure toe and brachial pressures for the TBI exam. PPG probes are also used to obtain toe pressures for segmental studies. ** 2011 ACCF/AHA Focused update of the Guideline for the Management of Patients with Peripheral Artery Disease (Updating the 2005 Guideline) 5

Vantage ABI Provides Higher Throughput for P.A.D. Screening The Vantage ABI offers screening capabilities, in as little as 3 minutes. The Vantage ABI completes a single level exam using Digital Fourier Oscillometry (DFO). Summit Doppler worked with researchers from the Cleveland Clinic to create their own unique DFO Algorithm *. Vantage ABI is available in two packages: as a standalone system or with built-in printer and stand. Other features include: Graphic display with touchscreen to easily navigate system USB for data transfer, storage, EMR interface Total of 4 cuffs: two 10 cm for ankles and two 12 cm for arms Vantage ABI * Patent: WO2012040428A2 6

Accessories Wallach offers a full line of accessories for each system. Please visit www.wallach.com for a full listing. Providing ABI studies can help your patients with early detection of P.A.D. To learn more, contact Wallach Surgical.

Wallach works for you. Wallach Surgical offers industry-leading medical systems and instruments, including colposcopes, cryosurgical and electrosurgical units, digital and Doppler imaging devices, and a broad range of instruments and disposables that keep practices and hospitals running safely and smoothly. Physicians have relied on our diverse product portfolio for more than 30 years. Moving forward, we are committed to expanding into new technologies, including our acquisition of Summit Doppler and our ongoing research and development efforts. Wallach Surgical Devices 95 Corporate Drive Trumbull, CT 06611 U.S.A. 1.800.243.2463 www.wallachsurgical.com Wallach Surgical Devices 82490 Rev. 5/14