PDU s Básicas Basic PDU s PDU Basiques. Efficient IT Solutions
|
|
- Basil Gray
- 8 years ago
- Views:
Transcription
1 Centros de datos / Datacentres / Centres de données PDU s Básicas Basic PDU s PDU Basiques
2 Regletas de conexión RX Series Regletas de conexión en formatos 19,1U o montaje vertical Zero U. Construcción modular, perfil de aluminio con acabado aislante y toma de tierra. Conectores en PA reforzado UL94V0 y escuadras de fijación reversibles en PC UL94V0. Conexionado interior sobre placa continúa de latón (Bus-bar) Cable de alimentación con distintas opciones de conectores. Conexión mediante Wieland GST-3A. Homologaciones: CE/VDE Acabado: Perfil de aluminio lacado color natural. Bases y escuadras fijación negro similar a RAL9004. Entrega: unitaria en caja de cartón. Power distribution units in 19, 1U format or vertical assembly Zero U's Modular construction, manufactured in insulated aluminium profile. Connections bases in reinforced PA UL94V0 and reversible brackets in PC UL94V0 Internal connections on brass Bus-bar. Power cable with different connector options. Connections through Wieland GST-3A connectors. Homologations: CE/VDE Finish: Aluminium profile in natural colour. Connectors and brackets in black similar to RAL9004 Delivery: 1 unit packed in a cardboard box. Réglettes de connexion 1U, 19'' ou en montage vertical Zero U. Construction modulaire en profilé d'aluminium isolant. Connecteurs en PA UL94V0 renforcé et équerres de fixation en PC UL94V0 Connexions intérieures sur plaque continue en laiton (Bus-bar). Câble d'alimentation avec différentes options de connecteurs. Connexion a travers de Wieland GST-3A. Homologations : CE / VDE Finition : Profilé d'aluminium naturel, connecteurs et équerres de fixation coloris noir similaire à RAL Emballage : Unitaire en carton individuel. F (SCHUKO) DIN A - 250V RX - SCHUKO DIN * 1 Schuko 8 Green Led indicator 2m x 1,5 mm2 Schuko/UTE DIN * 1 Schuko 8 Green Led indicator Check table code Wieland GST-3P * 1 Schuko 8 ON/OFF light switch 2m x 1,5 mm2 Schuko/UTE DIN * 1 Schuko 6 Thermal Circuit Breaker 2m x 1,5 mm2 Schuko/UTE DIN49441
3 * 1 Schuko 6 Ammeter Check table code Wieland GST-3P * 1 Red Schuko 8 Green Led indicator 2m x 1,5 mm2 IEC320-C * 1 Schuko 6 RFI Filter + ON/OFF light switch 2m x 1,5 mm2 Schuko/UTE DIN * 1 Schuko 6 Surge Protector 2m x 1,5 mm2 Schuko/UTE DIN Schuko 16 Green Led indicator and overload 2m x 1,5 mm2 Schuko/UTE DIN Schuko 16 Green Led indicator and overload Check table code Wieland GST-3P Schuko 16 Ammeter and overload Check table code Wieland GST-3P
4 RX - IEC320 C13/14 C13 (IEC 320) 10A - 250V * 1 IEC320-C13 12 Led and fuse 2m x 1,5 mm2 IEC320-C * 1 IEC320-C13 12 Led and fuse Check table code Wieland GST-3P * 1 IEC320-C13 8 Ammeter Check table code Wieland GST-3P IEC320-C13 24 Led and overload Check table code Wieland GST-3P IEC320-C13 24 Ammeter Check table code Wieland GST-3P IEC320-C13/C19 18C13+4C19 Ammeter and overload Check table code Wieland GST-3P
5 RX - UTE (France-Belgium) E (UTE) B, F, L * 1 Schuko 8 Green Led indicator 2m x 1,5 mm2 Schuko/UTE DIN * 1 Schuko 8 Green Led indicator Check table code Wieland GST-3P * 1 Schuko 8 ON/OFF light switch 2m x 1,5 mm2 Schuko/UTE DIN * 1 Schuko 6 Thermal Circuit Breaker 2m x 1,5 mm2 Schuko/UTE DIN * 1 Schuko 6 Ammeter Check table code Wieland GST-3P * 1 Red Schuko 8 Green Led indicator 2m x 1,5 mm2 IEC320-C * 1 Schuko 6 Surge Protector 2m x 1,5 mm2 Schuko/UTE DIN49441
6 Schuko 16 Green Led indicator and overload 2m x 2,5 mm2 Schuko/UTE DIN Schuko 16 Green Led indicator and overload Check table code Wieland GST-3P Schuko 16 Ammeter and overload Check table code Wieland GST-3P RX - IEC320 C19/20 C19 (IEC 320) * 1 IEC320-C19 8 Led Check table code Wieland GST-3P * 1 IEC320-C19 5 Ammeter Check table code Wieland GST-3P
7 RX - 32 Amp 1 Phase * 1 IEC320-C19 8(4+4) 2 Branch circuits 2 ammetesr 2 fuses 3m x 4 mm2 IEC A * 1 Schuko 8(4+4) 2 Branch circuits 2 ammeters 2 fuses 3m x 4 mm2 IEC A IEC320-C13 12(6+6) 2 Branch circuits 2 ammeters 2 fuses 3m x 4 mm2 IEC A IEC320-C13 12(6+6) 2 Branch circuits 2 thermal bipole circuit breakers 3m x 4 mm2 IEC A Schuko 12(6+6) 2 Branch circuits 2 thermal bipole circuit breakers 3m x 4 mm2 IEC A IEC320C13-C19 24(12+12)C13 + 4(2+2)C19 2 Branch circuits 2 ammetesr 2 fuses 3mx4 mm2 IEC A
8 RX - 16A 3 Phases * 1 Schuko 6(2+2+2) 3 Branch circuits 3 thermal bipole circuit breakers and leds 3m x 4 mm2 IEC A * 1 IEC320-C19 6(2+2+2) 3 Branch circuits 3 thermal bipole circuit breakers and leds 3m x 4 mm2 IEC A * 1 Schuko 6(2+2+2) 3 Branch circuits 3 ammeters, fuses and leds 3m x 4 mm2 IEC A * 1 IEC320-C19 6(2+2+2) 3 Branch circuits 3 ammeters, fuses and leds 3m x 4 mm2 IEC A IEC320-C13/C19 30( )C13+6(2+2+2)C19 3 Branch circuits 3 ammeters, fuses and leds 3m x 4 mm2 IEC A
9 RX - 32A 3 Phases * 1 Schuko 6(2+2+2) 3 Branch circuits 3 thermal bipole circuit breakers and leds 3m x 4 mm2 IEC A * 1 IEC320-C19 6(2+2+2) 3 Branch circuits 3 thermal bipole circuit breakers and leds 3m x 4 mm2 IEC A * 1 Schuko 6(2+2+2) 3 Branch circuits 3 ammeters, fuses and leds 3m x 4 mm2 IEC A * 1 IEC320-C19 6(2+2+2) 3 Branch circuits 3 ammeters, fuses and leds 3m x 4 mm2 IEC A Schuko 18(6+6+6) 3 Branch circuits and leds 3m x 4 mm2 IEC A
10 IEC320-C13/C19 30( )C13+6(2+2+2)C19 3 Branch circuits 3 ammeters, fuses and leds 3m x 4 mm2 IEC A G (BS 1363) RX-BS(UK) * 1 UK 7 Green led indicator 2m x 1,5mm2 BS UK UK 16 Green led and overload 2m x 2,5mm2 BS UK * 1 UK 5 Ammeter 2m x 1,5mm2 BS UK * 1 UK 6 ON/OFF light switch 2m x 1,5mm2 BS UK B (NEMA 5-15) 10/16A - 120V RX - NEMA (US) * 1 NEMA 5-20R 10 Led indicator and overload 10 feet 12/3 NEMA 5-20P NEMA 5-20R 12 Led indicator and overload 10 feet 12/3 NEMA 5-20P
11 * 1 NEMA 5-20R 8 Ammeter + Overload 10 feet 12/3 NEMA 5-20P NEMA 5-20R 12 Ammeter + Overload 10 feet 12/3 NEMA 5-20P RX HOUSEHOLD / IT (Denmark) K (Household) * 1 Household 8 ON/OFF light switch 3m x 1,5 mm2 Household * 1 Household 8 Green led indicator 3m x 1,5 mm2 Household Household 12 ON/OFF light switch 3m x 1,5 mm2 Household * 1 Household 8 ON/OFF light switch 10m x 1,5 mm2 Household Household 12 ON/OFF light switch 10m x 1,5 mm2 Household DK 2-5A (IT) * 1 IT 8 Green led indicator 3m x 1,5 mm2 IT IT 12 Green led indicator 3m x 1,5 mm2 IT * 1 IT 8 Green led indicator 10m x 1,5 mm2 IT IT 12 Green led indicator 10m x 1,5 mm2 IT
12 RX - POWER CABLES Conexión rápida y segura a través de conector Wieland GST-3A. Longitud de cable 3 metros. Fast and secure connection with Wieland GST-3A. 3 meters long cable. Connexion rapide et sécurisée par connecteur Wieland GST-3A. Longueur câble :3 mètres. Code Cable Connector m x 1,5 mm2 Schuko/UTE to Wieland GST-3P Code Cable Connector m x 1,5 mm2 IEC320-C14 to Wieland GST-3P Code Cable Connector m x 1,5 mm2 IEC320-C20 to Wieland GST-3P Code Cable Connector m x 1,5 mm2 Bs1363 (UK) to Wieland GST-3P Code Cable Connector m x 1,5 mm2 CETAC16A s1 phase to Wieland GST-3P B (NEMA 5-15) 10/16A - 120V DK 2-5A (IT) K (Household) Danish Code Cable Connector m x 1,5 mm2 NEMA 5-15R (US) to Wieland GST-3P m x 1,5 mm2 IT (DK) to Wieland GST-3P m x 1,5 mm2 Household (DK) to Wieland GST-3P
SURGE PROTECTIVE DEVICES
SURGE PROTECTIVE DEVICES 1. INTRODUCTION In order to ensure safety of people, protection of equipment and, to a certain extent, continuity of supply, insulation co-ordination aims at reducing the likelihood
More informationIEC 309 INTERLOCKS NORTH AMERICAN
IEC 309 INTERLOCKS NORTH AMERICAN SWITCH VERSION with MCB (Circuit Breakers) 20, 30, 60 Amp NEMA 4X Watertight (IP67) Drawing A (See Drawing on Specification Page) 20, 30, 60 Amp Spashproof (IP44) Drawing
More information> CABLE 3 MM / 3 MM CABLE COMPONENTS
C3100 KIT POUR FIXATION SOL-PLAFOND (4 MÈTRES) - Fixation haute Ø 18,5 mm - Câble en acier inoxydable L. 4 m - Fixation basse avec tendeur (Clé Allen et vis fournies avec le Kit) FLOOR / CEILING FIXING
More informationLINEA 120 FIXED Colour White = MW Matte White RAL 9016 Colour Black = BL Matte Black RAL 9005 Beam Angle 60 EN60598 / EN62031 / EN62471.
LINEA 120 FIXED ECO solution Ø 180 mm Specifications LINEA 120 FIXED Colour White = MW Matte White RAL 9016 Colour Black = BL Matte Black RAL 9005 Beam Angle 60 Fixture Material Diecast Aluminium Environment/Applications
More informationSOHOline and SOHO Slimline The SOHOline and SOHO Slimline offer a modular, sturdy and compact design
SOHOline and SOHO Slimline The SOHOline and SOHO Slimline offer a modular, sturdy and compact design Ideal installation for; Offices Branch Offices Schools Computer Aided Classes Government Offices Hotels
More informationAhead in power distribution
Ahead in power distribution DEDICATED SOLUTIONS FOR POWER DISTRIBUTION AND MONITORING IN DATA CENTERS 2 A tradition in innovation AMBACHTSSTRAAT 12, 3861 RH NIJKERK, THE NETHERLANDS I T +31 33 245 23 60
More informationACABADOS DE PLACA PLATE FINISHES
ACABADOS DE PLACA PLATE FINISHES STAINLESS STEEL ACERO INOXIDABLE BLACK ALUMINIUM ALUMINIO NEGRO SILVER ALUMINIUM ALUMINIO PLATA CHAMPAGNE ALUMINIUM ALUMINIO CAVA WHITE CORIAN CORIAN BLANCO GRAPHITE BRASS
More information32:(5#5$7,1* 4833#USP283#+] 4;33#USP293#+] 3ULPH 113 kva, 90 kw 124 kva, 99 kw 6WDQGE\ 114 kva, 91 kw 125 kva, 100 kw
,1'8675,$/#*(16(7 6HULHV#'9#448 32:(5#5$7,1* 4833#USP283#+] 4;33#USP293#+] 3ULPH 113 kva, 90 kw 124 kva, 99 kw 6WDQGE\ 114 kva, 91 kw 125 kva, 100 kw Generator set consisting of engine and alternator mounted
More informationADM1TE 5/30A DIN rail single phase two wire energy meter
ADMTE 5/30A DIN rail single phase two wire energy meter. Safety instruction.2 Foreword.3 Performance criteria.4 Specifications.5 Basic errors.6 Description.7 Dimensions.8 Installation.9 Operating.0 Troubleshooting.
More informationT Connectors - Raccords T. X Connectors - Raccords X. Wash locker - Anillo de fijación. End cap - Tapón terminal. Protection cap - Tapón de protección
L Connectors - Eles L BAT/21762 : L connectors 6/0 / Eles L 6/0 BAT/19814 : L connectors 6/6 / Eles L 6/6 BAT/16293 : L connectors 10/6 / Eles L 10/6 BAT/16297 : L connectors 10/10 / Eles L 10/10 T Connectors
More informationfeatures características wall mount cabinets PRESTO range has been developed for networking solutions. Its
presto wall mount cabinets PRESTO range has been developed for networking solutions. Its smart design allows an easy installation of equipment, and a fast and simple wall mounting. La gama de murales PRESTO
More informationINTELLIGENT & BASIC POWER DISTRIBUTION UNITS (PDU)
version: 7-05-0 CONTEG DATASHEET COMPLEMENTARY SYSTEMS INTELLIGENT & BASIC POWER DISTRIBUTION UNITS (PDU) CONTEG, spol. s r.o. Czech Republic Headquarters: Na Vítězné pláni 79/4 40 00 Prague 4 Tel.: +40
More informationIEC Connectors. Introduction
Introduction IEC Connectors A full range of quality mains rated inlets, outlets and connectors conforming to IEC and EN 60320 specifications carrying UL, CSA, VDE and other approvals. With electrical ratings
More informationEaton epdu. Intelligent and flexible power distribution
Eaton epdu Intelligent and flexible power distribution Introduction and overview With today s changing technology, increasing power demands and the need for reliability, data centre professionals require
More informationRenewable energy. Inverters - Socomec G-1. Load break switches (Isolators) - Socomec G-2. Fuses - df G-3. Fuse bases.
G Product page Inverters - Socomec G-1 Load break switches (Isolators) - Socomec G-2 Fuses - df G-3 Fuse bases Surge protection - df G-3 - Wohner G-5 - CPT G-4 - Dehn G-5 Connectors - Wieland G-6 Cable
More informationLevelOne IFE-0500 4-Port PoE + 1-Port TP Industrial Fast Ethernet Switch User Manual
LevelOne IFE-0500 4-Port PoE + 1-Port TP Industrial Fast Ethernet Switch User Manual Ver. 1.0.0-0711 1 FCC Warning This Equipment has been tested and found to comply with the limits for a Class-A digital
More informationDRM75A 230V 20/100A DIN rail single phase two wire energy meter
DRM75A 230V 20/100A DIN rail single phase two wire energy meter 1.1 Safety instruction 1.2 Foreword 1.3 Performance criteria 1.4 Specifications 1.5 Basic errors 1.6 Description 1.7 Dimensions 1.8 Installation
More informationELEKTROTEHNI KO PODJETJE Leskoπkova cesta 12, 1000 Ljubljana, SLOVENIA
MRO Modularne Razdelilne Omare d.o.o. ELEKTROTEHNI KO PODJETJE Leskoπkova cesta 2, 000 Ljubljana, LOVENIA MC GENERAL When to use? MC - modular switchgear cabinets are type-tested, factory built switchgears,
More informationPower Supply Specifications
APPENDIXA This appendix describes the Catalyst 6500 series power supplies and provides their specifications. This appendix contains the following sections: Power Supply Compatibility Matrix, page A-2 950
More informationAdaptive power distribution in the data center
AC power supply for Business-Critical Continuity Adaptive power distribution in the data center A step towards the future with Emerson Network Power Contents Server rack power distribution Rack PDUs overview...
More information3K Load-Break Switches The Program for Safety and Performance. sentric
3K Load-Break Switches The Program for Safety and Performance sentric Whether for reliable switching and isolation under load, or for protection against overload or short-circuits our 3K range of load-break
More informationDual Battery Harnesses
Dual Battery Harnesses D122L/D122 en Installation Instructions Dual Battery Harnesses Introduction en 3 1 Introduction The D122L and D122 Dual Battery Harnesses protect the installer and the battery with
More information46120-F0 Solar Energy Training System
46120-F0 Solar Energy Training System LabVolt Series Datasheet Festo Didactic en 120 V - 60 Hz 06/2016 Table of Contents General Description 2 List of Equipment 2 List of Manuals 3 Table of Contents of
More information06 / 2003. Optional components. MAXDATA PLATINUM Server-Rack PLATINUM. [Product Guide] www.maxdata.de
D Positioning Key-Features Specifications Optional components MAXDATA PLATINUM Server-Rack PLATINUM [Product Guide] www.maxdata.de Positioning Description Server-Racks with 41U, 37U and 23U Highlights
More informationSURFOX 304 MIG & TIG 54-D 314 (120V) & 54-D 334 (230V) MARCH 2015 1.48-R 461 5. 48-R 462 2. 48-R 313 3. 48-K 419 4. 48-S 114 6. 48-S 128 7.
A 1.48-R 461 5. 48-R 462 2. 48-R 313 6. 48-S 128 3. 48-K 419 4. 48-S 114 7. 48-R 314 9.48-R 463 8. 48-R 136 10. 48-R 105 11. 48-R 254 12. 48-R 109 13. 48-R 321 14. 48-R 214 B 15. 48-K 420 16. 48-S 228
More informationMEDIUM VOLTAGE CE-BF SWITCHBOARDS. UP TO 40.5 kv. CE - BF - C - en - REV.00 2012.4
CE - BF - C - en - REV.00 2012.4 APPLICATION CE-BF Switchbords up to 40.5 kv are designed for use in public and industrial distribution system up to 40,5KV for the operation and protection of lines, transformers,
More informationTable of Contents. 1. Introduction...1. 2. PDU Package...2. 3. Function...3. 4. Installation...5. 5. Web Interface...7
PDU User Manual Table of Contents 1. Introduction...1 2. PDU Package...2 3. Function...3 4. Installation...5 5. Web Interface...7 1. Introduction The PDU is an Internet ready device designed and is equipped
More informationmpm DIN 43650 CONNECTORS
mpm DIN 43650 CONNECTORS : Highest quality, robust connectors for hydraulic and pneumatic electromechanical devices Broad offering of DIN 43650 connectors and devices Combined Brad and mpm cordsets : Provide
More informationEdition Perfect combination ratiopacpro Electronic P Edition kaging www clear order..biz information in the catalogue
ratiopacpro Overview... 0 Cabinets... 1 Y Desk-top cases Y Wall mounted cases... 2 Accessories for cabinets and wall mounted cases... 3 Climate control... 4 Desk-top cases... 5 06800002 Subracks/ 19" chassis...
More informationData Center Power Overload Protection: Circuit breakers and branch circuit protection for data centers
Data Center Power Overload Protection: Circuit breakers and branch circuit protection for data centers 2009, Raritan Inc. Introduction Over the past few years, average power consumption per server has
More informationNew XUY roller sensors
Do you want to simplify the sensor integration in your conveyor systems? New XUY roller sensors for packet, boxes, letters on roller conveyors. Telemecanique Sensor s OsiSense TM XUY photoelectric sensors
More information5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual
5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual Content Overview... 1 Introduction... 1 Features... 3 Packing List... 4 Safety Precaution... 4 Hardware Description... 5 Front Panel...
More information3.1.1 Full Type Tests & Routine Tests according to Clause 8 2 & 8 3. 4.0 Instructions For Installation, Operation & Maintenance
SPECIFICATION FOR LOW VOLTAGE SWITCHBOARD SEN I N D E X Description 10 STANDARD TECHNICAL REQUIREMENTS 11 Standards 12 General Operating Conditions 13 General Description Of Switchboard 131 Structure 132
More informationIntersection Preassembled 19-inch Rack
Intersection Preassembled 19-inch Rack The intersection preassembled 19-inch rack comes fully assembled, wired and ready to be installed in a server rack. The rack provides communications, power conversion
More informationMagnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2...
Magnetic and Hydraulic-Magnetic Circuit Breaker 840-G2... Description Single, two and three pole magnetic circuit breakers with trip-free mechanism and push/pull on/off manual actuation. A choice of fast
More informationElectromagnetic pump designation GOTEC
Electromagnetic pump designation GOTEC E T S 21 - E : In beginning of the designation for all pumps based on the Electromagnetic principle. 1 T : means the complete square motor (coil + metallic frame
More informationDRY TYPE TRANSFORMER
PRODUCT LEAFLET DRY TYPE TRANSFORMER Single-phase, three-single, three-two and three-phase transformers 1.1 kv to 7.2 kv classes 1 60 40152-13/09/2011 Dry Type Transformers Transformers meant to be installed
More informationMICROSENS. Central 48 V DC Power Supplies for PoE-Components. Description. Features
Central 48 V DC Power Supplies for PoE-Components MICROSENS Description Active network equipment which is supporting the Power-over-Ethernet functions, typically requires a powerful 48 V DC power supply.
More informationComparison of NEMA and IEC schematic diagrams
Cross-Reference MZ081001EN Comparison of NEMA and IEC schematic diagrams General With the increasing emphasis on globalization, many industries are now looking to all parts of the world to produce, market,
More informationKNX Interface. User Manual PM00A00IRI
KNX Interface User Manual PM00A00IRI 1/9 1. Index 1. Index...2 2. Preface... 3 2.1. Overview... 3 2.2. System description... 3 2.3. Application programs... 3 2.4. Documentation... 3 3. Mechanical reference...
More information1978-83 Malibu 1978-87 Monte Carlo 1978-87 El Camino
Important facts about this kit. 1. The dash panel used in this picture is used by permission of Covan's Classic. 2. This kit requires some modification to your original under dash wiring harness. It is
More informationCapteur température et humidité pour HVAC
Capteur température et humidité pour HVAC oct-13 Type R 590 Type R 591 Cable Pvc / Pvc Cable Silicone / Silicone Sonde de température Pt100, Pt1000, Ni1000, KTY, NTC, autres sur demande Classe B ou A Raccordement
More informationLow Voltage Fuses For Motor Protection
Code Requirements The NEC or CEC requires that motor branch circuits be protected against overloads and short circuits. Overload protection may be provided by fuses, overload relays or motor thermal protectors.
More informationPower Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1
Power Supply Unit, Primary Switched, Narrow Design MINI POWER provides: Extra narrow design with widths of 22.5 mm, 45 mm, and 67.5 mm (0.886, 1.772, and 2.657 in.) Global use due to a wide-range input
More information400 Series Buccaneer BUCCANEER POWER. bulgin
bulgin BUCCANEER FOR POWER Contact Retainer Sealing Gasket O Ring Contacts Locking Ring Retaining Nut Panel Body Contacts Contact Carrier O Ring Main Body Cable Gland Collet Gland Nut Sealed to IP68 when
More informationNetworking Cabinets and Enclosures
Networking Cabinets and Enclosures Excel is a world-class premium performing end-to-end infrastructure solution - designed, manufactured, supported and delivered - without compromise. Networking Cabinets
More informationDistributing Power to Blade Servers
Distributing Power to Blade Servers Ten steps to selecting the optimal power distribution design With the growth in blade servers with dual or triple power supplies, a single rack of equipment can easily
More informationROLLING STOCK CABLES
CABLES UNIPOLAIRES EXTRA-SOUPLE SANS GAINE UNSHEATHED SINGLE CORE CABLES WITH EXTRA-FLEXIBLE CONDUCTOR CARACTERISTIQUES DU CABLE CABLE CHARACTERISTICS - 40 C Bon Résistant à Bon / Good Tenue au feu Zero
More informationL304 LED PUSHBUTTON SWITCH / DISPLAY INDICATOR INDICATEUR LUMINEUX A LED / BOUTON POUSSOIR
MECHANICAL CHARACTERISTICS CARACTERISTIQUES MECANIQUE PRINCIPAL TECHNICAL CHARACTERISTICS CARACTERISTIQUES TECHNIQUES PRINCIPALES 3 possible versions - Single indicator - Momentary action pushbutton (1
More informationLED RGB. Strip LED Connection System. 9er LED RGB Schiene komplett mit einem isolierenden und durchsichtigen Kunststoffprofil.
ED RB Strip ED Connection System Sistema modulare a connessioni rapide per barre e faretti ED. Modular system with quick-connect connections for strips and ED spotlights. 9er ED RB Schiene komplett mit
More informationMADE IN ITALY 200 max
PLANA 2 PLANA SOSPENSIONE Marco Spada 2012 L55035-01 trasparente transparent 1,9 21 15 2,85 1,5 200 max LED bianco caldo warm white LED 12 LED x 2W (V in 230V) 80 Struttura in metacrilato. Modulo LED con
More informationHome & Office Solutions
CLASSIC (B-YAC-A-***) 2 seperate power connectors for main and UPS power sockets. The side panels allow up to 8 cable connection. Could be mounted vertically or horizontally with connection accessories.
More informationClimasys Thermal Management System. Schneider Electric Universal Enclosures 2009
Climasys Thermal Management System Schneider Electric Universal Enclosures 2009 Schneider Electric Universal Enclosures The specialist in sealed equipment What is the mission of Schneider Electric Universal
More informationED1259R5 Updated April 2011 For latest specs visit www.legrand.us/wiremold
Rack Power Distribution Solutions for IT/Network Environments Wiremold Power Commander Power Distribution Units offer comprehensive power distribution solutions for IT environments from networking solutions
More informationPower distribution in data centres
Power distribution in data centres by Manuel Lotz / Matthias Ribbe White Paper 09 Copyright 2008 All rights reserved. Rittal GmbH & Co. KG Auf dem Stützelberg D-35745 Herborn Phone +49 (0)2772 505-0 Fax
More informationFakra. Coaxial connectors. DC 6 GHz
C-Blue D-Bordeaux GPS application GSM/Mobil Phone The FAKRA (Automobile Expert Group) has therefore defined a standardised connector system for the various communication applications in cars. Our FAKRA-compliant
More informationHow To Build A Low Voltage Capacitor Lvcp
Low Voltage Capacitor LVCP The new choice for Power Factor Correction LVCP : the new choice for Power Factor Correction The LVCP is a compact and powerful capacitor. It offers high modularity, unmatched
More informationTrade of Electrician. Three-phase Distribution Boards And Socket Circuits
Trade of Electrician Standards Based Apprenticeship Three-phase Distribution Boards And Socket Circuits Phase 2 Module No. 2.3 Unit No. 2.3.2 COURSE NOTES Created by Charlie Walsh - Athlone TC Revision
More informationCurrent distribution Comb busbars for Declic and SFT residential devices
Current distribution Comb busbars for Declic and SFT residential devices Comb busbar, for connecting 26 x 9 mm modules, consisting of two insulated bars to supply 1P + N devices (Declic, SFT, etc.). Due
More informationDraper Low Voltage, Remote Control, Serial and Network Wiring Guide
Draper Low Voltage, Remote Control, Serial and Network Wiring Guide Copyright 2007 Draper Inc. Form LV-RC-Serial-Network_Wiring07 Print ed in U.S.A. Draper Low Voltage, Remote Control, Serial and Network
More informationNUMERIC SIGN SP2-6XX / 180mm. Presentation
NUMERIC SIGN SP2-6XX / 180mm Presentation 1 CONTENTS 1 CONTENTS... 2 2 PRESENTATION... 3 3 DIMENSIONS... 4 4 NUMERIC TYPES... 5 4.1 3 DIGITS, SP2-630/180 5 4.2 4 DIGITS, SP2-640/180 (PREFERRED TYPE) 5
More information2013 / Listino / Price List / Preisliste / Liste de Prix / Lista Precios
Heating solutions 2013 / Listino / Price List / Preisliste / Liste de Prix / Lista Precios Composizioni Versions Kompositionen Compositions composiciones Attacco corto singolo a parete / Single Short
More informationTX OPEN RS232/485 module
s 8 185 8185P01 TX-I/O ; DESIGO OPEN TX OPEN RS/485 module for integrating third-party systems and devices to DESIGO (V4 or higher) TXI1.OPEN Platform to integrate third-party systems and devices to the
More informationMSNswitch: 1. Automatically Power-Cycle Unresponsive Network Devices 2. Watch-Dog for Network Devices
MSNswitch: 1. Automatically Power-Cycle Unresponsive Network Devices 2. Watch-Dog for Network Devices UIS-323f (Schuko) UIS-323g (UK) UIS-323k (Denmark) UIS-323e (French) Auto power-cycle outlet when internet
More informationRelative pressure transmitter type 520
Relative pressure transmitter type 520 Pressure range -1... 9 bar / 0... 2.5 1000 bar The compact type 520 pressure transmitter is based upon the Huba Control developed thick film technology where the
More informationThermal-Magnetic Circuit Breaker 3120-...-M1-..
Thermal-Magnetic Circuit Breaker -...-M-.. Description Single or two pole rocker switch/thermal-magnetic circuit breaker with trip-free mechanism (S-type TM CBE to EN 34). The addition of a magnetic tripping
More informationWING TABURETE. WEIGHT PESO 5,5 Kg. INCLUDE INCLUYE
WING TABURETE for indoor and outdoor use. Available with different finishes. WEIGHT PESO 5,5 Kg. RGB LED: Colour changes of remote control. Non-slipping feet. LED RGB: Mando a distancia para cambio de
More informationDEK-REL- 24/1/SEN. Extract from the online catalog. Order No.: 2964050
Extract from the online catalog DEK-REL- 24/1/SEN Order No.: 2964050 Relay terminal block for sensor, with soldered-in miniature relays, contact (AgNi+Au): small to medium loads, 1 N/O contact, input voltage
More informationMedium Voltage Products. ZN1 12 kv arc-proof air-insulated switchgear for primary distribution
Medium Voltage Products ZN1 12 kv arc-proof air-insulated switchgear for primary distribution ZN1 an innovative switchgear for power distribution requirements ABB ZN1 primary distribution switchgear is
More informationEmerson Network Power Rack PDU Solutions Rack Power Distribution For Critical IT Equipment. AC Power For Business-Critical Continuity
Emerson Network Power Rack PDU Solutions Rack Power Distribution For Critical IT Equipment AC Power For Business-Critical Continuity Enhanced Performance And Management Of Dynamic IT Spaces IT space is
More informationWE-350 Series ¼ Turn Electric Actuator
WE-350 Series ¼ Turn Electric Actuator Operation and Installation Manual Pg 1 (Rev. 020113) Table of Contents 1.0 General 1.1 Pre-Installation Inspection 1.2 Storage 1.3 Features & General Information
More informationLOXONE 12 Channel Amplifier
LOXONE 12 Channel Amplifier Item no.: 200110 Thank you for purchasing the Loxone Twelve Channel Amplifier. The versatility of the Amplifier makes it the perfect choice for almost every type of custom multi-room
More informationThe all-in-one residential network. Delta 8. Access to TV, radio, phone and data in every room
The all-in-one residential network Delta 8 Access to TV, radio, phone and data in every room A Delta 8 home.is a home without visible trailing cables, or leads between different rooms enabling access to
More informationBB800 Off-Grid Solar System
BB800 Off-Grid Solar System KEY PRODUCT FEATURES Control Box & Charge Controller 1000W of Solar Panels 4x200Ah of SLA Batteries in series 2KW Inverter Output Power Solar Panel & Battery Mounting Our entry
More informationAirline. small air handlers and extract fan units. VES Airline part of a complete range of innovative, flexible products from the HVAC experts
Lo w p r o f i l e small air handlers and extract fan units Duties to 0.55m 3 /sec Available with the Electroline fitted control panel Ceiling void friendly - unit heights from 190mm to 350mm Airline VES
More informationPower Distribution Considerations for Data Center Racks
Power Distribution Considerations for Data Center Racks Power Distribution Considerations for Data Center Racks Table of Contents 3 Overview 4 At what voltage do you run all the IT equipment? 4 What electrical
More informationLaser diffuse reflection light scanner with background suppression. Dimensioned drawing
Specifications and description HRTL 3B Laser diffuse reflection light scanner with background suppression Dimensioned drawing We reserve the right to make changes DS_HRTL3B_en.fm en 01-2010/12 50114049
More informationIT infrastructure Efficiency-boosting solutions. nextlevel. for data centre
IT infrastructure Efficiency-boosting solutions nextlevel for data centre 2 Rittal IT infrastructure The whole is more than the sum of its parts. The same is true of Rittal The System. With this in mind,
More informationR.C.C.B. s two-pole LEXIC
87045 LIMOGES Cedex Telephone : (+33) 05 55 06 87 87 Fax : (+ 33) 05 55 06 88 88 R.C.C.B. s two-pole LEXIC 089 06/09/10/11/12/15/16/17/18/ 27/28/29/30/35, CONTENTS PAGES 1. Electrical and mechanical characteristics...
More informationPowerFlex 700S and 700H Frame 12 DC Bus Connector Kit
PowerFlex 700S and 700H Frame 12 DC Bus Connector Kit Installation Instructions This document provides instructions for the installation of a DC bus connector kit for PowerFlex 700S and 700H frame 12 drives
More informationRack Power Distribution Unit For Critical IT Equipment
AC Power for Business-Critical Continuity Rack Power Distribution Unit For Critical IT Equipment One Move Ahead With Emerson Network Power Emerson Network Power, a division of Emerson, is a global company
More informationBLADE S-MAX Cabinet for Blade Server
Cabinet for Blade Server 1 2 Overview Material specification Corner verticals: 1.5 mm steel End frames: 1.5 mm steel Panel mounts: 2.0 mm steel Panel mount supports: 1.5 mm steel Side panels, door and
More informationCertification of Plastic Materials
VDE Testing and Certification Institute Merianstraße 28 D-63069 Offenbach A Certification of Plastic Materials Glow-Wire Flammability Index GWFI Glow-Wire Ignition Temperature GWIT Comparative Tracking
More informationFASTON Printed Circuit Board Tabs and Receptacles
FSTON Tabs and eceptacles Product Facts Full line of PC tabs and receptacles Straight and right-angle tabs available in 50, 87 and 0 series eceptacles produced in 50/05 x 03 or 05 Standard or low insertion
More informationOur brand POWER DYNAMIC PASSION COMMITMENT CREATIVITY. A strong brand for strong products: 8PU Premium. MV Energy
Our brand A strong brand for strong products: The ENERGOLINE brand represents our product portfolio of INDUSTRIAL SWITCHGEAR SYSTEMS. Our products are characterized by a high degree of safety, flexibility
More informationTORKEL 820 Battery Load Unit
TORKEL 820 Lightweight Expandable system Rugged and reliable for field use Test without disconnecting the battery from the equipment it serves Description During a power outage, crucial telecommunication
More informationGUIDE TO LV SWITCHGEAR & FORMS OF SEPARATION
GUIDE TO LV SWITCHGEAR & FORMS OF SEPARATION CONTENTS INDEX...PAGE # PRODUCT EXAMPLES Mobile Battery Charging Unit... 3 PRODUCT EXAMPLES Form 4 Type 5 PDU - C/W Isolating Transformer... 3 PRODUCT EXAMPLES
More information12VDC MAGNETIC LED DIMMABLE POWER SUPPLIES SPEC SHEET DIGEST
12VDC MAGNETIC ED DIMMABE POER SUPPIES SPEC SEET DIGEST TM-30-DIM TM-50-DIM T-60-DIM TM100-DIM TM200-DIM TM300-DIM iring Diagram for TM-50-DIM and TM-100-DIM ED 12VDC MAGNETIC DIMMABE 30 POER SUPPY Smallest
More informationBouton Poussoir à Voyant 250V / 16A X Push Button With Light 250V / 16A X. Voyant Lumineux Indicator Lamp
Bouton Poussoir à Voyant 250V / 16A X Push Button With Light 250V / 16A X 45B05L 45905L 45305L 45B05L 45905L 45305L Bouton Poussoir à Voyant 1 module Blanc Push Button With Light 1 module White Bouton
More informationRISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER
Application : The RISH CON - Hz transducer is used for frequency measurement. The output signal is proportional to measured frequency and is either load independent DC Current or load independent DC Voltage.
More information1492 Marker Cards & Marking Systems
1492 Marker Cards & Marking Systems Clearmark Printer with Ink Cartridges Marker Cards Rockwell Automation offers marking solutions for your industrial equipment, wires and terminal blocks for both Allen-Bradley
More informationEspresso coffee grinder
Espresso coffee grinder 40A Espresso grinder 40A (Grey model) Internationally patented models L o n g l i f e, d e s i g n a n d s i l e n c e Silent espresso Fresh ground coffee gives the best espresso
More informationSTEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: 2868567. DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase
Extract from the online catalog STEP-PS/1AC/12DC/1.5 Order No.: 2868567 DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase Commercial data EAN 4046356292924 Pack 1 pcs. Customs tariff
More informationMore protection for your company resources
More protection for your company resources Floor standing cabinets 10 TecnoCustom 22 Wall Cabinets 26 Fiber Optic Enclosures and Cabinets 38 Cable Management 42 Accessories 48 Shelves 58 Power Distribution
More informationUncompromising safety and comfort The next generation of miniature circuit breakers MCB S 200/S 200 M
Uncompromising safety and comfort The next generation of miniature circuit breakers MCB S 200/S 200 M The details make the difference MCB S 200/S 200 M A range designed to ensure efficiency and protection
More informationActuator-Sensor-Interface
Selection and ordering data Design Order No. Price Pack 3RX9 307-0AA00 3RX9 307-1AA00 4FD5 213-0AA10-1A 3RX9 305-1AA00 3RX9 306-1AA00 Single output IP 65 current 2.4 A Rated input voltage DC 24 V current
More informationDIGITUS Network & Server Cabinets. UNIQUE Series
DIGITUS Network & Server Cabinets UNIQUE Series Benefits - Server Rack 4-Point locking system front door 3-point locking system rear door Swing handle lock with profile zylinder in front and rear door
More informationIntel Server System S7000FC4UR
Intel Server System S7000FC4UR Power Cord Enabling Specification January, 2007 Enterprise Platforms and Services Division - Marketing Intel Server System S7000FC4UR Power Supply Specification Revision
More informationPB accessories. PB accessories. Labelling option. Order Information B4-2728. Printed board handle A BZA42727 BZA42724.
Printed board handle A Assembly behind front panels Only use printed board handle in conjunction with printed board retainer A (6087-097) Insertion and extraction function Labelling option B4-2728 Item
More informationTROUBLESHOOTING PRELIMINARY
TROUBLESHOOTING PRELIMINARY To troubleshoot, one must first have a working knowledge of the individual parts and their relation to one another. Must have adequate hand tools Must have basic instrumentation:
More information