GAS DECK OVEN INSTALLATION - OPERATION - MAINTENANCE
|
|
|
- Garey Cross
- 10 years ago
- Views:
Transcription
1 1060 GAS DECK OVEN INSTALLATION - OPERATION - MAINTENANCE BLODGETT OVEN COMPANY 44 Lakeside Avenue, Burlington, Vermont USA Telephone: (802) Fax: (802) PN Rev M (2/15) G.S. Blodgett Corporation
2 Your Service Agency s Address: Model Serial number Oven installed by Installation checked by
3 IMPORTANT WARNING: Improper installation, adjustment, alternation, service or maintenance can cause property damage, injury or death. Read the instllation, operation and maintenance instructions thoroughly before installing or servicing this equipment. INSTRUCTIONS TO BE FOL- LOWED IN THE EVENT THE USER SMELLS GAS MUST BE POSTED IN A PROMINENT LO- CATION. This information may be obtained by contacting your local gas supplier. FOR YOUR SAFETY Do not store or use gasoline or other flammable vapors or liquids in the vicinity of this or any other appliance. The information contained in this manual is important for the proper installation, use, and maintenance of this oven. Adherence to these procedures and instructions will result in satisfactory baking results and long, trouble free service. Please read this manual carefully and retain it for future reference. ERRORS: Descriptive, typographic or pictorial errors are subject to correction. Specifications are subject to change without notice. TABLE OF CONTENTS INSTALLATION Oven Description and Specifications... 2 Delivery and Location... 3 Oven Assembly... 4 Packaging... 4 Leg Attachment... 4 caster attachment... 4 Double Section Assembly Piece Deflector Assembly... 5 Ultra Rokite Shelves... 5 Deck Seal... 6 Flue Plates... 6 Leveling the Oven... 6 Adjustments Associated with Initial Installation... 6 Ventilation... 7 Utility Connections - Standards and Codes... 9 Gas Connection Gas Piping Pressure Regulation and Testing Gas Hose Restraint Initial Startup OPERATION Safety Information Oven Control General Guidelines for Operating Personnel MAINTENANCE Cleaning and Preventative Maintenance Troubleshooting Guide... 18
4 Installation Oven Description and Specifications Blodgett Deck ovens have set industry wide standards of excellence for baking characteristics, performance and reliability. They remain unsurpassed for product quality. Simplicity of design and quality construction throughout assure years of trouble free service when the equipment is properly installed and maintained. Features include a full angle iron frame, all welded radius corners and stainless steel fronts and doors. gas ratings Natural Gas Propane US Units SI Units US Units SI Units Heating Value 1000 BTU/hr 37.3 MJ/m BTU/hr 95.0 MJ/m 3 Specific Gravity (air=1.0) Gas Manifold Pressure 3.5 W.C kpa 10 W.C kpa Oven Input Per Burner Per Oven 42,500 BTU/hr 85,000 BTU/Hr 12.4 kw 24.9 kw 42,500 BTU/Hr 85,000 BTU/Hr 12.4 kw 24.9 kw Main Burner Orifice Size 30 MTD* 3.3 mm 48 MTD* 1.93 mm Pilot Burner Orifice Size.021 Dia..53 mm.0115 Dia..29 mm NOTE: * - Multiple Twist Drill 2
5 Installation Delivery and Location Delivery and inspection All Blodgett ovens are shipped in containers to prevent damage. Upon delivery of your new oven: Inspect the shipping container for external damage. Any evidence of damage should be noted on the delivery receipt which must be signed by the driver. Uncrate the oven and check for internal damage. Carriers will accept claims for concealed damage if notified within fifteen days of delivery and the shipping container is retained for inspection. The Blodgett Oven Company cannot assume responsibility for loss or damage suffered in transit. The carrier assumed full responsibility for delivery in good order when the shipment was accepted. We are, however, prepared to assist you if filing a claim is necessary. oven location The well planned and proper placement of your oven will result in long term operator convenience and satisfactory performance. The following clearances must be maintained between the oven and any combustible or non-combustible construction. Oven body right side - 6 (15 cm) Oven body left side - 6 (15 cm) Oven body back - 6 (15 cm) Oven body bottom - 6 (15 cm) The following clearance must be available for servicing. Oven body left side - 12 (30.5 cm) NOTE: On gas models, routine servicing can usually be accomplished within the limited movement provided by the gas hose restraint. If the oven needs to be moved further from the wall, the gas must first be turned off and disconnected from the oven before removing the restraint. Reconnect the restraint after the oven has been returned to its normal position. It is essential that an adequate air supply to the oven be maintained to provide a sufficient flow of combustion and ventilation air. Place the oven in an area that is free of drafts. Keep the oven area free and clear of all combustibles such as paper, cardboard, and flammable liquids and solvents. Do not place the oven on a curb base or seal to a wall. This will restrict the flow of air and prevent proper ventilation. Pilot outages or yellow, floating flames on the main burners are indicative of a lack of secondary air. The oven must be installed with the legs supplied by the manufacturer. Before making any utility connections to this oven, check the rating plate to be sure the oven specifications are compatible with the gas and electrical services supplied for the oven. 1. Pull out control panel. The rating plate is attached to the inside of the control compartment. 3
6 Installation Oven Assembly Packaging Before beginning assembly and installation of the oven, check that all necessary components have been received. In addition to the oven itself, legs, the proper vent, and/or other accessories may be required. Single Sections 1060 with Steel Deck Legs, regulator, set of flue plates, draft diverter and steel deck are shipped in the oven. Drafthood (when supplied) is packed separately with Ultra Rokite Decks Legs, regulator, set of flue plates and draft diverter are shipped in oven. Ultra Rokite decks are packed in a separate carton. Drafthood (when supplied) is packed separately. Double Sections 1060 with Steel Deck Legs and bolts, regulator, set of flue plates and steel deck are packed in the lower section. Regulator, set of flue plates, draft diverter and steel deck are packed in the upper section. Crown angle leg frame is packed in a separate carton. Drafthood (when supplied) is packed in a separate carton with Ultra Rokite Decks Legs and bolts, regulator, set of flue plates are packed in the lower section. Regulator, draft diverter and a set of flue plates are packed in the upper section. Ultra Rokite decks are packed in two separate cartons. Crown angle leg frame is packed in a separate carton. Drafthood (when supplied) is packed in a separate carton. Leg Attachment 1. Put the oven onto a genie lift with the bottom of the oven down. Be careful not to damage the louvered panel under the oven. 2. Each leg is attached by three bolts to the underside of the oven base frame. caster attachment 1. Bolt supports to oven with 1/2-13 hex head bolts (casters with brakes should be facing front of oven.) 2. Carefully place oven onto the casters. (It will be necessary to have several persons lift oven off the pallet and set it onto the casters). Engage brakes on front casters. NOTE: A fixed restraint must be provided if casters are used in conjunction with a flexible connector for movable appliances. This restraint must secure the oven to a non-movable surface to eliminate stress on the connector. If the oven is moved, the restraint must be reconnected after the oven is returned to it s normal position. 4
7 Installation Oven Assembly Double Section Assembly 1. Fasten 12 (305 mm) legs to lower section. 2. Remove the sheet metal flue cover on bottom of UP- PER SECTION FLUE ONLY and save the two screws. 3. Fasten crown angle leg frame to upper sections. 4. Insert double oven flue connector into upper oven section flue until it is flush with the base angle. Temporarily hold in place with tape. 5. Install upper section on bottom section. 6. Remove tape and slide flue connector into position over the collar of the bottom section. 7. Fasten flue connector to bottom section with screws from the flue cover. 8. Install drafthood or draft diverter with screws provided. 3 Piece Deflector Assembly 1. Deflectors are shipped in place in the oven. No assembly is required. 2. Remove the shipping clip located in the back center of each deflector before inserting two-piece shelf assembly. Ultra Rokite Shelves 1. Slide the 12 wide Ultra Rokite shelf through the door opening to the rear of the oven until it drops into the shelf support. 2. Slide one of the two 24 wide shelves through the door opening to the rear on the center shelf until it is within the shelf support. Slide all the way to the left until it drops down in place. 3. Slide the other 24 wide shelf through the door opening to the rear on the center shelf until it is within the shelf support. Slide all the way to the right until it drops down in place. 4. Pry the three sections inward so the joints close. 5. Install the deck seal between the door and the frame. NOTE: Due to the weight of the Ultra Rokite shelves, take care to avoid injury to yourself or damage to the shelves when sliding sections into the oven. Figure 1 Figure 2 5
8 Installation Oven Assembly Deck Seal 1. Place the long lip of the deck seal in front of the shelf support angle. Place the shorter lip with the notches between the shelf support angle and the shelf. 2. Push seal down into place. Figure 3 Flue Plates 1. Insert the back end of the flue plate in the vertical channel in the rear of the oven compartment. 2. Swing the flue plate outward toward the oven side wall. 3. Raise the front end of the flue plate about 1/2. slip the two tabs on the flue plate in the matched angle on the front wall. 4. Drop the flue plate down into place. Leveling the Oven Ovens are equipped with NSF listed adjustable sanitary legs. 1. Level ovens side to side and front to back by placing spirit level on base frame of lower section. 2. Adjust leg feet in or out as appropriate. Adjustments Associated with Initial Installation Each oven, and its component parts, have been thoroughly tested and inspected prior to shipment. However, it is often necessary to further test or adjust the oven as part of a normal and proper installation. These adjustments are the responsibility of the installer, or dealer. Since these adjustments are not considered defects in material or workmanship, they are not covered by the Original Equipment Warranty. They include, but are not limited to: calibration of the thermostat adjustment of the doors burner adjustments leveling testing of gas pressure tightening of fasteners No installation should be considered complete without proper inspection, and if necessary, adjustment by qualified installation or service personnel. Figure 4 6
9 Installation Ventilation Blodgett gas deck ovens are direct fired. Heat and flue products from the burners are introduced directly into the baking compartment. As a result, improper venting can have a detrimental effect on the baking characteristics of the oven. A properly designed ventilation system will allow the oven to function properly, while removing unwanted vapors and products of combustion from the operating area. This oven may be vented using either: A mechanically driven, canopy type, exhaust hood, or A direct flue arrangement. U.S. and Canadian installations Refer to your local ventilation codes. In the absence of local codes, refer to the National ventilation code titled, Standard for the Installation of Equipment for the Removal of Smoke and Grease Laden Vapors from Commercial Cooking Equipment, NFPA-96-Latest Edition. General export installations Installation must conform with Local and National installation standards. Local installation codes and/or requirements may vary. If you have any questions regarding the proper installation and/or operation of your Blodgett oven, please contact your local distributor. If you do not have a local distributor, please call the Blodgett Oven Company at The Blodgett Oven Company cannot assume responsibility for loss or damage suffered as a result of improper installation. Canopy Type Exhaust Hood A mechanically driven, canopy type exhaust hood is the preferred method of ventilation. The hood should be sized to completely cover the equipment plus an overhang of at least 6 (15 cm) on all sides not adjacent to a wall. The distance from the floor to the lower edge of the hood should not exceed 7 (2.1m). The capacity of the hood should be sized appropriately with provisions for an adequate supply of make up air. Capacity is generally expressed in ft3/min (CFM). 1 CFM of natural gas burned with just enough air for complete combustion produces 11 CFM of combustion products. In virtually all appliances some excess air is used. This volume of excess air is added to the flue products flowing from the appliance. NOTE: Consult your local exhaust hood contractor for your specific installation. Installing the canopy hood draft diverter Ovens ordered for hood venting are supplied with a draft diverter. Install the draft diverter as follows: 1. Place the diverter over the flue connector with the open area facing the front of the oven. 2. Secure both ends with the sheet metal screws provided. Draft Diverter WARNING: Failure to properly vent the oven can be hazardous to the health of the operator and may result in operational problems, unsatisfactory baking and possible damage to the equipment. Damage sustained as a direct result of improper ventilation will not be covered by the Manufacturer s warranty. Figure 5 Front of Oven 7
10 Ventilation Installation Direct Flue Arrangement When the installation of a mechanically driven exhaust hood is impractical the oven may be vented by a direct flue arrangement. WARNING!! It is essential that the direct flue be installed as follows. Incorrect installation will result in unsatisfactory baking and oven damage. The flue must be class B or better with a diameter of 10 (25.4 cm). The height of the flue should rise 6-8 ft (2-2.5 m) above the roof of the building or any proximate structure. Never direct vent the oven into a hood. The flue should be capped with a UL Listed type vent cap to isolate the unit from external environmental conditions. The direct vent cannot replace air consumed and vented by the oven. Provisions must be made to supply the room with sufficient make-up air. Total make-up air requirements for each oven section should be approximately 30 CFM per section. To increase the supply air entering the room, a ventilation expert should be consulted. Installing the draft hood Ovens ordered for direct venting are supplied with a draft hood. Install the draft hood as follows: 1. Place the draft hood over the flue connector. 2. Secure both ends with the sheet metal screws provided. Venting Problems Blodgett gas deck ovens use the natural principal of heat rising as the basic method of ventilation. If the venting of any deck oven is either restricted or forced in any way the baking characteristics of the oven will be adversely affected. Examples of forced venting include: installation of a fan in a direct vent pipe use of a canopy type hood without the draft diverter Examples of restricted venting include: use of tees and elbows long horizontal runs Insufficient make-up air can cause heated air and combustibles to remain in the oven shortening the life of the components. Flue Draft Hood Front of Oven Figure 6 8
11 Installation Utility Connections - Standards and Codes THE INSTALLATION INSTRUCTIONS CONTAINED HEREIN ARE FOR THE USE OF QUALIFIED INSTAL- LATION AND SERVICE PERSONNEL ONLY. INSTAL- LATION OR SERVICE BY OTHER THAN QUALIFIED PERSONNEL MAY RESULT IN DAMAGE TO THE OVEN AND/OR INJURY TO THE OPERATOR. Qualified installation personnel are individuals, a firm, a corporation, or a company which either in person or through a representative are engaged in, and responsible for: the installation or replacement of gas piping and the connection, installation, repair or servicing of equipment. Qualified installation personnel must be experienced in such work, familiar with all precautions required, and have complied with all requirements of state or local authorities having jurisdiction. U.S. and Canadian installations Installation must conform with local codes, or in the absence of local codes, with the National Fuel Gas Code, NFPA54/ANSI Z223.1-Latest Edition, the Natural Gas Installation Code CAN/CGA-B149.1 or the Propane Installation Code, CAN/CGA-B149.2 as applicable. General export installations Installation must conform with Local and National installation standards. Local installation codes and/or requirements may vary. If you have any questions regarding the proper installation and/or operation of your Blodgett oven, please contact your local distributor. If you do not have a local distributor, please call the Blodgett Oven Company at
12 Installation Gas Connection Gas Piping A properly sized gas supply system is essential for maximum oven performance. Piping should be sized to provide a supply of gas sufficient to meet the maximum demand of all appliances on the line without loss of pressure at the equipment. Example: NOTE: BTU values in the following example are for natural gas. You purchase a 1060-B deck oven to add to your existing cook line. 1. Add the BTU rating of your current appliances. Pitco Fryer 120,000 BTU 6 Burner Range 60,000 BTU Deck Oven 50,000 BTU Total 230,000 BTU 2. Add the BTU rating of the new oven to the total. Previous Total 230,000 BTU 1060-B 85,000 BTU New Total 315,000 BTU 3. Measure the distance from the gas meter to the cook line. This is the pipe length. Let s say the pipe length is 40 (12.2 m) and the pipe size is 1 (2.54 cm). 4. Use the appropriate table to determine the total capacity of your current gas piping. The total capacity for this example is 320,000 BTU. Since the total required gas pressure, 315,000 BTU is less than 320,000 BTU, the current gas piping will not have to be increased. NOTE: The BTU capacities given in the tables are for straight pipe lengths only. Any elbows or other fittings will decrease pipe capacities. Contact your local gas supplier if you have any questions. Maximum Capacity of Iron Pipe in Cubic Feet of Natural Gas Per Hour (Pressure drop of 0.5 Inch W.C.) Pipe Nominal Size, Inches Length (ft) 3/ /4 1-1/ From the National Fuel Gas Code Part 10 Table 10-2 Maximum Capacity of Pipe in Thousands of BTU/hr of Undiluted L.P. Gas at 11 W.C. (Pressure drop of 0.5 Inch W.C.) Pipe Outside Diameter, Inches Length (ft) 3/ / From the National Fuel Gas Code Part 10 Table
13 Installation Gas Connection Pressure Regulation and Testing Each section of the 1060-B series oven is rated at 85,000 BTU per hour (24.9 kw). At full demand, each section 1060-BL oven requires 85 cubic feet per hour (2.4 m3) Natural gas or 33 cubic feet per hour (0.9 m3) Propane gas. Each oven has been adjusted at the factory to operate with the type of gas specified on the rating plate. Inlet Pressure Natural Propane Min Max Min Max W.C kpa Manifold Pressure Natural Propane W.C kpa Inlet Pressure - the pressure of the gas before it reaches the oven. Manifold Pressure - the pressure of the gas as it enters the main burner(s). Min - the minimum pressure recommended to operate the oven. Max - the maximum pressure at which the manufacturer warrants the oven s operation. Each oven is supplied with a regulator to maintain the proper gas pressure. The regulator is essential to the proper operation of the oven and must be installed. It is preset to provide the oven with 3.5 W.C. (0.87 kpa) for natural gas and 10.5 W.C. (2.50 kpa) for Propane at the manifold. DO NOT INSTALL AN ADDITIONAL REGULATOR WHERE THE OVEN CONNECTS TO THE GAS SUP- PLY UNLESS THE SUPPLY EXCEEDS THE MAXIMUM PRESSURE. Due to the decrease in oxygen at higher elevations, above 2000, the unit may need to be rerated. (The orifice size may need to be adjusted to accomodate different air pressures at higher elevations.) If not rerated, incomplete combustion may occur releasing Aldehydes and CO or Carbon Monoxide. Any of these are unacceptable and may be hazardous to the health of the operator. Prior to connecting the oven, gas lines should be thoroughly purged of all metal filings, shavings, pipe dope, and other debris. After connection, the oven should be checked for correct gas pressure. Installation must conform with local codes, or in the absence of local codes, with the National Fuel Gas Code, NFPA54/ANSI Z223.1-Latest Edition, the Natural Gas Installation Code CAN/CGA-B149.1 or the Propane Installation Code, CAN/CGA-B149.2 as applicable. The oven and its individual shutoff valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 1/2 psig (3.45kPa). The oven must be isolated from the gas supply piping system by closing its individual manual shutoff valve during any pressure testing of the gas piping system at test pressures equal or less than 1/2 psig (3.45kPa). 11
14 Installation Gas Connection Gas Hose Restraint If the oven is mounted on casters, a commercial flexible connector with a minimum of 3/4 (1.9 cm) inside diameter must be used along with a quick connect device. The restraint, supplied with the oven, must be used to limit the movement of the unit so that no strain is placed upon the flexible connector. With the restraint fully stretched the connector should be easy to install and quick connect. The restraint (ie: heavy gauge cable) should be 1,000 lb. (453 kg) test load and should be attached without damaging the building. DO NOT use the gas piping or electrical conduit for the attachment of the permanent end of the restraint! Use anchor bolts in concrete or cement block. On wooden walls, drive hi test wood lag screws into the studs of the wall. 1. Mount the supplied bracket to the leg bolt just below the gas inlet. 2. The clip on restraining cable can be attached to the mounting bracket. Back of Oven Restraint Cable Bracket WARNING!! If the restraint is disconnected for any reason it must be reconnected when the oven is returned to its original position. U.S. and Canadian installations The connector must comply with the Standard for Connectors for Movable Gas Appliances, ANSI Z21.69 or Connectors For Moveable Gas Appliances CAN/CGA and a quick disconnect device that complies with the Standard for Quick-Disconnect Devices for Use With Gas Fuel, ANSI Z21.41 or Quick Disconnect For Use With Gas Fuel CAN Adequate means must be provided to limit the movement of the appliance without depending on the connection and the quick disconnect device or its associated piping. Adequate means must be provided to limit the movement of the appliance without depending on the connection and the quick disconnect device or its associated piping. General export installations The restraint and quick connect must conform with Local and National installation standards. Local installation codes and/or requirements may vary. If you have any questions regarding the proper installation and/or operation of your Blodgett oven, please contact your local distributor. If you do not have a local distributor, please call the Blodgett Oven Company at Double stacked unit shown. Use the same procedure for single units with 25 (64 cm) legs. Figure 7 12
15 Operation Initial Startup Adjustments associated with initial installation Each oven, and its component parts, have been thoroughly tested and inspected prior to shipment. However, it is often necessary to further test or adjust the oven as part of a normal and proper installation. These adjustments are the responsibility of the installer, or dealer. Since these adjustments are not considered defects in material or workmanship, they are not covered by the Original Equipment Warranty. They include, but are not limited to: calibration of the thermostat adjustment of the doors burner adjustments leveling testing of gas pressure tightening of fasteners No installation should be considered complete without proper inspection, and if necessary, adjustment by qualified installation or service personnel. 13
16 Operation Safety Information The information contained in this section is provided for the use of qualified operating personnel. Qualified operating personnel are those who have carefully read the information contained in this manual, are familiar with the functions of the oven and/or have had previous experience with the operation of the equipment described. Adherence to the procedures recommended herein will assure the achievement of optimum performance and long, trouble-free service. Please take the time to read the following safety and operating instructions. They are the key to the successful operation of your Blodgett oven. SAFETY TIPS For your safety read before operating What to do if you smell gas: DO NOT try to light any appliance. DO NOT touch any electrical switches. Use an exterior phone to call your gas supplier immediately. If you cannot reach your gas supplier, call the fire department. What to do in the event of a power failure: Turn all switches to off. DO NOT attempt to operate the oven until the power is restored. NOTE: In the event of a shut-down of any kind, allow a five (5) minute shut off period before attempting to restart the oven. General safety tips: DO NOT use tools to turn off the gas control. If the gas cannot be turned off manually do not try to repair it. Call a qualified service technician. If the oven needs to be moved for any reason, the gas must be turned off and disconnected from the unit before removing the restraint cable. Reconnect the restraint after the oven has been returned to its original location. DO NOT remove the control panel cover unless the oven is unplugged. 14
17 control description Operation Oven Control 1. automatic safety pilot valve - provides complete gas shut-off in the event of pilot failure. 2. manual control valve - provides manual control of gas flow to the main burner through the thermostat. 3. THERMOSTAT - Provides regulation of oven temperature at setting selected by the oven operator. operation The operation of the 1060 Oven is as simple as 1, 2, 3. - Lighting, Preheating and Loading. Lighting 1. Turn the manual control valve (2) to OFF. 2. Push the red button on the automatic safety pilot valve (1). 3. Apply a lighted match or taper to pilot burner. 4. After pilot burner lights, continue to depress red button for about 30 seconds and release. 5. Turn the manual control valve (2) to ON. 6. Set THERMOSTAT (3) to desired temperature. Preheating 1. On initial startup, preheat the oven to 600ºF (315ºC) over a period of four hours in increments of 100ºF (55ºC) starting at 300ºF (149ºC). Check the oven periodically. This will temper the Ultra Rokite shelves and burn off any oil and fiberglass residue. NOTE: The 1060 (with Ultra Rokite shelves) will require an additional 20 minutes on a preheat to 600ºF (315ºC). Loading Pizza in pans should be placed in rotation on the shelf allowing it to recover its loss of temperature from the previous bake. Do not allow pans to touch each other or sides of oven. Open doors as seldom as possible. The deck is intended for cooking pizza and bread products, other types of food may be cooked in pans or containers. To turn the oven off 1. Turn the manual control valve (1) to OFF. Figure 8 NOTE: When the oven is shut down, place the Main Manual Control Valve in the OFF position. It is not necessary to extinguish the pilot flame. 15
18 Operation General Guidelines for Operating Personnel Cook Times and Temperatures Cook Temperatures Cook temperatures vary with different products. Experiment with the initial bakes until you find the ideal combination of time and temperature. Example: pizza 1. Run several bakes at 500ºF (260ºC). Make note of the time required to achieve a firm crust. 2. If the cheese breaks down too quickly or scorches, lower the temperature and lengthen the bake time. 3. If faster production is desired, run additional bakes increasing the temperature by increments of 25ºF (15ºC). 4. Record the results to determine the highest temperature at which you can bake and achieve quality results with maximum production. NOTE: Pull time is critical at high temperatures. Cook Time Cook times vary with the amount of product loaded, the type of pan and the temperature. Raising the temperature to lower the cook time is effective to a point. Then the quality of the bake begins to suffer. baking tips Scale dough for consistent product. Proof dough to proper consistency. Refrigerated dough or pies should be brought to room temperature before baking. Bubbles may occur when baking refrigerated product. Break bubbles if necessary. Alternate use between upper and lower section in a double oven. Avoid frequent needless opening of the door Rotate product placement in the oven. 16
19 Maintenance Cleaning and Preventative Maintenance cleaning the oven Painted and stainless steel ovens may be kept clean and in good condition with a light oil. 1. Saturate a cloth, and wipe the oven when it is cold. 2. Dry the oven with a clean cloth. On the stainless front or interiors, deposits of baked on splatter may be removed with any non-toxic industrial stainless steel cleaner. Heat tint and heavy discoloration may be removed with any non-toxic commercial oven cleaner. 1. Apply cleaners when the oven is cold, and always rub with the grain of the metal. Clean Ultra Rokite decks with a triangular scraper used for cleaning broiler grids. IMPORTANT - DO NOT use water or any other liquids to clean the deck! Clean the aluminized interior portion of the oven with a mild detergent. DO NOT use caustic solutions such as ammonia, lye or soda ash. DO NOT use domestic oven cleaners. Any of these products will damage the aluminum coating. Daily Cleaning Remove residue from beneath the doors with a small broom or brush. Weekly Cleaning Brush out the combustion compartment and control area. 6 Month Cleaning Clean secondary air ducts and air entry ports. NOTE: If the oven is moved the restraint must be reconnected after the unit is returned to it s regular position. preventative maintenance The best preventative maintenance measures are, the proper installation of the equipment and a program for routinely cleaning the ovens. This oven requires no lubrication, however, the venting system should be checked annually for possible deterioration resulting from moisture and corrosive flue products. If maintenance or repairs are required, contact the factory, the factory representative or a local Blodgett service company. 17
20 Maintenance Troubleshooting Guide POSSIBLE CAUSE(S) SYMPTOM: Strong bottoms on the bakes Too much bottom heat High gas pressure Faulty flue (strong direct vent) Product left in the oven too long SUGGESTED REMEDY Reduce cook temperature and increase time Shorten cook time SYMPTOM: Uneven bakes Poor ventilation Oven doors left open too long Improper scaling of dough Fluctuating gas pressure Warped pans Do not open door unnecessarily Scale dough consistently Change pans SYMPTOM: Product burning Thermostat set too high Product left in the oven too long By-pass flame too high High gas pressure Thermostat out of calibration Heat deflectors worn out Reduce cook temperature Shorten cook time *Denotes remedy is a difficult operation and should be performed by qualified personnel only. It is recommended, however, that All repairs and/or adjustments be done by your local Blodgett service agency and not by the owner/operator. Blodgett cannot assume responsibility for damage as a result of servicing done by unqualified personnel. WARNING!! Always disconnect the power supply before cleaning or servicing the oven. 18
21 Maintenance Troubleshooting Guide POSSIBLE CAUSE(S) SYMPTOM: Product dried out Oven temperature too low Not using enough water in the mix Thermostat out of calibration Faulty flue (strong direct vent) SUGGESTED REMEDY Increase cook temperature Increase water in product mix SYMPTOM: Extended baking times Temperature setting too low Low gas pressure Strong ventilation Excessive door openings Increase cook time Do not open door unnecessarily *Denotes remedy is a difficult operation and should be performed by qualified personnel only. It is recommended, however, that All repairs and/or adjustments be done by your local Blodgett service agency and not by the owner/operator. Blodgett cannot assume responsibility for damage as a result of servicing done by unqualified personnel. WARNING!! Always disconnect the power supply before cleaning or servicing the oven. 19
INSTALLATION AND OPERATIONS GUIDE FOR GRAND CANYON GAS LOG SYSTEMS
INSTALLATION AND OPERATIONS GUIDE FOR GRAND CANYON GAS LOG SYSTEMS Installation and service must be provided by a qualified installer, service agency or gas supplier Grand Canyon Gas Logs, logs are made
Your safety and the safety of others are very important.
NATURAL GAS TO PROPANE CONVERSION KIT 090 INSTALLATION INSTRUCTIONS FOR ALTITUDES 0 -,00 FT. ONLY PROPANE CONVERSION KIT SAFETY... INSTALLATION REQUIREMENTS... Tools and Parts... LP Gas Requirements...
Cooktop Low-Profile Ventilation Hoods
INSTALLATION GUIDE Cooktop Low-Profile Ventilation Hoods Contents Wolf Cooktop Low-Profile Ventilation Hoods........ 3 Cooktop Low-Profile Hood Specifications.......... 4 Cooktop Low-Profile Hood Installation............
orlando OWNER S MANUAL
orlando OWNER S MANUAL 2 Assembling & operating manual Orlando 30 mbar - PORTABLE GAS BARBECUE 1. 2. 3. Improper installation, adjustment, alteration, service or maintenance can injury or property damage.
PRE-ASSEMBLED INSTALLATION INSTRUCTIONS FOR PACB SERIES COAL FIRED OVENS
PRE-ASSEMBLED INSTALLATION INSTRUCTIONS FOR PACB SERIES COAL FIRED OVENS OVENS MANUFACTURED BY: EARTHSTONE OVENS-6717 SAN FERNANDO RD GLENDALE CA 91201 TELEPHONE: 800-840-4915 818-553-1134 FAX: 818-553-1133
CROWN BOILER COMPANY BWF SERIES BOILER CATEGORY I VENT KIT INSTALLATION AND OPERATING INSTRUCTIONS
CROWN BOILER COMPANY BWF SERIES BOILER CATEGORY I VENT KIT INSTALLATION AND OPERATING INSTRUCTIONS WARNING Improper installation, adjustment, alteration, service, or maintenance of this product can cause
COMMERCIAL COOKING HOODS, VENTILATION & FIRE SUPPRESSION SYSTEM GUIDELINES AND PROCEDURES
COMMERCIAL COOKING HOODS, VENTILATION & FIRE SUPPRESSION SYSTEM GUIDELINES AND PROCEDURES These guidelines are to be used for ALL commercial cooking hoods, ventilation systems and related fire suppression
American Fireglass Outdoor Fire pit kit information. General instructions/warnings for outdoor gas pan and burner systems
American Fireglass Outdoor Fire pit kit information General instructions/warnings for outdoor gas pan and burner systems We strongly recommend that our burner products be installed by a licensed and certified
ASX7-4-IOM-7 J30-08579
INSTALLATION INSTRUCTIONS 4" COMBUSTION AIR INLET KIT TUBULAR GAS FIRED DIRECT SPARK PROPELLER UNIT HEATERS UNIT CONVERSION & CATEGORY III VENTING FOR SEPARATED COMBUSTION For 30,000 to 75,000 BTU/HR SUPPLEMENT
GAS SAFETY PRECAUTIONS
GAS SAFETY PRECAUTIONS Instructions on what to do when a user smells gas can be obtained from the local gas supplier. These instructions must be posted in a prominent location where the unit is to be operated.
!"" #$% "!&' ( ( ) *
!"" #$% "!&' (( ) * G Whiz Gas Popper Instruction Manual Model #5908 Part No. 74874 Revised October 1997 Cincinnati, OH 45241-4807 USA GAS SAFETY PRECAUTIONS Instructions on what to do when a user smells
SL280UHV SERIES GAS FURNACE WARNING
2010 Lennox Industries Inc. Dallas, Texas, USA 506677 01 11/2010 Supersedes 506409 01 SL280UHV SERIES GAS FURNACE Litho U.S.A. FIRE OR EXPLOSION HAZARD. Failure to follow safety warnings exactly could
San josé OWNER S MANUAL
San josé OWNER S MANUAL Assembling & operating manual San josé 30 mbar - PORTABLE GAS BARBECUE 1. 2. 3. Improper installation, adjustment, alteration, service or maintenance can injury or property damage.
ATS Overhead Table Shelf System INSTRUCTION MANUAL
ATS Overhead Table Shelf System INSTRUCTION MANUAL ATS Overhead Table Shelf System Instruction Manual Warranty Newport Corporation warrants this product to be free of defects in material and workmanship
USER S, MAINTENANCE and SERVICE INFORMATION MANUAL
CONTENTS SAFETY INFORMATION................ 2 FOR YOUR SAFETY....................... 2 SYSTEM OPERATION.................. 2 THERMOSTATS........................... 2 INTERMITTENT IGNITION DEVICE...........
NOTE! READ INSTRUCTIONS FULLY BEFORE INSTALLING OR OPERATING.
INSTALLATION AND OPERATION GUIDE FOR HARGROVE GAS LOGS PROPANE GAS ADEQUATE FIREPLACE VENTILATION IS REQUIRED FOR SAFETY. GAS LOGS MUST BE INSTALLED BY PERSONNEL QUALIFIED FOR INSTALLING GAS APPLIANCES.
Applies to: Models F, B, FE, and BE FOR YOUR SAFETY
Form CP-F/B-GC (Version A.2) Obsoletes Form CP-F/B-GC (Version A) Gas Conversion Kits and Instructions Applies to: Models F, B, FE, and BE Model B Model F All gas conversion must be done by a qualified
CARING FOR YOUR WATER HEATER
http://waterheatertimer.org/troubleshoot-rheem-tankless-water-heater.html Water Heater Inspections CARING FOR YOUR WATER HEATER Venting System (Direct Vent Only) The venting system should be inspected
IMPORTANT INSTRUCTIONS & OPERATING MANUAL. Houston 50 Inch Electric Wall Mounted Fireplace Black / White
IMPORTANT INSTRUCTIONS & OPERATING MANUAL Houston 50 Inch Electric Wall Mounted Fireplace Black / White Model Number:MFE5050BK Model Number:MFE5050WH Read these instructions carefully before attempting
TWIN EAGLES ALL WEATHER ELECTRIC RADIANT HEATER
TWIN EAGLES, INC. Defining the Art of Outdoor Cooking TWIN EAGLES ALL WEATHER ELECTRIC RADIANT HEATER OWNER S MANUAL MODEL TEEH-1512 TEEH-2524 TEEH-3524 NEED ASSISTANCE? PLEASE CALL: (562) 802-3488 This
G26 Corp. 9721-L11 Revised 07-2001 LENNOXOEMPARTS.COM. Service Literature G26 SERIES UNITS
Service Literature G26 SERIES UNITS G26 series units are high-efficiency upflow gas furnaces manufactured with DuralokPlust aluminized steel clamshell-type heat exchangers. G26 units are available in heating
Electric Fryers Instruction Manual Models: 8047D, 8048D, 8049D, 8050D, 8051D 8066, 8068, 8068FL, 8073, 8073BF and 8075
Part No. 89047 Electric Fryers Instruction Manual Models: 8047D, 8048D, 8049D, 8050D, 8051D 8066, 8068, 8068FL, 8073, 8073BF and 8075 Cincinnati, OH 45241-4807 USA ELECTRIC FRYER SAFETY PRECAUTIONS Installation
INSTALLATION AND OPERATION MAINTENANCE
INSTALLATION AND OPERATION MAINTENANCE TSF SERIES FRYER OWNER S MANUAL Models: TSF-3540, TSF-4050, TSF-6575 FOR YOUR SAFETY: Do not store or use gasoline or other flammable vapors or liquids in the vicinity
Convection Ovens. BX Classic. Models BX4 / FG 189C, BX4-6040 / FG 158C, BX10 / FG 180C. Operator's Manual
Convection Ovens BX Classic Models BX4 / FG 189C, BX4-6040 / FG 158C, BX10 / FG 180C Operator's Manual Belshaw Bros., Inc. 814 44 th Street NW, Suite 103 Auburn, WA 98001 USA Phone: 206-322-5474 Fax: 206-322-5425
2010 Residential Water Heater Replacement Check List
2010 Residential Water Heater Replacement Check List The intent of this check list is to provide installers a general reference for the enforcement of code requirements in the Greater San Diego Area. This
Select Radiators Installation Guide
Select Radiators Installation Guide Table of Contents Informational Symbols...3 Before You Begin...4 Select Rough-In... 5 Connection Installation...6 Optional Piping Arrangements...7 Conventional Wall
Your safety and the safety of others are very important.
NATURAL GAS TO PROPANE CONVERSION KIT ALPKT7- INSTALLATION INSTRUCTIONS PROPANE CONVERSION KIT SAFETY... INSTALLATION REQUIREMENTS... Tools and Parts... LP Gas Requirements... INSTALLATION INSTRUCTIONS...
RE-3 : SOLID TOP RANGE RANGE TOP ONLY
VULCAN ELECTRIC SOlid top oven range MODEL: RE-3 - SOLID TOP oven Range RE-3T - SOLID range top only ON CABINET BASE RE-3 : SOLID TOP RANGE Model Re-3T : Solid TOP RANGE TOP ONLY Index: General Data 2
ASK THE EXPERT: Burner Troubleshooting Information & Maintenance
ASK THE EXPERT: Burner Troubleshooting Information & Maintenance The burner is the heart of your BBQ. It is subject to a number of conditions that can cause damage, and lead to potential safety issues.
INSTALLATION AND OPERATION MAINTENANCE
INSTALLATION AND OPERATION MAINTENANCE FRYERS OWNER S MANUAL Models: BPF-3540, BPF-4050, BP-6575 FOR YOUR SAFETY: Do not store or use gasoline or other flammable vapors or liquids in the vicinity of this
Packaged Terminal Air Conditioner Wall Sleeve Installation
Installation & Maintenance Data IM 1196 Group: PTAC Part Number: 910141799 Date: October 2013 Packaged Terminal Air Conditioner Installation x 42" PGAN with Top-Mounted Hydronic Heat Note: Installation
THC 85 INDUSTRIAL / COMMERCIAL SPACE HEATER
THC 85 INDUSTRIAL / COMMERCIAL SPACE HEATER Certified to / Certifié à CGA 2.14 M2000 Conforms to / Conforme à ANSI std Z83.7 2000 Suitable for indoor or outdoor installation / Unvented / Unattended Type
OWNER S MANUAL FORCE 10 MARINE COMPANY 23080 HAMILTON ROAD RICHMOND, BC CANADA V6V 1C9 TEL: (604) 522-0233 FAX: (604) 522-9608
Electric Water Heater OWNER S MANUAL FORCE 10 MARINE COMPANY 23080 HAMILTON ROAD RICHMOND, BC CANADA V6V 1C9 TEL: (604) 522-0233 FAX: (604) 522-9608 If your water Heater is Damaged or you have questions
Commercial Gas Furnace Upflow
Commercial Gas Furnace Upflow Model G24-200 80% A.F.U.E. 200,000 Btuh Input Heating Cap. 7.5 or 10 Tons Nominal Add-On Cooling GUK FEATURES Certified by A.G.A./C.G.A. Laboratories. Heavy gauge painted
Safe Method: Gas Safety in Catering Establishments
Safe Method: Gas Safety in Catering Establishments Safety Point Why? What do you do? Gas equipment and services must only be installed, maintained and repaired by a Gas Safe registered installer. Check
MUGNAINI ITALY S ORIGINAL PIZZA OVEN
Mugnaini Series MUGNAINI ITALY S ORIGINAL PIZZA OVEN COMMERCIAL GAS FIRED OVEN INSTALLATION, OPERATION AND MAINTENANCE MANUAL Mugnaini Commercial Gas Fired Ovens have been tested to: ANSI Z83.11 & CAN/CGA
Propane Conversion Kit PROPANE CONVERSION KIT INSTALLATION MANUAL
Propane Conversion Kit Supersedes: 145.25-IOM2 (708) Form 145.25-IOM2 (908) PROPANE CONVERSION KIT INSTALLATION MANUAL "LPKIT " - PROPANE CONVERSION KIT Kits are available for field conversion from natural
Owner Retain this manual in a safe place to provide your serviceman information if it becomes necessary.
INSTALLATION, OPERATING AND SERVICE MANUAL FOR EASY RADIANT WORKS HEATWAVE MODEL GH-25-40 GAS FIRED, VENTED INFRARED TUBE HEATER FOR RESIDENTIAL & COMMERCIAL / INDUSTRIAL APPLICATIONS. For Your Safety
Foodservice Equipment Specialists P.O. Box 880 Saco, ME. / U.S.A. 04072 877-854-8006 * FAX (207) 283-8080
Foodservice Equipment Specialists P.O. Box 880 Saco, ME. / U.S.A. 04072 877-854-8006 * FAX (207) 283-8080 FOR SERVICE ASSISTANCE U.S. AND CANADA CALL: 1-877-854-8006 24 HOURS/DAY 7 DAYS/WEEK TABLE OF CONTENTS
BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS
BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS PLEASE READ COMPLETE INSTRUCTIONS BEFORE YOU BEGIN LEAVE INSTALLATION INSTRUCTIONS AND USER'S GUIDE WITH OWNER ALL ELECTRIC WIRING AND PLUMBING MUST BE DONE
Cleaning Instructions, Pilot Replacement and Valve Change. Model No.: 233010 Natural Gas
Cleaning Instructions, Pilot Replacement and Valve Change Model No.: 233010 Natural Gas 8mm open-end wrench 9mm open-end wrench 10mm open-end wrench 12mm open-end wrench 13mm open-end wrench Phillips screw
DRYER VENTING SPECIFICATIONS DRYER SAFETY
DRYER VENTING SPECIFICATIONS Table of Contents DRYER SAFETY...1 INSTALLATION REQUIREMENTS...4 Venting Requirements...5 DRYER INSPECTION AND CLEANING...7 Frequency of Exhaust System Cleaning...7 Inspecting
Convection TCO600. For your safety and continued enjoyment of this product, always read the instruction book carefully before using.
Convection Toaster Oven TCO600 For your safety and continued enjoyment of this product, always read the instruction book carefully before using. IMPORTANT SAFEGUARDS SAVE AND READ THESE INSTRUCTIONS When
Dehumidifier Users manual. For Models: DH45S DH65S
Dehumidifier Users manual For Models: DH45S DH65S 950-0062-revD Jan. 9 2007 FORWARD The appearance of the units that you purchase might be slightly different from the ones described in the Manual, but
Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CCS. Voltage rating: 115V~60Hz Power rating : 1400W
Portable Air Conditioner OWNER S MANUAL Read these instructions before use Model: MM14CCS Customer Support : 1-800-474-2147 Voltage rating: 115V~60Hz Power rating : 1400W For product inquiries or support
INSTALLATION INSTRUCTIONS - FREESTANDING GAS RANGE
INSTALLATION AND SERVICE MUST BE PERFORMED BY A QUALIFIED INSTALLER. IMPORTANT: SAVE FOR LOCAL ELECTRICAL INSPECTOR'S USE. READ AND SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE. If the information in this
Churrasco/Grill Manual Models: 2ft, 3ft, 4ft, 5ft & 6ft (with or without motor driven spits)
Churrasco/Grill anual odels: 2ft, 3ft, 4ft, 5ft & 6ft (with or without motor driven spits) RETAIN THIS ANUAL FOR FUTURE REFERENCE Hickory Industries, Inc. 4900 Westside Avenue, North Bergen, New Jersey
Utility Distribution Systems
Utility Distribution Systems 6/2012 A0011037 1 WARRANTY This equipment is warranted to be free from defects in materials and workmanship, under normal use and service, for a period of 12 months from date
Vertical Display and Storage B1350-2. SKOPE Gen2: Three Door Chiller
Vertical Display and Storage User Manual MAN1227 Rev. 3.0 March 2008 edition CONTACT ADDRESSES Designed and Manufactured by New Zealand SKOPE INDUSTRIES LIMITED PO Box 1091, Christchurch New Zealand Freephone:
Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MN12CES / MN10CESWW
Portable Air Conditioner OWNER S MANUAL Read these instructions before use 8 Model: MN12CES / MN10CESWW Voltage rating: 120V~60Hz Power rating : 1100W (MN12CES) Power rating : 900W (MN10CESWW) Customer
operator manual Impinger Conveyor Oven Models 3255 & 3270 This document includes:
operator manual Impinger Conveyor Oven Models 3255 & 3270 This document includes: Safety Notices Specifications Installation Instructions Operating Instructions Cleaning Instructions Warranty Statement
BASYS INSTALLATION INSTRUCTIONS FOR ELECTRONIC CAPACITANCE SENSING LAVATORY FAUCETS EFX-3XX Pedestal, Sensor Activated Lavatory Faucets
BASYS INSTALLATION INSTRUCTIONS FOR ELECTRONIC CAPACITANCE SENSING LAVATORY FAUCETS EFX-3XX Pedestal, Sensor Activated Lavatory Faucets Any Application. Any Environment. Code No: 0816407 Rev. 4 (07/12)
PARTS NEEDED FOR CONVERTING FROM LP TO NG
1 6 7 8 3 5 4 10 9 2 PARTS NEEDED FOR CONVERTING FROM LP TO NG Number Description 1 30" NG Manifold 2 NG side burner valve 3 NG Regulator 4 Rear I/R NG orifice 4 Rear I/R NG orifice 5 Side burner NG orifice
Arapahoe County Residential Water Heater Installation and Inspection Guide
Arapahoe County Residential Water Heater Installation and Inspection Guide The attached handout is designed to be a general permit submittal and inspection guide covering most installation instances, however
PRODUCT: WASHER / WASHER-DRYER COMBO MODEL: AW 120 / AW 122 / AW 125 AWD 120 / AWD 121 / AWD 129
PRODUCT: WASHER / WASHER-DRYER COMBO MODEL: The information included in this Splendide Repair Manual may change without notice. Please see our web site www.splendide.com/service/docs.html for updates,
Installer s Guide 18-AH39D1-13
18-AH39D1-13 Cased Aluminum "Convertible" Coils 4TXCA018BC3HC** 4TXCA024BC3HC** 4TXCB025BC3HC** 4TXCB026BC3HC** 4TXCB031BC3HC** 4TXCB032BC3HC** ALL phases of this installation must comply with NATIONAL,
INSTALL INSTRUCTIONS KK-C-HVAC-1 HVAC UNIT 2003-2014 CHEVROLET/GMC VANS FOR
INSTALL INSTRUCTIONS KK-C-HVAC-1 HVAC UNIT 2003-2014 CHEVROLET/GMC VANS FOR (For NEW 2007 ALL WHITE KWIK-KITS ONLY) Warning do not attempt to install A/C units unless you are experienced with servicing
30" GAS RANGE INSTALLATION INSTRUCTIONS (For Models with Sealed Top Burners)
INSTALLATION AND SERVICE MUST BE PERFORMED BY A QUALIFIED INSTALLER. IMPORTANT: SAVE FOR LOCAL ELECTRICAL INSPECTOR'S USE. READ AND SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE. If the information in this
Operating and Installation Instructions
Operating and Installation Instructions System Drawer ESS 2062 To prevent accidents and en - US, CA appliance damage, read these instructions before installation or use. M.-Nr. 07 342 360 Contents IMPORTANT
Cleaning Instructions for Burner, Pilot Assembly, and Emitter Screen Series: 220000-450000
Cleaning Instructions for Burner, Pilot Assembly, and Emitter Screen Series: 220000-450000 10 mm open end wrench 12 mm open end wrench 9/16 open end wrench 5/8 open end wrench 11/16 open end wrench 9/16
30" GAS RANGE INSTALLATION INSTRUCTIONS (For Models with Sealed Top Burners)
INSTALLATION AND SERVICE MUST BE PERFORMED BY A QUALIFIED INSTALLER. IMPORTANT: SAVE FOR LOCAL ELECTRICAL INSPECTOR'S USE. READ AND SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE. If the information in this
USE AND CARE MANUAL FOR OUTDOOR USE ONLY MADE IN THE U.S.A.
S o n o m a PLATINUM EDITION Sonoma Platinum Edition Grill: 27 Model TM USE AND CARE MANUAL FOR OUTDOOR USE ONLY MADE IN THE U.S.A. General Safety Instructions IMPORTANT SAFETY INFORMATION - Read this
INSTALLATION INSTRUCTIONS
INSTALLATION INSTRUCTIONS VGBQ SERIES CONVERSION KIT VIKING RANGE CORPORATION 111 Front Street Greenwood, Mississippi (MS) 38930 USA (662) 455-1200 IMPORTANT: PLEASE READ AND FOLLOW 1. Before beginning,
36G22, 36G23, 36G24 & 36G52 36J22, 36J23, 36J24 & 36J52 DSI and HSI Single Stage Combination Gas Valve
Operator: Save these instructions for future use! FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY BEFORE INSTALLING OR OPERATING THIS CONTROL COULD CAUSE PERSONAL INJURY AND/OR PROPERTY DAMAGE. DESCRIPTION
Name of Equipment Silver King Model SKMCD1P/C1. This equipment chapter is to be inserted in the appropriate section of the Equipment Manual.
Name of Equipment Silver King Model SKMCD1P/C1 This equipment chapter is to be inserted in the appropriate section of the Equipment Manual. Manufactured exclusively for McDonald s By Silver King Refrigeration,
Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.
Condensing Water Heater Operation Manual Model NPE-180A/ 210A/ 240A NPE-180S/ 210S/ 240S * Lead Free Keep this manual near this water heater for future reference whenever maintenance or service is required.
Tankless Water Heater
Tankless Water Heater USER S INFORMATION MANUAL Models WGRTNG199 / WGRTLP199 WGRTCNG199 / WGRTCLP199 NOTICE: Westinghouse reserves the right to make product changes or updates without notice and will not
USER MANUAL WARNING! CONTENTS MODEL 1 SPECIFICATIONS READ ALL INSTRUCTIONS BEFORE PROCEEDING. Non-Programmable Single Stage Heat/Cool Thermostat
Builder MODEL 1010 Series Non-Programmable Single Stage Heat/Cool Thermostat USER MANUAL Compatible with low voltage single stage gas, oil or electric heating or cooling systems, including single stage
Installation Instructions For Slider Casement Air Conditioners
Installation Instructions For Slider Casement Air Conditioners NOTE: These instructions describe installation in a typical wood framed window with a wood SLIDE-BY sash, or installation in a metal CASEMENT
Active and Passive Sash Replacement
for Andersen Gliding Windows Read all instructions carefully before attempting this procedure. If you have any questions about your ability to complete the procedure, call Andersen at 1-888-888-7020 for
Electrical Connection. Provide Proper Electrical Supply. Electrical Requirements. Connecting using the supplied cord and plug
Electrical Connection When installed the range must be electrically grounded in accordance with local codes or; in the absence of local codes with the National Electrical Code ANSI/NFPA 70, latest edition.
Sprinkler Identification Number. Page 1 of 6 MARCH 2014 TFP288. Worldwide Contacts. www.tyco-fire.com
Worldwide Contacts www.tyco-fire.com Model EC-HS 80 K-factor, Quick Response Extended Coverage Horizontal Sidewall Sprinklers Installations per VdS CEA 400, Annex E, LH/OH General Description The Model
Installation Operation & Maintenance Manual
www.montigo.com Operation & Maintenance Manual Check local codes and read all instructions prior to installation. EDVPV BF-Series Wall SS Power Gas Fireplace Vent System EDVPV47 EDVPV58 Warning: Improper
3 IN 1 BATHROOM HEATER
3 IN 1 BATHROOM HEATER MODEL NO.: A515 - SH MINI FUNCTION: HEATER, EXHAUST FAN AND LIGHT Dear customers, Thank you for selecting the AUPU 3 in 1 Bathroom Heater. Please read all instructions before commencing
HEAT WAVE DUCT KIT KIT # 946-568
HEAT WAVE DUCT KIT KIT # 946-568 www.regency-fire.com Approved for use with Models: P36, P36D, P42, P48, P90, P95, L676S, P33S & HZ54 WARNING: Improper installation, adjustment, alteration, service or
Cooling Capacity CFM range @.5 in. w.c. (125 Pa)
N8MXL Product Specifications 80% ECM Single Stage Heating Furnace EASIER TO SELL 80% AFUE Flame roll out sensors standard Category I venting Blocked vent switch 24 VAC humidifier terminal Electronic air
HEAVY DUTY STORAGE GAS
Multi-Fin flue technology Flue damper saves energy Electronic controls HEAVY DUTY STORAGE GAS Dependability The Rheem heavy duty gas range is the work horse of the industry having proved itself over many
Cooling Capacity CFM range @.5 in. w.c. (125 Pa)
96% AFUE, Single Stage, ECM Gas Furnace EASIER TO SELL 96% AFUE, all models all positions Xtra SEER ECM blower motor Supports two stage cooling units Dehumidification feature in cooling California NOx
OWNER S MANUAL DRAINVAC ATOMIK PRINTED APRIL 4-2011
OWNER S MANUAL th DRAINVAC ATOMIK PRINTED APRIL 4-2011 INTRODUCTION We take this opportunity to express our gratitude and extend our congratulations for your decision to purchase a Drainvac product. A
CHAPTER 10 BOILERS, WATER HEATERS AND PRESSURE VESSELS
CHAPTER 10 BOILERS, WATER HEATERS AND PRESSURE VESSELS SECTION 1001 GENERAL 1001.1 Scope. This chapter shall govern the installation, alteration and repair of boilers, water heaters and pressure vessels.
SECTION 23 81 03 - PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM
SECTION 23 81 03 - PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Packaged rooftop air conditioning unit (5 tons and smaller). 2. Roof curb. 1.2
Cooling Capacity CFM range @.5 in. w.c. (125 Pa)
96% AFUE, Two Stage ECM Gas Furnace EASIER TO SELL 96% AFUE, all models, all positions Two stage heating operation Xtra SEER ECM blower motor Supports two stage cooling units Dehumidification feature in
Convection TCO650. For your safety and continued enjoyment of this product, always read the instruction book carefully before using.
Convection Toaster Oven TCO650 For your safety and continued enjoyment of this product, always read the instruction book carefully before using. IMPORTANT SAFEGUARDS SAVE AND READ THESE INSTRUCTIONS When
Portable Air Conditioner
Portable Air Conditioner Owner's Manual Model:3 in 1 12,000 Btu/h Series 3 Please read this owner s manual carefully before operation and retain it for future reference. CONTENTS 1. SUMMARY...1 2. PORTABLE
Natural Gas Appliance Testing Action Guidelines (Non ESA/Low Income 5 )
Natural Gas Appliance Testing Action Guidelines (n ESA/Low Income 5 ) The purpose of these Action Guidelines is to describe the actions participating contractors and/or inspectors should take in the event
Ceiling Mount Air Handler Manual
www.surna.com 303.993.5271 Ceiling Mount Air Handler Manual Models: CMAH12, CMAH18, CMAH24, CMAH30, CMAH36, CMAH48, CMAH60 Revised: September 2014 Table of Contents Warranty Information 4 Limited Warranty
ALL WEATHER W-SERIES QUARTZ TUBE ELECTRIC INFRARED RADIANT HEATER INSTALLATION USE & CARE MANUAL
ALL WEATHER W-SERIES QUARTZ TUBE ELECTRIC INFRARED RADIANT HEATER TABLE OF CONTENTS: INSTALLATION USE & CARE MANUAL IMPORTANT INFORMATION Assembly Instructions 2 Wiring Instructions 2 Outdoor Installation
INSTALLATION & OPERATION MANUAL
INSTALLATION & OPERATION MANUAL GAS CONVECTION STEAMERS MODELS VSX5G, VSX5GC, VSX7GC & VSX10GC MODELS VSX 5G VSX5GC VSX7GC VSX10GC ML-114046 ML-114947 ML-114948 ML-114949 Model VSX10GC For additional information
Cleaning Instructions for Burner, Pilot Assembly, and Emitter Screen. Series: 150000 200605 LP Gas
Cleaning Instructions for Burner, Pilot Assembly, and Emitter Screen Series: 150000 200605 LP Gas Tools needed Bottle brush Non-abrasive scouring pad Small utility brush Heavy-duty pipe cleaners Air hose
STANDARD SPECIFICATIONS SECTION 02512 CLEANING AND LINING WATER MAINS
STANDARD SPECIFICATIONS SECTION 02512 CLEANING AND LINING WATER MAINS PART 1 GENERAL 1.1 DESCRIPTION A. Section includes requirements for cleaning and lining existing cast iron and ductile iron water mains
MODEL T200-F18 MODEL T125-F18 Finish Nailers
P MODEL T200-F18 MODEL T125-F18 Finish Nailers IMPORTANT! DO NOT DESTROY It is the customer s responsibility to have all operators and service personnel read and understand this manual. OPERATING MANUAL
Ceramic Glass Electric Galley Ranges
Ceramic Glass Electric Galley Ranges OWNER S MANUAL Models # 65335, 65336, 75331, 75332 Read all instructions and warnings before operating. Force 10 Manufacturing Corporation Unit A 19169 21 st Ave Surrey,
HOW MUCH FUEL DOES A GAS STOVE CONSUME AND HOW MUCH DOES IT COST TO OPERATE?
WHAT IS A BTU? The standard energy measurement is the BTU (British Thermal Unit). Each BTU unit is determined by the amount of thermal energy required to raise the temperature of one pound of water by
PREPIPED LIQUID FUEL MANIFOLDS PLPM
PREPIPED LIQUID FUEL MANIFOLDS PLPM INSTRUCTIONS WARNING These instructions are intended for use only by experienced, qualified combustion start-up personnel. Adjustment of this equipment and its components,
OUTDOOR GAS FIREPLACE USER GUIDE North America 630165_2 EF5000. www.escea.net
OUTDOOR GAS FIREPLACE USER GUIDE North America 630165_2 EF5000 www.escea.net Any service work carried out on this appliance must only be done by a recognised escea technician or authorized personnel. The
Instantaneous gas water heater
Instantaneous gas water heater Models W 125...T1 installation operation maintenance The Bosch instantaneous water heater is a high efficiency, space saving answer to your water heating needs. All Bosch
GNOME PELLET E.I. Pellet Heater Owner's Manual Installation and Operating Instructions. Please read this entire manual before installation.
Pellet Heater Owner's Manual Installation and Operating Instructions Please read this entire manual before installation. Save these instructions. SAFETY NOTICE HEATER MUST BE PROPERLY INSTALLED AND MAINTAINED
Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MF08CESWW. Voltage rating: 115V~60Hz Power rating : 800W
MODE ALARM Portable Air Conditioner OWNER S MANUAL Read these instructions before use 8 Model: MF08CESWW Voltage rating: 115V~60Hz Power rating : 800W Customer Support : 1-800-474-2147 For product inquiries
English. Symbols used to mark instructions...3. Congratulations...5 Getting the best results...5. Warnings...6 Operating Procedure...
2 Contents Components Attachments Guidance Installation Operation Maintenance Service Technical Troubleshooting Symbols used to mark instructions...3 Included Attachments...4 Congratulations...5 Getting
Instruction Manual for Residential Manufactured Home Gas Water Heaters
Instruction Manual for Residential Manufactured Home Gas Water Heaters FOR USE ONLY IN MANUFACTURED HOMES GAMA certification applies to all residential gas water heaters with capacities of 20 to 100 gallons