455 D Control Board. FAAC International Inc. West Coast Operations 357 South Acacia Avenue Unit 357 Fullerton, CA Tel.

Size: px
Start display at page:

Download "455 D Control Board. FAAC International Inc. West Coast Operations 357 South Acacia Avenue Unit 357 Fullerton, CA 92831 Tel."

Transcription

1 455 D Control Board FAAC International Inc. Headquarter & East Coast Operations 55 Sunbeam Road Suites 9 Jacksonville, FL 57 Tel FAAC International Inc. West Coast Operations 57 South Acacia Avenue Unit 57 Fullerton, CA 98 Tel

2 CONTENTS. 455 D CONTROL BOARD. Warnings.. Technical Specifications. Electric Connections D Layout and Components.5 Programming 7.6 StartUp 9.7 System Test 0. OPERATING MODES DETAILED DESCRIPTION. PREWIRED ENCLOSURE DIAGRAM 4. POWER AND ACCESSORIES CONNECTIONS 4 AC Power Wiring Guidelines 4 AC Power Connection 4 Magnetic Lock Connection 4 LIMITED WARRANTY 5 Read this instruction manual before you begin installing product. = Information regarding personal safety and proper maintanence of product. = Information regarding product s characteristics or. Rev: 0 October 00

3 . 455 D CONTROL BOARD D Layout and Components. Warnings Important: Before attempting any work on control board (connections, maintenance, always turn off power. Power Supply 5 V~ ± 0% or 0 V~ 6% 0% 50/60 Hz Absorbed Power Motor Max. Load Accessories Max. Load Electric Lock Max. Load 0 W 800 W 0,5 A 5 VA Ambient Operating Temperature Range Protection Fuses (see Fig. A 4 F to F Function Logics: Semiautomatic / Automatic / Safety Devices / Stepped Semiautomatic / Stepped Automatic / Stepped Safety Devices / Semiautomatic B / Deadman C Opening/Closing Time Programmable (from 0 to 0 s Pause Time Please refer to Chapter 6 for AC power wiring guidelines.. Technical Specifications Closing Leaf Delay Opening Leaf Delay Thrust Force: Programmable (from 0 to 4 min. Programmable (from 0 to 4 min. s (can be excluded Adjustable on 50 levels for each motor Terminal Board Inputs: Open / Open Free Leaf / Stop / Limitswitch Opening Safety Devices / Closing Safety Devices / Power Supply Earth. Terminal Board Outputs: Flashing Lamp / Motors / 4 VDC Accessories Power Supply / 4 VDC IndicatorLight / Fail Safe / VAC Electric Lock Power Supply Programmable Functions: Logic / Pause Time / Thrust Force / Torque at Initial Thrust / Opening and Closing Leaf Delay / Reversing Stroke / OverPushing Stroke / IndicatorLight / PreFlashing / Electric Lock / Fail Safe / Safety Devices Logic / Assistance Request / Detection Time of Obstacle or Contact Point Learning Function: Simple or complete work time learning, with or without Limitswitch and/or Gatecoder. J J F PE N L MAIN F J COM OP M COM M OP CL LAMP J4 F J F OP_A STOP OP_B J CL OP A B CL OP TX STP 4V DL DL SIGNALLING AND PROGRAMMING DISPLAY J LOW VOLTAGE TERMINAL BLOCK J CONNECTOR FOR RP RECEIVER J AC POWER SUPPLY TERMINAL BLOCK FCA FCA F F FCC FCC J5 J5 J FCA FCC J6 FCA J Figure A J4 MOTORS AND FLASHING LAMP CONNECTION TERMINAL BLOCK J5 INDICATORLIGHT AND ELECTRIC LOCK TERMINAL BLOCK J6 LIMITSWITCH AND GATECODER TERMINAL BLOCK F MOTORS AND TRANSFORMER PRIMARY WINDING FUSE (F 5A 0V (F 0A 5V F LOW VOLTAGE AND ACCESSORIES FUSE (T 800mA F F PROGRAMMING PUSHBUTTON PROGRAMMING PUSHBUTTON PROGRAMMING PUSHBUTTON FCC. Electric Connections BLUE BLUE FCC VAC MAX. 60W 4 VDC W 0 VAC 50 Hz or 5 VAC 60 Hz A B STOP For connection of photocells and safety devices, see Section.4.. VAC LIMITSWITCH OR GATECODER NB: Capacitors are supplied with operator. Figure B

4 .4. Connection of Photocells and Safety Devices Before connecting photocells (or or devices, it is advisable to select type of according to movement area y have to protect (see Fig.C: Opening Safety Devices: They operate only during gate opening movement and, refore, are suitable for protecting area between opening leaves and fixed obstacles (walls, etc against risk of impact and crushing. Opening/Closing Safety Devices NOTE: All safety devices must be connected using NORMALLY CLOSED outputs. Closing Safety Devices: They operate only during gate closing movement and, refore, y are suitable for protecting closing area against risk of impact. Opening/Closing Safety Devices: They operate during gate opening and closing movements and, refore, y are suitable for opening and closing areas against risk of impact. FAAC recommends use of layout in Fig. D (in event of fixed obstacles at opening or in Fig. E (no fixed obstacles. N.B. If two or more devices have same function (opening or closing, y should be connected to each or in series (see Fig. L. Connection of ONE Pair of Closing Photocells and ONE Pair of Opening/Closing Photocells (Recommended Layout A B STP CL OP TX 4V 0 Figure C Closing Safety Devices A B STP CL OP TX 4V Opening Safety Devices Connection of ONE Pair of Closing Photocells, ONE Pair of Opening Photocells and ONE Pair of Opening/Closing Photocells (Recommended Layout 0 TX RX CL 4 5 TX OP/CL TX CL RX OP/CL 4 5 TX RX CL 4 5 TX CL TX Connection of ONE Closing Safety Device and ONE Opening Safety Device Figure E TX TX OP/CL RX OP/CL A B STP CL OP TX 4V 0 Figure F Connection of NO Safety Devices RX OP 4 5 TX OP TX A B STP CL OP TX 4V 0 Figure D Figure G 4

5 Connection of ONE Pair of Opening Photocells Connection of TWO Pairs of Closing Photocells A B STP CL OP TX 4V A B STP CL OP TX 4V 0 Figure H RX OP 4 5 TX OP TX RX CL 4 5 TX CL TX Connection of ONE Pair of Closing Photocells A B STP CL OP TX 4V 0 TX TX CL RX CL 4 5 Figure K RX CL 4 5 TX CL TX Connection of TWO N.C. Contacts in Series (e.g. Photocells, Stop Figure I Figure L Connection of ONE Pair of Opening Photocells and ONE Pair of Closing Photocells Connection of TWO N.O. Contacts in Parallel (e.g. Open A, Open B A B STP CL OP TX 4V 0 TX RX OP 4 5 TX CL TX OP RX CL 4 5 TX.4. Terminal Block J Power Supply (Fig. B PE: Earth Connection / Ground N: AC V~ power supply (Neutral L: AC V~ power supply (Line NB: For correct, board must be properly grounded. Figure M.4. Terminal Block J4 Motors and Flashing Lamp M: COM / OP / CL: Connection to Motor Can be used in single configuration M: COM / OP / CL: Connection to Motor Cannot be used in single configurations Figure J LAMP: Flashing lamp output ( AC V ~ 5

6 .4.4 Terminal Block J Accessories (Fig. B A Total Opening Command (N.O.: Any pulse generator (pushbutton, detector, etc. which, by closing a contact, commands opening and/or closing of both gate leaves. To install several full opening pulse generators, connect N.O. contacts in parallel. B Partial Opening Command (N.O. / Closing: Any pulse generator (pushbutton, detector, etc. which, by closing a contact, commands opening and/or closing of driven by motor M. In B and C logics, it always commands closing of both leaves. To install several partial opening pulse generators, connect N.O. contacts in parallel. STP STOP Contact (N.C.: Any device (e.g. a pushbutton which, by opening a contact, is able to stop gate movement. To install several STOP devices, connect N.C. contacts in series. NB: If STOP devices are not connected, jumper connect STP terminals and. CL Closing Safety Devices Contact (N.C.: The purpose of closing safety devices is to protect movement area during closing. During closing, in EASEPAPSP logics, safety devices reverse movement of gate leaves, or stop and reverse movement when y are released (see Advanced Programming in Section.5.. During closing cycle in logics B and C, y interrupt movement. They never operate during opening cycle. If closing safety devices operate when gate is open, y prevent closing movement..4.6 Connector J Rapid Connection to RP Receivers This is used for rapid connection to RP receivers (see Fig. Q. Connect accessory with components side facing inside of card. Insert and remove with power OFF. Figure Q 455 D RP 48 RP 4 RC NB: If no closing safety devices are connected, jumper connect terminals CL and TX (Fig. G. OP Opening safety devices contact (N.C.: The purpose of opening safety devices is to protect movement area during opening. During opening, in EASEPAPSP logics, safety devices reverse movement of gate leaves. During opening cycle in logics B and C, y interrupt movement. They never operate during closing cycle. If opening safety devices operate when gate is closed, y prevent opening movement. NB: If no opening safety devices are connected, jumper connect inputs OP and TX (Fig. G. Negative for power supply to accessories 4 VDC Positive for power supply to accessories Important: Accessories max. load is 500 ma. To calculate current draw, refer to instructions for individual accessories. TX Negative for power supply to photocell transmitters. If you use this terminal for connecting negative for supplying power to photocell transmitters, you may, if necessary, also use FAIL SAFE function (see Advanced Programming in Section.5.. If this function is enabled, equipment checks of photocells before each opening or closing cycle..4.5 Terminal Block J5 IndicatorLight and Electric Lock W.L. Power supply to indicatorlight Connect a 4 VDC W max. indicatorlight, if necessary, between this terminal and 4V supply. To avoid compromising correct of system, do not exceed indicated power. LOCK Power supply to electric lock If necessary, connect a VAC electric strike lock between this terminal and 4V power supply. Please refer to Chapter 6 for Magnetic Lock connection. 6

7 .4.7 Terminal Block J6 LimitSwitch or Gatecoder These inputs are designed for connection of opening and closing limitswitches or Gatecoders The 400 operator cannot use limit switches but only Gatecoders. They are used to detect s angular position and to thus obtain deceleration and stop positions more accurately than using operating timing. Please refer to Figure S for wiring information. If Gatecoders are not used J6 inputs can be left unconnected. Figure S RED BLACK RED BLACK.4.8 Operating Logics WHITE WHITE This is a brief description of main operating logics of system. For a complete description please refer to Table A (automatic: The gate opens on command and automatically closes after a pause phase. A second command while opening is ignored; a second command during pause phase interrupts pause time; a second command during closing reopens gate. A maintained open command will hold gate open. S (security: The security mode is like A logic except that a second command during opening immediately closes gate. A maintained open command will not hold gate open. E (semiautomatic: This mode requires a second command during opening stops gate. A second command during closing reopens gate. EP (semiautomatic, step by step: This mode requires a command to open and a command to close. A second command during opening or closing causes gate to stop. A third command n reverses previous motion of gate. B (manned, pulsed: This mode is designed for guard station use and requires a three button switch (pulsed to open, close, and stop gate. C (manned and constant: This mode requires constant pressure switches. One to open and one to close. No pressure on a switch stops gate. FCC.5 Programming To program 455D Control Board, you have to access PRO GRAMMING mode. Programming is split into two parts: BASIC and ADVANCED..5. Basic Programming To access BASIC PROGRAMMING, press key F: Press and hold F, unit will display name of first function / parameter. When you release key, unit will display parameter s current value. Value can be modified with keys and. Press and hold F again, unit will display name of next function / parameter. When you reach last function, press F to exit program, display resumes monitoring input status. The following table displays sequence of functions accessible in BASIC PROGRAMMING: BASIC PROGRAMMING PAUSE TIME: = Semiautomatic = Automatic = Safety Automatic = Stepped Semiautomatic = Stepped Automatic = Safety Stepped Automatic = B Semiautomatic = Deadman LEAF FORCE: Adjusts thrust of Motor. press Display Function Default OPERATING LOGICS (see tab. /a h: This has effect only when automatic logic is selected. Adjustable from to secs. in onesecond increments. Subsequently, display changes to minutes and tenths of seconds (separated by a decimal point, time is adjusted in 0second increments, up to minutes max. Thus, if unit displays Time is mins. and 50 secs. = minimum force = maximum force (hydraulic LEAF FORCE: Adjusts thrust of Motor. = minimum force = maximum force (hydraulic F, Pause LEAF CLOSING DELAY: Delays closing start of with respect to. Adjustable from to minutes (see Pause Time. TIME LEARNING (see Section F..: Enables selection between simple (automatic learning and complete (manual choice of deceleration and stop points learning. Simple Learning: Complete Learning: s. > s. Exit from programming and return to inputs status monitoring. If using hydraulic operators, set force to maximum level. 7

8 .5. Advanced Programming To access ADVANCED PROGRAMMING, press and hold key F and n press key : Release key, unit displays name of first function. Release key F, modify value of function with keys and. Press and hold key F, unit displays name of next function, and if you release it, value that can be modified with keys and. When you reach last function, press F to exit program, unit resumes monitoring input status. The following table shows sequence of functions accessible in ADVANCED PROGRAMMING: ADVANCED PROGRAMMING MAXIMUM TORQUE AT INITIAL THRUST: F Display Function Default The motors operate at maximum torque (ignoring torque setting at start of movement. Useful for heavy leaves. LAST STROKE AT CLOSING: The motors are activated at full speed for second to facilitate locking of electric lock. = Active =Disabled REVERSING STROKE: Before opening, while gate is closed, motors thrust to close for seconds thus facilitating release of electric lock. LEAF ING DELAY ( s: Enables delayed start (at opening of, avoiding interference between leaves. FAIL SAFE: If this function is activated, it enables a function test of photocells before any gate movement. If test fails (photocells not serviceable, gate does not start movement. PREFLASHING (5 s: Activates flashing lamp for 5 seconds before start of movement. ELECTRIC LOCK ON LEAF : For using electric lock on instead of on. NB: Parameter modifications take effect immediately. Exit out of programming to save changes. If equipment is powered down before returning to normal status monitoring, any unsaved modifications will be lost. To restore programming defaults, press and hold three buttons,, F simultaneously for 5 seconds. Display Function Default INDICATORLIGHT: If is selected, output functions as a standard indicatorlight (lighted at opening and pause, flashing at closing, and off when gate is closed. Different figures correspond to extra time compared to normal work time (opening or closing when output can be used via a relay to power a courtesy light. Time can be adjusted from to sec. in sec. steps, and from to min. in 0 sec. steps. = Standard indicatorlight from to = Timed output CLOSING PHOTOCELLS REVERSE AT RELEASE: Enable this function if you want closing photocells to stop movement and reverse at release. Default setting is immediate reverse. A.D.M.A.P. FUNCTION: When enabled, safety devices operate in compliance with French standard NFP 5/6. ASSISTANCE REQUEST (combined with next function: If activated, at end of countdown (settable with next function i.e. Cycle programming it affects 8 s of preflashing at every Open pulse (job request. Can be useful for setting scheduled maintenance jobs. CYCLE PROGRAMMING: For setting countdown of system cycles. Settable (in thousands from to thousand cycles. The displayed value is updated as cycles proceed. This function can be used to check use of board or to exploit Assistance request. ANTICRUSHING SENSITIVITY: When operating with gatecoder, it controls anticrushing sensitivity. = Low = High. EXTRA WORK TIME: When operating without a gatecoder and limitswitch, if reversing occurs, and if does not reach its end contact point, you can activate this function to increase work time. Exit from programming and return to inputs status monitoring. 8

9 .6 StartUp.6. LED Check The board has a twodigit display. When not in PROGRAMMING mode, this display is used to indicate status of inputs. Fig. U shows how LED segments of display exactly correspond to inputs. Figure U The table below shows status of LEDs in relation to status of inputs. Note following: LED ON = closed contact LED OFF = open contact Operation of Status Signaling LEDs LEDs ON OFF OP_A Command activated Command inactive OP_B Command activated Command inactive STOP Command inactive Command activated CL Safety devices clear Safety devices triggered OP Safety devices clear Safety devices triggered FCA (if used FCC (if used FCC (if used FCA (if used The status of LEDs while gate is closed at rest are shown in bold.. Program functions of 455 D control board according to need, as previously shown.. Cut power to electronic control equipment.. Release operators and manually move gate to midpoint of opening angle. 4. Relock operators. 5. Restore power. Flashes when Gatecoder is in use Flashes when Gatecoder is in use Flashes when Gatecoder is in use Flashes when Gatecoder is in use.6. Rotation Direction and Force Check 6. Send and opening command on A input (Fig.B and check if gate leaves are being commanded to open. N.B: If first A pulse commands a closing, cut power and reverse phases of electric motor (red and black wires on 455 D control board. 7. Check force setting of motors, modify if necessary (see Section.5.. N.B: For hydraulic operators, like 400, force should be programmed to maximum level (50 8. Stop movement with a STOP command. 9. Release operators, close leaves and relock operators. Make sure travel limit mechanical stops are present. WARNING: During learning procedure, safety devices are disabled! Avoid crossing movement area when this is carried out..6. Learning Operating Times Opening/closing time is established by a learning procedure which varies slightly according to wher you are using Gatecoders or not..6.. LEARNING NORMAL TIMES Normal learning (i.e. without limitswitches and Gatecoders can be accomplished in two ways: SIMPLE LEARNING (Without Slow Down: Check that leaves are closed. Enter BASIC PROGRAMMING, select TIME LEARNING function and n press pushbutton for second. The display begins flashing and leaves begin to open. As soon as leaves reach opening contact point, provide an A pulse (with key operated pushbutton or with radio control to stop movement. The leaves stop and display stops flashing. Press pushbutton F to exit and save programming. The procedure is complete and gate is ready to operate. COMPLETE LEARNING (With Slow Down: Check that leaves are closed. Enter BASIC PROGRAMMING, select TIME LEARNING function and n press pushbutton for more than seconds. The display begins flashing and begins to open. The following functions can be performed by sending A pulses (by key pushbutton or radio control: Slow down at opening of Leaf stops at opening and begins its opening movement Slow down at opening of 4 Leaf stops at opening and immediately begins its closing movement 5 Slow down at closing of 6 Leaf stops at closing and begins its closing movement 7 Slow down at closing of 8 Leaf stops at closing When display stops flashing, press pushbutton F to exit and save programming. The procedure is complete and gate is ready to operate. Notes: If you wish to eliminate deceleration in certain stages, wait for to reach its stoplimit and supply consecutive Open pulses (by second. If only one is present, entire sequence must neverless be effected. When has finished opening, supply 5 Open pulses until begins to close, and n resume normal..6.4 Learning Times with Gatecoder Learning with Gatecoder can be accomplished in two ways: SIMPLE LEARNING (With Slow Down: Check that leaves are closed. Access BASIC PROGRAM MING, select TIME LEARNING function and n press pushbutton for second: display begins flashing and leaves begin opening movement. The movement stops automatically when opening stop limit is reached. The display will stop flashing. Press pushbutton F to exit and save programming. The procedure is complete and gate is ready to operate, using default slow down set at factory. COMPLETE LEARNING (With Slow Down: Check that leaves are closed. Access BASIC PROGRAM MING, select TIME LEARNING function and n press pushbutton for more than seconds. The display begins flashing and begins to open. The following functions can be performed by sending A pulses (by radio control or key pushbutton: 9

10 Leaf slows down at opening (it stops automatically on reaching stop limit Leaf opening movement begins Leaf slows down at opening (it stops automatically on reaching stop limit 4 Leaf closing movement begins 5 Leaf slows down at closing (it stops automatically on reaching stop limit 6 Leaf closing movement begins 7 Leaf slows down at closing (it stops automatically on reaching stop limit 8 End of learning When display stops flashing, press pushbutton F to exit and save programming. The procedure is complete and gate is ready to operate. Notes: The slow down pulse should be given before gate reaches positive stop to prevent from hitting it at full speed (it would be mistaken for an obstacle. If only one is present, entire sequence must neverless be effected. When has finished opening, supply 5 Open pulses until begins to close, and n resume normal..7 System Test When you are finished programming, test system. Verify that entire system operates correctly. Most importantly, check that force is adequately adjusted and that safety devices are operating correctly. 0

11 . OPERATING MODES DETAILED DESCRIPTION Tab. /a L ogic "E" PULSE S G ATE STATUS O PEN A O PEN B S TO P O PEN IN G SA FETY DEVIC E S C LO SIN G SA FETY DEVIC E S O P/C L SA FETY DEVIC E C LO SED f O pens lea O pens single lea f O PEN Recloses im m ediately ( (if on part.opng. O PEN A disabled ( C LO SIN G y Reopens im m ediatel N o (saves effect O PEN see paragraph 5.. Locks and, on release, open reverses to O PEN IN G S tops ( R everses to clos e N o effec t Locks and, on release, continues opening LO C KED C loses (w ith C losing Safety devices engaged, opens at nd pulse ( Tab. /b L ogic "A " PULSE S G ATE STATUS O PEN A O PEN B S TO P O PEN IN G SA FETY DEVIC E S C LO SIN G SA FETY DEVIC E S O P/C L SA FETY DEVIC E C LO SED O pens and closes it after pause tim e ( O pens single and closes after pause tim e ( O PEN on PA USE Reloads pause tim e (( Reloads pause tim e ( ( (if on part.opng. O PEN A disabled Reloads pause tim e ( C LO SIN G Reopens im m ediately ( N o (saves effect O PEN see paragraph 5.. Locks and, on release, open reverses to O PEN IN G L O C KED ( ( R everses to clos e N o effec t C loses ( Locks and, on release, continues opening Tab. /c L ogic "S" PULSE S G ATE STATUS O PEN A O PEN B S TO P O PEN IN G SA FETY DEVIC E S C LO SIN G SA FETY DEVIC E S O P/C L SA FETY DEVIC E C LO SED O pens and closes O pens it after pause tim e single and closes after pause tim e O PEN on PA USE Recloses im m ediately ( O n (if on part.opng. O PEN A disabled release, closes after 5" (O PEN O n disabled ( release, closes after 5" C LO SIN G y Reopens im m ediatel N o (saves effect O PEN see paragraph 5.. Locks and, on release, open reverses to O PEN IN G R ecloses im m ediately ( Reverses to clos e Locks and, (saves O PEN on release, continues opening L O C KED C loses ( O PEN disabled Tab. /d Logic "EP" PULSES GATE STATUS A B STOP ING SAFETY DEVICES CLOSING SAFETY DEVICES OP/CL SAFETY DEVICE CLOSED Opens Opens for partial opening time No effect No effect No effect ( disabled ( disabled Recloses immediately ( No effect (if on part.opng. A No effect ( disabled ( No effect ( disabled disabled CLOSING No effect (saves see paragraph 5.. Locks and, on release, reverses to open ING ( see paragraph 5.. No effect Locks and, on release, continues opening LOCKED Restarts movement in reverse direction ( (always closes after a Stop No effect ( disabled No effect (if it must open, it disables No effect No effect ( disabled (if it must close, it disables ( If maintained, it prolongs pause until disabled by command (timer function ( If anew pulse occurs within seconds after reversing, it immediately stops. ( During partial opening cycle, an Apulse causes total opening. NB.: Effects on or active pulse inputs in brackets.

12 Tab. /e L ogic "A P" PULSE S G ATE STATUS O PEN A O PEN B S TO P O PEN IN G SA FETY DEVIC E S C LO SIN G SA FETY DEVIC E S O P/C L SA FETY DEVIC E C LO SED O pens and closes O pens it after pause tim e single and closes after pause tim e O PEN on PA USE ( (if on part.opng. O PEN A disabled Reloads pause tim e ( Reloads pause tim e C LO SIN G y Reopens im m ediatel N o (saves effect O PEN see paragraph 5.. Locks and, on release, open reverses to O PEN IN G S tops ( R everses to clos e N o effec t Locks and, on release, continues opening LO C KED C loses (w ith C losing Safety devices engaged, opens at nd pulse ( Tab. /f L ogic "SP" PULSE S G ATE STATUS O PEN A O PEN B S TO P O PEN IN G SA FETY DEVIC E S C LO SIN G SA FETY DEVIC E S O P/C L SA FETY DEVIC E C LO SED O pens and closes O pens it after pause tim e single and closes after pause tim e O PEN on PA USE ( O n (if on part.opng. O PEN A disabled release, closes after 5" (O PEN O n disabled ( release, closes after 5" C LO SIN G y Reopens im m ediatel N o (saves effect O PEN see paragraph 5.. Locks and, on release, open reverses to O PEN IN G S tops ( Reverses to clos e Locks and, (saves O PEN on release, continues opening L O C KED C loses ( O PEN disabled Tab. /g L ogic "B" PULSE S G ATE STATUS O PEN A (opening O PEN B (closing S TO P O PEN IN G SA FETY DEVIC E S C LO SIN G SA FETY DEVIC E S O P/C L SA FETY DEVIC E C LO SED f O pens lea N o effec t (O PEN A disabled (O PEN A disabled O PEN t N o effec C loses lea f (O PEN B disabled (O PEN B disabled (O PEN B disabled C LO SIN G n O PEN IN G t R everses to ope N o effec t N o effec N o effec t N o (saves (O PEN A effect O PEN A disabled ( O PEN B disabled operatio n (O PEN A /B disabled L O C KED f O pens lea C loses lea f ( A/B disabled (O PEN A disabled (O PEN B disabled (O PEN A /B disabled Tab. /h L ogic "C " C O N TRO LS A LWAYS HELD DO W N PULSE S G ATE STATUS O PEN A (opening O PEN B (closing S TO P O PEN IN G SA FETY DEVIC E S C LO SIN G SA FETY DEVIC E S O P/C L SA FETY DEVIC E C LO SED f O pens lea (O PEN A disabled (O PEN A disabled (O PEN A disabled O PEN C loses (O PEN B disabled (A/B disabled (O PEN A disabled (O PEN B disabled (O PEN B disabled C LO SIN G n S tops operatio / O PEN IN G / n operatio (O PEN A disabled ( O PEN B disabled operatio n (O PEN A /B disabled ( If maintained, it prolongs pause until disabled by command (timer function ( If anew pulse occurs within seconds after reversing, it immediately stops. ( During partial opening cycle, an Apulse causes total opening. NB.: Effects on or active pulse inputs in brackets.

13 . PREWIRED ENCLOSURE DIAGRAM 455 D Contr ol Boa r d

14 4. POWER AND ACCESSORIES CONNECTIONS AC Power Wiring Guidelines. Check local wiring codes in all cases and follow all local building codes. Wiring and hookup should be performed by qualified electricians/installers only.. AC power should be supplied from a circuit breaker panel and must have its own dedicated circuit breaker. This supply must include a green ground conductor.. Properly ground gate operator to minimize or prevent damage from power surges and/or lightning. Use a grounding rod if necessary. A surge suppressor is recommended for additional protection. Magnetic Lock Connection When connecting a magnetic lock to system, use Maglock Relay Kit (P/N: 5 and connect it as follows: AC Power Connection. Turn circuit breaker for AC gate operator power to OFF before connecting AC input wires.. Turn Power Switch located on left side of prewired enclosure to OFF before connecting AC input wires.. Connect AC input wires to AC terminal located on top left of enclosure. See diagram on right. 4

15 LIMITED WARRANTY To original purchaser only: FAAC International, Inc., warrants, for twentyfour (4 months from date of invoice, gate operator systems and or related systems and equipment manufactured by FAAC S.p.A. and distributed by FAAC International, Inc., to be free from defects in material and workmanship under normal use and service for which it was intended provided it has been properly installed and operated. FAAC International, Inc. s obligations under this warranty shall be limited to repair or exchange of any part of parts manufactured by FAAC S.p.A. and distributed by FAAC International, Inc. Defective products must be returned to FAAC International, Inc., freight prepaid by purchaser, within warranty period. Items returned will be repaired or replaced, at FAAC International, Inc. s option, upon an examination of product by FAAC International, Inc., which discloses, to satisfaction of FAAC International, Inc., that item is defective. FAAC International, Inc. will return warranted item freight prepaid. The products manufactured by FAAC S.p.A. and distributed by FAAC International, Inc., are not warranted to meet specific requirements, if any, of safety codes of any particular state, municipality, or or jurisdiction, and neir FAAC S.p.A. or FAAC International, Inc., assume any risk or liability whatsoever resulting from use reof, wher used singly or in combination with or machines or apparatus. Any products and parts not manufactured by FAAC S.p.A. and distributed by FAAC International, Inc., will carry only warranty, if any, of manufacturer. This warranty shall not apply to any products or parts reof which have been repaired or altered, without FAAC International, Inc. s written consent, outside of FAAC International, Inc. s workshop, or altered in any way so as, in judgment of FAAC International, Inc., to affect adversely stability or reliability of product(s or has been subject to misuse, negligence, or accident, or has not been operated in accordance with FAAC International, Inc. s or FAAC S.p.A. s instructions or has been operated under conditions more severe than, or orwise exceeding, those set forth in specifications for such product(s. Neir FAAC S.p.A. nor FAAC International, Inc., shall be liable for any loss or damage whatsoever resulting, directly or indirectly, from use or loss of use of product(s. Without limiting foregoing, this exclusion from liability embraces a purchaser s expenses for downtime or for making up downtime, damages for which purchaser may be liable to or persons, damages to property, and injury to or death of any persons. FAAC S.p.A. or FAAC International, Inc., neir assumes nor authorizes any person to assume for m any or liability in connection with sale or use of products of FAAC S.p.A. or FAAC International, Inc. The warranty herein above set forth shall not be deemed to cover maintenance parts, including, but not limited to, hydraulic oil, filters, or like. No agreement to replace or repair shall constitute an admission by FAAC S.p.A. or FAAC International, Inc., of any legal responsibility to effect such replacement, to make such repair, or orwise. This limited warranty extends only to wholesale customers who buy directly through FAAC International, Inc. s normal distribution channels. FAAC International, Inc., does not warrant its products to end consumers. Consumers must inquire from ir selling dealer as to nature and extent of that dealer s warranty, if any. This warranty is expressly in lieu of all or warranties expressed or implied including warranties of merchantability and fitness for use. This warranty shall not apply to products or any part reof which have been subject to accident, negligence, alteration, abuse, or misuse or if damage was due to improper installation or use of improper power source, or if damage was caused by fire, flood, lightning, electrical power surge, explosion, wind storm, hail, aircraft or vehicles, vandalism, riot or civil commotion, or acts of God. 5

Hydraulic Swing Gate Operator

Hydraulic Swing Gate Operator 400 Hydraulic Swing Gate Operator UL35 Compliant FAAC International Inc. Headquarter & East Coast Operations 55 Sunbeam Road Suites 9 Jacksonville, FL 357 Tel. 866 95 3 www.faacusa.com FAAC International

More information

EC DECLARATION OF CONFORMITY FOR MACHINES

EC DECLARATION OF CONFORMITY FOR MACHINES EC DECLARATION OF CONFORMITY FOR MACHINES (DIRECTIVE 98/37/EC) Manufacturer: Address: Declares that: FAAC S.p.A. Via Benini, 1-40069 Zola Predosa BOLOGNA - ITALY 770 mod. operator is built to be integrated

More information

Underground Swing Gate Operator

Underground Swing Gate Operator 770 Underground Swing Gate Operator FAAC International Inc. Headquarter & East Coast Operations 5151 Sunbeam Road Suites 9-11 Jacksonville, FL 32257 Tel. 866 925 3222 www.faacusa.com FAAC International

More information

CONTENTS. 1. CE DECLARATION OF CONFORMITY FOR MACHINES pag.11. 2. DESCRIPTION pag.12. 3. TECHNICAL SPECIFICATIONS pag.13. 4. INSTALLATION pag.

CONTENTS. 1. CE DECLARATION OF CONFORMITY FOR MACHINES pag.11. 2. DESCRIPTION pag.12. 3. TECHNICAL SPECIFICATIONS pag.13. 4. INSTALLATION pag. CONTENTS 1. CE DECLARATION OF CONFORMITY FOR MACHINES pag.11. DESCRIPTION pag.1 3. TECHNICAL SPECIFICATIONS pag.13 4. INSTALLATION pag.13 5. TESTING THE AUTOMATED SYSTEM pag.19 6. MANUAL OPERATION pag.19

More information

Advantium 2 Plus Alarm

Advantium 2 Plus Alarm ADI 9510-B Advantium 2 Plus Alarm INSTALLATION AND OPERATING INSTRUCTIONS Carefully Read These Instructions Before Operating Carefully Read These Controls Corporation of America 1501 Harpers Road Virginia

More information

CONTENTS T HE 415 L LS OPERATOR AND 455 D CONTROL PANEL: I NSTALLATION MANUAL

CONTENTS T HE 415 L LS OPERATOR AND 455 D CONTROL PANEL: I NSTALLATION MANUAL T HE 415 L LS OPERATOR AND 455 D CONTROL PANEL: I NSTALLATION MANUAL May, 2006 455 D Control Panel Installation Manual CONTENTS Important Safety Information 2 Technical Data 4 Unpacking the Operator 5

More information

543-0032-00, 943-0032-00. User s Manual

543-0032-00, 943-0032-00. User s Manual 543-0032-00, 943-0032-00 User s Manual 1 Comfort Alert Diagnostics Faster Service And Improved Accuracy The Comfort Alert diagnostics module is a breakthrough innovation for troubleshooting heat pump and

More information

GENERATOR START CONTROL MODULE - MINI (2 Wire to 3 Wire)

GENERATOR START CONTROL MODULE - MINI (2 Wire to 3 Wire) FEATURES & APPLICATIONS Inexpensive 2 wire to 3 wire start controller for electric start high speed gas generators. Optimized for use with Outback Invertors. Supports three types of 3 wire generator control

More information

25 Code GTO Digital Keypad

25 Code GTO Digital Keypad 2 Code GTO Digital Keypad Instructions for Wired and Wireless Installations (FM1-G only) Thank you for purchasing the GTO Digital Keypad. Be sure to read the directions carefully and completely. Before

More information

Model SRMD Setra Remote Monitoring Display

Model SRMD Setra Remote Monitoring Display Model SRMD Setra Remote Monitoring Display 1.0 GENERAL INFORMATION Thank you for purchasing the Setra Remote Monitoring Display (SRMD). The SRMD is a digital panel meter with a bright 1 LED display for

More information

F4 PLUS. control MPS 120 - MPS 120E - MPS 160 - MPS 160E - MPS 240 - MPS 240E YES YES. 1 4 inputs Trimmers and DIP-switches YES

F4 PLUS. control MPS 120 - MPS 120E - MPS 160 - MPS 160E - MPS 240 - MPS 240E YES YES. 1 4 inputs Trimmers and DIP-switches YES CONTROL control F4 PLUS Anticrushing safety device To find out about the other functions, see the table on page 02 or 2 at 3W (maximum 700W) 220 TOP29 TOP39 TOP44 FLOOR80 BL230 ART5000 PASS220 PASS820

More information

RI-215A Operator s Manual. Part Number: 71-0045RK Revision 0 Released: 10/3/05

RI-215A Operator s Manual. Part Number: 71-0045RK Revision 0 Released: 10/3/05 RI-215A Operator s Manual Part Number: 71-0045RK Revision 0 Released: 10/3/05 Warranty RKI Instruments, Inc., warrants gas alarm equipment sold by us to be free from defects in materials and workmanship,

More information

D755M CONTROL CARD FOR TWO SINGLE-PHASE MOTORS 220/230 VAC TARJETA DE MANDO PARA DOS MOTORES MONOFÁSICOS 220/230 VAC INSTALLATION GUIDE

D755M CONTROL CARD FOR TWO SINGLE-PHASE MOTORS 220/230 VAC TARJETA DE MANDO PARA DOS MOTORES MONOFÁSICOS 220/230 VAC INSTALLATION GUIDE Distributed by: AFW Access Systems Phone: 305-691-7711 Fax: 305-693-1386 E-mail: sales@anchormiami.com D755M CONTROL CARD FOR TWO SINGLE-PHASE MOTORS 220/230 VAC TARJETA DE MANDO PARA DOS MOTORES MONOFÁSICOS

More information

CA-125 Owner's Manual

CA-125 Owner's Manual Remote Vehicle Control System CA-125 Owner's Manual Vehicle Security System With Remote Keyless Entry IMPORTANT NOTE: The operation of the Security and Convenience System as described in this manual is

More information

S450H. 24V Hydraulic Swing Gate Operator UL325 - UL991

S450H. 24V Hydraulic Swing Gate Operator UL325 - UL991 S450H 24V Hydraulic Swing Gate Operator UL325 - UL991 FAAC International Inc. Headquarter & East Coast Operations 5151 Sunbeam Road Suites 9-11 Jacksonville, FL 32257 Tel. (866) 925-3222 www.faacusa.com

More information

Master Time Clock MTC-200 MTC-400 MTC-600. Users Manual

Master Time Clock MTC-200 MTC-400 MTC-600. Users Manual Master Time Clock MTC-200 MTC-400 MTC-600 Users Manual Toll Free (888)713-0373 Phone (972)987-4408 FAX (877)720-9291 www.midwest-time.com sales@midwest-time.com TABLE OF CONTENTS TOPIC PAGE GENERAL DESCRIPTION

More information

OPL BASIC. Dosing System for Professional Laundry machines. Contents

OPL BASIC. Dosing System for Professional Laundry machines. Contents OPL BASIC Dosing System for Professional Laundry machines Contents 1 Getting Started. Page 2 2 Installation. Page 4 3 Set Up & Operation. Page 8 4 Maintenance & Accessories. Page 10 5 Troubleshooting Page

More information

Automatic Phone-Out Home Monitoring Systems

Automatic Phone-Out Home Monitoring Systems Automatic Phone-Out Home Monitoring Systems Power Outage and Freeze Alarm Model Number: THP202 Power Outage, Freeze and Flood Alarm Product Description Model Number: THP201 These monitoring systems are

More information

Water Leak Detection System

Water Leak Detection System Water Leak Detection System Installation and Operating Manual 505-334-5865 ph 505-334-5867 fax www.rodisystems.com email:info@rodisystems.com 936 Highway 516 Aztec, NM 87410-2828 Manual Revisions and Copyright

More information

CHAPTER 1. GETTING STARTED... 1

CHAPTER 1. GETTING STARTED... 1 REV. 01-2014 TABLE OF CONTENTS LIMITATION OF LIABILITY CHAPTER 1. GETTING STARTED... 1 1.1 Introduction... 1 1.2 System Descriptions... 1 1.3 System Applications... 1 1.4 System Specifications... 1 1.5

More information

Trilogy DL2700 Programming Instructions OI209A 2/04

Trilogy DL2700 Programming Instructions OI209A 2/04 345 Bayview Avenue Amityville, New York 11701 For Sales and Repairs 1-800-ALA-LOCK For Technical Service 1-800-645-9440 ALARM LOCK 2004 Trilogy DL2700 Programming Instructions OI209A 2/04 CONGRATULATIONS!

More information

NSI DDR DIMMING RACK POWER DISTRIBUTION UNIT

NSI DDR DIMMING RACK POWER DISTRIBUTION UNIT Main Power Connections NSI DDR DIMMING RACK POWER DISTRIBUTION UNIT Camlok style "J" series connectors are for connection of up to a 300 Amp 120/240 VAC or 120/208 VAC electrical service. These connections

More information

Owner s Guide. ca6554

Owner s Guide. ca6554 PROFESSIONAL SERIES Owner s Guide For Models: ca6554 Deluxe Vehicle Security and Remote Start System with 2 Way Confirming LCD Remote Control IMPORTANT NOTE: The operation of the Security and Convenience

More information

INSTALLATION/PROGRAMMING INSTRUCTIONS 928 ENTRYCHECK

INSTALLATION/PROGRAMMING INSTRUCTIONS 928 ENTRYCHECK 3580 Willow Lane, Westlake Village, CA 91361-4921 (805) 494-0622 Fax: (805) 494-8861 www.sdcsecurity.com E-mail: service@sdcsecurity.com INSTALLATION/PROGRAMMING INSTRUCTIONS 928 ENTRYCHECK INTRODUCTION

More information

INSTALLATION GUIDE. Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930

INSTALLATION GUIDE. Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930 INSTALLATION GUIDE Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930 Card Reader and Controller Model 3.5 with KIM Swipe Reader Table of Contents 1. Features..................................

More information

How To Control A Car Alarm On A Car With A Remote Control System

How To Control A Car Alarm On A Car With A Remote Control System MODEL CA100 REMOTE CONTROL AUTO ALARM SYSTEM INSTALLATION & OPERATION INSTRUCTIONS WIRING DIAGRAM Black Antenna Wire 6 Pin 6 Pin Mini Connector Valet Switch Blue LED Indicator Blue Wire: (-) 200mA Unlock

More information

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules.

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. Power Max Level 2 Charging Station en Installation and Operating Instructions This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the

More information

INSTALLER S & OWNER S MANUAL

INSTALLER S & OWNER S MANUAL INSTALLER S & OWNER S MANUAL HVAC INSTALLER: PLEASE LEAVE MANUAL FOR HOMEOWNER DEH 3000 DEH 3000 Part No. 4028539 Dehumidifier & Ventilation System Controller P.O. Box 8680 Madison, WI 53708 TOLL-FREE

More information

ALARM ANNUNCIATOR ME - 3010 INSTRUCTION MANUAL

ALARM ANNUNCIATOR ME - 3010 INSTRUCTION MANUAL ALARM ANNUNCIATOR ME - 3010 INSTRUCTION MANUAL INTRODUCTION... 2.. TECHNICAL DATA... 3 ACCESSORIES... 5. INSTALLATION... 7 OPERATION... 12. TECHNICAL INFORMATION... 13 MAINTENANCE... 14. CONFIGURATIONS...

More information

Installation and Operation Guide PD4600 Series Converter Replacement

Installation and Operation Guide PD4600 Series Converter Replacement Installation and Operation Guide PD4600 Series Converter Replacement Extended warranties are available for purchase at www.progressivedyn.com Member Thank you for selecting Progressive Dynamics as your

More information

BACnet Automation Interface Module (Network Version)

BACnet Automation Interface Module (Network Version) Sense +V Tx Rx LAN LINK Over ARCNET KBaud BACnet Rx BACnet Tx Archive Valid Port S Tx Port S Rx Low Battery Network- Enhanced Access Default MSTP PTP = Download Required on Rnet and Port S IP Address IP

More information

Installation and Operation Guide for PD5100 Automatic Transfer Switch

Installation and Operation Guide for PD5100 Automatic Transfer Switch Installation and Operation Guide for PD5100 Automatic Transfer Switch Member P r o gr e ssive Dynamics, Inc. 507 Industrial Rd Marshall, MI 49068 www.progressivedyn.com 2012 Progressive Dynamics, Inc.

More information

GSM Gate Opener GSM Remote Switch RTU5015 User Manual

GSM Gate Opener GSM Remote Switch RTU5015 User Manual GSM Gate, Barrier, Shutter, Garage Door and Door opener Open gate or garage door with a FREE call from your mobile phone! Remote switching machines with a FREE call from your mobile phone! GSM Gate Opener

More information

Button 1 Button 2. Button 3 Button 4. Programmed Remote Transmitter. Button Function Condition

Button 1 Button 2. Button 3 Button 4. Programmed Remote Transmitter. Button Function Condition WWW.STELLAR.COM ST9000 SECURITY SYSTEM Button Function Condition 1 a. Arm and lock doors b. Car finder with sound c. Temporary stop alarm from sounding d. Remote lock doors 1 for 2 sec. Panic Anytime a.

More information

PK5500 v1.1 Installation Instructions

PK5500 v1.1 Installation Instructions PK5500 v1.1 Installation Instructions 1 2 3 4 5 6 7 8 9 * 0 # WARNING: Please refer to the System Installation Manual for information on limitations regarding product use and function and information on

More information

CONTROL SWITCHER User s Manual (Preliminary)

CONTROL SWITCHER User s Manual (Preliminary) CONTROL SWITCHER User s Manual (Preliminary) www.voodoolab.com Copyright 2010 by Digital Music Corporation. This publication is protected by copyright and all rights are reserved. Voodoo Lab, Control Switcher,

More information

USER MANUAL WARNING! CONTENTS MODEL 1 SPECIFICATIONS READ ALL INSTRUCTIONS BEFORE PROCEEDING. Non-Programmable Single Stage Heat/Cool Thermostat

USER MANUAL WARNING! CONTENTS MODEL 1 SPECIFICATIONS READ ALL INSTRUCTIONS BEFORE PROCEEDING. Non-Programmable Single Stage Heat/Cool Thermostat Builder MODEL 1010 Series Non-Programmable Single Stage Heat/Cool Thermostat USER MANUAL Compatible with low voltage single stage gas, oil or electric heating or cooling systems, including single stage

More information

MANAGEMENT SOLUTION (P.A.M.S.)

MANAGEMENT SOLUTION (P.A.M.S.) DOORKING SYSTEMS ACCESS CONTROL SOLUTIONS PERIMETER ACCESS MANAGEMENT SOLUTION (P.A.M.S.) Revision N, updated 01.12 PERIMETER ACCESS MANAGEMENT SOLUTION (P.A.M.S.) Design Concept How the System Works TYPICAL

More information

OPERATING INSTRUCTIONS Model ST-888 DTMF ANI/ENI Display Decoder

OPERATING INSTRUCTIONS Model ST-888 DTMF ANI/ENI Display Decoder P R O D U C T G R O U P OPERATING INSTRUCTIONS Model ST-888 DTMF ANI/ENI Display Decoder Manual # 600-0901 November 30, 1999 Rev. D - 99068 DESCRIPTION The ST-888 Mobilecall Display Decoder is a desktop

More information

English AUTOMATION SYSTEMS FOR SLIDING GATES. Operating and installation instructions SLIDE SERIES

English AUTOMATION SYSTEMS FOR SLIDING GATES. Operating and installation instructions SLIDE SERIES English AUTOMATION SYSTEMS FOR SLIDING GATES Operating and installation instructions SLIDE SERIES v.0 Rev /202 INDEX ) General Safety Regulations... pág. 0 2) Description... pág. 02 3) Technical Specifications...

More information

AUTOMATIC TRANSFER SWITCH CONTROL UNIT OPERATOR S MANUAL

AUTOMATIC TRANSFER SWITCH CONTROL UNIT OPERATOR S MANUAL ATS-220 AUTOMATIC TRANSFER SWITCH CONTROL UNIT OPERATOR S MANUAL For Use in 208 to 240 Volts Single and 3 Phase ATS Systems With 110Volt AC or DC Control Motors and selenoids 4501 NW 27 ave Miami FL 33142

More information

INSTRUCTION MANUAL PC5OO WITH PC5OORK KEYPAD

INSTRUCTION MANUAL PC5OO WITH PC5OORK KEYPAD INSTRUCTION MANUAL PC5OO WITH PC5OORK KEYPAD TABLE OF CONTENTS SYSTEM INFORMATION 2 INTRODUCTION 3 Test Your System Regularly...3 Important Notice...3 Glossary...3 BASIC OPERATION 4 Arming Your System...4

More information

Car Alarm Series 2 B 2 Buttons

Car Alarm Series 2 B 2 Buttons Car Alarm Series 2 B 2 Buttons G22 SE (External - Shock Sensor) Version 3 Software 67 Plus www.geniuscaralarm.com 21 CAR ALARM GENIUS Series 2B 2 Buttons - G22 Se (External Shock Sensor) Module controlled

More information

User Manual. Humidity-Temperature Chart Recorder. Model RH520

User Manual. Humidity-Temperature Chart Recorder. Model RH520 User Manual Humidity-Temperature Chart Recorder Model RH520 Introduction Congratulations on your purchase of the Extech RH520 Temperature + Humidity Chart Recorder. The RH520 measures and displays Temperature,

More information

GSM Gate Opener GSM Remote Switch RTU5015. User Manual. Ver 1.3 Date Issued: 2010-08-18. All rights reserved by King Pigeon Hi-Tech. Co., Ltd.

GSM Gate Opener GSM Remote Switch RTU5015. User Manual. Ver 1.3 Date Issued: 2010-08-18. All rights reserved by King Pigeon Hi-Tech. Co., Ltd. GSM Gate, Barrier, Shutter, Garage Door and Door opener Open gate or garage door with a FREE call from your mobile phone! Remote switching machines with a FREE call from your mobile phone! GSM Gate Opener

More information

BroadBand PowerShield. User Manual

BroadBand PowerShield. User Manual BroadBand PowerShield User Manual 990-0375G 12/2006 Chapter 1 General Information The PowerShield provides a power source for broadband telephony and other DC applications. Safety This Safety Guide contains

More information

PAC1 Door Access Controller

PAC1 Door Access Controller PAC1 Door Access Controller Series 2 IMPORTANT DIFFERENCES FROM SERIES 1 1. A PACDL data logger revision 4.0 or higher attached to the DLOG terminal is able to program all features (i.e. times, relay type,

More information

ITC-BTTN Cellular Bluetooth Gateway. Owner s Manual 1

ITC-BTTN Cellular Bluetooth Gateway. Owner s Manual 1 ITC-BTTN Cellular Bluetooth Gateway Owner s Manual 1 2 Table of Contents Introduction...3 Package Contents...3 XLink Connections Diagram...4 Setup...5 Pairing your Bluetooth Cell Phone to the XLink...6

More information

FTW 175 VERIZON Wireless Monitoring System Reference Manual Part Number 7911751VERIZON

FTW 175 VERIZON Wireless Monitoring System Reference Manual Part Number 7911751VERIZON FTW 175 VERIZON Wireless Monitoring System Reference Manual Part Number 7911751VERIZON SERIAL NUMBER Flash Technology, 332 Nichol Mill Lane, Franklin, TN 37067 (615) 261-2000 Front Matter Abstract This

More information

A1000 Cheat Sheet (Open Loop Vector)

A1000 Cheat Sheet (Open Loop Vector) A1000 Cheat Sheet (Open Loop Vector) The following procedure is a supplement to supplied with this equipment and will guide the user in properly wiring the A1000 and. It will also show the user how to

More information

CMD-8000 rev. A COMMANDER SERIES REMOTE CONTROL ENTRY SYSTEM

CMD-8000 rev. A COMMANDER SERIES REMOTE CONTROL ENTRY SYSTEM INTRODUCTION CMD-8000 rev. A COMMANDER SERIES REMOTE CONTROL ENTRY SYSTEM Thank you for purchasing the CMD-8000 Commander from Dakota Digital. This, along with many other products that Dakota Digital has

More information

AGS. Owner's Manual. Xantrex Automatic Generator Start Control System

AGS. Owner's Manual. Xantrex Automatic Generator Start Control System AGS Owner's Manual Xantrex Automatic Generator Start Control System TABLE OF CONTENTS INTRODUCTION...3 Main Features...3 Safety Summary...3 THINGS YOU SHOULD KNOW...4 THEORY OF OPERATION...5 System...5

More information

ADEMCO 4500 Thermostat

ADEMCO 4500 Thermostat ADEMCO 4500 Thermostat User Guide N7972V1 5/05 Rev. A TABLE OF CONTENTS About the 4500 Thermostat...1 Saving Money on Energy Bills...1 The 4500 Thermostat Provides Comfort and Convenience...1 How the 4500

More information

LCD5500Z / PKP-LCD v3.x Installation Instructions

LCD5500Z / PKP-LCD v3.x Installation Instructions LCD5500Z / PKP-LCD v3.x Installation Instructions TM Introduction The LCD5500Z / PKP-LCD keypad displays system status using an LCD screen. The keypad can be used on PowerSeries security systems with up

More information

PRO PLM Installation Instructions

PRO PLM Installation Instructions PRO PLM Installation Instructions PROFESSIONAL INSTALLATION STRONGLY RECOMMENDED Installation Precautions: Roll down window to avoid locking keys in vehicle during installation Avoid mounting components

More information

AIM TECHNICAL MANUAL PATENT PENDING STOP REMEMBER TO ACTIVATE UNIT BEFORE TESTING. See page 9 for Activation Instructions

AIM TECHNICAL MANUAL PATENT PENDING STOP REMEMBER TO ACTIVATE UNIT BEFORE TESTING. See page 9 for Activation Instructions AIM TECHNICAL MANUAL AIM-1450HW HARDWIRE PATENT PENDING STOP REMEMBER TO ACTIVATE UNIT BEFORE TESTING See page 9 for Activation Instructions AIM Technical Manual - AIM 1450HW AIM-1450HW HARDWIRE ABOUT

More information

TCP/IP MODULE CA-ETHR-A INSTALLATION MANUAL

TCP/IP MODULE CA-ETHR-A INSTALLATION MANUAL TCP/IP MODULE CA-ETHR-A INSTALLATION MANUAL w w w. c d v g r o u p. c o m CA-ETHR-A: TCP/IP Module Installation Manual Page Table of Contents Introduction...5 Hardware Components... 6 Technical Specifications...

More information

Ford/Lincoln Remote Access Android User s Guide

Ford/Lincoln Remote Access Android User s Guide Ford/Lincoln Remote Access Android User s Guide Rev. - 2/26/13 P/N: 4280523 Table Of Contents Download the Remote Access Application...3 Launch the Remote Access Application...3 New Account Setup...3 Adding

More information

1 For All Non-Programmable Digital Thermostat

1 For All Non-Programmable Digital Thermostat OWNER'S MANUAL P/N P474-0100 1 For All Non-Programmable Digital Thermostat TOTALINE 68 Dual Setpoint Very easy to program Thermoglow Backlight No batteries required Auto-Changeover Locking Keypad Meets

More information

NIGHT ONE DAY KIT Universal automated system for shutters

NIGHT ONE DAY KIT Universal automated system for shutters NIGHT ONE DAY KIT Universal automated system for shutters night one day Kit Advantages for the user 1 2 3 4 5 7 8 9 Lets you easily control shutters from inside the home Considerable energy savings Lets

More information

Unattended Answering Device Instruction Manual

Unattended Answering Device Instruction Manual Model 3137B Unattended Answering Device Instruction Manual Monroe Electronics 100 Housel Ave Lyndonville NY 14098 800-821-6001 585-765-2254 fax: 585-765-9330 monroe-electronics.com Printed in USA Copyright

More information

AM/FM Emergency Weather Radio/Light With Hand Crank Back-Up Power

AM/FM Emergency Weather Radio/Light With Hand Crank Back-Up Power VEC173 ONE YEAR LIMITED WARRANTY PROGRAM This limited warranty program is the only one that applies to this product, and it sets forth all the responsibilities of Vector Manufacturing, regarding this product.

More information

Operating Instructions

Operating Instructions VMD202 Vehicle Motion Detector Operating Instructions CAUTIONS AND WARNINGS Never use the VMD202 as a safety reversing or presence detection system. The VMD202 requires that a vehicle be moving for detection.

More information

SingleNet Single Cable Control System

SingleNet Single Cable Control System Single Cable Control System Economical, Reliable and Expandable Two-Wire Single Cable System DRIP/MICRO IRRIGATION PRODUCTS Single Cable Control System System Manager or Irrigation Controller Controls

More information

Model 3000-51 20 SPDT Relays 90401460

Model 3000-51 20 SPDT Relays 90401460 Model 3000-51 20 SPDT Relays 90401460 Page 1 All technical data and specifications in this publication are subject to change without prior notice and do not represent a commitment on the part of Giga-tronics,

More information

PC Tab Security System INSTRUCTION MANUAL

PC Tab Security System INSTRUCTION MANUAL PC Tab Security System INSTRUCTION MANUAL This manual is intended as a Quick Start manual covering the basic functions that have been enabled on the alarm panel. The alarm panel is capable of extensive

More information

MDC151-024031 Series

MDC151-024031 Series MDC151-024031 Series 24V, 3A Brushless DC Controller User s Guide A N A H E I M A U T O M A T I O N 910 East Orangefair Lane, Anaheim, CA 92801 e-mail: info@anaheimautomation.com (714) 992-6990 fax: (714)

More information

Operating Instructions

Operating Instructions CS101 CarSense Vehicle Motion Detector Operating Instructions CAUTIONS AND WARNINGS Never use the CS101 as a safety reversing or presence detection system. The CS101 requires that a vehicle be moving for

More information

Installation and Operating Manual

Installation and Operating Manual Installation and Operating Manual XL-660 Digital Access Control Station Your Partner in Access Control summitaccesscontrol.com Contents Two-Year Limited Warranty 3 PARTS CHECKLIST 4 INTRODUCTION 5 INSTALLATION

More information

EC DECLARATION OF CONFORMITY FOR MACHINES WARNINGS FOR THE INSTALLER

EC DECLARATION OF CONFORMITY FOR MACHINES WARNINGS FOR THE INSTALLER EC DECLARATION OF CONFORMITY FOR MACHINES (DIRECTIVE 2006/42/EC) Manufacturer: Address: Declares that: FAAC S.p.A. Via Benini, 1-40069 Zola Predosa BOLOGNA - ITALY 740 / 741 mod. operator is built to be

More information

..OR How To Protect your 3-Phase Equipment Investment with 3-Phase Monitors from Time Mark...

..OR How To Protect your 3-Phase Equipment Investment with 3-Phase Monitors from Time Mark... ..OR How To Protect your 3-Phase Equipment Investment with 3-Phase Monitors from Time Mark... TIME MARK CORPORATION 11440 EAST PINE STREET TULSA, OK 74116 USA tel 918 438-1220 fax 918 437-7584 www.time-mark.com

More information

VEHICLE SECURITY SYSTEM G25/G20

VEHICLE SECURITY SYSTEM G25/G20 VEHICLE SECURITY SYSTEM G25/G20 Limited Lifetime Warranty This vehicle security system is warranted to the original purchaser, to be free from defects in material and workmanship. The manufacturer will

More information

CA 1050 Owner s Guide

CA 1050 Owner s Guide PROFESSIONAL SERIES CA 1050 Owner s Guide Vehicle Security and Keyless Entry System IMPORTANT NOTE: The operation of the Security and Convenience System as described in this manual is applicable to most

More information

e-ask electronic Access Security Keyless-entry

e-ask electronic Access Security Keyless-entry e-ask electronic Access Security Keyless-entry e-fob Keyless-entry entry System Full-Function Function Installation Manual FCC ID: TV2EFOB1 (UM20 ~ 22793-02) Table of Contents Introduction... 1 e-fob Operation

More information

INSTALLATION MANUAL VEHICLE SECURITY SYSTEM CE-SS200

INSTALLATION MANUAL VEHICLE SECURITY SYSTEM CE-SS200 INSTALLATION MANUAL VEHICLE SECURITY SYSTEM CE-SS200 FUSION CULTURE TABLE OF CONTENTS There s no point doing something if no one notices. We ve always believed the way to make things happen is by getting

More information

User s Information Guide R1A

User s Information Guide R1A HSC505-R Home Security Controller - User Manual Release R1a Pi HSC505 and Pi HSC505R Home Security Controller User s Information Guide R1A Page 1 QD Dynamics (Pty) Ltd reserves the right to make changes

More information

GPS 35 USB. installation and quick start guide

GPS 35 USB. installation and quick start guide GPS 35 USB installation and quick start guide 2001 GARMIN Corporation GARMIN International, Inc. 1200 E 151 st Street, Olathe, Kansas 66062 U.S.A. Tel. 913/397.8200 Fax. 913/397.8282 GARMIN (Europe) Ltd.

More information

How to read this guide

How to read this guide How to read this guide The following shows the symbols used in this Quick start guide with descriptions and examples. Symbol Description Example P oint Reference Caution [ ] This symbol explains information

More information

Ford/Lincoln Remote Access iphone User s Guide

Ford/Lincoln Remote Access iphone User s Guide Ford/Lincoln Remote Access iphone User s Guide Rev. - 2/27/13 P/N: 4280522 Table Of Contents Download the Remote Access Application...3 Launch the Remote Access Application...3 New Account Setup...3 Adding

More information

HORNET Remote Control Systems

HORNET Remote Control Systems HORNET Remote Control Systems Up to 100metres Range 1 3 Button versions 12-30Vdc 0r 230Vac versions Reliable FM Technology Up to four 1000W Relay switches Waterproof Receiver (IP68) Momentary or Latching

More information

Manual for Fire Suppression & Methane Detection System

Manual for Fire Suppression & Methane Detection System Manual for Fire Suppression & Methane Detection System Fogmaker North America Post address: 150 Gordon Dr Exton, PA 19341 Delivery address: 150 Gordon Dr Exton, PA 19341 Tel: 610-265-3610 Fax: 610-265-8327

More information

Load Cell Amplifier Module. Instruction Manual LCA210-000

Load Cell Amplifier Module. Instruction Manual LCA210-000 Load Cell Amplifier Module Instruction Manual LCA210-000 Table of Contents 1. General Description...3 2. Specifications...3 2.1 Electrical...3 2.2 Physical...4 3. Installation...4 3.1 Wiring Guidelines...4

More information

EKP1 LED KEYPAD. Owner's Manual. Use with AV9000 & SC800/1600 Series Control panel

EKP1 LED KEYPAD. Owner's Manual. Use with AV9000 & SC800/1600 Series Control panel EKP1 LED KEYPAD Owner's Manual Use with AV9000 & SC800/1600 Series Control panel IT IS IMPORTANT FOR YOUR SAFETY TO TEST YOUR SYSTEM AND IT'S COMPONENTS REGULARLY. P/N 64812816 A PDF 10/24/97 Table of

More information

INSTRUCTION MANUAL MODEL PCD-88

INSTRUCTION MANUAL MODEL PCD-88 INSTRUCTION MANUAL MODEL PCD-88 CLOSED CAPTION DECODER LINK ELECTRONICS, INC. 2137 Rust Avenue Cape Girardeau, Missouri 63703 Phone: 573-334-4433 Fax: 573-334-9255 e-mail: sales @ linkelectronics.com website:

More information

1 ELGOTEAM ADVANCED SECURITY SYSTEMS Bi-directional spike barrier. Bi-directional spike barrier Customer Information packet

1 ELGOTEAM ADVANCED SECURITY SYSTEMS Bi-directional spike barrier. Bi-directional spike barrier Customer Information packet 1 Customer Information packet For more information: info@elgoteam.com www.elgoteam.com 2 Chapter contents Subject Page number The company 3 Background 4 Applications 5 Advantages 6 Operating positions

More information

Temperature & Humidity SMS Alert Controller

Temperature & Humidity SMS Alert Controller Temperature & Humidity SMS Alert Controller Version 7 [Windows XP/Vista/7] GSMS THR / GSMS THP Revision 110507 [Version 2.2.14A] ~ 1 ~ SMS Alarm Messenger Version 7 [Windows XP/Vista/7] SMS Pro series

More information

Directed Passive Keyless Entry System (PKE) Model 2102T Owner s Guide

Directed Passive Keyless Entry System (PKE) Model 2102T Owner s Guide Directed Passive Keyless Entry System (PKE) Model 2102T Owner s Guide 2012 Directed, Vista, CA G2102T Contents Government regulations...4 Warning! Safety first...6 Important information...6 System maintenance...6

More information

CMD-9000 COMMANDER SERIES REMOTE CONTROL ENTRY SYSTEM

CMD-9000 COMMANDER SERIES REMOTE CONTROL ENTRY SYSTEM CMD-9000 COMMANDER SERIES REMOTE CONTROL ENTRY SYSTEM INTRODUCTION Thank you for purchasing the CMD-9000 Commander from Dakota Digital. This, along with many other products that Dakota Digital has to offer,

More information

ACS-30-EU-EMDR-10-MOD

ACS-30-EU-EMDR-10-MOD Multi-application heat tracing Control and Monitoring in commercial and residential buildings Roof & Gutter de-icing sensor module Technical Information Approvals Module IP rating Ambient operating temperature

More information

CAUTION! THE 7I29 USES VOLTAGE AND POWER LEVELS THAT REPRESENT A HAZARD TO LIFE AND LIMB.

CAUTION! THE 7I29 USES VOLTAGE AND POWER LEVELS THAT REPRESENT A HAZARD TO LIFE AND LIMB. 7I29 MANUAL Rev 1.5 CAUTION! THE 7I29 USES VOLTAGE AND POWER LEVELS THAT REPRESENT A HAZARD TO LIFE AND LIMB. THE 7I29 IS INTENDED FOR USE BY OEMS THAT WILL INTEGRATE IT INTO A SYSTEM WITH INTERLOCKS AND

More information

8 Channel Status Input Panel model SIP-8

8 Channel Status Input Panel model SIP-8 Description The Sine Systems model SIP-8 Status Input Panel is to be used with the RFC-1/B Remote Facilities Controller. It consists of a long PC board mounted on a 1.75 inch (1U) rack panel. The SIP-8

More information

EPM3. Phase Sequence and Motor Rotation Tester. Users Manual

EPM3. Phase Sequence and Motor Rotation Tester. Users Manual EPM3 Phase Sequence and Motor Rotation Tester Users Manual 1 L1 L2 L3 2 3 A B C CAT 600V 3-PHASE TESTER 5 TEST M1 M2 BATT M3 EPM3 MOTOR ROTATION TESTER EPM3 MOTOR ROTATION DETERMINED WHILE FACING MOTOR

More information

TAC2C & TAC2D TAC1 RETROFIT KIT FOR CROWN JEWEL & DOORKING 1812 SYSTEMS

TAC2C & TAC2D TAC1 RETROFIT KIT FOR CROWN JEWEL & DOORKING 1812 SYSTEMS The Chamberlain Group 845 Larch Ave. Elmhurst, IL 60126-1196 www.liftmaster.com TAC2C & TAC2D TAC1 RETROFIT KIT FOR CROWN JEWEL & DOORKING 1812 SYSTEMS 1 2 3 4 5 6 7 8 9 * 0 # 1 2 3 4 5 6 7 8 9 * 0 # Programming

More information

HM-W536 Install Guide

HM-W536 Install Guide HM-W536 Install Guide 9/13/2013 IMPORTANT SAFETY INSTRUCTIONS Warning - When using electrical devices, basic safety precautions should be followed to reduce the risk of fire, electrical shock or injury.

More information

for DNE-K07 Reference and Installation Manual

for DNE-K07 Reference and Installation Manual for DNE-K07 Reference and Installation Manual TABLE OF CONTENTS INTRODUCTION...2 Specifications... 3 Navigation... 3 INSTALLATION...4 Viewing Angle... 4 Keypad Cover Clearance... 4 Mounting the Metal

More information

LOSB9595 1/36 th Brushless ESC and 10250Kv Motor Combination

LOSB9595 1/36 th Brushless ESC and 10250Kv Motor Combination LOSB9595 1/36 th Brushless ESC and 10250Kv Motor Combination Thank you for purchasing this Losi High Performance Brushless System! This technically advanced system will offer maintenance free operation,

More information

DORMA MODEL PS-406BB POWER SUPPLY INSTALLATION INSTRUCTIONS

DORMA MODEL PS-406BB POWER SUPPLY INSTALLATION INSTRUCTIONS Features: INSTALLATION Install in accordance with NFPA 70. DORMA MODEL PS-406BB POWER SUPPLY INSTALLATION INSTRUCTIONS Up to 1.95 Amps Load Capacity Class 2 Rated Outputs Overload, Over Voltage, and Short

More information

Crow Limited Warranty. Print Version 017

Crow Limited Warranty. Print Version 017 Crow Limited Warranty (Crow) warrants this product to be free from defects in materials and workmanship under normal use and service for a period of one year from the last day of the week and year whose

More information

Electric Panel Pump Control System. Operation, Maintenance and Installation Manual

Electric Panel Pump Control System. Operation, Maintenance and Installation Manual Manual No. 5EP-OM1-1 Electric Panel Pump Control System Operation, Maintenance and Installation Manual INTRODUCTION... 1 RECEIVING AND STORAGE... 1 DESCRIPTION OF OPERATION... 1 INSTALLATION... 2 SEQUENCE

More information

Safety Manual BT50(T) Safety relay / Expansion relay

Safety Manual BT50(T) Safety relay / Expansion relay Safety Manual BT50(T) Safety relay / Expansion relay ABB Jokab Safety Varlabergsvägen 11, SE-434 39, Sweden www.abb.com/jokabsafety Read and understand this document Please read and understand this document

More information