Lippincott Williams & Wilkins
|
|
|
- Ashley Carson
- 10 years ago
- Views:
Transcription
1 ORIGINAL ARTICLE Early Results of the Less Invasive Stabilization System for Mechanically Unstable Fractures of the Distal Femur (AO/OTA Types A2, A3, C2, and C3) Mark Weight, MD and Cory Collinge, MD Objectives: Historically, mechanically unstable fractures of the distal femur have been difficult to treat. Problems such as varus collapse, malunion, and nonunion frequently resulted before fixed-angle plates and indirect reduction techniques were popularized. More recently, the Less Invasive Stabilization System, or LISS (Synthes, Paoli, PA), has been designed to combine these 2 approaches with the intended goals of achieving adequate stable fixation and early healing. Early clinical results for the femoral Less Invasive Stabilization System have been promising. The purpose of this study is to evaluate the clinical results of patients with high energy, mechanically unstable fractures of the distal femur treated with the Less Invasive Stabilization System. Design: Retrospective analysis of a treatment protocol, consecutive patient series. Setting: Busy level II trauma center. Patients /Participants: Twenty-six patients with 27 high-energy AO/OTA types A2, A3, C2, and C3 fractures of the distal femur. Intervention: Treatment with indirect fracture reduction and internal distal femoral fixation using the Less Invasive Stabilization System. Main Outcome Measurements: Clinical and radiographic assessment. Results: Twenty-one patients with 22 fractures were available for evaluation at an average 19 months postinjury (range months). The mechanism of injury included 12 motor vehicle collisions, 4 high falls, 5 motorcycle crashes, and 1 bicyclist struck by a car. Twenty patients had associated injuries. Six fractures were open. All fractures were comminuted; according to the AO/OTA fracture classification Accepted for publication April 28, From the Harris Methodist Hospital-Fort Worth and Fort Worth Affiliated Hospitals/John Peter Smith Orthopaedic Surgery Residency, Fort Worth, TX. The implants discussed in this manuscript have been 510K approved by the US Federal Drug Administration. No direct financial or other support has been provided to the authors from the makers of the implants discussed in this manuscript. Reprints: Cory Collinge, MD, 800 5th Street, Suite 500, Fort Worth, TX ( [email protected]). Copyright 2004 by Lippincott Williams & Wilkins there were 4 A2, 3 A3, 12 C2, and 3 C3 fractures. All fractures healed without secondary surgeries at a mean of 13 weeks (range 7 16 weeks). There were no cases of failed fixation, implant breakage, or infection. Average joint line orientation relative to the femoral shaft axis (valgus) measured 99 on postoperative radiographs and 99 on final radiographs. A comparison of postoperative to healed final radiographs for each femur demonstrated no case with greater than a 3 difference in either varus or valgus. Complications included 1 malunion where the fracture was fixed in 8 of valgus and 2 cases of external rotation between 10 and 15. Painful hardware occurred in 4 patients, of which 3 underwent implant removal. The average knee range of motion was 5 to 114. Conclusions: The Less Invasive Stabilization System allows for stable fixation and facilitates early healing in mechanically unstable high-energy fractures of the distal femur. There were no patients with fixation failure, varus collapse, or nonunion in this at-risk population. This treatment safely allows for immediate postoperative initiation of joint mobility and the progression of weight bearing with early radiographic signs of healing. Key Words: minimally invasive plating, biologic plating, fracture fixation, femur, supracondylar femur (J Orthop Trauma 2004;18: ) Historically, the treatment of distal femur fractures has not produced a high percentage of excellent clinical results. Thin cortices, osteoporosis, a wide intramedullary canal, and fracture comminution have made stable fixation of these injuries difficult to achieve and maintain with traditional operative methods. In the 1970s and early 1980s, these injuries were approached with open reduction and internal fixation using established methods and standard implants. After early attempts at surgical treatment, however, relatively high complication rates were found that adversely affected clinical results. 1 9 Problems including infection, nonunion or delayed union, malunion, the need for bone graft, and stiffness due to delayed mobility were common. 2,7 12 Additionally, use of traditional methods to treat mechanically unstable distal femoral fractures resulted in problems with healing and failure of fixation resulting in varus collapse. 1,5,11 17 Subsequently, alternative meth- J Orthop Trauma Volume 18, Number 8, September
2 Weight and Collinge J Orthop Trauma Volume 18, Number 8, September 2004 ods for comminuted or unstable fractures of the distal femur were proposed, including double plating, 13,18,19 use of plates for endosteal substitution, 1,20 22 and anatomically contoured plates. In the 1980s, advances in fracture care were applied to these difficult injuries and clinical results improved. First, indirect reduction and improved maintenance of the fracture biology was popularized by Mast et al and others. 1,23,24 Second, improvements in implant design occurred, leading to fixedangle plates such as the 95 angle blade plate and dynamic condylar screw. These fixed-angle implants impart a measure of stability to plate fixation in this area not previously available: in particular, they resist relative shortening of the medial side that may result in varus deformity. When these 2 treatments were employed together, dramatically improved rates of bone healing and fewer complications of treatment were found compared with historical controls. 2 Recently, locked plating systems have been developed, where screws are inserted that attach to the plate forming a multiple fixed-angle construct. Some of these systems are designed to apply the implants in a minimally invasive fashion that may diminish problems with fracture healing and infection ,25 28 Additionally, the Less Invasive Stabilization System, or LISS (Synthes USA, Paoli, PA), functions as an internal fixator, as the implant is designed not to compress the periosteum, thus potentially allowing maintenance of the vascularity to the injured bone (Fig. 1). Early clinical results for the distal femoral LISS have been promising. 19,29,30 To date, however, no study has specifically looked at the results of high-energy, mechanically unstable fractures of the distal femur (AO/OTA types A2, A3, C2, and C3) 31 treated with LISS. The purpose of this study is to evaluate early clinical and radiographic results of patients treated for these high-energy, mechanically unstable fractures of the distal femur (AO/OTA A2, A3, C2, and C3) 31 using the distal femoral LISS. METHODS Twenty-six patients identified from our trauma registry with 27 mechanically unstable distal femur fractures (AO/OTA 33-A2, A3, C2, and C3) 31 that were treated with LISS between August 1999 and October All fractures were treated by a single fellowship-trained orthopaedic trauma surgeon at a busy level II trauma facility. Treatment of patients with these injuries included a protocol of early fracture fixation using either LISS definitively or spanning of the fracture and knee joint with a temporizing external fixator. Open fractures, fractures with articular comminution, and polytraumatized patients were treated in a staged fashion. Definitive treatment included open reduction of any intra-articular fractures, indirect reduction of metaphyseal and metadiaphyseal fractures, and minimally invasive plate application and fixation. Operative treatment of the patients included in this report is as follows. Patients were positioned supine on a radiolucent operating table. A wide surgical prep of the entire lower extremity was performed, and prophylactic antibiotics were administered. If an external fixator was in place, it was carefully cleansed with iodine soap and paint and handled as little as possible throughout the case. Alcohol moistened sponges were placed around the pin sites and held in place with elastic gauze. A 5 to 10 cm skin incision was made along the lateral aspect of the distal femur and the iliotibial band fibers were incised in line with the skin. Displaced articular injuries were addressed first with reduction and application of 1 or 2 small fragment lag screws placed anterior to the expected site of plate placement. The surgical tactic was altered for comminuted articular fractures to include a lateral parapatellar approach to the joint to allow for improved access for articular reconstruction. Indirect reduction of the metaphyseal or metadiaphyseal fractures was achieved by a combination of methods. The external fixator (Stryker-Howmedica-Osteonics, Mahwah, NJ), FIGURE 1. Case example of a typical distal femur fracture treated in this series. A, Injury radiographs demonstrating high-energy distal femur fracture. B, Postoperative radiographs after minimally invasive treatment with LISS. C, Radiographs of healed fracture at 5.5 months Lippincott Williams & Wilkins
3 J Orthop Trauma Volume 18, Number 8, September 2004 LISS for Mechanically Unstable Fractures of the Distal Femur if present, or a femoral distractor (Synthes USA) was used to gain length and was universally helpful in reduction. A wellplaced knee roll was used in all cases to aid in obtaining and maintaining reduction in flexion extension. Additional tools used for indirect reduction included the whirlybird device from the LISS set, Kirschner wire joysticks, or gentle manipulation of the condylar fragment using a large periarticular clamp (DePuy-Ace, Warsaw, IN). Using the radiolucent arm as a handle, the plate was inserted above the periosteum of the lateral femur in a submuscular tunnel beneath the vastus lateralis. The plate is designed to fit the anatomy of the distal femur and was applied such that the plate was nestled up next to the metaphyseal flare and lateral condyle of the distal femur by sliding it proximally and distally. The plate was centered on bone both proximally and distally and oriented flush with the lateral femoral condyle. A large periarticular clamp was used distally to gently hold the bone to the plate, which typically aided in the sagittal plane fracture reduction. All of these fractures had some level of comminution, and, in many cases, approximation of the normal anatomy was necessary. The opposite uninjured femur was useful as a template in many of these cases, as bony landmarks on the injured side were obscured by fracture. Great effort was then expended toward critically assessing the fracture alignment in varus-valgus, flexion extension, as well as rotation, prior to application of definitive fixation, a basic principle when using indirect reduction methods. Quality imaging was used, including an anterior-posterior (AP) view to assess varus-valgus, and a true lateral view to assess plate placement and flexion extension. Restoration of limb alignment in rotation was assessed clinically as compared to the contralateral side on preoperative examination. The successful use of the LISS system for the treatment of complicated fractures is technique dependent, and a learning curve exists. Once the LISS plate was inserted, a mini-open approach was performed at the proximal end of the plate to ensure that the plate was centered on the lateral side of the femur bone. A locking bolt in the most proximal screw hole was then inserted into the most proximal screw hole; this added stability to the aiming arm by rectangularizing the construct. Any gross adjustment of fracture reduction was done before provisional fixation was applied, using K-wires through the cannulated stabilization bolts. The whirlybird push-pull device was applied to bring the shaft of the femur toward the plate, fine tune the varus-valgus alignment, and augment stability of the provisional construct. At this time, great effort was again made to carefully scrutinize the fracture reduction in all planes before application of definitive fixation. Self-drilling locking screws (5 mm) were first placed for fixation into the condylar segment, and then into the shaft portion after drilling and measuring with K-wires. Considerable effort was made to apply K-wires and screws parallel to the joint surface as assessed on the AP imaging as a guide for restoring alignment. All screws were inserted in a unicortical fashion. They were placed using irrigation to cool the selfdrilling screws in an effort to prevent potential problems with bony necrosis and loss of fixation. Once adequate fixation was achieved, the guide system was removed and the wounds irrigated, dried, and closed. External fixators were only removed after all plating wounds were closed and sterilely dressed. Postoperatively, knee motion was initiated in patients on day 1 or 2 using physical therapy while they were awake. For those patients remaining intubated or in the intensive care unit, a continuous passive motion machine (CPM) in patients was used. Progressive weight bearing was encouraged once there was radiographic evidence of callus formation. Clinical and radiographic examinations were performed until the fracture was healed, and patients more than 12 months postinjury were called back in and examined. Records and radiographs were reviewed for demographics, fracture type, postoperative alignment, time to fracture healing (3 cortices bridged), and complications. Final clinical and radiographic evaluation was performed for knee range of motion, limb rotation, fracture healing, and final radiographic alignment. Final radiographic alignment was assessed using standing bilateral AP and lateral views of the distal femurs on long cassettes. Alignment in varus-valgus was assessed on long AP views with the patient standing, using the intramedullary line of the femur relative to that of the distal femoral articular surface. Flexion extension was evaluated on the lateral view by comparing the lines of the posterior (or anterior) cortical bone. Limb rotation was assessed with the patient prone and the knee flexed; this was compared to the contralateral side. RESULTS Of 26 patients, 2 died and 3 were lost to follow-up, leaving 21 patients with 22 fractures available for study. Of these 21 patients, the average age was 44 years (17 71 years) and follow-up averaged 18 months (range months). Fourteen men and 7 women were available for inclusion. There was a high-energy mechanism of injury in all cases, including 12 motor vehicle collisions, 5 motorcycle crashes, 2 falls from a height greater than 10 feet, a parachuting accident (bilateral), and 1 bicyclist struck by a car. According to the AO/OTA fracture classification, there were 4 A2, 3 A3, 12 C2, and 3 C3 fractures (Fig. 2). 31 Only 1 patient had significant bone loss. Fifteen of 22 fractures extended proximally into the femoral diaphysis. Six fractures were open and were classified as 1 grade I, 1 grade II, and 4 grade III open fractures according to the system of Gustilo and Anderson. 32 There were 2 periprosthetic fractures, one in an active 71-year-old man with a total hip arthroplasty and the other in an active 71-year-old woman above a knee arthroplasty. Neither had profound signs of osteopenia radiographically nor were they being treated for os Lippincott Williams & Wilkins 505
4 Weight and Collinge J Orthop Trauma Volume 18, Number 8, September 2004 teoporosis. Fourteen of 22 fractures were initially treated with a knee spanning external fixator, and definitive surgery was delayed until the patient and/or soft tissues had recovered enough to safely undergo surgery (mean 5 days, range 2 18 days). All fractures healed without secondary surgery. The mean time to healing was 13 weeks (range 7 16 weeks). There were no cases of failed fixation, nonunion, or infection, and no bone grafts were required. The mean time to full weight bearing was 11.5 weeks (range 8 15 weeks). Average joint line orientation relative to the femoral shaft axis measured 99 (valgus) on postoperative radiographs and 99 on final radiographs. 9 No patient measured a difference of more than 3 from postoperation to final radiographs. The average anatomic axis of the contralateral side measured 97. Only 1 of 22 fractures had greater than a 5 alteration of alignment in varus-valgus or flexion extension, a case found to be fixed in 8 of valgus relative to the other side. Two patients were found to have external rotation deformity of 10 to 15 relative to the contralateral side, but one of these had trauma to the contralateral femur. None had greater than a 15 difference in limb rotation from side to side. Four patients had symptomatic instrumentation at the lateral distal femur. Three had complete relief after implant removal, and 1 has surgery scheduled. Two patients underwent late knee ligament reconstruction, one for a symptomatic anterior cruciate deficiency and the other for an unstable posterolateral corner injury. No other secondary surgeries were performed. The average range of motion was 5 to 114 (extension range 2 22, flexion range ). One patient with a C3 fracture pattern and associated severe ligamentous knee injury developed Brooker grade IV heterotopic ossification and marked knee stiffness. Excluding this patient, the average range of motion was 3 to 119. Extra-articular fractures or AO/OTA type A fractures had a mean arc of motion from 2 to 130, whereas intra-articular injuries or AO/OTA type C had an arc of motion of 7 to 102 (P < 0.01). The average knee range of motion for patients with open fractures was 3 to 117. FIGURE 2. AO/OTA classification demonstrating mechanically unstable fracture types treated in this series. DISCUSSION Minimally invasive plating techniques have been developed as a method of fracture fixation where additional soft tissue trauma is minimized and the fracture biology is left intact. The goals of these techniques are to restore the important anatomy, provide stable fixation, and to promote early fracture healing. This method of treatment has been applied to fractures of the distal femur, 19,21,22,29,30 as well as other complex lower extremity injuries from the hip to the pilon. 1,21,22,25,26,28 The use of fixed-angle implants has also shown benefits in the treatment of complex lower extremity injuries, including the distal femur. 10,20,21,24 Recently, LISS was developed with the rationale of combining the biologic advantages of a minimally invasive insertion technique with the mechanical advantages of a multiple fixed-angle device. Previous studies have demonstrated successful early results and relatively low complication rates using this treatment method for fractures of the distal femur. 19,29,30 The goal of this report was to specifically evaluate the results of LISS in mechanically unstable high-energy fractures of the distal femur where the stability of the fixation construct and preservation of fracture biology may be critical. All 22 high-energy, mechanically unstable fractures of the distal femur treated in this study group healed after the index procedure at an average of 13 weeks. There were no cases of fixation failure or implant breakage, and no fracture required bone grafting. Little information is available as to the results of treatments for high-energy injuries of the distal femur or those with mechanically unstable fractures that may be especially prone to healing or alignment problems and diminished clinical results. Two distinct patterns of distal femur injury have been recognized, 2,12,15,19,20,24,29 those in young patients resulting from high-energy trauma and those in elderly osteoporotic patients suffering low-energy injuries. To date, previous reports have made no clinical distinction between these 2 distinct types of injury, and results have been grouped together for analysis. 2 8,14 16,18 21,24,27,29,30 Historically, treatment failures have been relatively common, and complication rates have been high for these injuries. 2 7 Early attempts at open anatomic reduction and rigid internal fixation with traditional plates had significant problems, with delayed or nonunion occurring in 29% to 38% of fractures 5,33 and infection rates of 7% to 20%. 3,27,34 These Lippincott Williams & Wilkins
5 J Orthop Trauma Volume 18, Number 8, September 2004 LISS for Mechanically Unstable Fractures of the Distal Femur problems likely reflect the effects of further trauma on the surrounding soft tissues during the wide dissection required for the technique. Dramatically improved results have been reported in similar injuries using more biologic approaches and improved implants. 20,23,24 Reports by Bolhofner et al 20 and Ostrum and Geel 24 in treating distal femur fractures with techniques of indirect fracture reduction and internal fixation using 95 fixed-angle devices revealed markedly improved results compared with previous methods. They found early union in 93% to 100% of fractures and infections in only 0% to 2% of cases. The authors do, however, acknowledge certain limitations of their surgical technique, including the demanding nature of correct implant insertion and that it may not be suitable for all injuries. Early reports on distal femur fractures treated with similar principles using LISS have shown promising results as well. Schutz et al described their early results from multiple European centers 30 ; they found early healing in 37 of 40 patients (93%) treated for fractures with the distal femoral LISS. Kregor et al reported early union in 58 of 61 patients (95%) with distal femur fractures treated similarly with LISS. 29 The authors attribute successful early healing to vigilant maintenance of the fracture biology and strict adherence to the fixation principles of LISS. We have found that using indirect fracture reduction and fixation with LISS provides ample fixation to maintain fracture alignment in these high-energy and mechanically unstable fractures. In this series, the authors found no problems with fixation failure, varus collapse, or other changes in alignment postoperatively for injuries at risk, and radiographic alignment remained unchanged from operative fixation to final healed radiographs. Although earlier series demonstrated excellent fixation in the relatively osteopenic distal or condylar segment, 19,29,30 Schandelmaier et al found 4 patients whose fixation failed due to proximal screw pullout in their series of patients with a combination of low-energy and high-energy injuries. 19 Our results demonstrated no problems with either proximal or distal fixation. This may be attributed to the dissemination of information regarding the learning curve for this system and technique. Proximal failure due to eccentric placement of the plate on the lateral femur may result in inadequate purchase of the unicortical screws; this problem has been well recognized and may be avoided relatively easily. 19,29,30 Three of 22 fractures treated resulted in malunion found in this series. One patient experienced an 8 valgus deformity, and 2 others were found with mild deformities in external rotation. All were operatively fixed in these positions early in this series. Persistent deformity has been noted as the most common risk in minimally invasive fracture surgery, with rates as high as 32% or 44%. 19,21,22,28 The question no longer appears to be will the fracture heal or will it heal straight, but will we fix it straight? Most of the preliminary reports where malunion rates were extremely high described techniques that were still evolving at the time. 21,22,25,26 Although the risk for malunion is real, improved results should be expected if careful vigilance toward achieving alignment intraoperatively is observed. Limitations of this study include all of the shortcomings inherent to its retrospective nature. Also, there is no alternative treatment or control group included in this study with which to compare these results. There are 2 main strengths of this study. First, it is a consecutive series by a single surgeon who had the opportunity to consider and benefit from the learning curve of others. Strict adherence to the mechanical, biologic, and technical principles of LISS were upheld. Thus, these mostly positive clinical results should be reproducible by other orthopaedic surgeons. Second, the data analyzed only pertain to a limited type of patient, which are those who have experienced high-energy trauma resulting in comminuted or mechanically unstable fractures. These are patients that may reap the most benefit from these treatment methods, that is, a minimally invasive approach and use of fixed-angle implants. CONCLUSIONS A multiple fixed-angle and minimally invasive plating system such as LISS provides adequate stable fixation and facilitates early healing in mechanically unstable, high-energy fractures of the distal femur. There were no nonunions or patients who required bone grafting in this series of 22 similar fractures. There were no problems with fixation failure, varus collapse, or other postoperative changes in alignment in this at risk population. Radiographic alignment remained unchanged from operative fixation to final healed radiographs. It appears that LISS achieves the goals of stable fixation and early healing in these mechanically unstable injuries. It must be remembered that careful intraoperative attention should be given to restoring alignment in all planes. REFERENCES 1. Mast J, Jakob R, Ganz R. Planning and Reduction Technique in Fracture Surgery. New York, NY: Springer; Neer CS, Grantham SA, Shelton ML. Supracondylar fracture of the adult femur. A study of one hundred and ten cases. J Bone Joint Surg. 1967; 49A: Olerud S. Operative treatment of supracondylar fractures of the femur. Technique and results in fifteen cases. J Bone Joint Surg. 1972;54A: Pritchett JW. Supracondylar fractures of the femur. Clin Orthop. 1984: Schatzker J, Horne G, Waddell J. The Toronto experience with the supracondylar fracture of the femur, Injury. 1975;6: Slatis P, Ryoppy S, Huttinen V. AO osteosynthesis of fractures of the distal third of the femur. Acta Orthop Scand. 1971;42: Stewart MJ, Sisk TD, Wallace SL. Fractures of the distal end of the femur. J Bone Joint Surg. 1966;48A: White EH, Russin LA. Supracondylar fractures of femur treated by internal fixation with immediate knee motion. Am J Surg. 1956;22: Zehntner MK, Marchesi DG, Burch H, et al. Alignment of supracondylar fractures of the femur after internal fixation by AO/ASIF technique. J Orthop Trauma. 1992;6: Altenberg AR, Shorkey RL. Blade plate fixation in nonunion and in com Lippincott Williams & Wilkins 507
6 Weight and Collinge J Orthop Trauma Volume 18, Number 8, September 2004 plicated fractures of the supracondylar region of the femur. J Bone Joint Surg. 1949;31A: Miclau T, Martin RE. The evolution of modern plate osteosynthesis. Injury. 1997;28(suppl 1):A3 A Moore T, Watson T, Green S, et al. Complications of surgically treated supracondylar fractures of the femur. J Trauma. 1987;27: Sanders R, Regazzoni P, Reudi T. Treatment of supracondylar intraarticular fractures of the femur using the dynamic condylar screw. J Orthop Trauma. 1989;3: Sanders R, Swiontkowski M, Rosen H, et al. Complex fractures and malunions of the distal femur: results of treatment with double plates. J Bone Joint Surg Am. 1991;73A: Schatzker J, Lambert DC. Supracondylar fractures of the femur. Clin Orthop. 1979;10: Siliski JM, Mahring M, Hofer HP. Supracondylar-intercondylar fractures of the femur: treatment by internal fixation. J Bone Joint Surg Am. 1989; 71A: Zickel R. Nonunions of fractures of the proximal and distal thirds of the shaft of the femur. Instr Course Lect. 1988;37: Jazrawi LM, Kummer FJ, Simon JA, et al. New technique for treatment of unstable distal femur fractures by locked double-plating: case report and biomechanical evaluation. J Trauma. 2000;48: Schandelmaier P, Partenheimer A, Koenemann B, et al. Distal femoral fractures and LISS stabilization. Injury. 2001;32(suppl 3): Bolhofner BR, Carmen B, Clifford P. The results of open reduction and internal fixation of distal femur fractures using a biologic (indirect) reduction technique. J Orthop Trauma. 1996;10: Krettek C, Schandelmaier P, Miclau T, et al. Minimally invasive percutaneous plate osteosynthesis (MIPPO) using the DCS in proximal and distal femoral fractures. Injury. 1997;28(suppl 1): Krettek C, Schandelmaier P, Miclau T, et al. Transarticular joint reconstruction and indirect plate osteosynthesis for complex distal supracondylar femoral fractures. Injury. 1997;28(suppl 1): Henry SL. Supracondylar femur fractures treated percutaneously. Clin Orthop. 1998;350: Ostrum RF, Geel C. Indirect reduction and internal fixation of supracondylar femur fractures without bone graft. J Orthop Trauma. 1995;9: Collinge CA, Sanders RW. Percutaneous plating in the lower extremity. J Am Acad Orthop Surg. 2000;8: Collinge C, Sanders R, DiPasquale T. Treatment of complex tibial periarticular fractures using percutaneous techniques. Clin Orthop. 2000;375: Farouk O, Krettek C, Miclau T, et al. The minimal invasive plate osteosynthesis: is percutaneous plating biologically superior to the traditional technique? J Orthop Trauma. 1999;13: Helfet D, Shonnard P, Levine D, et al. Minimally invasive plate osteosynthesis of distal fractures of the tibia. Injury. 1997;28(suppl 1): Kregor PJ, Stannard J, Zlowodzki M, et al. Distal femora fracture fixation utilizing the Less Invasive Stabilization System (L.I.S.S.): the technique and early results. Injury. 2001;32(suppl 3): Schutz M, Muller M, Krettek C, et al. Minimally invasive fracture stabilization of distal femoral fractures with the LISS: a prospective multicenter study. Result of a clinical study with special emphasis on difficult cases. Injury. 2001;32(suppl 3): Orthopaedic Trauma Association Committee for Coding and Classification. Fracture and dislocation compendium. J Orthop Trauma. 1996;10 (suppl 1): Gustilo RB, Anderson JT. Prevention of infection in the treatment of one thousand and twenty-five open fractures of long bones: retrospective and prospective analyses. J Bone Joint Surg. 1976;58A: Giles JB, DeLee JC, Heckman JD, et al. Supracondylar-intercondylar fractures of the femur treated with a supracondylar plate and lag screw. J Bone Joint Surg. 1982;64A: Mize RD, Bucholz RW, Grogan DP. Surgical treatment of displaced, comminuted fractures of the distal end of the femur. J Bone Joint Surg. 1982;64: Lippincott Williams & Wilkins
Zimmer Periarticular Proximal Tibial Locking Plate
Zimmer Periarticular Proximal Tibial Locking Plate Surgical Technique The Science of the Landscape Zimmer Periarticular Proximal Tibial Locking Plate 1 Table of Contents Introduction 2 Locking Screw Technology
Zimmer Small Fragment Universal Locking System. Surgical Technique
Zimmer Small Fragment Universal Locking System Surgical Technique Zimmer Small Fragment Universal Locking System 1 Zimmer Small Fragment Universal Locking System Surgical Technique Table of Contents Introduction
Technique Guide. Large Fragment LCP Instrument and Implant Set. Part of the Synthes locking compression plate (LCP) system.
Technique Guide Large Fragment LCP Instrument and Implant Set. Part of the Synthes locking compression plate (LCP) system. Table of Contents Introduction Large Fragment LCP Instrument and Implant Set
PERIPROSTHETIC IMPLANTS
PERIPROSTHETIC IMPLANTS PRODUCT OVERVIEW CLINICAL SOLUTIONS Periprosthetic fractures present unique challenges, such as how to gain fixation when the medullary canal is occupied. Special techniques and
Technique Guide. DHS/DCS Dynamic Hip and Condylar Screw System. Designed to provide stable internal fixation.
Technique Guide DHS/DCS Dynamic Hip and Condylar Screw System. Designed to provide stable internal fixation. Table of Contents Introduction Dynamic Hip Screw (DHS) 2 Dynamic Condylar Screw (DCS) 3 Indications
OptiLock Periarticular Plating System For Proximal Tibial Fractures. Pre-Launch Surgical Technique
OptiLock Periarticular Plating System For Proximal Tibial Fractures Pre-Launch Surgical Technique Contents Introduction... Page 1 Indications & Fracture Classifications... Page 4 Design Features... Page
NCB Distal Femur System. Surgical Technique
NCB Distal Femur System Surgical Technique NCB Distal Femur System Surgical Technique 3 Surgical Technique NCB Distal Femur System Table of Contents Introduction 4 Indications 8 Preoperative Planning
QUESTION I HAVE BEEN ASKED TO REHAB GRADE II AND III MCL INJURIES DIFFERENTLY BY DIFFERENT SURGEONS IN THE FIRST 6WEEKS FOLLOWING INJURY.
QUESTION I HAVE BEEN ASKED TO REHAB GRADE II AND III MCL INJURIES DIFFERENTLY BY DIFFERENT SURGEONS IN THE FIRST 6WEEKS FOLLOWING INJURY. SOME ARE HINGE BRACED 0-90 DEGREES AND ASKED TO REHAB INCLUDING
Technique Guide. 3.5 mm and 4.5 mm Curved Locking Compression Plates (LCP). For minimally invasive osteosynthesis.
Technique Guide 3.5 mm and 4.5 mm Curved Locking Compression Plates (LCP). For minimally invasive osteosynthesis. Table of Contents Introduction 3.5 mm and 4.5 mm Curved Locking Compression 2 Plates (LCP)
Zimmer Periarticular Elbow Locking Plate System
Zimmer Periarticular Elbow Locking Plate System Surgical Technique The Right Solutions for Fractures Around the Elbow Disclaimer This document is intended exclusively for physicians and is not intended
Malleolar fractures Anna Ekman, Lena Brauer
Malleolar fractures Anna Ekman, Lena Brauer How to use this handout? The left column is the information as given during the lecture. The column at the right gives you space to make personal notes. Learning
How To Fix A Radial Head Plate
Mayo Clinic CoNGRUENT RADIAL HEAD PLATE Since 1988 Acumed has been designing solutions to the demanding situations facing orthopedic surgeons, hospitals and their patients. Our strategy has been to know
Wrist and Hand. Patient Information Guide to Bone Fracture, Bone Reconstruction and Bone Fusion: Fractures of the Wrist and Hand: Carpal bones
Patient Information Guide to Bone Fracture, Bone Reconstruction and Bone Fusion: Wrist and Hand Fractures of the Wrist and Hand: Fractures of the wrist The wrist joint is made up of the two bones in your
NCB Periprosthetic Femur Plate System. Surgical Technique
NCB Periprosthetic Femur Plate System Surgical Technique NCB Periprosthetic Femur System Surgical Technique 3 Table of Contents Introduction 4 System Features and Benefits 9 Indications and Contraindications
Technique Guide. 2.7 mm/3.5 mm Variable Angle LCP Ankle Trauma System. Part of the Synthes variable angle locking compression plate (VA-LCP) system.
Technique Guide 2.7 mm/3.5 mm Variable Angle LCP Ankle Trauma System. Part of the Synthes variable angle locking compression plate (VA-LCP) system. Table of Contents Introduction 2.7 mm/3.5 mm Variable
Technique Guide. 4.5 mm LCP Proximal Femur Plates. Part of the Synthes Periarticular LCP Plating System.
Technique Guide 4.5 mm LCP Proximal Femur Plates. Part of the Synthes Periarticular LCP Plating System. Table of Contents Introduction 4.5 mm LCP Proximal Femur Plates 2 AO Principles 4 Indications 5 Surgical
Zimmer FuZion Instruments. Surgical Technique (Beta Version)
Zimmer FuZion Surgical Technique (Beta Version) INTRO Surgical Technique Introduction Surgical goals during total knee arthroplasty (TKA) include establishment of normal leg alignment, secure implant fixation,
Spinal Arthrodesis Group Exercises
Spinal Arthrodesis Group Exercises 1. Two surgeons work together to perform an arthrodesis. Dr. Bonet, a general surgeon, makes the anterior incision to gain access to the spine for the arthrodesis procedure.
.org. Distal Radius Fracture (Broken Wrist) Description. Cause
Distal Radius Fracture (Broken Wrist) Page ( 1 ) The radius is the larger of the two bones of the forearm. The end toward the wrist is called the distal end. A fracture of the distal radius occurs when
Technique Guide. VersiTomic. Michael A. Rauh, MD. Anterior Cruciate Ligament Reconstruction
Technique Guide VersiTomic Anterior Cruciate Ligament Reconstruction Michael A. Rauh, MD The opinions expressed are those of Dr. Rauh and are not necessarily those of Stryker VersiTomic Anterior Cruciate
FEMORAL NECK FRACTURE FOLLOWING TOTAL KNEE REPLACEMENT
1 FEMORAL NECK FRACTURE FOLLOWING TOTAL KNEE REPLACEMENT László Sólyom ( ), András Vajda & József Lakatos Orthopaedic Department, Semmelweis University, Medical Faculty, Budapest, Hungary Correspondence:
High-Flex Solutions for the MIS Era. Zimmer Unicompartmental High Flex Knee System
High-Flex Solutions for the MIS Era Zimmer Unicompartmental High Flex Knee System Zimmer Unicompartmental High Flex Knee Built On Success In today s health care environment, meeting patient demands means
Anatomic Percutaneous Ankle Reconstruction of Lateral Ligaments (A Percutaneous Anti ROLL)
Anatomic Percutaneous Ankle Reconstruction of Lateral Ligaments (A Percutaneous Anti ROLL) Mark Glazebrook James Stone Masato Takao Stephane Guillo Introduction Ankle stabilization is required when a patient
BONE PRESERVATION STEM
TRI-LOCK BONE PRESERVATION STEM Featuring GRIPTION Technology SURGICAL TECHNIQUE IMPLANT GEOMETRY Extending the TRI-LOCK Stem heritage The original TRI-LOCK Stem was introduced in 1981. This implant was
Fracture Care Coding September 28, 2011
Fracture Care Coding September 28, 2011 Julie Edens Leu, CPC, CPCO, CPMA, CPC-I 1 Disclaimer Every reasonable effort has been made to ensure that the educational material provided today is accurate and
Imaging of Lisfranc Injury
November 2011 Imaging of Lisfranc Injury Greg Cvetanovich, Harvard Medical School Year IV Agenda Case Presentation Introduction Anatomy Lisfranc Injury Classification Imaging Treatment 2 Case Presentation
.org. Fractures of the Thoracic and Lumbar Spine. Cause. Description
Fractures of the Thoracic and Lumbar Spine Page ( 1 ) Spinal fractures can vary widely in severity. While some fractures are very serious injuries that require emergency treatment, other fractures can
Distal Radius Fractures. Lee W Hash, MD Affinity Orthopedics and Sports Medicine
Distal Radius Fractures Lee W Hash, MD Affinity Orthopedics and Sports Medicine The Problem of Distal Radius Fractures Common injury: >450,000/yr. in USA High potential for functional impairment and frequent
Total Elbow Arthroplasty as Primary Treatment for Distal Humeral Fractures in Elderly Patients*
Copyright 199 by The Journal of Bone and Joint Surgery, Incorporated Total Elbow Arthroplasty as Primary Treatment for Distal Humeral Fractures in Elderly Patients* BY TYSON K. COBB, M.D.f, AND BERNARD
www.ghadialisurgery.com
P R E S E N T S Dr. Mufa T. Ghadiali is skilled in all aspects of General Surgery. His General Surgery Services include: General Surgery Advanced Laparoscopic Surgery Surgical Oncology Gastrointestinal
Scaphoid Non-union. Dr. Mandel Dr. Gyomorey. May 3 rd 2006
Scaphoid Non-union Dr. Mandel Dr. Gyomorey May 3 rd 2006 Introduction Scaphoid fracture incidence: 8-38/100,000 Non-union 5% (0-22%) Adams and Leonard (1928) first described operative treatment of the
How To Use A Phoenix Retrograde Femoral Nail
Phoenix Retrograde Femoral Nail System Featuring CoreLock Technology Surgical Technique Contents Introduction... Page 1 Indications... Page 2 Design Features... Page 3 Surgical Technique... Page 6 Product
Chapter 30. Rotational deformity Buddy taping Reduction of metacarpal fracture
Chapter 30 FINGER FRACTURES AND DISLOCATIONS KEY FIGURES: Rotational deformity Buddy taping Reduction of metacarpal fracture Because we use our hands for so many things, finger fractures and dislocations
Calcaneus (Heel Bone) Fractures
Copyright 2010 American Academy of Orthopaedic Surgeons Calcaneus (Heel Bone) Fractures Fractures of the heel bone, or calcaneus, can be disabling injuries. They most often occur during high-energy collisions
THE MEASUREMENT AND ANALYSIS OF AXIAL DEFORMITY AT THE KNEE
THE MEASUREMENT AND ANALYSIS OF AXIAL DEFORMITY AT THE KNEE Kenneth A. Krackow, M.D. Clinical Director, Department of Orthopaedic Surgery Kaleida Health System Buffalo General Hospital Professor and Full
Structure and Function of the Hip
Structure and Function of the Hip Objectives Identify the bones and bony landmarks of the hip and pelvis Identify and describe the supporting structures of the hip joint Describe the kinematics of the
LISS PLT. The less invasive stabilization system for proximal tibia fractures.
LISS PLT. The less invasive stabilization system for proximal tibia fractures. Surgical Technique This publication is not intended for distribution in the USA. Instruments and implants approved by the
Anterior Lumbar Interbody Fusion (ALIF). Instrument set supports placement of ALIF spacers using anterior or anterolateral approach.
Anterior Lumbar Interbody Fusion (ALIF). Instrument set supports placement of ALIF spacers using anterior or anterolateral approach. Technique Guide Instruments and implants approved by the AO Foundation
Posterior Referencing. Surgical Technique
Posterior Referencing Surgical Technique Posterior Referencing Surgical Technique INTRO Introduction Instrumentation Successful total knee arthroplasty depends in part on re-establishment of normal lower
V-TEK IVP System 2.7 System 4.0
V-TEK IVP System Ankle 2.7 Fix System 4.0 Surgical Technique Surgical Technique Titanium osteosynthesis system for tibio-talar and tibio-talo-calcaneal fusion SECTION 1 Ankle Fix System 4.0 Titanium osteosynthesis
INJURIES OF THE HAND AND WRIST By Derya Dincer, M.D.
05/05/2007 INJURIES OF THE HAND AND WRIST By Derya Dincer, M.D. Hand injuries, especially the fractures of metacarpals and phalanges, are the most common fractures in the skeletal system. Hand injuries
Surgical technique. End Cap for TEN. For axial stabilization and simultaneous protection of soft tissue.
Surgical technique End Cap for TEN. For axial stabilization and simultaneous protection of soft tissue. Table of contents Indications and contraindications 3 Implants 4 Instruments 4 Preoperative planning
LCP Superior Clavicle Plate. The anatomically precontoured fixation system with angular stability for clavicle shaft and lateral clavicle.
LCP Superior Clavicle Plate. The anatomically precontoured fixation system with angular stability for clavicle shaft and lateral clavicle. Surgical Technique This publication is not intended for distribution
Foot and Ankle Technique Guide Proximal Inter-Phalangeal (PIP) Fusion
Surgical Technique Foot and Ankle Technique Guide Proximal Inter-Phalangeal (PIP) Fusion Prepared in consultation with: Phinit Phisitkul, MD Department of Orthopedics and Rehabilitation University of Iowa
.org. Clavicle Fracture (Broken Collarbone) Anatomy. Description. Cause. Symptoms
Clavicle Fracture (Broken Collarbone) Page ( 1 ) A broken collarbone is also known as a clavicle fracture. This is a very common fracture that occurs in people of all ages. Anatomy The collarbone (clavicle)
.org. Ankle Fractures (Broken Ankle) Anatomy
Ankle Fractures (Broken Ankle) Page ( 1 ) A broken ankle is also known as an ankle fracture. This means that one or more of the bones that make up the ankle joint are broken. A fractured ankle can range
Exeter. Surgical Technique. V40 Stem Cement-in-Cement. Orthopaedics
Exeter Orthopaedics V40 Stem Cement-in-Cement Surgical Technique Exeter V40 Stem Cement-in-Cement Surgical Technique Table of Contents Indications and Contraindications...2 Warnings and Precautions...2
Syndesmosis Injuries
Syndesmosis Injuries Dr. Alex Rabinovich Outline Anatomy Injury types and classification Treatment options Nonoperative vs. Operative Indications for operative Operative technique Postoperative management
ASSOCIATED LESIONS COMPLICATIONS OSTEOARTICULAR COMPLICATIONS
Corrective Osteotomy of Distal Radius Malunion---New Horizons I certify that, to the best of my knowledge, no aspect of my current personal or profession situation might reasonably be expected to affect
VERSYS HERITAGE CDH HIP PROSTHESIS. Surgical Technique for CDH Hip Arthroplasty
VERSYS HERITAGE CDH HIP PROSTHESIS Surgical Technique for CDH Hip Arthroplasty SURGICAL TECHNIQUE FOR VERSYS HERITAGE CDH HIP PROSTHESIS CONTENTS ANATOMICAL CONSIDERATIONS....... 2 PREOPERATIVE PLANNING............
Minimally Invasive Hip Replacement through the Direct Lateral Approach
Surgical Technique INNOVATIONS IN MINIMALLY INVASIVE JOINT SURGERY Minimally Invasive Hip Replacement through the Direct Lateral Approach *smith&nephew Introduction Prosthetic replacement of the hip joint
Zimmer Natural Nail System. Cephalomedullary Nail Surgical Technique STANDARD
Zimmer Natural Nail System Cephalomedullary Nail Surgical Technique STANDARD Zimmer Natural Nail System Cephalomedullary Nail Surgical Technique - Standard 1 Zimmer Natural Nail System Cephalomedullary
TransFx External Fixation System Large and Intermediate Surgical Technique
TransFx External Fixation System Large and Intermediate Surgical Technique TransFx External Fixation System Large and Intermediate Surgical Technique 1 Surgical Technique For TransFx External Fixation
Fracture Fixation Devices Compression Hip Screws Cannulated/Bone Screws Bone Plates, Pins, Wires
Fracture Fixation Devices Compression Hip Screws Cannulated/Bone Screws Bone Plates, Pins, Wires IMPORTANT MEDICAL INFORMATION EN SPECIAL NOTE Fracture fixation devices are used only as an aid to healing;
Extra-articular Proximal Tibial Fractures: Nail or Plate?
6 Extra-articular Proximal Tibial Fractures: Nail or Plate? John C. Kurylo, MD Paul Tornetta III, MD Abstract The surgical goals for treating proximal tibial fractures are to restore articular congruity,
TriLock 1.5 Implants for the Phalanges
P R O D U C T IN F O RM AT I O N TriLock 1.5 Implants for the Phalanges APTUS Hand 2 TriLock 1.5 Implants for the Phalanges TriLock 1.5 The Smallest Locking System Small, slender, strong Low profile and
Titanium Wire with Barb and Needle. For canthal tendon procedures.
Titanium Wire with Barb and Needle. For canthal tendon procedures. Technique Guide Instruments and implants approved by the AO Foundation Table of Contents Introduction Titanium Wire with Barb and Needle
Technique Guide. Titanium Trochanteric Fixation Nail System. For intramedullary fixation of proximal femur fractures.
Technique Guide Titanium Trochanteric Fixation Nail System. For intramedullary fixation of proximal femur fractures. Table of Contents Introduction Titanium Trochanteric Fixation Nail System 2 Biomechanical
Zimmer M/L Taper Hip Prosthesis with Kinectiv Technology
Zimmer M/L Taper Hip Prosthesis with Kinectiv Technology Hips designed to fit the unique anatomies of men and women Independent control for a natural fit Simple, practical solutions for optimal restoration
Technique Guide. Orthopaedic Cable System. Cerclage solutions for general surgery.
Technique Guide Orthopaedic Cable System. Cerclage solutions for general surgery. Table of Contents Introduction The Orthopaedic Cable System 2 Indications 4 Contraindications 4 Surgical Technique Cerclage
Versa-Fx II Femoral Fixation System Surgical Techniques
Versa-Fx II Femoral Fixation System Surgical Techniques Versa-Fx II Femoral Fixation System Surgical Techniques 1 Surgical Technique For Fixation Of Intertrochanteric and Supracondylar Fractures of the
Rodding Surgery. 804 W. Diamond Ave., Ste. 210 Gaithersburg, MD 20878 (800) 981-2663 (301) 947-0083
Rodding Surgery 804 W. Diamond Ave., Ste. 210 Gaithersburg, MD 20878 (800) 981-2663 (301) 947-0083 Fax: (301) 947-0456 Internet: www.oif.org Email: [email protected] The Osteogenesis Imperfecta Foundation,
Simplified surgery. Personalized performance.
Simplified surgery. Personalized performance. VISIONAIRE Patient Matched Technology Accuracy Advanced surgical precision, resulting in reproducible outcomes Efficiency Simplifying surgery, reducing costs,
The information contained in this document is intended for healthcare professionals only.
The information contained in this document is intended for healthcare professionals only. Dall-Miles Cabling System Dall-Miles Recon and Trauma Cable System Trochanteric Reattachment Using the Trochanteric
Total Elbow Arthroplasty and Rehabilitation
Total Elbow Arthroplasty and Rehabilitation Surgical Indications and Considerations Anatomical Considerations: There are three bones and four joint articulations that have a high degree of congruence in
Case Report Reconstructive Osteotomy for Ankle Malunion Improves Patient Satisfaction and Function
Case Reports in Orthopedics Volume 2015, Article ID 549109, 5 pages http://dx.doi.org/10.1155/2015/549109 Case Report Reconstructive Osteotomy for Ankle Malunion Improves Patient Satisfaction and Function
Management of common upper limb fractures in Adults and Children. Dr Matthew Sherlock Shoulder and Elbow Orthopaedic Surgeon
Management of common upper limb fractures in Adults and Children Dr Matthew Sherlock Shoulder and Elbow Orthopaedic Surgeon Outline Immobilisation choices Adults Clavicle Fractures Proximal Humeral Fractures
ANTERIOR CERVICAL DISCECTOMY AND FUSION. Basic Anatomical Landmarks: Anterior Cervical Spine
Anterior In the human anatomy, referring to the front surface of the body or position of one structure relative to another Cervical Relating to the neck, in the spine relating to the first seven vertebrae
Aesculap Veterinary Orthopaedics. Targon VET Interlocking Nail
Aesculap Veterinary Orthopaedics Targon VET Interlocking Nail Flexibility Stability Dynamics The Targon VET is based on new, technology which reverses the known principles of interlocking nails. The rotation-stabilising
Radial Head Fracture Repair and Rehabilitation
1 Radial Head Fracture Repair and Rehabilitation Surgical Indications and Considerations Anatomical Considerations: The elbow is a complex joint due to its intricate functional anatomy. The ulna, radius
Adult Forearm Fractures
Adult Forearm Fractures Your forearm is made up of two bones, the radius and ulna. In most cases of adult forearm fractures, both bones are broken. Fractures of the forearm can occur near the wrist at
TRIGEN INTERTAN vs Stryker Gamma3 summary
TRIGEN INTERTAN vs Stryker Gamma3 summary Initial stiffness of INTERTAN construct almost 4% greater than Gamma3 INTERTAN femoral head rotation and varus collapse initially up to 84% lower than Gamma3 After
The goals of surgery in ambulatory children with cerebral
ORIGINAL ARTICLE Changes in Pelvic Rotation After Soft Tissue and Bony Surgery in Ambulatory Children With Cerebral Palsy Robert M. Kay, MD,* Susan Rethlefsen, PT,* Marty Reed, MD, K. Patrick Do, BS,*
Y O U R S U R G E O N S. choice of. implants F O R Y O U R S U R G E R Y
Y O U R S U R G E O N S choice of implants F O R Y O U R S U R G E R Y Y O U R S U R G E O N S choice of implants F O R Y O U R S U R G E R Y Your Surgeon Has Chosen the C 2 a-taper Acetabular System The
PATIENT SPECIFIC PLATES FOR MANDIBLE: CUSTOM MADE PLATES FOR TRAUMA AND RECONSTRUCTION
PATIENT SPECIFIC PLATES FOR MANDIBLE: CUSTOM MADE PLATES FOR TRAUMA AND RECONSTRUCTION Derived from patient CT Data Customizable design features Strength with low profile This publication is not intended
Orthopedic Foot Instruments. Dedicated instruments for reconstructive foot surgery.
Orthopedic Foot Instruments. Dedicated instruments for reconstructive foot surgery. Surgical Technique This publication is not intended for distribution in the USA. Instruments and implants approved by
SALVATION. Fusion Bolts and Beams SURGICAL TECHNIQUE
SALVATION Fusion Bolts and Beams SURGICAL TECHNIQUE Contents Chapter 1 4 Introduction Chapter 2 4 Intended Use Chapter 3 4 Device Description 4 Fusion Beams 5 Fusion Bolts Chapter 4 5 Preoperative Planning
Standard of Care: Tibial Plateau Fracture
Department of Rehabilitation Services Physical Therapy Case Type / Diagnosis: ICD-9: 823.00 - fracture of proximal tibia Tibial plateau fractures can occur as a result of high-energy trauma or in low-energy
Expert LFN. Lateral Femoral Nail.
Expert LFN. Lateral Femoral Nail. Surgical Technique EXPERT Nailing System This publication is not intended for distribution in the USA. Instruments and implants approved by the AO Foundation. Image intensifier
Zimmer Persona Adverse Events Reported to FDA Through 3/27/2015
Event Description: IT IS REPORTED THAT THE PATIENT WAS REVISED DUE TO GROSS ASEPTIC LOOSENING. Manufacturer 1822565-2015- 00224 PERSONA STEMMED CEMENTED TIBIAL COMPONENT 2/23/15 1/21/15 Injury Narrative:
Posttraumatic medial ankle instability
Posttraumatic medial ankle instability Alexej Barg, Markus Knupp, Beat Hintermann Orthopaedic Department University Hospital of Basel, Switzerland Clinic of Orthopaedic Surgery, Kantonsspital Baselland
Rehabilitation Guidelines for Knee Multi-ligament Repair/Reconstruction
UW Health Sports Rehabilitation Rehabilitation Guidelines for Knee Multi-ligament Repair/Reconstruction The knee joint is comprised of an articulation of three bones: the femur (thigh bone), tibia (shin
Achilles Tendon Repair, Operative Technique
*smith&nephew ANKLE TECHNIQUE GUIDE Achilles Tendon Repair, Operative Technique Prepared in Consultation with: C. Niek van Dijk, MD, PhD KNEE HIP SHOULDER EXTREMITIES Achilles Tendon Repair, Operative
LCP Olecranon Plate. The anatomical fixation system with angular stability for olecranon and proximal ulnar fractures.
LCP Olecranon Plate. The anatomical fixation system with angular stability for olecranon and proximal ulnar fractures. Surgical Technique This publication is not intended for distribution in the USA. Instruments
Expert TN. Tibial Nail.
Expert TN. Tibial Nail. Surgical Technique Expert Nailing System This publication is not intended for distribution in the USA. Instruments and implants approved by the AO Foundation. Image intensifier
LCP Compact Foot/Compact Hand.
LCP Compact Foot/Compact Hand. Surgical Technique This publication is not intended for distribution in the USA. Instruments and implants approved by the AO Foundation. Table of contents Indications 2
ACTIV ANKLE DISTAL AND DIAPHYSEAL FIBULA INNOVATION MEANS MOTION
ACTIV ANKLE DISTAL AND DIAPHYSEAL FIBULA POLYAXIAL LOCKING FIXATION DUALTEC SYSTEM II Precontoured implants Polyaxiality of 20 2 surgical approaches : lateral and posterolateral ACTIV ANKLE The ACTIV ANKLE
Corporate Medical Policy Computer Assisted Surgical Navigational Orthopedic Procedures
Corporate Medical Policy Computer Assisted Surgical Navigational Orthopedic File Name: Origination: Last CAP Review: Next CAP Review: Last Review: computer_assisted_surgical_navigational_orthopedic_procedures
VariAx Distal Radius Locking Plate System. Anatomical & Universal Volar Plates Dorsal Plates Fragment Specific Plates
VariAx Distal Radius Plate System Anatomical & Universal Volar Plates Dorsal Plates Fragment Specific Plates System Module The NEW VariAx Distal Radius Plating System represents the Next Generation of
ASOP Exams PO Box 7440 Seminole, FL 33775. The Manual of Fracture Casting & Bracing Exam 80% Passing ID # Name Title. Address. City State Zip.
The Manual of Fracture Casting & Bracing Exam 80% Passing ID # Name Title Address City State Zip Tel# Email Certification Organization Cert# Mail a copy of your completed exam to: ASOP Exams PO Box 7440
Proximal Hip Fracture Open Reduction/Internal Fixation and Rehabilitation
1 Proximal Hip Fracture Open Reduction/Internal Fixation and Rehabilitation Surgical indications and Considerations Anatomical Considerations: The hip is a ball and socket joint with the femoral head aligned
Non Operative Management of Common Fractures
Non Operative Management of Common Fractures Mr Duy Thai Orthopaedic Surgeon MBBS, FRACS (Ortho), Dip Surg Anat NOT ALL FRACTURES NEED TO BE FIXED FRACTURE CLINIC EMERGENCY DEPARTMENTS GENERAL PRACTITIONERS
The Knee: Problems and Solutions
The Knee: Problems and Solutions Animals, like people, may suffer a variety of disorders of the knee that weaken the joint and cause significant pain if left untreated. Two common knee problems in companion
We compared the long-term outcome in 61
Fracture of the carpal scaphoid A PROSPECTIVE, RANDOMISED 12-YEAR FOLLOW-UP COMPARING OPERATIVE AND CONSERVATIVE TREATMENT B. Saedén, H. Törnkvist, S. Ponzer, M. Höglund From Stockholm Söder Hospital,
Introduction to the Bertram Hip Spacer
Introduction to the Bertram Hip Spacer Approximately 200,000 hip replacement surgeries are done every year in United States. Fortunately the incidence of infection is routinely 0.5 percent-1 percent. However
