1 BORAL PLASTERBOARD Build something great Section 4 Wall Lining Solutions
2 4.1 SYSTEMS INTRODUCTION Boral Direct Bond Wall Lining System Boral Direct Bond Wall Lining System provides a fast, efficient means of creating flat seamless plasterboard walls over masonry substrates with minor irregularities and offers a dry solution calling for skills more easily acquired than traditional sand/cement rendering or plastering. Ideal for use in housing, apartments and commercial buildings. With more than 30 years of use as a housing system in the UK it continues to provide a highly cost-effective means of lining masonry walls and complying with UK Building Regulations. Boral PROframe TM Close-Fit Wall Lining System Boral Close-Fit Wall Lining System is an ideal solution for lining more severe irregular dry masonry walls with plasterboard. The system is simple, fast to install, cost effective and can easily accommodates both mechanical and electrical services. Typically used in commercial projects it also offers particular benefits in reducing sound flanking transmission through the path of masonry walls which Boral partitions join onto. Boral PROframe TM Independent Wall Lining The Boral Independent Wall Lining system is especially suited for lining reinforced concrete walls and steel framed walls, walls which have severe irregular surfaces, and external walls that have suffered damp ingress, but then treated with appropriate damp proofing systems. Fixed clear of the external wall, this system allows space for both mechanical and electrical services, or for high levels of thermal and acoustic insulation This system is commonly for applications ranging from factories and warehouses to hotels and multiplex cinemas.
3 PERFORMANCE TABLES - INTRODUCTION 4.2 Max Height (m) Boral Close-Fit Wall Lining System The maximum heights given in the tables refer to the background masonry construction limitation. For maximum height of Boral Close-Fit Wall Lining system on another type of masonry background contact Boral Technical Support Centre. Boral Independent Wall Lining System Maximum heights shown are without extra bracing supports and based on a deflection criteria of L/240 under a static UDL (Uniformly Distributed Load) of 0.25kPa. For independent wall linings at 4.2m or above, Boral Deep Flange U-Track and Boral Deflection Head Brace should be used at the wall lining head to ensure C-Studs remain in the U-Tracks in the event of a fire or during any design movement of the building. Fire Rating and Acoustics With many years of fire and acoustic testing around the world Boral has accumulated a wealth of expertise and knowledge together with a wide range of system test reports. Indicates that a test report is available Indicates a prediction based on expert opinions, test reports from other similar tests or specialist calculation software like Marshall Day. With added bracing supports greater heights may be achieved, for more information contact Boral Technical Support Centre. Example Of Tables System Reference BP WL 4 Description Masonry : 100mm brickwork Lining : Boral Universal Channels at 610mm maximum attached to Boral Close-Fit Brackets at 800mm max vertical Board : Insulation : One layer 13mm Boral dbstop plasterboard each side 25mm glass mineral wool, density 16 kg/m 3 MAX HEIGHT (m) ACOUSTICS (RwdB) FIRE RATING (minutes)
4 4.3 PERFORMANCE TABLES Boral Close-Fit Wall Lining systems for external walls System Reference BP WL 1 Description Masonry : Sand/cement render on solid 215mm concrete blockwork, density 2300Kg/m 3 Lining : Boral Universal Channels at 610mm maximum attached to Boral Close-Fit Brackets at 800mm max vertical Board : Insulation : 13mm Boral HeatSTOP plasterboard 50mm glass mineral wool, density 24 kg/m 3 MAX HEIGHT (m) ACOUSTICS (RwdB) FIRE RATING (minutes) System Reference BP WL 2 Description Masonry : 215mm brickwork Lining : Boral Universal Channels at 610mm maximum attached to Boral Close-Fit Brackets at 800mm max vertical Board : Insulation : 13mm Boral HeatSTOP plasterboard 50mm glass mineral wool, density 24 kg/m 3 MAX HEIGHT (m) ACOUSTICS (RwdB) FIRE RATING (minutes) Boral TM Close-Fit Wall Lining systems for internal walls System Reference BP WL 3 Description Masonry : 100mm brickwork Lining : Boral Universal Channels at 600mm maximum attached to Boral Close-Fit Brackets at 800mm max vertical Board : Insulation : 13mm Boral dbstop plasterboard None MAX HEIGHT (m) ACOUSTICS (RwdB) FIRE RATING (minutes) System Reference BP WL 4 Description Masonry : 100mm brickwork Lining : Boral Universal Channels at 600mm maximum attached to Boral Close-Fit Brackets at 800mm max vertical Board : Insulation : One layer 13mm Boral dbstop plasterboard each side 25mm glass mineral wool, density 16 kg/m 3 MAX HEIGHT (m) ACOUSTICS (RwdB) FIRE RATING (minutes) Note: The maximum heights given in these tables refer to the background construction. When using Boral Close-Fit Wall Lining system in conjunction with mineral wool, ensure a 10mm cavity between inner masonry and back of insulation. Performance values are for imperforate, jointed systems using only Boral components and installed to the Boral Plasterboard Philippines specification given. Any alterations may well impair the quoted performance criteria.
5 PERFORMANCE TABLES 4.4 Boral Independant Wall Lining systems System Reference BP WL 5 Description Masonry : 100mm brickwork or blockwork Lining : Board : Insulation : Boral back-to-back C-Studs at 610mm maximum Inner layer 13mm Boral FireSTOP HeatSTOP plasterboard. Outer layer 13mm Boral FireSTOP plasterboard. 100mm glass mineral wool, density 10.5 kg/m 3 System Reference BP WL 6 Description Outer leaf : Profiled metal cladding Lining : Board : Insulation : Boral back-to-back C-Studs at 610mm maximum Inner layer 13mm Boral FireSTOP HeatSTOP plasterboard,outer layer 13mm Boral FireSTOP plasterboard. 100mm glass mineral wool, density 10.5 kg/m 3 Systems BP WP 5 and BP WP 6 with back-to-back C-Studs Depth STUD SIZE (mm) Gauge MAX HEIGHT (m) Non-Load Bearing 406mm FIRE RATING (minutes) Note: Maximum heights shown are without extra bracing supports and based on a deflection criteria of L/240 under a static UDL (Uniformly Distributed Load) of 0.25kPa. For independent wall linings at 4.2m or above, Boral Deep Flange U-Track and Boral Deflection Head Brace should be used. With added bracing supports greater heights may be achieved, for more information contact Boral Technical Support Centre. Performance values are for imperforate, jointed systems using only Boral components and installed to the Boral Plasterboard Philippines specification given. Any alterations may well impair the quoted performance criteria.
6 4.5 DIRECT BOND WALL LINING SYSTEM Introduction Boral Direct Bond Wall Lining System Boral Direct Bond Wall Lining System provides a fast, efficient means of creating flat seamless plasterboard walls over masonry substrates with minor irregularities and offers a dry solution calling for skills more easily acquired than traditional sand/cement rendering or plastering. Ideal for use in housing, apartments and commercial buildings. This system is easy and quick to apply using bonding compound to bond up to 16mm thick Boral Standard Core, Boral dbstop or Boral FireSTOP plasterboard onto masonry substrates. Limitations This method of fixing is not recommended for solid external walls subject to the ingress of moisture. If ingress cannot be fully eliminated, then use the Boral PROframe TM Close-Fit Wall Lining System or Boral PROframe TM Independent Wall Lining System. Plasterboard limitation, Boral WetAREA, Boral WetAREA FireSTOP and Boral HeatSTOP plasterboards are not suitable for direct bonding and should be mechanically screw fixed using the Boral PROframe TM Close-Fit Wall Lining System or Boral PROframe TM Independent Wall Lining System. Height limitation, the maximum installation height for direct bond should not exceed 3 metres. Cavity limitation, the final cavity between masonry substrate and back of plasterboard can be a minimum of 10mm and a maximum of 30mm. Direct Bond Wall Lining System Main Components Plasterboard as Suitable Boral Plasterboards» Boral Standard Core» Boral FireSTOP» Boral dbstop» Boral MultiSTOP
7 DIRECT BOND WALL LINING SYSTEM 4.6 Application Substrate Pre-Treatment Some masonry substrates may require abrasion or pre-treatment with a PVAC, see Pre-Treatment Of Masonry Substrates table below. application Apply to the walls as shown opposite. Dabs should be 50 to 75mm wide, 250mm long, and 25mm in from the board edges to avoid bridging of joints by the compound. The contact area of the dabs must be at least 20% of the board area. Certain floor/ceiling constructions can allow the circulation of air behind the boards and air may also enter at junctions with partitions and door/window frames. This circulation can reduce the thermal performance of the wall. To reduce this risk apply continuous horizontal and vertical bands of around electrical sockets, windows, wall perimeters, junctions and door frames of linings to internal faces of external walls. A continuous band of Boral Premium Bond at the floor line will ensure a solid base for skirting board fixing. Electrical cables should be protected by conduit. Movement control joints Movement control joints are required in wall linings at intervals not exceeding 10 metres, and where the wall lining crosses or abuts a structural movement joint. Jointing Bonded plasterboards should not be jointed for 24 hours to allow bonding compound to fully harden. All joints to be taped and jointed as in this manual, refer to Section 7 - Finishing Solutions for further details. Direct Bondng Of 13mm and 16mm Plasterboard Direct Bondng Of 9mm Plasterboard Pre-Treatment Of Masonry Substrates Background Examples High suction backgrounds Low and medium suction masonry Dabs at 600mm vertical Dabs at 400mm vertical Typical Type Dabs at 540mm horizontal centre Dabs at 360mm horizontal Aerated or lightweight aggregate concrete blocks Common clay bricks and concrete blocks, high density clay and concrete blocks Smooth pre-cast concrete 60mm 60mm Pre-treatment PVAC bonding agent None Plasterboard as Plasterboard as Remover shutter oil and concrete contaminates. Abrade to form a rough surface and pre-treat with a PVAC bonding agent Very low suction backgrounds High strength concrete PVAC bonding agent Note: 1. Extremely smooth surfaces may require abrasion prior to PVAC treatment. 2. Surfaces must be free of mould, oil and dust. Contaminted surfaces may require chemical cleaning. 3. Painted surfaces and limestone skimmed surfaces are not suitable for direct bonding.
8 4.7 DIRECT BOND WALL LINING SYSTEM Direct Bond Floor Level Detail Direct Bond Ceiling Level Detail 25mm 50~75mm Boral Premium Bond at floor level to provide support and fixing background for skirting Plasterboard finished 5mm short of floor level and gap sealed with Fire Acoustic Sealant or an acrylic sealant if non-fire rated Boral Premium Bond around perimeter of wall 50mm 250mm External Corner Detail Internal Corner Detail Window Opening Detail Junction With Partition Detail Fire Acoustic Sealant or an acrylic sealant if non-fire rated Boral Expansion Bolt Boral C-Stud Window Opening Detail
9 CLOSE-FIT WALL LINING SYSTEM 4.8 Introduction Boral PROfame TM Close-Fit Wall Lining System Boral PROfame TM Close-Fit Wall Lining System is an ideal solution for lining more severe irregular dry masonry walls with plasterboard. The system is simple, fast to install and cost effective making it suitable for many internal applications. Typically used in commercial projects it also offers particular benefits in reducing sound flanking transmission through the path of masonry walls which Boral partitions abut. Boral PROfame TM Close-Fit Wall Lining System is fixed directly to the existing background, allowing a cavity between wall and back of plasterboard ranging from 20mm to 70mm. This system can therefore be used for all common lining applications: electrical services performance performance This system is also ideal for screw fixing of Boral plasterboards which can not be direct bonded: Boral WetAREA, Boral WetAREA FireSTOP and Boral HeatSTOP. Performance The selection of lining systems, insulation and boarding will depend on the wall height and the performance required for fire resistance, thermal and sound insulation: refer to performance tables on page 4.3 in this section. Close-Fit Wall Lining System Boral Universal Channel Main Components Boral J Channel Boral J Channel Boral Close-Fit Bracket Plasterboard as Boral Universal channel Boral Close-Fit Bracket Boral Smart Connector Boral Expansion Bolt Boral Screws (as appropriate) Add Components For fine and sound performance Insulation (as ) Fire Acoustic Sealant Boral Flat Strap used as fire stop on horizontal joints or as lightweight fixing support
10 4.9 CLOSE-FIT WALL LINING SYSTEM Close-Fit Wall Lining Detail 150mm Horizontal Boral J Channel above doorway cut and turned down 150mm and screw fixed onto vertical corner Boral J Channel as shown 610mm max Option 2 Boral J Channel Internal corners -2 option Option 1 Boral Universal Channel 800mm max Option 2 Boral Close-Fit Bracket Boral J Channel Boral J Channels used on external corners and at doorways Framing Centres Board Thickness (mm) Board width (mm) Horizontar Framing Centres (mm) Vertical Bracket Centres (mm) Jointing All joints to be taped and jointed as in this manual, refer to Section 7 - Finishing Solutions for further details. 13 and
11 CLOSE-FIT WALL LINING SYSTEM 4.10 Floor And Head Detail 10mm Deflection Head Detail Leave a 5~10mm gap above board and fill with Fire Acoustic Sealant Note: If no fire requirement an acrylic sealant can be used Boral J Channel fixed to suffit at 600mm maximum Leave a 15mm gap above board and fill with Fire Acoustic Sealant Boral Close-Fit Bracket fixed to background using Boral Expansion Bolt or appropriate fixings at 800mm vertical Plasterboard fixed to Boral Universal Channels and Boral J Channels Boral Universal Channel fixed to Boral Close-Fit Bracket using Boral Pan Head Self Tapping Screws Cut Boral Universal Channels 10mm shorter than the floor to ceiling height Note: Boral Universal Channels and plasterboard MUST NOT be fixed to the soffit J Channel to ensure deflection movement Boral Close-Fit Bracket fixed to background 100mm below soffit using Boral Expansion Bolt Screw fix Boral Universal Channels to Boral Close-Fit Bracket using Boral Pan Head Self Tapping Screws Boral J Channel fixed to floor at 600mm maximum Internal Corner Detail Leave a 5~10mm gap below board and fill with Fire Acoustic Sealant Note: If no fire requirement an acrylic sealant can be used External Corner Detail Boral J Channel Fire Acoustic Sealant or an Acrylic Sealant if non fire rated Boral Universal Channel set 50mm in from internal corn Boral J Channel Boral Universal Channel set 50mm in from external corner Junction With Partition Detail Boral J Channel Boral J Channel Movement Control Joint Movement control joints are required in wall linings at intervals not exceeding 10m or where the wall lining crosses or abuts a structural movement joint. Compressible packing Fire Acoustic Sealant or an Acrylic Sealant if non fire rated Boral Expansion Bolt Boral C-Stud Boral Universal Channel set 50mm in from partition Boral Universal Channel set 50mm in from the background movement control joint Boral Movement Control Bead stapled onto plasterboard using 13mm stainless steel staples at 150mm. Joint using Boral Premium Jointing compound
12 4.11 INDEPENDENT WALL LINING SYSTEM Introduction Boral PROfame TM Independent Wall Lining System Boral PROfame TM Independent Wall Lining system is especially suited for lining reinforced concrete walls and steel framed walls, walls which have severe irregular surfaces, and external walls that have suffered damp ingress, but then treated with appropriate damp proofing systems. Fixed clear of the external wall, this system allows space for both mechanical and electrical services, or for high levels of thermal and acoustic insulation. This system is commonly for applications ranging from factories and warehouses to hotels and multiplex cinemas. The system uses Boral I Studs or back-to-back Boral C Studs and Boral U Tracks as used in the Boral PROframe TM Partition systems. Glass mineral wool batts can be inserted into the framing to improve the thermal and acoustic performance of the system. Performance The selection of lining systems, insulation and boarding will depend on the wall height and the performance required for fire resistance, thermal and sound insulation: refer to performance tables on page 4.4 in this section. Jointing All joints to be taped and jointed as in this manual, refer to Section 7 - Finishing Solutions for further details. Independent Wall Lining System Main Components Boral U Track Boral C Studs (back-to-back) or Boral I Studs Boral U Track Boral C Stud Insulation as Plasterboard as Boral I Stud For wall linings at 4.2m or above, Boral Deep Flange U Track and Boral Deflection Head Brace should be used. Boral Screws (as appropriate) Boral Deep Flange U Track Boral Deflection Head Brace Add Components For fire wall linings For wall linings with Insulation For fixing support Fire Acoustic Sealant Boral Flat Strap Boral Insulation Hold Strap Insulation (as ) Boral Fixing Channel
13 INDEPENDENT WALL LINING SYSTEM 4.12 Independent Wall Lining Detail Boral U Track fixed to soffit and floor at 600mm maximum centre C Stud screw fixing back-to-back Boral back-to-back C Studs or Boral I Studs at maximum 610mm C Studs 50mm to 92mm Single screw fixing at 200mm 50mm Boral C Studs at wall ends Boral C Studs at openings 200mm Boral U Tracks fixed top and bottom to form openings with Boral C Studs above and below for fixing plasterboard 200mm C Stud 148mm Staggered screw fixing at 200mm 50mm 200mm 200mm Plasterboard as Insulation as Timber sole plate (if required for uneven floors) Head Detail 10mm Deflection Head Detail Boral Expansion Bolt Leave a 5~10mm gap above board and fill with Fire Acoustic Sealant Leave a 15mm gap above board and fill with Fire Acoustic Sealant Boral U Track Boral back-to-back C Studs or Boral I Studs cut 5mm shorter than floor to soffit height Insulation as Boral Deep Flange U Track 10mm gap allowance for deflection between Boral U Track and Boral Flat Strap Boral Flat Strap Boral back-to-back C Studs or Boral I Studs cut 10mm shorter than floor to soffit height Plasterboard as Minimum 10mm cavity Note: Boral back-to-back C Studs or Boral I Studs and plasterboard MUST NOT be fixed to the soffit Deep Flange U Tack to ensure deflection movement Note: if no fire requirement an Acrylic Sealant can be used in place of Fire Acoustic Sealant
14 4.13 INDEPENDENT WALL LINING SYSTEM Floor Detail Internal Corner Detail Minimum10mm cavity Plasterboard as Insulation as Boral back-to-back C Studs or Boral I Studs Fire Acoustic Sealant or an Acrylic Sealant if non fire rated Boral C Stud Boral U Track Leave a 5~10mm gap below board and fill with Fire Acoustic Sealant Note: If no fire requirement an acrylic sealant can be used Boral back-to-back Boral C Studs or Boral I Studs External Corner Detail Junction With Partition Detail Boral C Stud Fire Acoustic Sealant or an Acrylic Sealant if non fire rated Boral C-Stud Boral back-to-back C Studs or Boral I Studs Boral C Stud Movement Control Joint Detail Movement control joints are required in wall linings at intervals not exceeding 10m or where the wall lining crosses or abuts a structural movement joint. Door Or Window Detail Boral Metal Angle Compressible packing Boral C Stud Boral back-to-back C Studs or Boral I Studs Boral back-to-back C Studs or Boral I Studs Boral Movement Control Bead stapled onto plasterboard using 13mm stainless steel staples at 150mm. Joint using Boral Premium Jointing
FireWall. High performance fireresistant. FireWall. www.british-gypsum.com
FireWall FireWall High performance fireresistant wall system FireWall is a non-loadbearing wall which provides up to 240 minutes fire resistance. It is used in certain ground floor basement situations
More informationInstallation Details. D1 General D2 Walls D3 Ceilings D4 Reference. D Installation Details
D Installation Details D1 General D2 Walls D3 Ceilings D4 Reference D Installation Details D Contents D1 General Installation and Fastening Sequence for Steel Studs D1.1 Fastener Selection D1.3 D2 Walls
More informationC05. S03. P02 P08 FireWall. Including C05. S01. P02 Specialist partitions introduction
C05. S03. P02 P08 Including C05. S01. P02 Specialist partitions introduction C05 Specialist partitions Introduction Specialist partitions This section details specialist lightweight systems where high-security,
More informationSOUND INSULATION FOR EXTERIOR WALLS AND FACADE SYSTEMS
NOISE TECHNICAL FACT SHEET FACT SHEET 5 SOUND INSULATION FOR EXTERIOR WALLS AND FACADE SYSTEMS The sound insulation of exterior walls and roof-ceiling systems refers to their ability to reduce external
More informationRockwool Flexi Insulation Application Guide
Pitched roof Rafters InterMediate floors INTERNAL partitions external Framed walls separating floors Separating Walls Rockwool Flexi Insulation Application Guide Ground floor The perfect fit for any framed
More informationManual lifting and handling
Manual lifting and handling When installing British Gypsum products and systems care should be taken to ensure that appropriate methods of handling and lifting are adopted. The following guidance details
More informationCERTIFICATE OF APPROVAL No CF 5055 ARABIAN VERMICULITE INDUSTRIES
CERTIFICATE OF APPROVAL No CF 5055 This is to certify that, in accordance with TS00 General Requirements for Certification of Fire Protection Products The undermentioned products of 1 st Industrial Area,
More informationNRG 75 CRF NRG GREENBOARD WALL SYSTEM
NRG GREENBOARD WALL SYSTEM NRG Energy Efficient Building Systems is pleased to announce a revolution in lightweight cladding systems. NRG Building Systems is the first and only company to achieve CodeMark
More informationPART 1 GENERAL 1.1 SECTION INCLUDES
J-1 Section 09110 Long Form Specification INTERIOR METAL STUD FRAMING This section includes lightweight, usually 0.036 inch (0.9 mm) thick or lighter, non-axial load bearing metal stud framing including
More informationINTERIOR WALLS AND BASEMENTS CHOOSING THE RIGHT MEMBRANE FOR INTERIOR WALLS. Multi-Layer Technology provides increased strength.
INTERIOR WALLS AND BASEMENTS CHOOSING THE RIGHT MEMBRANE FOR INTERIOR WALLS Multi-Layer Technology provides increased strength. Specifically designed for interior applications. Compatible with most internal
More informationKnauf Aquapanel Interior. Tile Backing. Cement board for wet areas. Will not deteriorate in water. Easy to score and snap
Tile Backing Will not deteriorate in water Easy to score and snap Resistant to mould and mildew Knauf Aquapanel Interior Cement board for wet areas Knauf Aquapanel Interior Cement Board Drywall for Wet
More informationPartitioning & Ceiling Product Information
Partitioning & Ceiling Product Information tel + 44 (0) 1384 412448 fax + 44 (0) 1384 4494 email enquiries@drywallsteelsections.co.uk web www.drywallsteelsections.co.uk tel + 44 (0) 1384 412448 fax + 44
More informationHanson Building Products. precast basement solutions
Hanson Building Products precast basement solutions Hanson Building Products Basement Systems Add an extra dimension and combine the inherent flexible, structural and waterproof properties of concrete
More informationCavity Drain R20 is manufactured from1.0mm thick black high density polyethylene with studs approximately 20mm high.
CI/SfB Tn6 L6813 September 2013 RIW CAVITY DRAIN R20 R20 is manufactured from1.0mm thick black high density polyethylene with studs approximately 20mm high. Other systems are available for specific uses,
More informationSection 5.0. Basements. Wall insulated externally. Wall insulated internally. Ba02. Product: Polyfoam ECO Floorboard Ba01.
Section 5.0 Basements Wall insulated externally Product: Polyfoam ECO Ba01 Wall insulated internally Product: Polyfoam ECO Ba02 Basements Basements Basement design Waterproofing BS 8102: 2009 Code of practice
More informationInterior Walls below and above ground OLDROYD THE ULTIMATE WATERPROOF MEMBRANE SYSTEM
P r o d u c t a p p l i c a t i o n s a n d t e c h n i c a l i n f o r m a t i o n 2 below and above ground V OLDROYD THE ULTIMATE WATERPROOF MEMBRANE SYSTEM V The flexible, fast and cost-effective answer
More informationPB301 July 2009. Lightweight Building Solutions. Bushfire Protection. www.boral.com.au/bushfireprotection
PB301 July 2009 Lightweight Building Solutions Bushfire Protection www.boral.com.au/bushfireprotection Attached or adjacent within 6m roofed structures such as garages, carports, verandas and the like,
More informationSchlüter -KERDI-BOARD Substrate, structural panel, bonded waterproofing
Substrate, structural panel, bonded waterproofing The universal substrate for tiles Perfect covering No matter whether you work with mosaics or large format tiles, an absolutely level substrate with straight
More informationFIRE RATED GLAZING System Guide
SYSTEM GUIDE Issue date: 05-05-2015 Expiry date: 31-12-2016 System Guide Introduction Pyropanel Developments are specialists in fire rated glazing solutions, and our systems are designed for easy installation
More informationH-Stud Area Separation Wall System
12 TH EDITION 09 21 16.33/NGC H-Stud Area Separation Wall System 09 21 16.33 139 H-STUD AREA SEPARATION WALL SYSTEM The fire-protection of gypsum-based Area Separation Walls is demonstrated in dramatic
More informationFire 2This Technical Bulletin has been commissioned by the UK SIP Association in
REV 1-12.12.11/TB002 Technical Bulletin Fire 2This Technical Bulletin has been commissioned by the UK SIP Association in conjunction with TRADA Technology and is intended to provide the reader with introductory
More informationPASSIVE FIRE PROTECTION SYSTEMS Application & Technical Manual: Ceilings & Floors
PASSIVE FIRE PROTECTION SYSTEMS Application & Technical Manual: Ceilings & Floors For distribution in Asia Pacific PASSIVE FIRE PROTECTION SYSTEMS Application & Technical Manual: Ceilings & Floors Contents
More informationENVIRONMENTAL INFORMATION APR 1200 products are made from glass mineral wool, one of the most environmentally friendly insulants available.
APR 1200 Acoustic Partition Roll CI/Sfb Ref: APR002 Glass mineral wool roll designed to provide high levels of sound insulation in walls and floors to meet Part E (England & Wales) and Section 5 (Scotland)
More informationFERMACELL Powerpanel H 2 O for Wet & Moisture affected areas
FERMACELL Powerpanel H 2 O for Wet & Moisture affected areas Powerpanel H 2 O is a cement based board from FERMACELL. Board Characteristics Board Thickness 12.5 mm Board Sizes 1000 x 1200 mm 50 sheets/pallet
More informationCover: Houghton Estate, luxury residential estate This page: Protea Hotel, Umhlanga Ridge
For Walls 1 Cover: Houghton Estate, luxury residential estate This page: Protea Hotel, Umhlanga Ridge Mass per m 2 CTN BPN Overview Description Gyproc RhinoBoard is manufactured according to the ISO 9001
More informationClad Direct Glaze Window Installation Instructions
Clad Direct Glaze Window Installation Instructions Sill flashing and sealing: 2. An overview of the proper flashing sequence is shown in figure 1. Please read entire installation instructions carefully
More informationInternal wall insulation in existing housing
Energy Efficiency Best Practice in Housing Internal wall insulation in existing housing A guide for specifiers and contractors Cost-effective External wall appearance maintained Easier to install and maintain
More informationWindow Installation Instructions
Caution The correct installation methods of windows in full frame or insert applications is critical towards achieving the tested performance of the window and longterm enjoyment and energy savings for
More informationSTRUCTURAL CONCEPT FOR LIGHT GAUGE STEEL FRAME SYSTEM
Chapter 9 STRUCTURAL CONCEPT FOR LIGHT GAUGE STEEL FRAME SYSTEM 9.1 BACKGROUND Steel is widely used in the construction of multi-storey buildings. However, steel construction is seldom used and is traditionally
More informationInstallation Window Building In Details
Installation Window Building In Details INSTALLATION Photo courtesy of Rowe Aluminium DATE: NOVEMBER 2009 REPLACES: AUGUST 2003 INSTALLATION Installation Replaces: Scale: NOT TO SCALE Vantage snap-on couplers
More informationUnderstanding BS EN 771-3: Aggregate concrete masonry units
60 Charles Street, Leicester LE1 1FB Tel: 0116 253 6161 Fax: 0116 251 4568 Email: enquiries@cba-blocks.org.uk Website: www.cba-blocks.org.uk February 2006 Understanding BS EN 771-3: Aggregate concrete
More informationEnergy Company Obligation (ECO): Technical Monitoring Questions
Energy Company Obligation (ECO) Technical Monitoring Questions v1 30/05/2013 Energy Company Obligation (ECO): Technical Monitoring Questions Under ECO suppliers are required to instruct suitably qualified
More informationLinea Weatherboard DIRECT FIX CONCRETE SLAB AND SOFFIT FIGURE 1
Top plate Stud Soffit lining 45mm min nog Fix scotia bead Building underlay/james Hardie rigid air barrier Soffit Detail Building underlay/james Hardie rigid air barrier Bottom plate 25mm wide cant strip.
More informationSection 4.3. Separating Floors. Timber frame floor with I-Beams. Upgrading existing timber floor with new ceiling. Timber frame floor with
Section Separating Floors Timber frame floor with I-Beams Product: Earthwool Acoustic Roll and Floorfoam Easy Edge Strip Timber frame floor with solid timber joists Product: Earthwool Acoustic Roll and
More informationInstallation Instructions
Installation Instructions 1. Position the unit onto bridging packers. These keep the unit away from any water sitting inside the frame. 2. Centralise the unit within the frame and pack the edges with appropriate
More informationModule 3.7. Thermal bridging
Module 3.7 Thermal bridging Learning Outcomes On successful completion of this module learners will be able to - Describe construction details which influence thermal bridging. 2 Introduction to thermal
More informationIMPACT DAMAGE RESISTANT WALL SYSTEMS
IMPACT DAMAGE RESISTANT WALL SYSTEMS CONTENTS Introduction 2 Advantages 2 2 Material Specifications 2 Design Considerations 3 Framing 5 Plasterboard Installation 5 Health, Safety & Warranty 6 Contact Details
More informationContents. APA Construction Details. Full fill cavity walls 2-13. Partial fill cavity walls 14-25. Solid externally insulated walls 26-37
Contents Pages Full fill cavity walls 2-13 Partial fill cavity walls 14-25 Solid externally insulated walls 26-37 Appendix (BRE confirmation of Ψ and y-values) 38-40 Page 1 of 40 APA Construction Details
More information7. Installation. installation 7.1.1. CAST-IN WINDOW SYSTEM 7.1. INSTALLATION OF WINDOW MAIN FRAME
7. Installation Window involves the fixing of window frame at an earlier construction stage and subsequent of the window sashes. This is a highly workmanship dependent process. Only trained and approved
More informationSection 3.1.2. Timber Frame Walls. Single layer between studs. Single layer between studs with service void. Between studs with insulated lining
Section Timber Frame Walls Single layer between studs Product: Earthwool FrameTherm Rolls and Slabs Tf01 Single layer between studs with service void Product: Earthwool FrameTherm Rolls and Slabs Tf02
More informationTunnels & Arches OLDROYD THE ULTIMATE WATERPROOF MEMBRANE SYSTEM
P r o d u c t a p p l i c a t i o n s a n d t e c h n i c a l i n f o r m a t i o n 5 Tunnels & Arches V OLDROYD THE ULTIMATE WATERPROOF MEMBRANE SYSTEM V Create dry usable space with the original X pattern
More informationComposite Panel Firewall Systems
Composite Panel Firewall Systems part of the Protecting more than your business Insulated mineral fibre panels have excellent thermal and acoustic properties, ideal for factory and office partition walls.
More informationImproving the flood resistance of your home. Advice sheet 4: Flood-resilient walls.
Improving the flood resistance of your home Advice sheet 4: Flood-resilient walls. This sheet provides guidance on identifying different types of wall, and reducing the flow of floodwater through them
More informationPANELIZED HOME INSTALLATION GUIDELINE
PANELIZED HOME INSTALLATION GUIDELINE A typical home package will be constructed of Snap-N-Lock Insulated Panels clad with steel skins. 4" panels will be used for the walls, and 6" panels for the roof.
More informationGuidelines for Earthquake Bracing Residential Water Heaters
Guidelines for Earthquake Bracing Residential Water Heaters Department of General Services Division of the State Architect In accordance with the Health and Safety Code Section 19215, the Division of the
More informationMarch 14, 2007. Installation of Bay, Bow and Garden Windows
March 14, 2007 Re: Installation of Bay, Bow and Garden Windows Attached are the Atrium Companies, Inc recommendation for the installation of bay, bow and garden windows. These instructions were developed
More informationEnvelope INSULATION BATT (2) Avoid Using Batt Insulation With Metal Framing. Pressure or Friction Fit
R-H-DI1 INSULATION BATT NR-E-IB1 Avoid Using Batt Insulation With Metal Framing Batt insulation should not be used with metal framing systems. Although it is common to see fiberglass batt insulation installed
More informationfirst look at GigaCrete s revolutionary new New Construction GigaHouse GigaHouse Utilizing GigaPanel
first look at GigaCrete s revolutionary new New Construction GigaHouse GigaHouse Utilizing GigaPanel What is GigaCrete GigaCrete is a family of products based on low carbon footprint Green ceramic binders
More informationCERTIFICATE OF APPROVAL No CF 291 SCHOTT UK LIMITED
CERTIFICATE OF APPROVAL No CF 291 This is to certify that, in accordance with TS General Requirements for Certification of Fire Protection Products The undermentioned products of Drummond Road, Stafford.
More informationDIY GUIDE 10 EASY STEPS FOR TREATMENT OF RISING DAMP
DIY GUIDE 10 EASY STEPS FOR TREATMENT OF RISING DAMP CONTENTS WHAT IS RISING DAMP STEP 1 SURVEY STEP 2 METER READINGS STEP 3 CONCLUSION STEP 4 PREPARATION FOR TREATMENT STEP 5 TYPE OF TREATMENT STEP 6
More informationServices Enclosures and Protected Shafts - Maintaining Compartmentation
Introduction When a fire resisting element is used to provide fire compartmentation, every opening that allows services to pass through the element must be adequately protected by sealing, or fire stopping
More informationBEST PRACTICE GUIDE. Fibrelime Premixed Universal Plaster and Render
BEST PRACTICE GUIDE Fibrelime Premixed Universal Plaster and Render Contents: Fibrelime description Fibrelime suitability Preparation before application Application Aftercare Painting General Recommended
More informationWINDOW INSTALLATION GUIDE FOR NEW CONSTRUCTION - WOOD FRAMING
WINDOW INSTALLATION GUIDE FOR NEW CONSTRUCTION - WOOD FRAMING IMPORTANT NOTICES AND INFORMATION Read these instructions in their entirety prior to installing windows. Any local building code requirements
More informationTechnical Data Sheet W13. Edition 2005-03. Knauf Fire Walls
Technical Data Sheet W13 Edition 2005-03 Knauf Fire Walls Knauf Fire Wall A2 - GKF two/ three layer cladding Knauf Fire Wall A1 - Fireboard two layer cladding The structural, statical properties, and characteristic
More informationGypsum Board Systems Manual
CertainTeed Gypsum Board Systems Manual Fire Resistance and Sound Control Design Manual Division 09 GYPSUM BOARD SYSTEMS MANUAL TABLE OF CONTENTS Introduction General Fire Resistance...1 Sound Control...3
More informationCertainTeed. Shaftliner For A rea Separation Firewalls
CertainTeed Shaftliner For A rea Separation Firewalls M2Tech Shaftliner Type X for Area Separation M2Tech Shaftliner is a specially formulated product for applications where enhanced mold resistance is
More informationFSD35, FSD36 AND FSD37 COMBINATION FIRE and SMOKE DAMPERS
3900 Dr. Greaves Rd. Kansas City, MO 64030 (816) 761-7476 FAX (816) 765-8955 INSTALLATION INSTRUCTIONS FSD35, FSD36 AND FSD37 COMBINATION FIRE and SMOKE DAMPERS 11/2 HOUR UL555 RATED UL555S LEAKAGE RATED
More informationThe better way to build TM. Installation Manual. EXTERIOR WALL SIPs
The better way to build TM Installation Manual EXTERIOR WALL SIPs July 2015 EXTERIOR WALL SIPs Installation Manual Table of Contents Topics General Requirements................................... 3 Materials..............................................
More informationGuidelines for Earthquake Bracing of Residential Water Heaters
Guidelines for Earthquake Bracing of Residential Water Heaters Department of General Services Division of the State Architect 1102 Q Street, Suite 5100 Sacramento, CA 95814 Phone: (916) 324-7099 Fax: (916)
More informationIf stepping is required, step at 180mm as seen in this picture.
Cast Foundations to standard building regulations requirements. Foundations must be cast completely level, 600mm wide by 230mm deep for single storey, double storey is not allowed by NHBRC. If stepping
More information12.1 Schlüter -KERDI-BOARD
I n n o v a t i v e p r o f i l e s 12.1 Schlüter -KERDI-BOARD S u b s t r a t e U N I V E R S A L S T R U C T U R A L P A N E L, B O N D E D W A T E R P R O O F I N G Application and Function Schlüter
More informationGYPSUM AREA SEPARATION FIREWALLS GA-620-2011
GYPSUM AREA SEPARATION FIREWALLS GA-620-2011 GA-620-2011 Copyright 2011 Gypsum Association All rights reserved. Printed in U.S.A. Characteristics, properties, or performance of materials or systems herein
More informationVA25014B0516 VA CINCINNATI PROJECT NO. 539-328 INPATIENT BED TOWER ADDITION (4 TH AND 5 TH FLOORS) SECTION 09 29 00 GYPSUM BOARD
SECTION 09 29 00 GYPSUM BOARD PART 1 - GENERAL 1.1 DESCRIPTION This section specifies installation and finishing of gypsum board, vapor retarder and air and moisture barrrier. 1.2 RELATED WORK A. Installation
More information0331 Brick and block construction
0331 BRICK AND BLOCK CONSTRUCTION This worksection has been written for Class 1 and 10a buildings that fully conform to the scope of AS 4773.1. If the works include isolated structures, (totally separate
More informationDIVISION 8, METAL SOUND CONTROL DOOR ASSEMBLIES PART 1 GENERAL 1.1 RELATED DOCUMENTS
DIVISION 8, METAL SOUND CONTROL DOOR ASSEMBLIES PART 1 GENERAL 1.1 RELATED DOCUMENTS Drawings and general provisions of the contract, including general and supplementary conditions and other Division 1
More informationIRISH BUILDING CONTROL INSTITUTE HOTEL COURT HOTEL BALLYCONNELL CO CAVAN. 26 th MARCH 2009 TIMBER FRAME CONSTRUCTION
IRISH BUILDING CONTROL INSTITUTE HOTEL COURT HOTEL BALLYCONNELL CO CAVAN 26 th MARCH 2009 TIMBER FRAME CONSTRUCTION Bill Robinson BSc. C. Eng. M. I. Struct. E. Timber Design Services 1 IS440 Timber frame
More informationIntroduction...COMB-2 Design Considerations and Examples...COMB-3
SECTION DIRECTORY General Information Introduction...COMB-2 Design Considerations and Examples...COMB-3 Combination Assembly Recommendations and Limitations Composite Configurations...COMB-4 Typical Sealant
More informationWELCOME. Recommended Window Installation. 1.5 credits Minnesota Department of Labor and Industry
WELCOME Recommended Window 1.5 credits Minnesota Department of Labor and Industry In accordance with the Department of Labor and Industry s statute 326.0981, Subd. 11, This educational offering is recognized
More informationDubai Municipality Standard DMS 1: Part 5: 2004
Specification for precast concrete blocks Part 5: Normal-weight concrete-polystyrene sandwich masonry blocks Issue Date Revision Revision Description Prepared by Approved by Authorized by 19/12/2004 Issue
More informationFiberglas, Exterior Wall Thermal Insulation
PROJECT ENGINEER RESPONSIBILITY: This is a general specification guide, intended to be used by experienced construction professionals, in conjunction with good construction practice and professional judgment.
More informationPassive Fire Protection
Firestopping Passive Fire Protection FS20 Firestop Compound 6 hour fire rated penetration seals for electrical and mechanical services FS20 Firestop Compound FS20 Firestop Compound is a Fire-Rated Penetration
More informationSchluter -KERDI-BOARD Substrate, building panel, bonded waterproofing
Schluter -KERDI-BOARD Substrate, building panel, bonded waterproofing Schluter -KERDI-BOARD The universal substrate for tiles Flat. Level. Plumb. Square. No matter the quality, cost, or extravagance of
More informationGood Craftsmanship Guide. Carpentry and Joinery- Carcassing
Good Craftsmanship Guide Carpentry and Joinery- Carcassing Introduction This Good Craftsmanship Guide highlights key problems with the major elements of Carpentry and Joinery - Carcassing, and gives guidance
More information!!!!!! !!! Decra Plus DPSW010 DPSTW011 DPSW012 DPSW013 DPSW014 DPSW015 DPSW016 DPSW020 DPSW021 DPSW024 DPSW030 DPSW031 DPSW035 DPSW030 DPSW031 DPSW035
Decra Plus Drawing no DPSW010 DPSTW011 DPSW012 DPSW013 DPSW014 DPSW015 Description Shown In Decra Brochure Most Commonly Used Detail t~êã=oççñ=b~îéë=aéí~áä=b~îéë=lîéêü~åö=táíü=fåëìä~íéç=c~ëåá~=~åç=pçññáí
More informationThe WANZ Guide to Window Installation
The WANZ Guide to Window Installation as described in E2/AS1 Amendment 5 Ver. 1.1 Page 2 of 74 Contents Overview Page 5 Objective Page 5 Scope Page 5 Opening Preparation Page 7 Step P1 Preliminary Check
More informationWe urge you to read and follow the attached installation instructions. Failure to do so may void the warranty of this garden window unit.
Important Information for New Construction Installations Attention Installer! We urge you to read and follow the attached installation instructions. Failure to do so may void the warranty of this garden
More informationnecessary for years of satisfactory service. SmartBlock insulating form concrete walls share the
Chapter 7 PLUMBING AND ELECTRICAL 7.1 Introduction to Plumbing and Electrical Consideration of support services such as plumbing and electrical systems from the preliminary schematics phase through final
More informationTFL CUSTOM FIREPLACES WITH MASONRY BRICK LININGS. standard INSTALLATION SPECIFICATION INTO TIMBER FRAMING
6.CW.1A TFL CUSTOM FIREPLACES WITH MASONRY BRICK LININGS wood or gas standard INSTALLATION SPECIFICATION INTO TIMBER FRAMING The Fireplace Ltd is able to design and fabricate custom brick open masonry
More informationGigaCrete Specification PlasterMax
GigaCrete Inc. 6775 Speedway Blvd. Suite M105 Las Vegas, NV 89115 Ph (702) 643-6363 Fax (702) 643 1453 www.gigacrete.com GigaCrete Specification PlasterMax PlasterMax : Fire Rated Plaster for Direct Application
More informationMonocouche Best Practice Guide. New-Build Housing Managing movement to avoid cracking
Monocouche Best Practice Guide New-Build Housing Managing movement to avoid cracking Avoiding Cracking For The Designer Visible cracks in render are unsightly and although not hazardous to the construction
More informationInstallation information. METTLER TOLEDO MultiRange DW150 / DW150T wall scale
Installation information METTLER TOLEDO MultiRange DW150 / DW150T wall scale DW150 / DW150T wall scale Contents Contents Page 1. Installation... 2 1.1 Preparatory work... 2 1.2 Installing the wall plates
More informationTimber Frame Construction
Timber Frame Construction Introduction Design and Detailing What is timber? Failure modes History of timber frame construction Forms of timber frame construction Live and dead loads Wind loads Roof construction
More informationMulti-layer Insulation Blanket for Roofs
Multilayer Insulation Blanket for Roofs Thermal Insulation in a 40mm thin, flexible, multilayer membrane Meets requirements of L1A, L1B 2010 In accordance with BR443 NHBC Acceptance Pitched & Flat roof
More informationCHARISMA SHOWER/TUB DOOR INSTALLATION INSTRUCTIONS
CHARISMA SHOWER/TUB DOOR INSTALLATION INSTRUCTIONS IMPORTANT DreamLine reserves the right to alter, modify or redesign products at any time without prior notice. For the latest up-to-date technical drawings,
More informationThe right solutions. However, it is inevitable that with the introduction of any new construction system the question arises How does it compare?
Value assessment. The right solutions. We Believe We believe that Porotherm offers both short and long term value to all involved in the building process - from bricklayer to client and everyone in between.
More informationsound reduction systems for commercial, educational and industrial environments
sound reduction systems for commercial, educational and industrial environments Tel: +44 ()14 3874 Fax: +44 ()14 38957 E-mail: info@soundreduction.co.uk Web: www.soundreduction.co.uk soundblocker Acoustic
More informationRockwool Cladding Roll
Rockwool Cladding Roll High performance industrial insulation has been specifically developed for use in lightweight cladding applications to commercial or industrial framed buildings. Cladding Roll U/F
More informationTimber Decks. Technical Note. March 2007
Timber Decks Technical Note. March 2007 This Technical Note contains general information for residential timber decks and floor frame structures for veranda s, patios etc which are exposed to the weather.
More informationrationel WINDOWS WITH VISION
Brick / Blockwork 340mm Cavity Wall Interface Detail Cill BW-001A 5 x 50mm Woodscrews (Staggered) By Installer 20 x 90mm Standard Timber Packer With Upstand Bedded To Frame In Silicone By Installer Aluminium
More informationSTAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM
STAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM Installed in Pre-engineered Steel Buildings Provides Lowest Cost Construction Method for CORROSIVE AND WET Environments PREFERRED SOLUTIONS, INC.
More informationSports Buildings: budget costs for the Flood Relief Fund
Sports Buildings: budget costs for the Flood Relief Fund The list below provides typical costs for flood insurance works, typically required by sports clubs or facilities. The list is not exhaustive but
More informationBaumit Renders for Porotherm Masonry. Application Guidelines. n Light and easy application n Tried and tested
Renders for Porotherm Masonry Application Guidelines n Light and easy application n Tried and tested Porotherm is a Wienerberger Group brand Ideas with a future Renders for Porotherm Masonry International
More informationSteel-framed Walls. Insulation
Insulation A4/8 SF AW1192 Issue 4 Nov 2012 Steel-framed Walls Insulation guide Helps achieve a 6-star house energy rating Rigid and flexible Kingspan AIR-CELL solutions available Vapour barrier or vapourpermeable
More informationPost and Beam Construction
Post and Beam Construction A Presentation By the Canadian Wood Council Canadian Conseil Wood canadien Council du bois Early settlers introduced the concept of post and beam construction in North America
More informationFig. 2 WALL-TO-WALL PANEL CONNECTIONS CORNER WALL CONNECTION
SIPS SCREWS WITH MINIMUM 1" PENETRATION IN WOOD MEMBER IN SIP WALL PANEL CONNECTED TO @ 24" O.C. MAXIMUM OUTSIDE SKIN EACH SIDE OF FRAMING TYP. AS RECOMMENDED BY FOAM CORE AS EACH SIDE OF FRAMING TYP.
More informationThe WANZ Guide to Window Installation
The WANZ Guide to Window Installation as described in E2/AS1 Amendment 5 2 of 60 Contents Overview 5 Objective 5 Scope 5 Opening Preparation 7 Step P1 Preliminary Check 8 Step P2 Cut the Underlay 9 Step
More informationStorage Store the siding in a dry and ventilated area. Do not place it directly on the ground. Always cover the siding after a day s work.
Installation Guide Before you begin, take the time to read this entire guide to clearly understand the requirements and steps to follow for proper installation. Warning Do not install defective material.
More informationDE Frame with C Series Sidelight
TOOLS REQUIRED Tape measure 6' magnetic level 3' magnetic level Screw gun with clutch adjusted #2 phillips tip #3 phillips tip Screwdriver (used to adjust frame on will using oval slots) Pry Bar Powder
More informationINSTALLATION INSTRUCTIONS IMPERVIA (Vent and Fixed) AWNING, CASEMENT, and LARGE AWNING WINDOW WITH FINS
2009 Pella Corporation INSTALLATION INSTRUCTIONS IMPERVIA (Vent and Fixed) AWNING, CASEMENT, and LARGE AWNING WINDOW WITH FINS Part Number: 80WH0100 Installation Instructions for Typical Wood Frame Construction.
More information