1 REQUIREMENTS FOR SINGLE FAMILY DWELLING ADDITIONS Submittal: Two (2) sets of reproduction (copy or blue-print) plans are required to be submitted for plan check. Plans shall be drawn to scale with a straight edge and of sufficient clarity and detail to show conformance with all relevant laws and ordinances. Planning Department (Room 208) : Approval is required for a room addition prior to submitting plans to the Building and Engineering Department. The minimum requirement is a plot plan, a floor plan, and elevations. Planning phone number: (626) Building and Engineering (Room 215): In addition to the above, structural plans (and calculations for most second stories), details, and energy conservation requirements are required. A separate permit is required for building, plumbing, mechanical, and electrical. A formal fee quote is available upon request. Basic Plan Requirements - Refer to specific samples. PLOT PLAN: a) A site plan showing all lot dimensions, north arrow, scale, streets, alleys and easements. b) The exact location, setbacks, and dimensions of all existing and proposed structures on the lot including patios, accessory buildings, and pools. Show distances between adjacent buildings and buildings and the property lines. Show the size and location of any trees affected by the proposed construction. c) The location and dimensions of all proposed new construction, with all proposed construction clearly identified. d) A summary showing a description of the proposed project, lot size, existing, proposed, demolished, and total area in square feet, the number of stories and the current building code. (2007CBC) e) The site address, the owner s name, and the name of the designer or other consultants. A copy of the site plan is required to be submitted on an 8-1/2 by 11 or 14 size sheet of paper. FLOOR PLAN a) The exact location and dimensions of all existing and proposed rooms. All rooms shall be clearly identified by use such as kitchen, bedroom, closet, etc. b) Show the size, type and location of all proposed windows, existing windows removed, and windows of rooms affected by or adjacent to the addition. Required window area must be between 8% and 20% of the floor area of the room and be 1/2 openable in most cases. Each sleeping room shall have one emergency egress opening directly to the outside. Ask for specific requirements. c) Show all other code-related requirements such as smoke detectors, door sizes, landings, stairs, rise and run, handrails, guardrails, safety glazing, and security requirements. Roof coverings shall be at least Class B fire rated. Show under-floor and attic access and ventilation. Show all wall, floor and ceiling insulation. ELEVATIONS Must be drawn to scale, showing building height, exterior materials, and the locations of doors, windows, exterior stairs, chimneys, facia, eaves, cornices, wall facings, brickwork, and any other architectural features. STRUCTURAL PLANS a) A foundation, floor framing (when required), and a roof framing plan is required to show all footings, anchor bolts, rebar, sills, rafters, joists, ridges, beams, headers, supports, and span and spacing of members. b) Clearly detail all conditions that do not conform to the standard framing shown on a type five sheet. c) Clearly show wall bracing such as plywood or stucco. Usually at least 4 feet every 25 feet is required. Engineering is Required for any structure not conforming to the conventional light, wood framing and bracing requirements of UBC Section Examples of some projects requiring engineering are: unusual or irregular shapes or sizes, second stories, vaulted ceilings, long span beams (over 16 feet), and structural steel. Structural plans and calculations are required to be prepared under the direction of a California State Professional Engineer or Architect and stamped and signed upon submittal. (rev )
2 SAMPLE PLOT PLAN FOR SINGLE FAMILY DWELLING ADDITIONS A plot plan is required for any single family addition or alteration involving a change to the site. A plot plan is required to be submitted on letter or legal size paper (8-1/2 x 11 or 8-1/2x14). Submit two (2) reproduction copies as part of your permit application. (rev ) Use this example as a guide to draw your own plot plan. Show as much information as possible. Plans shall be drawn to scale, with a straight edge, and with enough clarity to show conformance with applicable regulations. Actual conditions and requirements may differ from this example. Side Yard Set Back 8 10 N.Patio (8 x10 ) 80ft. PL Rear Yard Set Back 30 Addition (30 x25 ) 25 Project Data (For example only) Owner: Mr. & Mrs. Citizen Address: 1234 Street Name Designer: By owner Description: Addition of bedroom, bathroom, and patio Building Code Occupancy: R-3 (single family) Type of Construction: V-N Code: 2007 CBC 100 ft. PL Ex. House Ex. Garage Drive- Way Ex.Porch 80 ft. PL d/w approach Sidewalk Front Yard Set Back Face of Curb Side Yard Set Back Parkway Width Area (s.f.): Dwelling 1450 Garage 400 Porch 80 Subtotal 1930 Area (s.f.): Dwelling 750 Patio 80 Subtotal 830 s.f. Grand Total (s.f.) 2760 Lot Size: 100 x 80 =8000 s.f. Lot Coverage = 2760/8000 = 34.5 % Allowable Coverage =35 % (ok) 34.5% < 35% Street Name N Scale: 1-0 = 20-0 Fire Hydrant
3 Incorporated W, Garvey - (626) Sample Floor Plan for Single Family Dwelling Additions A floor plan is required as part of the submittal for the permit application for any single family addition or alteration. Submit two (2) reproduction copies of the complete set of plans as part of your permit application. Use this example as a guide to draw your own floor plan. Clearly distinguish between all new, existing and removed walls, construction, and other features such as windows. Include all adjacent rooms and any other room affected by the new construction. Provide dimensions of all walls, room sizes, doors, and windows. Verify windows meet light (min. 8% of floor area), ventilation (min. 4% of floor area), and egress size requirements. Show as much information as possible. Plans shall be drawn to scale, with a straight edge, and with enough clarity to show conformance with applicable regulations. Actual conditions and requirements may differ from this example. (say/addnfloorplan/021308) x4 0 Sliding Window (44 sill) Open Patio Cover (8 x10 ) 4 0 x6 0 Slidg. Window Hall Bedroom (30 x17 = 510 s.f.) Walk- In Clos. Bathrm. 24 min. Clos. Remove and Fill Ex. Kitchen ( No Changes) 30 x30 attic access Window Ex. Bed Room (18 x16 =288 sf) 3 0 x6 8 Door (typ) Fan (5 air Ch. per Hr.) 30 min. Ex. 5 0 x6 0 Sliding Window (44 sill ht.) Legend = Hard-wired (may be battery in existing) smoke detector w/ battery back-up Ex. Living Room (No Changes) Hall Ex. Bath- Room Ex. B.R.. Wall Wall Demo Window
4 SAMPLE ELEVATIONS FOR SINGLE FAMILY DWELLING ADDITION ELEVATIONS Must be drawn to scale, showing building height, exterior materials, and the locations of doors, windows, exterior stairs, chimneys, facia, eaves, cornices, wall facings, brickwork, and any other architectural features. (rev ) Class B Dimensional Comp Shingles Finish floor to be +6 above finish grade or finish surface East Elevation Scale: 1/8 = 1 0 2x8 wood facia to match existing Stucco to match existing Class B Dimensional Comp Shingles Roof slope: 4 in 12 Attic vents Patio 4x4 posts, 4x10 beams, and 3x3 trellis at 10 o/c. See Patio handout. Stucco Ex. Sliding Glass door 8 x 4 sliding window Weep screed +4 above earth and 2 above paving typ. Stucco to match existing North Elevation Scale: 1/8 = 1 0 attic vent windows +9 0 Eave 18 typical 4 x6 Sliding Window Patio West Elevation Scale: 1/8 = 1 0
5 SAMPLE STRUCTURAL PLANS FOR SINGLE FAMILY DWELLING ADDITIONS STRUCTURAL PLANS (Scale min.! = 1 ) a) A foundation, floor framing (when required), and a roof framing plan is required to show all footings, anchor bolts, rebar, sills, rafters, joists, ridges, beams, supports, and span and spacing of members. Framing sections may be required. b) Clearly detail all conditions that do not conform to the standards shown on the type V sheet. c) Clearly show wall bracing such as plywood or stucco. At least 4 feet every 25 feet is required. Engineering is Required for any structure not conforming to the conventional light, wood framing and bracing requirements of CBC Section Examples of some projects requiring engineering are: unusual or irregular shapes or sizes, second stories, vaulted ceilings, long span beams (over 16 feet), and structural steel. Structural plans and calculations are required to be prepared under the direction of a California State Professional Engineer or Architect and stamped and signed upon submittal. (addn.framing/021308) slab 4 slab o/ w.w.m.f. 5/8 diameter x 10 min. long anchor bolt w/ 2 x2 x3/16 sq washer 4 o/c, w/ 7 embed. at single pour! gyp.bd. #4 rebar top and bottom Foundation Plan 3 clear A galv. stucco weep screed is required 4 above earth and 2 above conc wide footing, see detail C 12 -#4 rebar dowel new to exist top and bottom 2x4 stud at 16 o/c 2x4 p.t. sill Stucco o/ (2) bldg. paper o/ plywood 8 above f.g. or f.s. 12 below nat. soil Detail C Class B comp shingles o/ (2)-15# felt, o/ 1/2 cdx plywood w/ 10d at 6 &12 See standard patio plan roof Strap top plates to Ex. 2x8 Roof rafters at 16 o/c 2x8 Ceiling joist at 16 o/c! cdx plywd. 5-16d nails A35 48 oc R-13 Ins. R-19 Ins. See type V sheet 2x10 ridge 5/8 t&g plywd. 18 R-30 Ins. 4 slab Roof Framing 4x6 header 4x8 header = 3/8 plywd. shearwall w/ 8d at 6 & 12! gyp.bd. 2x12 F.J at 16 o/c 2x8 C.J. 2x8 R.R. Double 2x4 top plates Section Sec. A 2x10 ridge Cal. frame See C
6 GENERAL BUILDING NOTES EFFECTIVE CODE: 2007 CBC 1. Provide smoke detectors as required by CBC Locate in each sleeping room and at a point centrally located in each hall or area giving access to each sleeping area. A minimum of one smoke detector is required on each story. Smoke detector must be hard-wired in new construction w/battery back up and audible in all sleeping areas. May be solely battery operated in existing construction. 2. All bedrooms, dens, libraries, or similar rooms, which can be readily used as a sleeping room, must have an exterior window for emergency egress per CBC This window must have an open-able area of 5.7 square feet with a minimum 20 width and a minimum 24 height. Note that height of this window is 44 above the floor. 3. Any glass within 60 of tub or shower floor must be tempered per CBC (5). 4. Any individual panes of glass over 9 square feet and within 18 of floor shall be tempered per (7). 5. Any glass in doors or in sidelight(s) within 24 of either door edge per CBC (6) or within 40 of any locking mechanism (per West Covina Security Ordinance) shall be fully tempered. 6. All electrical is to be installed per 2007 CEC. 7. Light fixture over tub or shower to be approved for wet use per CEC 410-4(a). 8. Ultra low flush (1.6-gallon max.) toilets and urinals are required. 9. Minimum 30 wide compartment and minimum 24 clearance in front for the water closet are required. 10. Size of shower stall to comply with CPC 411.7, 1024 sq. in. minimum interior and encompassing a 30 circle. 11. Comply with West Covina Security Ordinance. 12. Anchored bolts shall be minimum of 5/8 diameter, 10 6 O.C. starting 12 from corners with 7 embedment in concrete with square washer 2 x 2 x 3/ Ceiling insulation shall be minimum R Wall insulation shall be minimum R Raised floor insulation shall be minimum R Windows shall have U-Value of.75 (Dual Pane Aluminum Frame windows are deemed to meet this U- Value). 17. Any east or west facing windows must have a maximum shading coefficient of.40. To comply; specify on plans white venetian or mini blinds on any east or west facing windows to be installed at final inspection OR specify on plans to install windows labeled by the manufacturer to have a maximum shading coefficient (SC) of.40 (such as dual pane low E windows). 18. No electric space heating or cooling allowed. 19. General lighting in kitchen and in water closet room must be florescent. Additional task lighting may be incandescent and must be switched separately.
1/2" CDX PLY W/ 8d @ 6"/ 6"/ 12" 2x ROOF RAFTERS @ 16"OC W/ R-30 BATT. INSUL. (COMMON NAILS)
TYPE V CONSTRUCTION IS A CLASSIFICATION OF BUILDINGS BY CONSTRUCTION MATERIALS AND METHODS. IT IS THE LEAST RESTRICTIVE PERMITTED BY THE UNIFORM BUILDING CODE AND INCLUDES LIGHT, WOOD-FRAME CONSTRUCTION.
More informationCITY OF BERKELEY BUILDING PERMIT DETAILED CHECKLIST
CITY OF BERKELEY DETAILED CHECKLIST This checklist will assist you in preparing plans for submittal with a building permit application. Alterations, additions and remodeling projects may not require all
More informationBUILDING PERMIT SPECIFICATIONS
BUILDING PERMIT SPECIFICATIONS The below noted requirements are based upon La Plata County Building Code. These specifications are not intended as a complete set of requirements, but are intended to provide
More informationBuilding Information Packet
Code Enforcement Department 882-9225 Building Information Packet The following information has been compiled to help you as a homeowner or contractor with the various steps and requirements for a building
More informationHow To Build A Basement House
Single Family Basement Finish Purpose of Guide The purpose of this guide is to assist you in the permit process for your project. This handout is intended as a basic plan submittal under the 2009 International
More informationSample Drawing Package for One and Two Family Dwelling Applications
Sample Drawing Package for One and Two Family Dwelling Applications For a full list of submission requirements, refer to the relevant checklist for your application found on our website: http://vancouver.ca/home-property-development/application-forms-and-checklists.aspx
More informationBUILDING SAFETY UNIT
POLICY Page 1 of 5 SUBMITTAL REQUIREMENTS FOR ONE AND TWO FAMILY DWELLINGS, ADDITIONS AND RENOVATIONS All submittals shall be site specific and designed to the provisions of the 2012 International Residential
More informationResidential Decks. Planning and Development Services Department
Building Safety Division 8500 Santa Fe Drive Overland Park, KS 66212 (913) 895-6225 Fax (913) 895-5016 Email: permitservices@opkansas.org Planning and Development Services Department Residential Decks
More informationSingle Family Residential Basement Finish
How to Use This Guide Building Guide Pottawattamie County Planning & Development Department Building & Safety Division Single Family Residential Basement Finish Provide two (2) sets of plans and complete
More informationWINDOW AND DOOR REPLACEMENT REQUIREMENTS
WINDOW AND DOOR REPLACEMENT REQUIREMENTS Should you have any questions after reading the following information, please call the Building Inspection Department at 651-439-4439 to discuss the topics of concern.
More informationThis handout is a guide only and does not contain all of the requirements of the Minnesota State Building Code or city ordinances.
Basement Finishing Guide Community Development Department Building Inspections Division 5200 85 th Avenue North / Brooklyn Park, MN 55443 Phone: (763) 488-6379 / Fax: (763) 493-8171 6/15 www.brooklynpark.org
More informationResidential Building Permits
LANE COUNTY PUBLIC WORKS Residential Building Permits LAND MANAGEMENT DIVISION 3050 N. DELTA HWY, EUGENE OR 97408 i CONTACT PHONE NUMBERS: Building Program: (541) 682-4651 Inspection Requests: (888) 299-2821
More informationResidential Plan Routing Information
Residential Plan Routing Information BUILDING INSPECTIONS 800 4th AVENUE EAST WEST FARGO, ND 58078 PHONE: 701-433-5480 The building Inspection s Department receives and issues all applications for building
More informationSTANDARD OPEN PATIO COVER
STANDARD OPEN PATIO COVER BUILDING & SAFETY DIVISION 201 E. LA HABRA BLVD. LA HABRA, CA 90631 62-90-9710 Call Before You Dig 1-800-227-2600 PLEASE NOTE: This information Bulletin is made available to assist
More informationCustom 30 x 20-8 Garage Plan Plan #g233 By SDS-CAD Specialized Design Systems
P O Box 34 Mendon, Utah Custom 30 x 20-8 Garage Plan Plan #g233 By Page 1 Title Page Page 2 Main Floor Plan Page 3 Foundation Plan Page 4 Elevation Views Page 5 Framing and Details Page 6 Typical Section
More informationThe Lambton County Homeowner's BUILDING PERMIT INFORMATION GUIDE
The Lambton County Homeowner's BUILDING PERMIT INFORMATION GUIDE BUILDING SERVICES DEPARTMENT 789 Broadway Street, Box 3000 Wyoming, ON N0N 1T0 Telephone: 519 845-0801 Toll-free: 1-866-324-6912 Fax: 519
More informationINFORMATION BULLETIN NO.
Requirements for Plans Review Submittal, One- and Two-Family Dwellings INFORMATION BULLETIN NO. 100 (June 26, 1998, Revised March 26, 2009) City Planning & Development - Development Services City of Kansas
More informationDevelopment Services City of Lawrence, KS
Development Services City of Lawrence, KS Building Planning Table R301.2 (1) Climatic & Geographic Design Criteria Building Planning The design criteria for wind speed increased from 90 MPH to 115 MPH.
More informationREQUIREMENTS FOR SUBMITTING PLANS FOR NEW CONSTRUCTION
RESIDENTIAL: REQUIREMENTS FOR SUBMITTING PLANS FOR NEW CONSTRUCTION 2 COMPLETE SETS OF PRINTS WITH ENGINEERS STAMP ON FOUNDATION PLAN INCLUDING ELECTRICAL, PLUMBING, ETC. SITE PLAN SHOWING HOUSE LOCATION
More informationAttached/Detached Patio Cover/Carport
CITY OF MANTECA COMMUNITY DEVELOPMENT DEPARTMENT 1001 West Center Street Manteca, CA 95337 FAX (209) 923-8955 Building Safety Division (209) 456-8550 Community Development/Planning Division (209) 456-8500
More informationThe replacement or modification of existing windows shall comply with the following requirements:
City of La Habra Heights Building Division 1245 N. Hacienda Road La Habra Heights, CA 90631 Office: (562) 694-6302 ext. 228 Fax: (562) 690-5010 WINDOW REPLACEMENT 2010 CALIFORNIA RESIDENTIAL CODE (CRC)
More informationDevelopment Services Department Building Permit & Inspection Services Shed and Garage Construction Guide for Detached and Semi-Detached Dwellings
Development Services Department Building Permit & Inspection Services Shed and Garage Construction Guide for Detached and Semi-Detached Dwellings H:/forms/handouts/bldg071.docx Shed and Garage Construction
More informationINFORMATION BULLETIN NO.
Requirements for Plans Review Submittal, One- and Two-Family Dwellings INFORMATION BULLETIN NO. 100 June 26, 1998 (Revised June 4, 2014) City Planning & Development - Development Services City of Kansas
More informationFooting and Temporary Power Inspection
Footing and Temporary Power Inspection Address: Date: Permit #: Inspector: # General Code Sec. OK C* Number, Location and Remarks 1 Permit posted on site Local 2 Port-o-let Local 3 Setbacks - front, sides,
More information4. ANCHOR BOLTS AND STRAPS a. ½" anchor bolts shall be embedded 7" into concrete a maximum of 6' on center and 12" from corners and ends of plates.
GENERAL CODE REQUIREMENTS (BASEMENTS) 1. FOOTINGS a. Footings shall be below frost line depth (42"). b. For an 8" foundation wall, footings shall be no less than 8" deep and 16" wide. c. Steel reinforcement
More informationH:\forms\handouts\bldg049 1 of 11 Revised Mar 2/15/dh
Accessory Apartment Construction Guide For Single Detached Dwelling and Semi-Detached Dwellings that have been in existence for at least five (5) years Notes: Buildings that are less than five (5) years
More informationCLIENT. Inspection Report. 271 Front St. Alert Bay, B.C. Island Building Inspections V ANCOUVER I SLAND B. C.
CLIENT Inspection Report 271 Front St. Alert Bay, B.C. Island Building Inspections 2013 V ANCOUVER I SLAND B. C. Elevation Photos For the Property at 271 Front Street Alert Bay, BC ELEVATION PICTURES Front
More informationResidential Deck Safety, Construction, and Repair
Juneau Permit Center, 4 th Floor Marine View Center, (907)586-0770 This handout is designed to help you build your deck to comply with the 2006 International Residential Building code as modified by the
More informationCOMMERCIAL PLAN SUBMISSION FOR NEW CONSTRUCTION AND/OR RENOVATIONS
COMMERCIAL PLAN SUBMISSION FOR NEW CONSTRUCTION AND/OR RENOVATIONS Permit applicants shall submit three (3) COMPLETE SETS of plans and specifications with each application for a permit. Plans and specifications
More informationEstimated Cost of Repair
1 Applicant: Property: Home: Business: Assessor: Applicant Number: Type of Loss: Hurricane Date Contacted: 1/18/2014 Date of Loss: 10/29/2012 Date Received: 1/14/2014 Date Inspected: 2/4/2014 Date Entered:
More informationSingle Family Residential Building Permit Questions & Answers
Single Family Residential Building Permit Questions & Answers Prepared by Dept. of Public Works Revised 07/01/13 200 East Park Street Edwardsville, IL 62025 (618) 692-7535 (618) 692-7505(Fax) Hours: Monday
More informationCity of St. Charles Basement Finish or Remodel
City of St. Charles Basement Finish or Remodel Building & Code Enforcement Division 2 East Main Street St. Charles IL 60174 630.377.4406 (Office) 630.443.4638 (Fax) http://www.stcharlesil.gov Please direct
More informationResidential Building Permit Process
Residential Building Permit Process Planning and Economic Development Department Development Services Division INTRODUCTION The City of Tulsa is committed to economic development and to being a helpful
More informationMark Cramer Inspection Services, Inc.
Mark Cramer Inspection Services, Inc. 492 Twentieth Avenue, Indian Rocks Beach, FL 34635-2970 (727) 595-4211 Fax (727) 596-7583 Certified Member #12085 American Society of Home Inspectors Construction
More informationRESIDENTIAL WINDOW REPLACEMENT
3S258 MANNING AVENUE WARRENVILLE, IL 60555 PH: 630.393.9050 FAX 630.393.1531 RESIDENTIAL WINDOW REPLACEMENT A building permit is required for the installation or replacement of windows in a residence.
More informationGENERAL BUILDING PERMIT INFORMATION FOR: RESIDENTIAL ALTERATIONS & ADDITIONS
GENERAL BUILDING PERMIT INFORMATION FOR: RESIDENTIAL ALTERATIONS & ADDITIONS INFORMATION GUIDELINE 1 Jan, 2014 CITY OF ESCONDIDO BUILDING DIVISION 201 N. BROADWAY, ESCONDIDO, CA 92025 (760) 839-4647 GENERAL
More informationPage 1 of 6 COMPLIANCE CHECKLIST. > Long Term Care Facility - Nursing Unit
COMPLIANCE CHECKLIST Page 1 of 6 > Long Term Care Facility - Nursing Unit The following checklist is for plan review of new long-term care facilities and new additions to existing long-term care facilities.
More informationESSENTIAL CURRICULUM ARCHITECTURAL DESIGN ACADEMY
ESSENTIAL CURRICULUM ARCHITECTURAL DESIGN ACADEMY HOWARD COUNTY MARYLAND ARCHITECTURAL DESIGN ACADEMY Architectural Design 1 Introduction / Overview of Course This course will introduce the basic principles
More informationCITY OF YORBA LINDA P.O. BOX 87014 CALIFORNIA 92885-8714
CITY OF YORBA LINDA P.O. BOX 87014 CALIFORNIA 92885-8714 BUILDING DIVISION (714) 961-7120 Single Family Residential New Construction, Additions & Alterations Submittal Requirements Required agency approvals
More informationSuperform Products Ltd.
TYPICAL CORNER REINFORCING NOTE : SEE ENGINEERED REBAR SCHEDULES SUPPLIED BY THE MANUFACTURER STEEL REINFORCEMENT WALL CORNER 90 Copyright 2012 Sept. 2012 5.1.1 Rebar Spacing 6" 12" Max. Load LB./FT. 2000
More informationAdult Family Home (AFH) LOCAL BUILDING INSPECTION CHECKLIST Code References: 2012 IRC Section R325 (WAC 51-51) APPLICATION NUMBER:
Adult Family Home (AFH) LOCAL BUILDING INSPECTION CHECKLIST Code References: 2012 IRC Section R325 (WAC 51-51) APPLICATION NUMBER: SECTIONS 1, 2, 3, AND 4 MUST BE COMPLETED BY APPLICANT BEFORE INSPECTION
More informationPre-Drywall Inspection Report
SM MEDALLION INSPECTIONS helping people make informed decisions Pre-Drywall Inspection Report 5657 Garden Valley Place Milton, Georgia 30024 Prepared for Betsy and Paul Dougherty January12, 2015 Medallion
More informationPage & Turnbull imagining change in historic environments through design, research, and technology
DCI+SDE STRUCTURAL EVALUATIONS OFFICE BUILDING, TOOL SHED & WATER TANK, AND BLACKSMITH & MACHINE SHOP BUILDINGS SAN FRANCISCO, CALIFORNIA [14290] PRIMARY PROJECT CONTACT: H. Ruth Todd, FAIA, AICP, LEED
More informationHow To Make A House Safe
1 RESIDENTIAL Screen Enclosures Orange County Residential Code Compliance Alternative design method for screen enclosures R301.2.1.1.3 PLAN REVIEW Engineered plans must state that the Alternative Design
More informationSelf-Home Inspection Checklist
To be used as a first home visit for note taking. Visit www.homeinspectiondirect.com for more tips and information about buying a home and hiring a home inspector. This form in no way replaces a professional
More informationApplications for building permits will not be reviewed until all of the required information has been submitted.
NOTICE: Applications for building permits will not be reviewed until all of the required information has been submitted. Once all items are submitted a minimum of ten (10) working days are required to
More informationCALIFORNIA BUILDING CODE
CALIFORNIA BUILDING CODE NONSTRUCTURAL DESIGN REQUIREMENTS This section contains portions of the California Building Code which relate to basic minimum nonstructural design requirements for a residence.
More informationBOROUGH OF NATIONAL PARK APPLICATION FOR A CERTIFICATE OF OCCUPANCY FOR CHANGE OF OCCUPANCY ADDRESS OF PROPERTY FOR INSPECTION CURRENT OWNER
BOROUGH OF NATIONAL PARK APPLICATION FOR A CERTIFICATE OF OCCUPANCY FOR CHANGE OF OCCUPANCY ADDRESS OF PROPERTY FOR INSPECTION # BLOCK LOT VACANT YES NO CURRENT OWNER NAME ADDRESS TELEPHONE # PROSPECTIVE
More informationCity of Morro Bay Building Division 955 Shasta Ave., Morro Bay, CA 93442-1900, 805-772-6261
City of Morro Bay Building Division 955 Shasta Ave., Morro Bay, CA 93442-1900, 805-772-6261 BUILDING PERMIT APPLICATION Permit No. Type Date Project Address Parcel No. Lot Block Tract Project Description:
More informationCITY OF FAIRFAX CODE ADMINISTRATION 703-385-7830 / FAX 703-385-9265 www.fairfaxva.gov
CITY OF FAIRFAX CODE ADMINISTRATION 703-385-7830 / FAX 703-385-9265 www.fairfaxva.gov Finishing a basement to make additional living space in a house is a popular construction project for many homeowners.
More informationResidential Building Inspection Policies
CONCRETE 1. A footing inspection has been called in, but a monolithic slab shows on the plans. Cancel the footing and create a slab inspection, as long as there is a Passed Plumbing Rough (05). 2. A stemwall
More informationCertification: Building Plans Examiner. Exam ID: B3
Certification: Building Plans Examiner Exam ID: B3 Scope: A Building Plans Examiner will be responsible for reviewing submitted plans to determine if they meet the requirements of the various Building
More informationBasic Requirements for Residential Plan Review _
Basic Requirements for Residential Plan Review _ Below you will find the basic requirements for your plan submittal. General: Drawn to scale Plan Size minimum: 9 x 12 Designer, Engineer, or Architect name,
More informationPatio Covers / Carports
Patio Covers / Carports Building Guides for Homeowners Why Do I need a Permit? D I D Y O U K N O W? As owner-builder you are the responsible party of record on such a permit. If your work is being performed
More informationPOST AND FRAME STRUCTURES (Pole Barns)
POST AND FRAME STRUCTURES (Pole Barns) Post and frame structures. The following requirements serve as minimum standards for post and frame structures within all of the following structural limitations:
More informationGROWTH MANAGEMENT DEPARTMENT 201 SE 3 rd ST, (Second Floor), Ocala, FL 34471 (352) 629-8421; FAX: (352) 629-8264
BUILDING CODE GUIDELINES FOR ELECTRICAL INSPECTIONS Building Code compliance is the obligation of design professionals and/or contractors. Plan Review and Inspection Guidelines are intended to be used
More information2. What building projects are exempted? (permit not required)
BUILDING AND SAFETY DEPARTMENT 1. What building projects require a permit? Following is a list of projects that require building permits based on Appendix chapter 1 of the California Building Code and
More informationKITCHEN AND BATH REMODELING BUILDING PERMIT REQUIREMENTS
St. Louis County Department of Public Works Division of Code Enforcement KITCHEN AND BATH REMODELING BUILDING PERMIT REQUIREMENTS This guideline is intended to provide the homeowner/contractor with the
More information1. Concrete: T W L / 27 = Concrete C.Y. Multiply Feet Thickness x Feet Width x Feet Length / 27 = Cubic Yards.
Formulas: Formula Letters: H= Height BCY = Bank Cubic Yards L= Length CCY = Compact Cubic Yards P= Perimeter LCY = Loose Cubic Yards LF = Linear Feet or Lineal Feet BF = Board Foot or Feet SF = Square
More informationPreparation for 2015 Residential Code Changes Discussion with Local Builders and Designers
City of Duluth Preparation for 2015 Residential Code Changes Discussion with Local Builders and Designers Thank you for taking the time to join us today. We know you are busy and your time is valuable.
More informationGENERAL ELECTRICAL REQUIREMENTS
GENERAL ELECTRICAL REQUIREMENTS RECEPTACLE SPACING Within 6-feet of the edge of any door HABITABLE Not more than 12-feet apart along wall ROOMS: At all wall spaces 24 or more wide Within 24 of edge of
More informationBureau Veritas Contact Information
Bureau Veritas Contact Information Permit Submittal The permit documents and fees will be submitted to the city. Submittal documents should be complete to expedite plan review and permit issuance. Please
More informationTypical Finished Basement Details
Fauquier County, Virginia Typical Finished Basement Details Based on the 2012 International Residential Code Finished basements must be constructed in conformance with this document. For requirements,
More informationDoes Wall Township require an inspection by the building department on resale of a home?
Selling your home Does Wall Township require an inspection by the building department on resale of a home? No. We do not require a Certificate of Continued Occupancy on the resale of home. A Smoke Detector,
More informationUpper Southampton Township Department of Licenses and Inspections 939 Street Rd. Southampton, Pa. 18966 Phone: 215-322-9700 Fax: 215-322-5842
Upper Southampton Township Department of Licenses and Inspections 939 Street Rd. Southampton, Pa. 18966 Phone: 215-322-9700 Fax: 215-322-5842 APPLICATION for ZONING and BUILDING PERMIT APPLICATION INSTRUCTIONS:
More informationRESIDENTIAL WOOD DECKS
RESIDENTIAL WOOD DECKS 1 A Building Permit is required for the construction of a wood deck where the deck is more than 600 mm above grade at any point. Definition: For the purposes of this pamphlet, a
More informationUncovered Decks & Porches
Uncovered Decks & Porches Building Guides for Homeowners Why Do I need a Permit? D I D Y O U K N O W? As owner-builder you are the responsible party of record on such a permit. If your work is being performed
More informationHomeSpec REPORT SUMMARY
HomeSpec 04/25/2007 Ms. Rachel Trujeque Re: 13038 West Plum Road Lot #1225 - Peoria, AZ. 85383 - Pre Drywall Inspection Dear Ms. Trujeque, At your request, a visual pre drywall inspection of the above
More informationHEDDERMAN ENGINEERING, INC. www.heddermanengineering.com Office 281-355-9911, Fax 281-355-9903 office@heddermanengineering.com
HEDDERMAN ENGINEERING, INC. www.heddermanengineering.com Office 281-355-9911, Fax 281-355-9903 office@heddermanengineering.com, 2011 TO: Mr. REF: CONDITION OF PROPERTY SURVEY Dear Mr. : At your request,
More informationFinal inspections are completed by site visit only. Access to fenced yards shall be planned.
ROOFING RESIDENTIAL BUILDING INSPECTIONS DEPARTMENT www.ci.blaine.mn.us This handout is intended only as a guide and is based in part on the 2015 Minnesota State Building Code, Blaine City ordinances,
More informationPhysical Address/Intersection: Name of Project: Within a NFIP 100/500yr Floodzone:
Choctaw Date Recorded: Permit # RESIDENTIAL - BUILDING Permit APPLICATION Physical Address/Intersection: Name of Project: Within a NFIP 100/500yr Floodzone: YES NO Sec., Township, Range/Subdivision: Acres/Block:
More informationNew Home Construction Packet
New Home Construction Packet Congratulations! You are building a new home in Meyerland. This packet of information was assembled to assist you with the process. It contains all the forms that you will
More informationAdditions and Alterations
Additions and Alterations Addition and alteration construction is a miscellaneous grouping of home improvement and renovation projects that are generally geared toward the enhancement of an existing principal
More informationKatharine Teats House HABS No. CA-2162 3560 Seventh Avenue San Diego San Diego County /J/Vf# <? California /WtO
Katharine Teats House 3560 Seventh Avenue San Diego San Diego County /J/Vf#
More informationResidential Building Permits Information
City of Bonham Building Department 514 Chestnut St. Bonham, Texas 75418 OFFICE: (903) 583-7555 FAX: (903)583-5761 Residential Building Permits Information Application for Permits: To apply for a permit,
More informationBuilding Code Clarifications - 7. Fire Resistance
Building Code Clarifications - 7. Fire Resistance 7.1 (15-12-030) Use of combustibles in Type III construction roof assemblies Code Section (15-12-030) Use of Combustibles was revised on May 17, 2000,
More information2012 Ontario Building Code Requirements for New Construction. Bradford West Gwillimbury Building Division March 5, 2012
2012 Ontario Building Code Requirements for New Construction Bradford West Gwillimbury Building Division March 5, 2012 1 Ontario Building Code changes Applicable to permits applied for after December 31,
More informationCOMMONLY USED RESIDENTIAL BUILDING CODES
COMMONLY USED RESIDENTIAL BUILDING CODES INTERNATIONAL RESIDENTIAL CODE (2009) form revised 5/10 FOUNDATION 1. DESIGN OF FORMWORK. Section 1906.1 IBC 2009, Section R404.1.2.3.6 IRC 2009, ACI 318 Section
More informationTYPICAL PATIO COVERS 111
City of Laguna Niguel Building Division 30111 Crown Valley Pkwy Laguna Niguel, CA 92677 (949) 362-4360 FAX 362-4369 www.cityoflagunaniguel.org TYPICAL PATIO COVERS 111 PLEASE NOTE: This information Bulletin
More informationSite Development Information Worksheet for single family residential development
Site Development Information Worksheet for single family residential development Project description: Address: Owner Name: Phone No. Date Signature & phone number of Individual who Completed this Worksheet
More informationOntario s 2012 Building Code Division B, Part 9 (Ontario Regulation 332/12)
Ontario s 2012 Building Code Division B, Part 9 (Ontario Regulation 332/12) Notice: This e-learning module is intended for general information purposes only. It only highlights certain provisions of the
More informationHolz Choices & Specifications
March 21, 2011 0. SALES AND DESIGN 1. UTILITIES AND PERMITS Holz Choices & Specifications 2. EXCAVATION AND LOT PREPARATION Job Beginning date of Monday May 2 nd, 2011 ALTERNATE: Garage walls as drawn
More informationTypical Finished Basement Details
Fairfax County, Virginia Typical Finished Basement Details Based on the 2012 International Residential Code Finished basements must be constructed in conformance with this document. For requirements, details
More informationChapter 3 Pre-Installation, Foundations and Piers
Chapter 3 Pre-Installation, Foundations and Piers 3-1 Pre-Installation Establishes the minimum requirements for the siting, design, materials, access, and installation of manufactured dwellings, accessory
More informationSt. Louis County Department of Public Works Division of Code Enforcement. When is a Building Permit required for Residential Projects?
St. Louis County Department of Public Works Division of Code Enforcement When is a Building Permit required for Residential Projects? BUILDING CONSTRUCTION WORK A Building Permit is required to construct,
More informationVILLAGE OF HUDSON FALLS 220 MAIN STREET HUDSON FALLS, NY 12839 (518) 747-5426 /
John E. Barton Mayor Ellen M. Brayman Clerk/Treasurer VILLAGE OF HUDSON FALLS 220 MAIN STREET HUDSON FALLS, NY 12839 (518) 747-5426 / Trustees: James Gallagher Robert Cook Michael Horrigan Thomas VanAernem
More informationNumber of Sides Required to Have a Handrail
Excerpt from 2012 B.C. Building Code HANDRAILS & GUARDS 9.8.7. Handrails 9.8.7.1. Required Handrails 1) Except as provided in Sentences (2) to (4), handrails shall be installed on stairs and ramps in accordance
More informationHow To Repair A House
Assessing Structural Damages Please note-this presentation is only intended to be used as a basic educational tool and is by no means all encompassing. Each property should be treated on a case by case
More informationGuidelines for Earthquake Bracing Residential Water Heaters
Guidelines for Earthquake Bracing Residential Water Heaters Department of General Services Division of the State Architect In accordance with the Health and Safety Code Section 19215, the Division of the
More informationFree 12 x 8 Shed Plan With Illustrations, Blueprints & Step By Step Details
Free 12 x 8 Shed Plan With Illustrations, Blueprints & Step By Step Details Brought To You By: MyShedPlans Click Here To Download 12,000 Shed Plans >> 12 x 8 Basic Shed This 8 12-ft. shed features a simple
More informationThe UPLANDS at ORO VALLEY Sterling Features
The UPLANDS at ORO VALLEY Sterling Features STERLING FEATURES Enhanced Air Quality System 2x6 Exterior Walls in Living Area Engineered Post Tension Concrete Slab Dual Pane Low-E Windows Covered Patio Gated
More informationWOODLAND HOMES BUILDING PROCESS A STEP BY STEP CONSTRUCTION GUIDE TO YOUR NEW HOME
WOODLAND HOMES BUILDING PROCESS A STEP BY STEP CONSTRUCTION GUIDE TO YOUR NEW HOME 1 THE BUILDING PROCESS The focus of Woodland Homes building department is Quality, Service and Predictability. Through
More informationPDmB, Inc. Definitions
Page 1 of 11 Definitions S Satisfactory Meets industry standards for proper material and installation NP Not Present Condition or item was not present at time of inspection NI Not Inspected Condition or
More informationBUILDING DEPARTMENT 8748 W. 82 nd Place - Justice, IL 60458 Phone: (708) 458-2130 Fax: (708) 458-3207
BUILDING DEPARTMENT 8748 W. 82 nd Place - Justice, IL 60458 Phone: (708) 458-2130 Fax: (708) 458-3207 SELF EVALUATION CHECKLIST FOR RESIDENTIAL AND MULTI-FAMILY DWELLING INSPECTIONS The attached checklist
More informationBuilding Permit Application Packet. BUILDING CODES Adopted by La Plata County For Enforcement In The Unincorporated Areas Of La Plata County
Building Permit Application Packet The purpose of Building Codes is to establish the minimum requirements to safe guard the public health, safety and general welfare through structural strength, means
More informationThis handout is a guide only and does not contain all of the requirements of the Minnesota State Building Code or city ordinances.
Residential Decks Community Development Department Building Inspections Division 5200 85 th Avenue North / Brooklyn Park, MN 55443 Phone: (763) 488-6379 / Fax: (763) 493-8171 6/15 www.brooklynpark.org
More informationBuilding Condition Assessment Report
C2 - Nurses Resident (aka Administration) Building Condition Assessment Report Asset Address Address Construction Year Size (Gross Floor Area) Asset Type Floors Above Ground Inspection Date C2 - Nurses
More informationFig. 2 WALL-TO-WALL PANEL CONNECTIONS CORNER WALL CONNECTION
SIPS SCREWS WITH MINIMUM 1" PENETRATION IN WOOD MEMBER IN SIP WALL PANEL CONNECTED TO @ 24" O.C. MAXIMUM OUTSIDE SKIN EACH SIDE OF FRAMING TYP. AS RECOMMENDED BY FOAM CORE AS EACH SIDE OF FRAMING TYP.
More informationResidential Adjustments. Overview 4.1
Overview 4.1 Summary This chapter contains an overview of residential structural components, quality of construction, main dwellings, and construction types. It also provides adjustments such as wall height,
More informationC I T Y O F P E A R S A L L
The Largest City Between San Antonio and Laredo COMMUNITY DEVELOPMENT C I T Y O F P E A R S A L L A Business-Friendly, Family-Oriented Community Building Department Application Information (Please read
More information