PORTABLE OUTLET BOXES PORTABLE OUTLET BOXES. MULTIPLE OUTLET BOXES 3000 Series

Size: px
Start display at page:

Download "PORTABLE OUTLET BOXES PORTABLE OUTLET BOXES. MULTIPLE OUTLET BOXES 3000 Series"

Transcription

1 MULTIPLE OUTLET BOXES 3000 Series Woodhead s Super-Safeway duplex and outlet boxes are listed for portable usage and provide the safety and reliability required on today s job sites. Made of durable NEoTEX - rubber to withstand the impact of drops, bumps, and other damage consistent with industrial use, these boxes provide the peace of mind that their exterior will not become energized by loose wire contacts, unlike common metal junction boxes. Standard depth 3-3/8" and extended depth 4-3/8" boxes accommodate multiple receptacle types with various degrees of weather protection. Choose pre-wired Woodhead solutions or make your own portable power outlet box. Spring-loaded flip lid boxes feature MAX-LOC cord grips while standard outlet boxes come with a screw-tight cord clamp. Super-Safeway Standard Depth Outlet Box (3-3/8") with two duplex or two s WITH PLUG AND TWO DUPLEX OUTLET BOX TWO SINGLE OUTLET BOX CONFIGURATION 4/3 AWG CORD STANDARD WITH FLIP LIDS (F2) STANDARD WITH FLIP LIDS (F2) NEMA _ _43 NEMA /3 AWG _23 NEMA L _ _42 NEMA L _ _ _ _43 NON-NEMA _ _43 WITH COVERPLATE ONLY " DIAMETER " DIAMETER CORD DIAMETER RANGES " " " " Super-Safeway Extended Depth Outlet Box (4-3/8") with two duplex or two s WITH PLUG AND TWO DUPLEX OUTLET BOX TWO SINGLE OUTLET BOX CONFIGURATION 2/3 SOW CORD STANDARD WITH FLIP LIDS (F3) STANDARD WITH FLIP LIDS (F3) NEMA NEMA _ _23 NEMA L NEMA L NEMA L _ _22 NEMA L _ _23 NON-NEMA _ _23 WITH COVERPLATE ONLY " DIAMETER " DIAMETER CORD DIAMETER RANGES " " " " NOTE: FOR UV RESISTANT BOXES, ADD SUFFIX BLK TO NUMBER. FOR PROTECTION: ADD PLG SUFFIX FOR THE ADDITION OF 5A, 20V, PLUG. ADD IN SUFFIX FOR THE ADDITION OF 5-20A, 20/240V INLINE. FOR COMPONENT PARTS AND ACCESSORY INFO, SEE PAGE 44. FOR WIRE MESH GRIPS, SEE PAGES 6 & 209. Primary Cord Length: Use the following chart to specify the length of the primary cord E 23 CORD LENGTH ' E 25' A 50' B 00' D Feed-through boxes are a convenient way to string power to multiple points. MULTIPLE OUTLET BOXES 3000 Series Super-Safeway Standard Depth Feed-Thru Outlet Box (3-3/8") With F2 cord grip. Available with two duplex or two s TWO DUPLEX OUTLET BOXES TWO SINGLE OUTLET BOXES CONFIGURATION STANDARD WITH FLIP LIDS STANDARD WITH FLIP LIDS NEMA F- WITH COVERPLATE ONLY 3000F 3005F.39" DIAMETER 300F 3006F.56" DIAMETER 3003F 3008F CORD DIAMETER RANGES " " " " Super Safeway Extended Depth Feed-Thru Outlet Box (4-3/8") With F3 cord grip. Available with two duplex or two s TWO DUPLEX OUTLET BOXES TWO SINGLE OUTLET BOXES CONFIGURATION STANDARD WITH FLIP LIDS STANDARD WITH FLIP LIDS NEMA F- WITH COVERPLATE ONLY 3080F 3085F.39" DIAMETER 308F 3086F.56" DIAMETER 3083F 3088F CORD DIAMETER RANGES " " " " NOTE: FOR COMPONENT PARTS AND ACCESSORY INFO, PLEASE SEE PAGE 44. FOR WIRE MESH GRIPS, SEE PAGES 6 & 209. FOR UV RESISTANT, ADD SUFFIX BLK TO PART NUMBER. 40 WOODHEAD CALL US TODAY! WOODHEAD 4

2 MULTIPLE OUTLET BOXES 3000 Series Replacement Parts OUTLET BOX DEPTH SCREW CLAMP GRIP ONE MAX-LOC GRIP TWO MAX-LOC GRIPS STANDARD 3-3/8" (F2) 3050F (F2) EXTENDED 4-3/8" (F3) 3090F (F3) EXTENDED 4-3/8" 309 (F4) 309F (F4) Coverplates for Standard MULTIPLE OUTLET BOXES Pendant Drops U.L. listed, CSA certified for damp or wet locations. Local protection for worksites where permanent outlets are not available. Two Watertite single or duplex receptacles are mounted on a durable corrosion-resistant NEoTEX - rubber enclosure with spring-loaded flip lid covers. Meets the requirements of NEMA Type 4X when properly mated with a Woodhead Watertite plug. MAX-LOC cord grip (F3), and wire mesh cord grip are standard. Available in 5A and 20A straight-blade or locking configurations. Pre-wired Pendant with Two Duplex Receptacles and Flip Lids CONFIGURATION CORD TYPE CORD LENGTH PART NO. NEMA 5-5 4/3 SOOW 6' 70W47L43 5' 70W47M43 25' 70W47A43 NEMA L5-5 4/3 SOOW 6' 75W47L43 5' 75W47M43 25' 75W47A43 NEMA /3 SOOW 6' 70W33L23 5' 70W33M23 25' 70W33A23 Pre-wired Pendant with Two Watertite Single Receptacles and Flip Lids duplex receptacle part no " opening part no part no part no CONFIGURATION CORD TYPE CORD LENGTH PART NO. NEMA L5-20 2/3 SOW 6' 77W47L23 5' 77W47M23 25' 77W47A23 Coverplates for Weather-Resistant duplex receptacle with flip lids part no " opening with flip lids part no with flip lids part no duplex single FS/FD Outlet Box Coverplates for FS/FD with flip lids part no. 306 blank coverplate part no clear silicone Watertite part no MOST WOODHEAD PRODUCTS HAVE U.L. AND/OR CSA APPROVALS. FOR A LISTING OF APPROVALS BY PART NUMBER, SEE PAGES DESCRIPTION STANDARD FEED-THRU 4-/4" DEPTH DESCRIPTION CLEAR SILICONE WATERTITE COVERPLATE WITH 20A/25V DUPLEX WATERTITE COVERPLATE SINGLE WATERTITE COVERPLATE PART NO. 3362GF 60W47DPLX 60W47 42 WOODHEAD CALL US TODAY! WOODHEAD WOODHEAD 43

3 MULTIPLE OUTLET BOXES 3200 Series Woodhead s Super-Safeway heavy duty duplex and outlet boxes are listed for portable usage and provide the safety and reliability required on today s job sites. Made of durable NEoTEX - rubber to withstand the impact of drops, bumps, and other damage consistent with industrial use, these boxes provide the peace of mind that their exterior will not become energized by loose wire contacts, unlike common metal junction boxes. These boxes accommodate one or two s or two duplex receptacles per side (receptacles not included). Boxes (F3 Fittings) MULTIPLE OUTLET BOXES 3200 Series Replacement Parts part no part no Grommets F3 CORD PART DIAMETER COLOR NO " ORANGE " GRAY " " " GRAY " " ORANGE " YELLOW Coverplates for Standard Coverplates for Weather-Resistant FOR RECEPTACLES SEE WIRING DEVICE SECTION PAGES Industrial Grade Heavy-Duty Outlet Box HOLE BOX WITH COVERPLATE ACCEPTS: DIAMETER BOX FLIP LIDS (2) DUPLEX RECEPTACLES () 20A SINGLE LOCKING RECEPTACLE.562" () 30A SINGLE LOCKING RECEPTACLE.78" (2) 20A SINGLE LOCKING RECEPTACLES.562" (2) 30A SINGLE LOCKING RECEPTACLES.78" (2) BLANK COVERPLATES 3200 part no part no. 326 part no. 3260W part no. 326W part no " opening part no part no. 3262W.72" opening part no. 3263W Watertite Heavy-Duty Outlet Box Box with metal-reinforced molded rubber coverplates accommodating two outlets in each plate (four outlets total) in several configurations (receptacles included). Woodhead Watertite outlets are designed with a soft rubber molded lip to form a weather resistant seal when used with a Watertite plug. Rubber closure caps seal outlets when not in use. CONFIGURATION BOX ONLY BOX WITH 25' 2/3 SOW CORD NON-NEMA 32W07 NEMA W33 32W33A23 NEMA W47 32W47A23 NON-NEMA LOCKING 35W07 NEMA L7-5 35W34 NEMA L5-5 35W47 35W47A23 3 POLE, 3 WIRE CROWFOOT 0A 250V / 5A 25V" part no " opening part no Coverplate for Watertite part no FOR USE WITH NON-NEMA NEMA 5-5 NEMA 5-20 NON-NEMA NEMA L7-5 NEMA L5-5 part no. 3264W.72" opening part no WOODHEAD CALL US TODAY! WOODHEAD WOODHEAD WOODHEAD 45

4 MULTIPLE OUTLET BOXES Angled Factory assembled, pre-wired angled outlet box features a molded NEoTEX - rubber housing and non-metallic coverplates as well as a rugged Super-Safeway plug and 2/3 SOW cable. They also are available with weather-resistant spring-loaded flip lid covers. The natural angle design of the box provides arc of bend relief for cords that are powered by this box. The primary plugs for pre-wired boxes match the configuration of the receptacles. Angled RECEPTACLE LOCKING STANDARD STANDARD BOX WITH FEED-THRU FEED-THRU BOX WITH CONFIGURATION TYPE BLADE BOX FLIP LIDS AND PLUG BOX FLIP LIDS AND PLUG NEMA 5-5 TWO DUPLEX 3330_ R_ F_ RF_23 NEMA L5-5 TWO DUPLEX 333_23 333R_23 333F_23 333RF_23 NEMA 5-20 TWO DUPLEX 3332_ R_ F_ RF_23 NEMA L5-20 TWO SINGLE 3333_ R_ F_ RF_23 Primary Cord Length: Use the following chart to specify the length of the primary cord E 23 FACTORY-WI 3-PHASE STRINGER SETS (cntd.) Wiring Schematics: PHASE "C" PHASE "B" PHASE "A" RECEPTACLE RECEPTACLE RECEPTACLE RECEPTACLE RECEPTACLE RECEPTACLE PHASE C/A PHASE B/C RECEPTACLES RECEPTACLES RECEPTACLES (HOT) (Z) (HOT) (HOT) (NEUTRAL) (GROUND) and / , and CORD LENGTH ' E 6' L 25' A 50' B (H) (N) (H) (N) (HOT) (HOT) (Z) (HOT) (NEUTRAL) (GROUND) FACTORY-WI 3-PHASE STRINGER SETS Factory pre-wired portable outlet boxes and cords distribute power safely and easily. Each stringer set contains three 20A 2-pole, 3-wire portable duplex outlet boxes on 0 ft. centers. 30 ft. of 2/5 or 2/4 SOW cable per unit. Weather-resistant NEoTEX - rubber enclosures. Super-Safeway plugs and MAX-LOC nylon cord sealing grips. Available in high-visibility yellow or a low profile black. RECEPTACLES RECEPTACLES RECEPTACLES and /3095-0, and Portable Outlet Box Cordsets RUBBER POLYCARBONATE PHASE PHASE PHASE SOW BOXES BOXES PLUG BOX BOX 2 BOX 3 CABLE NONE A B C 2/ NONE A/B B/C C/A 2/ L2-20 A B C 2/ L2-20 A/B B/C C/A 2/ NONE A/B A/B A/B 2/4 N/A L4-20 A/B A/B A/B 2/4 N/A NON-NEMA A B C 2/5 N/A NON-NEMA A/B B/C A/C 2/5 NOTE: FOR BOXES, ADD BLK SUFFIX TO PART NUMBER. MOST WOODHEAD PRODUCTS HAVE U.L. AND/OR CSA APPROVALS. FOR A LISTING OF APPROVALS BY PART NUMBER, SEE PAGES RECEPTACLE RECEPTACLE RECEPTACLE RECEPTACLE RECEPTACLE RECEPTACLE (HOT) (HOT) (NEUTRAL) (GROUND) / , WOODHEAD CALL US TODAY! WOODHEAD 47

5 MULTIPLE OUTLET BOXES Illuminated Shatterproof Teflon globe mounted on heavy-duty NEoTEX - rubber box containing four single or four duplex receptacles. Standard duplex receptacles protected by spring-loaded flip lid covers; Watertite s protected by rubber closure caps. MAX-LOC F3 cord grip with mesh grip included. Cord diameter range ". Meets NFPA 90 requirements. Black NEoTEX - rubber boxes with unbreakable vinyl coated faceplate. Available with fuses; circuit breakers (NRTL/C); flip lid covers; industrial grade duplex receptacles; MAX-LOC (F4) cord type grips ( in. NPT, weather resistant, cord diameter range "); Motorbase inputs or outputs; and an assortment of NEMA configurations. Products are suitable for heavy industrial/contractor use, film, T.V. and stage production. MULTIPLE OUTLET BOXES 3400 Series Standard Box with MAX-LOC Input Connector (4) DUPLEX RECEPTACLES, PHASE NEMA 5-5 NONE L 340L 3420L NEMA 5-20 NONE L L L-20 (3) DUPLEX RECEPTACLES, 3 PHASE NEMA 5-5 NONE L 343L 3423L NEMA 5-20 NONE L L L-20 Feed-Thru Box with MAX-LOC Input Connector & Motorbase Receptacle (3) DUPLEX RECEPTACLES, PHASE NEMA 5-5 NEMA F 340F 3420F 3400FL 340FL 3420FL NEMA 5-20 NEMA F F F FL FL FL-20 (3) DUPLEX RECEPTACLES, 3 PHASE NEMA 5-20 NEMA L F F F FL FL FL-20 Illuminated Multiple Outlet Box NEMA DUPLEX WITH FLIP LID SINGLE WITH FLIP LID WATERTITE SINGLE CONFIGURATION W/O CABLE ' 4/3 SOW 50' 4/3 SOW W/O CABLE ' 2/3 SOW 50' 2/3 SOW W/O CABLE ' 4/3 SOW 50' 4/3 SOW E B43 32W90-32W90-E43 32W90-B43 L E B43 32W W90-2E43 32W90-2B43 NON-NEMA E B43 32W W90-8E43 32W90-8B43 LOCKING L E B23 NON-NEMA E B23 LOCKING 2 2 Pole, 3 Wire 5A 25V/0A 250V 2 2 Pole, 3 Wire 20A 250V Standard Box with Motor-Base Inlet (3) DUPLEX RECEPTACLES, PHASE NEMA 5-5 NEMA P 340P 3420P 3400PL 340PL 3420PL NEMA 5-20 NEMA P P P PL PL PL-20 (3) DUPLEX RECEPTACLES, 3 PHASE NEMA 5-20 NEMA L P P P PL PL PL WOODHEAD CALL US TODAY! WOODHEAD WOODHEAD 49

PUSHBUTTON/TEST INSTRUMENTS

PUSHBUTTON/TEST INSTRUMENTS Long standing users of electrical products know the name to count on for dependable and durable electrical specialty products Woodhead. Overhead, underfoot, in hand, everywhere from construction sites,

More information

Cable and Cord Reels. Section R. Cable and Cord Reels Index. Index

Cable and Cord Reels. Section R. Cable and Cord Reels Index. Index Section R Index Product Page Number and R-2 3 Weatherproof Cable and Static Discharge Reels R-4 R-5 R-6 Index www.hubbell-wiring.com and and Hubbell Electric Cord and Cable Reels Hubbell Wiring Device

More information

ELECTRICAL CONTRACTORS THE UNIVERSITY OF TENNESSEE KNOXVILLE, TENNESSEE SECTION 26 27 26, PAGE 1 SECTION 26 27 26 WIRING DEVICES

ELECTRICAL CONTRACTORS THE UNIVERSITY OF TENNESSEE KNOXVILLE, TENNESSEE SECTION 26 27 26, PAGE 1 SECTION 26 27 26 WIRING DEVICES KNOXVILLE, TENNESSEE SECTION 26 27 26, PAGE 1 PART 1 - GENERAL 1.01 DESCRIPTION OF WORK: SECTION 26 27 26 A. The extent of wiring device work is indicated by drawings and schedules. Wiring devices are

More information

BERTHOLD ELECTRIC GENERATOR CONNECTION CABINET

BERTHOLD ELECTRIC GENERATOR CONNECTION CABINET BERTHOLD ELECTRIC GENERATOR CONNECTION CABINET Berthold Electric Company s Generator Connection Cabinet provides a quick and convenient station to connect a portable generator to a facility s main service

More information

READ THIS MANUAL BEFORE PROCEEDING WITH THE INSTALLATION. FAILURE TO FOLLOW THE INSTALLATION INSTRUCTIONS MAY VOID YOUR WARRANTY!

READ THIS MANUAL BEFORE PROCEEDING WITH THE INSTALLATION. FAILURE TO FOLLOW THE INSTALLATION INSTRUCTIONS MAY VOID YOUR WARRANTY! READ THIS MANUAL BEFORE PROCEEDING WITH THE INSTALLATION. FAILURE TO FOLLOW THE INSTALLATION INSTRUCTIONS MAY VOID YOUR WARRANTY! The main power to any existing system must be disconnected prior to the

More information

AdvAntAge SerieS Switch-rAted iec Pin And Sleeve

AdvAntAge SerieS Switch-rAted iec Pin And Sleeve AdvAntAge SerieS Switch-rAted iec Pin And Sleeve now AvAilAble in 30 & 60 AmP Highest Performing IEC Pin and Sleeve Connections for the Most Demanding Environments Hubbell s Pin and Sleeve connections

More information

ELECTRICAL CONNECTORS

ELECTRICAL CONNECTORS ELECTRICAL CONNECTORS 07-09 00-09 04-09 99-09 116 ELECTRICAL CONNECTORS LIGHT POWER MODULES WORKS WITH STANDARD & LED BULBS! WORKS WITH STANDARD & LED BULBS! CALL US TODAY FOR YOUR MODULITE VEHICLE APPLICATION

More information

WHOLESALE DIRECT INC. 5620 WEST 65TH STREET

WHOLESALE DIRECT INC. 5620 WEST 65TH STREET Auto Pump V 200 100 0 100 Max Rating Vehicle mount compressor ensures truck air brake system is properly pressurized for immediate dispatch from station Pressure switch regulated operation automatically

More information

Instruction / Installation Sheet DataComm Electronics 50-6623-WH-KIT Flat Panel TV Cable Organizer Kit with Duplex Power Solution

Instruction / Installation Sheet DataComm Electronics 50-6623-WH-KIT Flat Panel TV Cable Organizer Kit with Duplex Power Solution Instruction / Installation Sheet DataComm Electronics 50-6623-WH-KIT Flat Panel TV Cable Organizer Kit with Duplex Power Solution DataComm Electronics, Inc. 6349 Peachtree Street Norcross, GA 30071-1725

More information

400 Series Buccaneer BUCCANEER POWER. bulgin

400 Series Buccaneer BUCCANEER POWER. bulgin bulgin BUCCANEER FOR POWER Contact Retainer Sealing Gasket O Ring Contacts Locking Ring Retaining Nut Panel Body Contacts Contact Carrier O Ring Main Body Cable Gland Collet Gland Nut Sealed to IP68 when

More information

USA: 866.LAWSON4U (866.529.7664) Canada: 800.563.1717 lawsonproducts.com. Electrical Industrial and Fleet Solutions

USA: 866.LAWSON4U (866.529.7664) Canada: 800.563.1717 lawsonproducts.com. Electrical Industrial and Fleet Solutions USA: 866.LAWSON4U (866.529.7664) Canada: 800.563.1717 lawsonproducts.com Electrical Industrial and Fleet Solutions Lawson's ELECTRICAL SOLUTIONS Electrical Wire Low voltage (60V) and high voltage (300/600V)

More information

Rugged & Reliable Power Connections

Rugged & Reliable Power Connections Rugged & Reliable Power Connections featuring: DECONTACTOR TM Series Switch Rated Plugs & Receptacles High Amperage Plugs & Receptacles Multipin Connectors Benefit from Meltric Plugs, Receptacles, and

More information

Universal MATE-N-LOK Connectors

Universal MATE-N-LOK Connectors Product Facts Pins and sockets can be intermixed in the same housing Positive polarization Rear cavity identification completely enclosed in housings Positive locking housings Insulation capability to.00

More information

PLUGS & RECEPTACLES. INNOVATIVE EXPLOSION PROTECTION by R. STAHL 1-800-782-4357

PLUGS & RECEPTACLES. INNOVATIVE EXPLOSION PROTECTION by R. STAHL 1-800-782-4357 Series Features: Color coding and pin configuration makes it physically impossible to mate plugs and receptacles of different voltages and current ratings (per IEC 60 309-2). Interlocked switch mechanism

More information

HM-W536 Install Guide

HM-W536 Install Guide HM-W536 Install Guide 9/13/2013 IMPORTANT SAFETY INSTRUCTIONS Warning - When using electrical devices, basic safety precautions should be followed to reduce the risk of fire, electrical shock or injury.

More information

Advantages of a Company Switch vs. a Safety Switch Receptacle Combination:

Advantages of a Company Switch vs. a Safety Switch Receptacle Combination: Advantages of a Company Switch vs. a Safety Switch Receptacle Combination: Why a Company Switch Delivers Greater Benefits A Lex Products Corporation Whitepaper. Copyright 2012. Overview: Advantages of

More information

electrics P OW E R E N T RY B A S I C S P OW E R & C O M M U N I C AT I O N S B A S I C S P OW E R D I S T R I B U T I O N B A S I C S

electrics P OW E R E N T RY B A S I C S P OW E R & C O M M U N I C AT I O N S B A S I C S P OW E R D I S T R I B U T I O N B A S I C S P RO D U C T M A P / TA B L E O F C O N T E N T S..................6 8 6 E L E C T R I C S & C O M M U N I C AT I O N S O V E RV I E W.............6 8 9 P OW E R E N T RY B A S I C S PA N E L - M O U N

More information

Common Electrical Hazards in the Workplace Including Arc Flash. Presented by Ken Cohen, PhD, PE & CIH (Ret.)

Common Electrical Hazards in the Workplace Including Arc Flash. Presented by Ken Cohen, PhD, PE & CIH (Ret.) Common Electrical Hazards in the Workplace Including Arc Flash Presented by Ken Cohen, PhD, PE & CIH (Ret.) 1 What s New In February 1972, OSHA incorporated the 1971 edition of the National Fire Protection

More information

mpm DIN 43650 CONNECTORS

mpm DIN 43650 CONNECTORS mpm DIN 43650 CONNECTORS : Highest quality, robust connectors for hydraulic and pneumatic electromechanical devices Broad offering of DIN 43650 connectors and devices Combined Brad and mpm cordsets : Provide

More information

All work must conform to the National Electric Code, latest edition, and all other applicable codes and regulations.

All work must conform to the National Electric Code, latest edition, and all other applicable codes and regulations. DIVISION 16 ELECTRICAL SECTION 16100 - ELECTRICAL PART 1 - GENERAL SCOPE All electrical work as shown on the drawings and as necessary to provide a complete electrical system. Include primary service,

More information

The Different Types of AC Power Connectors in North America

The Different Types of AC Power Connectors in North America The Different Types of AC Power Connectors in North America White Paper #20 Executive Summary A confusing array of AC power plugs and receptacles exist to deliver power to various electronic loads. This

More information

Industrial. Guest Battery Chargers & Accessories. Rev

Industrial. Guest Battery Chargers & Accessories. Rev Industrial Guest Battery Chargers & Accessories Rev C Why Guest We ll Test Any Battery/Charger Combination For You Guest has been an expert in battery and charging technology for over 30 years. We ll help

More information

NEC 2014 Code Changes

NEC 2014 Code Changes NEC 2014 Code Changes Articles 400-408.55 CHANGES FROM 2011 TO 2014 CODE ARE IN RED Chapter 4 Equipment for General Use ARTICLE 400 Flexible Cords and Cables 400.4 Types Flexible cords and flexible cables

More information

Pump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling

Pump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling Pump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling 250_P1 R10/7/2015 Copyright 2015 Liberty Pumps Inc. All rights reserved. Specifications subject to change without notice.

More information

D-13. temporary / mobile power. for harsh & hazardous (classfied) locations. Construction Demolition Maintenance Turnarounds Shutdowns

D-13. temporary / mobile power. for harsh & hazardous (classfied) locations. Construction Demolition Maintenance Turnarounds Shutdowns for harsh & hazardous (classfied) locations Construction Demolition Maintenance Turnarounds Shutdowns D-13 temporary / mobile power Temporary power products are used on industrial and construction sites

More information

ELECTRICAL GUIDELINES FOR SINGLE-FAMILY HOME OWNERS:

ELECTRICAL GUIDELINES FOR SINGLE-FAMILY HOME OWNERS: ELECTRICAL GUIDELINES FOR SINGLE-FAMILY HOME OWNERS: Chapter 12 of the Burlington Code of ordinances allows owner occupants of single family homes to do their own wiring if they choose. If you choose to

More information

IEC Connectors. Introduction

IEC Connectors. Introduction Introduction IEC Connectors A full range of quality mains rated inlets, outlets and connectors conforming to IEC and EN 60320 specifications carrying UL, CSA, VDE and other approvals. With electrical ratings

More information

Universal MATE-N-LOK Connector System

Universal MATE-N-LOK Connector System Universal MATE-N-LOK Connector System 2011 Tyco Electronics Corporation. All Rights Reserved. MATE-N-LOK, TE Connectivity, TE Connectivity (logo) and TE (logo) are trademarks. Other logos, products and/or

More information

Generator DoCKInG StatIonS

Generator DoCKInG StatIonS Generator DOCKING STATIONS TRYSTAR Portable Power Cable Cam to cam cable extensions 2000V, 100A-400A rated to NEC table 400.5 (B) All portable power cable sold is highly flexible and UL & C-UL or CSA Listed

More information

ELECTRIC KNIFE SHARPENER

ELECTRIC KNIFE SHARPENER PRODUCT MANUAL- M109 MODEL 401 ELECTRIC KNIFE SHARPENER Please read thoroughly before operation and keep for future reference Model 401 Knife Sharpener Specifications Model No. #401 Power Requirements

More information

For Models #6-5001, #6-7501, #10-7501 & #10-12K1

For Models #6-5001, #6-7501, #10-7501 & #10-12K1 EmerGen Switch Manual Transfer Switch Manufactured by CONNECTICUT ELECTRIC SWITCH MFG. CO. 1-800-730-2557 OWNER S MANUAL & INSTALLATION INSTRUCTIONS For Models #6-5001, #6-7501, #10-7501 & #10-12K1 PLEASE

More information

Electrical for Detached Garages: Updated Feb 19, 2016 for 2015 CE Code in force Jan. 1, 2016. Underground branch circuit feeding a detached garage:

Electrical for Detached Garages: Updated Feb 19, 2016 for 2015 CE Code in force Jan. 1, 2016. Underground branch circuit feeding a detached garage: Electrical for Detached Garages: Updated Feb 19, 2016 for 2015 CE Code in force Jan. 1, 2016 * Garage construction requires permits (electrical, building) * Permits must be applied for at the time. * Dial

More information

ORIGINAL CABLE PLATES

ORIGINAL CABLE PLATES Since 1998, DataComm Electronics has been pioneering innovative solutions for structured wiring. Industry-wide, we are known as the manufacturer who listens to customers, delivering the reliable and affordable

More information

Waterproof Connectors for Outdoor Use

Waterproof Connectors for Outdoor Use Waterproof Connectors for Outdoor Use HR41A Series Mated condition diagram Nut-tightening rear mount type (panel thickness=mm) 70.5 Features 1. Waterproof connector designed for outdoor use Light-weight

More information

INSTALLATION INSTRUCTION SPEC. SHEET 7/00. City of New York Calendar #40747 ETL LISTED UNDER U.L. STD. 2108 LOW VOLTAGE TRACK LIGHTING SYSTEM

INSTALLATION INSTRUCTION SPEC. SHEET 7/00. City of New York Calendar #40747 ETL LISTED UNDER U.L. STD. 2108 LOW VOLTAGE TRACK LIGHTING SYSTEM 7/00 INSTALLATION INSTRUCTION SPEC. SHEET 99052 99063 City of New York Calendar #40747 Copyright c 2000 ALFA Lighting, Inc. All rights reserved. Call:1-415-975-8080 QUICK JACK QJS R LISTED 9901483 ETL

More information

ED1259R5 Updated April 2011 For latest specs visit www.legrand.us/wiremold

ED1259R5 Updated April 2011 For latest specs visit www.legrand.us/wiremold Rack Power Distribution Solutions for IT/Network Environments Wiremold Power Commander Power Distribution Units offer comprehensive power distribution solutions for IT environments from networking solutions

More information

2900 & 3000 Series Commercial Duty Reels 4000 Series Industrial Duty Reels 5000-7000 Series Industrial Duty Reels 8000 Series Hazardous Location

2900 & 3000 Series Commercial Duty Reels 4000 Series Industrial Duty Reels 5000-7000 Series Industrial Duty Reels 8000 Series Hazardous Location 2900 & 3000 Series Commercial Duty Reels 4000 Series Industrial Duty Reels 5000-7000 Series Industrial Duty Reels 8000 Series Hazardous Location Reels SDR Series Grounding Reels Radio Controlled Specialty

More information

Arecont Vision H.264 Color or Day/Night SurroundVideo Series Installation Manual

Arecont Vision H.264 Color or Day/Night SurroundVideo Series Installation Manual 0 P a g e H.264 Color or Day/Night SurroundVideo Installation Manual Inside the box: A. Arecont Vision SurroundVideo camera B. Mounting template C. RJ45 female to female coupler D. Hex key E. Security

More information

Electrical Connection. Provide Proper Electrical Supply. Electrical Requirements. Connecting using the supplied cord and plug

Electrical Connection. Provide Proper Electrical Supply. Electrical Requirements. Connecting using the supplied cord and plug Electrical Connection When installed the range must be electrically grounded in accordance with local codes or; in the absence of local codes with the National Electrical Code ANSI/NFPA 70, latest edition.

More information

Cable Tie Mounting Bases

Cable Tie Mounting Bases Temperature Rating: 0ºC to 66ºC (32ºF to 150ºF) *Synthetic Rubber Adhesive Choose from adhesive-backed, epoxy or screw mounting bases! Available in a variety of materials for both indoor and outdoor use

More information

Arbiter Systems Test Leads: Engineered for Optimum Performance and Safety

Arbiter Systems Test Leads: Engineered for Optimum Performance and Safety Arbiter Systems Test Leads: Engineered for Optimum Performance and Safety Arbiter Systems, Inc. test equipment offers outstanding performance, flexibility, and value. Our test leads offer nothing less.

More information

Chromalox. Installation, Operation. Portable Industrial Unit Blower Air Heater Type DRA RENEWAL PARTS IDENTIFICATION

Chromalox. Installation, Operation. Portable Industrial Unit Blower Air Heater Type DRA RENEWAL PARTS IDENTIFICATION Chromalox Installation, Operation RENEWAL PARTS IDENTIFICATION Portable Industrial Unit Blower Air Type DRA and DIVISION SALES REFERENCE DATE SECTION (Supersedes P-) PF-) NOVEMBER, 00 DRA PF- -0-00 Specifications

More information

Network Connectivity. Your link for dependable routing of signal and data in industrial environments

Network Connectivity. Your link for dependable routing of signal and data in industrial environments Network Connectivity Your link for dependable routing of signal and data in industrial environments LynxPOWER Industrial Connectivity Realize time and cost savings with LynxPOWER Industrial Connectivity

More information

Electrical Safety Plugs What are the different types of plugs? Extension Cords What are some potential hazards involving extension cords?

Electrical Safety Plugs What are the different types of plugs? Extension Cords What are some potential hazards involving extension cords? Electrical Safety Electricity can be a friend, but it can also hurt if you do not treat it with respect. Everyday someone loses his or her home or business due to an electrical fire. These tragedies are

More information

SlimSeal SSL Connector. Now Available in 1 Position. Free Hanging Version

SlimSeal SSL Connector. Now Available in 1 Position. Free Hanging Version Now Available in 1 Position Free Hanging Version SlimSeal SSL Connector The SlimSeal SSL connectors are low profile, single row connectors developed for indoor and outdoor LED lighting applications. These

More information

TWIST-LOCK and HUBBELLOCK Devices

TWIST-LOCK and HUBBELLOCK Devices Section B TIST-LOCK and HUBBELLOCK Devices Index Rating Type Page Number 15A 125V 2P 2, Midget Twist-Lock Non-rounding Devices B-2 15A 125V 2P 2, Twist-Lock Non-rounding Devices B-3 20A 250V 2P 2, Twist-Lock

More information

Conduit Fittings & Accessories Directional Drilling Conduit Utility Duct Telephone Duct Residential Boxes

Conduit Fittings & Accessories Directional Drilling Conduit Utility Duct Telephone Duct Residential Boxes CANTEX INC. 301 Commerce Ste 2700 Fort Worth, Texas 76102 817-215-7000 Fax: 817-215-7001 Conduit Fittings & Accessories Directional Drilling Conduit Utility Duct Telephone Duct Residential Boxes YOUR FULL

More information

Bring power safely and conveniently to wherever

Bring power safely and conveniently to wherever Plug-In Outlet Center Units Plug-In Outlet Center Units Bring power safely and conveniently to wherever you need it with a full line of Plug-In Outlet Center Units from Wiremold/Legrand. These units are

More information

Utility Distribution Systems

Utility Distribution Systems Utility Distribution Systems 6/2012 A0011037 1 WARRANTY This equipment is warranted to be free from defects in materials and workmanship, under normal use and service, for a period of 12 months from date

More information

2011/2008/2005 NATIONAL ELECTRICAL CODE SOLAR PV CODE COMPLIANCE REFERENCE

2011/2008/2005 NATIONAL ELECTRICAL CODE SOLAR PV CODE COMPLIANCE REFERENCE 2011/2008/2005 NATIONAL ELECTRICAL CODE SOLAR PV CODE COMPLIANCE REFERENCE PAGE 1 OF 5 This Reference provides a very comprehensive list of aspects of a solar PV installation that could be reviewed, clarifying

More information

Mini USB and USB 2.0-IP67 Connector System

Mini USB and USB 2.0-IP67 Connector System Mini USB and USB 2.0-IP67 Connector System Section 12 Mini USB and USB 2.0-IP67 Connector System CONEC has added the Mini-USB connector. This Mini-USB IP67 receptacle and plug family, feature a bayonet

More information

Lighting Packages. 230 VAC Fluorescent Enclosure Light:

Lighting Packages. 230 VAC Fluorescent Enclosure Light: Spec-00581 H763.422.2211 763.422.2600 Electrical Lighting Packages Electrical Lighting Packages PANELITE Enclosure Lights Overview FEATURES Slim profile allows light to be tucked up out of the way for

More information

GROWTH MANAGEMENT DEPARTMENT 201 SE 3 rd ST, (Second Floor), Ocala, FL 34471 (352) 629-8421; FAX: (352) 629-8264

GROWTH MANAGEMENT DEPARTMENT 201 SE 3 rd ST, (Second Floor), Ocala, FL 34471 (352) 629-8421; FAX: (352) 629-8264 BUILDING CODE GUIDELINES FOR ELECTRICAL INSPECTIONS Building Code compliance is the obligation of design professionals and/or contractors. Plan Review and Inspection Guidelines are intended to be used

More information

Top Commercial / Residential Electrical Requirements *

Top Commercial / Residential Electrical Requirements * Department of Community Development Building Division 4800 West 92 nd Avenue Westminster, Colorado 80031 For Information call (303) 658-2075 Fax (303) 706-3922 www.westminsterpermits.com Top Commercial

More information

Quick Connect Boxes Inside Gloveboxes

Quick Connect Boxes Inside Gloveboxes ULC Series Junction Boxes Quick Connect Boxes Inside Gloveboxes The ULC quick connect junction boxes are the essential elements to optimize the cabling inside gloveboxes. Large range Designed for nuclear

More information

Application Bulletin 103 - NEC Reference Guide for SolarBridge-Enabled AC Module Installers

Application Bulletin 103 - NEC Reference Guide for SolarBridge-Enabled AC Module Installers 9229 Waterford Centre Dr. Bldg C, Suite 110 Austin, Tx 78758 Application Bulletin 103 - NEC Reference Guide for SolarBridge-Enabled AC Module Installers Current Version: 13 AC Modules are a new product

More information

HARTING Ethernet Cabling 4-poles Overview

HARTING Ethernet Cabling 4-poles Overview Ethernet Cabling 4-poles Overview RJ45 Connectors [on page 8] System cables [on page 10] Distribution modules and Outlets [on page 20] Connectors [on page 22] System cables [on page 24] Panel feed-throughs

More information

Pump Specifications 2448LSG, 2448LSGX Series Omnivore 2HP Simplex Grinder Packages

Pump Specifications 2448LSG, 2448LSGX Series Omnivore 2HP Simplex Grinder Packages Pump Specifications 2448LSG, 2448LSGX Series Omnivore 2HP Simplex Grinder Packages 2448LSG_P1 R4/2/2012 Copyright 2012 Liberty Pumps Inc. All rights reserved. Specifications subject to change without notice.

More information

CONTENTS. Yale University Design Standards. Underground Electrical Duct Bank. A. Summary. B. System Design and Performance Requirements

CONTENTS. Yale University Design Standards. Underground Electrical Duct Bank. A. Summary. B. System Design and Performance Requirements 16600 Underground Electrical Duct Bank This document provides design standards only, and is not intended for use, in whole or in part, as a specification. Do not copy this information verbatim in specifications

More information

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS PLEASE READ COMPLETE INSTRUCTIONS BEFORE YOU BEGIN LEAVE INSTALLATION INSTRUCTIONS AND USER'S GUIDE WITH OWNER ALL ELECTRIC WIRING AND PLUMBING MUST BE DONE

More information

Introduction. Safety Guidelines. Part Numbers. Operation and Maintenance Manual. Operation and Maintenance Manual

Introduction. Safety Guidelines. Part Numbers. Operation and Maintenance Manual. Operation and Maintenance Manual Operation and Maintenance Manual Introduction Read all instructions thoroughly. Installation of the OilTector must comply with all Federal, State and Local Codes, Regulations and Practices. The OilTector

More information

HIROSE ELECTRIC U.S.A. Fiber Optic VAR July, 2015

HIROSE ELECTRIC U.S.A. Fiber Optic VAR July, 2015 HIROSE ELECTRIC U.S.A. Fiber Optic VAR July, 2015 Fiber Optic VAR Program Hirose Launches Fiber Optic Cabling VAR Program to provide a complete fiber optic cable assembly and wire harness solutions to

More information

Industry s leader in labeling, graphics & identification CALL (847) 918-3700. www.fricknet.com

Industry s leader in labeling, graphics & identification CALL (847) 918-3700. www.fricknet.com Industry s leader in labeling, graphics & identification CALL (847) 918-3700 www.fricknet.com In this catalog you ll find a wide variety of solutions including: Posts & Flags pg. 3 High-visibility markers

More information

Table of Contents. www.hunterfan.com. What to Expect with. Preparation. Tools Needed. Wiring. Hanging the Fan. Blades. Motor Housing.

Table of Contents. www.hunterfan.com. What to Expect with. Preparation. Tools Needed. Wiring. Hanging the Fan. Blades. Motor Housing. www.hunterfan.com Table of Contents What to Expect with Your Installation 30 inches Hanging the Fan Wiring 8 Maintenance, Operation & Cleaning Light Kit 13??? 14 1 9 Troubleshooting 11 5 Blades Motor Housing

More information

400 Series - Mini USB Buccaneer

400 Series - Mini USB Buccaneer IP68 Sealed IP68 rated USB V2.0 performance Plug and play capability Shielded system Overmoulded cables Screw coupling PCB versions Dust and waterproof to EN60529 Data rates up to 480Mbs Hot pluggable,

More information

HARTING Ethernet Cabling 8-poles Overview

HARTING Ethernet Cabling 8-poles Overview Ethernet Cabling 8-poles Overview RJ45 Connectors [on page 8] System cables [on page 12] Distribution modules and Outlets [on page 17] Connectors [on page 20] System cables [on page 26] Panel feed-throughs

More information

EXLUX ECOLUX C-LUX LIGHTING. Explosion Protected Fluorescent Lighting Fixtures for Hazardous and Corrosive Applications

EXLUX ECOLUX C-LUX LIGHTING. Explosion Protected Fluorescent Lighting Fixtures for Hazardous and Corrosive Applications EXLUX ECOLUX C-LUX LIGHTING 6000 6008 6400 6408 6600 6608 6500 Explosion Protected Fluorescent Lighting Fixtures for Hazardous and Corrosive Applications Features: Electronic Ballasts For Fluorescent Bipin

More information

MR221-MR222 Heavy Duty Geared Limit Switches, CE Approved

MR221-MR222 Heavy Duty Geared Limit Switches, CE Approved MR221-MR222 Heavy Duty Geared Limit Switches, CE Approved MICRONOR automation components Product MICRONOR MR221 and MR222 series Heavy Duty Geared Limit Switches are for use in the most demanding industrial

More information

D e s c r i p t i o n a n d De s i g n Fe a t u r e s

D e s c r i p t i o n a n d De s i g n Fe a t u r e s R igp o w e r RMP II Se r i e s R igp o w e r RMP II Se r i e s D e s c r i p t i o n a n d De s i g n Fe a t u r e s RigPower, LLC s mission is to create new industry standards in industrial electrical

More information

ECA OVERVIEW INNOVATIVE POWER & DATA SOLUTIONS INNOVATIVE POWER & DATA SOLUTIONS

ECA OVERVIEW INNOVATIVE POWER & DATA SOLUTIONS INNOVATIVE POWER & DATA SOLUTIONS 10 Mountain View Drive Shelton, CT 06484 P: 800.521.3175 F: 203.924.6687 www.electri-cable.com INNOVATIVE POWER & DATA SOLUTIONS 2015 Electri-Cable Assemblies. ECA reserves the right to change pricing

More information

The Different Types of AC Power Connectors in North America

The Different Types of AC Power Connectors in North America The Different Types of AC Power Connectors in North America White Paper 20 Revision 1 by James Spitaels > Executive summary A confusing array of AC power plugs and receptacles exist to deliver power to

More information

gesis IP + Heavy Duty Class I, Zone 2

gesis IP + Heavy Duty Class I, Zone 2 gesis IP + Heavy Duty gesis IP+ 20i HD Z2 Heavy-Duty Connectors for Class 1, Zone 2 Hazardous Locations Catalog 2012 Catch the Next Wave in Modular Connections Plug & Go Heavy-Duty Connectors for areas

More information

AMP Power Series Connectors

AMP Power Series Connectors May 3, 2011 2011 Tyco Electronics Corporation. All Rights Reserved. TE Connectivity, TE Connectivity (logo) and TE (logo) are trademarks. Other logos, products and/or Company names might be trademarks

More information

Plug-In Outlet Center Units

Plug-In Outlet Center Units Plug-In Outlet Center Units Plug-In Outlet Center Units Wiremold Plug-In Outlet Center Units bring power safely and conveniently to wherever you need it. These units are ideal for use in a wide variety

More information

CUSTOM AUXILIARY FORWARD LIGHTING KIT

CUSTOM AUXILIARY FORWARD LIGHTING KIT -J0 REV. 0--0 CUSTOM AUXILIARY FORWARD LIGHTING KIT GENERAL Kit Number -0, 0000 Models This Custom Auxiliary Lighting Kit adds lamps and turn signals to 00 and later FLHX model motorcycles. Additional

More information

How To Power A Power Supply On A Powerline From A Power Source To A Power Box

How To Power A Power Supply On A Powerline From A Power Source To A Power Box Power Base AI Power Base AI Application Guide Table of Contents Product Overview Our Philosophy On Electrical... 4 System Overview... 5 Power Base AI Statement of Line.... 6 Power Base AI Components...

More information

The STRIKE Connector System

The STRIKE Connector System I N D U S T R I A L The STRIKE Connector System The STRIKE Connector System The STRIKE Connector System is designed for heavy duty equipment. It combines technical know how of DEUTSCH in connectors with

More information

Terminal Boxes in Glass Fiber Reinforced Polyester (GRP)

Terminal Boxes in Glass Fiber Reinforced Polyester (GRP) Features Variants options Glass fiber reinforced polyester (GRP) enclosures Suitable for installation in Zones 0, 1, 2, 21 and 22 Certified Ex e, Ex ia and Ex tb 16 enclosure size options Various terminal

More information

This product can be assembled to the baseplate maintaining 5 mm center-to-center spacing. Thus any number of poles can end-to-end stack.

This product can be assembled to the baseplate maintaining 5 mm center-to-center spacing. Thus any number of poles can end-to-end stack. page 1/5 Plug-in Screw Connector System for Printed Circuit Boards 950-NLFL-DS 5.00 mm (0.197 in) Spacing - 2-12 poles PICTURES 950-NLFL-DS 950-NLFL & 971-SLK TECHNICAL INFORMATION Description This two

More information

RESIDENTIAL ELECTRICAL REQUIREMENTS (REVISED 3/28/2008) PERMIT REQUIREMENTS:

RESIDENTIAL ELECTRICAL REQUIREMENTS (REVISED 3/28/2008) PERMIT REQUIREMENTS: RESIDENTIAL ELECTRICAL REQUIREMENTS (REVISED 3/28/2008) PERMIT REQUIREMENTS: Signed completed Electrical Permit application form. Minnesota law requires all electrical work is to be performed by licensed,

More information

LIEBERT VNSA Installation Sheet

LIEBERT VNSA Installation Sheet LIEBERT VNSA Installation Sheet Description The Liebert vnsa network switch is designed for connecting multiple Ethernet-ready devices and comes in various models. The unit may have: A Liebert icom display

More information

AMPSEAL* Automotive Plug Connector and Header Assembly

AMPSEAL* Automotive Plug Connector and Header Assembly AMPSEAL* Automotive Plug Connector and Header Assembly Application Specification 24 SEP 97 Rev E All dimensions are given in millimeters unless otherwise specified. All dimensional tolerances are +0.2

More information

Arktite Heavy Duty Circuit Breaking Plugs and Receptacles

Arktite Heavy Duty Circuit Breaking Plugs and Receptacles 1312-1313.qxp 12/16/2013 7:04 PM Page 1312 Arktite Heavy Duty Circuit Breaking Plugs and Receptacles Industrial Heavy Duty Non-hazardous Areas Features: Arktite circuit breaking plugs and receptacles are

More information

Replacement parts. WM97+ gas-fired water boiler Boiler Manual. OBTAIN PARTS ONLY THROUGH WEIL-McLAIN THE BOILER CONTAINS CERAMIC FIBER MATERIALS

Replacement parts. WM97+ gas-fired water boiler Boiler Manual. OBTAIN PARTS ONLY THROUGH WEIL-McLAIN THE BOILER CONTAINS CERAMIC FIBER MATERIALS Replacement parts DO NOT SERVICE THE BOILER WITHOUT A WM97+ MAINTENANCE KIT AVAILABLE Failure to adhere to these guidelines can result in severe personal injury, death or substantial property damage. The

More information

Installation and Operating Instructions (for chargers shown below)

Installation and Operating Instructions (for chargers shown below) Installation and Operating Instructions (for chargers shown below) For additional information please call our Technical Support Group 800.742.2740 PRO CHARGING SYSTEMS, LLC 1551 Heil Quaker Boulevard,

More information

Product Specification instalert Rapid Messenger Variable Message Sign

Product Specification instalert Rapid Messenger Variable Message Sign instalert 2 units to cover any application instalert 18 (ia18): 18 x 28 full matrix instalert 24: (ia24): 24 x 60 full matrix Size, Weight without battery ia18: 30 x 20 x 2.74, 29 lbs ia24: Folds to fits

More information

FASTON Terminals and Connectors

FASTON Terminals and Connectors Introduction Product Facts Straight, right-angle and receptacle-tab combinations available Receptacles available for 6.3 mm, 4.8 mm and 2.8 mm tab size (.250,.187 and.110 Series) Receptacles mate with

More information

Power Commander Power Distribution Units from Wiremold/Legrand offer

Power Commander Power Distribution Units from Wiremold/Legrand offer Power Commander Power Distribution Units Rack Power Distribution Solutions for IT/Network Environments Power Commander Power Distribution Units from Wiremold/Legrand offer comprehensive power distribution

More information

* Please visit the product pages on our website for the most up-to-date product information. Con-X Molded Cable Assembly Checklist...

* Please visit the product pages on our website for the most up-to-date product information. Con-X Molded Cable Assembly Checklist... TABLE OF CONTENTS Custom Molded Cable Assemblies and Connectors..........................2 Capabilities.....................................................................3 Standard Connector Products.......................................................4

More information

Standard Buccaneer - USB

Standard Buccaneer - USB IP68 rated USB version 2.0 performance Plug and play capability Visual mating indication Shielded system Single and double ended cables Screw coupling PCB versions Dust and waterproof sealing when mated

More information

Transfer Switch 30 Amps STS-30. Manual. Please read this manual before operating your transfer switch

Transfer Switch 30 Amps STS-30. Manual. Please read this manual before operating your transfer switch Transfer Switch 30 Amps STS-30 Owner's Manual Please read this manual before operating your transfer switch Section 1 Introduction Function of a Transfer Switch In case of failure of the main AC power

More information

USB 3.0 Cables. Color. Black Black Black Black Black 3021003-03 3021009-06 3021015-10 3021021-16 3021027-16. Black Black Black Black Black

USB 3.0 Cables. Color. Black Black Black Black Black 3021003-03 3021009-06 3021015-10 3021021-16 3021027-16. Black Black Black Black Black USB.0 CableS USB.0 and backwards compatible for USB.0 and. Supports high speed, 480Mbps Twisted-pair construction reduces cross talk to ensure error free transfer USB A male to USB B male 00-0 007-0 0-09-

More information

Part Name/Description Part Number Quantity. Power Cable 4000950-5 1

Part Name/Description Part Number Quantity. Power Cable 4000950-5 1 Note: Indented items indicate parts included in an assembly listed above Part Name/Description Part Number Quantity Power Cable 4000950-5 1 Raven Harness Adapter Kit 4100525 1 Installation Instructions

More information

PS4-24 OWNERS MANUAL 24 VAC 90 WATT WALL MOUNTED CCTV POWER SUPPLY

PS4-24 OWNERS MANUAL 24 VAC 90 WATT WALL MOUNTED CCTV POWER SUPPLY PS4-24 OWNERS MANUAL 24 VAC 90 WATT WALL MOUNTED CCTV POWER SUPPLY 7320 Ashcroft, Suite 104 Houston, Texas 77081 p: 713-772-1404 f: 713-772-7360 e: info@juicegoose.com www.juicegoose.com 06-06 CONGRATULATIONS

More information

Waekon Gold. Test Lead Master Kit. Tight Spot Test Lead Kit. Micro Mate Terminal Adapter Set. Magnetic Test Lead Ground Lug

Waekon Gold. Test Lead Master Kit. Tight Spot Test Lead Kit. Micro Mate Terminal Adapter Set. Magnetic Test Lead Ground Lug Sharp, adjustable depth contact tip to penetrate corrosion or metal coatings for a good connection. Limited Lifetime warranty. 1) Universal Magnetic Ground Lug Stop searching for a good place to clip your

More information

TOKISTAR. Exhibitor TOKISTAR LIGHTING

TOKISTAR. Exhibitor TOKISTAR LIGHTING TOKISTAR Exhibitor TOKISTAR LIGHTING Exhibitor TM T okistar Exhibitor Series is a wet-location festoon lighting system used in amusement parks, shopping centers, street decorations and promenades. Exhibitor

More information

Battery Chargers. Revised 8/00 Form Number 56041170 FORM NO. 56041170 / BATTERY CHARGER SERVICE MANUAL / PARTS LIST - 45

Battery Chargers. Revised 8/00 Form Number 56041170 FORM NO. 56041170 / BATTERY CHARGER SERVICE MANUAL / PARTS LIST - 45 Battery Chargers SERVICE MANUAL / PARTS LIST AUTOMATIC Advance MODELS 0980, 098, 797, 8809, 90, 880, 880, 099, 08,, 09788, 098, 7, 097, 70, 790, 889 Lester MODELS 007,, 8, 8, 89, 80, 9, 00, 00, 008 MANUAL

More information

B. Related Sections: 1. Section 26 05 33 - Raceway and Boxes for Electrical Systems.

B. Related Sections: 1. Section 26 05 33 - Raceway and Boxes for Electrical Systems. SECTION 262726 - WIRING DEVICES PART 1 - GENERAL 1.1 SUMMARY A. Section includes wall switches; wall dimmers; receptacles; multioutlet assembly; and device plates and decorative box covers. B. Related

More information

600V Power Cable 600V SOOW SOW

600V Power Cable 600V SOOW SOW 600V Power Cable Type SOOW UL/CSA 90 C 600V Part AWG No of Insulation Jacket Nominal Wieght/Mft Number Stranding conductors Thickness Thickness O.D. Nom. 18 2 SOOW 18 AWG 2.30 71 18 3 SOOW 16/.010 3.030

More information

IMPORTANT: BEFORE INSTALLING ANY HEATING TERMINAL UNIT TO A DOMESTIC WATER HEATER, CONSULT THE LOCAL PLUMBING CODES.

IMPORTANT: BEFORE INSTALLING ANY HEATING TERMINAL UNIT TO A DOMESTIC WATER HEATER, CONSULT THE LOCAL PLUMBING CODES. QUIET-ONE Environmental Products 2000 Kickspace Heater Series Models: KS 2004, KS 2006 KS 2008, KS 2010 INSTALLATION OPERATING MAINTENANCE Please read these instructions thoroughly before beginning your

More information