INTERCOM SYSTEM SECTION 3 (REV.A) Download from: Technical Manuals area BASIC DIAGRAMS INTERCOM SYSTEMS. sec.

Size: px
Start display at page:

Download "INTERCOM SYSTEM SECTION 3 (REV.A) Download from: Technical Manuals area BASIC DIAGRAMS INTERCOM SYSTEMS. sec."

Transcription

1 SECTION (REV.A) BASIC DIAGRAMS INTERCOM SYSTEM VOICE TONE POWER BUSY PRIV OCK TAK Download from: Technical Manuals area DOOR PHONE VIDEO DOOR PHONE SYSTEMS: Installation Diagrams sec.

2 INTERCOM SYSTEM Ref. 0 0 SECTION CONTENTS DOOR PHONE AND VIDEO DOOR PHONE SYSTEM DIAGRAM Diagram Sec. Pag. FEATURES INDICATORS AND CONTROS TENICA DATA Description All master intercom system Centralized system RECOMMENDATIONS FOR INSTAATION AND USE Wallmounted BASIC SYSTEM DIAGRAMS INTERCOM SYSTEM CONNECTION OF MASTER STATIONS...SC INTERCOM SYSTEM CONNECTION OF MASTER STATIONS...SC WITH SAVES CONNECTION OF MASTER STATIONS WITH SAVE UNITS TO MASTER STATIONS...SC CENTRAIZED SYSTEMS CONNECTION OF MASTER STATION WITH SAVE UNITS...SC CENTRAIZED SYSTEMS CONNECTION OF MASTER STATION WITH SAVE UNITS...SC DOOR PHONE AND VIDEO DOOR PHONE SYSTEM DIAGRAM Section DOOR PHONE VIDEO DOOR PHONE SYSTEMS: Installation Diagrams sec. I

3 Ref. 0 0 Ref. 0 0 FEATURES INDICATORS AND CONTROS TENICA DATA Ref. 0/0/ Ref. 0 VOICE TONE POWER BUSY PRIV OCK TAK VOICE TONE POWER BUSY PRIV OCK TAK Ref. 0 0 Ref. 0 Ref. FEATURES The Urmet DOMUS Intercom system can be used to set up two types of installations: intercom system with a maximum of intercoms (all master stations); centralized with one master station and a maximum of slave units. In the all master connection, all the stations can communicate with each other. It is possible to hold three simultaneous conversations with key intercoms and six simultaneous conversations with key intercoms. Several intercoms can be called in parallel pressing the call keys required at the same time. If intercoms are engaged in a conversation and a third intercom calls one of these, this is inserted automatically in the conversation. In a centralized connection, a master station can call or be called by up to slave units. In both systems, only three conductors are required, i.e. common wires plus one for each set. The system is powered by a centralized power supply. IMPORTANT: Respect a minimum distance when installing two devices which could interact in the same environment. The indicative distance of approximately ten meters can change significantly according to the type of environment. Ref. oudspeaker Station selection keys Voice volume adjustment (VOICE) Call volume adjustment (TONE) Intercom on indicator light (POWER) Intercom operating indicator light (BUSY) Secrecy key (PRIV) Continuous transmission key (OCK) Talkisten key (TAK) 0 Station selected indicator light Intercom cord Microphone 0 INDICATORS AND CONTROS TENICA DATA POWER SUPPY Voltage: Power: Power supply output: 0Vac 0Hz VA Vdc 0.Vdc Ref. 0 INTERCOMS Voltage: Vdc Max. current: 0mAdc Max. audio power: 00 mw Max. dimensions: Ref. 0 0 x x mm Ref. 0 and x x mm DESCRIPTION Single slave unit without socket for centralized systems Ref. 0 Centralized key intercom, master station with socket and cord Ref. 0 Centralized key intercom, master station with socket and cord Ref. 0V centralized power supply for bar mounting Ref. 00A DOOR PHONE VIDEO DOOR PHONE SYSTEMS: Installation Diagrams sec.

4 Ref. 0/0/ Ref. 0 0 RECOMMENDATIONS FOR INSTAATION AND USE A MASTER INTERCOM SYSTEM WAMOUNTED Call from another station Station A can call station B simply by pressing the call button of the station required. The BUSY light and the light of the call key of station A switch on to indicate that the communication has been established, while a. second electronic call and a visible warning (switching on of the BUSY light) are sent to station B. After the call, station B is already engaged in a conversation with station A. Device A to speak to device B must hold the TAK button pressed or switch the OCK button (freehands). Reply to the call When you hear the call tone, press the TAK key and speak into the intercom. Release the TAK key to listen. The PRIV key is used to interrupt or to prevent insertion of a station and listening by this to local conversations of a second station. CENTRAIZED SYSTEM Master station To call a slave unit, press the key of the unit required. The BUSY light and the call key of the master station will switch on, while a. second electronic call tone will ring on the slave unit. Press the TAK key to speak and release it to listen. Press the OCK key for handsfree conversation. At the end of the conversation, remember to reposition the OCK key and the call key of the slave unit to free the system and switch off the BUSY light. No operations are required to answer the call of a slave unit. Slave unit To call a main appliance, lower the key. The master station will receive an electronic call tone and the BUSY light will switch on at the same time. Press the TAK key to speak and release it to listen. At the end of the conversation, return to the key to the home position (raised). The PRIV key is used to interrupt or to prevent insertion of the master station and listening by this to the local conversations of a slave unit. Fasten the bracket to the wall with screws and wall bolts. Fasten the intercom unit to the brackets in the housings provided and fasten in place with the screw provided. Ref. 0 A RECOMMENDATIONS FOR INSTAATION AND USE In intercom systems, place the power supply unit at the center of the installation. To avoid inductive disturbances, do not lay conductors in conduits containing electrical, telephone lines, etc. When the intercoms are not used for a long time, disconnect the power supply unit from the mains. Do not expose the intercoms to rain or steam. Before connecting the power supply unit to the mains, switch off the main circuit breaker. Comply scrupulously with the indications regarding the power terminals of the power supply unit. On completion, replace the mains terminal protection cover. Heat dissipation slots must not be obstructed. Minimum diameter of the conductors: Distance (m) Diameter (mm) Crosssection (mm ) sec. DOOR PHONE VIDEO DOOR PHONE SYSTEMS: Installation Diagrams

5 FEATURES The system provides intercom service for up to seven devices. Three independent conversations can be established at the same time. A call can be made in parallel to several devices by pressing the required call buttons at the same time. A third device calling two devices during a conversation will be automatically included in the conversation in progress. Install two devices which can intercommunicate in the same environment at a distance of less than approximately ten metres. Ref. 0 0 INTERCOM SYSTEM CONNECTION OF MASTER STATIONS SC0: N. Intercom device with buttons Ref. 0 POWER SUPPY REFERENCE BASIC DIAGRAMS N. Power Supply Vdc Ref. 00A (see section ) C.0 SC0 V 0 Vac Power supply DOOR PHONE VIDEO DOOR PHONE SYSTEMS: Installation Diagrams sec.

6 BASIC DIAGRAMS FEATURES The system provides intercom service for up to seven devices. Three independent conversations can be established at the same time. Ref. 0 0 INTERCOM SYSTEM CONNECTION OF MASTER STATIONS SC0: A call can be made in parallel to several devices by pressing the required call buttons at the same time. A third device calling two devices during a conversation will be automatically included in the conversation in progress. Install two devices which can intercommunicate in the same environment at a distance of less than approximately ten metres. N. Intercom device with buttons Ref. POWER SUPPY REFERENCE N. Power Supply Vdc Ref. 00A (see section ) C.0 0 SC Power supply 0 Vac 0 V sec. DOOR PHONE VIDEO DOOR PHONE SYSTEMS: Installation Diagrams

7 FEATURES Ref. 0 0 WITH SAVES CONNECTION OF MASTER STATIONS WITH SAVE UNITS TO MASTER STATIONS The system provides intercom service for six main devices. Three independent conversations can be established at the same time. A call can be made in parallel to several devices by pressing the required call buttons at the same time. Two intercom phones () are respectively connected also to two intercom extensions (AB). Devices A and B can communicate only with the two main devices to which they are connected. SC0: N. Intercom device with buttons Ref. 0 N. Single slave unit Ref. 0 BASIC DIAGRAMS POWER SUPPY REFERENCE N. Power Supply Vdc Ref. 00A (see section ) C.0 B SC0 A Slave Master A B 0 Vac Power Supply DOOR PHONE VIDEO DOOR PHONE SYSTEMS: Installation Diagrams sec.

8 BASIC DIAGRAMS FEATURES Ref. 0 0 CENTRAIZED SYSTEMS CONNECTION OF MASTER STATION WITH SAVE UNITS This system provides intercom service between extensions and a main device. Calls can be made in parallel from the main device by pressing the required call buttons at the same time. The extensions can only call the main device. SC0: N. Intercom device with buttons Ref. 0 N. Single slave unit Ref. 0 POWER SUPPY REFERENCE N. Power Supply Vcc Ref. 00A (see section ) C.0 SC0 P Slave Master P V 0 Vac Power Supply sec. DOOR PHONE VIDEO DOOR PHONE SYSTEMS: Installation Diagrams

9 FEATURES Ref. 0 0 CENTRAIZED SYSTEMS CONNECTION OF MASTER STATION WITH SAVE UNITS This system provides intercom service between extensions and a main device. Calls can be made in parallel from the main device by pressing the required call buttons at the same time. The extensions can only call the main device. SC0: N. Intercom device with buttons Ref. N. Single slave unit Ref. 0 BASIC DIAGRAMS POWER SUPPY REFERENCE N. Power Supply Vdc Ref. 00A (see section ) C.0 SC0 0 P Master Slave P 0 0 Power Supply 0 Vac V DOOR PHONE VIDEO DOOR PHONE SYSTEMS: Installation Diagrams sec.

SECTION 3A (Rev.F) SECTION CONTENTS. Download from www.urmet.com Technical Manuals area. sec.3a INSTALLATION...9 TECHNICAL SPECIFICATIONS...

SECTION 3A (Rev.F) SECTION CONTENTS. Download from www.urmet.com Technical Manuals area. sec.3a INSTALLATION...9 TECHNICAL SPECIFICATIONS... SECTION 3A (Rev.F) Apartment door phone stations Download from www.urmet.com Technical Manuals area. ATLANTICO DOOR PHONES 2 TECHNICAL SPECIFICATIONS...2 4+n wire system door phones...2 Door phone with

More information

INSTRUCTIONS FOR URMET DOMUS DEVICE INTERCHANGEABILITY

INSTRUCTIONS FOR URMET DOMUS DEVICE INTERCHANGEABILITY SECTION F (REV.B) INSTRUCTIONS FOR URMET DOMUS DEVICE INTERCHANGEABILITY INSTRUCTIONS FOR URMET DOMUS DEVICE INTERCHANGEABILITY Download from: www.urmetdomus.com Technical Manuals area BASIC SYSTEM DIAGRAMS

More information

BIBUS VOP. large blocks of flats with switchboard and mixed mainly audio systems. Ideal for door phone systems with up to 250 users.

BIBUS VOP. large blocks of flats with switchboard and mixed mainly audio systems. Ideal for door phone systems with up to 250 users. BIBUS VOP Advice for use: large blocks of flats with switchboard and mixed mainly audio systems Ideal for door phone systems with up to 250 users VOP technology Easy creation of mixed audio and video door

More information

2 WIRE video door entry system

2 WIRE video door entry system J J N P CLASSE 00 VE WIRE video door entry system 5 Description Front view WIRE handsfree colour video handset with inductive loop, preset for different types of installations, depending on the accessories

More information

Doorbell Intercom Security System

Doorbell Intercom Security System Doorbell Intercom Security System POWER IN USE OFF A B C LOCK CALL TALK Installation Guide Model WHDB-301 EXPLANATION OF GRAPHIC WARNING SYMBOLS This symbol is intended to alert the user to the presence

More information

PS 29M DUAL CHANNEL BELTPACK IN METAL CASE

PS 29M DUAL CHANNEL BELTPACK IN METAL CASE PS 29M DUAL CHANNEL BELTPACK IN METAL CASE USER MANUAL October 2013 This product is designed and manufactured by: ASL Intercom BV Zonnebaan 42 3542 EG Utrecht The Netherlands Phone: +31 (0)30 2411901 Fax:

More information

BASIC DIAGRAMS FOR 4+N WIRE DOOR PHONE SYSTEMS

BASIC DIAGRAMS FOR 4+N WIRE DOOR PHONE SYSTEMS SECTION A (REV.D) DOOR PHONE SYSTEMS BASIC DIAGRAMS FOR 4N WIRE DOOR PHONE SYSTEMS Download from: www.urmetdomus.com Technical Manuals area sec.a DOOR PHONE SYSTEMS FUNCTION CONNECTION OF UP TO DOOR PHONES

More information

COLOR VIDEO DOOR PHONE CDV-71BE/D

COLOR VIDEO DOOR PHONE CDV-71BE/D COLOR VIDEO DOOR PHONE CDV-71BE/D 513-11, Sangdaewon-dong, Jungwon-gu, Seongnam-si, Gyeonggi-do, Korea Int l Business Dept. : Tel.; +82-31-7393-540~550 Fax.; +82-31-745-2133 Web site : www.commax.com Printed

More information

1 All safety instructions, warnings and operating instructions must be read first.

1 All safety instructions, warnings and operating instructions must be read first. ONYX USER MANUAL 2 Dateq ONYX Manual Safety instructions EN Safety instructions 1 All safety instructions, warnings and operating instructions must be read first. 2 All warnings on the equipment must be

More information

Monitors. Platea Monitor

Monitors. Platea Monitor Monitors Platea Monitor The common features of Platea monitors are: Casing manufactured in ABS RAL9003 white colour. 4" b/w flat tube screen or color TFT LCD of 'A Grade' quality. Brightness and contrast

More information

DS 1722-010B LBT 8546 SINGLE-FAMILY HANDS-FREE COLOUR VIDEO KIT WITH VIDEO DOOR PHONE ANSWERING SERVICE. Ref. 1722/71 USER HANDBOOK

DS 1722-010B LBT 8546 SINGLE-FAMILY HANDS-FREE COLOUR VIDEO KIT WITH VIDEO DOOR PHONE ANSWERING SERVICE. Ref. 1722/71 USER HANDBOOK Mod. 1722 DS 1722-010B LBT 8546 SINGLE-FAMILY HANDS-FREE COLOUR VIDEO KIT WITH VIDEO DOOR PHONE ANSWERING SERVICE Ref. 1722/71 USER HANDBOOK The CD supplied contains the handbook full version with traslation

More information

Enterprise Edge M7310 Quick Reference Guide

Enterprise Edge M7310 Quick Reference Guide Enterprise Edge M7310 Quick Reference Guide 2000 Nortel Networks P0908513 Issue 03 Your Enterprise Edge M7310 Telephone Shift button For using the top function of a dual-memory button. Display shows the

More information

Contractors Guide Central Inverter System Installation

Contractors Guide Central Inverter System Installation Contractors Guide Central Inverter System Installation Step By Step Procedures 2,200 Watt/VA 6 Step Installation 1. Mount Bottom Cabinet 2. Mount Top Cabinet 3. Install Batteries 4. Install Conduit 5.

More information

User Manual. Video Doorphone CDV-1020AQ

User Manual. Video Doorphone CDV-1020AQ User Manual Video Doorphone CDV-1020AQ 513-11, Sangdaewon-dong, Jungwon-gu, Seongnam-si, Gyeonggi-do, Korea Int l Business Dept. Tel. : +82-31-7393-540~550 Fax. : +82-31-745-2133 Web site : www.commax.com

More information

The power module is Feature Number 8800-F2-901.

The power module is Feature Number 8800-F2-901. Hotwire 8820 GranDSLAM AC to DC Power Supply Installation Instructions Document Number 8800-A2-GZ41-00 AC to DC Power Supply The AC to DC Power Supply consists of a power supply chassis and one or two

More information

TOA INTERCOM SYSTEM. TOA Corporation OPERATING INSTRUCTIONS

TOA INTERCOM SYSTEM. TOA Corporation OPERATING INSTRUCTIONS OPERATING INSTRUCTIONS TOA INTERCOM SYSTEM INTERCOM STATION HF-250M Please follow the instructions in this manual to obtain the optimum results from this unit. We also recommend you to keep this manual

More information

TYXIA. *2702178_Rev.1* Installation and User Guide. Wireless receiver. TYXIA RF 642-1 channel

TYXIA. *2702178_Rev.1* Installation and User Guide. Wireless receiver. TYXIA RF 642-1 channel Installation and User Guide TYXIA Wireless receiver TYXIA RF 642-1 channel DELTA DORE Bonnemain - 35270 COMBOURG - France E-mail : deltadore@deltadore.com Unit compliant with the requirements of directives:

More information

Sense Components. Sense monitor. Antenna assembly. External mounting kit Current sensors. Download the Sense app. Go to sense.com/app.

Sense Components. Sense monitor. Antenna assembly. External mounting kit Current sensors. Download the Sense app. Go to sense.com/app. Sense Components Sense monitor Antenna assembly External mounting kit Current sensors Download the Sense app. Go to sense.com/app Power cable Technical Specifications Sense is a home energy monitoring

More information

GSM Smart Switch USER GUIDE

GSM Smart Switch USER GUIDE GSM Smart Switch USER GUIDE GSM Smart Switch allows switching almost any appliance ON and OFF remotely via mobile network. It is designed to receive start/stop commands from specially coded messages or

More information

TELIKOU Intercom System. TM-200 Main Station. Instruction Manual

TELIKOU Intercom System. TM-200 Main Station. Instruction Manual Intercom System TM-200 Main Station Instruction Manual TELIKOU Systems All Rights Reserved I. Introduction Thank you for choosing TELIKOU intercom product. TM-200 main station is suitable for television

More information

HERZ-Thermal Actuators

HERZ-Thermal Actuators HERZ-Thermal Actuators Data Sheet 7708-7990, Issue 1011 Dimensions in mm 1 7710 00 1 7710 01 1 7711 18 1 7710 80 1 7710 81 1 7711 80 1 7711 81 1 7990 00 1 7980 00 1 7708 11 1 7708 10 1 7708 23 1 7709 01

More information

System Manual 1+n technology

System Manual 1+n technology System Manual 1+n technology Contents 1 1+n technology System description 3 2 Safety remarks 3 3 Configuration, conductor lengths 1+n system without video 4-5 1+n system with video 6-7 Overview 8 4 Device

More information

BT Big Button 100. User Guide

BT Big Button 100. User Guide BT Big Button 100 User Guide Welcome to your BT Big Button 100 phone Large buttons for easy dialling. Handsfree make and receive calls using the loudspeaker. One-touch 1571 button dials your network answering

More information

User Guide. Model 380260 Insulation Tester / Megohmmeter

User Guide. Model 380260 Insulation Tester / Megohmmeter User Guide Model 380260 Insulation Tester / Megohmmeter Introduction Congratulations on your purchase of Extech s Insulation Tester/Megohmmeter. The Model 380260 provides three test ranges plus continuity

More information

PT-6000 Power Tower INSTALLATION MANUAL SPECIFICATIONS

PT-6000 Power Tower INSTALLATION MANUAL SPECIFICATIONS PT-6000 Power Tower INSTALLATION MANUAL 10.5 9.75 12 22.75 10.75 MAXIMUM SOIL HEIGHT: DO NOT ALLOW FILL TO EXCEED THIS LEVEL! 11.5 4 4 13 Optional PT-BASE for new installations or when previous 2000/6000

More information

MAC-821SC-E. Centralized On-Off Remote Controller. English ÏÏËÓÈÎ. Русский [FOR INSTALLER] INSTALLATION MANUAL

MAC-821SC-E. Centralized On-Off Remote Controller. English ÏÏËÓÈÎ. Русский [FOR INSTALLER] INSTALLATION MANUAL Centralized On-Off Remote Controller MC-821SC-E [FOR INSTLLER] INSTLLTION MNUL English [ [ π À À π ] E XEIPI IO O H IøN E KT T H [ [MONTÖR Ç N] MONTJ ELK TBI ÏÏËÓÈÎ [ДЛЯ УСТАНОВИТЕЛЯ] РУКОВОДСТВО ПО УСТАНОВКЕ

More information

INSTALLATION GUIDE LOW VOLTAGE TRANSFORMER

INSTALLATION GUIDE LOW VOLTAGE TRANSFORMER INSTALLATION GUIDE LOW VOLTAGE TRANSFORMER 300W 600W 900W 1200W ATTENTION: Please read and understand thoroughly this installation guide to ensure safe and efficient operation of this Power Module 1 Open

More information

USER GUIDE. Studio Hotline Multi-line System Phone Flasher and Door/Alert Indicator Input Module and Indicator. DM Engineering. Version 1.

USER GUIDE. Studio Hotline Multi-line System Phone Flasher and Door/Alert Indicator Input Module and Indicator. DM Engineering. Version 1. USER GUIDE Studio Hotline Multi-line System Phone Flasher and Door/Alert Indicator Input Module and Indicator Version 1.3 DM Engineering 2174 Chandler St. Camarillo, CA 91345-4611 805-987-7881 800-249-0487

More information

GSM Door Phone System

GSM Door Phone System GSM Door Phone System System Installation, Setting and Operation Manual User Manual (263-S V1) Please read this user manual completely before operating this system and keep it in a safe place for future

More information

System Manual 1+n technology Issue 2013

System Manual 1+n technology Issue 2013 System Manual 1+n technology Issue 2013 Contents 1 1+n technology System description 3 2 Safety remarks 3 3 Configuration, conductor lengths 1+n technology 4-5 Overview 6 4 Device overview Door loudspeakers,

More information

Emergency lighting units EM powerled

Emergency lighting units EM powerled M BASIC 1 W Combined emergency lighting Driver 1 4 W Product description Emergency lighting Driver for manual testing SEV for output voltage < 60 V DC ow-profile casing (21 x 30 mm cross-section) 5-year

More information

3 IN 1 BATHROOM HEATER

3 IN 1 BATHROOM HEATER 3 IN 1 BATHROOM HEATER MODEL NO.: A515 - SH MINI FUNCTION: HEATER, EXHAUST FAN AND LIGHT Dear customers, Thank you for selecting the AUPU 3 in 1 Bathroom Heater. Please read all instructions before commencing

More information

4000 Series audio door entry system (using 9307.1 power supply) Installation Instructions IN9307.1

4000 Series audio door entry system (using 9307.1 power supply) Installation Instructions IN9307.1 Unit, AM Business Park umberland Avenue Park Royal, London, NW 7QL t : f : w : www.doorentrydirect.com 4 Series audio door entry system (using 7. power supply) Installation Instructions IN7. 7 Getting

More information

Radiant Temperature Sensor TY7321

Radiant Temperature Sensor TY7321 AB-5361-U Specifications/Instructions Radiant Temperature TY7321 General TY7321 Radiant Temperature s are designed to measure infrared radiation from perimeter windows and walls and provide a proportional

More information

Multimessage Systems Ltd

Multimessage Systems Ltd Telephone System Dealers stamp Installation Instructions User Guide Multimessage Systems Ltd. Unit 1 / 2 Cranborne Industrial Estate Cranborne Road, Potters Bar Herts. EN6 3JN Tel. 01707 644480 Fax 01707

More information

V-2901 UNIVERSAL DOOR ANSWERING SYSTEM

V-2901 UNIVERSAL DOOR ANSWERING SYSTEM VSP-V-2901 Issue 6 V-2901 UNIVERSAL DOOR ANSWERING SYSTEM INTRODUCTI The V-2901 is a Universal Door Answering System for use with any single line telephone, electronic or 1A2 key system, or PABX. These

More information

TELIKOU Intercom System. MS-500(4+1 channel) Main Station Instruction Manual

TELIKOU Intercom System. MS-500(4+1 channel) Main Station Instruction Manual TELIKOU Intercom System MS-500(4+1 channel) Main Station Instruction Manual TELIKOU Systems All Rights Reserved While TELIKOU makes every attempt to maintain the accuracy of the information contained in

More information

INSTALLATION DIAGRAMS

INSTALLATION DIAGRAMS SECTION 1 (REV.B) INSTLLTION IRMS ownload from: www.urmetdomus.com Technical Manuals area INSTLLTION IRMS OOR PHONE - VIEO OOR PHONE SYSTEMS: Installation iagrams sec.1 1 OOR PHONE N VIEO OOR PHONE SYSTEM

More information

98371000 REV. REL 1302 WEST BEARDSLEY AVENUE P.O. BOX 1127 ELKHART IN 46515 (574) 295-8330 FAX (574) 293-9914 2011 ELKHART BRASS MFG. CO., INC.

98371000 REV. REL 1302 WEST BEARDSLEY AVENUE P.O. BOX 1127 ELKHART IN 46515 (574) 295-8330 FAX (574) 293-9914 2011 ELKHART BRASS MFG. CO., INC. 81471067 Electric Monitor Motor Control Panel For use with Model 8394059 SPIT-FIRE Monitor Installation, Operation, and Maintenance Instructions FOR ATEX APPLICATIONS 1302 WEST BEARDSLEY AVENUE P.O. BOX

More information

DIGIVOICE. Large residential compounds with several entrances and stations with switchboard

DIGIVOICE. Large residential compounds with several entrances and stations with switchboard DIGIVOICE Advice for use: Large residential compounds with several entrances and stations with switchboard Only five common wires for making large size building compound systems Double conversation at

More information

2013 Wireless Video Intercom INSTALLATION GUIDE

2013 Wireless Video Intercom INSTALLATION GUIDE 2013 Wireless Video Intercom INSTALLATION GUIDE INDEX System configuration and wiring VL-SWD501 System Component.. 4 VL-SWD501EX wiring schematic diagram VL-SWD501EX wiring type and length... 5.... 6 Door

More information

User manual Rev 1.3 Contents

User manual Rev 1.3 Contents User manual Rev 1.3 Contents 1. Introduction...4 2. System specifications...5 2.1.. General overview...5 2.2. Maximum capacity...6 2.3. Electrical specifications...6 2.4. Mechanical specifications...6

More information

386 MY HOME Video door entry and home video surveillance system

386 MY HOME Video door entry and home video surveillance system 386 MY HOME Video door entry and home video surveillance system CTENTS MY HOME - Video door entry and home video surveillance system General features. 388 General rules for installation. 408 Wiring diagrams.

More information

SP 4K/5K Efecto & SP 5K Brilliant Parallel Installation Guide 1. Introduction

SP 4K/5K Efecto & SP 5K Brilliant Parallel Installation Guide 1. Introduction SP 4K/5K Efecto & SP 5K Brilliant Parallel Installation Guide 1. Introduction This inverter can be used in parallel with two different operation modes. 1. Parallel operation in single phase with up to

More information

4KVA/5KVA Parallel Installation Guide

4KVA/5KVA Parallel Installation Guide 4KVA/5KVA Parallel Installation Guide 1. Introduction This inverter can be used in parallel with two different operation modes. 1. Parallel operation in single phase with up to 4 units. The supported maximum

More information

Power supply unit Model: PAC-SC50KUA

Power supply unit Model: PAC-SC50KUA Building Air Conditioning Control System Power supply unit Model: PAC-SC50KUA Installation Manual Contents 1. Safety precautions... 1 2. Product feature... 2 1. Specification... 2 2. Appearance... 2 3.

More information

OM2260VW2 USER MANUAL VERIZON WIRELESS HOME PHONE CONNECT

OM2260VW2 USER MANUAL VERIZON WIRELESS HOME PHONE CONNECT OM2260VW2 USER MANUAL VERIZON WIRELESS HOME PHONE CONNECT Welcome to Verizon Wireless Thank you for choosing Verizon Wireless Home Phone Connect. You re now connected to the power of America s most reliable

More information

CONTENTS MY HOME - VIDEO DOOR ENTRY AND HOME VIDEO SURVEILLANCE SYSTEM

CONTENTS MY HOME - VIDEO DOOR ENTRY AND HOME VIDEO SURVEILLANCE SYSTEM CTENTS MY HOME Video door entry and home video surveillance system General features...................... 34 General rules for installation.............. 36 Wiring diagrams...................... 376 MY

More information

READ THIS MANUAL BEFORE PROCEEDING WITH THE INSTALLATION. FAILURE TO FOLLOW THE INSTALLATION INSTRUCTIONS MAY VOID YOUR WARRANTY!

READ THIS MANUAL BEFORE PROCEEDING WITH THE INSTALLATION. FAILURE TO FOLLOW THE INSTALLATION INSTRUCTIONS MAY VOID YOUR WARRANTY! READ THIS MANUAL BEFORE PROCEEDING WITH THE INSTALLATION. FAILURE TO FOLLOW THE INSTALLATION INSTRUCTIONS MAY VOID YOUR WARRANTY! The main power to any existing system must be disconnected prior to the

More information

Wireless Alarm system s manual

Wireless Alarm system s manual MOUNTVIEW TECH AUSTRALIA PTY LTD Wireless Alarm system s manual ADS A180 Series ADS Security 1/11/2011 1. Before You Begin For your safety and the safety of others, and to ensure that you get the most

More information

Operation Manual Magic Bowling. Warning Please read this manual carefully before using this machine

Operation Manual Magic Bowling. Warning Please read this manual carefully before using this machine Operation Manual Magic Bowling Warning Please read this manual carefully before using this machine Preface 1. Company profile: Zhongshan star amusement equipment Co., Ltd, ltd, which designs and manufactures

More information

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description Samba OPLC SM35-J-R20 Installation Guide The Unitronics SM35-J-R20 offers the following onboard I/Os: 12 Digital Inputs, configurable via wiring to include: 1 HSC/Shaft-encoder Input, 2 Analog inputs (only

More information

T7560A,B,C Digital Wall Module

T7560A,B,C Digital Wall Module T7560A,B,C Digital Wall Module HONEYWELL EXCEL 5000 OPEN SYSTEM BEFORE INSTALLATION All wiring must comply with local electrical codes and ordinances or as specified on installation wiring diagrams. Digital

More information

Example of use: Fuse for a solenoid valve. If the fuse is defective, no information is sent to the electronic component.

Example of use: Fuse for a solenoid valve. If the fuse is defective, no information is sent to the electronic component. Overview Switch and button modules The dimensions of the switch and button modules are adapted to the electronic components in the integral housing. The modules are equipped with the universal clip-on

More information

BeoLab 7-1 BeoLab 7-2. Guide

BeoLab 7-1 BeoLab 7-2. Guide BeoLab 7-1 BeoLab 7-2 Guide CAUTION: To reduce the risk of electric shock, do not remove cover (or back). No User-serviceable parts inside. Refer servicing to qualified service personnel. WARNING: To prevent

More information

GSM Desktop phone DPH101. User manual v1.00

GSM Desktop phone DPH101. User manual v1.00 GSM Desktop phone DPH101 User manual v1.00 LEGAL NOTICE Copyright 2011 TELTONIKA Ltd. All rights reserved. Reproduction, transfer, distribution or storage of part or all of the contents in this document

More information

SERIES 3400. PORTABLE COMMUNICATION SYSTEM with NOISE ATTENUATING HEADSETS STURDY CONSTRUCTION FOR RUGGED APPLICATIONS HANDS FREE COMMUNICATIONS

SERIES 3400. PORTABLE COMMUNICATION SYSTEM with NOISE ATTENUATING HEADSETS STURDY CONSTRUCTION FOR RUGGED APPLICATIONS HANDS FREE COMMUNICATIONS SERIES 3400 PORTABLE COMMUNICATION SYSTEM with NOISE ATTENUATING HEADSETS A SELF-CONTAINED PORTABLE COMMUNICATION SYSTEM CAN ACCOMMODATE UP TO 32 PEOPLE STURDY CONSTRUCTION FOR RUGGED APPLICATIONS HANDS

More information

CLARK COUNTY FIRE DEPARTMENT Fire Hazard & Prevention Services

CLARK COUNTY FIRE DEPARTMENT Fire Hazard & Prevention Services CLARK COUNTY FIRE DEPARTMENT Fire Hazard & Prevention Services 575 E. Flamingo Road, Las Vegas, NV 89119 (702) 455-7316 FAX (702) 455-7347 105.8a-6.1 TITLE: FIRE ALARM SYSTEM REQUIREMENTS SCOPE: This guideline

More information

Operating Instructions. Room temperature controller

Operating Instructions. Room temperature controller Operating Instructions 1. Area of application The room temperature controller is used to regulate the temperature in closed rooms such as flats, schools, function suites, workshops, etc. Safety instructions

More information

Telephone Controller INSTRUCTION MANUAL MODEL CT240-01

Telephone Controller INSTRUCTION MANUAL MODEL CT240-01 INSTRUCTION MANUAL Telephone Controller We thank you for trusting Aube technologies and hope that you will be entirely satisfied. For any questions concerning the CT240 telephone remote control, please

More information

Universal control module for motorized devices

Universal control module for motorized devices Ref: MOD-0105-N The MOD-0105-N is a universal module for motorized devices, blinds, awnings, curtains, doors, etc.. Allows, with vivimat BUS, the local or remote control of a motorized devices, ensuring

More information

MIC-WKT and MIC-WKT-IR

MIC-WKT and MIC-WKT-IR MIC-WKT and MIC-WKT-IR Installation Manual Bosch Security Systems EN Installation and Operation Manual MIC-WKTI and MIC-WKT-IR Installation Manual EN 2 MIC-WKT and MIC-WKT-IR Washer Pump Drive Card Kits

More information

Master Time Clock MTC-200 MTC-400 MTC-600. Users Manual

Master Time Clock MTC-200 MTC-400 MTC-600. Users Manual Master Time Clock MTC-200 MTC-400 MTC-600 Users Manual Toll Free (888)713-0373 Phone (972)987-4408 FAX (877)720-9291 www.midwest-time.com sales@midwest-time.com TABLE OF CONTENTS TOPIC PAGE GENERAL DESCRIPTION

More information

RY2 miniature industrial relays

RY2 miniature industrial relays 6 RY2 Relays of general application For plug-in sockets, 35 mm rail mount acc. to PN-EN 60715 or on panel mounting Flat insert connectors - faston x 0,5 mm Recognitions, certifications, directives: RoHS,

More information

AARC-EVAC Portable Hand Held or Fixed Transmitter with SOS assist - ATX43E25 SAFETY ALERT SYSTEMS

AARC-EVAC Portable Hand Held or Fixed Transmitter with SOS assist - ATX43E25 SAFETY ALERT SYSTEMS Wireless - Emergency Alert Systems Easy installation - Wireless Radio System no wires or wiring required Evacuation, Alert & Lockdown all in one system S.O.S Assist - up to 6 unique SOS assistance zone

More information

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points Features SELV Compliant No Detection Passive Injector Gigabit Compatible Full Protection

More information

USER MANUAL. KIT VIDEO DOOR PHONE 2 smart 1 family

USER MANUAL. KIT VIDEO DOOR PHONE 2 smart 1 family USER MANUAL EN KIT VIDEO DOOR PHONE smart 1 family Harry Johnston Call from the outdoor panel keys; Possibility to see on the terminal's display the person calling ; Duplex hands-free audio communication;

More information

Inverter / Charger Installation General Operations and AC and DC Connections

Inverter / Charger Installation General Operations and AC and DC Connections Inverter / Charger Installation General Operations and AC and DC Connections The Inverter is just one piece. Sometimes, a tendency is to mount the inverter and batteries, and make it work It is better

More information

Quick Reference Guide

Quick Reference Guide Important Information Digital Proprietary Telephone Quick Reference Guide Model No. KX-T7665 When using the KX-T7665, keep the following conditions in mind. If there is any problem, unplug the extension

More information

T0118 T2118 T3118. Instruction Manual

T0118 T2118 T3118. Instruction Manual Programmable indoor transmitter of temperature T0118 Programmable indoor transmitter of atmospheric pressure T2118 Programmable indoor transmitter of temperature, relative humidity and other derived humidity

More information

Active Speaker System LX523 AUDAC PROFESSIONAL AUDIO EQUIPMENT. Active Speaker System with remote input LX523. User Manual & Installation Guide

Active Speaker System LX523 AUDAC PROFESSIONAL AUDIO EQUIPMENT. Active Speaker System with remote input LX523. User Manual & Installation Guide Active Speaker System LX523 AUDAC PROFESSIONAL AUDIO EQUIPMENT Active Speaker System with remote input LX523 User Manual & Installation Guide AUDAC PROFESSIONAL AUDIO EQUIPMENT User Manual & Installation

More information

Video Camera Installation Guide

Video Camera Installation Guide Video Camera Installation Guide The intent of this guide is to provide the information needed to complete or modify a video camera installation to avoid lightning and induced power surge damage. This guide

More information

2M IR Mini Dome Quick Installation Guide

2M IR Mini Dome Quick Installation Guide 2M IR Mini Dome 2M IR Mini Dome Quick Installation Guide Please follow the installation steps below to set up 2M IR Mini Dome IP Camera. Check the package contents against the list below. See P.1 Physical

More information

Manufactures of: All. Dallas Delta Corporation Pty.Ltd. Pty.Ltd. 102 Albert St. East Brunswick, 3057 Vic. Tel: 613 93877388 Fax: 613 93873128

Manufactures of: All. Dallas Delta Corporation Pty.Ltd. Pty.Ltd. 102 Albert St. East Brunswick, 3057 Vic. Tel: 613 93877388 Fax: 613 93873128 Dallas Delta Corporation Pty.Ltd. 102 Albert St. East Brunswick, 3057 Vic. Tel: 613 93877388 Fax: 613 93873128 Email: sales@dallasdelta.com.au www.dallasdelta.com.au LP GUARD DOORSTATION MK II G UARD Doorstation

More information

Video Kits. For Villas. Rock vandal resistant panel

Video Kits. For Villas. Rock vandal resistant panel Video 5 wires Video 2 wires Video Kits Rock vandal resistant panel Injected aluminium vandal resistant (IK-09) and weatherproof (IP-44) door panels, in grey colour. Adjustable pan and tilt CCD b/w or color

More information

16/32 Channel 1U Rack Mount CCTV Power Supply

16/32 Channel 1U Rack Mount CCTV Power Supply 16/32 Channel 1U Rack Mount CCTV Power Supply Manual PH-A3224-GUQ Shown 16-Channel 32-Channel PTC PH-A1612-PUQ PH-A3224-PUQ Glass Fuse PH-A1612-GUQ PH-A3224-GUQ Industrial design 12 Amp 3 Amps per channel

More information

NELSON VOLTAGE MONITOR INSTALLATION & PROGRAMMING MANUAL

NELSON VOLTAGE MONITOR INSTALLATION & PROGRAMMING MANUAL NELSON VOLTAGE MONITOR INSTALLATION & PROGRAMMING MANUAL CONTENTS GENERAL INFORMATION...3 INSTALLATION...3 FIELD WIRING...4 PROGRAMMING...4 Circuit Monitor Options...5 Power Frequency...5 Alarm Silence

More information

Installation Guide. DEVIreg 530. Electronic Thermostat. www.devi.com

Installation Guide. DEVIreg 530. Electronic Thermostat. www.devi.com Installation Guide DEVIreg 530 Electronic Thermostat www.devi.com The English language is used for the original instructions. Other languages are a translation of the original instructions. (Directive

More information

AUDIO VIDEO INTERCOM SYSTEMS SECURITY & SAFETY AT YOUR FINGER TIPS AUDIO VIDEO INTERCOM SYSTEMS

AUDIO VIDEO INTERCOM SYSTEMS SECURITY & SAFETY AT YOUR FINGER TIPS AUDIO VIDEO INTERCOM SYSTEMS AUDIO VIDEO INTERCOM SYSTEMS SECURITY & SAFETY AT YOUR FINGER TIPS AUDIO VIDEO INTERCOM SYSTEMS 1 DORANI VIDEO INTERCOM - 2 WIRE SERIES 7 TFT MONITOR TECHNICAL SPECIFICATIONS 7 Colour TFT screen 480 x

More information

ACS-30-EU-EMDR-10-MOD

ACS-30-EU-EMDR-10-MOD Multi-application heat tracing Control and Monitoring in commercial and residential buildings Roof & Gutter de-icing sensor module Technical Information Approvals Module IP rating Ambient operating temperature

More information

alpha DSL WTM EG Instructions for use ADSL-Modem alpha DSL WTM EG

alpha DSL WTM EG Instructions for use ADSL-Modem alpha DSL WTM EG alpha DSL WTM EG Instructions for use ADSL-Modem alpha DSL WTM EG Safety precautions Safety precautions The DSL modem alpha DSL WTM EG complies with the European norm EN60950 safety of information technology

More information

REGULINE 600VA / 1000VA REGULATOR USER MANUAL

REGULINE 600VA / 1000VA REGULATOR USER MANUAL REGULINE 600VA / 1000VA REGULATOR USER MANUAL TUNÇMATİK REGULINE SERIES AUTOMATIC VOLTAGE REGULATOR Models: REGULINE 600VA / REGULINE 1000VA Principle of Operation Automatic Voltage Regulators regulate

More information

UK s best selling phone brand. User Guide. BT Big Button 200 Corded Phone

UK s best selling phone brand. User Guide. BT Big Button 200 Corded Phone UK s best selling phone brand User Guide BT Big Button 200 Corded Phone 2 Welcome. to your BT Big Button 200 telephone Large buttons for easy, accurate and more comfortable dialling Large display to assist

More information

Enterphone Solo. User/Installation Manual Part No. 421-2001

Enterphone Solo. User/Installation Manual Part No. 421-2001 Enterphone Solo User/Installation Manual Viscount Communication and Control Systems Inc. 4585 Tillicum Street, Burnaby, B.C., Canada V5J 5K9 Phone: (604) 327-9446 Toll Free: 1-800-476-3774 Fax: (604) 327-3859

More information

HMI display Installation Guide

HMI display Installation Guide HMI display Installation Guide Product Description Specifications Important Information o Package Contents o Related Documents o Accessories Cautions and Warnings Mounting and Dimensions o BAC-DIS-ENC

More information

Mounting and operating instructions. Surface-mounted hands-free feature home station 1250..

Mounting and operating instructions. Surface-mounted hands-free feature home station 1250.. Mounting and operating instructions Surface-mounted hands-free feature home station 1250.. Device description The surface-mounted hands-free feature home station is a prefabricated unit and is part of

More information

CHAPTER 4 UTILITY SYSTEMS ELECTRICAL. Utility Systems Electrical. Main Panel

CHAPTER 4 UTILITY SYSTEMS ELECTRICAL. Utility Systems Electrical. Main Panel CHAPTER 4 UTILITY SYSTEMS ELECTRICAL Utility Systems Electrical The electrical supply to your home begins outside, where you will see either an overhead feed and piping down the side of your home or (if

More information

2012 Canadian Electrical Code, Part I (CEC) Top Fifteen changes

2012 Canadian Electrical Code, Part I (CEC) Top Fifteen changes 2012 Canadian Electrical Code, Part I (CEC) Top Fifteen changes 1) Tamper resistant receptacles. 2009 CEC Required in dwelling units 2012 CEC Expanded to child care facilities First introduced in the 2009

More information

Inductive Proximity Sensors

Inductive Proximity Sensors M12 Inductive Proximity Sensors Standard Length Mini's Extended Sensing 3 Wire DC 2 Wire DC 2 Wire AC (Wiring Schematic) 3 Wire DC PNP Normally Open (1) IMM32122C IMM35124C IMN32122C IMN35124C IMN32122M12

More information

Quick Reference Guide

Quick Reference Guide Important Information Digital Proprietary Telephone Quick Reference Guide Model No. KX-T7665 When using the KX-T7665, keep the following conditions in mind. If there is any problem, unplug the extension

More information

Automatic Telephone Dialer TD-101(W)

Automatic Telephone Dialer TD-101(W) Automatic Telephone Dialer TD-101(W) The TD-101 is an automatic dialing device which can transmit prerecorded information via the telephone line. The dialer can send two different 10 second voice messages

More information

MOUNTING AND OPERATING INSTRUCTIONS

MOUNTING AND OPERATING INSTRUCTIONS MOUNTING AND OPERATING INSTRUCTIONS CF 51/55 1. Delivery CF 51/55-1 calculator with battery (optionally with mains power supply) - 1 wall mounting bracket - package with material for sealing, screws, wall

More information

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application 33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application Features Compliant with the IEEE802.3at Standard -40 to +60 C Temperature Range Diagnostic LEDs Full Protection

More information

Contact Details. Please note that some of the contact details on this PDF document may not be current.

Contact Details. Please note that some of the contact details on this PDF document may not be current. Contact Details Please note that some of the contact details on this PDF document may not be current. Please use the following details if you need to contact us: Telephone: 0844 879 3588 Email: customer.services@gdcgroup.co.uk

More information

User Manual Color video door phone

User Manual Color video door phone User Manual Color video door phone CDV-70KM Thank you for purchasing COMMAX products. Please carefully read this User s Guide (in particular, precautions for safety) before using a product and follow instructions

More information

Application/Connection Examples

Application/Connection Examples This Quick Start Guide is designed to familiarize the user with the connection and configuration of the DTS-305 DIN rail mounted single / 3 phase power & energy meter with RS-485 or TCP communications.

More information

2 Wire Electronic Time Delay Switch. 2 Wire Slave Switch. 3 Wire Electronic Time Delay Switch

2 Wire Electronic Time Delay Switch. 2 Wire Slave Switch. 3 Wire Electronic Time Delay Switch 2 Wire Electronic Time Delay Switch Cat No. DS1 2 Wire Slave Switch Cat No. DSS 3 Wire Electronic Time Delay Switch Cat No. DS2 Installation & Operating Instructions DS1/DSS Instructions for Installation

More information

GLOLAB Two Wire Stepper Motor Positioner

GLOLAB Two Wire Stepper Motor Positioner Introduction A simple and inexpensive way to remotely rotate a display or object is with a positioner that uses a stepper motor to rotate it. The motor is driven by a circuit mounted near the motor and

More information

HM-W536 Install Guide

HM-W536 Install Guide HM-W536 Install Guide 9/13/2013 IMPORTANT SAFETY INSTRUCTIONS Warning - When using electrical devices, basic safety precautions should be followed to reduce the risk of fire, electrical shock or injury.

More information

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q605 0054 R0001

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q605 0054 R0001 Analogue Input, -fold, MDRC, GH Q605 005 R0001 The analogue input is a DIN rail mounted device for insertion in the distribution board. It is connected to the EIB via the bus connecting terminal supplied.

More information