Portable Power Panels

Size: px
Start display at page:

Download "Portable Power Panels"

Transcription

1 Portable Power Panels

2 TRYSTAR PRODUCT Portable Power Cable NAME Cam to cam cable extensions TRYSTAR Portable Power Cable Pig tails, male or female, any length 2000V, 100A-400A rated to NEC table (B) All portable power cable sold is highly flexible and UL & C-UL or CSA Listed MSHA Listed Dual layer jacket with inner safety liner of contrasting color Available in any color, including 208V & 480V phases Your custom print on every foot of the cable All cables are factory tested 2000V, 100A-400A rated to NEC table (B) All portable power cable sold is highly flexible and UL & C-UL or CSA Listed MSHA Listed Dual layer jacket with inner safety liner of contrasting color Available in any color, including 208V & 480V phases Cam style to bare end with pin lugs or compression lugs available Your custom print on every foot of the cable All cables are factory tested Generator Docking Stations Distribution equipment Cable with integrity Compression lug Pin lug Bare end TRYSTAR fax trystar.com TRYSTAR fax trystar.com 3

3 PRODUCT TRYSTAR 50A NAME Traditional and hanging Tuff Box TRYSTAR 400A 3 Phase Tuff Box TRADITIONAL TUFF BOX: 50A input & feed through, 6 x 20A GFCI & 30A 125/250V receptacle Noncorrosive tuff box powder coated in aluminum or stainless steel Available on legs or in a cage UL 1640 Listed, C-UL 50 Listed enclosure, NEMA 3R hanging TUFF box: 50A input, up to 6 x 20A full GFCI duplex output (other receptacles available) Noncorrosive tuff box powder coated in aluminum or stainless steel Stainless steel feet with protective coating Main load center with changeable breakers Stainless steel hanging bracket with protective coating UL 1640 Listed, C-UL 50 Listed enclosure, NEMA 3R 400A three phase input & output or dead end configuration available Four receptacle positions available on two sides (feed through) Six receptacle positions available on three sides (dead end) Powder coated aluminum panels available in a variety of colors, or stainless steel Tri-fold stainless steel feet or stackable stainless steel frame Various receptacle configurations available UL Listed Portable Power Distribution Panel Red Safety Yellow Safety Orange Green Blue Yellow White Copper Round Frame 3 phase Dead end Tuff box with RV receptacles Feed through Tuff box with military receptacles Feed through Tuff box with 50A receptacles TRYSTAR fax trystar.com TRYSTAR fax trystar.com 5

4 TRYSTAR Convertible 400A Tuff Panel PRODUCT TRYSTAR Quad NAMEBox Stringer 400A three phase input & output or dead end configuration available Various receptacle configurations available, up to ten per panel Full load center with Square D Visitrip breakers UL Listed Portable Power Distribution Panel Powder coated aluminum panels available in a variety of colors, or stainless steel 10/5 or 12/5 SOOW, 20A/30A with M/F NEMA L21-20/L21-30 Each stringer consists of three rubber boxes All three boxes run on their own independent circuit Choice of either watertight or standard industrial plugs and connectors 3 in 1 versatility, standard bracket for generator door mounting, feet for free standing or rolling stackable frame Convertible from spider box to quad box, RV or other Three phase high intensity LED lighted indicators Receptacles available in GFCI and/or Edison style Each quad box is factory tested to full ampacity prior to shipment Bonding assembly eliminates heat and resistance buildup Hinged deadfront with quarter turn locking latches for easy access Breakout panel Feed through Tuff panel with multiple receptacle configurations Made to hang on a generator 400A pass through quad box panel Quad box extensions Extension cords TRYSTAR fax trystar.com TRYSTAR fax trystar.com 7

5 TRYSTAR VersaQuad Set PRODUCT TRYSTAR Banded NAME cable 10/5 or 12/5 SOOW, 20A/30A with M/F NEMA L21-20/L21-30 Bonding assembly eliminates heat and resistance buildup 100% slack elimination ensures the VersaQuad will not pull apart L1-L2-L3 are separate, balancing load and making for easy storage Each quad box is factory tested to full ampacity prior to shipment 190A or 220A, rated for use with NEC table 400.b UL Listed portable power cable Banded every 2 feet to ensure cables will not come apart Black, red and blue duplex receptacles designate phases Highly flexible cable Covers attached with six mounting screws rather than two for added stability and safety Vary spacing between VersaQuads by using 10, 25, 50 and 100 ft extensions Dual layer jacket with inner safety liner of contrasting color Available in any color, including 208V & 480V phases Free custom printing on every foot of the cable All cables are factory tested Trystar heavy duty quad boxes 60 foot quad box stringer VersaQuad set Distribution equipment layout Tuff panel I-Line panel TRYSTAR fax trystar.com TRYSTAR fax trystar.com 9

6 TRYSTAR Pin and Sleeve TRYSTAR 3 Gang Box Up to 400A available Meltric, IEC, Milspec and other heavy duty connectors available UL Listed plugs, connectors and cable Receptacles and back boxes also available Flanged inlet or cord mount inputs using L21-20 device Three receptacles ranging from 15 to 50 amp (standard is 20A GFCI) Stainless legs or rubber grommet feet Powder coated aluminum panels available in a variety of colors, or stainless steel UL Listed Portable Power Distribution Panel Meltric pin & sleeve Cam pin/sleeve adaptor 800A Portable I-Line panel Shown in white 50A input w/ 20A breakers & receptacles Rubber 3 gang TRYSTAR fax trystar.com TRYSTAR fax trystar.com 11

7 PRODUCT TRYSTAR 400A NAME & 800A Horizontal I-Line TRYSTAR Convertible I-Line Panels 1 or 2 x 400A independent inputs to 1 or 2 x 400A load centers Flexible breaker interior with hinged deadfront Stackable frame with 8 pnuematic wheels, forklift pockets & lifting eyes Powder coated aluminum enclosure and frame Front foldable handle and wheels enable easy portable positioning Holds up to 5 x 4-1/2 I-Line breakers per 400A load center Hard wire and cam lok inputs/outputs Breakers are isolated from input power with separate doors Convertable output recepacle options UL Listed Portable Power Distribution Panel Factory tested, NEMA 3R Up to 600V, 800A and 1200A available Cam style or hardwire input available Modular breaker interior with hinged deadfront Heavy duty frame with castors, forklift pockets & lifting eyes Adjustable tamper resistant undercarriage with lockable trap door Powder coated aluminum panels available in a variety of colors, or stainless steel Convertible receptacles allow for a single panel to have many uses from cam style to pin/sleeve to hard wire Variety of receptacles, wide range of breakers 20A-800A 120V-600V UL Listed Portable Power Distribution Panel Panel mounts with Trystar covers Breaker and hard wire doors Breaker door view Swing doors Simple access for easy conversion Cam style inputs on back TRYSTAR fax trystar.com TRYSTAR fax trystar.com 13

8 TRYSTAR Dolly Style Transformers PRODUCT TRYSTAR Ventilated NAME Transformers Encapsulated 15KVA or 30KVA step down (480V to 208V) or step up (208V to 480V) Any distribution panel configuration available Three phase or single phase available Aluminum dolly frame with load assist liberator feature Powder coated aluminum panels available in a variety of colors, or stainless steel UL Listed transformer & power distribution panel From 45KVA to 300KVA, step up or step down, to/from a variety of voltages Primary and secondary breakers available Three phase or single phase available Powder coated heavy duty stackable frames with castors, forklift pockets and lifting eyes Powder coated aluminum panels available in a variety of colors, or stainless steel UL Listed transformer & power distribution panel Option for swing door access to coils for ease of re-tapping 30KVA Encapsulated 30KVA in upright position Portable dolly Mobile/stackable Swing door option Re-tappable TRYSTAR fax trystar.com TRYSTAR fax trystar.com 15

9 PRODUCT TRYSTAR 800A NAMEDistribution Panel Trystar Injection MoLDing 2 x 400A independent inputs to 2 x 400A load centers Uses standard cam style inputs Flexible breaker interior with hinged deadfront Heavy duty frame with castors, forklift pockets & lifting eyes Powder coated stainless steel construction Folding wing doors, easy closing for shipping Quad Box Guardian, NEMA 3R with extension cords plugged in and in use Variety of receptacles, wide range of breakers 20A-800A 120V-600V UL Listed Portable Power Distribution Panel Factory Tested, NEMA 3R Trystar molded 16 series clear gasketed flip lids Doors open and fold out Independent inputs Variety of receptacles Trystar GFCI and Duplex covers / Heavy duty springs enable cover to fully close over receptacle when in the closed position TRYSTAR fax trystar.com TRYSTAR fax trystar.com 17

10 PRODUCT TRYSTAR Electric NAME mobile coiler TRYSTAR PORTABLE POWER CABLE (UL) C(UL) Available in: Custom COLOR, Any Length, CUT, COILED, COMPLETE With CONNECTOR ASSEMBLY 1 coil every 30 seconds Castors with floor locks Adjustable speed control Cable guide Coils spider box, quad box and power cable extensions Powder coated aluminum available in a variety of colors, or stainless steel FEATURES Available colors: Black, blue, red, green, white, yellow, orange, brown or custom Extra Flexible Class K (ASTM-B) Bare annealed copper stranding -45 C to 105 C, 2000 Volt Rating, flame retardant Resistant to oil, water, acid, gas, ozone, cuts, tears and abrasion (UL) 2000 volt rating, C(UL) 600 volts continuous use Manufactured to (UL) & C(UL) standard 1650 MSHA Listed RoHS Compliant Surpasses NEC 400 requirements and may be used in any application where Type W, G or G-GC cable is used APPLICATIONS Designed for use with industrial equipment, including portable generators, chillers, air conditioners, motor and welding leads, submersible wells, heavy tools, power extensions, marine dockside, mining and oil drilling applications, where long-term, quality performance at all operating temperatures is desired. CONSTRUCTION Conductor Bare, annealed electrolytic copper 30 AWG Class K rope lay stranding DUAL INSULATED JACKETING TECHNOLOGY Inner Jacket- Added for Your Safety A separator of high contrast color is applied between the conductor and outer sheath for your added safety. This provides increased insulation, added flexibility, and allows you to easily identify damage or wear. Outer Jacket TYPE PPE (FT5) provides oil, water, acid, gas, ozone, resistance, flame retardant, durability and extreme flexibility at all operating temperatures. Indented into outer jacket: (UL) TYPE PPE 90 C DRY 75 C WET SUN RES 2000V E P-07-KA MSHA AWG 4/0 C(UL) PPC/TPE FT5 90 C SUN RES 600V AVAILABLE SIZES, SPECIFICATIONS & AMPERAGE CORRECTION FACTORS TEMPERATURE CORRECTION FACTORS ** Size Stranding Strand Nominal OD Finished Nominal OD Weight lbs. / M FT Ampacity* Ambient Temp C FACTOR Ambient Temp F Number of Conductors Temperature Adjustment x x x x x / x / x / x / x % % % % % % D RATING FOR CONDUIT OR TRAY APPLICATION Enclosed cable storage reel Plastic collapsible bins Black metal storage vault % Adjustment factor for more than three current carrying conductors * For ambient temperatures other than 30 C (86 F) multiply the allowable ampacities stated above by the appropriate conversion factor. ** Indented into sheath: (UL) TYPE PPE 90 C DRY 75 C WET SUN RES 2000V E P-07-KA MSHA AWG 4/0 C(UL) PPC/TPE FT5 90 C SUN RES 600V *** Values Listed are for single conductors, where the individual conductor is not installed in raceways or physical contact with each other except in the lengths not exceeding 24.0 inches TRYSTAR fax trystar.com TRYSTAR fax trystar.com 19

11 CUSTOM CABLE & POWER SOLUTIONS TRYSTAR trystar.com

Generator DoCKInG StatIonS

Generator DoCKInG StatIonS Generator DOCKING STATIONS TRYSTAR Portable Power Cable Cam to cam cable extensions 2000V, 100A-400A rated to NEC table 400.5 (B) All portable power cable sold is highly flexible and UL & C-UL or CSA Listed

More information

DIRECTCONNECT SERVICE

DIRECTCONNECT SERVICE DIRECTCONNECT SERVICE PRE-ASSEMBLED: LEADS, GROUNDS AND STINGERS/WHIPS Save Time, Labor and Money Lead Stinger/Whip Stock Colors (Blue, Green, Red, Yellow) available Stocked genuine Lenco and Tweco Connectors

More information

BERTHOLD ELECTRIC GENERATOR CONNECTION CABINET

BERTHOLD ELECTRIC GENERATOR CONNECTION CABINET BERTHOLD ELECTRIC GENERATOR CONNECTION CABINET Berthold Electric Company s Generator Connection Cabinet provides a quick and convenient station to connect a portable generator to a facility s main service

More information

D-13. temporary / mobile power. for harsh & hazardous (classfied) locations. Construction Demolition Maintenance Turnarounds Shutdowns

D-13. temporary / mobile power. for harsh & hazardous (classfied) locations. Construction Demolition Maintenance Turnarounds Shutdowns for harsh & hazardous (classfied) locations Construction Demolition Maintenance Turnarounds Shutdowns D-13 temporary / mobile power Temporary power products are used on industrial and construction sites

More information

LEAD FREE FIREX. Interlock Armored Cables TECK90 and MC Industrial Cables. w w w. n e x a n s e n e r g y. c o m

LEAD FREE FIREX. Interlock Armored Cables TECK90 and MC Industrial Cables. w w w. n e x a n s e n e r g y. c o m FIREX Interlock Armored Cables TECK90 and MC Industrial Cables LEAD FREE O V E R 1 8 0 Y E A R S O F E X P E R I E N C E 866-663-9267 w w w. n e x a n s e n e r g y. c o m Interlock Armored Cables Introduction....2

More information

All work must conform to the National Electric Code, latest edition, and all other applicable codes and regulations.

All work must conform to the National Electric Code, latest edition, and all other applicable codes and regulations. DIVISION 16 ELECTRICAL SECTION 16100 - ELECTRICAL PART 1 - GENERAL SCOPE All electrical work as shown on the drawings and as necessary to provide a complete electrical system. Include primary service,

More information

Three-Phase Electric Power Distribution for Computer Data Centers

Three-Phase Electric Power Distribution for Computer Data Centers Three-hase Electric ower Distribution for Computer Data Centers WHITE AER E901 Geist January 008 Summary This paper will describe the characteristics of three-phase power and outline the advantages of

More information

How To Power A Power Supply On A Powerline From A Power Source To A Power Box

How To Power A Power Supply On A Powerline From A Power Source To A Power Box Power Base AI Power Base AI Application Guide Table of Contents Product Overview Our Philosophy On Electrical... 4 System Overview... 5 Power Base AI Statement of Line.... 6 Power Base AI Components...

More information

READ THIS MANUAL BEFORE PROCEEDING WITH THE INSTALLATION. FAILURE TO FOLLOW THE INSTALLATION INSTRUCTIONS MAY VOID YOUR WARRANTY!

READ THIS MANUAL BEFORE PROCEEDING WITH THE INSTALLATION. FAILURE TO FOLLOW THE INSTALLATION INSTRUCTIONS MAY VOID YOUR WARRANTY! READ THIS MANUAL BEFORE PROCEEDING WITH THE INSTALLATION. FAILURE TO FOLLOW THE INSTALLATION INSTRUCTIONS MAY VOID YOUR WARRANTY! The main power to any existing system must be disconnected prior to the

More information

IEC 309 INTERLOCKS NORTH AMERICAN

IEC 309 INTERLOCKS NORTH AMERICAN IEC 309 INTERLOCKS NORTH AMERICAN SWITCH VERSION with MCB (Circuit Breakers) 20, 30, 60 Amp NEMA 4X Watertight (IP67) Drawing A (See Drawing on Specification Page) 20, 30, 60 Amp Spashproof (IP44) Drawing

More information

SHORE POWER. Safely Connecting Ships to Shore SAFETY QUALITY INNOVATION VALUE CUSTOMER SERVICE

SHORE POWER. Safely Connecting Ships to Shore SAFETY QUALITY INNOVATION VALUE CUSTOMER SERVICE SHORE POWER Safely Connecting Ships to Shore SHIP-TO-SHORE SOLUTIONS FOR MILITARY & COMMERCIAL APPLICATIONS SAFETY QUALITY INNOVATION VALUE CUSTOMER SERVICE ESL Power Systems, Inc. ESL has established

More information

600V Power Cable 600V SOOW SOW

600V Power Cable 600V SOOW SOW 600V Power Cable Type SOOW UL/CSA 90 C 600V Part AWG No of Insulation Jacket Nominal Wieght/Mft Number Stranding conductors Thickness Thickness O.D. Nom. 18 2 SOOW 18 AWG 2.30 71 18 3 SOOW 16/.010 3.030

More information

DIVISION 26 - ELECTRICAL SECTION 26 05 20 CABLES FOR INSTRUMENTATION

DIVISION 26 - ELECTRICAL SECTION 26 05 20 CABLES FOR INSTRUMENTATION DIVISION 26 - ELECTRICAL PART 1 - GENERAL 1.01 SUMMARY A. Section Includes 1. Instrumentation Cables 1.02 SUBMITTALS A. Submit in accordance with requirements of Section 01 33 00. B. Product Data: Submit

More information

in widespread use with Simplex sister Company, Simplex Onsite, providing nationwide load bank rentals.

in widespread use with Simplex sister Company, Simplex Onsite, providing nationwide load bank rentals. 600KW - 1250KW Overview Integrated design, load module, trailer, reels, cam-lock style connections, digital control High capacity, 600-1250kw Dual voltage: 208-240/416-480vAC Digital load control, 5 kw

More information

Utility Distribution Systems

Utility Distribution Systems Utility Distribution Systems 6/2012 A0011037 1 WARRANTY This equipment is warranted to be free from defects in materials and workmanship, under normal use and service, for a period of 12 months from date

More information

TRAILER WIRING AND COMMUNICATION SYSTEMS Systèmes de Communication et Filage de Remorques Sistemas de Comunicación y Cableado para Caravanas

TRAILER WIRING AND COMMUNICATION SYSTEMS Systèmes de Communication et Filage de Remorques Sistemas de Comunicación y Cableado para Caravanas 162 Ultra-Pin Receptacle, Two Hole Mount Redundant ground through frame No rust, die-cast zinc Heavy bosses for extra rigidity Barrel slanted to drain moisture Mounting holes slotted for universal fit

More information

Electrical for Detached Garages: Updated Feb 19, 2016 for 2015 CE Code in force Jan. 1, 2016. Underground branch circuit feeding a detached garage:

Electrical for Detached Garages: Updated Feb 19, 2016 for 2015 CE Code in force Jan. 1, 2016. Underground branch circuit feeding a detached garage: Electrical for Detached Garages: Updated Feb 19, 2016 for 2015 CE Code in force Jan. 1, 2016 * Garage construction requires permits (electrical, building) * Permits must be applied for at the time. * Dial

More information

Electrical Grounding. Appendix C

Electrical Grounding. Appendix C Appendix C Electrical Grounding Low-Voltage Equipment Grounding The most frequently cited Office of Safety and Health Administration (OSHA) electrical violation is improper occupational grounding of equipment

More information

Rugged & Reliable Power Connections

Rugged & Reliable Power Connections Rugged & Reliable Power Connections featuring: DECONTACTOR TM Series Switch Rated Plugs & Receptacles High Amperage Plugs & Receptacles Multipin Connectors Benefit from Meltric Plugs, Receptacles, and

More information

ELECTRICAL CONNECTORS

ELECTRICAL CONNECTORS ELECTRICAL CONNECTORS 07-09 00-09 04-09 99-09 116 ELECTRICAL CONNECTORS LIGHT POWER MODULES WORKS WITH STANDARD & LED BULBS! WORKS WITH STANDARD & LED BULBS! CALL US TODAY FOR YOUR MODULITE VEHICLE APPLICATION

More information

Flexible cables for submersible products

Flexible cables for submersible products Flexible cables for submersible products Standards SUBCAB cables complies with the following general standards: IEC 6045 (general) IEC 608 class 5 (conductor) IEC 608-- CLAUSE 9 (oil resistant) IEC 608--

More information

Mini Power-Zone Unit Substation Product Description. Product Description. Features. Typical Applications

Mini Power-Zone Unit Substation Product Description. Product Description. Features. Typical Applications Product Description Product Description The Mini Power-Zone Unit Substation from Schneider Electric is a miniaturized version of our Power-Zone Unit Substation. Included are: Circuit Breaker Sealed Step-Down

More information

Mini USB and USB 2.0-IP67 Connector System

Mini USB and USB 2.0-IP67 Connector System Mini USB and USB 2.0-IP67 Connector System Section 12 Mini USB and USB 2.0-IP67 Connector System CONEC has added the Mini-USB connector. This Mini-USB IP67 receptacle and plug family, feature a bayonet

More information

Cabinets 101: Configuring A Network Or Server Cabinet

Cabinets 101: Configuring A Network Or Server Cabinet Cabinets 101: Configuring A Network Or Server Cabinet North, South and Central America White Paper May 2012 www.commscope.com Contents Background Information 3 What is a network or server cabinet? 3 What

More information

OVEN PARTS For Models:GMC305PDB07, GMC305PDQ07, GMC305PDT07, GMC305PDS07 (Black) (White) (Biscuit) (S.Steel)

OVEN PARTS For Models:GMC305PDB07, GMC305PDQ07, GMC305PDT07, GMC305PDS07 (Black) (White) (Biscuit) (S.Steel) OVEN PARTS 30" BUILT IN ELECTRIC COMBO SENSOR/SC (GOLD LINE) 7 03 Litho In U.S.A. (cre) 1 Part No. OVEN PARTS NOTE: The screws and nuts required to attach a part are listed immediately following that part.

More information

Magnum Mobile Generator MMG55 Specifications

Magnum Mobile Generator MMG55 Specifications Empowering Real People Magnum Mobile Generator MMG55 Specifications ENGINE John Deere PE5030TF270 - turbocharged, diesel engine o Prime - 72 hp @ 1800 rpm o Standby - 80 hp @ 1800 rpm o 4 cylinder o 3.0

More information

ELECTRICAL GUIDELINES FOR SINGLE-FAMILY HOME OWNERS:

ELECTRICAL GUIDELINES FOR SINGLE-FAMILY HOME OWNERS: ELECTRICAL GUIDELINES FOR SINGLE-FAMILY HOME OWNERS: Chapter 12 of the Burlington Code of ordinances allows owner occupants of single family homes to do their own wiring if they choose. If you choose to

More information

STABILOY BRAND FEEDER SOLUTIONS ASSISTED LIVING FACILITIES

STABILOY BRAND FEEDER SOLUTIONS ASSISTED LIVING FACILITIES STABILOY BRAND FEEDER SOLUTIONS ASSISTED LIVING FACILITIES Introduction General Cable understands that assisted living facilities require complex building designs that must address a wide range of systems

More information

2012 CATALOG AEROSPACE VVIRE & CABLE INC. aerospacewire.com

2012 CATALOG AEROSPACE VVIRE & CABLE INC. aerospacewire.com * 2012 CATALOG AEROSPACE VVIRE & CABLE INC. A VV aerospacewire.com W e p r o u d l y m a n u f a c t u r e h i - t e m p w i r e & c a b l e. PLENUM CABLE. INDUSTRIAL CABLE. TRAY CABLE. MILITARY WIRE.

More information

450-750 VOLTS - Copper conductor PVC insulated SSA 1320, IEC 60227 & BS 6004 HO 7V - U With Solid Conductor - TYPE 60227 IEC 01. Insulation Thickness

450-750 VOLTS - Copper conductor PVC insulated SSA 1320, IEC 60227 & BS 6004 HO 7V - U With Solid Conductor - TYPE 60227 IEC 01. Insulation Thickness 450 50 VOLTS Copper conductor PVC insulated SSA 320, IEC 6022 & BS 6004 HO V U With Solid TYPE 6022 IEC 0 For internal wiring equipment rated voltage up to 000 V AC and up to 50 V to earth. Catalogue Number

More information

SECTION 26 09 26 LOW VOLTAGE LIGHTING CONTROLS

SECTION 26 09 26 LOW VOLTAGE LIGHTING CONTROLS SECTION 26 09 26 LOW VOLTAGE LIGHTING CONTROLS PART 1 - GENERAL 1.01 RELATED DOCUMENTS: A. The Conditions of the Contract and applicable requirements of Division 1, "General Requirements", and Section

More information

Flygt flexible cables

Flygt flexible cables Flygt flexible cables Contents Standards General SUBCAB 4 Screened SUBCAB 6 Rubber cable type: NSSHÖU-J 7 Screened rubber cable type: NSSHÖU../E + ST 8 FGB screened rubber cable 9 PUR control cable 0 HCR

More information

KNOW YOUR OPTIONS: 230 KV POWER CABLES

KNOW YOUR OPTIONS: 230 KV POWER CABLES KNOW YOUR OPTIONS: 230 KV POWER CABLES 71 CONDUCTOR MATERIAL AND SIZE Conductor material is a matter of both customer preference and required current carrying capacity At 230 kv, copper is most common

More information

Submit shop drawings for equipment provided under this section Shop drawings shall indicate:

Submit shop drawings for equipment provided under this section Shop drawings shall indicate: Section 16435 - SWITCHBOARDS Introduction Part 1 - General Reference The work under this section is subject to requirements of the Contract Documents including the General Conditions, Supplementary Conditions,

More information

PT-6000 Power Tower INSTALLATION MANUAL SPECIFICATIONS

PT-6000 Power Tower INSTALLATION MANUAL SPECIFICATIONS PT-6000 Power Tower INSTALLATION MANUAL 10.5 9.75 12 22.75 10.75 MAXIMUM SOIL HEIGHT: DO NOT ALLOW FILL TO EXCEED THIS LEVEL! 11.5 4 4 13 Optional PT-BASE for new installations or when previous 2000/6000

More information

Cluster Box Units. (CBU s) 3300 Series CBU Door Sizes. Fully Integrated Parcel Lockers CLUSTER BOX UNITS FRONT LOADING. continued on pages 7-11

Cluster Box Units. (CBU s) 3300 Series CBU Door Sizes. Fully Integrated Parcel Lockers CLUSTER BOX UNITS FRONT LOADING. continued on pages 7-11 Cluster Box Units (CBU s) continued on pages 7-11 CLUSTER BOX UNITS FRONT LOADING Made of heavy duty aluminum and stainless steel hardware, Salsbury 3300 series U.S.P.S. approved Cluster Box Units (CBU

More information

The MC Cable Revolution is Gaining Ground REMKE

The MC Cable Revolution is Gaining Ground REMKE The MC Cable Revolution is Gaining Ground June 2014 MC Cable Installation Continues to Improve with Advances in Materials and Fittings As the use of Metal Clad Cable grows, contractors are demanding better

More information

* Please visit the product pages on our website for the most up-to-date product information. Con-X Molded Cable Assembly Checklist...

* Please visit the product pages on our website for the most up-to-date product information. Con-X Molded Cable Assembly Checklist... TABLE OF CONTENTS Custom Molded Cable Assemblies and Connectors..........................2 Capabilities.....................................................................3 Standard Connector Products.......................................................4

More information

Section 5 161 kv Power Cables

Section 5 161 kv Power Cables Know Your Options: 161 kv Power Cable 61 material and size material is a matter of both customer preference and required current carrying capacity Copper conductor common for larger loads When both copper

More information

Mini Power-Zone Unit Substation

Mini Power-Zone Unit Substation Catalog 7440CT0901 2009 Class 7440 CONTENTS Description............................................. Page Product Description...........................................2 General Information...........................................3

More information

AUTOMATIC BEST BATTERY SELECTOR INSTALLATION & OPERATION BBS-1600 BBS-1600E

AUTOMATIC BEST BATTERY SELECTOR INSTALLATION & OPERATION BBS-1600 BBS-1600E AUTOMATIC BEST BATTERY SELECTOR INSTALLATION & OPERATION BBS-1600 BBS-1600E SENS part no: 101314 Document revision: F DCN No. 106811 Date 8/3/15 1840 Industrial Circle Longmont, CO 80501 Fax: (303) 678-7504

More information

Heating Cable. Construction

Heating Cable. Construction Mineral Insulated High Temperature A C Constant Wattage Series Resistance Heating Cable Sets Process Temperature Maintenance to F (593 C) Maximum Exposure Temperature 4 F (76 C) (Power Off) Corrosion Resistant

More information

STABILOY BRAND FeeDeR SOLuTIONS

STABILOY BRAND FeeDeR SOLuTIONS STABILOY BRAND Feeder Solutions DATA CENTER Introduction General Cable understands that data centers depend heavily on a steady, reliable and scalable source of power. That is why our STABILOY Brand aluminum

More information

UNDERSTANDING. C&M Corporation 51 South Walnut Street, Wauregan, CT 06387 Phone: 860.774.4812 Fax: 860.774.7330 www.cmcorporation.

UNDERSTANDING. C&M Corporation 51 South Walnut Street, Wauregan, CT 06387 Phone: 860.774.4812 Fax: 860.774.7330 www.cmcorporation. UNDERSTANDING UNDERSTANDING NFPA 79 By Ned Lloyd and Mike Levesque NFPA-79 is the electrical standard that has been developed by the National Fire Protection Association (NFPA) and is intended to minimize

More information

OVEN PARTS For Models:GSC308PJB05, GSC308PJQ05, GSC308PJT05, GSC308PJS05 (Black) (White) (Biscuit) (Black Stainless)

OVEN PARTS For Models:GSC308PJB05, GSC308PJQ05, GSC308PJT05, GSC308PJS05 (Black) (White) (Biscuit) (Black Stainless) OVEN PARTS 30" BUILT IN ELECTRIC COMBO SENSOR/SC (GOLD LINE) 3 05 Litho In U.S.A. (cre) 1 Part No. Rev.A OVEN PARTS 1 Literature Parts 4455994 Installation Instructions Use & Care Guide 8300346 Microwave

More information

STABILOY BRAND FeeDeR SOLuTIONS

STABILOY BRAND FeeDeR SOLuTIONS STABILOY BRAND Feeder Solutions DATA CENTER Introduction General Cable understands that data centers depend heavily on a steady, reliable and scalable source of power. That is why our STABILOY Brand aluminum

More information

INDUSTRY WIDE LABOR-MANAGEMENT SAFETY COMMITTEE SAFETY BULLETIN #23

INDUSTRY WIDE LABOR-MANAGEMENT SAFETY COMMITTEE SAFETY BULLETIN #23 INDUSTRY WIDE LABOR-MANAGEMENT SAFETY COMMITTEE SAFETY BULLETIN #23 GUIDELINES FOR WORKING WITH PORTABLE POWER DISTRIBUTION SYSTEMS AND OTHER ELECTRICAL EQUIPMENT "ADDENDUM C" WORKING WITH 480 VOLT SYSTEMS

More information

KNOW YOUR OPTIONS: 69 KV XLPE POWER CABLE

KNOW YOUR OPTIONS: 69 KV XLPE POWER CABLE Know Your Options: 69 kv XLPE Power Cable 3 material and size material is a matter of both customer preference and required current carrying capacity Copper conductor common for larger loads When both

More information

Cable and Cord Reels. Section R. Cable and Cord Reels Index. Index

Cable and Cord Reels. Section R. Cable and Cord Reels Index. Index Section R Index Product Page Number and R-2 3 Weatherproof Cable and Static Discharge Reels R-4 R-5 R-6 Index www.hubbell-wiring.com and and Hubbell Electric Cord and Cable Reels Hubbell Wiring Device

More information

NEC 2014 Code Changes

NEC 2014 Code Changes NEC 2014 Code Changes Articles 400-408.55 CHANGES FROM 2011 TO 2014 CODE ARE IN RED Chapter 4 Equipment for General Use ARTICLE 400 Flexible Cords and Cables 400.4 Types Flexible cords and flexible cables

More information

HPS Universal. Single and Three Phase Potted. Buck-Boost Transformers. Buck-Boost Applications & Standard Specification... 80

HPS Universal. Single and Three Phase Potted. Buck-Boost Transformers. Buck-Boost Applications & Standard Specification... 80 Buck-Boost Transformers Single and Three Phase Potted Buck-Boost Transformers Buck-Boost Applications & Standard Specification... 80 Selecting Buck-Boost Transformers... 81 Single Phase Selection Tables...

More information

SECTION 25110 TELECOMMUNICATION ROOMS

SECTION 25110 TELECOMMUNICATION ROOMS PART 1 - GENERAL 1.1 SUMMARY A. SCOPE SECTION 25110 TELECOMMUNICATION ROOMS 1. This section includes the minimum installation requirements for equipment and cabling infrastructure in Telecommunication

More information

POLARIS INSUL-TAP CONNECTORS FOR TWO WIRES & IN-LINE SPLICERS/REDUCERS

POLARIS INSUL-TAP CONNECTORS FOR TWO WIRES & IN-LINE SPLICERS/REDUCERS INSUL-TAP CONNECTORS FOR TWO S & IN-LINE SPLICERS/REDUCERS IT SERIES 1 2 3 4 Insul-Tap connectors are suitable for connecting two wires. For sizes 3/0 AWG and smaller, they are available in two styles

More information

Thermwire. Selection Guide. Freeze Protection Heating Cable. Thermwire -Wrap. Pre-Assembled. Thermwire-Comp. Thermwire-Melt.

Thermwire. Selection Guide. Freeze Protection Heating Cable. Thermwire -Wrap. Pre-Assembled. Thermwire-Comp. Thermwire-Melt. Thermwire Freeze Protection Heating Cable Selection Guide Pipe Freeze Protection Heating Cable Pre-Assembled Pipe Freeze Protection Heating Cable with Attached Cord & Plug Thermwire-Comp Refrigeration

More information

Doc Ref: 2015.06.01.002. 602.783.1112 baselayer.com 2015 BASELAYER TECHNOLOGY, LLC

Doc Ref: 2015.06.01.002. 602.783.1112 baselayer.com 2015 BASELAYER TECHNOLOGY, LLC TM 602.783.1112 baselayer.com 2015 BASELAYER TECHNOLOGY, LLC TM D400E Data Module (60Hz) The EDGE D400E is designed to meet high power density requirements for both the HPC and Web Scale environments while

More information

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS PLEASE READ COMPLETE INSTRUCTIONS BEFORE YOU BEGIN LEAVE INSTALLATION INSTRUCTIONS AND USER'S GUIDE WITH OWNER ALL ELECTRIC WIRING AND PLUMBING MUST BE DONE

More information

CIR. Index. Gexol. Standard CIR UL Listed Type TC-ER. Crush and Impact Resistant Without External Armoring. Arctic CIR UL Listed Type TC-ER-HL*

CIR. Index. Gexol. Standard CIR UL Listed Type TC-ER. Crush and Impact Resistant Without External Armoring. Arctic CIR UL Listed Type TC-ER-HL* Gexol CIR Crush and Impact Resistant Without External Armoring Passes the same stringent crush and impact testing required by UL 2225 for Type MC-HL n Available in Standard and Arctic Grade Jackets n Highly

More information

VS CONTROL PACK INSTALLATION INSTRUCTIONS

VS CONTROL PACK INSTALLATION INSTRUCTIONS VS CONTROL PACK INSTALLATION INSTRUCTIONS Hot Tub Works www.hottubworks.com 1-800-770-0292 CustomerCare@HotTubWorks.com Congratulations! You have purchased and are about to install in your spa, the most

More information

East Central College 14434.03 HANSEN HALL LEVEL 300/400 RENOVATIONS PACKAGE

East Central College 14434.03 HANSEN HALL LEVEL 300/400 RENOVATIONS PACKAGE SECTION 260519 - BUILDING WIRE AND CABLE PART 1 - GENERAL 1.1 WORK INCLUDES A. Base and Alternate Bids: 1. Contractor Provide: a. Building wire and cable as shown on drawings or specified including feeders,

More information

Instrumentation Cable...14-17. Power Cable...2-11. Assembly Solutions...32

Instrumentation Cable...14-17. Power Cable...2-11. Assembly Solutions...32 Severe Cold Durability Exceeds CSA Cold Bend / Cold Impact (-0 C/-35 C) Drilling Mud Resistant Flame Retardant Certified to IEC 9-3 (33-3A) and IEEE 580 Oil Resistant Assemblies...3-33 Ester Based Mud

More information

Pump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling

Pump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling Pump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling 250_P1 R10/7/2015 Copyright 2015 Liberty Pumps Inc. All rights reserved. Specifications subject to change without notice.

More information

Application Bulletin 103 - NEC Reference Guide for SolarBridge-Enabled AC Module Installers

Application Bulletin 103 - NEC Reference Guide for SolarBridge-Enabled AC Module Installers 9229 Waterford Centre Dr. Bldg C, Suite 110 Austin, Tx 78758 Application Bulletin 103 - NEC Reference Guide for SolarBridge-Enabled AC Module Installers Current Version: 13 AC Modules are a new product

More information

PART 1 - INTRODUCTION...

PART 1 - INTRODUCTION... Table of Contents PART 1 - INTRODUCTION... 3 1.1 General... 3 1.2 Sensor Features... 3 1.3 Sensor Specifications (CDE-45P)... 4 Figure 1-1 CDE-45P Sensor Dimensions (standard, convertible style)... 4 PART

More information

The National Armored Cable Manufacturers Association Presents. Installation Standard for Types AC and MC Cables

The National Armored Cable Manufacturers Association Presents. Installation Standard for Types AC and MC Cables The National Armored Cable Manufacturers Association Presents Installation Standard for Types AC and MC Cables An ANSI Standard Original document jointly produced by NECA and NACMA as Standard for Installing

More information

Power Outlet Panels. Product Guide

Power Outlet Panels. Product Guide Product Guide Construction and Recreational Vehicle (RV) Power Outlet Panels Vehicle Power (RV) Power Outlet Panels Power Outlet Panels Construction and RV Power Outlet Panels Product Description...1 Application

More information

Standard Buccaneer - Ethernet

Standard Buccaneer - Ethernet IP6 rated compliant PUR jacket on cable Shielded system shielded coupler Shroud on RJ45 Screw coupling Rewireable flex connector PCB mounted panel connector IDC termination panel connector Earth lead version

More information

Metallic and Non-Metallic Air Conditioning Disconnects. A Complete Family of. Disconnects with Exclusive Time Saving Features

Metallic and Non-Metallic Air Conditioning Disconnects. A Complete Family of. Disconnects with Exclusive Time Saving Features Metallic and Non-Metallic Air Conditioning Disconnects A Complete Family of Disconnects with Exclusive Time Saving Features Enclosed Molded Case Disconnect Switch Not-Fusible The preferred molded case

More information

ETHERLINE Ethernet Cable, Connectors & Tools

ETHERLINE Ethernet Cable, Connectors & Tools Ethernet Cable, ors & Tools 2 Pair 242 4 Pair 249 Industrial Ethernet ors & Tools 256 Ethernet Cable, ors & Tools ETHERNET CABLE, CONNECTORS & TOOLS Quick Select Chart 240 2 Pair 2 Pair: CAT.5/5e; Stationary

More information

Roof Top Air Conditioner INSTALLATION AND OPERATING INSTRUCTIONS

Roof Top Air Conditioner INSTALLATION AND OPERATING INSTRUCTIONS Roof Top Air Conditioner INSTALLATION AND OPERATING INSTRUCTIONS Ducted System RECORD THIS UNIT INFORMATION FOR FUTURE REFERENCE: Model Number: Serial Number: Date Purchased: This manual must be read and

More information

USA: 866.LAWSON4U (866.529.7664) Canada: 800.563.1717 lawsonproducts.com. Electrical Industrial and Fleet Solutions

USA: 866.LAWSON4U (866.529.7664) Canada: 800.563.1717 lawsonproducts.com. Electrical Industrial and Fleet Solutions USA: 866.LAWSON4U (866.529.7664) Canada: 800.563.1717 lawsonproducts.com Electrical Industrial and Fleet Solutions Lawson's ELECTRICAL SOLUTIONS Electrical Wire Low voltage (60V) and high voltage (300/600V)

More information

Intersection Preassembled 19-inch Rack

Intersection Preassembled 19-inch Rack Intersection Preassembled 19-inch Rack The intersection preassembled 19-inch rack comes fully assembled, wired and ready to be installed in a server rack. The rack provides communications, power conversion

More information

I nstallation. M100Q Series Proportional Actuator with R81Q Controller Board for Thermistor Sensor Applications. Tools Needed.

I nstallation. M100Q Series Proportional Actuator with R81Q Controller Board for Thermistor Sensor Applications. Tools Needed. FANs 268.1, 1628.3 Installation Bulletin M100Q Issue Date 1099 M100Q Series Proportional Actuator with R81Q Controller Board for Thermistor Sensor Applications I nstallation Parts Included M110QGA-1 and

More information

12VDC MAGNETIC LED DIMMABLE POWER SUPPLIES SPEC SHEET DIGEST

12VDC MAGNETIC LED DIMMABLE POWER SUPPLIES SPEC SHEET DIGEST 12VDC MAGNETIC ED DIMMABE POER SUPPIES SPEC SEET DIGEST TM-30-DIM TM-50-DIM T-60-DIM TM100-DIM TM200-DIM TM300-DIM iring Diagram for TM-50-DIM and TM-100-DIM ED 12VDC MAGNETIC DIMMABE 30 POER SUPPY Smallest

More information

42U/45U 28" Wide Rack Installation & Service Guide

42U/45U 28 Wide Rack Installation & Service Guide 42U/45U 28" Wide Rack Installation & Service Guide 96-00171-005 Rev B Important Information Information in this document is subject to change without notice and does not represent a commitment on the part

More information

Cable-Gard Static Discharge Reels

Cable-Gard Static Discharge Reels Cable-Gard Static Discharge Reels Applications: Static discharge reels are used for grounding portable machines and equipment in hazardous areas, such as fuel transfer trucks, grain elevators, dockside

More information

Standards Affecting a Premise T-1 Installation

Standards Affecting a Premise T-1 Installation Standards Affecting a Premise T-1 Installation The T-carrier system originated many years ago as a technology developed by AT&T. The intended use of the scheme was to increase the voice channel capacity

More information

Quick Reference Guide Euro Style Terminal Blocks

Quick Reference Guide Euro Style Terminal Blocks Quick Reference Guide Euro Style terminal block connectors feature various wire termination methods including rising cage clamp, wire protector, spring, IDC and crimp snap. The design of terminal block

More information

Electrical Code Regulation

Electrical Code Regulation Electrical Code Regulation St. Clair County has adopted the 2005 National Electrical Code in its entirety for the unincorporated areas of the county and all communities that have contracted with the county

More information

TELE-FONIKA CABLE AMERICAS

TELE-FONIKA CABLE AMERICAS TELE-FONIKA CABLE AMERICAS TELE-FONIKA CABLE AMERICAS (TF KABLE) is a US firm with corporate offices and main facility located in Bolingbrook, IL and is a wholly owned subsidiary of Tele-Fonika Kable SA.

More information

picomax The Pluggable Connection System

picomax The Pluggable Connection System picomax The Pluggable Connection System TECHNOLOGY THIS SPECIALIZED CAN T MEET ALL REQUIREMENTS. YES IT CAN. CONTENTS picomax Pin spacing: 3. mm/0.138 in;.0 mm/0.197 in; 7. mm/0.29 in Versatile Pluggable

More information

VIPERFLEX ELECTRIC CABLE

VIPERFLEX ELECTRIC CABLE VIPERFLEX Flexible Low Voltage Electric Cable - 0.6/1kV (Rubber insulated) H07 RN-F & H07 BN-F Single Core 2-Core 2-Core and Earth 3-Core and Earth 4-Core and Earth Multi-Core and Earth H07 RCN-F & H07

More information

STREETLIGHT SYSTEM GROUNDING AND BONDING

STREETLIGHT SYSTEM GROUNDING AND BONDING Page: 1 of 8 STREETLIGHT SYSTEM GROUNDING AND BONDING 1. Scope This Construction Standard covers the grounding and bonding requirements for single phase streetlight systems served by the Looped Radial

More information

SOHOline and SOHO Slimline The SOHOline and SOHO Slimline offer a modular, sturdy and compact design

SOHOline and SOHO Slimline The SOHOline and SOHO Slimline offer a modular, sturdy and compact design SOHOline and SOHO Slimline The SOHOline and SOHO Slimline offer a modular, sturdy and compact design Ideal installation for; Offices Branch Offices Schools Computer Aided Classes Government Offices Hotels

More information

The Contractor shall furnish and install all shielded power cable suitable for use on this project.

The Contractor shall furnish and install all shielded power cable suitable for use on this project. Section 16122 PRIMARY POWER CABLES PART 1 GENERAL: WORK INCLUDED The Contractor shall furnish and install all shielded power cable suitable for use on this project. RELATED WORK Section 16020: Tests SUBMITTALS

More information

Extension Cord Safety Policy

Extension Cord Safety Policy NATIONAL HIGH MAGNETIC FIELD LABORATORY Operated by Florida State University, University of Florida, Los Alamos National Laboratory Florida State University, 1800 East Paul Dirac Drive, Tallahassee, Florida

More information

AMPSEAL* Automotive Plug Connector and Header Assembly

AMPSEAL* Automotive Plug Connector and Header Assembly AMPSEAL* Automotive Plug Connector and Header Assembly Application Specification 24 SEP 97 Rev E All dimensions are given in millimeters unless otherwise specified. All dimensional tolerances are +0.2

More information

ELECTRICAL SERVICE REQUIREMENTS FOR MOBILE HOME DEVELOPMENTS

ELECTRICAL SERVICE REQUIREMENTS FOR MOBILE HOME DEVELOPMENTS Prepared by: ABB1 ELECTRICAL SERVICE REQUIREMENTS FOR MOBILE HOME DEVELOPMENTS 052521 Asset Type: Electric Metering Function: Construction Issued by: Quoc Hoang (QxH1) Date: 07-01-16 Rev. #06: This document

More information

2011/2008/2005 NATIONAL ELECTRICAL CODE SOLAR PV CODE COMPLIANCE REFERENCE

2011/2008/2005 NATIONAL ELECTRICAL CODE SOLAR PV CODE COMPLIANCE REFERENCE 2011/2008/2005 NATIONAL ELECTRICAL CODE SOLAR PV CODE COMPLIANCE REFERENCE PAGE 1 OF 5 This Reference provides a very comprehensive list of aspects of a solar PV installation that could be reviewed, clarifying

More information

Lighting Packages. 230 VAC Fluorescent Enclosure Light:

Lighting Packages. 230 VAC Fluorescent Enclosure Light: Spec-00581 H763.422.2211 763.422.2600 Electrical Lighting Packages Electrical Lighting Packages PANELITE Enclosure Lights Overview FEATURES Slim profile allows light to be tucked up out of the way for

More information

TRUCK BOXES - UNDERBODY BOXES

TRUCK BOXES - UNDERBODY BOXES TRUCK BOXES - UNDERBODY BOXES BLACK, STAINLESS STEEL T-HANDLE LATCH 14-gauge steel box, 12-gauge steel door (12-gauge steel box, 12-gauge steel door on 66" toolboxes). Recessed/beveled door. Rain channel

More information

OASIS-PLUS 120V READ ALL INSTRUCTIONS BEFORE OPERATING READ ALL INSTRUCTIONS BEFORE OPERATING OZONE IS A POWERFUL OXIDIZER AND MUST BE USED WITH CARE

OASIS-PLUS 120V READ ALL INSTRUCTIONS BEFORE OPERATING READ ALL INSTRUCTIONS BEFORE OPERATING OZONE IS A POWERFUL OXIDIZER AND MUST BE USED WITH CARE OASIS-PLUS 120V INFORMATION & OPERATING INSTRUCTIONS READ ALL INSTRUCTIONS BEFORE OPERATING READ ALL INSTRUCTIONS BEFORE OPERATING OZONE IS A POWERFUL OXIDIZER AND MUST BE USED WITH CARE 56041852 WARNING:

More information

MTE SERIES RLW. World REACTORS USER MANUAL PART NO. INSTR 030 REL. 090930. 2009 MTE Corporation

MTE SERIES RLW. World REACTORS USER MANUAL PART NO. INSTR 030 REL. 090930. 2009 MTE Corporation MTE SERIES RLW World REACTORS USER MANUAL PART NO. INSTR 030 REL. 090930 2009 MTE Corporation IMPORTANT USER INFORMATION NOTICE MTE Series RLW reactors are components designed to improve the reliability

More information

Requirements for Electrical Installations

Requirements for Electrical Installations ARTICLE 110 Requirements for Electrical Installations INTRODUCTION TO ARTICLE 110 REQUIREMENTS FOR ELECTRICAL INSTALLATIONS Article 110 sets the stage for how you ll implement the rest of the NEC. This

More information

Industrial Cable Solutions for Variable Frequency Drives

Industrial Cable Solutions for Variable Frequency Drives Industrial Cable Solutions for Variable Frequency Drives Tough challenges call for innovative solutions, and General Cable is your worldwide source for new products and a wide range of industry-leading

More information

INSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate Locks

INSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate Locks Securitron Magnalock Corp. www.securitron.com ASSA ABLOY, the global leader Tel 800.624.5625 techsupport@securitron.com in door opening solutions INSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate

More information

ELECTRIC METERING COMMERCIAL & INDUSTRIAL

ELECTRIC METERING COMMERCIAL & INDUSTRIAL ELECTRIC METERING COMMERCIAL & 1.0 INDEX 1.0 INDEX 2.0 SCOPE 3.0 GENERAL REQUIREMENTS 4.0 METER LOCATIONS 5.0 UNDERGROUND TERMINATIONS 6.0 METERING TRANSFORMER ENCLOSURES 7.0 SINGLE CUSTOMER METER INSTALLATIONS

More information

Arktite Heavy Duty Circuit Breaking Plugs and Receptacles

Arktite Heavy Duty Circuit Breaking Plugs and Receptacles 1312-1313.qxp 12/16/2013 7:04 PM Page 1312 Arktite Heavy Duty Circuit Breaking Plugs and Receptacles Industrial Heavy Duty Non-hazardous Areas Features: Arktite circuit breaking plugs and receptacles are

More information

E2 Series Electric Furnaces

E2 Series Electric Furnaces E2 Series Electric Furnaces Service Manual Table of Contents Electrical Requirements... 10 Codes, Specifications Requirements... 10 Connection Supply Service Wires... 10 Furnace Sequence of Operation...

More information

2a. IEM Indoor Metal Clad Medium Voltage Switchgear 15KV 16346-1. 2a. Section 16346 INDOOR METAL CLAD MEDIUM VOLTAGE SWTICHGEAR (Std.

2a. IEM Indoor Metal Clad Medium Voltage Switchgear 15KV 16346-1. 2a. Section 16346 INDOOR METAL CLAD MEDIUM VOLTAGE SWTICHGEAR (Std. 2a. IEM Indoor Metal Clad Medium Voltage Switchgear 15KV 16346-1 2a. Section 16346 INDOOR METAL CLAD MEDIUM VOLTAGE SWTICHGEAR (Std. Relays) Part 1 General 1.1 CONDITIONS AND REQUIREMENTS: A. Refer to

More information

Gexol. Gexol. The Global Cable Solutions Company. Designed for safe, reliable performance in the harshest oil and gas operating environments

Gexol. Gexol. The Global Cable Solutions Company. Designed for safe, reliable performance in the harshest oil and gas operating environments Gexol Gexol World Class World Class Designed for safe, reliable performance in the harshest oil and gas operating environments Power Control Instrument VFD The Global Cable Solutions Company Gexol World

More information