Canyon State Property Inspections 3114 South 98th Street Mesa, AZ (888)

Size: px
Start display at page:

Download "Canyon State Property Inspections 3114 South 98th Street Mesa, AZ 85212 1 (888) 800-2774"

Transcription

1 Page 1 of 22 Canyon State Property Inspections 3114 South 98th Street Mesa, AZ (888) Printed Friday, March 17, 2006 Inspected By: Steven Callahan Referral Information Realtor Your Client Information: Record Number SC Buyer, Home 123 Your New Home Street Home Town, AZ Inspected 3/3/06 10:00 AM Weather Conditions day of Inspection Partly Cloudy Measurable Precipitation in past 48 Hours No Approx. Temperature Degrees Accompanied Inspector Buyer, Buyer's Agent Occupancy Vacant Building Type Site Built Building Position West Approximate Age of Structure At the front of the building. Position is an approximation and for identification purposes of this report only. Type of Addition/Conversion None

2 Page 2 of 22 Opinions of Inspection Report Definitions Additional Notes : System or component is functioning the way it was intended. Age of item and normal wear and tear may not be a concluding factor to enter in this report. Safety Concerns: Any condition observed that may be potentially dangerous, harmful, and unstable or a heath concern. Recommend licensed contractor or competent service person performs repairs, adjustments and/or replacement. Major Defect: Items may be costly to repair. Components, systems or areas have failed or is at the end its useful life. Recommend licensed contractor or competent service person performs repairs, adjustments and/or replacement. Service/Repair: In most cases a knowledgeable homeowner or handyman can perform this work and in some cases a licensed contractor or competent service person may be needed to perform repairs, adjustments and/or replacement. Deferred maintenance may not be appropriate. Description of Services, Summary Report You have contracted for us to perform a general home inspection in accordance with the Arizona Standards of Professional Practice, a copy of which is included with this report. It is distinct from a specialist inspection, which can be costly, take several days to complete, involves the use of specialized instruments, the dismantling of equipment, video-scanning, destructive testing, and laboratory analysis. By contrast, this general inspection is completed on-site, at a fraction of the cost and within a few hours. Consequently, the general inspection and its report are not technically exhaustive and will not identify concealed conditions or latent defects. Our purpose is to identify defects or adverse conditions that could result in injury or lead to costs that would significantly affect your evaluation of the property, and to alert you to the need for an evaluation by qualified professionals. We observe readily accessible installed systems, or components, and report on their condition. This does not mean these systems and components are ideal but that they either function or meet a reasonable standard at the time of the inspection. We do take into consideration when a house was built and allow for the predictable deterioration that would occur through time, such as the cracks that appear in concrete and in the plaster around windows and doors, scuffed walls or woodwork, worn or squeaky floors, and stiff or stuck windows. Therefore, we tend to ignore insignificant and predictable defects, and do not annotate them, and particularly those that would be apparent to the average person or to someone without any construction experience. We also do not evaluate for seismic construction. A house and its components are complicated, and because of this and the limitations of an on-site report, we offer unlimited consultation and encourage you to ask questions. In fact, we encourage candid and forthright communication between all parties, because we believe that it is the only way to avoid stressful disputes and costly litigation. Remember, we only summarized the report on-site and it is essential that you read all of it, and that any recommendations that we make for service or evaluation by qualified professionals should be completed and documented before the close of escrow, because additional defects could be revealed by a specialist, or some upgrades recommended that could affect your evaluation of the property, and our service does not include any form of warranty or guarantee. We do not evaluate automatic sprinkler systems, and recommend that you have the sellers demonstrate the system before the close of escrow, and indicate any seasonal changes that they may make in the program. This Summary Report is intended to provide a convenient and cursory preview of the conditions and components that we have identified within our report as needing service. It is obviously not comprehensive, and should not be used as a substitute for reading the entire report, nor is it an implied endorsement of the condition of components or features that may not appear in this summary. Also, the service recommendations that we make in this summary and throughout the report should be completed before the close of escrow by qualified professionals, who may well identify additional defects or recommend some upgrades that could affect your evaluation of the property. This report is the exclusive property of the Inspection Company and the client whose name appears herewith, and its use by any unauthorized persons is prohibited.

3 Page 3 of 22 Inspection Summary Canyon State Property Inspections 3114 South 98th Street Mesa, AZ (888) FUEL SYSTEM FUEL SYSTEM Safety Concern There is a gas odor and leak detected at the pool heater at the time of the inspection. The gas company needs to be notified immediately for further evaluations and repairs. It is advised that the local Gas Company light all pilots for ALL gas appliances prior to the close of this transaction. The reason for this recommendation is that the Gas Company routinely performs safety tests on gas fixtures. These tests can reveal problems, which may not be discovered in the course of a limited visual property inspection. Tests for gas leaks or pipe sizing are not performed. The presence or condition of underground fuel storage tanks is not part of this inspection. LIGHTS & OUTLETS Electrical Receptacles The southwest porch outlet receptacle is broken/damaged. This is an electrical shock hazard. Recommend having a handyman replace the outlet receptacle. PARKING STRUCTURE Interior Ceiling There are 2 vent holes in the garage ceiling compromising its fire integrity. The vents needs to be removed and the ceiling needs to be properly patched with ½ inch gypsum board (fire rated 5/8 inch drywall) or 16 gage ducting needs to be properly installed for fire integrity. Recommend further evaluation and repairs by a competent contractor. There is water stains in the ceiling. This is an indication of a roof leak in that general area. Recommend further evaluation and repairs by a competent licensed contractor. Summary: Page 1 of 5 Canyon State Property Inspections

4 Page 4 of 22 ROOF MAIN ROOF The roll roofing is at or past its end of life. Evidence of patch work. Major Defect Debris on the roof should be removed. The debris restricts the flow of water off the roof and creates areas for potential standing water. Roof Covering There are areas of cut/torn/weathered and damaged roll roofing. The roll roofing should be replaced to prevent water damage/dry rot to the roof sheathing and structure. Recommend further evaluation and repairs by a competent licensed roofing contractor. Summary: Page 2 of 5 Canyon State Property Inspections

5 Page 5 of 22 EXTERIOR Other Exterior Doors Major Defect The garage service door is damage along the doorframe. The damage appears to be caused by a wood-destroying insect. Recommend having written confirmation by a licensed pest/termite inspector and treatment to prevent further/continued damage. Recommend repairing/replacing any/all structural issue damage. Refinish the doorframe and wall surfaces to like the surrounding area. A competent handyman/person can be used to complete this repair. W. HEATER WATER HEATER The water heater is making a popping sound caused by loose sediment in the tank. This sediment will reduce the heating capacity of the unit over time. The water heater has excessive rust flakes in the burner compartment. This is and indication that the unit is at its end of life. Recommend replacing the unit. Recommend further evaluation and repairs by a competent water heater service technician/plumber contractor. TPR- (Temperature Pressure Release valves) are recommended to be tested yearly by the property owner. Inspector performing test of valves is outside the scope of this inspection. Function of hot water circulating pumps is not verified. FIREPLACES AND WOOD STOVES FIREPLACES AND WOOD STOVES The master bedroom and living room gas fireplace did not function at the time of the inspection. The igniter did not spark to light the gas pilot. Recommend further evaluation and repairs by a certified gas fireplace technician. Service/Repair EXTERIOR Soffit\Fascia\Trim\Eaves The garage door wood trim boards have areas of weathering that need to be painted. Patio Doors The sliding glass door wheels do not properly slide. The wheels have a very difficult time move. Recommend repairing or replacing the wheels for proper operation/movement. A competent handyman/person can be used to complete this repair. Window Screens Weathered screens Missing screen(s) Summary: Page 3 of 5 Canyon State Property Inspections

6 Page 6 of 22 GROUNDS Retaining Wall Service/Repair The east retaining wall has areas of effloresces, chipping and peeling paint which appears to be cause by the plant/flower boxes behind the wall. If the boxes are going to be continued to be used for plants, which will require regular watering it is recommended that the boxes, which hold the plants, be sealed with a water sealant to protect the wall from deterioration. LIGHTS & OUTLETS Switches and Light Fixtures Recommend replacing bulbs to verify function of light fixtures at walk through inspection VEHICLE DOORS VEHICLE DOORS The garage doors up limit switches did not operate at the time of the inspection. When the doors go to the up positions the hard stops have to stop the door. This action will eventually damage the door. The door up limit switches need to be repaired or replaced. Recommend further evaluation and repairs by an appropriate garage door service expert/contractor. Garage door spring, cable tension and sensors require trained service person to perform adjustments/replacement. Infrared safety devices are not found on older type openers, upgrade kits are available. MASTER BATHROOM Cabinets and Accessories The medicine mirror is chipped/broken. Recommend replacing. Toilet Bowl and Tank The toilet bowl mount is loose. Recommend replacing the toilet bowl wax ring before properly securing the toilet. A competent plumber handyman/person can be used to complete this repair. Shower The shower wall safety bar mounts are loose. Recommend properly securing the bar mounts. Summary: Page 4 of 5 Canyon State Property Inspections

7 Page 7 of 22 INTERIOR Interior Doors Service/Repair The master bathroom toilet door is missing/not installed. Recommend installing the same style door at the bathroom to match the surrounding doors. A competent handyman/person can be used to complete this repair. POOL Electrical Three of the pool light did not operational at the time of the inspection. Recommend further evaluation and repairs by a certified pool technician or electrician. Monitor/Maintain GROUNDS Landscaping Tree(s) are coming into contact with the house causing or may cause damage to the structure/components. Recommended further evaluation and repairs by an appropriate contractor. Trimming of the vegetation around the house is needed. The vegetation is coming into contact with the house. Recommend trimming the vegetation at least twelve inches back away from the house. A competent lawn service can be used to complete this repair. AIR MANAGEMENT Return Air Filter Type and Location The return air inlet filter is dirty. The dirt on the filter reduces the airflow over the fins on the evaporator coil. Dirt on the coils will result in decreased operating efficiency and shortened service life. Recommend cleaning the filter. POOL Pool is There are several large cracks between the pool deck and pool body allowing for water entry. Recommend removing all loose surface material from the cracks before sealing/caulking the cracks. A competent handyman/person can be used to complete this repair. Deck Material Appears to be The pool deck has a minor settling crack at the southeast side that should be sealed with a caulking that seals to concrete to help prevent further cracking and settling. A competent handyman/person can be used to correct this defect. Equipment The pool heat combustion section was full of debris and needs to be cleaned. Summary: Page 5 of 5 Canyon State Property Inspections

8 Page 8 of 22 Major Defect Inspection Report Details ROOF MAIN ROOF - Recommend further Recommend evaluation further by a roofer evaluation by a roofer The roll roofing is at or past its end of life. Evidence of patch work. Debris on the roof should be removed. The debris restricts the flow of water off the roof and creates areas for potential standing water. How Inspected - Walk on Roof Walk on Roof Roof Style - Flat/Low Slope Flat/Low Slope Low clearance and the absence of walkways may prevent inspection of all attic areas. Major Defect Roof Covering - Rolled Mineral Rolled Mineral There are areas of cut/torn/weathered and damaged roll roofing. The roll roofing should be replaced to prevent water damage/dry rot to the roof sheathing and structure. Recommend further evaluation and repairs by a competent licensed roofing contractor. 15 thru 20 Approx. Age - 15 thru 20 1 Number of Layers - 1 Roof Vents Roof Ventilation System - Roof Vents Flashing - Aluminum, Mastic Aluminum, Mastic Plumbing Vents - ABS ABS Skylight - Domed Domed EXTERIOR EXTERIOR - Outside Outlets - Tested Tested Wood or Metal Framing, 1 Story Type of Home - Wood or Metal Framing, 1 Story Service/Repair Soffit\Fascia\Trim\Eaves - Wood, Wood, Stucco Stucco The garage door wood trim boards have areas of weathering that need to be painted. Siding/Exterior walls - Stucco, Stucco, Parapet Parapet wall wall Hairline cracks in stucco walls are considered normal due to shrinkage during the curing and drying process. Inspection Details: Page 1 of 15 Canyon State Property Inspections

9 Page 9 of 22 EXTERIOR Support Columns - Wood Wood Entry Doors - Wood Wood Service/Repair Patio Doors - Sliding Sliding The sliding glass door wheels do not properly slide. The wheels have a very difficult time move. Recommend repairing or replacing the wheels for proper operation/movement. A competent handyman/person can be used to complete this repair. Major Defect Other Exterior Doors - Metal Metal The garage service door is damage along the doorframe. The damage appears to be caused by a wood-destroying insect. Recommend having written confirmation by a licensed pest/termite inspector and treatment to prevent further/continued damage. Recommend repairing/replacing any/all structural issue damage. Refinish the doorframe and wall surfaces to like the surrounding area. A competent handyman/person can be used to complete this repair. Window Material - Aluminum Aluminum There are three windows at the southwest side of the house which have been drywalled over. These windows are in the foyer and hallway at the upper level. Window Type - Sliding, Fixed Sliding, Fixed Dual Pane, Glass Block Glass - Dual Pane, Glass Block Determining the failure of thermal pane seals is limited to observing fogging and moisture between the glass panes. Service/Repair Window Screens - MFG Screens MFG Screens Weathered screens Missing screen(s) Weather Stripping - Rubber\Vinyl Rubber\Vinyl Caulking - Windows Windows GROUNDS GROUNDS - Driveway - Concrete Concrete Hairline cracks in concrete and masonry are considered normal due to concrete shrinkage. Walks - Concrete Concrete Hairline cracks in concrete and masonry are considered normal due to concrete shrinkage. Steps/Stairways - Concrete Concrete Hairline cracks in concrete and masonry are considered normal due to concrete shrinkage. Hand Rail - Metal Metal Patio - Concrete Concrete Hairline cracks in concrete and masonry are considered normal due to concrete shrinkage. Porches/Entry - Concrete Concrete Hairline cracks in concrete and masonry are considered normal due to concrete shrinkage. Inspection Details: Page 2 of 15 Canyon State Property Inspections

10 Page 10 of 22 Monitor/Maintain GROUNDS Gentle Slope Visual Grade/Drainage - Gentle Slope Landscaping - Typical trimming Typical of trees trimming needed, of Typical trees needed, trimming Typical of vegetation needed, Vegetation hides walls trimming preventing of vegetation full inspection needed, Vegetation hides walls preventing full inspection Tree(s) are coming into contact with the house causing or may cause damage to the structure/components. Recommended further evaluation and repairs by an appropriate contractor. Trimming of the vegetation around the house is needed. The vegetation is coming into contact with the house. Recommend trimming the vegetation at least twelve inches back away from the house. A competent lawn service can be used to complete this repair. Service/Repair Retaining Wall - Concrete Concrete The east retaining wall has areas of effloresces, chipping and peeling paint which appears to be cause by the plant/flower boxes behind the wall. If the boxes are going to be continued to be used for plants, which will require regular watering it is recommended that the boxes, which hold the plants, be sealed with a water sealant to protect the wall from deterioration. Fences - Masonry, Metal Masonry, Metal Gates - Wood, Metal Wood, Metal GUTTERS GUTTER SYSTEM - Roof, Ground Inspected From - Roof, Ground Scuppers, Aluminum Gutter Type - Scuppers, Aluminum COOLING COOLING SYSTEM - Coolant charge, line integrity, system capacity, efficiency or air volume is beyond the scope of this inspection. Recommend yearly maintenance/servicing done by a trained and competent HVAC service person. If there is no records of complete servicing of the unit in the last 12 months it is recommended that the unit be serviced by a trained and competent HVAC service person before the close of escrow. Cooling System Location - Roof Roof Trane Cooling System Brand - Trane Split System Cooling System Type - Split System 5 Ton Cooling System Tonnage - 5 Ton 15 plus Cooling System Approx. Age - 15 plus Unit very old and extended life should not be expected. Recommend financially preparing for replacement. Inspection Details: Page 3 of 15 Canyon State Property Inspections

11 Page 11 of 22 COOLING Clean Cooling System Coils and Fins - Clean Ext. Disconnect, 220 volt Cooling System Electrical - Ext. Disconnect, 220 volt Insulation Cooling System Lines - Insulation Plastic Cooling System Condensate Drain - Plastic Details Cooling System Differential Temp - Details The difference between the supply and return air is 17 degrees Safety Concern FUEL SYSTEM FUEL SYSTEM - General Comments, General Overall Comments, condition Overall is good condition and appears is good functional and appears functional There is a gas odor and leak detected at the pool heater at the time of the inspection. The gas company needs to be notified immediately for further evaluations and repairs. It is advised that the local Gas Company light all pilots for ALL gas appliances prior to the close of this transaction. The reason for this recommendation is that the Gas Company routinely performs safety tests on gas fixtures. These tests can reveal problems, which may not be discovered in the course of a limited visual property inspection. Tests for gas leaks or pipe sizing are not performed. The presence or condition of underground fuel storage tanks is not part of this inspection. Type of Gas - Natural Gas Natural Gas East, Yard Gas Meter Location - East, Yard At Meter Main Shut Off Valve Location - At Meter At Appliances Other Shut Off Valve(s) Locations - At Appliances ELECTRIC ELECTRICAL SYSTEM - North, side/corner of exterior wall Main Electrical Panel Location - North, side/corner of exterior wall Underground Main Electrical Service - Underground Undetermined Main Electrical Service Wire - Undetermined 200 Main Panel Service Size Inspection Details: Page 4 of 15 Canyon State Property Inspections

12 Page 12 of 22 ELECTRIC Breaker Main Electrical Disconnect - Breaker Breakers Main Electrical Panel Circuits - Breakers Grounding - Ufer Ufer 110 / 220 Voltage Available / 220 Copper Interior and Exterior House Wiring - Copper Wiring in attic/sub-area mostly hidden from view Type of House Wire - Non-Metallic Non-Metallic Sheathed Sheathed Swimming Pool/Spa Equipment Sub Electrical Panel Location - Swimming Pool/Spa Equipment Copper Sub Panel Feeder Electrical Service Wire - Copper 15 Sub Panel Service Size - 15 LIGHTS & OUTLETS General Comments LIGHTS and OUTLETS - General Comments Function of some switches was not determined. Safety Concern Electrical Receptacles - 3 Slotted, 3 Slotted, GFCI GFCI The southwest porch outlet receptacle is broken/damaged. This is an electrical shock hazard. Recommend having a handyman replace the outlet receptacle. GFCI Outlet location(s) - Bathroom(s), Bathroom(s), Kitchen, Kitchen, Garage, Garage, Exterior Exterior Service/Repair Switches and Light Fixtures - Burned Burned out out and and or or missing missing bulbs bulbs observed observed Recommend replacing bulbs to verify function of light fixtures at walk through inspection PLUMBING PLUMBING - Most supply, vent and drain pipes/lines are not visible during an inspection due to wall, floor, ceiling finishing and attic insulation. Under sink and other service shut off valves are not tested, due to non-use these valves typically are prone to leakage and breakage when operated. City sewer service, septic systems and all underground pipes are out of the scope of this inspection. Water filters, water-conditioning systems and fire sprinklers are not included unless stated otherwise. The locations and number of drainage clean outs is not determined. Drainage performance of solids cannot be predicted with certainty. Water Source - Municipal Municipal Meter Location - Unknown Unknown Inspection Details: Page 5 of 15 Canyon State Property Inspections

13 Page 13 of 22 PLUMBING Unknown Main Valve Location - Unknown Main Supply Line - Copper Copper None found Other Shut Off Valves - None found Observed at all fixture Functional Flow and Drainage - Observed at all fixture Hose bibs are functional Hose Bibs - Hose bibs are functional The hose bibs are functional, but we may not have located and tested every one on the property. Pressure Test PSI PSI PSI Pressure Test at - South Hose South Bib Hose Bib Copper Interior Visible Water Pipes - Copper Waste System - Municipal Municipal ABS Interior Waste/Vent Pipes - ABS PARKING STRUCTURE PARKING STRUCTURE - Full inspection prevented by storage of personal items. Size - 2 Car Attached 2 Car Attached Drywall\Plaster Interior Walls - Drywall\Plaster Full inspection prevented by personal property. Safety Concern Interior Ceiling - Drywall\Plaster Drywall\Plaster There are 2 vent holes in the garage ceiling compromising its fire integrity. The vents needs to be removed and the ceiling needs to be properly patched with ½ inch gypsum board (fire rated 5/8 inch drywall) or 16 gage ducting needs to be properly installed for fire integrity. Recommend further evaluation and repairs by a competent contractor. There is water stains in the ceiling. This is an indication of a roof leak in that general area. Recommend further evaluation and repairs by a competent licensed contractor. Garage Floor - Concrete Concrete Full inspection prevented by storage of personal items or vehicles Door to Interior - Solid Core Solid Core Floor, 40%, Walls, 40% Observable Area - Floor, 40%, Walls, 40% Inspection Details: Page 6 of 15 Canyon State Property Inspections

14 Page 14 of 22 PARKING STRUCTURE Attic Access - None None Door to the Exterior - Metal Metal Service/Repair VEHICLE DOORS VEHICLE DOORS - General Comments General Comments The garage doors up limit switches did not operate at the time of the inspection. When the doors go to the up positions the hard stops have to stop the door. This action will eventually damage the door. The door up limit switches need to be repaired or replaced. Recommend further evaluation and repairs by an appropriate garage door service expert/contractor. Garage door spring, cable tension and sensors require trained service person to perform adjustments/replacement. Infrared safety devices are not found on older type openers, upgrade kits are available. Number of Doors - 2 Single Car 2 Doors Single Car Doors 1, Infrared safety sensors and auto reverse tested Number of Automatic Openers - 1, Infrared safety sensors and auto reverse tested Garage Door Type - Roll Up Roll Up Door Material - Metal, Glass Metal, Glass Insulated - Yes Yes Major Defect W. HEATER WATER HEATER - General Comment General Comment The water heater is making a popping sound caused by loose sediment in the tank. This sediment will reduce the heating capacity of the unit over time. The water heater has excessive rust flakes in the burner compartment. This is and indication that the unit is at its end of life. Recommend replacing the unit. Recommend further evaluation and repairs by a competent water heater service technician/plumber contractor. TPR- (Temperature Pressure Release valves) are recommended to be tested yearly by the property owner. Inspector performing test of valves is outside the scope of this inspection. Function of hot water circulating pumps is not verified. Location of Water Heater(s) - Garage Garage Water Heater Mfg. - American American 15 plus Water Heater Approx. Age - 15 plus Unit old and extended life should not be expected. 50 Water Heater Size - 50 Inspection Details: Page 7 of 15 Canyon State Property Inspections

15 Page 15 of 22 W. HEATER Water Heater Fuel - Gas Gas Double Wall Water Heater Flue Pipe - Double Wall On Off Valve at unit Water Heater Gas Piping - On Off Valve at unit Present Water Heater Cold Water Valve - Present Present Temp. Pressure Relief Valve and Pipe - Present OK Water Heater Exterior Jacket - OK LAUNDRY LAUNDRY - No Machines Installed Access - No Machines Installed Water flow not tested Washer supply valve - Hot and Hot Cold and Gate Cold Valve Gate Valve Rubber hoses Washer Supply Line hoses - Rubber hoses Rubber washing machines water supply line hoses are temporary hose that are not meant for long-term usage. Recommend replacing the rubber hoses with metal braided hoses as a preventative measure. Washer Drains - Trapped Line Trapped Line Dryer Vented - Wall Wall 220 Electric and Gas Laundry Energy Source Electric and Gas Vent Fan - Working Working Wood and Compress board Laundry Room Cabinets - Wood and Compress board Interior of all cabinets not inspected. View below sink and in cabinets restricted by supplies, etc. KITCHEN KITCHEN - Wood and Compress board Kitchen Cabinets - Wood and Compress board Interior of all cabinets not inspected. Inspection Details: Page 8 of 15 Canyon State Property Inspections

16 Page 16 of 22 KITCHEN Kitchen Counter - Tile Cracks in counter top Kitchen Sink - Metal Enamel Tile Metal Enamel Single Lever Kitchen Sink Faucet - Single Lever Sprayer Kitchen Sink Other Faucet(s) - Sprayer Kitchen Drain and Trap - ABS ABS Batch Feed Garbage Disposal - Batch Feed High Loop Method Dishwasher Drainage Line - High Loop Method Over 15 years, Older unit, may have limited life Dishwasher Approximate Age - Over 15 years, Older unit, may have limited life Older unit may have limited life Over Stove Built-in Microwave - Over Stove Trash Compactor - None None Older unit may have limited life Older unit may have limited life Older unit may have limited life Integral with Microwave Exhaust Fan - Integral with Microwave Range Oven - Electric Surface Cook top - Electrical Electric Electrical HALLWAY BATHROOM HALLWAY BATHROOM - Bathroom Receptacles - GFCI GFCI Elec. Fan Outdoors, Window Bathroom Exhaust System - Elec. Fan Outdoors, Window Central Sys Bathroom Heating Cooling - Central Sys Bathroom Floor - Tile Tile Inspection Details: Page 9 of 15 Canyon State Property Inspections

17 Page 17 of 22 HALLWAY BATHROOM Gated Type Bathroom Sink Faucets - Gated Type Push Pull Bathroom Sink Stopper - Push Pull ABS Bathroom Sink Drain and Trap - ABS Vanities - Molded Vanity Top Molded Vanity Top Wood and Compress Board Cabinets and Accessories - Wood and Compress Board 2 Piece Toilet Bowl and Tank - 2 Piece Bath Showerhead - Personal Personal Bathtub - Acrylic Acrylic Shower - Acrylic Acrylic Floor Drain Stall Shower Drain - Floor Drain Stall Single Lever Shower Faucets - Single Lever Observed at all fixture Functional Flow and Drainage - Observed at all fixture MASTER BATHROOM MASTER BATHROOM - Bathroom Receptacles - GFCI GFCI Elec. Fan Outdoors Bathroom Exhaust System - Elec. Fan Outdoors Central Sys Bathroom Heating Cooling - Central Sys Bathroom Floor - Carpet Carpet Gated Type Bathroom Sink Faucets - Gated Type Inspection Details: Page 10 of 15 Canyon State Property Inspections

18 Page 18 of 22 MASTER BATHROOM Push Pull Bathroom Sink Stopper - Push Pull ABS Bathroom Sink Drain and Trap - ABS Vanities - Molded Vanity Top Molded Vanity Top Service/Repair Cabinets and Accessories - Wood Wood and and Compress Compress Board Board The medicine mirror is chipped/broken. Recommend replacing. Service/Repair Toilet Bowl and Tank - 2 Piece 2 Piece The toilet bowl mount is loose. Recommend replacing the toilet bowl wax ring before properly securing the toilet. A competent plumber handyman/person can be used to complete this repair. Bathtub Faucets - Gated Type Gated Type Bathtub Stopper - Pop Up Pop Up Bath Showerhead - Standard Standard Bathtub - Acrylic Whirlpool tub functioned at the time of the inspection. Service/Repair Shower - Acrylic Acrylic Acrylic The shower wall safety bar mounts are loose. Recommend properly securing the bar mounts. Shower Drain - Floor Drain Stall Floor Drain Stall Single Lever Shower Faucets - Single Lever Observed at all fixture Functional Flow and Drainage - Observed at all fixture WEST BATHROOM WEST BATHROOM - Bathroom Receptacles - GFCI GFCI Elec. Fan Outdoors Bathroom Exhaust System - Elec. Fan Outdoors Central Sys Bathroom Heating Cooling - Central Sys Bathroom Floor - Carpet Carpet Inspection Details: Page 11 of 15 Canyon State Property Inspections

19 Page 19 of 22 WEST BATHROOM Gated Type Bathroom Sink Faucets - Gated Type Push Pull Bathroom Sink Stopper - Push Pull ABS Bathroom Sink Drain and Trap - ABS Vanities - Molded Vanity Top Molded Vanity Top Wood and Compress Board Cabinets and Accessories - Wood and Compress Board 2 Piece Toilet Bowl and Tank - 2 Piece Single Lever Bathtub Faucets - Single Lever Bathtub Stopper - Pop Up Pop Up Bath Showerhead - Personal Personal Bathtub - Metal Enamel Metal Enamel Shower - Acrylic Acrylic Shower Drain - Tub Tub Shower Faucets - Tub Tub Observed at all fixture Functional Flow and Drainage - Observed at all fixture INTERIOR INTERIOR ROOMS - Interior Rooms - Living Room, Living Dining Room, Room, Dining Den/Office, Room, Laundry Den/Office, Room Laundry Room 2 Number of Bedrooms - 2 Interior Walls - Dry Wall Dry Wall Inspection Details: Page 12 of 15 Canyon State Property Inspections

20 Page 20 of 22 INTERIOR Dry Wall, Wood Interior Ceilings - Dry Wall, Wood Interior Floors - Tile, Carpet Tile, Carpet Service/Repair Interior Doors - Simulated Panel, Simulated Hinged Panel, Hinged The master bathroom toilet door is missing/not installed. Recommend installing the same style door at the bathroom to match the surrounding doors. A competent handyman/person can be used to complete this repair. Closet Doors - Simulated Panel, Simulated Mirror/Glass, Panel, Sliding, Mirror/Glass, Hinged Sliding, Hinged Windows - Operated Operated Ceiling Fan - Tested Tested All detectors responded to test, Hallway(s) Smoke Detectors - All detectors responded to test, Hallway(s) Smoke detectors/alarms have a life expectancy of approximately 10 years. If you don't know how old the smoke detectors/alarms are, replace them. Installing additional detectors recommended in the bedroom but not required Major Defect FIREPLACES AND WOOD STOVES FIREPLACES AND WOOD STOVES General - General Comment Comment The master bedroom and living room gas fireplace did not function at the time of the inspection. The igniter did not spark to light the gas pilot. Recommend further evaluation and repairs by a certified gas fireplace technician. Location - Living Room, Bedroom(s) Living Room, Bedroom(s) 2 Number of Fireplaces/Wood stoves - 2 Type - Prefabricated Prefabricated Roof Chimney Inspected From - Roof Stucco, Metal Chimney Exterior - Stucco, Metal Chimney Flue - Metal Metal Fuel Type - Natural Gas Natural Gas Rain Cap, Screen Chimney Cap - Rain Cap, Screen Inspection Details: Page 13 of 15 Canyon State Property Inspections

PROPERTY INSPECTION REPORT

PROPERTY INSPECTION REPORT (850) 297-1998 1716 Monticello Dr Tallahassee, Florida 32303 PROPERTY INSPECTION REPORT THIS INSPECTION IS A DETAILED LISTING OF AREAS VISUALLY INSPECTED AT:, Tallahassee FL Client Tallahassee, FL 32304

More information

COMPREHENSIVE PROPERTY INSPECTIONS

COMPREHENSIVE PROPERTY INSPECTIONS COMPREHENSIVE PROPERTY INSPECTIONS Thank you for selecting CPI for your Deficiency Observation. A full home inspection was not performed on this property at the buyers request. This inspection is a limited

More information

Georgia Home Inspection Services

Georgia Home Inspection Services Cover Page Property Inspection Report My street, Anytown GA, 30000 Inspection prepared for: John Doe Inspection Date: 7/18/2011 Time: 5pm Age: 25+ Size: >1500 Weather: Clear This ranch style home is in

More information

Quality Home Inspections, LLC 4433 Tennyson Street Denver, Colorado 80212 303-885-1288

Quality Home Inspections, LLC 4433 Tennyson Street Denver, Colorado 80212 303-885-1288 Page 1 of 22 Quality Home Inspections, LLC 4433 Tennyson Street Denver, Colorado 80212 303-885-1288 Printed Friday, January 16, 2015 Inspected By: Dale Gibbs Referral Information Joe Agent Client Information:

More information

Home Inspection Report

Home Inspection Report 4949 Brownsboro Rd Suite 293 Louisville, KY 40223 (502) 414-1440 tripleainspections@gmail.com Inspected By: William Carter, HI-1956 Home Inspection Report Prepared For: Edward Cullen Property Address:

More information

Vari Inspection Services

Vari Inspection Services Cover Page Vari Inspection Services Property Inspection Report Inspection prepared for: Sample Real Estate Agent: None - Date of Inspection: 5/13/2015 Inspector: Tony Vari License # HI8047 23110 STRD 54

More information

www.citiesinspection.com October 5, 2015 Dear Client,

www.citiesinspection.com October 5, 2015 Dear Client, www.citiesinspection.com October 5, 2015 Dear Client, On 9/14/2015, Cities Inspection Service, Inc. completed a building inspection of the property located at 123 Oak Street, Someplace, Minnesota for you.

More information

SWF Home Inspections

SWF Home Inspections Cover Page SWF Home Inspections Property Inspection Report Inspection prepared for: Mr & Mrs Home Buyer Real Estate Agent: My Favorite Agent - Date of Inspection: 7/4/2013 Age of Home: 2004 Size: 1568

More information

Printed Monday, August 27, 2007 Inspected By: Michelle Teague. Client Information: Inspection, Condo City Lane Chicago, IL. Inspected 8/22/07 8:00 AM

Printed Monday, August 27, 2007 Inspected By: Michelle Teague. Client Information: Inspection, Condo City Lane Chicago, IL. Inspected 8/22/07 8:00 AM Pa g e 1 o f 1 5 All About Homes, LLC Michelle M. Teague Owner 312-371-7414 Phone 773-508-6209 Fax www.michelleinspects.com michelle@michelleinspects.com 1725 W. Granville Ave. Chicago, IL 60660 Printed

More information

Report for. Dick and Jane Homeowner. 1234 Lovers Lane, Houston, Texas 77000

Report for. Dick and Jane Homeowner. 1234 Lovers Lane, Houston, Texas 77000 Report for Dick and Jane Homeowner 1234 Lovers Lane, Houston, Texas 77000 March 17, 2004 I NI NP R Inspection Item I. STRUCTURAL SYSTEMS o o o A. Foundations (If all crawl space areas are not inspected,

More information

A.C.E. Home Inspection Service www.acehomeweb.com St. Peters, MO 63376 (636) 978-9111

A.C.E. Home Inspection Service www.acehomeweb.com St. Peters, MO 63376 (636) 978-9111 A.C.E. Home Inspection Service www.acehomeweb.com St. Peters, MO 63376 (636) 978-9111 Inspector Name: Tim Knight, ASHI Member 202490 Inspection No: 12121212 Inspection Date: 1/1/2012 Client: Address: John

More information

Self-Home Inspection Checklist

Self-Home Inspection Checklist To be used as a first home visit for note taking. Visit www.homeinspectiondirect.com for more tips and information about buying a home and hiring a home inspector. This form in no way replaces a professional

More information

Inspection Tech. (330) 310-6559 http://www.inspectiontech.us a_westerburg@inspectiontech.us Inspected By: Aaron Westerburg

Inspection Tech. (330) 310-6559 http://www.inspectiontech.us a_westerburg@inspectiontech.us Inspected By: Aaron Westerburg Inspection Tech (330) 310-6559 http://www.inspectiontech.us a_westerburg@inspectiontech.us Inspected By: Aaron Westerburg Inspection Tech Home Inspection Report Prepared For: Mr. & Mrs. Homebuyer Property

More information

Home Inspection Report

Home Inspection Report Report# 21009 Page 1 of 24 Home Inspection Report Property Address: 123 Maple Lane, St. Augustine, FL 32092 Prepared For: Mr. Smith Prepared By: EDGE Inspections www.edgeinspections.com PO Box 601055 Jacksonville,

More information

PROPERTY INSPECTION REPORT Property Address:

PROPERTY INSPECTION REPORT Property Address: Scott Certified Member P. O. Box 9007 Indianapolis, IN 690-007 (7)-750-60 Fax: 7-876-8 PROPERTY INSPECTION REPORT Property Address: Prepared for: Inspection Inspector: Lou Buehler Inspection #: BUYERS

More information

HOME INSPECTION CHECKLIST

HOME INSPECTION CHECKLIST CLOSING.COM LEARNING CENTER HOME INSPECTION CHECKLIST CONTENTS Attic 1 Balconies 1 Basement 1 Bathroom 2 Ceiling, Floors and Walls 2 Crawlspace 3 Decks and Porches 3 Doors and Windows 4 Drainage 4 Driveways

More information

Report Index PROPERTY DESCRIPTION 1 ELECTRICAL SYSTEM 2 COMMON INTERIOR AREAS 3 INTERIOR ROOMS 6 KITCHEN 8 BATHROOMS 10

Report Index PROPERTY DESCRIPTION 1 ELECTRICAL SYSTEM 2 COMMON INTERIOR AREAS 3 INTERIOR ROOMS 6 KITCHEN 8 BATHROOMS 10 Report Index PROPERTY DESCRIPTION 1 ELECTRICAL SYSTEM 2 COMMON INTERIOR AREAS 3 INTERIOR ROOMS 6 KITCHEN 8 BATHROOMS 10 PROPERTY DESCRIPTION PROPERTY INSPECTED: INSPECTION ADDRESS: 4722 Baltimore Avenue

More information

Propery Inspection Report

Propery Inspection Report Propery Inspection Report Cover Page,, Ok Inspection prepared for: Date of Inspection: 9/28/2014 Time: 8:30 AM Age of Home: 2011 MOL Weather: Clear 62 degrees Inspector: License #130 5400 Hwy 177, Marland,

More information

Vision Home Inspection

Vision Home Inspection Vision Home Inspection 324 Rams Run Shepherdsville KY 40165-7877 Inspector: James McFadden Property Inspection Report Client(s): Property address: Inspection date: View report summary This report is the

More information

Orlando Home Inspection Services

Orlando Home Inspection Services PLEASE NOTE: Orlando Home Inspection Services Serving Central Florida since 1999 P O Box 915451, Longwood, Florida, 32791-5451 Phone: (321) 228-2493 Fax: (407) 374-8505 Web: http://www.orlando-home-inspections.com

More information

Total Home Inspection Checklist

Total Home Inspection Checklist Total Home Inspection Checklist Use a checklist like this to make sure that you are looking at all parts of the house. Check off those items that are in good condition and make notes about those that are

More information

I NI NP R Inspected Items

I NI NP R Inspected Items 6/ /07 The Inspection of the property listed above must be performed in compliance with the rules of TREC. The inspection is of conditions which are present and visible at the time of the inspection, and

More information

INVOICE. DATE: May 11, 2005. DESCRIPTION Inspection and report on a property located at OF SERVICES: Perfect Street, Sarasota, Fl.

INVOICE. DATE: May 11, 2005. DESCRIPTION Inspection and report on a property located at OF SERVICES: Perfect Street, Sarasota, Fl. INVOICE DATE: May 11, 2005 CLIENT: The Buyer DESCRIPTION Inspection and report on a property located at OF SERVICES: Perfect Street, Sarasota, Fl. TOTAL FEE: $ See Schedule Tom Villani Hallmark Inspection

More information

Accurate Home Inspection of Illinois. Property Inspection Report For Steve & Jenny Hynek 210 W.Chicago Ave., Westmont, Illinois

Accurate Home Inspection of Illinois. Property Inspection Report For Steve & Jenny Hynek 210 W.Chicago Ave., Westmont, Illinois Accurate Home Inspection of Illinois 815-260-1727 1213 Norley st. Joliet, illinois 60435 aaccurate1@yahoo.com We Inspect to Protect!!! Property Inspection Report For Steve & Jenny Hynek 210 W.Chicago Ave.,

More information

Inspection Item COMMENTS

Inspection Item COMMENTS APPENDIX 9 AFFORDABLE HOUSING PROGRAM INSPECTION CHECKLIST Participating Jurisdiction: Homeowner Name: Assisted Property Address: Date of Physical Inspection of Property: Total Square Footage of Property:

More information

Inspection Report Atlanta Strip Mall Commercial Building Property Address:

Inspection Report Atlanta Strip Mall Commercial Building Property Address: Page 1 of 25 Inspection Report Atlanta Strip Mall Property Address: Smyrna GA 30082 Page 2 of 25 South East Building Consultants Ray Thoroman Serving the entire State of Georgia 6 678-410-3005 Page 3 of

More information

Inspecton Report. Property Address:

Inspecton Report. Property Address: Inspecton Report Provided by: National Home Inspections Inspector: Bob Smith 456 S Main Denver, CO 46312 (645) 423-3242 bob@nationalhomeinspections.com www.nationalhomeservices.com Property Address: 873

More information

Home Systems Data Inc. 7305 E. Peakview Ave. Centennial CO. 80111 303-773-6102

Home Systems Data Inc. 7305 E. Peakview Ave. Centennial CO. 80111 303-773-6102 Page 1 of 26 Home Systems Data Inc. 7305 E. Peakview Ave. Centennial CO. 80111 303-773-6102 Printed Friday, January 14, 2011 Inspected By: None None Realtor NONE Client Information: Name, Your 123 Street

More information

BOROUGH OF NATIONAL PARK APPLICATION FOR A CERTIFICATE OF OCCUPANCY FOR CHANGE OF OCCUPANCY ADDRESS OF PROPERTY FOR INSPECTION CURRENT OWNER

BOROUGH OF NATIONAL PARK APPLICATION FOR A CERTIFICATE OF OCCUPANCY FOR CHANGE OF OCCUPANCY ADDRESS OF PROPERTY FOR INSPECTION CURRENT OWNER BOROUGH OF NATIONAL PARK APPLICATION FOR A CERTIFICATE OF OCCUPANCY FOR CHANGE OF OCCUPANCY ADDRESS OF PROPERTY FOR INSPECTION # BLOCK LOT VACANT YES NO CURRENT OWNER NAME ADDRESS TELEPHONE # PROSPECTIVE

More information

Crawford Inspection Services C.C.B. # 76914 www.crawfordinspections.com

Crawford Inspection Services C.C.B. # 76914 www.crawfordinspections.com Crawford Inspection Services C.C.B. # 76914 www.crawfordinspections.com Portland Area PO Box 665 West Linn, OR 97068 Ph: (503) 650-6957 Salem Area 5434 River Rd. N; #192 Keizer, OR 97303 Ph: (503) 362-5809

More information

Inspection Report. Dream Home Inspections. www.timinspects.com. 415 Second Ave. Frisco CO 80443-1789 (970) 368-2668

Inspection Report. Dream Home Inspections. www.timinspects.com. 415 Second Ave. Frisco CO 80443-1789 (970) 368-2668 Inspection Report Property Address: 123 Dream Home Way Frisco, CO 80443 Prepared for: Inspector: Tim Nixon Tim Nixon Inspection date: 3/28/2014 1 of 9 General Information Property Information Address:

More information

A and S Property Inspector

A and S Property Inspector Cover Page A and S Property Inspector Property Inspection Report Inspection prepared for: xxxxx xxxxx Real Estate Agent:.. - Date of Inspection: 8/25/2014 Time: 10am Age of Home: 1999 Size: 1841 Weather:

More information

South Carolina Home Inspector Standards of Practice

South Carolina Home Inspector Standards of Practice South Carolina Home Inspector Standards of Practice The following Standards provide guidelines for the Residential Home Inspector and outline what the Residential Home Inspector should observe, identify,

More information

Burns Home Services SUMMARY REPORT. 7/18/2006 Start: 9:00 am End: 12:30 pm

Burns Home Services SUMMARY REPORT. 7/18/2006 Start: 9:00 am End: 12:30 pm Burns Home Services Service Makes the Difference 2620 W Grovers Ave, Phoenix, AZ 85053 Tel: 602-889-6970 Fax: 602-870-4563 Mobile: 602-291-7138 Garryh@burnshomeservices.com SUMMARY REPORT Client: John

More information

PEPPER VINER HOMES WARRANTY GUIDELINES

PEPPER VINER HOMES WARRANTY GUIDELINES PEPPER VINER HOMES WARRANTY GUIDELINES All non-emergency warranty and customer service requests MUST be made in writing. This provides you with documentation and allows Pepper Viner to operate efficiently.

More information

CHRIS CURLES and ASSOCIATES INSPECTION SERVICES

CHRIS CURLES and ASSOCIATES INSPECTION SERVICES CHRIS CURLES and ASSOCIATES INSPECTION SERVICES Inc. Chris Curles, President www.homeinspectionsatlanta.com chriscurl@comcast.net Office: 770-493-0227 Professional Member Of: GAHI # 93006 ASHI # 211725

More information

Aztec Property Inspections 2719 Mission Blvd San Diego, CA 92109 (858) 245-9329. 6352 Some Road San Diego, CA 92114

Aztec Property Inspections 2719 Mission Blvd San Diego, CA 92109 (858) 245-9329. 6352 Some Road San Diego, CA 92114 2719 Mission Blvd San Diego, CA 92109 (858) 245-9329 Client: Could Be You 6352 Some Road San Diego, CA 92114 Page 1 of 14 Defective Summary This summary is not the entire report. The complete report may

More information

HOMEOWNER S PERMIT GUIDE

HOMEOWNER S PERMIT GUIDE HOMEOWNER S PERMIT GUIDE WHEN IS A PERMIT REQUIRED? Department of Development and Permits 306 Cedar Road, City Hall 2 nd Floor P.O. Box 15225 Chesapeake, VA 23328 Phone: (757) 382-6018 Fax: (757) 382-8448

More information

INSPECTION PROPERTY ADDRESS: Fort Bend County, Texas

INSPECTION PROPERTY ADDRESS: Fort Bend County, Texas 5006 Cherry Ridge Road Richmond, Texas 77406 281-342-9944 harris31@sbcglobal.net INSPECTION PROPERTY ADDRESS: INSPECTION PERFORMED FOR: XXXX Drive Fort Bend County, Texas Mr. and Mrs. New Construction

More information

STATE OF FLORIDA HOME INSPECTION STANDARDS OF PRACTICE:

STATE OF FLORIDA HOME INSPECTION STANDARDS OF PRACTICE: STATE OF FLORIDA HOME INSPECTION STANDARDS OF PRACTICE: 61-30.801 Standards of Practice, General. (1) Home inspections performed to these Standards of Practice are intended to provide the client with information

More information

159 Morningside Avenue, Toronto

159 Morningside Avenue, Toronto 159 Morningside Avenue, Toronto Inspection Report February 6, 2013 159 Morningside Avenue, Toronto Inspection Report Overall Condition: This 60±-year-old home was extensively renovated and extended in

More information

BUILDING DEPARTMENT 8748 W. 82 nd Place - Justice, IL 60458 Phone: (708) 458-2130 Fax: (708) 458-3207

BUILDING DEPARTMENT 8748 W. 82 nd Place - Justice, IL 60458 Phone: (708) 458-2130 Fax: (708) 458-3207 BUILDING DEPARTMENT 8748 W. 82 nd Place - Justice, IL 60458 Phone: (708) 458-2130 Fax: (708) 458-3207 SELF EVALUATION CHECKLIST FOR RESIDENTIAL AND MULTI-FAMILY DWELLING INSPECTIONS The attached checklist

More information

Simplify. Homeownership

Simplify. Homeownership Simplify Homeownership Home Pulse An Innovative Program To Maintain Your Home. The Home Pulse Preventive Maintenance Plan will keep your home looking great, dramatically slow the deterioration process

More information

Summit Series Single Section and Double Section Homes

Summit Series Single Section and Double Section Homes Single Section and Double Section Homes SM-01 All New 20 Wides Now Available! SM-08 Units shown with optional features SM-01-4814 42 Bedrooms 41 Bathrooms 648 Sq. Ft. SM-01-5214 42 Bedrooms 41 Bathrooms

More information

License Requirements for Persons Engaging in the Business of Inspection Practice:

License Requirements for Persons Engaging in the Business of Inspection Practice: SC Standards of Practice SOUTH CAROLINA RESIDENTIAL BUILDERS COMMISSION HOME INSPECTOR STANDARDS OF PRACTICE Adopted by the Residential Builders Commission May 13, 1998 PURPOSE: The purpose of a residential

More information

Inspection Report 95 Old Stage Road East Brunswick NJ Scott Frederick

Inspection Report 95 Old Stage Road East Brunswick NJ Scott Frederick Inspection Report 95 Old Stage Road East Brunswick NJ Scott Frederick Prepared by: The Inspection Guys www.inspectionguys.com 16 Mt. Bethel Road, Suite 171 Warren, NJ 07059 800-903-0670 Fax: 732-238-7092

More information

Schedule of Maintenance Fees

Schedule of Maintenance Fees Schedule of Maintenance Fees Effective July 1, 2015 It is the policy of the Housing Authority of Murray not to charge for NORMAL wear and tear. However, the Housing Authority reserves the right in every

More information

COST OF WORK FORM. Abbreviations: ea = each, LF = linear feet, SF = square feet, HSF = square feet of living area (including garage conversion space)

COST OF WORK FORM. Abbreviations: ea = each, LF = linear feet, SF = square feet, HSF = square feet of living area (including garage conversion space) COST OF WORK FORM All costs shown are estimates using base grade materials, taxes, and labor. For houses where a higher quality is indicated, the costs should be increased for work requiring upgraded materials.

More information

2. What building projects are exempted? (permit not required)

2. What building projects are exempted? (permit not required) BUILDING AND SAFETY DEPARTMENT 1. What building projects require a permit? Following is a list of projects that require building permits based on Appendix chapter 1 of the California Building Code and

More information

Real Estate Inspection Report

Real Estate Inspection Report 1010 22nd Ave N Naples, Florida 34103 Real Estate Inspection Report 470 Golden Gate Blvd W Naples, Florida 34120 Page 1 of 19 Table of Contents Definitions 2 General Information 2 Lots and Grounds 3 Exterior

More information

Inspection Report. Mr. Sample Sample. Property Address: 1234 USA Drive Indianapolis IN 12345. 1234 USA Drive. Morris Home Inspection Group, LLC

Inspection Report. Mr. Sample Sample. Property Address: 1234 USA Drive Indianapolis IN 12345. 1234 USA Drive. Morris Home Inspection Group, LLC Inspection Report Mr. Sample Sample Property Address: 1234 USA Drive Indianapolis IN 12345 1234 USA Drive Morris Home Inspection Group, LLC Cedric Morris HI01200039 Fishers, IN 46037 317-550-6281 Table

More information

Inspecting to a higher standard.

Inspecting to a higher standard. Inspecting to a higher standard. Rob Hopkin Silver Spring, MD 20902 Monday, June 2, 2014 ProTec Inspection Services Inc. 19736 Selby Ave Poolesville, MD 20837 301-972-8531 www.protec-inspections.com rob@protec-inspections.com

More information

South Carolina Home Inspector Standards of Practice

South Carolina Home Inspector Standards of Practice South Carolina Home Inspector Standards of Practice The following Standards provide guidelines for the Residential Home Inspector and outline what the Residential Home Inspector should observe, identify,

More information

Building Condition Assessment Report

Building Condition Assessment Report Building Condition Assessment Report Asset C3c - Oak Terrace Cottage 121 Address Riverview Lands, 2601 Lougheed Highway, Coquitlam, BC. V5C 4J2 Construction Year Size (Gross Floor Area) 1920. 2,553 Sq.Ft.

More information

OC Home Inspect. 333 S Crest Rd Orange, CA 92868 (714) 478-3324 www.ochomeinspect.com guybrianadams@gmail.com Inspected By: Brian Adams

OC Home Inspect. 333 S Crest Rd Orange, CA 92868 (714) 478-3324 www.ochomeinspect.com guybrianadams@gmail.com Inspected By: Brian Adams OC Home Inspect 333 S Crest Rd Orange, CA 92868 (714) 478-3324 www.ochomeinspect.com guybrianadams@gmail.com Inspected By: Brian Adams Comprehensive Property Inspection Prepared For: Property Address:

More information

Home Maintenance Checklist

Home Maintenance Checklist Regular maintenance keeps your home functioning efficiently and safely and helps protect its value. We're happy to offer this checklist of ongoing and seasonal maintenance steps to help you safeguard your

More information

#1) BEFORE Purchasing Land Here Is A Checklist Of Things You Should Check

#1) BEFORE Purchasing Land Here Is A Checklist Of Things You Should Check #1) BEFORE Purchasing Land Here Is A Checklist Of Things You Should Check Zoning laws Deed restrictions on home size, foundation style, roof pitch, etc. Suitability (slope, wetland issues, etc.) Accessibility

More information

CLIENT. Inspection Report. 271 Front St. Alert Bay, B.C. Island Building Inspections V ANCOUVER I SLAND B. C.

CLIENT. Inspection Report. 271 Front St. Alert Bay, B.C. Island Building Inspections V ANCOUVER I SLAND B. C. CLIENT Inspection Report 271 Front St. Alert Bay, B.C. Island Building Inspections 2013 V ANCOUVER I SLAND B. C. Elevation Photos For the Property at 271 Front Street Alert Bay, BC ELEVATION PICTURES Front

More information

INSPECTION REPORT. Client Name Address From the inspection on: August XX, 2011 805-256-5519 CHRIS LOWE

INSPECTION REPORT. Client Name Address From the inspection on: August XX, 2011 805-256-5519 CHRIS LOWE 08XX11aa 805-256-5519 CHRIS LOWE President, Inspector INSPECTION REPORT Client Name Address From the inspection on: August XX, 2011 This report is solely for the use of client personnel. No part of it

More information

Does Wall Township require an inspection by the building department on resale of a home?

Does Wall Township require an inspection by the building department on resale of a home? Selling your home Does Wall Township require an inspection by the building department on resale of a home? No. We do not require a Certificate of Continued Occupancy on the resale of home. A Smoke Detector,

More information

GENERAL WIRING RULES FOR HOUSES

GENERAL WIRING RULES FOR HOUSES GENERAL WIRING RULES FOR HOUSES 1. Romex has to be installed in drilled holes in joists or studs even above suspended ceilings - No stapling to bottom edges of joists or studs. You may staple wire to flat

More information

PROPERTY INSPECTION OR ASSESSMENT OF DAMAGES

PROPERTY INSPECTION OR ASSESSMENT OF DAMAGES PROPERTY INSPECTION OR ASSESSMENT OF DAMAGES ADDRESS: Somewhere, FL CLIENT: GAIA GC ID No: 2015000 DATE: 12/31/2015 INSPECTION OR ASSESSMENT BY: GAIA CONSTRUCTION INC. CGC 1516136 FLORIDA HI-2792 FLORIDA

More information

The UPLANDS at ORO VALLEY Sterling Features

The UPLANDS at ORO VALLEY Sterling Features The UPLANDS at ORO VALLEY Sterling Features STERLING FEATURES Enhanced Air Quality System 2x6 Exterior Walls in Living Area Engineered Post Tension Concrete Slab Dual Pane Low-E Windows Covered Patio Gated

More information

INSPECTION REPORT. LOCATION OF PROPERTY 1234 Sample Street Tucson, AZ 85701. CLIENT Mr. & Mrs. John Q. Sample c/o Agent DATE OF INSPECTION 1/30/2008

INSPECTION REPORT. LOCATION OF PROPERTY 1234 Sample Street Tucson, AZ 85701. CLIENT Mr. & Mrs. John Q. Sample c/o Agent DATE OF INSPECTION 1/30/2008 INSPECTION REPORT LOCATION OF PROPERTY 1234 Sample Street CLIENT Mr. & Mrs. John Q. Sample c/o Agent DATE OF INSPECTION 1/30/2008 INSPECTOR Dave Woityra FILE CODE: 0100114.SAM AGENT Sample Q. Jones A.B.C.

More information

Guaranteed Home Inspections 800 579 5018. HOME INSPECTION REPORT By Kurt Shafer Inspector of Properties

Guaranteed Home Inspections 800 579 5018. HOME INSPECTION REPORT By Kurt Shafer Inspector of Properties Address 9-25-10 Guaranteed Home Inspections 800 579 5018 HOME INSPECTION REPORT By Kurt Shafer Inspector of Properties Buyer Mr. and Mrs. Buyer Address Sample Report Road Temecula CA 92590 Agent Century

More information

HomeSpec REPORT SUMMARY

HomeSpec REPORT SUMMARY HomeSpec 04/25/2007 Ms. Rachel Trujeque Re: 13038 West Plum Road Lot #1225 - Peoria, AZ. 85383 - Pre Drywall Inspection Dear Ms. Trujeque, At your request, a visual pre drywall inspection of the above

More information

Code Enforcement Inspection Manual. City of Virginia Beach Department of Housing and Neighborhood Preservation Code Enforcement Division

Code Enforcement Inspection Manual. City of Virginia Beach Department of Housing and Neighborhood Preservation Code Enforcement Division Code Enforcement Inspection Manual City of Virginia Beach Department of Housing and Neighborhood Preservation Code Enforcement Division LIVING ROOM 304.15 EXTERIOR DOOR(S) Check door(s) and trim for condition,

More information

Building Inspection Report

Building Inspection Report Building Inspection Report 14100 W. Cleveland Avenue, Phoenix, AZ 55555 Inspection Date: 03/18/2002 Prepared For: Mark Newcomer Prepared By: ABC Home Inspections 212 Wisconsin Avenue Scottsdale, AZ 55555

More information

Estimating Database Checklist

Estimating Database Checklist Estimating Database Checklist If you are creating a new estimating database for projects, the following list offers a thorough listing of Main and Sub Categories. You can also use it as a checklist to

More information

PROPERTY INSPECTION OR ASSESSMENT OF DAMAGES

PROPERTY INSPECTION OR ASSESSMENT OF DAMAGES PROPERTY INSPECTION OR ASSESSMENT OF DAMAGES ADDRESS: 123 MAIN ST MIAMI, FL CLIENT: BUYER ID No: 2014193 DATE: 5/13/2014 INSPECTION OR ASSESSMENT BY: GAIA CONSTRUCTION INC. CGC 1516136 FLORIDA HI-2792

More information

U.S. Department of Housing and Urban Development Office of Public and Indian Housing. A Good Place to Live!

U.S. Department of Housing and Urban Development Office of Public and Indian Housing. A Good Place to Live! U.S. Department of Housing and Urban Development Office of Public and Indian Housing A Good Place to Live! Introduction Having a good place to live is important. Through your Public Housing Agency (or

More information

HOME INSPECTION REPORT

HOME INSPECTION REPORT Edgewood Home Inspections, Inc. 407 W. Smith Valley Rd. #1032 Greenwood, IN 46142 (317) 833-6048 HOME INSPECTION REPORT Indianapolis IN 46000 Inspector's Name: License Number: Scott Kissel HI00800073 TABLE

More information

Building Condition Assessment Report

Building Condition Assessment Report C2 - Nurses Resident (aka Administration) Building Condition Assessment Report Asset Address Address Construction Year Size (Gross Floor Area) Asset Type Floors Above Ground Inspection Date C2 - Nurses

More information

Terry Jenkins, Owner Member, American Society of Home Inspectors Virginia Certified Home Inspector Certificate # 3380 000373, expires 1/2010

Terry Jenkins, Owner Member, American Society of Home Inspectors Virginia Certified Home Inspector Certificate # 3380 000373, expires 1/2010 Terry Jenkins, Owner Member, American Society of Home Inspectors Virginia Certified Home Inspector Certificate # 3380 000373, expires 1/2010 Tel: (804) 378-0861 terry@prospectpropertiesva.com Inspection

More information

Inspection Report. Prepared For: Sampath Sample. Property Address: 12712 Waterside Drive. Alpharetta, GA 30004. Atlanta Home Inspections

Inspection Report. Prepared For: Sampath Sample. Property Address: 12712 Waterside Drive. Alpharetta, GA 30004. Atlanta Home Inspections Page 1 of 37 Inspection Report Prepared For: Sampath Sample Property Address: Alpharetta, GA 30004 Atlanta Home Inspections Matthew A Thoroman 6625 Hwy. 53 E. Ste. 410-151 Dawsonville Ga 30534 (678)-410-8062

More information

SAMPLE INSPECTION REPORT PREPARED FOR: John Q Public

SAMPLE INSPECTION REPORT PREPARED FOR: John Q Public 925 W. Baseline Road Suite 105-Y1 Tempe AZ 85283 Tel: 480-456-8809 Fax: 480-456-6139 Mobile: 602-790-0976 www.accuproinspect.com AccuPro@AccuProINSPECT.com SAMPLE INSPECTION REPORT PREPARED FOR: John Q

More information

ROCK-SOLID Inspections

ROCK-SOLID Inspections Home Inspection Services 123 S. Main Street Chicago IL 60000 Inspection prepared for: Joe Citizen Inspection Date: 2-28-2006 Time: 4:30pm Weather: Clear 30 degrees Inspector: Rich Rochowicz 3642 W. 113th

More information

Inspection Report. Prepared for: William Smith 2700 New Street Plano, TX 75025

Inspection Report. Prepared for: William Smith 2700 New Street Plano, TX 75025 Inspection Report Prepared for: William Smith 2700 New Street Plano, TX 75025 This report sample only includes minimal information to display the report's format. Your individual inspection reports may

More information

The Uniform Building Inspection Report Condensed

The Uniform Building Inspection Report Condensed The Uniform Building Inspection Report Condensed Single Family Residence:, Scottsdale, AZ Condensed Report Version Prepared for: John Doe Inspection Date: 9/19/2005, 1:00:00 AM Report Number: 091805s Inspection

More information

Open House and Home Tour Checklist

Open House and Home Tour Checklist 1 The House Address: Number of floors: Listing price: Basement? Property tax: Outdoor space? Eugh closet space? Style: Eugh storage space? Square footage: Room for expansion? Number of bedrooms: What appliances

More information

CONDITION OF QUALITY ITEMS

CONDITION OF QUALITY ITEMS CONDITION OF QUALITY ITEMS FOUNDATION Always look for moisture problems and any bulges or irregularities in the walls. Lines on the walls or floors may indicate water problems. Have these been cured? If

More information

A comfortable house is a great source of happiness. - Sydney Smith. Home Maintenance Guide

A comfortable house is a great source of happiness. - Sydney Smith. Home Maintenance Guide A comfortable house is a great source of happiness. - Sydney Smith Home Maintenance Guide HOME GUIDE By conducting regular maintenance checks, you can prevent small inexpensive repairs from becoming more

More information

Inspection Report. "Even small homes, could have big problems"

Inspection Report. Even small homes, could have big problems Inspection Report "Even small homes, could have big problems" This inspection report prepared specifically for: Happy Buyer Inspect Before You Buy, Order Today. 209.834.5447, CA 88888 Inspected by: Randy

More information

Home Inspection Report

Home Inspection Report Home Inspection Report Cincinnati, Ohio 45000 Prepared for: Dean Murphy Prepared by: BEDROCK ENTERPRISES, INC. 4060 Simca Lane Cincinnati, OH 45211 20:13 July 07, 2008 Page 1 of 18 Definitions NOTE: All

More information

Inspection Report. Jacksonville Krystals Inspection. Property Address: Downtown. Jacksonville FL 32204. South East Building Consultants

Inspection Report. Jacksonville Krystals Inspection. Property Address: Downtown. Jacksonville FL 32204. South East Building Consultants Page 1 of 53 Inspection Report Jacksonville Property Address: Jacksonville FL 32204 South East Building Consultants Ray Thoroman Inspecting Jacksonville FL and entire South East Page 2 of 53 Table of Contents

More information

RRIO Checklist. Use of checklist: Definitions: Limitations

RRIO Checklist. Use of checklist: Definitions: Limitations CITY OF SEATTLE RENTAL REGISTRATION AND INSPECTION ORDINANCE (RRIO) RRIO Checklist Use of checklist: Property owners will use the RRIO Checklist to confirm that their rental housing properties and units

More information

EAST STROUDSBURG BOROUGH RESIDENTIAL RENTAL INSPECTION CHECK LIST

EAST STROUDSBURG BOROUGH RESIDENTIAL RENTAL INSPECTION CHECK LIST DATE TIME EAST STROUDSBURG BOROUGH RESIDENTIAL RENTAL INSPECTION CHECK LIST INSPECTOR: LICENSE # ADDRESS: PROPERTY OWNER: SINGLE: DOUBLE: MULTI-UNIT # OF UNITS POINT OF INSPECTION Sanitation IPMC 302.1

More information

A Residential Owner s Guide to PERMITS. Elgin CITY OF PLANNING & NEIGHBORHOOD SERVICES

A Residential Owner s Guide to PERMITS. Elgin CITY OF PLANNING & NEIGHBORHOOD SERVICES A Residential Owner s Guide to PERMITS CITY OF Elgin PLANNING & NEIGHBORHOOD SERVICES CITY OF Elgin A Residential Owner s Guide Welcome! This booklet has been prepared to provide residential property owners

More information

Inspection Report. Joe Smith. Property Address: 2222 SW 20 St Miramar FL 33028. Coast to Coast Property Inspections

Inspection Report. Joe Smith. Property Address: 2222 SW 20 St Miramar FL 33028. Coast to Coast Property Inspections Inspection Report Joe Property Address: 2222 SW 20 St Miramar FL 33028 Coast to Coast Property Inspections Edmund Villacis HI8060 2114 N Flamingo Rd. #1277 Pembroke Pines, FL 33028 (954) 435-4443 Table

More information

Structure Survey Findings:

Structure Survey Findings: Structure Survey Findings: Visible portions of the following were observed: foundations; structure to walls, columns, floors, roofs, overhang posts, and columns; attached or firmly abutting decks, balconies,

More information

API America s Property Inspections

API America s Property Inspections API America s Property Inspections DESCRIPTION OF HOUSE: Ranch CONCLUSION Mr. xxxx INSPECTION ADDRESS 00/00/2011 APPROXIMATE AGE: 10 years (according to the homeowner) TYPE OF BASIC CONSTRUCTION: Poured

More information

HOME INSPECTOR STANDARDS OF PRACTICE

HOME INSPECTOR STANDARDS OF PRACTICE HOME INSPECTOR STANDARDS OF PRACTICE Adopted by the Residential Builders Commission May 13, 1998, South Carolina Home Inspector Standards of Practice The following Standards provide guidelines for the

More information

Home Inspection Report

Home Inspection Report Home Inspection Report Report Number: 144 For The Property Located On: 123 Any Street 27587 Prepared For Exclusive Use By: Mr. Sample N/A,,, Report Prepared By: Edward Carapezza; License No.: 3447 Inspector

More information

Villa Home Inspections

Villa Home Inspections PROPERTY INSPECTION REPORT SITE INFORMATION Property Address: City, State, Zip: Date of Inspection: Time of Inspection: Parties Present during Inspection: Inspector: Address Omitted. Inglewood, CA 90305.

More information

PROPERTY INSPECTION REPORT

PROPERTY INSPECTION REPORT Burns Home Inspections, LLC 14232 Marsh Lane #262 Addison, Texas 75001 Tel. 972-241-6033 cell 469-644-9429 fax 972-406-9809 E-Mail bb@dfw-inspector.com PROPERTY INSPECTION REPORT Prepared For: Mr. John

More information

Pre-Drywall Inspection Report

Pre-Drywall Inspection Report SM MEDALLION INSPECTIONS helping people make informed decisions Pre-Drywall Inspection Report 5657 Garden Valley Place Milton, Georgia 30024 Prepared for Betsy and Paul Dougherty January12, 2015 Medallion

More information

Cost of Repair Worksheet

Cost of Repair Worksheet Cost of Repair Worksheet Cost of Repair Summary 1 Cosmetic Minor $ 0.00 2 Cosmetic Major + $ 0.00 3 Structural + $ 0.00 4 Fixtures/Appliances + $ 0.00 5 Landscaping + $ 0.00 Contingency Factor + $ 0.00

More information

At Home Inspections Inc. Home Inspection Report 613-267-8979

At Home Inspections Inc. Home Inspection Report 613-267-8979 At Home Inspections Inc. Home Inspection Report 613-267-8979 Inspector's Name Allan Taillefer RHI a member of the Ontario Association of Home Inspectors since 2003. Inspection Number 1505003H Inspection

More information

Inspection Report. provided by: Delaware Property Inspection. Inspector: Richard Hiddemen (302)355-1748

Inspection Report. provided by: Delaware Property Inspection. Inspector: Richard Hiddemen (302)355-1748 Inspection Report provided by: Delaware Property Inspection Inspector: Richard Hiddemen (302)355-1748 ASHI # 243377 DPR #H4-0000018 DDA #06-444 Delaware 1992105842 Wilmington #03857 New Castle #2010-845

More information

Texas Premier Homes LIMITED BUILDER S WARRANTY COVERAGE

Texas Premier Homes LIMITED BUILDER S WARRANTY COVERAGE Texas Premier Homes LIMITED BUILDER S WARRANTY COVERAGE AIR CONDITIONING LIMITED WARRANTY: Performance When air conditioning is included in the home, the system should be capable of maintaining a temperature

More information