DOORS AND WINDOWS V08000
|
|
- Beverly Murphy
- 7 years ago
- Views:
Transcription
1 8.1 GENERAL DESCRIPTION DOORS AND WINDOWS V GENERAL Description This standard identifies minimum requirements that shall be met for all doors, Windows and roof hatches in the design and construction of elements for Arlington County Building Design Standards Related Arlington County Standards, Specification and Policies including, but not limited to, those listed in Table Table Applicable Standards and Specifications Arlington County Policy for Integrated Facility Sustainability - August 19, 2008 ("Green Building" Policy) Applicable Standards and Specifications including, but not limited to, those listed in Table Table Applicable Standards and Specifications American Society for Testing and Materials (ASTM) American with Disabilities Accessibility Guidelines for Public Rights-of-Way (PROWAG) ICC International Building Code/2012 North American Fenestration Standard/Specification for Windows, Doors and Skylights (AAMA/WDMA/CSA 101/I.S.2/A440, NAFS) American National Standards Institute/Builders Hardware Manufacturers Association (ANSI/BHMA): ANSI/BHMA A156.18: Materials and Finishes Builder Hardware Manufacturers Association-(BHMA) US Green Building Council s Leadership in Energy and Environmental Design (LEED) green building rating system Quality Assurance Reserved Submittals The Registered Design Professional shall identify, in the specification sections, manufacturer s products, descriptions, performance criteria, materials, components, fabrication, source quality control, finish, and accessory materials pertaining to all door and window work and construction Windows 8-28 Vertical Infrastructure Document Version
2 8.2.2 DOORS Windows shall be protected with drip caps to keep rain from entering the walls Ths use of steel sash windows is Not Acceptable All new or replacement windows shall utilize thermal-pane glass, with thermo break sash Tbe review by a case-by-case basis for the replacement of windows in a historic Buildings Provide screens for operable windows Protection of Openings: Openings in fire rated barriers shall be protected according to International Building Code, NFPA 80, and NFPA 90A. Doors in such openings shall be normally closed, unless equipped with electromagnetic door hold open devices arranged to close upon activation of the fire alarm system and smoke detectors installed within 15 ft. of both sides of the door. Fire shutters shall be provided to protect openings in fire rated barriers designed to be normally open. Shutters shall be designed to close upon activation of a smoke detectors within 15 ft. of both sides of the shutter. Such detectors shall close all shutters within a fire barrier served. Closing speed shall be in accordance with NFPA 80. Fire dampers shall be installed in fire rated barriers in accordance with NFPA 90A. Fire rating glazing, where used, shall meet applicable safety and fire standards. Note: Shutter includes rolling steel fire doors as well as service counter doors Glazing shall be compatible with the energy modeling of the Building Fire Rated Glazing: The fire rated glazing shall met the requirements for safety glazing in Hazardous locations. Hazardous locations are areas specifically defined in the safety glazing chapter of the Building code, in section As examples, hazardous locations include vision panels in doors, sidelites adjacent to doors, and large fixed panels near walking surfaces. The term area subject to human impact load is broader than the code definition of a hazardous location and is relevant when glazing is used in an athletic facility, gyms, multipurpose rooms used as gyms, and similar types of facilities. These areas shall met CPSC Category II Safety glazing standard. Traditional wired glass will NOT met the requirements of CPSC Category II safety glazing standards Doors Tbe review by a case-by-case basis for the replacement of doors in a historic Buildings Overhead Doors shall be designed with governors and access panels. Additional structural support shall be provided on overhead doors and shall be shown on plans When doors are equipped with automatic openers, the activation shall be hard wired In Fire Houses, access doors for apparatus bays shall be Electric Operated Four Fold Doors. Refer to Building Design Vertical Infrastructure, Chapter 16 - ELECTRICAL - V16000, pg for on Brand Name(s) Category Architectural Door Hardware Panic Hardware should have removable core cylinders to match the Building Master Keying System. Registered Design Professional shall coordinate specification to - Document Version Vertical Infrastructure 8-29
3 8.2.4 KEYING SYSTEM provide ADA Compliant panic hardware to ensure that a minimum door opening width is maintained. Refer to Chapter 8, DOORS AND WINDOWS V08000, Section Architectural Door Hardware pg.8-31 for Brand Name Product(s) All doors shall have floor mounted door stops or wall mounted door stops with adequate blocking in areas that have gypsum wall board Hinges at all doors shall be ball bearing type. Different hinges may be approved for use on a case by case basis New Architectural Door Hardware renovations: for partial renovations, all finished hardware shall match the existing where possible in finish, style and keyway in order to maintain continuity Architectural Door Hardware and materials shall comply with ANSI A Materials and Finishes / BHMA Finishes shall be in accordance with Table ANSI/BHMA Code Keying System Table Architectural Hardware Finish Designations Description Base Material 626 Satin chromium plated Brass, Bronze US26D 630 Satin Stainless Steel Stainless steel US32D 300 series 605 Bright brass, clear Brass US3 coated 613 Dark Oxidized Satin Bronze, Oil Rubbed Bronze US10B Nearest Former U.S. Equivalent The Keying System should be compatible with existing Schlage Master Keying System with C Keyway Registered Design Professional shall coordinate keying schedule with the Arlington County Project Officer, the using agency and Facilities Management Bureau. Contractor shall sort, label, and tag all keys; set up key cabinet with index; and review with the Arlington County Project Officer Registered Design Professional shall coordinate specification to provide Brand Name(s) (manufacturers) standard embossed keys of nickel silver to ensure durability as per Table in the in the following quantities: Table Owner s Project Requirements for Key Quantities Description Grand Master Key Master Keys per set Quantity Per area serviced - 12 each 10 per floor 8-30 Vertical Infrastructure Document Version
4 8.3.1 ARCHITECTURAL DOOR HARDWARE Permanent Control key Refer to Chapter 17 FIRE PROTECTION V17000, Section Key Box pg for additional requirements 12 per level Architectural Door Hardware Brand Name(s) for Building Element in accordance with Table The Specification shall identify a minimum of three (3) Brand Names (manufactures) that comply with the Owner s Project Requirements used for the Invitation to Bid, unless the Brand Name Category listed as. Table Brand Name Product(s) for the Architectural Door Hardware Building Element Door Closers - Floor type - ADA Compliant Brand Name(s) Brand Name Model Rixson Brand Name - Category Door Closers - Floor type Rixson Door Closers - Surface Mounted - ADA Compliant LCN Door Closers - Surface Mounted Finished Hardware-01 Finished Hardware-02 Lockset - ADA Compliant LCN Schlage 'D' Series C Keyway a Corbin CL3300 Series Keyway 4L a Schlage D Series, Rose Design levers a Panic Hardware Von Duprin Note a Finished hardware shall be furnished with Six (6) pin keys and in series unless otherwise indicated in Specifications. - Document Version Vertical Infrastructure 8-31
5 8.3.2 DOORS Doors Brand Name(s) for Building Element in accordance with Table The Specification shall identify a minimum of three (3) Brand Names (manufactures) that comply with the Owner s Project Requirements used for the Invitation to Bid, unless the Brand Name Category listed as. Table Brand Name Product(s) for the Doors Building Element Brand Name(s) Brand Name Model Brand Name - Category Electric Operated Four Fold Doors Door Engineering and Manufacturing, LLC Preferred Manufacturer(s) 8-32 Vertical Infrastructure Document Version
Decorative Lever Designs
Decorative Lever Designs 3 & C 4 & K 12 14 & D 15 & A 16 & B 17 50 51 52 53 54 55 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 2 www.stanleysecuritysolutions.com
More informationAn ASSA ABLOY Group brand. 4800LN Series. Interconnected Locks
An ASSA ABLOY Group brand 4800LN Series Interconnected Locks performance meets style introduction The Yale 4800LN series interconnected locksets combine our key-in-lever locksets with the added safety
More informationBasic Technical Fundamentals of Builders Hardware Mortise, Bored and Auxiliary Locks
Mortise, Bored and Auxiliary Locks Copyright 2002, 2009, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Table of Contents Page SARGENT History...................................................
More informationAutomatic Door Selection Guide
Automatic Door Selection Guide AAADM 1300 Sumner Avenue Cleveland, OH 44115 P: 216-241-7333 F: 216-241-0105 aaadm@aaadm.com Automatic Door Selection Guide General: The members of AAADM manufacture an assortment
More informationSpecifications 7 Line Cylindrical Lever Locks
7 Line Bored Lever Lock Copyright 2003-2015, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Specifications Table of Contents Windstorm Certifications...1 Features, Benefits
More informationthe Company will not warrant ANSI A156.2 Grade 2 lever Product installed in educational facilities and student housing.
product warranties Commercial Applications Limited Warranty Schlage Lock Company, LLC (the Company ) extends a three year limited warranty to the original user of the products manufactured by the Company
More informationDIVISION 08 70 00 HARDWARE FORMAT 1. Technical specifications content and numbering system shall be based on 2004 CSI MasterFormat.
FORMAT 1. Technical specifications content and numbering system shall be based on 2004 CSI MasterFormat. BASIS OF DESIGN 1. APSU design standards shall not replace fully developed, project and market specific
More informationDIVISION 08 70 00 HARDWARE FORMAT 1. Technical specifications content and numbering system shall be based on 2004 CSI MasterFormat.
FORMAT 1. Technical specifications content and numbering system shall be based on 2004 CSI MasterFormat. BASIS OF DESIGN 1. BGSU Design Standards shall not replace fully developed, project and market specific
More informationSECTION 08740 ELECTRO-MECHANICAL HARDWARE
SECTION 08740 ELECTRO-MECHANICAL HARDWARE PART 1 - GENERAL 1.1 SUMMARY: A. Section Includes: 1. Items known commercially as electro-mechanical hardware, required for special applications at limited doors.
More informationCLEAR-DIVISIONS CENTERFOLD
CLEAR-DIVISIONS CENTERFOLD Introduction: The following three (3) part specification offers the Standard and Optional features for the CLEAR-DIVISIONS CENTERFOLD moveable The yellow highlighted areas in
More informationBasic Technical Fundamentals of Builders Hardware
Basic Technical Fundamentals of Builders Hardware Mortise Locks Bored Locks Auxiliary Locks Inside Cover (blank) Table of Contents SARGENT History...4 Basic Name of Products...5, 6 Doors (A Brief Review)...7
More informationCity of San Diego, CWP Guidelines
PART 1 -- GENERAL SECTION 08520-1.1 WORK OF THIS SECTION City of San Diego, CWP Guidelines A. The WORK of this Section includes providing aluminum windows with frames, bracing, glazing attachments, screens,
More informationCLEAR-DIVISIONS VARIOFOLD
CLEAR-DIVISIONS VARIOFOLD Introduction: The following three (3) part specification offers the Standard and Optional features for the CLEAR-DIVISIONS VARIOFOLD moveable The yellow highlighted areas in the
More informationDIVISION 8 DOORS AND WINDOWS
DIVISION 8 DOORS AND WINDOWS A. FINISH HARDWARE AND SPECIALTIES 1. General a. It is the intent of this document to provide guidelines for the Architect's specifications section 08710, finish hardware.
More informationGeneral Fire Code Requirements Within Commercial Tenant Spaces
FIRE DEPARTMENT in cooperation with Scope: General Fire Code Requirements Within Commercial Tenant Spaces This handout is designed to assist owners, architects, contractors and others in understanding
More informationCLEAR-DIVISIONS APERTO
CLEAR-DIVISIONS Introduction: The following three (3) part specification offers the Standard and Optional features for the CLEAR-DIVISIONS moveable glass wall system. The yellow highlighted areas in the
More informationThe replacement or modification of existing windows shall comply with the following requirements:
City of La Habra Heights Building Division 1245 N. Hacienda Road La Habra Heights, CA 90631 Office: (562) 694-6302 ext. 228 Fax: (562) 690-5010 WINDOW REPLACEMENT 2010 CALIFORNIA RESIDENTIAL CODE (CRC)
More informationIntroducing the Schlage NDE series wireless lock with ENGAGE technology
Introducing the Schlage NDE series wireless lock with ENGAGE technology 2 Allegion Engage technology Hello True innovation Strong value Welcome to ENGAGE technology, a new connectivity platform that makes
More informationWhitley Manufacturing Co., Inc. 201 W. First Street S. Whitley, IN 46787 Phone (260) 723-5131 Sales Fax (260) 723-6396 whitley@whitleyman.
Building Type Building Code Whitley Classroom Buildings BOCA, UBC, SBCCI, NEC, ADA Structural Support Outrigger construction standard, Whitley model classrooms. Main support beams to be 12 11.8# per lineal
More informationPDQ HINGE SUGGESTED ARCHITECTURAL SPECIFICATIONS METICULOUSLY MANUFACTURED, THE PDQ HINGE IS AVAILABLE IN 3 BASE METALS: SPECIFICATIONS HINGE SERIES
Commercial Hinges PDQ HINGES PDQ wants to be your total one source supplier of contract hardware materials. The introduction of a high quality PDQ hinge is another step in this direction. PDQ hinges are
More informationSecurity Management System Wiring Diagram Portfolio
Security Management System Wiring Diagram Portfolio SMS Wiring Portfolio Schlage Management System Table of Contents Section 1 Section 2 Section 3 Section 4 Section 5 Section 6 SMS Reader Controller Configurations
More informationA lock for every look.
A lock for every look. Welcome keyless. Keys, your number is up. With Schlage Touch, no key means there s nothing to lose, nothing to fiddle with, and for intruders nothing to pick. All in a slim profile
More informationAutomatic Door Openers and ADA Devices Rev. 0 Bid # 48240056. Scope of Work
Scope of Work I. Scope of Solicitation II. Instructions to Offerors III. Scope of Work / Specifications IV. Terms and Conditions - Special I. SCOPE OF SOLICITATION Clemson is seeking to initiate a turnkey
More informationLift-off hinge. Rising hinge. Standard hinge. Heavy duty hinge. Parliament hinge. Spring hinge. Double action spring hinge. Concealed mortise hinge...
Door Hinges Contents Butt hinges Lift-off hinge Rising hinge Standard hinge Heavy duty hinge Parliament hinge Spring hinge Double action spring hinge Concealed hinges Concealed mortise hinge... Pivot
More informationSECTION 6. Glass Storefront Doors:
SECTION 6 Glass Storefront Doors: Table of Contents 3070 Storefront Door System Description & Dimensions 6070 Storefront Door System Description & Dimensions Door Leaf Detail Optional 10 Bottom Rail Detail
More informationFloor-Concealed Door Closers with Electromagnetic Hydraulic Hold Open DORMA BTS80 EMB
Floor-Concealed Door Closers with Electromagnetic Hydraulic Hold Open DORMA BTS80 EMB Floor-Concealed Door Closers with Electromagnetic Hydraulic Hold Open Aesthetically Pleasing Floor Closer for Fire/Life
More informationNanaWall SL73 - Thermally Broken Aluminum Framed Hurricane Rated Folding System with Miami Dade County, Florida NOA
NanaWall SL73 - Thermally Broken Aluminum Framed Hurricane Rated Folding System with Miami Dade County, Florida NOA ❶ PART 1 - GENERAL 1.01 SUMMARY A. Section Includes: Sliding/folding aluminum and glass
More informationStandard Door Specification
Element General Requirement To be defined in the project brief but should meet Building Regulations. All doors to be a minimum of 30 minute fire rated and must comply with all relevant UK legislation and
More informationSECTION 17400 ACCESS CONTROL SYSTEM. CONDITIONS OF THE CONTRACT AND DIVISION 1, as applicable, apply to this Section.
SECTION 17400 ACCESS CONTROL SYSTEM CONDITIONS OF THE CONTRACT AND DIVISION 1, as applicable, apply to this Section. PART 1 - GENERAL 1.1 RELATED WORK A. 16060 Grounding and Bonding B. 16070 Electrical
More informationSECTION 08360 SECTIONAL OVERHEAD DOORS 521 SERIES ALUMINUM SECTIONAL OVERHEAD DOORS
SECTION 08360 SECTIONAL OVERHEAD DOORS 521 SERIES ALUMINUM SECTIONAL OVERHEAD DOORS Display hidden notes to specifier by using Tools / Options / View / Hidden Text. On newer versions of Microsoft Word
More informationA ROAD MAP FOR YOUR CODE, SMOKE BARRIER & SMOKE PARTITION REQUIREMENTS
A ROAD MAP FOR YOUR CODE, SMOKE BARRIER & SMOKE PARTITION REQUIREMENTS International Code Council National Fire Protection Association Underwriters Laboratories Inc. 5203 Leesburg Pike, Suite 600 1 Batterymarch
More informationMEANS OF EXIT / ESCAPE / EGRESS SELF INSPECTION CHECKLIST
OPTIONAL INFORMATION Name of School: Date of Inspection: Vocational Program/Course/Room: Signature of Inspector: MEANS OF EXIT / ESCAPE / EGRESS Guidelines: This checklist covers some of the regulations
More informationArchitectural Casework 06400-01. 1.01 Description of Work
06400-01 1.01 Description of Work A. Extent of each type of architectural millwork and casework as indicated on drawings. Types of architectural casework shall include both stained and plastic laminated
More information280+ Mortise Mounted Series Shear Locks Special Application Solution
280+ Mortise Mounted Series Shear Locks Power Plus control module overcomes gaps of up to 1/4" Low Temperature Operation 280+ TRD Locknetics provides the industry s most complete selection of electromagnetic
More informationFire-Rated Doors and Hardware. A Guide to Field Inspection
Fire-Rated Doors and Hardware A Guide to Field Inspection Foundation s Mission To promote secure and safe openings that enhance life safety Awareness To be a source of information through awareness campaign
More informationWelcome to the AccessibilityOnline Webinar Series. A collaborative program between the National Network of ADA Centers and the. U.S.
Welcome to the AccessibilityOnline Webinar Series A collaborative program between the National Network of ADA Centers and the US Access Board The Session is Scheduled to begin at 2:30pm Eastern Time We
More informationFloor-Concealed Door Closers DORMA BTS80
Floor-Concealed Door Closers DORMA BTS80 Floor-Concealed Door Closers Dependable and Versatile Floor-Concealed Closer The BTS80 Series of floor-concealed door closers offer adaptability to almost any installation.
More informationNEWSTAR BROCHURE. December 2007
NEWSTAR BROCHURE December 2007 Surface Overhead Door Closers Door Closing 5003 Silver Slide Cover SE Door Widths from 850mm to 1100mm. Door Weights 40kg to 80kg. Suitable for use in temperatures from -15
More informationProduct Finishes Guide. More for your door than any other brand.
Product Finishes Guide More for your door than any other brand. Architectural Door Hardware Finishes From classic to contemporary, you ll find a complete range of door hardware finishes available at Hager,
More informationOffice of the State Fire Marshal. Fire Rated Doors
Office of the State Fire Marshal Fire Rated Doors Fire Rated Doors These doors serve a purpose. They are manufactured in a way that is to help reduce the spread of fire and smoke. Fire rated doors allow
More informationCluster Box Units. (CBU s) 3300 Series CBU Door Sizes. Fully Integrated Parcel Lockers CLUSTER BOX UNITS FRONT LOADING. continued on pages 7-11
Cluster Box Units (CBU s) continued on pages 7-11 CLUSTER BOX UNITS FRONT LOADING Made of heavy duty aluminum and stainless steel hardware, Salsbury 3300 series U.S.P.S. approved Cluster Box Units (CBU
More informationDivision 8 Doors & Windows
Division 8 Doors & Windows 08050 Basic Door and Window Materials and Methods 1. Has a minimum door leaf size of 3-0 x 7-0 been specified for both interior and exterior doors? 2. Has the door height been
More informationIrvinton Village Apartments 2901 Fulton Houston, Texas 77009 Houston Housing Authority J. Allen Management Managing Agent
Irvinton Village Apartments 2901 Fulton Houston, Texas 77009 Houston Housing Authority J. Allen Management Managing Agent Scope for Irvinton Village Unit #512 Overall Scope: Demolition, Renovation, and
More informationCHECKLIST FOR DOOR HARDWARE
CHECKLIST FOR DOOR HARDWARE HINGES: Except for residential and light commercial use all hinges should be ball-bearing/oil impregnated type Hinges on exterior doors should be non-ferrous with non-removable
More informationSECTION 13850 (28 31 00) FIRE DETECTION AND ALARM SYSTEM
SECTION 13850 (28 31 00) FIRE DETECTION AND ALARM SYSTEM ENGINEERING SPECIFICATION INTELLIGENT REPORTING FIRE DETECTION SYSTEM PART 1 GENERAL 1.1 DESCRIPTION A. This specification includes the furnishing,
More informationRTS88. Overhead Concealed Door Closer
RTS88 Overhead Concealed Door Closer RTS88 OVERHEAD CONCEALED CLOSER DORMA RTS88 OVERHEAD CONCEALED DOOR CLOSER Invisible door control Dependable and easy to install Architects are often challenged to
More informationOriginal Document 10/16/07 Revised 01/30/09 2 nd Revision 01-23-12 3 rd Revision- 12/18/14
North Collier Fire Control & Rescue District Greater Naples Fire Rescue District Immokalee Fire Control & Rescue District 2800 North Horseshoe Drive Naples, Florida 34104 SYSTEM REHABILITATION PLAN CHECKLIST
More informationCONCEALED BEARING HINGES. StANLEy ARCHItECtuRAL HARDwARE
CONCEALED BEARING HINGES StANLEy ARCHItECtuRAL HARDwARE STANLEY ARCHITECTURAL HARDWARE TABLE OF CONTENTS Page Table of contents...2 Company history...2 5 knuckle concealed bearing design...3 Full mortise
More informationTable of Contents PART 1 WINDOW SELECTION GUIDE. Window and Door Selection Guide
VOLUME 1 - WINDOWS AND DOORS Window and Door Selection Guide PART 1 WINDOW SELECTION GUIDE WSG-11 PART 2 - PERFORMANCE SPECIFICATIONS Voluntary Specifications for Aluminum, Vinyl (PVC) and Wood Windows
More informationBASIC FIRE DOOR REQUIREMENTS TECHNICAL DATA SHEET NO. 401
BASIC FIRE DOOR REQUIREMENTS SHEET NO. 401 Fire door openings are classified by their locations in the building. The location determines the length of exposure protection required, based on the potential
More informationquality door and window systems for metal buildings
quality door and window systems for metal buildings knock-down door systems Features and Benefits: Galvanized Doors and Frames Insulated Door Cores Textured Steel Door Faces Completely Reversible (non-handed
More informationILCO Cylinders. Cams and Tailpieces. Keyways. Finish Codes. 1 Standard (863G) Composite NB HR1. Composite NA R1064E. 2 Adams Rite (863A) Arrow AA 1179
Keyways Cams and Tailpieces Arrow AA 1179 Composite NA R1064E Composite NB HR1 1 Standard (863G) 2 Adams Rite (863A) Corbin 60 CA 1001EH Corbin CD 59A1-A2 Dominion DA S54F UB Lori L100 Eagle 11929 Harloc
More information2301.1 Scope: Communications and Electronic Systems addressed in this section include:
Chapter 23 COMMUNICATIONS / ELECTRONIC SYSTEMS SECTION 2301 - GENERAL 2301.1 Scope: Communications and Electronic Systems addressed in this section include: 1. Fire Alarm System 2. Telecommunication and
More informationAndersen Clad Inswing Entry Doors (2001 to Present)
Andersen Clad Inswing Entry Doors (2001 to Present) What s in This Section Clad Inswing Entry Doors Page 3 Part Illustrations 3 Parts Illustration - Single Door 3 Parts Illustration - Double Door 4 Parts
More informationDor-O-Matic Exit Devices
Dor-O-Matic Exit Devices THE FALCON DIFFERENCE S A F E T Y, S E C U R I T Y A N D U N C O M P R O M I S I N G V A L U E At Falcon, we know that every product you sell not only has to meet local building
More informationELECTRICAL CONTRACTORS THE UNIVERSITY OF TENNESSEE KNOXVILLE, TENNESSEE SECTION 16050 PAGE 1
KNOXVILLE, TENNESSEE SECTION 16050 PAGE 1 PART 1 - GENERAL 1.01 RELATED DOCUMENTS: SECTION 16050 A. Drawings and general provisions of Contract, including General and Supplementary Conditions and Division-1
More informationPhoenix-3W Series One-Way Security Revolving Doors
Phoenix-3W Series One-Way Security Revolving Doors ONE-WAY SECURITY REVOLVING DOOR SPECIFICATIONS ARCHITECTURAL SPECIFICATIONS Phoenix-3W Series One-Way Security Revolving Door Division 8 Doors and Windows
More informationNC State University Design and Construction Guidelines Division 26 Fire Alarm Systems
NC State University Design and Construction Guidelines Division 26 Fire Alarm Systems 1.0 Purpose A. The following guideline provides the minimum standards and requirements for fire alarm systems. 2.0
More informationRADAR. 227 www.ncdirect.co.uk
RADAR solutions RADAR RADAR Key System 228 RADAR Lockset 229 RADAR Cover Plate 229 RADAR Padlock 230 RADAR Automatic Toilet Entry System 231 RADAR Ramp 231 RADAR Ramp Sign 231 227 www.ncdirect.co.uk RADAR
More information10 Line. Cylindrical Lever Locks
10 Line Cylindrical Lever Locks Copyright 2004-2009, 2011, 2013-2015 Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Table of Contents Windstorm Certifications...1 Features
More informationGarden Windows Builders Vinyl
TABLE OF CONTENTS Specifications... 8-2 QuickSpecGuide... 8-3 Elevations/Sizes: 1/4 Scale GardenUnits... 8-4 Grille Patterns... 8-5 SectionDetails: 6 Scale... 8-6 December 2008 JELD-WEN reserves the right
More information5300 Series. Description: Grade 1 Heavy Duty Surface Door Closer Ideal for schools, hospitals, and other high-use environments
5300 Series Description: Grade 1 Heavy Duty Surface Door Closer Ideal for schools, hospitals, and other high-use environments Certifications - BHMA Certified ANSI A156.4, adjustable sizes Arms & Brackets
More informationNarrow stile lock 1314
3 2 4 6 6 1 3 2 4 4 5 3 2 4 3 5.... ( (. ). ) 11 12 5 3 5 4 8 1 6 20 8.5 6.5 19 Backset 15 3 5 2 1 5 2 5 5 0 8 9 2 8 1 1 21-1mm 12 8 24 1 6 8 1 ( 9 2 5 ) ) ). ) Narrow stile lock 1314 CE EN 12209 2 4 5
More informationCabinet Locks. Benefits:
Cabinet Locks Medeco high security cabinet locks are specifically designed for drawer or cabinet door applications where a conventional utility cam lock may not be suitable. Cabinet locks utilize heavy-duty
More informationThis directive establishes Department of Homeland Security (DHS) policy regarding the physical protection of facilities and real property.
Department of Homeland Security Management Directives System MD Number: 11030.1 Issue Date: 04/21/2003 PHYSICAL PROTECTION OF FACILITIES AND REAL PROPERTY I. Purpose This directive establishes Department
More informationFIRE/LIFE SAFETY CLOSERS/HOLDERS SERIES
FIRE/LIFE SAFETY CLOSERS/HOLDERS SERIES PRODUCT SELECTION GUIDE SENTRONIC Series LCN closer/holders combine heavy duty closers with electrically controlled hold-open functions to control fire and smoke
More informationwestern transforming space window systems series 670 a new option for hinged window line
western window systems a new option for transforming space series 670 hinged window line Western Window Systems a new way to live, a better way to build Since opening in 1959 in Phoenix, Western Window
More informationINC Flexi-Sorb. Versatile Flexible Easy To Install Durable Good Noise Reduction Economical. Typical Applications
INC Flexi-Sorb Noise Control Curtain System Versatile Flexible Easy To Install Durable Good Noise Reduction Economical Our Flexi-Sorb noise control curtain product line consists of flexible, durable acoustical
More informationSECTION 23 00 01 HEATING, VENTILATION AND AIR CONDITIONING EQUIPMENT
SECTION 23 00 01 HEATING, VENTILATION AND AIR CONDITIONING EQUIPMENT PART 1 - GENERAL 1.1 DESCRIPTION A. The Work specified in this Section consists of designing, furnishing and installing factory-assembled
More informationDIVISION 00 - PROCUREMENT AND CONTRACTING REQUIREMENTS
DIVISION 00 - PROCUREMENT AND CONTRACTING REQUIREMENTS NOTICE TO BIDDERS BID FORM INSTRUCTIONS TO BIDDERS CONTRACTOR S BID FOR PUBLIC WORK - FORM 96 MINORITY AND WOMEN S BUSINESS ENTERPRISE PARTICIPATION
More informationINSTALLATION GUIDELINES for SOLAR PHOTOVOLTAIC SYSTEMS 1
City of Cotati Building Division 201 W. Sierra Ave. Cotati, CA 94931 707 665-3637 Fax 792-4604 INSTALLATION GUIDELINES for SOLAR PHOTOVOLTAIC SYSTEMS 1 Any PV system on a new structures should be included
More informationKITCHEN AND BATH REMODELING BUILDING PERMIT REQUIREMENTS
St. Louis County Department of Public Works Division of Code Enforcement KITCHEN AND BATH REMODELING BUILDING PERMIT REQUIREMENTS This guideline is intended to provide the homeowner/contractor with the
More informationInstallation Instructions and Ordering Information
The Flush Finish Trimless Door Frame Installation Instructions and Ordering Information CLEAN LINES! The Flush Finish Door Jamb System Manufactured by STUDCO Building Systems Step 1 Verify if you are using
More informationSafe schools. Security solutions
Safe schools Security solutions Frequently Asked Questions How can a hardware manufacturer know how to make my school safer? Because we have already identified potential problems specific to schools through
More informationSierra Pacific Windows
Sierra Pacific Windows Bi-Fold Windows & Doors Sierra Pacific Bi-fold Windows and Doors glide smoothly to create large openings that transform your living spaces. With panels folding and stacking either
More informationIntroducing the Schlage NDE series wireless lock with ENGAGE technology
Introducing the Schlage NDE series wireless lock with ENGAGE technology 2 Allegion Engage technology Hello True innovation Strong value Welcome to ENGAGE technology, a new connectivity platform that makes
More informationDENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION 17650 SECURITY SYSTEMS
PART 0 DESIGN STANDARDS 0.01 GENERAL DESIGN GUIDELINES A. Inspections and observations by the Owner do not relieve the A/E of contract responsibilities. B. Chain of command 1. The DPS Project Manager is
More information2006-2007 Safeguard Storm Doors Beauty, the security of advanced design, and the guarantee of a lifetime.*
2006-2007 Safeguard Storm Doors Beauty, the security of advanced design, and the guarantee of a lifetime.* 6 Designs To choose! Like all classic designs, Elite embraces balance and proportion while using
More informationSECTION REFERENCE. Tilt-Wash Double-Hung. Insert Windows. 400 Series
SECTION REFERENCE Size Ranges... 96 Existing Window Measurements... 96 Divided Light Patterns... 97 Window Details... 97 Joining Details... 97 Performance Data... 269 400 Series Windows TILT-WASH DOUBLE-HUNG
More informationGlass. Pre-Assembled Glass Entry Doors. In Stock Models Available! 1-800-486-8415
Glass Store Front Doors 1-800-486-8415 www.glassstorefrontdoors.com Pre-Assembled Glass Entry Doors Commercial Glass Store Front Doors Pre-Assembled and Ready for Quick Install In Stock Models Available!
More informationBasic Fire Door Requirements
TECHNICAL DATA SERIES S D I 118-01 Basic Fire Door Requirements 2001 Steel Door Institute STEEL DOOR INSTITUTE 30200 DETROIT ROAD - CLEVELAND, OHIO 44145 Technical Data Series SDI 118-2001 Basic Fire Door
More informationSliding Door Hardware Bi-fold By-Pass Pocket
Sliding Door Hardware Bi-fold By-Pass Pocket Sliding Door Hardware The John Sterling Sliding Door Hardware products offer a complete line of hardware for interior sliding Bi-Fold doors, By-Pass doors,
More informationWalking and Working Surface Checklist:
Walking and Working Surfaces Purpose: This information is presented to improve the level of safety in our operations, and to inform you that we will comply with the OSHA Standard 29 CFR 1910.23. Responsibility:
More informationVOLUME V GUIDELINES FOR DESIGN CONSULTANT TABLE OF CONTENTS APPENDIX B: MASTER CONSTRUCTION SPECIFICATIONS AND PREPARATION GUIDE, DIVISIONS 0-10
VOLUME V GUIDELINES FOR DESIGN CONSULTANT TABLE OF CONTENTS APPENDIX B: MASTER CONSTRUCTION SPECIFICATIONS AND PREPARATION GUIDE, DIVISIONS 0-10 SECTION B1: PREPARATION GUIDE B1.1 INTRODUCTION... B1-1
More informationName Of Occupancy Date. Yes No Describe
FIRE PREVENTION INSPECTION CHECKLIST For Class A Occupancy (For Assembly Buildings, Bars, Restaurants, Gyms, Churches, Arenas, Theatres or wherever people gather) Name Of Occupancy Date Physical Address
More informationSECTION 08332 COILING COUNTER DOORS. Display hidden notes to specifier. (Don't know how? Click Here)
SECTION 08332 COILING COUNTER DOORS Display hidden notes to specifier. (Don't know how? Click Here) PART 1 GENERAL 1.1 SECTION INCLUDES A. Coiling Metal Counter Doors. B. Coiling Counter Fire Doors. 1.2
More informationClassroom Door Security & Locking Hardware
Classroom Door Security & Locking Hardware The ability to protect students and teachers while in the classroom is a high priority in all educational institutions. Many schools and school districts have
More informationElectromagnetic locks
Electromagnetic locks Electromagnetic locks from Schlage Schlage has a rich heritage in electronic security. For years we have led the industry by providing a broad portfolio of solutions to meet the diverse
More informationSolar Panel Installations
Solar Panel Installations Page 1 of 6 SINGLE-FAMILY RESIDENTIAL CHECKLIST City of Hayward Development Services Department Revised: 7-09-15 PERMIT REQUIREMENTS Permits are required for all solar panel installations.
More informationArchitectural hardware consulting services
Architectural hardware consulting services Architectural hardware consulting services Door hardware may only be a small percentage of the cost of the design and construction process, but it encompasses
More information88 Series Rim Exit Device. Service manual
88 Series Rim Exit Device Service manual INDEX General Information Introduction... How to Order... Part Number Changes... 88 Rim Series Finishes... 3 Outside Trim Functions... 3 Strikes... 3 88 Rim Series
More informationUnderstanding Access Control
Understanding Access Control To understand access control, we must understand the language of the industry. Terms like alarm inputs, relays, timezones, anti-passback, shunt, and access levels are commonly
More informationSECTION 22 42 00 COMMERCIAL PLUMBING FIXTURES
SECTION 22 42 00 COMMERCIAL PLUMBING FIXTURES PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification
More informationCHAPTER 24 GLASS AND GLAZING
CHAPTER 24 GLASS AND GLAZING SECTION 2401 GENERAL 2401.1 Scope. The provisions of this chapter shall govern the materials, design, construction and quality of glass, lighttransmitting ceramic and light-transmitting
More informationCISA esigno Contactless Lock
CISA esigno Contactless Lock Innovative Security Solution for Hotels & Resorts Seamless Contactless Wireless esigno Contactless lock CISA esigno is the latest addition to our range of security solutions
More informationThe Pennsylvania State University ------------- Physical Security Office. Intrusion Alarm. Performance Specification
The Pennsylvania State University ------------- Physical Security Office Intrusion Alarm Performance Specification By PHYSICAL SECURITY OFFICE Group (Access Controls & Electronic Security Programs) and
More informationGuideline for Fire Safety Elements of Solar Photovoltaic Systems July 17, 2008 Rev: 1/1/10
Guideline for Fire Safety Elements of Solar Photovoltaic Systems July 17, 2008 Rev: 1/1/10 This document was developed by the Orange County Fire Chiefs Association, Orange County Fire Marshal Committee.
More informationPRODUCT INTRODUCTION PRECISION HARDWARE
PRODUCT INTRODUCTION PRECISION HARDWARE INTRODUCTION INTRODUCTION Originally located in southeastern Michigan, Precision Hardware has been manufacturing panic and fire exit hardware for over a half century.
More information2.02. Specifications. General. Products. Execution. Offset Pivots P-694 Top and Bottom Pivots
2.02 Standard Specifications General Entrances Description Furnish all necessary materials, labor and equipment for the complete installation of aluminum entrance doors, door frames and hardware as shown
More informationCustomized Server Cabinets
GOING GREEN WITH CUSTOMIZABLE CABINETS AND RACKS Designed to provide industry leading airflow, CyrusOne s cabinets and rack solutions promote optimal cooling and contribute to reduced power consumption.
More information