A root and branch review of Standards Chapter 4.2 An introduction to the significant changes in the Chapter rewrite.

Size: px
Start display at page:

Download "A root and branch review of Standards Chapter 4.2 An introduction to the significant changes in the Chapter rewrite."

Transcription

1 NHBC s technical newsletter April 2003 Issue 26 This edition includes: A root and branch review of Standards Chapter 4.2 An introduction to the significant changes in the Chapter rewrite. Concrete changes to Chapter 2.1 A better understanding of concrete and chemical attack leads to a Chapter update. New guidance for underfloor heating systems NHBC introduces guidance on the design and installation of these systems. Changes to Part E of the Building Regulations A summary of the changes to regulations governing sound insulation. NHBC gives support to the joist debate We evaluate the two methods used for the support of floor joists. EXTRA STANDARDS EXTRA 1

2 CONTENTS 2 A root and branch review of Chapter Concrete changes to Chapter NHBC publishes Good Craftsmanship Guides 3 NHBC launches Trade Talks 4 Adequate fixings for tiles and slates A root and branch review of Chapter 4.2 One of the major areas of claim against Buildmark is foundation failure. All too often these claims involve homes which have been constructed on shrinkable clay soil in close proximity to trees or shrubs. 4 New guidance for underfloor heating systems 5 Changes to Part E of the Building Regulations 6 NHBC gives support to the joist debate 7 Reminder - Notification of energy ratings 8 Questions and Answers Shrinkable clays change in volume as their moisture content varies. This can result in subsidence or heave to the home where the tree causes the moisture content to vary and the foundations have not been designed to take account of the possible movement. The problems associated with clay soils were highlighted in the late '60s when NHBC first published Practice Note 3 which provided guidance to avoid damage caused by trees near dwellings. This was revised in 1974 and again in This version subsequently became Chapter 4.2 of the Standards, which was itself revised in Over the years our knowledge of the way in which trees and foundations interact has increased and the time has come to review the Chapter again. This review has been based on both our claims data and up-to-date advice from engineers and arboriculturalists. The 2003 version expands the guidance to include shrubs. NHBC Claims data confirms that some claims are caused by shrubs; Pyracantha, Cotoneaster and climbers such as Ivy, Virginia Creeper and Wisteria can be particularly damaging. The guidance asks for minimum foundation depths to be increased where shrubs are planted unless they are excluded within stated distances from the foundation. Other changes include: the addition of an introduction to explain the philosophy behind Chapter 4.2 better guidance about where heave is likely to occur guidance about the Plasticity Index of shrinkable clay soils limitations on the maximum depths of trench fill foundations - where they are greater than 2.5m deep then an engineer will need to become involved. This is because of the uncertainty of such foundations at these depths. The actual foundation depths given in the Chapter remain unchanged. However, the graphical solution to finding the correct foundation depth has been improved. The alternative method by use of tables has also been improved by combining tables. A D/H table has been included so it is no longer necessary to work this out when determining foundation depths. A number of tree species have been added and two species have been changed to a higher water demand category. Hawthorn has been moved from Moderate to High and Beech has been moved from Low to Moderate. The Chapter will become effective for homes where the foundations are commenced on or after 1 July Familiarise yourself with the new Chapter. If you have used very deep trench fill foundations in the past, then these will not be acceptable in the future unless they are designed by an Engineer. 2 STANDARDS EXTRA

3 Concrete changes to Chapter 2.1 Image courtesy of RMC UK Familiarise yourself with the new Chapter and ensure that the correct grade of concrete is specified. Ready mixed suppliers are gearing up to supply the new mixes. NHBC Standards Chapter Concrete and its Reinforcement - has been revised to take account of the better understanding of concrete specification needed to resist chemical attack from the ground, as detailed in the new BRE Special Digest 1, (see page 7 of Standards Extra 23). In addition, the revisions bring the Chapter in line with the European Standard for concrete, BS EN 206-1, and its complementary British Standard, BS 8500-Parts 1 and 2. In December 2003 these Standards will replace the current British Standard for concrete, BS 5328 which was revised in September 2002 to take account of BRE Special Digest 1. The revised NHBC Chapter lists Designated mixes which are supplied ready mixed or Standard Prescribed mixes for site mixing which are suitable for non-aggressive and the lower range of ground chemical aggressiveness. Specialist advice is required for the more aggressive ground environments because a range of items needs to be considered before the concrete can be specified. These include: whether the ground water is static or mobile whether the ground water is acidic or not whether the site is brownfield or natural the size and service life of the structural elements what aggregates are to be used in the concrete whether additional protective measures are to be applied to the concrete e.g. protective coatings or sacrificial layers. In general terms a concrete that satisfied the requirements of Class 1 or Class 2 sulfate conditions under the old BRE Digest 363 is also likely to satisfy the ACEC (Aggressive Chemical Environment for Concrete) Classes 1 and 2 as shown in table 4b, Appendix B of the Chapter. The revised Standards Chapter 2.1 is effective from July NHBC publishes Good Craftsmanship Guides Enclosed with this issue of Standards Extra are Good Craftsmanship Guides for: Brickwork and Blockwork, and Carpentry and Joinery Carcassing These easy-to-use booklets are practical reference guides, which use photographs and illustrations to highlight common pitfalls and provide advice on avoiding them. The problems are those most often identified during NHBC s inspection of homes under construction. All of the photographs were taken on real building sites. Further copies of the Good Craftsmanship Guides are available from NHBC Distribution (phone , fax ) at for 50 copies (including postage & packing). Building Inspectors hold a limited number of copies and may be able to provide small quantities, on request, during scheduled visits to your sites. NHBC launches Trade Talks NHBC has recently launched its troubleshooting Trade Talks for site tradespeople. Based on the NHBC Standards and delivered by NHBC Building Inspectors, these one-hour talks are designed to highlight the most common reportable items or defects encountered by inspectors and claims investigators on residential developments. Practical guidance is then given on how to prevent these problems. The emphasis is on preventing defects through getting it right first time. This type of training will help cut costs in terms of repair work, and will also have a positive impact on customer satisfaction and the levels of aftercare service needed to manage problems. Everyone who attends a Trade Talk will receive his or her own copy of the relevant NHBC Good Craftsmanship Guide. We are currently offering Trade Talks on the following subject areas: Brickwork and Blockwork, and Carpentry and Joinery Carcassing Trade Talks can be delivered on or near your site, provided that a suitable room is available to seat the attendees. Cost is VAT per Talk for a maximum of 12 attendees. A 10% discount is offered for two or more Talks run consecutively at the same venue. Bookings can be made by calling Lisa Jones on STANDARDS EXTRA 3

4 Adequate fixings for tiles and slates Some readers may have seen press articles about the need for extra fixings for tiles and slates. These have come about because of changes to the British Standards dealing with roofing (BS Code of practice for slating and tiling) and wind loading (BS Code of practice for wind loads). The effect of these changes is that fixings arrangements are now different. This is due to the way wind loads are calculated and applied to different tiles, different roof configurations and geographical location of the site. How can builders be sure they are providing an adequate number of fixings? Tile manufacturers we have spoken to provide a free design service. They have computer programmes to determine wind pressures for a specific location. From that information, they can specify the number of fixings for the tiles. Image courtesy of Redland Roofing Ensure that your specification for fixing roofing tiles and slates meets with BS 5534 and BS 6399 for each site. It is necessary to have each location checked, as fixing requirements will vary. New guidance for underfloor heating systems Underfloor heating systems may not be widely used in mainstream house building but they are popular with certain sectors of the industry. Underfloor heating systems need to be designed and installed carefully to ensure they are capable of heating the home in accordance with NHBC s requirements. As the heat output is determined by the length of the heating loop, systems which fail to work correctly cannot be put right simply by fitting a larger radiator. Extending the heating loop is bound to involve major upheaval to the property. The Building Services Research and Information Association (BSRIA) has recently completed a project looking at underfloor heating systems. This has culminated in the publication of two guides one for designers and the other for the assessment of installations. NHBC Standards Chapter 8.1 now recognises these two publications where underfloor heating is proposed. By following the guides, it will ensure that a consistent approach is adopted by system designers and installers and systems meet home owners expectations. Image courtesy of Wavin UK If you are proposing to use an underfloor heating system, then ensure it meets with the BSRIA guides, both in terms of the design and installation. Copies are available from BSRIA, Old Bracknell Lane West, Bracknell, Berkshire, RG12 7AH. Tel: Fax: bsria@bsria.co.uk 4 STANDARDS EXTRA

5 Changes to Part E of the Building Regulations The Government has introduced changes to Part E of the Building Regulations (England & Wales), which currently sets the standard for sound insulation between dwellings. The new regulations are designed to improve the standard of sound insulation in dwellings and have been extended to encompass other building types such as 'rooms for residential purposes' (e.g. hostels and hotels), and schools. The proposals are also backed up by new requirements for sound testing. What are the changes? In summary the significant changes are: Improvement of sound insulation between dwellings and between 'rooms for residential purposes' by: setting a new performance standard for separating walls and floors that takes greater account of low frequency noise promotion of substantial constructions more likely to comply with the new standard introduction of mandatory sound testing to prove compliance of each construction type used (see sound testing ). Improvement of sound insulation within dwellings and 'rooms for residential purposes' by: controlling sound insulation between bedrooms and rooms containing wcs and other rooms controlling sound insulation of internal floors. Limiting reverberation in common parts of buildings containing flats or 'rooms for residential purposes' by: designing the common parts of buildings to prevent excessive reverberation (e.g. by providing acoustic ceiling linings). When? The new Part E comes into effect for all relevant building work from 1 July Sound testing For new houses and flats the requirements for sound testing come into effect on 1 January For converted houses and flats and new and converted 'rooms for residential purposes' the requirement for sound testing comes into effect on 1 July From then at least one set of pre-completion tests will need to be carried out for each ten units. Builders should be aware that the new provisions will not apply where work on a plot has started, or a Plans Certificate for the work has been issued by NHBC or unconditional plans approval has been given by the Local Authority prior to 1 July The following table provides additional clarification as to which regulations apply where work is commenced on individual buildings on or after 1 July Plans Certificate* not issued prior to 01/07/2003 Plans Certificate* not issued prior to 01/07/2003 New build dwellings and flats Plans certificate* for work issued prior to 1 July 2003 Individual buildings commenced prior to 1 July 2003 Individual buildings commenced on or after 1 July 2003 and prior to 1 January 2004 Conversions and rooms for residential purposes * Plans certificate issued by NHBC Building Control or unconditional plans approval issued by Local Authority Building Control. Robust Standard Details Pre-completion sound testing will not be required for new homes until 1 January This delay is to allow the industry the opportunity to develop Robust Standard Details. A major House Builders Federation (HBF) project is currently underway to develop forms of separating wall and separating floor constructions, which provide consistently Approved Document E applicable Sound testing required Individual buildings commenced on or after 1 January 2004 Approved Document E applicable Sound testing required Plans certificate* for work issued prior to 1 July 2003 Individual buildings commenced prior to 1 July 2003 Individual buildings commenced on or after 1 July 2003 good performance and so will not need testing. Given that the project is successful, builders will be able to choose between building in accordance with the Robust Standard Details or undertaking sound testing. Further information on the HBF project is available by visiting STANDARDS EXTRA 5

6 NHBC gives support to the joist debate A hot topic at the moment is the support of floor joists. Here we look at two alternative methods of support in masonry construction. Each method needs to be carefully considered for very different reasons. The first part of this article confirms the correct use of joist hangers. The second part details one method of building-in joists, which satisfies Part L1 of the Building Regulations (England & Wales). We also look briefly at the implications of the new Part E with respect to the building-in of joists. 1 Support of joists using joist hangers The Health and Safety Executive (HSE) has expressed concern that unless hangers are used correctly, there is a potential risk of floor collapse during construction. This is not a new issue and NHBC highlighted the problem in 1997 in Standards Extra 14. However, HSE has asked NHBC to remind registered builders of the need to use hangers correctly because they have had to continue investigating incidents where floors have collapsed. When using joist hangers:- use joist hangers that comply with BS 6178 Part 1, 1999* obtain and follow the manufacturer s installation requirements ensure that the hangers and blocks are compatible. Do not use hangers marked for use with a particular block strength on blocks of a lower strength, eg. don t use 3.5N/mm 2 hangers on 2.8 N/mm 2 blocks ensure that the hanger back-plates are flush to the wall and that the hangers are vertical ensure joists are cut to length with a maximum overall tolerance of 6mm do not load the joists until the required number of courses have been laid above the masonry flanges (usually 3 block courses but consult the hanger manufacturer) and the mortar joints have achieved the required strength. Alternatively install an engineer designed support system under the joists and have it checked before loading the floor. 2 Building-in of joists In England and Wales the Robust Details, which support Approved Document L1, show timber floor joists supported by joist hangers rather than being built into a masonry wall. This is to reduce air leakage at the junction of the two elements. The Building Regulations in England and Wales are performance based. Therefore, alternatives are acceptable if they meet with the performance standard. NHBC has considered a number of proposals for the building-in of joists into a cavity wall. The following alternatives are acceptable. Solid timber joists Solid timber joists may be built into the inner leaf of a cavity wall, provided that: the mortar joints around each joist perimeter are recessed or struck, and the joint between the masonry and the timber is carefully pointed with silicone mastic: (*The above guidance is based on hangers which meet with BS A new European Standard (BS EN 845-1) is available and some manufacturers may be producing hangers to this standard. If this is the case, check the manufacturer s recommendations about use.) Bead of sealant applied between wall and joist 6 STANDARDS EXTRA

7 Timber engineered joists Timber engineered joists may be built into the inner leaf of a cavity wall, provided that: proprietary filler pieces are fitted on both sides of the web between the top and bottom flanges. These filler pieces must not damage the joist flanges. The depth of the filler pieces should be slightly less than the dimension between the joist flanges to achieve a loose fit the mortar joints around each joist perimeter are recessed or struck, and the joint between the masonry and the timber and any other air paths are carefully pointed with silicone mastic Bead of sealant applied to joint between filler piece and top and bottom flanges Proprietary filler piece Bead of sealant applied between wall and joist Points to watch The sealant should be applied after the home is roofed so that the joists and masonry are reasonably dry. The workmanship needs to be good: Masonry blocks should be cut accurately (sawn, where possible) and a struck or recessed mortar joint formed to allow a good silicone mastic bead to allow for shrinkage of both timber and masonry. The use of expanding polyurethane foam is not acceptable for sealing around joist ends. Joists and separating walls Builders should be aware that the new guidance contained in Approved Document E - Resistance to the passage of sound (2003 edition)* shows joists supported on hangers to separating walls. This is considered to be the most reliable method of ensuring adequate sound insulation for separating walls. However, if builders have designs which show joists built into separating walls then the ends do require sealing, to limit air leakage. *see page 5 for more on Part E Whether you use joist hangers or build joists in, follow the above guidance carefully. Consider the implications of building joists into separating walls for buildings that need to comply with the new requirements of Part E. REMINDER - Notification of energy ratings In England and Wales the Building Regulations require that the energy rating of a new home be made known to the home owner as soon as possible. Builders may give the rating directly to the purchaser or choose the most appropriate time for posting the rating notice in the completed home. The intention of the legislation is to ensure that purchasers are aware of the energy efficiency of their new home.research by National Energy Services reveals that this notification is not being carried out. Their findings show that 98% of unsold homes checked did not display the SAP rating. Whilst the research failed to identify whether builders were making the rating known directly to purchasers, a mystery shopping exercise demonstrated that few sales staff understood or even had knowledge of the SAP rating. There is a legal obligation to give details of the SAP rating to home owners and you should consider your approach to complying with the requirement. It is often not practicable to display the energy rating notice prior to occupation of dwellings; in these cases you should ensure that home owners are given this information, perhaps as part of an information pack or via a separate communication. Sales staff are ideally positioned to help inform purchasers regarding energy efficiency and the relevance of the energy ratings for new homes. NHBC Training Services will be happy to advise further on Building Regulation training courses available for sales and other non-technical staff (contact Dave Towell on or DaveT@nhbc.co.uk). Place an easy to read notice of the energy rating in unsold properties - members of the House Builders Federation can obtain a blank notice from the HBF website at When selling off-plan, provide information on the SAP rating to purchasers and ensure sales staff are briefed about the benefits of energy efficient homes. STANDARDS EXTRA 7

8 Questions & Answers Below are the answers to a selection of questions we have recently been asked in NHBC Technical. Handrails to staircases - tapered treads/winders Question Where stairs have tapered treads/winders, is a handrail required to the outside of the stairs? Answer A safe handhold is required for the full rise of any stairs with a total rise greater than 600 mm. A suitable newel post can provide a safe handhold. Single newel In England, Wales and Scotland where the stairs have between one and four tapered treads/winders and the newel provides a safe handhold, a handrail is not required to the outside of the stairs. Double newels In England, Wales and Scotland where the newels provide a safe handhold, a handrail is not required to the outside of the stairs. Additional handrail not needed Additional handrail needed Additional handrail not needed In Northern Ireland a handrail should be fitted to the outside of the stairs in both cases (required by building regulations). In all cases where a handrail is needed to the outside of the stairs, it should be continuous for the whole rise to avoid the need to change hands. Use of nail guns for fixing trussed rafter bracing Question The guage of the nails used in nail guns is less than that quoted in the NHBC Standards. Can these be used for fixing trussed rafter bracing? Answer NHBC Standards clause 7.2 D5(c) asks for 3.35mm (10 guage) x 65mm long galvanised nails nails used in nail guns are not available to this specification. When nail guns are used, 3.1mm x 75mm long annular ring-shank nails are acceptable. They do not need to be galvanised. Roofing underlay at eaves level Question Can plastic dpc material be used at eaves level in place of a type 5U felt? Answer NHBC Standards clause 7.2 M5 (d) says where the underlay is exposed, such as at the eaves, a type 5U felt should be used. Plastic dpc materials are generally not designed for use in permanently exposed locations. The lack of suitable ultra-violet stabilisers could lead to an early breakdown of these materials in such locations. Dpc materials should not be used for the exposed sections of roof underlay at the eaves. A type 5U felt should be used for the exposed sections unless the underlay used for the remainder of the roof has a third party assessment confirming its suitability for use at exposed eaves. Alternatively, a proprietary eaves guard which extends under the unexposed section of the roofing underlay and provides adequate projection into the guttering may be used. 8 NHBC Technical Buildmark House, Chiltern Avenue, Amersham, Bucks HP6 5AP Tel: Fax: technical@nhbc.co.uk HB /03

EXTRA. NHBC s technical newsletter April 2002 Issue 23. This edition includes:

EXTRA. NHBC s technical newsletter April 2002 Issue 23. This edition includes: NHBC s technical newsletter April 2002 Issue 23 This edition includes: 2 3 4 5 6 Major changes to NHBC glazing Standards Glazing requirements amended to improve the durability of insulating glass units.

More information

Good Craftsmanship Guide. Carpentry and Joinery- Carcassing

Good Craftsmanship Guide. Carpentry and Joinery- Carcassing Good Craftsmanship Guide Carpentry and Joinery- Carcassing Introduction This Good Craftsmanship Guide highlights key problems with the major elements of Carpentry and Joinery - Carcassing, and gives guidance

More information

Contents. APA Construction Details. Full fill cavity walls 2-13. Partial fill cavity walls 14-25. Solid externally insulated walls 26-37

Contents. APA Construction Details. Full fill cavity walls 2-13. Partial fill cavity walls 14-25. Solid externally insulated walls 26-37 Contents Pages Full fill cavity walls 2-13 Partial fill cavity walls 14-25 Solid externally insulated walls 26-37 Appendix (BRE confirmation of Ψ and y-values) 38-40 Page 1 of 40 APA Construction Details

More information

House building is changing fast NHBC unveils new Standards Chapters on curtain walling and cladding, and light steel framed walls and floors

House building is changing fast NHBC unveils new Standards Chapters on curtain walling and cladding, and light steel framed walls and floors W42_Stand_Extra_32 15/3/05 9:17 am Page 2 NHBC s technical newsletter April 2005 Issue 32 This edition includes: 2 House building is changing fast NHBC unveils new Standards Chapters on curtain walling

More information

Energy Company Obligation (ECO): Technical Monitoring Questions

Energy Company Obligation (ECO): Technical Monitoring Questions Energy Company Obligation (ECO) Technical Monitoring Questions v1 30/05/2013 Energy Company Obligation (ECO): Technical Monitoring Questions Under ECO suppliers are required to instruct suitably qualified

More information

ONLINE VERSION. The Building Regulations 2010 The Building (Approved Inspectors etc) Regulations 2010 ONLINE VERSION

ONLINE VERSION. The Building Regulations 2010 The Building (Approved Inspectors etc) Regulations 2010 ONLINE VERSION The Building Regulations 2010 The Building (Approved Inspectors etc) Regulations 2010 E1 E2 E3 E4 E Protection against sound from other parts of the building and adjoining buildings Protection against

More information

Solo for Self Build. A guide to the cover

Solo for Self Build. A guide to the cover Solo for Self Build A guide to the cover Choosing the plot, arranging planning permission and finance, designing and building your dream home and finally moving in. Building your own home is, without doubt,

More information

BUILDING CONTROL GUIDANCE SHEET USE OF BREATHABLE ROOFING FELTS.

BUILDING CONTROL GUIDANCE SHEET USE OF BREATHABLE ROOFING FELTS. Building Control Charnwood Borough Council Southfield Road Loughborough LE11 2TN BUILDING CONTROL GUIDANCE SHEET USE OF BREATHABLE ROOFING FELTS. Last updated 16/11/2010 Page 1 of 6 PURPOSE: This Guidance

More information

Fire 2This Technical Bulletin has been commissioned by the UK SIP Association in

Fire 2This Technical Bulletin has been commissioned by the UK SIP Association in REV 1-12.12.11/TB002 Technical Bulletin Fire 2This Technical Bulletin has been commissioned by the UK SIP Association in conjunction with TRADA Technology and is intended to provide the reader with introductory

More information

Patio Covers / Carports

Patio Covers / Carports Patio Covers / Carports Building Guides for Homeowners Why Do I need a Permit? D I D Y O U K N O W? As owner-builder you are the responsible party of record on such a permit. If your work is being performed

More information

Acoustics factsheet Requirements for new homes and how NHBC can help

Acoustics factsheet Requirements for new homes and how NHBC can help Acoustics factsheet Requirements for new homes and how NHBC can help New homes are built to high standards; however, acoustics and noise control are important factors requiring careful consideration during

More information

Document type: Practice Note Title: External and internal membranes Document number: AC2234 Version: 5. 1. Purpose

Document type: Practice Note Title: External and internal membranes Document number: AC2234 Version: 5. 1. Purpose Document type: Practice Note Title: External and internal membranes Document number: AC2234 Version: 5 1. Purpose The purpose of this practice note is to address the incidence of deck and roof membrane

More information

Homeowner s Handbook

Homeowner s Handbook Homeowner s Handbook Congratulations on buying your new home This booklet will provide you with important information on the warranty cover for your new home which has been arranged by your developer.

More information

CERTIFICATE NAME OF PRODUCT MANUFACTURER PRODUCT DESCRIPTION CERTIFICATION PROCEDURE. No VTT C-6044-10 Date of issue 11.10.2010, Updated July 1, 2011

CERTIFICATE NAME OF PRODUCT MANUFACTURER PRODUCT DESCRIPTION CERTIFICATION PROCEDURE. No VTT C-6044-10 Date of issue 11.10.2010, Updated July 1, 2011 CERTIFICATE NAME OF PRODUCT No VTT C-6044-10 Date of issue 11.10.2010, Updated July 1, 2011 H-CONTROL REFLEX+ reflective insulating vapour control layer for roof and wall applications MANUFACTURER ACTIS

More information

Financial Services Authority

Financial Services Authority Financial Services Authity Notice of undertaking Introduction As a qualifying body, we, the Financial Services Authity (the FSA), can challenge firms using terms which we view as unfair under the Unfair

More information

Section 4.3. Separating Floors. Timber frame floor with I-Beams. Upgrading existing timber floor with new ceiling. Timber frame floor with

Section 4.3. Separating Floors. Timber frame floor with I-Beams. Upgrading existing timber floor with new ceiling. Timber frame floor with Section Separating Floors Timber frame floor with I-Beams Product: Earthwool Acoustic Roll and Floorfoam Easy Edge Strip Timber frame floor with solid timber joists Product: Earthwool Acoustic Roll and

More information

Cavity Drain R20 is manufactured from1.0mm thick black high density polyethylene with studs approximately 20mm high.

Cavity Drain R20 is manufactured from1.0mm thick black high density polyethylene with studs approximately 20mm high. CI/SfB Tn6 L6813 September 2013 RIW CAVITY DRAIN R20 R20 is manufactured from1.0mm thick black high density polyethylene with studs approximately 20mm high. Other systems are available for specific uses,

More information

NCMA TEK CONCRETE MASONRY FOUNDATION WALL DETAILS. TEK 5-3A Details (2003)

NCMA TEK CONCRETE MASONRY FOUNDATION WALL DETAILS. TEK 5-3A Details (2003) NCMA TEK National Concrete Masonry Association an information series from the national authority on concrete masonry technology CONCRETE MASONRY FOUNDATION WALL DETAILS TEK 5-3A Details (2003) Keywords:

More information

Services Enclosures and Protected Shafts - Maintaining Compartmentation

Services Enclosures and Protected Shafts - Maintaining Compartmentation Introduction When a fire resisting element is used to provide fire compartmentation, every opening that allows services to pass through the element must be adequately protected by sealing, or fire stopping

More information

Extension. for. Pretend Customer 123 A Road HA7 9BP. at: 123 A Road HA7 9BP

Extension. for. Pretend Customer 123 A Road HA7 9BP. at: 123 A Road HA7 9BP for Pretend Customer at: Pretend Customer Site address: Monday, 23 November 2015 Dear Pretend Customer, Subject: Thank you for your valued enquiry and instructions to quote for the above project. We are

More information

Part 3 Ancillary technologies. Chapter 3.2. Mechanical ventilation with heat recovery

Part 3 Ancillary technologies. Chapter 3.2. Mechanical ventilation with heat recovery Part 3 Ancillary technologies Chapter CONTENTS SCOPE Clause Page DESIGN Design standards D1 1 Statutory requirements D2 1 System design D3 1 Building integration D4 2 Noise D5 2 Access and controls D6

More information

Uncovered Decks & Porches

Uncovered Decks & Porches Uncovered Decks & Porches Building Guides for Homeowners Why Do I need a Permit? D I D Y O U K N O W? As owner-builder you are the responsible party of record on such a permit. If your work is being performed

More information

Contents. Who is Premier Guarantee? Your Structural Warranty. What to look out for in your New Home. Running in your New Home. DIY and Maintenance

Contents. Who is Premier Guarantee? Your Structural Warranty. What to look out for in your New Home. Running in your New Home. DIY and Maintenance Homeowners Handbook Contents Who is Premier Guarantee? Your Structural Warranty What to look out for in your New Home Running in your New Home DIY and Maintenance Structural Warranty Cover This booklet

More information

Module 3.7. Thermal bridging

Module 3.7. Thermal bridging Module 3.7 Thermal bridging Learning Outcomes On successful completion of this module learners will be able to - Describe construction details which influence thermal bridging. 2 Introduction to thermal

More information

THE REDLAND GUIDE TO BS 5534

THE REDLAND GUIDE TO BS 5534 THE REDLAND GUIDE TO BS 5534 HELPING YOUR COMPANY TO GET ONE STEP AHEAD www.redland.co.uk Enforcement is via authorities such as the National House Building Council (NHBC) and Local Authority Building

More information

Standards Committee T echnical Technical Conference

Standards Committee T echnical Technical Conference Standards Committee Technical Conference Agenda Overview of claims costs Years 0 2 claims and resolutions Years 3 10 claims What are we commonly seeing now? An example of what we might see in future? Summary

More information

CHESTERFLEX ROOF WATERPROOFING MEMBRANES

CHESTERFLEX ROOF WATERPROOFING MEMBRANES CI/SfB (47) Ln2 Chesterfelt Ltd CHESTERFLEX ROOF WATERPROOFING MEMBRANES Certificate No 94/3062 DETAIL SHEET 2 Product THIS DETAIL SHEET RELATES TO CHESTERFLEX ROOF WATERPROOFING MEMBRANES, POLYESTER REINFORCED

More information

IRISH BUILDING CONTROL INSTITUTE HOTEL COURT HOTEL BALLYCONNELL CO CAVAN. 26 th MARCH 2009 TIMBER FRAME CONSTRUCTION

IRISH BUILDING CONTROL INSTITUTE HOTEL COURT HOTEL BALLYCONNELL CO CAVAN. 26 th MARCH 2009 TIMBER FRAME CONSTRUCTION IRISH BUILDING CONTROL INSTITUTE HOTEL COURT HOTEL BALLYCONNELL CO CAVAN 26 th MARCH 2009 TIMBER FRAME CONSTRUCTION Bill Robinson BSc. C. Eng. M. I. Struct. E. Timber Design Services 1 IS440 Timber frame

More information

Including. Rubershield-Pro. Breather Membrane

Including. Rubershield-Pro. Breather Membrane Including RubershieldPro Breather Membrane 2 Ruberoid produces a wide range of underslating membranes, primarily to be installed below tiles, slates or metal roofing providing a secondary barrier against

More information

Guidance on loft conversions in two-storey houses

Guidance on loft conversions in two-storey houses Guidance on loft conversions in two-storey houses Technical guidance for building control surveyors, designers and installers 01 Guidance on loft conversions in two-storey houses Technical guidance for

More information

BER Assessors Dwellings Technical Bulletin

BER Assessors Dwellings Technical Bulletin BER Assessors Dwellings Technical Bulletin Issue No. 2/12 April 2012 Contents: 1. SUPPLEMENTARY ELECTRIC WATER HEATING IN SUMMER... 2 2. PITCHED ROOF U-VALUE CALCULATIONS... 8 2.1. PITCHED ROOF, INSULATED

More information

WARMFILL CAVITY WALL INSULATION WARMFILL CAVITY WALL INSULATION FOR MASONRY CAVITY WALLS

WARMFILL CAVITY WALL INSULATION WARMFILL CAVITY WALL INSULATION FOR MASONRY CAVITY WALLS Warmfill Limited Unit 5, Port of Larne Business Park Redlands Road Larne BT40 1AX Tel: 028 9042 8260 Fax: 028 9042 7641 e-mail: sales@warmfill.com website: www.warmfill.com APPROVAL INSPECTION TESTING

More information

Chapter 3 Pre-Installation, Foundations and Piers

Chapter 3 Pre-Installation, Foundations and Piers Chapter 3 Pre-Installation, Foundations and Piers 3-1 Pre-Installation Establishes the minimum requirements for the siting, design, materials, access, and installation of manufactured dwellings, accessory

More information

SOUND INSULATION FOR EXTERIOR WALLS AND FACADE SYSTEMS

SOUND INSULATION FOR EXTERIOR WALLS AND FACADE SYSTEMS NOISE TECHNICAL FACT SHEET FACT SHEET 5 SOUND INSULATION FOR EXTERIOR WALLS AND FACADE SYSTEMS The sound insulation of exterior walls and roof-ceiling systems refers to their ability to reduce external

More information

Mark Cramer Inspection Services, Inc.

Mark Cramer Inspection Services, Inc. Mark Cramer Inspection Services, Inc. 492 Twentieth Avenue, Indian Rocks Beach, FL 34635-2970 (727) 595-4211 Fax (727) 596-7583 Certified Member #12085 American Society of Home Inspectors Construction

More information

Timber Frame Construction

Timber Frame Construction Timber Frame Construction Introduction Design and Detailing What is timber? Failure modes History of timber frame construction Forms of timber frame construction Live and dead loads Wind loads Roof construction

More information

Guide to the safe installation of downlighters in dwellings

Guide to the safe installation of downlighters in dwellings Guide to the safe installation of downlighters in dwellings Technical guidance for designers and installers 01 Guide to the safe installation of downlighters in dwellings Technical guidance for designers

More information

Introduction & Principles Issued in support of Junction Details, Parts 1 to 5

Introduction & Principles Issued in support of Junction Details, Parts 1 to 5 Accredited Construction Details (Scotland) 2010 For the limitation of thermal bridging and air infiltration in low and medium rise domestic buildings Introduction & Principles Issued in support of Junction

More information

Manual lifting and handling

Manual lifting and handling Manual lifting and handling When installing British Gypsum products and systems care should be taken to ensure that appropriate methods of handling and lifting are adopted. The following guidance details

More information

TECHNICAL MANUAL. New Homes

TECHNICAL MANUAL. New Homes TECHNICAL MANUAL New Homes V2 Contents Part 1...5 Introduction and statutory requirements...5 General introduction, layout and use of the manual....5 Functional Requirements...6 Compliance with Building

More information

Rockwool Flexi Insulation Application Guide

Rockwool Flexi Insulation Application Guide Pitched roof Rafters InterMediate floors INTERNAL partitions external Framed walls separating floors Separating Walls Rockwool Flexi Insulation Application Guide Ground floor The perfect fit for any framed

More information

Agrément Certificate 06/4300 Product Sheet 1

Agrément Certificate 06/4300 Product Sheet 1 Domestic and General Insulation Ltd Energy House Magnis Works Roman Road Hereford HR4 9QR Tel: 0844 543 0043 Fax: 01432 268680 e-mail: headoffice@dgi.org.uk website: www.dgi.org.uk APPROVAL INSPECTION

More information

BUILDING CONTROL GUIDANCE SHEET REPLACEMENT WINDOWS AND DOORS Last updated 16/11/2010

BUILDING CONTROL GUIDANCE SHEET REPLACEMENT WINDOWS AND DOORS Last updated 16/11/2010 Building Control Charnwood Borough Council Southfield Road Loughborough LE11 2TN BUILDING CONTROL GUIDANCE SHEET REPLACEMENT WINDOWS AND DOORS Last updated 16/11/2010 Page 1 of 6 PURPOSE: This Guidance

More information

Sample Drawing Package for One and Two Family Dwelling Applications

Sample Drawing Package for One and Two Family Dwelling Applications Sample Drawing Package for One and Two Family Dwelling Applications For a full list of submission requirements, refer to the relevant checklist for your application found on our website: http://vancouver.ca/home-property-development/application-forms-and-checklists.aspx

More information

Understanding BS EN 771-3: Aggregate concrete masonry units

Understanding BS EN 771-3: Aggregate concrete masonry units 60 Charles Street, Leicester LE1 1FB Tel: 0116 253 6161 Fax: 0116 251 4568 Email: enquiries@cba-blocks.org.uk Website: www.cba-blocks.org.uk February 2006 Understanding BS EN 771-3: Aggregate concrete

More information

Ubiflex. Non-lead flashing system

Ubiflex. Non-lead flashing system Ubiflex Non-lead flashing system Ubiflex non-lead flashing Ubiflex is a non-lead waterproof flashing material which can be used in most applications where lead is traditionally used to provide a weatherproof

More information

Electrical for Detached Garages: Updated Feb 19, 2016 for 2015 CE Code in force Jan. 1, 2016. Underground branch circuit feeding a detached garage:

Electrical for Detached Garages: Updated Feb 19, 2016 for 2015 CE Code in force Jan. 1, 2016. Underground branch circuit feeding a detached garage: Electrical for Detached Garages: Updated Feb 19, 2016 for 2015 CE Code in force Jan. 1, 2016 * Garage construction requires permits (electrical, building) * Permits must be applied for at the time. * Dial

More information

FCA CARPENTRY & JOINERY THEORY. 10 SIMPLE ROOF CONSTRUCTION Part 2

FCA CARPENTRY & JOINERY THEORY. 10 SIMPLE ROOF CONSTRUCTION Part 2 CARPENTRY & JOINERY FCA CARPENTRY & JOINERY THEORY 10 SIMPLE ROOF Double Roofs A double roof is a roof whose rafters are of such a length that they require an intermediate support. This support is usually

More information

Timber Frame Walls Rethinking Construction

Timber Frame Walls Rethinking Construction Insulation Fifth Issue November 2007 Timber Frame Walls Rethinking Construction INSULATION BEST PRACTICE FOR THE 21ST CENTURY Summary 9 mm OSB sheathing 3 mm skim coated 15 mm plasterboard Rock or glass

More information

GUIDANCE SHEET FOR CONSERVATORIES, SUNROOMS AND EXTENSIONS TO DWELLINGS.

GUIDANCE SHEET FOR CONSERVATORIES, SUNROOMS AND EXTENSIONS TO DWELLINGS. GUIDANCE SHEET FOR CONSERVATORIES, SUNROOMS AND EXTENSIONS TO DWELLINGS. This leaflet provides guidance on how to attain compliance with The Building (Amendment) Regulations (Northern Ireland) 2006, Part

More information

Cold Weather Concrete Practices

Cold Weather Concrete Practices Cold Weather Concrete Practices The Information below is an outline of common practice for residential foundation placement and winter construction utilize Edmonton and surrounding Area. Conditions in

More information

CERTIFICATE OF APPROVAL No CF 5055 ARABIAN VERMICULITE INDUSTRIES

CERTIFICATE OF APPROVAL No CF 5055 ARABIAN VERMICULITE INDUSTRIES CERTIFICATE OF APPROVAL No CF 5055 This is to certify that, in accordance with TS00 General Requirements for Certification of Fire Protection Products The undermentioned products of 1 st Industrial Area,

More information

Approved Document Q: Security

Approved Document Q: Security Approved Document Q: Security Requirement Q1 Unauthorised access Consultation draft September 2014 1 The approved documents What is an approved document? The Secretary of State has approved a series of

More information

domestic structure SBSG 2007 ANNEX C

domestic structure SBSG 2007 ANNEX C domestic structure SBSG 2007 ANNEX C Small buildings structural guidance 1.A General 1.B Stability 1.C Foundations 1.D Masonry walls 1.E Timber frame walls 1.F Timber floor and roof members contents domestic

More information

Chapter 5.4. Waterproofing of basements and other below ground structures

Chapter 5.4. Waterproofing of basements and other below ground structures Chapter Waterproofing of basements and other below ground structures Waterproofing of basements and other below ground structures CONTENTS SCOPE DESIGN Clause Page D1 Design standards D1 2 D2 Statutory

More information

How To Account For Ict Expenditure In A School

How To Account For Ict Expenditure In A School Extract from HMRC Guidance for Local Authorities (LA) and Voluntary Aided (VA) Schools in England Please note this is an extract from the HMRC Guidance. The full Guidance can be found on the VAT pages

More information

Multi-layer Insulation Blanket for Roofs

Multi-layer Insulation Blanket for Roofs Multilayer Insulation Blanket for Roofs Thermal Insulation in a 40mm thin, flexible, multilayer membrane Meets requirements of L1A, L1B 2010 In accordance with BR443 NHBC Acceptance Pitched & Flat roof

More information

Bituminous Sheet Flat Roofs: Their repair and maintenance

Bituminous Sheet Flat Roofs: Their repair and maintenance Bituminous Sheet Flat Roofs: Their repair and maintenance Flat roof covered in sheets of bituminous felt Introduction Whilst flat roofs are often regarded as inferior to their pitched counterparts and

More information

Uniclass L31:N14:P7111 C1/SfB (16.9) Rn7 (J4) February 2008. Foundation Heave Protection

Uniclass L31:N14:P7111 C1/SfB (16.9) Rn7 (J4) February 2008. Foundation Heave Protection Uniclass L31:N14:P7111 C1/SfB (16.9) Rn7 (J4) February 2008 Foundation Heave Protection The safe, sure way to provide foundation protection Clayshield is the proven solution to protecting foundations against

More information

PRODUCT GUIDE lower tolerances high quality

PRODUCT GUIDE lower tolerances high quality Building the future with Ytong autoclaved aerated concrete PRODUCT GUIDE lower tolerances high quality Introduction Distinctive building with aerated concrete Ytong blocks are a well known global name

More information

Rochdale Building Control Guide. Approved Document C. Site preparation and resistance to contaminants and moisture

Rochdale Building Control Guide. Approved Document C. Site preparation and resistance to contaminants and moisture Rochdale Building Control Guide Approved Document C Site preparation and resistance to contaminants and moisture Dampness is often misdiagnosed within buildings, the approved document deals with prevention

More information

The WANZ Guide to Window Installation

The WANZ Guide to Window Installation The WANZ Guide to Window Installation as described in E2/AS1 Amendment 5 Ver. 1.1 Page 2 of 74 Contents Overview Page 5 Objective Page 5 Scope Page 5 Opening Preparation Page 7 Step P1 Preliminary Check

More information

What is QuickBase? Traditional foundations (left) compared with QuickBase (right)

What is QuickBase? Traditional foundations (left) compared with QuickBase (right) QuickBase is an innovative new foundation and floor system for conservatories and lightweight structures which was launched in prototype form at last year s Interbuild exhibition, where it was hailed as

More information

Timber Decks. Technical Note. March 2007

Timber Decks. Technical Note. March 2007 Timber Decks Technical Note. March 2007 This Technical Note contains general information for residential timber decks and floor frame structures for veranda s, patios etc which are exposed to the weather.

More information

Residential Deck Safety, Construction, and Repair

Residential Deck Safety, Construction, and Repair Juneau Permit Center, 4 th Floor Marine View Center, (907)586-0770 This handout is designed to help you build your deck to comply with the 2006 International Residential Building code as modified by the

More information

Risk Guidance Note 03. Management of In-Rack Automatic Sprinklers (IRAS)

Risk Guidance Note 03. Management of In-Rack Automatic Sprinklers (IRAS) Risk Guidance Note 03 Management of In-Rack Automatic Sprinklers (IRAS) Overview In-rack automatic sprinklers (IRAS) are often a fundamental part of the fire protection solution for racked storage areas.

More information

Building over or close to a public sewer

Building over or close to a public sewer Building over or close to a public sewer thameswater.co.uk/developerservices thameswater.co.uk/developerservices 1 Questions and answers Did you know Thames Water is legally responsible for more than 100,000

More information

WATERPROOFING FOR CONCRETE STRUCTURES

WATERPROOFING FOR CONCRETE STRUCTURES MANUAL OF CONTRACT DOCUMENTS FOR ROAD WORKS VOLUME 1 SPECIFICATION FOR ROAD WORKS SERIES 2000 WATERPROOFING FOR CONCRETE STRUCTURES Contents Clause Title Page 2001 General 2 2002 Protection of Bridge Deck

More information

Asphalt Shingle Application Requirements

Asphalt Shingle Application Requirements Alberta Allied Roofing Association Asphalt Shingle Application Requirements Section 1 Roof Decks 1.1 General Asphalt Shingles are not permitted to be installed directly over rigid insulation. When Asphalt

More information

PRODUCT SHEET 1 MIDLAND LEAD MANUFACTURERS LTD S CAST LEAD SHEET

PRODUCT SHEET 1 MIDLAND LEAD MANUFACTURERS LTD S CAST LEAD SHEET CI/SfB (49) Mh8 Midland Lead Manufacturers Ltd Kiln Way Woodville Swadlincote Derbyshire DE11 8ED Tel: 01283 224555 Fax: 01283 550284 e-mail: sales@midlandlead.co.uk website: www.midlandlead.co.uk Agrément

More information

Envelope INSULATION BATT (2) Avoid Using Batt Insulation With Metal Framing. Pressure or Friction Fit

Envelope INSULATION BATT (2) Avoid Using Batt Insulation With Metal Framing. Pressure or Friction Fit R-H-DI1 INSULATION BATT NR-E-IB1 Avoid Using Batt Insulation With Metal Framing Batt insulation should not be used with metal framing systems. Although it is common to see fiberglass batt insulation installed

More information

KINGSPAN INSULATION KINGSPAN KOOLTHERM K12 FRAMING BOARD INSULATION

KINGSPAN INSULATION KINGSPAN KOOLTHERM K12 FRAMING BOARD INSULATION Kingspan Insulation Limited Pembridge Leominster Herefordshire HR6 9LA Tel: 01544 388601 Fax: 01544 388888 e-mail: general.enquiries@kil.kingspan.co.uk APPROVAL INSPECTION TESTING CERTIFICATION TECHNICAL

More information

Dubai Municipality Standard DMS 1: Part 5: 2004

Dubai Municipality Standard DMS 1: Part 5: 2004 Specification for precast concrete blocks Part 5: Normal-weight concrete-polystyrene sandwich masonry blocks Issue Date Revision Revision Description Prepared by Approved by Authorized by 19/12/2004 Issue

More information

THE DEVELOPMENT OF DESIGN METHODS FOR REINFORCED AND UNREINFORCED MASONRY BASEMENT WALLS J.J. ROBERTS

THE DEVELOPMENT OF DESIGN METHODS FOR REINFORCED AND UNREINFORCED MASONRY BASEMENT WALLS J.J. ROBERTS THE DEVELOPMENT OF DESIGN METHODS FOR REINFORCED AND UNREINFORCED MASONRY BASEMENT WALLS J.J. ROBERTS Technical Innovation Consultancy Emeritus Professor of Civil Engineering Kingston University, London.

More information

Management Consultancy Training. Asbestos Materials. Residential Guide

Management Consultancy Training. Asbestos Materials. Residential Guide Asbestos Materials Residential Guide This guide highlights some of the more common asbestos containing materials (ACMs) in low occupancy residential buildings, their uses and likely locations. The guide

More information

Code of Practice for fire resisting metal doorsets

Code of Practice for fire resisting metal doorsets COP 1005 Code of Practice for fire resisting metal doorsets Scope The aim of this document is to provide guidance on the best practice for, and a better understanding of, hinged or pivoted fire resisting

More information

Fire. The Fire Installers Mate. A guide to fire alarm systems design

Fire. The Fire Installers Mate. A guide to fire alarm systems design Fire The Fire Installers Mate A guide to fire alarm systems design BS 5839 Part 1:2002 A guide to BS 5839 Part 1:2002 Disclaimer This booklet is not intended to be a comprehensive guide to all aspects

More information

Section 5.0. Basements. Wall insulated externally. Wall insulated internally. Ba02. Product: Polyfoam ECO Floorboard Ba01.

Section 5.0. Basements. Wall insulated externally. Wall insulated internally. Ba02. Product: Polyfoam ECO Floorboard Ba01. Section 5.0 Basements Wall insulated externally Product: Polyfoam ECO Ba01 Wall insulated internally Product: Polyfoam ECO Ba02 Basements Basements Basement design Waterproofing BS 8102: 2009 Code of practice

More information

The BASA Guide to the ISO 11600 Classification of Sealants for Building Construction

The BASA Guide to the ISO 11600 Classification of Sealants for Building Construction The BASA Guide to the ISO 11600 Classification of Sealants for Building Construction SEALANTS IN BUILDING AND CONSTRUCTION Glazing Sealants (G) Construction Sealants (F) Class 25 Class 25LM Class 25 Class

More information

Scope of works. Name Job# TBA -1. Project: Bathroom Renovation

Scope of works. Name Job# TBA -1. Project: Bathroom Renovation Scope of works Name Job# TBA -1 Address Date Suburb P. code Phone H BH 0 Mobile E-mail Project: Bathroom Renovation.01 Demolition Strip out and remove from site: All existing fixtures, fittings and cabinets

More information

Tried, Tested and Proven Timber Protection

Tried, Tested and Proven Timber Protection November 05 A Choice of Treatments SPECIFIER S GUIDE Tried, Tested and Proven Timber Protection Preservative and fire retardant industrial treatments to help make the most of timber. Tried, Tested and

More information

Section 3.1.2. Timber Frame Walls. Single layer between studs. Single layer between studs with service void. Between studs with insulated lining

Section 3.1.2. Timber Frame Walls. Single layer between studs. Single layer between studs with service void. Between studs with insulated lining Section Timber Frame Walls Single layer between studs Product: Earthwool FrameTherm Rolls and Slabs Tf01 Single layer between studs with service void Product: Earthwool FrameTherm Rolls and Slabs Tf02

More information

Partitioning & Ceiling Product Information

Partitioning & Ceiling Product Information Partitioning & Ceiling Product Information tel + 44 (0) 1384 412448 fax + 44 (0) 1384 4494 email enquiries@drywallsteelsections.co.uk web www.drywallsteelsections.co.uk tel + 44 (0) 1384 412448 fax + 44

More information

This handout is a guide only and does not contain all of the requirements of the Minnesota State Building Code or city ordinances.

This handout is a guide only and does not contain all of the requirements of the Minnesota State Building Code or city ordinances. Basement Finishing Guide Community Development Department Building Inspections Division 5200 85 th Avenue North / Brooklyn Park, MN 55443 Phone: (763) 488-6379 / Fax: (763) 493-8171 6/15 www.brooklynpark.org

More information

Release: 1. CPCCWP3004A Apply waterproofing remedial processes

Release: 1. CPCCWP3004A Apply waterproofing remedial processes Release: 1 CPCCWP3004A Apply waterproofing remedial processes CPCCWP3004A Apply waterproofing remedial processes Modification History Not Applicable Unit Descriptor Unit descriptor This unit of competency

More information

Improving the flood resistance of your home. Advice sheet 4: Flood-resilient walls.

Improving the flood resistance of your home. Advice sheet 4: Flood-resilient walls. Improving the flood resistance of your home Advice sheet 4: Flood-resilient walls. This sheet provides guidance on identifying different types of wall, and reducing the flow of floodwater through them

More information

Building Control Guidance Note

Building Control Guidance Note Issued 01/01/13 Rev Page 1 of 5 If you intend to convert an existing loft space into additional rooms you will need to apply for Building Regulation Approval. You may also need Planning Permission if you

More information

GreenGuard Housewrap Installation Guide

GreenGuard Housewrap Installation Guide 000768PACBPHW_Flashing Bro 5/23/03 2:52 PM Page 1 For the most current product information, go to www.green-guard.com. Pactiv Building Products believes the information and recommendations herein to be

More information

How To Certify The Scottsdale Construction System

How To Certify The Scottsdale Construction System BRE CERTIFICATION LIMITED PRODUCT SCOTTSDALE CONSTRUCTION SYSTEM CERTIFICATE NUMBER 129/07 DATE OF ISSUE December 2007 SUPPLIED BY Scottsdale Construction System Ltd SUMMARY The Scottsdale Construction

More information

Tested to BS 6375: Part 1: 1989 and achieved a weathertightness classification of 2000 Pa (Special)

Tested to BS 6375: Part 1: 1989 and achieved a weathertightness classification of 2000 Pa (Special) THE B6 GLAZING SYSTEM GLAZING SYSTEMS FOR SEPTEMBER 2013 THE B6 HEEL BEAD SEAL SECURITY GLAZING SYSTEM Page 1 DESCRIPTION The B6 Heel Bead Seal Security Glazing System is suitable for installing all types

More information

PRODUCT GUIDE. Building the future with Ytong autoclaved aerated concrete. low tolerances high quality

PRODUCT GUIDE. Building the future with Ytong autoclaved aerated concrete. low tolerances high quality Building the future with Ytong autoclaved aerated concrete PRODUCT GUIDE low tolerances high quality XEL0002_Productguide_versie januari 2016.indd 1 11-01-16 13:03 This is Xella Xella is a leading manufacturer

More information

NRG 75 CRF NRG GREENBOARD WALL SYSTEM

NRG 75 CRF NRG GREENBOARD WALL SYSTEM NRG GREENBOARD WALL SYSTEM NRG Energy Efficient Building Systems is pleased to announce a revolution in lightweight cladding systems. NRG Building Systems is the first and only company to achieve CodeMark

More information

SECTION 7: C - STRUCTURAL ENGINEERS SPECIFICATIONS

SECTION 7: C - STRUCTURAL ENGINEERS SPECIFICATIONS SECTION 7: C - STRUCTURAL ENGINEERS SPECIFICATIONS SITE C SHOPPING CENTRE, KHAYELITSHA PROJECT NO 2369 Project Specification Refer all queries to: John Meiring Tel: +27 21 425 0065 REVISION P01 E-mail:

More information

POST AND FRAME STRUCTURES (Pole Barns)

POST AND FRAME STRUCTURES (Pole Barns) POST AND FRAME STRUCTURES (Pole Barns) Post and frame structures. The following requirements serve as minimum standards for post and frame structures within all of the following structural limitations:

More information

2014 British Columbia Building Code Changes

2014 British Columbia Building Code Changes District of Houston 250-845-2238 2014 British Columbia Building Code Changes A District of Houston interpretation of the 2014 Building Code Changes for 9.36 & 9.32 The following changes reflect the most

More information

Monocouche Best Practice Guide. New-Build Housing Managing movement to avoid cracking

Monocouche Best Practice Guide. New-Build Housing Managing movement to avoid cracking Monocouche Best Practice Guide New-Build Housing Managing movement to avoid cracking Avoiding Cracking For The Designer Visible cracks in render are unsightly and although not hazardous to the construction

More information

Why buy this home? Protected by NHBC Buildmark

Why buy this home? Protected by NHBC Buildmark Why buy this home? Protected by NHBC Buildmark Your Buildmark cover 10 years protection NHBC Buildmark cover is a 10 year policy included by your builder in the purchase price of your property, providing

More information

Asbestos in your home

Asbestos in your home Asbestos in your home Is it a problem? BVT RESIDENT A P P R O V E D This leaflet aims to address any concerns that you may have regarding asbestos and where it may be found in your home. It will cover

More information

Building Regulations for the Conservation of Fuel and Power

Building Regulations for the Conservation of Fuel and Power Insulation CI/SfB Rn7 M2 First Issue April 2014 Building Regulations for the Conservation of Fuel and Power ENGLAND EXISTING DWELLINGS 2013 EDITION Low Energy Low Carbon Buildings Contents Page Introduction

More information

HOUSING STANDARDS POLICY TRANSITION STATEMENT IMPLEMENTATION: OCTOBER 2015. May 2015

HOUSING STANDARDS POLICY TRANSITION STATEMENT IMPLEMENTATION: OCTOBER 2015. May 2015 HOUSING STANDARDS POLICY TRANSITION STATEMENT IMPLEMENTATION: OCTOBER 2015 May 2015 MAYOR OF LONDON Housing Standards: Transition Policy Statement. On 25 March 2015 through a written ministerial statement,

More information