1 WIRE AND CABLE SOLUTIONS CSA PRODUCT CATALOGUE
2 WIRE AND CABLE SOLUTIONS Contents About ShawFlex Capabilities Overview... 4 Product Selection Guide Instrumentation Instrumentation, Pairs & Triads (Armoured - 300V)... 6 Instrumentation, Pairs & Triads (Armoured - 600V)... 8 Instrumentation, Pairs & Triads (Tray - 300V) Tray Power/Control Control, Multi-Conductor (600V) Power, Multi-Conductor (1000V) Power, Single Conductor (1000V) Teck90 Power/Control Control, Multi-Conductor (600V) Control, Multi-Conductor (1000V) Power, Single Conductor (1000V) Power, Multi-Conductor(1000V) Power, Single Conductor (Unshielded V) Power, Single Conductor (Shielded V) Power, Multi-Conductor (Unshielded V) Power, Multi-Conductor (Shielded V) Thermocouple Thermocouple Extension, Pairs (AIA - 300V) Thermocouple Extension, Pairs (Tray - 300V) Low Smoke Zero Halogen (LSZH) Instrumentation, Pairs & Triads (Tray - 300V) Control, Multi-Conductor (Tray - 300V) Control, Multi-Conductor (Tray - 600V) Control, Multi-Conductor (AIA - 600V) Control, Multi-Conductor (AIA V) Power, Multi-Conductor (Tray V) Power, Multi-Conductor (AIA V) Building/Utility/Industrial Cables RW90, Single Conductor (600V) RW90, Single Conductor (1000V) RWU90, Single Conductor (1000V) Mineshaft/Riser Cables (1000/5000V) ARMCON, Multi-Conductor (Armoured - 600V) Safe-T Ground, Single Conductor (1000V) Fieldbus, Pairs (300/600V) Utility, Multi-Conductor (1000V) VFD, Multi-Conductor (1000V)
3 RODUCT CATALOG 3
4 INNOVATIVE WIRE AND CABLE SOLUTIONS From common to custom ShawFlex is committed to leading the industry with innovative solutions that are proven, dependable and tested to the highest standards and precisely manufactured to your specifications. Many customers rely on our unique in-house design capability and expertise to tackle projects of all scopes and sizes. We provide comprehensive services, advanced in-house materials and product research as well as product development and pre-qualification testing. We offer customers much more than a catalogue of products. We provide the technical leadership and service responsiveness needed to meet all of your project deadlines as well as your performance requirements to produce a dependable and superior product.
5 V.2 5 The design process ShawFlex is uniquely positioned as both a run to order and an engineered to order wire and cable company. Run to order products are available from our extensive catalogue of standard constructions/items. For engineered to order cables, our highly skilled technical team will work with you to interpret performance criteria, determine innovative solutions and optimize cable capabilities while ensuring the cable meets all applicable safety and specification requirements. ShawFlex is ready to help you meet the high performance needs of today. KEY MARKETS Oil & Gas Oil and gas investment Refinery expansion Industrial Construction developments Maintenance, repair and operations Forestry Wastewater treatment Mining Utilities Power generation Nuclear refurbishment and new builds Transmission upgrades
6 CSA INSTRUMENTATION V.2 6 ARMOURED INSTRUMENTATION PAIRS & TRIADS (300V) PAGE 1 OF 2 HL Armoured Instrumentation cables can be used to minimize noise and singal interference by preventing crosstalk between pairs and triads. This cable can also be used to convert analogue or digital signals. Tray Instrumentation cables can be installed in raceways, direct burial applications and in outdoor exposed industrial applications, 300V Optional: 600/1000V - FR XLPE/XLPE (RW90 rated) (standard) rated: 90 C wet/ 105 C dry - PVC (optional) Shielding (foil-free edge): - ISOS (standard) - OS (optional) Armour: - Aluminum Interlocked Armour (AIA) (standard) - Steel Interlocked Armour (SIA) (optional) - Serve Wire Armour (SIA) (optional) - FR LAG PVC (AG14 rated) inner black jacket - FR LAG PVC (AG14 rated) outer grey jacket - Copper taper or braided shield - Custom colour coding - Composite constructions PAIRS Pairs CSA C22.2 NO. 239, Control & Instrumentation Cables (Type ACIC) CSA C22.2 NO. 174, Cables & Cable Glands for use in Hazardous Locations CSA C22.2 NO. 38, Thermoset Insulated Wires & Cables (XLPE) CSA FT4, UL 1685 FT4, Vertical Tray Flame Flame XLPE (RW90 rated), 90 C wet/105 C dry -40 C cold bend/impact rated HL rated for use in hazardous locations: - Class 1 Zone 0 (Intrinsically Safe cables only) - Class I Zone 1 (Div 1) - HL-BCD gas groups rated Pairs - Black, & white, with black printing on white (standard) Triads - Black, white & red, with black printing on white (standard) OD Over Inner Jacket Normal Diameters Stranded Bare Copper (Tinned Available) 2. XLPE (RW90 Rated) Insulated 3. Individual Shield & Overall Shielded Pairs/Triads 4. Polypropylene Fillers 5. Polyester Separator Tape 6. Overall Aluminum/Mylar Shield with Tinned Copper Drain Wire 7. FR LAG PVC Inner Protective Jacket 8. Aluminum Interlocked Armour (AIA) 9. FR LAG PVC Outer Protective Jacket (lbs/1000ft)/ Min. Bend Radius (Pull) 64221M / / / / / / M / / / / / / M / / / / / / M / / / / / / M / / / / / / M / / / / / / M / / / / / / M / / / / / / M / / / / / / M / / / / / / M / / / / / / M / / / / / / M / / / / / / M / / / / / / M / / / / / / M / / / / / / M / / / / / / 682
7 CSA INSTRUMENTATION V.2 7 ARMOURED INSTRUMENTATION PAIRS & TRIADS (300V) PAGE 2 OF 2 HL PAIRS (CONTINUED) Pairs OD Over Inner Jacket Normal Diameters (lbs/1000ft)/ Min. Bend Radius (Pull) 64231M / / / / / / M / / / / / / M / / / / / / M / / / / / / M / / / / / / M / / / / / / M / / / / / / M / / / / / / M / / / / / / 651 TRIADS Triads OD Over Inner Jacket Normal Diameters (lbs/1000ft)/ Min. Bend Radius (Pull) 64231M / / / / / / M / / / / / / M / / / / / / M / / / / / / M / / / / / / M / / / / / / M / / / / / / M / / / / / / M / / / / / / M / / / / / / M / / / / / / M / / / / / / M / / / / / / M / / / / / / M / / / / / / M / / / / / / M / / / / / / M / / / / / / M / / / / / / M / / / / / / M / / / / / / M / / / / / / M / / / / / / M / / / / / / 648
8 CSA INSTRUMENTATION V.2 8 ARMOURED INSTRUMENTATION PAIRS & TRIADS (600V) PAGE 1 OF 2 HL Armoured Instrumentation cables are used to convert analogue or digital signals. Used when there is a possibility for crosstalk between pairs/triads. Interlocked armour replaces the use of conduit for mechanical protection. Cables can be installed in raceways, direct burial applications and in outdoor exposed Industrial applications. 600V Optional: 300/1000V - FR XLPE/XLPE (RW90 rated) (standard) rated: 90 C wet/ 105 C dry - PVC (optional) Shielding (foil-free edge): - ISOS (standard) - OS (optional) Armour: - Aluminum Interlocked Armour (AIA) (standard) - Steel Interlocked Armour (SIA) (optional) - Serve Wire Armour (SIA) (optional) - FR LAG PVC (AG14 rated) inner black jacket - FR LAG PVC (AG14 rated) outer grey jacket - Copper taper or braided shield PAIRS Pairs CSA C22.2 NO. 239, Control & Instrumentation Cables (Type ACIC) CSA C22.2 NO. 174, Cables & Cable Glands for use in Hazardous Locations CSA C22.2 NO. 38, Thermoset Insulated Wires & Cables (XLPE) CSA FT4, UL 1685 FT4, Vertical Tray Flame Flame XLPE (RW90 rated), 90 C wet/105 C dry -40 C cold bend/impact rated HL rated for use in hazardous locations: - Class 1 Zone 0 (Intrinsically Safe cables only) - Class I Zone 1 (Div 1) - HL-BCD gas groups rated Pairs - Black, & white Triads - Black, white & red OD Over Inner Jacket Normal Diameters (lbs/1000ft)/ Stranded Bare Copper (Tinned Available) 2. XLPE (RW90 Rated) Insulated 3. Individual Shield & Overall Shielded Pairs/Triads 4. Polypropylene Fillers 5. Polyester Separator Tape 6. Overall Aluminum/Mylar Shield with Tinned Copper Drain Wire 7. FR LAG PVC Inner Protective Jacket 8. Aluminum Interlocked Armour (AIA) 9. FR LAG PVC Outer Protective Jacket 8 9 Min. Bend Radius (Pull) 69221M / / / / / / M / / / / / / M / / / / / / M / / / / / / M / / / / / / M / / / / / / M / / / / / / M / / / / / / M / / / / / / M / / / / / / M / / / / / / M / / / / / / M / / / / / / M / / / / / / M / / / / / / M / / / / / / M / / / / / / M / / / / / / 847
9 CSA INSTRUMENTATION V.2 9 ARMOURED INSTRUMENTATION PAIRS & TRIADS (600V) PAGE 2 OF 2 HL TRIADS Triads OD Over Inner Jacket Normal Diameters (lbs/1000ft)/(kg/ km) Min. Bend Radius (Pull) 69231M / / / / / / M / / / / / / M / / / / / / M / / / / / / M / / / / / / M / / / / / / M / / / / / / M / / / / / / M / / / / / / M / / / / / / M / / / / / / M / / / / / / M / / / / / / M / / / / / / M / / / / / / M / / / / / / 844
10 CSA INSTRUMENTATION V.2 10 TRAY INSTRUMENTATION PAIRS & TRIADS (300V) PAGE 1 OF 2 TC Tray Instrumentation cables can be used to minimize noise and signal interference by preventing crosstalk between pairs and triads. This cable can also be used to convert analogue or digital signals. Tray Instrumentation cables can be installed in raceways, direct burial applications and in outdoor exposed industrial applications. 300V Optional: 600/1000V rated: 90 C wet/dry Shielding (foil-free edge): - ISOS (standard) - OS (optional) - FR PVC outer black jacket - Composite constructions CSA C22.2 NO. 230, Tray Cables (TC) CSA C22.2 NO. 239, Control & Instrumentation Cables (Type CIC) CSA C22.2 NO. 38, Thermoset Insulated Wires & Cables (XLPE) CSA FT4, UL 1685 FT4, Vertical Tray Flame Flame XLPE (RW90 rated), 90 C wet/ 105 C dry -40 C cold bend/impact rated Rated for use in hazardous locations: - Class I Zone 0 (Intrinsically Safe cables only) - TC-BCD gas groups rated Pairs - Black, & white, with black printing on white (standard) Triads - Black, white & red, with black printing on white (standard) Stranded Bare Copper (Tinned Available) 2. XLPE (RW90 Rated) Insulated 3. Individual Shield & Overall Shielded Pairs/ Triads with Tinned Copper Drain Wire 4. Polyester Separator Tape 5. Overall Aluminum/Mylar Shield with Tinned Copper Drain Wire 6. PVC Outer Protective Jacket 6 PAIRS Pairs Nominal Diameter Overall Cable (lbs/1000ft)/ Min. Bend Radius (Pull) 4B021M / / / / 159 4B022M / / / / 235 4B022M / / / / 289 4B022M / / / / 346 4B022M / / / / 375 4B022M / / / / 476 4B022M / / / / 530 4B022M / / / / 658 4B022M / / / / 758 4B022M / / / / 217 4B022M / / / / 267 4B022M / / / / 318 4B022M / / / / 345 4B022M / / / / 438 4B022M / / / / 487 4B022M / / / / 601 4B022M / / / / 692
11 CSA INSTRUMENTATION V.2 11 TRAY INSTRUMENTATION PAIRS & TRIADS (300V) PAGE 2 OF 2 TC PAIRS (CONTINUED) Pairs Nominal Diameter Overall Cable (lbs/1000ft)/ Min. Bend Radius (Pull) 4B021M / / / / 139 4B022M / / / 15 8 / 202 4B022M / / / / 235 4B022M / / / / 295 4B022M / / / / 320 4B022M / / / / 406 4B022M / / / / 450 4B022M / / / / 554 4B022M / / / / 636 TRIADS Triads Nominal Diameter Overall Cable (lbs/1000ft)/ Min. Bend Radius (Pull) 4B031M / / / / 167 4B032M / / / / 281 4B032M / / / / 328 4B032M / / / / 413 4B032M / / / / 447 4B032M / / / / 543 4B032M / / / / 606 4B032M / / / / 755 4B031M / / / / 155 4B032M / / / / 260 4B032M / / / / 302 4B032M / / / / 362 4B032M / / / / 411 4B032M / / / / 498 4B032M / / / / 555 4B032M / / / / 688 4B031M / / / / 145 4B032M / / / 22 9 / 229 4B032M / / / 22 9 / 229 4B032M / / / / 281 4B032M / / / / 364 4B032M / / / / 461 4B032M / / / / 513 4B032M / / / / 635
12 CSA TRAY V.2 12 CONTROL MULTI-CONDUCTOR (600V) PAGE 1 OF 2 TC Tray Control cables are suitable for use in ventilated, non-ventilated and ladder type cable trays, direct burial, raceways and for exposed or concealed wiring in wet, damp or dry locations in -40 C (40 F) environments. Applicable for use in Utilities, Industrial and Commercial applications. 600V Optional: 1000/2000V rated: 90 C wet/105 C dry Shielding (foil-free edge): - OS (optional) - FR PVC outer black jacket - Composite constructions CSA C22.2 NO. 230, Tray Cables (TC) CSA C22.2 NO. 239, Control & Instrumentation Cables (Type CIC) CSA C22.2 NO. 38, Thermoset Insulated Wires & Cables (XLPE) CSA FT4, UL 1685 FT4, Vertical Tray Flame Flame XLPE (RW90 rated), 90 C wet/ 105 C dry -40 C cold bend/impact rated Rated for use in hazardous locations: - Class I Zone 0 (Intrinsically Safe cables only) 2C Black & white 3C Black, red & white 4C Black, red, blue & white 5C to 50C Black # coded Grounding/Bonding Conductor 2. Strand Bare (ASTM B8) Annealed Copper 3. XLPE (RW90 Rated) Insulated 4. Polypropylene Fillers 5. Polyester Separator Tape 6. FR PVC Outer Protective Jacket Ground Wire Size Nominal Diameter (lbs/1000ft)/ Min. Bend Radius (Pull) 4C010M / / / / 85 4C010M / / / / 92 4C010M / / / / 100 4C010M / / / / 106 4C010M / / / / 115 4C010M / / / / 131 4C010M / / / / 141 4C010M / / / / 153 4C010M / / / / 157 4C010M / / / / 165 4C010M / / / / 169 4C010M / / / / 192 4C010M / / / / 223 4C010M / / / / 235 4C010M / / / / 262 4C010M / / / / 262 4C010M / / / / 291 4R010M / / / / 93 4R010M / / / 71 4 / 101 * value based on Canadian Electrical Code, Version 2012, Table-2. Values are corrected according to Table-5C for number of.
13 CSA TRAY V.2 13 CONTROL MULTI-CONDUCTOR (600V) PAGE 2 OF 2 TC Ground Wire Size Nominal Diameter (lbs/1000ft)/ Min. Bend Radius (Pull) 4R010M / / / / 110 4R010M / / / / 117 4R010M / / / / 135 4R010M / / / / 145 4R010M / / / / 156 4R010M / / / / 169 4R010M / / / / 174 4R010M / / / / 183 4R010M / / / / 188 4R010M / / / / 223 4R010M / / / / 247 4R010M / / / / 261 4R010M / / / / 292 4R010M / / / / 292 4R010M / / / / 325 4R010M / / / / 105 4R010M / / / / 114 4R010M / / / / 131 4R010M / / / / 140 4R010M / / / / 152 4R010M / / / / 164 4R010M / / / / 176 4R010M / / / / 192 4R010M / / / / 207 4R010M / / / / 218 4R010M / / / / 218 4R010M / / / / 223 4R010M / / / / 282 4R010M / / / / 298 4R010M / / / / 334 4R010M / / / / 334 4R010M / / / / 372 * value based on Canadian Electrical Code, Version 2012, Table-2. Values are corrected according to Table-5C for number of.
14 CSA TRAY V.2 14 POWER CONTROL MULTI-CONDUCTOR (1000V) PAGE 1 OF 2 TC Tray Power Control cables are suitable for use in ventilated, non-ventilated and ladder type cable trays, direct burial, raceways and for exposed or concealed wiring in wet, damp or dry locations in -40 C (40 F) environments. Applicable for use in Utilities, Industrial and Commercial applications. 1000V Optional: 600/2000V rated: 90 C wet/105 C dry Shielding (foil-free edge): - OS (optional) - FR PVC outer black jacket - Composite constructions - Aluminum conductors CSA C22.2 NO. 230, Tray Cables (TC) CSA C22.2 NO. 239, Control & Instrumentation Cables (Type CIC) CSA C22.2 NO. 38, Thermoset Insulated Wires & Cables (XLPE) CSA FT4, UL 1685 FT4, Vertical Tray Flame Flame XLPE (RW90 rated), 90 C wet/ 105 C dry -40 C cold bend/impact rated Rated for use in hazardous locations: - Class I Zone 0 (Intrinsically Safe cables only) 2C Black & white 3C Black, red & white 4C Black, red, blue & white 5C to 50C Black # coded Grounding/Bonding Conductor 2. Stranded Bare (ASTM B8) Annealed Copper 3. XLPE (RW90 Rated) Insulated 4. Polypropylene Fillers 5. Polyester Separator Tape 6. FR PVC Outer Protective Jacket Ground Wire Size Nominal Diameter (lbs/1000ft)/ Min. Bend Radius (Pull) 4D010M / / / / 99 4S010M / / / / 107 4S010M / / / / 118 4D010M / / / / 139 4D010M / / / / 170 4D010M / / / / 192 4D010M / / / / 213 4D010M / / / / 227 4D010M / / / / 263 4D010M1/ / / / / / 282 4D010M2/ / / / / / 301 4D010M3/ / / / / / 325 4D010M4/ / / / / / 350 4D010M / / / / 380 4D010M / / / / 418 4D010M / / / / 441 4D010M / / / / 500 4D010M / / / / 582 * value based on Canadian Electrical Code, Version 2012, Table-2. Values are corrected according to Table-5C for number of.
15 CSA TRAY V.2 15 POWER CONTROL MULTI-CONDUCTOR (1000V) PAGE 2 OF 2 TC Ground Wire Size Nominal Diameter (lbs/1000ft)/ Min. Bend Radius (Pull) 4D010M / / / / 107 4S010M / / / / 117 4S010M / / / / 136 4D010M / / / / 151 4D010M / / / / 186 4D010M / / / / 213 4D010M / / / / 226 4D010M / / / / 241 4D010M / / / / 280 4D010M1/ / / / / / 300 4D010M2/ / / / / / 321 4D010M3/ / / / / / 346 4D010M4/ / / / / / 373 4D010M / / / / 420 4D010M / / / / 446 4D010M / / / / 470 4D010M / / / / 533 4D010M / / / / 621 4D010M / / / / 117 4S010M / / / / 134 4S010M / / / / 148 4D010M / / / / 164 4D010M / / / / 212 4D010M / / / / 239 4D010M / / / / 254 4D010M / / / / 272 4D010M / / / / 309 4D010M1/ / / / / / 331 4D010M2/ / / / / / 355 4D010M3/ / / / / / 383 4D010M4/ / / / / / 427 4D010M / / / / 464 4D010M / / / / 493 4D010M / / / / 520 4D010M / / / / 591 4D010M / / / / 703 * value based on Canadian Electrical Code, Version 2012, Table-2. Values are corrected according to Table-5C for number of.
16 CSA TRAY V.2 16 POWER CONTROL SINGLE CONDUCTOR (1000V) PAGE 1 OF 1 TC Tray Power Control cables are suitable for use in ventilated, non-ventilated and ladder type cable trays, direct burial, raceways and for exposed or concealed wiring in wet, damp or dry locations in -40 C (40 F) environments. Applicable for use in Utilities, Industrial and Commercial applications. 1000V Optional: 600V/2000V rated: 90 C wet/dry Shielding (foil-free edge): - OS (optional) - FR PVC outer black jacket - Composite constructions - Aluminum conductors CSA C22.2 NO. 230, Tray Cables (TC) CSA C22.2 NO. 239, Control & Instrumentation Cables (Type CIC) CSA C22.2 NO. 38, Thermoset Insulated Wires & Cables (XLPE) CSA FT4, UL 1685 FT4, Vertical Tray Flame Flame XLPE (RW90 rated), 90 C wet/ 105 C dry -40 C cold bend/impact rated Rated for use in hazardous locations: - Class I Zone 0 (Intrinsically Safe cables only) Black conductor (standard) Strand Bare (ASTM B8) Annealed Copper 2. XLPE (RW90 Rated) Insulated Conductor 3. FR PVC Outer Protective Jacket Nominal Diameter (lbs/1000ft)/ Min. Bend Radius (Pull) 4D010M1/ / / / / / 144 4D010M2/ / / / / / 153 4D010M3/ / / / / / 165 4D010M4/ / / / / / 178 4D010M / / / / 202 4D010M / / / / 214 4D010M / / / / 226 4D010M / / / / 255 4D010M / / / / 296 4D010MA / / / / 330 * value based on Canadian Electrical Code, Version 2012, Table-2. Values are corrected according to Table-5C for number of.
17 CSA TECK 90 V.2 17 CONTROL MULTI-CONDUCTOR (600V) PAGE 1 OF 2 HL Unshielded armoured control cable is used for operation of control automation equipment. Interlocked armour replaces the use of conduit for mechanical protection. Cable can be directly buried, installed in raceways, including cable tray in wet or dry environments. Cable is suitable for use in outdoor exposed applications and is rated for damp or dry locations in -40 C (-40 F) environments. 600 V Optional: 1000V rated: 90 C wet/dry Armour: - Aluminum Interlocked Armour (AIA) (standard) - Steel Interlocked Armour (SIA) (optional) - FR LAG PVC (AG14 rated) inner/outer black jacket - Variable Frequency Drive (VFD) - Verlock (for mineshaft applications) - Custom colour coding - Composite constructions CSA C22.2 NO. 131, Teck 90 Cables (Teck 90) CSA C22.2 NO. 174, Cables & Cable Glands for use in Hazardous Locations CSA C22.2 NO. 38, Thermoset Insulated Wires & Cables (XLPE) CSA FT4, UL 1685 FT4, Vertical Tray Flame Flame XLPE (RW90 rated), 90 C wet/dry -40 C cold bend/impact rated HL rated for use in hazardous locations: - Class I Zone 0 (Intrinsically Safe cables only) - Class I Zone 1 (Div 1) - Class II Zone 20, 21 (Div 1) - Class II Zone 22 (Div 2) 2C Black & white 3C Black, red & white 4C Black, red, blue & white 5C to 50C Black # coded Strand Bare (ASTM B8) Annealed Copper 2. Grounding/Bonding Conductor 3. XLPE (RW90 Rated) Insulated 4. Polyester Separator Tape 5. FR LAG PVC Inner Protective Jacket 6. Aluminum Interlocked Armour (AIA) 7. FR LAG PVC Outer Protective Jacket Ground Wire Size (uninsulated) OD Over Inner Jacket Normal Diameters (lbs/1000ft)/ Max. Pulling Tension (Pulling Eye) (lb/kg) Min. Bend Radius (Pull) 86210M / / / / / / M / / / / / / M / / / / / / M / / / / / / M / / / / / / M / / / / / / M / / / / / / M / / / / / / M / / / / / / M / / / / / / M / / / / / / M / / / / / / M / / / / / / M / / / / / / M / / / / / / M / / / / / / 338 * value based on Canadian Electrical Code, Version 2012, Table-2. Values are corrected according to Table-5C for number of.
18 CSA TECK 90 V.2 18 CONTROL MULTI-CONDUCTOR (600V) PAGE 2 OF 2 HL Ground Wire Size (uninsulated) OD Over Inner Jacket Normal Diameters (lbs/1000ft)/ Max. Pulling Tension (Pulling Eye) (lb/kg) Min. Bend Radius (Pull) 86210M / / / / / / M / / / / / / M / / / / / / M / / / / / / M / / / / / / M / / / / / / M / / / / / / M / / / / / / M / / / / / / M / / / / / / M / / / / / / M / / / / / / M / / / / / / M / / / / / / M / / / / / / M / / / / / / M / / / / / / M / / / / / / M / / / / / / M / / / / / / M / / / / / / M / / / / / / M / / / / / / M / / / / / / M / / / / / / M / / / / / / M / / / / / / M / / / / / / M / / / / / / 932 * value based on Canadian Electrical Code, Version 2012, Table-2. Values are corrected according to Table-5C for number of.
19 CSA TECK 90 V.2 19 CONTROL MULTI-CONDUCTOR (1000V) PAGE 1 OF 2 HL Unshielded armoured control cable is used for operation of control automation equipment. Interlocked armour replaces the use of conduit for mechanical protection. Cable can be directly buried, installed in raceways, including cable tray in wet or dry environments. Cable is suitable for use in outdoor exposed applications and is rated for damp or dry locations in -40 C (-40 F) environments V Optional: 600V rated: 90 C wet/dry Armour: - Aluminum Interlocked Armour (AIA) (standard) - Steel Interlocked Armour (SIA) (optional) - FR LAG PVC (AG14 rated) inner/outer black jacket - Variable Frequency Drive (VFD) - Verlock (for mineshaft applications) - Custom colour coding - Composite constructions CSA C22.2 NO. 131, Teck 90 Cables (Teck 90) CSA C22.2 NO. 174, Cables & Cable Glands for use in Hazardous Locations CSA C22.2 NO. 38, Thermoset Insulated Wires & Cables (XLPE) CSA FT4, UL 1685 FT4, Vertical Tray Flame Flame XLPE (RW90 rated), 90 C wet/dry -40 C cold bend/impact rated HL rated for use in hazardous locations: - Class I Zone 0 (Intrinsically Safe cables only) - Class I Zone 1 (Div 1) - Class II Zone 20, 21 (Div 1) - Class II Zone 22 (Div 2) 2C Black & white 3C Black, red & white 4C Black, red, blue & white 5C to 50C Black # coded Strand Bare (ASTM B8) Annealed Copper 2. Grounding/Bonding Conductor 3. XLPE (RW90 Rated) Insulated 4. Polyester Separator Tape 5. FR LAG PVC Inner Protective Jacket 6. Aluminum Interlocked Armour (AIA) 7. FR LAG PVC Outer Protective Jacket Ground Wire Size (uninsulated) OD Over Inner Jacket Normal Diameters (lbs/1000ft)/ Max. Pulling Tension (Pulling Eye) (lb/kg) Min. Bend Radius (Pull) 80210M / / / / / / M / / / / / / M / / / / / / M / / / / / / M / / / / / / M / / / / / / M / / / / / / M / / / / / / M / / / / / / M / / / / / / M / / / / / / M / / / / / / M / / / / / / M / / / / / / M / / / / / / M / / / / / / 366 * value based on Canadian Electrical Code, Version 2012, Table-2. Values are corrected according to Table-5C for number of.*
20 CSA TECK 90 V.2 20 CONTROL MULTI-CONDUCTOR (1000V) PAGE 2 OF 2 HL Ground Wire Size (uninsulated) OD Over Inner Jacket Normal Diameters (lbs/1000ft)/ Max. Pulling Tension (Pulling Eye) (lb/kg) Min. Bend Radius (Pull) 80210M / / / / / / M / / / / / / M / / / / / / M / / / / / / M / / / / / / M / / / / / / M / / / / / / M / / / / / / M / / / / / / M / / / / / / M / / / / / / M / / / / / / M / / / / / / M / / / / / / M / / / / / / M / / / / / / M / / / / / / M / / / / / / M / / / / / / M / / / / / / M / / / / / / M / / / / / / M / / / / / / M / / / / / / M / / / / / / M / / / / / / M / / / / / / M / / / / / / M / / / / / / 1073 * value based on Canadian Electrical Code, Version 2012, Table-2. Values are corrected according to Table-5C for number of.
21 CSA TECK 90 V.2 21 POWER SINGLE CONDUCTOR (1000V) PAGE 1 OF 1 HL Unshielded armoured power cable is used to supply power for lighting, drives, motors and pumps. Interlocked armour replaces the use of conduit for mechanical protection. Cable can be directly buried, installed in raceways, including cable tray in wet or dry environments. Cable is suitable for use in outdoor exposed applications and is rated for damp or dry locations in -40 C (-40 F) environments V Optional: 600V Grounding/Bonding Conductor: - Concentric serving of solid bare copper wires applied over the insulation rated: 90 C wet/dry Armour: - Aluminum Interlocked Armour (AIA) (standard) - FR LAG PVC (AG14 rated) outer black jacket - Verlock (for mineshaft applications) - Custom colour coding - Aluminum conductors CSA C22.2 NO. 131, Teck 90 Cables (Teck 90) CSA C22.2 NO. 174, Cables & Cable Glands for use in Hazardous Locations CSA C22.2 NO. 38, Thermoset Insulated Wires & Cables (XLPE) CSA FT4, UL 1685 FT4, Vertical Tray Flame Flame XLPE (RW90 rated), 90 C wet/dry -40 C cold bend/impact rated HL rated for use in hazardous locations: - Class I Zone 0 (Intrinsically Safe cables only) - Class I Zone 1 (Div 1) - Class II Zone 20, 21 (Div 1) - Class II Zone 22 (Div 2) Black conductor (standard) Strand Bare (ASTM B8) Annealed Copper Conductor 2. XLPE (RW90 Rated) Insulated Conductor 3. Serve/Wound Grounds 4. Polyester Separator Tape 5. FR LAG PVC Inner Protective Jacket 6. Aluminum Interlocked Armour (AIA) 7. FR LAG PVC Outer Protective Jacket Ground Wire Size (uninsulated) OD Over Inner Jacket Normal Diameters (lbs/1000ft)/ Max. Pulling Tension (Pulling Eye) (lb/kg) Min. Bend Radius (Pull) 80210M / / / / / / M / / / / / / M / / / / / / M1/ / / / / / / / M2/ / / / / / / / M3/ / / / / / / / M4/ / / / / / / / M / / / / / / M / / / / / / M / / / / / / M / / / / / / / M / / / / / / / MA / / / / / / / 903 * value based on Canadian Electrical Code, Version 2012, Table-2. Values are corrected according to Table-5C for number of.
22 CSA TECK 90 V.2 22 POWER MULTI-CONDUCTOR (1000V) PAGE 1 OF 2 HL Unshielded armoured power cable is used to supply power for lighting, drives, motors and pumps. Interlocked armour replaces the use of conduit for mechanical protection. Cable can be directly buried, installed in raceways, including cable tray in wet or dry environments. Cable is suitable for use in outdoor exposed applications and is rated for damp or dry locations in -40 C (-40 F) environments V Optional: 600V rated: 90 C wet/dry Armour: - Aluminum Interlocked Armour (AIA) (standard) - Steel Interlocked Armour (SIA) (optional) - FR LAG PVC (AG14 rated) inner/outer black jacket - Variable Frequency Drive (VFD) - Verlock (for mineshaft applications) - Custom colour coding - Composite constructions - Aluminum conductors CSA C22.2 NO. 131, Teck 90 Cables (Teck 90) CSA C22.2 NO. 174, Cables & Cable Glands for use in Hazardous Locations CSA C22.2 NO. 38, Thermoset Insulated Wires & Cables (XLPE) CSA FT4, UL 1685 FT4, Vertical Tray Flame Flame XLPE (RW90 rated), 90 C wet/dry -40 C cold bend/impact rated HL rated for use in hazardous locations: - Class I Zone 0 (Intrinsically Safe cables only) - Class I Zone 1 (Div 1) - Class II Zone 20, 21 (Div 1) - Class II Zone 22 (Div 2) 2C Black & white 3C Black, red & white 4C Black, red, blue & white 5C to 50C Black # coded Strand Bare (ASTM B8) Annealed Copper 2. Grounding/Bonding Conductor 3. XLPE (RW90 Rated) Insulated 4. Polyester Separator Tape 5. FR LAG PVC Inner Protective Jacket 6. Aluminum Interlocked Armour (AIA) 7. FR LAG PVC Outer Protective Jacket Ground Wire Size (uninsulated) OD Over Inner Jacket Normal Diameters (lbs/1000ft)/ Max. Pulling Tension (Pulling Eye) (lb/kg) Min. Bend Radius (Pull) 80210M / / / / / / M / / / / / / M / / / / / / M / / / / / / M / / / / / / M / / / / / / M1/ / / / / / / / M2/ / / / / / / / M3/ / / / / / / / M4/ / / / / / / / M / / / / / / M / / / / / / M / / / / / / M / / / / / / M / / / / / / M / / / / / / 454 * value based on Canadian Electrical Code, Version 2012, Table-2. Values are corrected according to Table-5C for number of.
LEAD FREE FIREX. Interlock Armored Cables TECK90 and MC Industrial Cables. w w w. n e x a n s e n e r g y. c o m
FIREX Interlock Armored Cables TECK90 and MC Industrial Cables LEAD FREE O V E R 1 8 0 Y E A R S O F E X P E R I E N C E 866-663-9267 w w w. n e x a n s e n e r g y. c o m Interlock Armored Cables Introduction....2
More informationCIR. Index. Gexol. Standard CIR UL Listed Type TC-ER. Crush and Impact Resistant Without External Armoring. Arctic CIR UL Listed Type TC-ER-HL*
Gexol CIR Crush and Impact Resistant Without External Armoring Passes the same stringent crush and impact testing required by UL 2225 for Type MC-HL n Available in Standard and Arctic Grade Jackets n Highly
More informationUnarmored Variable Frequency Drive (VFD) Cable Termination Guide
Authorized Distributor Unarmored Variable Frequency Drive (VFD) Cable Termination Guide Be Certain with Belden A Step-by-Step Look at the Connection/Termination of Unarmored VFD Cables Terminating Unarmored
More informationPROFIBUS cable. PROFIBUS DP cables Non-Ex (Hazardous) applications Ex (Hazardous) applications
Data Sheet 10/63-6.47-EN Rev. D PROFIBUS cable PROFIBUS DP cables Non-Ex (Hazardous) applications Ex (Hazardous) applications PROFIBUS PA cables Non-Ex (Hazardous) applications Ex (Hazardous) applications
More information100% EMI Emission Containment
100% EMI Emission Containment Designed for Longer Service Life Highly Flexible for Easier Handling and Faster Installation Authorized Distributor Industrial VFD Cables Index n Variable Frequency Drive
More informationCONFLEX ELECTRIC CABLE
CONFLEX ELECTRIC CABLE CONFLEX - 0.6/1kV Flexible VSD/EMC Cables Applications WW VSD/EMC cables are manufactured for use where electrical interference distorts signal transmission in electric motors. Standard
More informationFire Resistant Cables
109/4 Fire Resistant Cables SR 114H Standard - SR 114E Enhanced BS 5839-1 BS 7629-1 BS 6387 BS 8434-1/2 BS 6425 BS 7622 EN 50200 World-wide recognized high quality cables Firecel SR114 are used in: Data
More informationServo Motor & Drive Cables
Servo Motor & Drive Cables Servo-Motor & Drive Cable Contents Servo-SM (Servo-Motor & Feedback Cables to Siemens Specifications) 970 SERVO-SM5-6FX5008-1BD.. UL/CSA/CE SHLD PVC Feedback Cable- Green 971
More informationIndustrial Cable Solutions for Variable Frequency Drives
Industrial Cable Solutions for Variable Frequency Drives Tough challenges call for innovative solutions, and General Cable is your worldwide source for new products and a wide range of industry-leading
More information2012 CATALOG AEROSPACE VVIRE & CABLE INC. aerospacewire.com
* 2012 CATALOG AEROSPACE VVIRE & CABLE INC. A VV aerospacewire.com W e p r o u d l y m a n u f a c t u r e h i - t e m p w i r e & c a b l e. PLENUM CABLE. INDUSTRIAL CABLE. TRAY CABLE. MILITARY WIRE.
More informationSpecification SFTP CAT6 Network Cable 23AWG CU
Specification SFTP CAT6 Network Cable 23AWG CU S/FTP CAT6 Shielded S/FTP PVC Cable 23AWG 4pair Solid, Wooden drum 1000 Grey CAT6 600MHZ CM Shielded (S/FTP) Solid Cable: Our CAT6 600MHZ Shielded (S/FTP)
More informationWhy FOUNDATION Fieldbus?
Product Bulletin PB 244-R3 Fieldbus Cables Fieldbus Tye A cables rovide installation flexibility in many different environments, including outdoors and where multile or extended cable runs are required.
More informationGulf Cable & Electrical Ind. Co.
CONTENTS INTRODUCTION PRODUCT RANGE I PRODUCT DATA TABLES Irrigation 1 Coaxial s for T.V/ Satellite Antenna etc 2 Data Transmission s - 4 pair 24 AWG 3 TELEPHONE CABLES Telephone cables CCP-LAP & CCP-LAP-SS
More informationDIVISION 26 - ELECTRICAL SECTION 26 05 20 CABLES FOR INSTRUMENTATION
DIVISION 26 - ELECTRICAL PART 1 - GENERAL 1.01 SUMMARY A. Section Includes 1. Instrumentation Cables 1.02 SUBMITTALS A. Submit in accordance with requirements of Section 01 33 00. B. Product Data: Submit
More informationInstrumentation Cable...14-17. Power Cable...2-11. Assembly Solutions...32
Severe Cold Durability Exceeds CSA Cold Bend / Cold Impact (-0 C/-35 C) Drilling Mud Resistant Flame Retardant Certified to IEC 9-3 (33-3A) and IEEE 580 Oil Resistant Assemblies...3-33 Ester Based Mud
More informationRoHS DATA, COAXIAL AND ELECTRONIC M.R. D A TA, C O A X I A L, ECOLGICAL Telecom Cables A N D EL E CTRON I C. Cables
RoHS DATA, COAXIAL AND ELECTRONIC D A TA, C O A X I A L, A N D EL E CTRON I C Cables Index SOLID MULTI-CONDUCTOR CABLES STRANDED MULTI-CONDUCTOR CABLES SPEAKER/ZIP WIRE THERMOSTAT CABLE FIRE ALARM CABLE
More informationCommunication, Signal & Data Cables
Communication, Signal & Data Cables Used for indoor installation and interconnection of transmission, telephone, telegraph and electronic equipment as well as media equipments www.alfanar.com Communication
More informationCCW Continuously Corrugated Welded Cable A RMORED CAB LE FO R HAZAR D O U S LOCATI O N S
CCW Continuously Corrugated Welded Cable A RMORED CAB LE FO R HAZAR D O U S LOCATI O N S OCTOBER 2014 CCW Servicing Industrial and Specialty Applications This catalog contains in-depth information on the
More informationGexol. Gexol. The Global Cable Solutions Company. Designed for safe, reliable performance in the harshest oil and gas operating environments
Gexol Gexol World Class World Class Designed for safe, reliable performance in the harshest oil and gas operating environments Power Control Instrument VFD The Global Cable Solutions Company Gexol World
More informationSpecializing in the cable business for over 38 years, PT. SUPREME CABLE
Specializing in the cable business for over 38 years, PT. SUPREME CABLE MANUFACTURING & COMMERCE Tbk. (PT. SUCACO Tbk) has grown steadly to become a largest and leading cable manufacturer, with international
More informationMarineTuff Offshore and Marine Cable Solutions
Offshore and Marine Cable Solutions Belden offers the industry s largest selection of industrial cables for offshore and marine certified applications Whether you are handling oil, natural gas or petrochemicals,
More informationCable Products HONEYWELL SECURITY & CUSTOM ELECTRONICS. Honeywell's Genesis Series provides a full range
HONEYWELL SECURITY & CUSTOM ELECTRONICS Cable Products Honeywell's Genesis Series provides a full range of low voltage cables for security, fire, sound, voice and data, video, structured cabling and other
More informationFire Alarm Cables. To do this, EVAC systems must remain operational longer than a total evacuation scenario or, as defined by code, for two hours.
is one of the original and leading manufactures or Fire Alarm cables in the world. Security and Alarm cables are a vital part of the building and construction industries. Security and FireAlarm cables
More informationExane 125 Drilling Rig and Commercial Marine Cable
Exane 125 Drilling Rig and Commercial Marine Cable Over 20 Years of Superior Perfomance On Oil Rigs Around The World Engineered Wire & Cable for Demanding Applications Certified as Type P per IEEE-45 STD
More informationCopper Cables CONNECTIVITY & CABLING SYSTEM
Copper Cables CONNECTIVITY & CABLING SYSTEM Category 5E M0502057-91 EN CPR 6707 U/UTP tested up to 200 MHz U/UTP CAT5E, unshielded 4-pair cable (100 Ohm), with PVC or LSZH (Low Smoke Zero Halogen) outer
More informationStandard Buccaneer - Ethernet
IP6 rated compliant PUR jacket on cable Shielded system shielded coupler Shroud on RJ45 Screw coupling Rewireable flex connector PCB mounted panel connector IDC termination panel connector Earth lead version
More informationSECTION 18370 SIGNAL WIRE AND CABLE
SECTION 18370 PART 1 - GENERAL 1.01 DESCRIPTION A. Section includes requirements for all cable and wire required for signal and signal power system wiring to wayside shelters, junction boxes, and factory
More informationKNOW YOUR OPTIONS: 230 KV POWER CABLES
KNOW YOUR OPTIONS: 230 KV POWER CABLES 71 CONDUCTOR MATERIAL AND SIZE Conductor material is a matter of both customer preference and required current carrying capacity At 230 kv, copper is most common
More informationCorporate Profile ROYAL. MODERN ROYAL ELECTRIC Ideal Power Solution MRE ELECTRICAL, INSTRUMENTATION & COMMUNICATION SYSTEMS
Corporate Profile MODERN ROYAL ELECTRIC Ideal Power Solution ROYAL MRE ELECTRICAL, INSTRUMENTATION & COMMUNICATION SYSTEMS MAJOR STOCKIST >>> CATHODIC PROTECTION CABLES >>> LOW VOLTAGE CABLES >>> MEDIUM
More informationFIRE RESISTANT CABLE CONSTRUCTION OF CABLES
FIRE RESISTANT CABLE In all fire disasters, fire smoke, heat and toxic fumes are the main obstacles to safe evacuation of a building or area. A major contribution towards overcoming these hazards is the
More informationIEEE POWER ENGINEERING SOCIETY CHICAGO CHAPTER THE OKONITE COMPANY WEDNESDAY JANUARY 11, 2006 JIM FITZGERALD ENGINEERING LINGO
IEEE POWER ENGINEERING SOCIETY CHICAGO CHAPTER THE OKONITE COMPANY WEDNESDAY JANUARY 11, 2006 JIM FITZGERALD ENGINEERING LINGO WHEN YOU HEAR AN ENGINEER SAY A NUMBER OF DIFFERENT APPROACHES ARE BEING IMPLEMENTED
More informationSection 5 161 kv Power Cables
Know Your Options: 161 kv Power Cable 61 material and size material is a matter of both customer preference and required current carrying capacity Copper conductor common for larger loads When both copper
More informationPROFIBUS cable. for PROFIBUS-PA and -DP 10/63-6.46 EN
for PROFIBUS-PA and -DP 10/63-6.46 EN CPN 080/CPE 080-Ex PROFIBUS-PA basis cable AWG 18, 0.88 mm 2 Use For fixed installation indoor and outdoor, on racks and in conduits. Application Fieldbus cable for
More informationETHERLINE Ethernet Cable, Connectors & Tools
Ethernet Cable, ors & Tools 2 Pair 242 4 Pair 249 Industrial Ethernet ors & Tools 256 Ethernet Cable, ors & Tools ETHERNET CABLE, CONNECTORS & TOOLS Quick Select Chart 240 2 Pair 2 Pair: CAT.5/5e; Stationary
More informationKNOW YOUR OPTIONS: 69 KV XLPE POWER CABLE
Know Your Options: 69 kv XLPE Power Cable 3 material and size material is a matter of both customer preference and required current carrying capacity Copper conductor common for larger loads When both
More informationThe Contractor shall furnish and install all shielded power cable suitable for use on this project.
Section 16122 PRIMARY POWER CABLES PART 1 GENERAL: WORK INCLUDED The Contractor shall furnish and install all shielded power cable suitable for use on this project. RELATED WORK Section 16020: Tests SUBMITTALS
More informationDATA SHEET SERVO LK SMS FX8PLUS SIGNAL
Application LAPP servo cables according to Siemens * (see footnote) Standard FX8008 PLUS SIGNAL are a new generation of very highly flexible screened signal (encoder and resolver)- cables (P/Ns 00277101
More informationMANUFACTURER S CERTIFICATE OF COMPLIANCE
s Type AC (Armored Clad) aluminum and steel interlocked metal clad 600-volt cable is produced 100% in the United States of America using accepted practices and quality assurance procedures to comply with
More informationThe Quality Connection. BETAflam Fire Resistant Safety Cables
The Quality Connection BETAflam Fire Resistant Safety Cables 2 Contact Consulting and sales Switzerland Phone +41 (0)62 288 82 82 Fax +41 (0)62 288 83 83 sales@leoni-studer.ch www.leoni-infrastructure-datacom.com
More informationCable Installation Notes
Cable Installation Notes June 2006 Table of Contents Cable Pulling... 2 Bending Radius... 2 Pulling Tension... 3 Friction... 3 Installation with Rollers... 4 Installation without Rollers... 4 Pulling Tension
More informationSecurity & Control Cables
Security & Control Cables Our multi-conductor cables are manufactured in a wide variety of gage sizes, shielding configurations and jacketing materials including plenum, riser and general purpose. Applications
More informationOutdoor Carrier Class Shielded Ethernet Cable. Datasheet. Models: PRO, CARRIER, Connectors. Increase Performance. Extreme Weatherproof
Datasheet Outdoor Carrier Class Shielded Ethernet Cable Models: PRO, CARRIER, Connectors Increase Performance Extreme Weatherproof ESD Damage Protection Extended Cable Support 1 2Datasheet Protect your
More informationMICROCABLES. A complete vision of your connectivity needs. Catalogue
MICROCABLES A complete vision of your connectivity needs Catalogue ELECTRONIC Filotex Introduction Application Nexans s line of microcables is designed towards the increasing requirements of electronics
More informationSerial Data Grade Cables
VGA INPUT MONITOR OUT VGA INPUT MONITOR OUT 3.5mm STEREO MINI 3.5mm STEREO MINI L R Audio L R Audio AUDIO INPUTS + - + - AUDIO INPUTS + - + - AMPLIFIED OUTPUT 4/8 ohm COM 70V 100V AMPLIFIED OUTPUT 4/8
More informationC 060 CCTV Coaxial Cable
C 060 CCTV Coaxial Cable These cables are used for video transmissons of CCTV applications..4...... Coaxial Cable (C 060).. Inner Conductor : Ø 0.60 mm Bare Copper.. Insulation : Ø.80 mm Gas-injected Foam
More informationA quick product finder for commercial applications JUDD WIRE INC. A member of the Sumitomo Electric Industries group of companies
A quick product finder for commercial applications JUDD WIRE INC. A member of the Sumitomo Electric Industries group of companies Select, Customize, Order & Receive Products with Ease This catalog contains
More information108-93018 05 APR 2016 Rev M
Product Specification 108-93018 05 APR 2016 Rev M Copper LAN Cable 1. SCOPE 1.1. Content This specification describes the general requirements for CommScope copper LAN cable. 2. APPLICABLE DOCUMENTS The
More informationRF & Microwave cable assemblies C291
ERTIFIED C AS 9100 RF & Microwave cable assemblies C291 B CONTENTS Pages Introduction... B-4 Specify the right cable for your application... B-5 Finder guide cables vs insertion loss... B-6 to B-7 Flexible
More information450-750 VOLTS - Copper conductor PVC insulated SSA 1320, IEC 60227 & BS 6004 HO 7V - U With Solid Conductor - TYPE 60227 IEC 01. Insulation Thickness
450 50 VOLTS Copper conductor PVC insulated SSA 320, IEC 6022 & BS 6004 HO V U With Solid TYPE 6022 IEC 0 For internal wiring equipment rated voltage up to 000 V AC and up to 50 V to earth. Catalogue Number
More informationType XHHW-2 or RHH/RHW-2/USE-2 GenFree II LSZH XLPO Single Conductor
TABLE OF CONTENTS SECTION I. SUBJECT SCOPE 2 II. APPLICABLE DOCUMENTS 2 III. CONDUCTOR 3 IV. SEPARATOR 3 V. INSULATION 3 A. 3-4 B. Electrical Properties 4 C. Flame Resistance 5 D. Smoke and Halogen Testing
More informationMarine & Shipboard Cable JIS C 3410(1999) IEC 60092-350, 353, 354, 376
T o t a l S o l u t i o n o f M a r i n e C a b l e Marine & Shipboard Cable JIS C 3410(1999) IEC 60092-350, 353, 354, 376 Marine & Shipboard cable Total Solution of Marine Cable JIS C 3410(1999), IEC
More informationSolar Power Solutions
Solar Power Solutions Wire and Cable Photovoltaic Connectors Combiner Boxes Fuses Grounding Power Connectors Physical Support Products Cable Ties Supply Chain Solutions Products. Technology. Services.
More informationPower and Wiring Cables
1 Single-Core PVC 1X...................... 1: Single-Core PVC/PVC 1Y.................. 1: Flat Twin & Flat Three Core PVC /Y........ 1: Multicore XLPE/LSF/SWA/LSF BS Control Cable.............................
More informationAutomotive Wire and Cable Products
Automotive Wire and Cable Products Primary Wires: ISO: Classes B - H JASO: AEX, AESSX, AVX, AVSSX : TXL, GXL, STX Engine Harness Wire: AutoRad Transmission Wire: Silicon & Non-Silicon Blocked Sensor Cables:
More informationVIPERFLEX ELECTRIC CABLE
VIPERFLEX Flexible Low Voltage Electric Cable - 0.6/1kV (Rubber insulated) H07 RN-F & H07 BN-F Single Core 2-Core 2-Core and Earth 3-Core and Earth 4-Core and Earth Multi-Core and Earth H07 RCN-F & H07
More informationThe Instrumentation Cable Experts
1 The Instrumentation Cable Experts Facilities Head office & factory 1300 Industrial Boulevard Mt Pleasant, Texas 75455, USA www.dekoroncable.com Stocking Centres USA Mt Pleasant and Houston Singapore
More informationOutside Telephone Cable
Outside Telephone Cable Filled Core. Moisture Barrier. Description Soft copper wires insulated with high density polyethylene, foam skin or solid. Filled core, conformed by groups of pairs or by unit of
More informationFlexible Control Cables
Works photo: KUKA Flexible Control Cables A Flexible Control Cables Since generations people try to build machines and plants which shall take on different functions. To raise, sink, slide, drill, transport
More informationMacArtney Underwater Cables - In stock
MacArtney Underwater Cables - In stock The MacArtney Group depends on the support of a number of major cable manufacturers to supply a range of cables that are designed, manufactured and tested to meet
More informationTS 813 GROUNDING AND BONDING TTD 813.001 TRAFFIC SIGNAL INSTALLATION AND CONTROLLER CABINET GROUNDING SYSTEM TTD 813.005 CONTROLLER CABINET GROUNDING
TORONTO TRANSPORTATION January 2012 TS 813 GROUNDING AND BONDING TABLE OF CONTENTS 1. DRAWINGS TTD 813.001 TRAFFIC SIGNAL INSTALLATION AND CONTROLLER CABINET GROUNDING SYSTEM TTD 813.005 CONTROLLER CABINET
More informationBroadcast and Commercial AV Cabling MASTER CATALOG
Broadcast and Commercial AV Cabling MASTER CATALOG Clark Wire & Cable 408 Washington Blvd. Mundelein, IL 60060 800-222-5348 toll free 847-949-9944 local 847-949-9595 fax www.clarkwire.com Specifications
More informationCommercial Coaxial Cable
Commercial Coaxial Cable For the Best in COMMERCIAL TV Reception Solutions! Do you require a Digital TV reception system for your next project? Matchmaster can supply For The Best Design and supply of
More informationInternational Electrotechnical Commission Standards
International Electrotechnical Commission Standards Standard IEC 60028 IEC 60038 IEC 60050-461 IEC 60055-1 IEC 60055-2 IEC 60092-101 IEC 60092-350 IEC 60092-351 IEC 60092-352 IEC 60092-353 IEC 60092-354
More informationCLEVELAND CABLE LOCATIONS
A WORLD POWER IN CABLE SUPPLY THE CABLE AND ACCESSORY CATALOGUE 2011 2 CLEVELAND CABLE LOCATIONS CLEVELAND CABLE LOCATIONS 3 As is illustrated within our catalogue, we stock a comprehensive range of cables
More informationCopper Cabling Infrastructure Offering
Copper Cabling Infrastructure Offering High-Speed Copper Cabling Systems The deployment of high speed cabling systems has been increasing rapidly as data centers enable their physical infrastructure with
More informationCABLES FOR PHOTOVOLTAIC SOLAR ENERGY INSTALLATIONS FOR CLEAN ENERGY
CABLES FOR PHOTOVOLTAIC SOLAR ENERGY INSTALLATIONS FOR CLEAN ENERGY One Company Connecting The World POWERFUL PRESENCE PRODUCTS PERFORMANCE PEOPLE General Cable has been a wire and cable innovator for
More informationSound, Alarm & Security Cable 7
Electronics Sound, Alarm & Security Cable 7 Index Page The sound and security industry in the United States has grown from a simple and unsophisticated business, begun some 45 years ago, to one which has
More informationRADOX railway cables acc. to EN 50264 and EN 50306. Edition 2009
RADO railway cables acc. to EN 50264 and EN 50306 Edition 2009 Bridging our know how Interdisciplinary knowledge The HUBER+SUHNER Group is a leading international manufacturer of electrical and optical
More informationINTERNATIONAL STANDARD
INTERNATIONAL STANDARD IEC 60502-1 Second edition 2004-04 Power cables with extruded insulation and their accessories for rated voltages from 1 kv (U m = 1,2 kv) up to 30 kv (U m = 36 kv) Part 1: Cables
More informationAFUMEX LSX LOW SMOKE ZERO HALOGEN SCREENED WIRING CABLES BS8436 BASEC APPROVED PRODUCT DATASHEET & APPLICATIONS GUIDE KEY BENEFITS:
PRODUCT DATASHEET & APPLICATIONS GUIDE BASEC APPROVED AFUMEX LSX LOW SMOKE ZERO HALOGEN SCREENED WIRING CABLES BS8436 KEY BENEFITS: BASEC approved for the full size range of BS8436 (1.0mm 2 to 2.5mm 2
More informationTFC/U-JIN Coaxial Cable Product Information Sheet Type: TU6T60-JVB
Type: TU6T60-JVB Dielectric 2nd Outer (w/optional Floodant) Series 6 Coaxial Cable Copper Clad Steel Foamed Polyethylene Dielectric Bonded AP Laminate Shield 60% Aluminum Braid "Life Time" compound AP
More informationHIGH SPEED COMMUNICATIONS PLENUM CABLE CATEGORY 5e CMP FEP JACKETED, PVC-FREE UNSHIELDED TWISTED PAIR (UTP)
Cable Specification Category 5e CMP HIGH SPEED COMMUNICATIONS PLENUM CABLE CATEGORY 5e CMP FEP JACKETED, PVC-FREE UNSHIELDED TWISTED PAIR (UTP) This cable specification complies with the electrical transmission
More informationCable Solutions for Servo and Variable Frequency Drives (VFD)
Cable Solutions for Servo and Variable Frequency Drives (VFD) Electric drive systems with continuous torque and speed control are widespread today. They allow an optimal adjustment of the drive with respect
More informationUnderstanding Shielded Cable
Understanding Shielded Cable Industrial applications such as the factory floor are typically electrically noisy environments. Electrical noise, either radiated or conducted as electromagnetic interference
More informationThe proof is here!! Ron Goethals, Philadelphia; June 18, 2014
The proof is here!! The proof is here!! The proof is here!! The proof is here!! The proof is here!! The proof is here!! Highly flame-retarded non-halogen bedding compounds show remarkable effects on: BURNING
More informationCoaxial Cable 5. Electronics
Electronics Coaxial Cable 5 Index Page Coaxial Solutions Guide 86-87 88-93 RG 8/U Type 94-95 96-99 To meet the needs of today s sophisticated, high-speed, wide bandwidth electronics over long distances,
More informationScottishPower Distribution Cables & Equipment. Metal Theft
ScottishPower Distribution Cables & Equipment Metal Theft April 2012 As an aid to deterring to metal theft this booklet has been put together to help identify the types of utility power cables and associated
More informationLUTZE Flexible Cable and Wire Management for Industrial Automation
USA Cable Solutions LUTZE Flexible Cable and Wire Management for Industrial Automation Control Cable Electronic Cable Actuator Sensor Cable BUS and Network Cable Motor Supply, VFD, Servo and Feedback Cable
More informationYour Only Solution for All Variable Frequency Drive Applications
ASD/VFD Cable System ASDBrochure.indd 1 Your Only Solution for All Variable Frequency Drive Applications 11/2/12 9:23 AM Inadequacies in Standard VFD Cables: EMC-Electro Magnetic Compatibility Electromagnetic
More informationWest Penn Wire. Access Control Systems and Cables WEST PENN WIRE CABLE WITH CONFIDENCE
West Penn Wire Access Control Systems and Cables Access Control Cables AWG Size CARD READER CABLES # of Cond. CMR Shielded CMP Shielded CMR Unshielded CMP Unshielded 22 4 3241 253241B 241 25241B 22 6 3270
More informationContact Hueson Corporation for additional information or details. http://www.huesonwire.com 38 Sutton Street Northbridge, MA 01534 508-234-6372
Hueson Corporation of Northbridge MA, a specialty wire and cable manufacturer has recently introduced a solution to a long term industry challenge in the Trailer Cable Industry. Their solution involves
More informationCOAX Cables Radio Frequency Cables
COAX Cables Radio Frequency Cables Contents Page Table of contents Pictographs General information Introduction Types and abbreviations Temparature range Construction Characteristics Special constructions
More informationwith coloured cores and overall copper screen UL/CSA... 17
CONTENT Cable Track Cables y SD 200 extremely flexible TPE/PUR data cable with coloured cores for continuous movement..... 6 y S 200 extremely flexible TPE/PUR control cable with numbered cores for continuous
More informationRGB Component Video Cable Bundled RGB Coaxial Cables Miniature and High-Flex Type
B R I L L I A N C E B R O A D C A S T C A B L E S 19.69 RGB Coponent Video Cable Bundled RGB Coaxial Cables Miniature and High-Flex RGB coaxial cables are used for sending red, green and blue signals through
More informationCTI TECHNICAL BULLETIN Number 9: A publication of the Cable Tray Institute
CTI TECHNICAL BULLETIN Number 9: A publication of the Cable Tray Institute Cable Tray Wiring Systems Have Many Cost Advantages Cost is usually a major consideration in the selection of a wiring system.
More informationMEDIUM VOLTAGE POWER CABLES
MEDIUM VOLTAGE POWER CABLES CONTENTS 1 GENERAL INTRODUCTION 4 TECHNICAL INFORMATION 15 25 35 45 Single Core XLPE Insulated PVC Sheathed Cables UNARMOURED CABLES COPPER UNARMOURED CABLES ALUMINUM ALUMINUM
More informationGenerator DoCKInG StatIonS
Generator DOCKING STATIONS TRYSTAR Portable Power Cable Cam to cam cable extensions 2000V, 100A-400A rated to NEC table 400.5 (B) All portable power cable sold is highly flexible and UL & C-UL or CSA Listed
More informationEcoFlex Cable. Smaller. Lighter. Tougher. 100% Recyclable.
EcoFlex Cable Smaller. Lighter. Tougher. 100% Recyclable. Total Performance, Completely Recyclable EcoFlex cable is Alpha Wire s newest innovation in control cabling. A true engineering breakthrough, EcoFlex
More informationMYTHBUSTING Takes on Shielded Cabling
MYTHBUSTING Takes on Shielded Cabling Herb Congdon Brian Davis Objectives Take on myths of shielded cabling and use modern-day science to show what's real and what's fiction - through trial and error actually
More informationBasic Cable Assemblies DELIVERING QUALITY SINCE 1952.
Basic Cable Assemblies DELIVERING QUALITY SINCE 1952. Cable Types Cable Types Hook-up & Lead Wire Most Basic 2 Cable Types Cable Types Twisted Pair Cable A type of cable that consists of two independently
More informationStandards Affecting a Premise T-1 Installation
Standards Affecting a Premise T-1 Installation The T-carrier system originated many years ago as a technology developed by AT&T. The intended use of the scheme was to increase the voice channel capacity
More informationAWG: Cat5e: Cat6: Cat6A:
Some of the terms used in the cable business can be vexing to even the most seasoned folks in the industry. If any of this terminology has ever made you scratch your head, you are certainly not alone.
More informationPressure monitoring equipment for oil-sf 6. bushings, type GOEK
Pressure monitoring equipment for oil-sf 6 bushings, type GOEK Installation and maintenance guide 5693 827-6 en, Rev. 3, 2002-01-30 This document must not be copied without our written permission, and
More informationOffshore Transformer Platform. Technical Standard. Energinet.dk. HV, MV, LV and Signal Cables and Cable Routing
Offshore Transformer Platform Technical Standard Energinet.dk HV, MV, LV and Signal Cables and Cable Routing ETS - 03 Rev. 1 Acadre doc. 44858-09 Revision survey Chpt. Description Revision Date Resp. -
More informationMicrophone and Musical Instrument Cable Overview
B R I L L I A N C E B R O A D C A S T C A B L E S 19.3 Microphone and Musical Instruent Cable Overview Flexible Microphone Cables Belden icrophone cable is used for connecting low level icrophones or usical
More informationCaledonian Submersible Pump Cables for Oil Industry >> IEEE 1018 >> IEEE 1019 >> API RP 11S5
Caledonian Submersible Pump Cables for Oil Industry >> IEEE 1018 >> IEEE 1019 >> API RP 11S5 Caledonian Windmill Cables COMPANY PROFILE Table of Content Caledonian, established in 1978, offers one of the
More informationFIRE RESISTANT CABLES FP200 GOLD
FIRE RESISTANT CABLES FP200 GOLD FIRE RESISTANT CABLES FP200 GOLD BS7629-1:2008 Certificate No 077f Certificate No 077k FP200 GOLD The original highly durable and dressable, easy to terminate and install
More informationFrom a single wire harness to an entire Electrical Distribution System (EDS), PKC delivers power where and when you need it.
CATALOG INDEX Introduction 2 Overview 3 PVC-Automotive 5 PVC-UL and CSA 6 XLPE-Automotive 9 XLPE-UL and CSA 10 Metric Wire 11 Automotive Battery Cable 12 Boat Cable 12 Introduction PKC Group PKC Group
More information600V Power Cable 600V SOOW SOW
600V Power Cable Type SOOW UL/CSA 90 C 600V Part AWG No of Insulation Jacket Nominal Wieght/Mft Number Stranding conductors Thickness Thickness O.D. Nom. 18 2 SOOW 18 AWG 2.30 71 18 3 SOOW 16/.010 3.030
More information1394 locking cables. Your locking cables for AVT IEEE 1394 cameras
Your locking cables for AVT IEEE 1394 cameras AVT locking cables are ideal for connection of IEEE 1394 cameras in any industrial application. The high quality cables guarantee low damping and best signal
More information