1 GIGABIT PoE Manageable Mosaic switch INSTALLATION AND USER GUIDE
2 Important Notice 2012 by Legrand This document provides the required information for the manageable Mosaic switch. It is intended for network administrators who are responsible for installing and setting up network equipment. This document contains confidential and proprietary information of Legrand and may not be copied, transmitted, stored in a retrieval system or reproduced in any format or media, in whole or in part, without the prior written consent of Legrand. Information contained in this document supersedes any previous manuals, guides, specifications, data sheets or other information that may have been provided or made available to the user. This document is provided for informational purposes only, and Legrand does not guarantee the accuracy, adequacy, quality, validity or completeness of the information contained in this document. Legrand reserves the right to make updates, improvements and enhancements to this document and the products to which it relates at any time without prior notice to the user. IN NO EVENT SHALL Legrand BE LIABLE FOR ANY INCIDENTAL, SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES WHATSOEVER, INCLUDING BUT NOT LIMITED TO LOST PROFITS, ARISING OUT OF OR RELATED TO THIS MANUAL OR THE INFORMATION CONTAINED HEREIN, OR THE USE OF THE PRODUCT, EVEN IF Legrand HAS BEEN ADVISED OF, KNOWN, OR SHOULD HAVE KNOWN, THE POSSIBILITY OF SUCH DAMAGES. Trademark Acknowledgement This document contains trademarks, trade names and service marks of Legrand and other organizations, all of which are the property of their respective owners. Warnings and Cautions Before configuring your device, please download the latest firmware from the following website and update your device with this firmware. Warning: for Telnet configuration please read chapter 8 Telnet before connecting. ELECTRICAL WARNING To avoid the possibility of severe and potentially fatal electric shock, never install electrical devices in a wet location or during a lightning storm. Only a qualified electrician should connect electrical devices. LASER WARNING If equipped with a laser based SFP tranceiver LASER WARNING Fiber optic port of the switch includes 1310/1550nm Class 1 laser components certified according to IEC transmitting invisible laser radiation. Fiber optic port DO of the NOT 0 stare into switch the beam includes or view 1310/1550nm directly with Class optical 1 laser instruments. components certified according to IEC Avoid direct transmitting exposure to invisible beam. laser radiation. Do DO not NOT remove stare into the the protective beam or covers view directly on the with fiber optical connectors instruments. until you are ready Avoid to direct connect exposure the fiber to beam. optic cables. When Do not dealing remove with the fiber protective optic cables, covers please on the ensure fiber optic that connectors the TX at one until end you of the are link ready is connected to to the the fiber RX optic at the cables. other end of the F/O link. When dealing with fiber optic cables, please ensure that the TX at one end of the link is connected to PORT the RX & SOCKET at the other WARNING end of the F/O link. The RJ45 ports are shielded RJ45 data sockets (Ethernet connections). They cannot be used as analogue telephone or other sockets. PORT & The SOCKET CLI (RS232) WARNING socket cannot be used for USB connections. The RJ45 ports are shielded RJ45 data sockets (Ethernet connections). They cannot be used as analogue telephone or other sockets. FOR INDOOR The CLI USE (RS232) ONLY socket cannot be used for II USB connections.
3 Table of Contents 1 Introduction Overview General Characteristics Manageable Mosaic switch Shipped Components Front & Side panel components LED Indications Remote Management Options Hardware Installation Overview Device Management Overview User Names / Access Levels and Passwords Management Passwords Scheme Launching the Embedded web interface Application via a Web Browser Using Radius Server Password Authentication Port Level Configuration Port Details and Status Configuring the Port Name Factory Default Port Settings Changing Port Settings Power over Ethernet (PoE) MAC Security QoS Embedded web interface Menu system Port Indications Device Configuration Menus System Device Information Inventory Power Supply Environment Factory Defaults RADIUS Server Remote Software Reset Features Menus Global Configuration VLAN Mode Q VLAN Membership Configuration Q Port Settings Port Based VLAN Transparent VID Rapid Spanning Tree Protocol (RSTP) Configuration IGMP Remote Device Configuration Configuration via the Terminal Emulation Application Configuring the IP and Community Parameters III
4 4.2 LAN Configuration via the LCS 2 - FTTO Init Application Running the LCS 2 - FTTO Init application Configuring the IP and Community Parameters Changing the Password Default Settings of the manageable Mosaic switch Restoring manageable Mosaic switch Default Settings Changing manageable Mosaic switch Factory Default Settings Restoring manageable Mosaic switch Factory Default Settings Configuring Active Management Interfaces Device Security Securing Management Access Community String / Passwords User Access Levels Management Access List Management Interfaces Management Access (Secure NMS) Path Securing Management Access via VLAN Web Management Userʼs Authentication Securing Network Access MAC Access Security - Securing User Access to the Network X Port Based Network Access Security Secure HTTP Protocol (HTTPS) Monitoring and Analysis Configuring SNMP Trap Destinations Device Level Event Log Viewing Recorded Events Event Filter Port Level Statistics and RMON Counters Port Monitoring Updating Firmware Versions General Local (CLI) Firmware Update Remote Firmware Update via LCS 2 - FTTO Init Remote Firmware Update via Embedded web interface LCS 2 - FTTO Bulk Firmware Update Firmware Licensing (in order to activate optional features) Activating the Special Add-on Feature(s) License Key Telnet General Run Telnet Invoking Telnet Help Selecting the static IP address of the device Changing User Level Passwords via Telnet Defining the Radius Server via Telnet Changing MAC Security via Telnet IV
5 Table of Figures Figure 1-1 manageable Mosaic switch... 7 Figure 1-2 manageable Mosaic switch Front view Figure 1-3 manageable Mosaic switch Side view Figure 3-1 Login Window via the Web Browser Figure 3-2 Port configuration, Properties and Status tabs Figure 3-3 Administration tab, Copper Port Configuration Figure 3-4 Administration & SFP tabs, SFP Port Configuration Figure 3-5 Port View Window, PoE tab Figure 3-6 Port View menu, MAC Security tab Figure 3-7 Port View menu, QoS tab Figure 3-8 manageable Mosaic switch Main Screen Figure 3-9 Close pop-up menu Figure 3-10 Apply pop-up menu Figure 3-11 Refresh pop-up menu Figure 3-12 System View menu, Properties tab Figure 3-13 System View menu, Inventory tab Figure 3-14 System View menu, Power Supply tab Figure 3-15 System View menu, Environment tab Figure 3-16 Thresholds window Figure 3-17 System View menu, Factory Defaults tab Figure 3-18 System View menu, RADIUS Server tab Figure 3-19 System menu, Commands tab Figure 3-20 Features menu, Global Configuration tab Figure 3-21 Features menu, VLAN Mode tab Figure 3-22 Features menu, 802.1q VLAN Membership tab Figure 3-23 Features Menu, 802.1q Port Settings tab Figure 3-24 Features Menu, Port Based VLAN tab Figure 3-25 Features Menu, Transparent VID tab Figure 3-26 RSTP Settings tab Figure 3-27 RSTP Ports Configuration tab Figure 4-1 COM Properties Window Figure 4-2 Hyper Terminal Boot Sequence Figure 4-3 LCS 2 - FTTO Init Discovery screen Figure 4-4 LCS 2 - FTTO Init Discovery screen - Discovered Devices Figure 4-5 LCS 2 - FTTO Init Password prompt dialog Figure 4-6 LCS 2 - FTTO Init Main Screen Figure 4-7 Changing the LCS 2 - FTTO Init password Figure 4-8 Changing Factory Defaults via Embedded web interface
6 Figure 4-9 Restoring Factory Defaults via Embedded web interface...55 Figure 4-10 Changing Management Interfaces...56 Figure 4-11 Changing Management Interfaces-Services...56 Figure 5-1 Management menu, Access List tab...59 Figure 5-2 Changing Management Interfaces-Services...60 Figure 5-3 Changing the Secured NMS Path...60 Figure 5-4 The Port View Window MAC Security tab...63 Figure X Access Authentication Scheme...64 Figure 5-6 Port View Window, 802.1X Tab...65 Figure X Access Authentication Enabled icon...66 Figure 5-8 HTTPS Enabled icon...67 Figure 6-1 Management menu, SNMP Traps tab...68 Figure 6-2 Event Log window...69 Figure 6-3 Event log with the Event Filter window...70 Figure 6-4 Port Statistics and Counters...72 Figure 6-5 Port View window, Monitor tab...73 Figure 7-1 LCS 2 - FTTO Init screen, Firmware Update commands...75 Figure 7-2 File Operations Window...76 Figure 7-3 LCS 2 - FTTO Bulk Source screen...77 Figure 7-4 LCS 2 - FTTO Bulk Targets screen...78 Figure 7-5 LCS 2 - FTTO Bulk Schedule screen...78 Figure 7-6 LCS 2 - FTTO Bulk Status screen...79 Figure 7-7 System Configuration window, General tab...80 Figure 7-8 Firmware License Tab...80 Figure 8-1 Telnet Commands...83 Figure 8-2 Telnet Help on specific command...83 Page 6 of 87
7 1 Introduction 1.1 Overview Figure 1-1 manageable Mosaic switch The manageable Mosaic switch is a high end fully manageable six-port installation (duct) switch. It is specifically designed for Fiber to the Office (FTTO) duct/trunk installations, floor tanks or hollow space sockets. The manageable Mosaic switch better suits networks requiring PoE functionality Main Feature list: Four external 10/100/1000M RJ45 A/N auto MDI ports 1x Gigabit/100M SFP F/O uplink and 1xRJ45 10/100/1000M daisy chain/uplink ports Power over LAN (PoE) option supports IEEE 802.3at/af PDs (PoE+, PoE) on all four RJ45 external ports High power embedded management providing SNMP agent, Web (full Java applet) and Telnet Remote management via Legrand's enhanced Embedded web interface application, Web browser and Telnet Highly secured in-band access via IP access list, secure NMS path, passwords and optional HTTPS Low voltage (52VDC) operation via compact external power supply The uplink ports of the manageable Mosaic switch are used for the network/backbone connections and support star, ring and daisy-chain topologies. The manageable Mosaic switch enables distributed network architecture. It provides efficient use of cable infrastructure and bandwidth using bandwidth aggregation for remote workgroups. The uplink ports enable connections to other workgroup switches from which additional devices can be cascaded. Thus, allowing the number of ports in the network center and cable infrastructure to be reduced for a simple installation and maintenance process. The manageable Mosaic switch is an advanced, full-featured switch with sophisticated attributes built-in. Optional features (802.1x per port access control & HTTPS support on embedded web interface) are available on demand. Please contact Legrand customer service. Page 7 of 87
8 1.2 General Characteristics Table 1-1 manageable Mosaic switch Characteristics Ports 1 to 4 (external user ports) F/O SFP Uplink Port 10/100/1000BaseT. Auto-negotiate, auto MDI, and polarity 100 meter (330 Feet) distance over TP cables Cat5e and higher Interface fiber optic SFP transceiver Provided with 1000 base-sx multimode (MM), 850/1310nm; connectors: SFP (LC) SC Accept also single-mode (SM) 1310/1550nm; connectors: SFP (LC) SC Compatible with 1000 base-sx 1000 base-lx RJ45 Uplink/daisy-chain Port QoS and VLANs 10/100/1000BaseT. Auto-negotiate, auto MDI, and polarity 100 meter (330 Feet) distance over TP cables Cat5e and higher QoS / CoS configuration with four traffic classes and prioritized packet streams per port. QoS based on IEEE802.3ac or IP TOS (supporting IPv4, IPv6) Q VLAN, support 64 VLANs, tag insertion and removal. Double tag support, Transparent VID. Access Security (per port) Port based MAC access security Q VLAN, port based VLAN 802.1X Port based network access control. Management SNMP management agent with in-band connection supporting SNMP, Telnet and Web Manageable via Telnet (IP) and Web. Three password protected access levels. Management Security Get Community and Set Community passwords. Management access list ("white" IP address list). Management access path. Management by specific VLAN. Management user authentication through up to four Radius servers for Web access. Spanning Tree support Page 8 of 87
9 Additional Features Monitoring RSTP/STP Spanning Tree support IGMP Snooping Event logging, filtering and sorting, prioritization and trap management (up to 8 trap destinations) with notification. Port level RMON and statistics. Port monitoring (mirroring) for data analysis / recording. Global device management Internal voltage and temperature measurement, thresholds and events. Control of switch learning and aging parameters. User's name assignment on device and port levels. Reset, configure and restore factory defaults via SNMP, Telnet and Web. Software download Remote firmware updating capabilities. Upload/download device configuration. Special features key activation. Set-up and testing Secured remote initial set-up via LCS 2 - FTTO Init (Legrand remote device initialization application). Power Supply AC input voltage: VAC, 50/60Hz Manageable Mosaic switch Power Consumption: - 8 Watts, without PoE - 60 Watts max with PoE Page 9 of 87
10 1.3 Manageable Mosaic switch Shipped Components The manageable Mosaic switch is shipped with the following components: Manageable Mosaic switch Mosaic power supply. 1.4 Front & Side panel components manageable Mosaic switch front panel contains LED indicators for Ports 1 4 as well as for the Uplink Ports (Power, Management and the PoE LEDs are also located on the front panel. Reset (1) Port 1 L/A & Port 2 L/A & User Identification Internal Port 3 L/A & Port 4 L/A & PoE LEDs PoE LEDs Marking Slides Push button PoE LEDs PoE LEDs CLI Connector (reserved) Uplink 1 RJ45 Port Uplink 2 SFP Port Power LED Main DC Power Management Connector LED Uplink 2 L/A LED Uplink 1 L/A LED Figure 1-2 manageable Mosaic switch Front view (1) To press the Reset button user needs to remove first the user identification marking slide. Use narrow tool such as needle to press the button. Keeping the button pressed for a long period (few seconds) will force to unit to switch to the default factory settings. Page 10 of 87
11 Cooling Plate Front Panel Uplink Uplink 1 RJ RJ45 45 Port ethernet port (2) Shield Terminal Uplink 2 SFP Port Main DC Power Connector Figure 1-3 manageable Mosaic switch Side view (2) The two RJ45 built-in LEDs, part of Uplink 1 RJ45 connector, are not active in the manageable Mosaic switch LED Indications Table 1-2 lists the LED indicators and their description. Table 1-2 manageable Mosaic switch LED Descriptions LED Indicators Description Power ON Main Power connected and power supply OK Network Management System (NMS) Uplink 1-2 L/A (Link Activity) PoE Ports 1-4 Ports 1-4 OFF ON OFF ON BLINKING OFF BLINKING ON OFF ON BLINKING Management startup/inoperable Management up and active no link link established on uplink port(s) activity detected (TX and / or RX) on the port(s) PoE / PSE disabled on the port PoE / PSE enabled, but PoE power not provided to the port (PD device not detected on the port) PD detected, PoE / PSE power (52VDC) provided to the port no link link established activity detected (TX and / or RX) on the port(s) Page 11 of 87
12 1.5 Remote Management Options The manageable Mosaic switch can be managed via any of the following two management interfaces: The Embedded web interface Web Management application - from any Web browser - as an applet Telnet connection Factory defaults configure all three management interfaces to be active. This configuration can be changed so that the device can only be managed by one or a combination of two management interfaces. Page 12 of 87
13 2 Hardware Installation 2.1 Overview The manageable Mosaic switch features a compact design with a low mounting depth that fits into standard 45x90 or larger faceplates and ducts. Installation of the manageable Mosaic switch includes the following recommended steps: Mount the manageable Mosaic switch external PS (Power Supply) in the duct and connect the PS to the main power Connect the DC connector of the PS to the manageable Mosaic switch (the manageable Mosaic switch should start booting) Performing initial IP configuration of the specific device: a. Connecting a PC/laptop via LAN cable to any manageable Mosaic switch port and setting the IP parameters via the LCS 2 - FTTO Init application. b. Connecting a PC/laptop via the manageable Mosaic switch special RS232 serial cable (optional) to the CLI connector of the manageable Mosaic switch, performing manageable Mosaic switch restart and following the options. After the IP parameters are set, connect the manageable Mosaic switch to the network (via the F/O uplink and/or copper uplink/daisy-chain ports) Page 13 of 87
14 3 Device Management 3.1 Overview The manageable Mosaic switch can be managed remotely through the Embedded web interface EMS (Element Management System) application via any Web browser or via Telnet. The Embedded web interface EMS application can be installed on any computer running a Windows 98 / 2000 / XP / Vista / 7 platform, Linux or Solaris. This software requires prior installation of the Java JRE1.6 minimum. Remote management can also be conducted from any Web browser which has access to the Legrand device network. The Web browser launches a complete Embedded web interface GUI using a Java applet (see Section 3.2). The device may also be managed via Telnet (see Section 8) User Names / Access Levels and Passwords Each Embedded web interface session, is accessed by logging in using one of three user names, representing access levels, and its respective password. Factory default passwords are available for each user name. User Name / Access Level Guest Admin Technician Service Center CLI password Default Password guest admin tech Not Available mypass Table 3-1 User name access level and password The four user names (access levels) are as follows: Guest Allows only monitoring and viewing the configuration and status information. Password, configuration and traps option are not accessible at this level. Default password is guest. Admin Allows access to all configuration options except for service options such as power supply thresholds and Technicianʼs password (accessible by Technician level). Default password is admin. Technician Allows access to all configuration options and to service options such as temperature and power supply thresholds. Also, login as a Technician to gain access to the System Configuration window Firmware Update tab. A Technician can change the password for all other user levels, and change default factory settings. The default password is tech. Service Center Not available in this version. Page 14 of 87
15 3.1.2 Management Passwords Scheme Legrand devices can be managed in several ways: with the Embedded web interface application, through Web access or via Telnet. Each way has its own password scheme as follows: When using the Embedded web interface application all user access level passwords are stored in the application and can be changed through it. Embedded web interface allows access to all Legrand manageable devices. The passwords for Web access to manage Legrand devices are stored in each individual device. They can also be stored in up to four Radius servers, allowing central password management. Passwords stored in the device can be changed via the Telnet command set http password (see Section 8) while passwords stored on the Radius servers are changed in the Radius server itself. Upon logging in to the device, the password is verified either according to what is stored in the individual device or, if configured to the Radius server, is authenticated by one of the Radius servers (see Section 3.2.1). NOTE: In the case where multiple Radius servers are present, authentication begins at the first Radius server in the Radius Server Index List. If that Radius server is not found, authentication automatically proceeds to the next Radius Server in the list. If a Radius Server is found, but does not authenticate the user, the authentication process is ended and no further search takes place. The Telnet connection and the CLI access use the same password (mypass is the factory default). This password can only be changed via the CLI connection, see section 8.3. For security reasons, Telnet sessions are automatically terminated after about 60 seconds of idle time and require reconnecting and login (see Section 8). 3.2 Launching the Embedded web interface Application via a Web Browser 1. Verify that your computer is connected to the same network as that of the manageable Mosaic switch unit to be managed. NOTE: The Embedded web interface Web application is a Java-based application. In order to use the Embedded web interface Web application, JRE (Java Runtime Environment) or JVM (Java Virtual Machine) must already be installed on your computer. Java is freeware and can be downloaded from: 2. This software requires prior installation of the Java JRE 1.6 minimum. Launch your Web browser. In the browser address bar type the IP address of the manageable Mosaic switch unit to be accessed and press enter. It may take a few seconds for the Java applet to load the Embedded web interface application GUI. Once completed, the Login window appears as shown in Figure 3-1. Page 15 of 87
16 Figure 3-1 Login Window via the Web Browser 3. Choose your user name according to the three user access levels available. (Guest, Admin, or Technician). (User access levels are described in Section 3.1.1). 4. Enter the appropriate default password guest, admin or tech. NOTE: User level passwords cannot be changed via the Web browser; they can only be changed via Telnet (see Section 0) or controlled by a Radius server. (Section 3.2.1). 5. Be sure that the Get and Set Community strings match the Community parameters of the target device, or change them accordingly. SNMP Get community public Section 5.1.1). SNMP Set community private (Community parameters are discussed in 6. Click Connect in order to see the Embedded web interface main screen. You can now manage the device (see Section 3.3) Using Radius Server Password Authentication Legrand manageable devices can be configured to seek user level password authentication from a central Radius server, such as from a Freeradius, Winradius or Radiator server, while logging in from a Web browser. The advantage of storing user level passwords in the Radius server is that if the Web management passwords are changed, they need to be changed only in the Radius server and not in each individual device. Telnet is used to direct a Legrand manageable device to seek password authentication from the Radius server while logging in from a Web browser. (See Section 0) 3.3 Port Level Configuration Port configuration is done via port view windows. To access the port view windows, in the Embedded web interface main screen, click the port icon and the portʼs view related window appears. NOTE: The name of the port view window matches the type of port. For example, clicking the Uplink port icon, will bring up the configuration window name is Uplink View; click Port 1, and the configuration window name is port 1 View, etc. The appearance of the configuration windows, and the available configurable port parameter options differ for copper and for F/O ports. When an option is not available for the selected port type, the tab is not displayed. Page 16 of 87
17 3.3.1 Port Details and Status The Port View screen shows information about the port, connection type and status. To view this information, click the Properties and Status tabs. Figure 3-2 Port configuration, Properties and Status tabs The Port View configuration window includes the following tabs, depending on port type. Table 3-2 Port Configuration Options Parameter Properties: Description Displays port description and connection type. Assigns a name to a specific port. Status: Provides visual indications of port status and activity. The indicators include Link, Activity and Collision. Administration: Contains the port status, speed, duplex, negotiation and flow control settings. Part of the parameters use scroll bars, for the user to select between available options Monitor: PoE Allows port monitoring to be enabled or disabled. Allows control of portʼs output power. (Not available for uplink ports Page 17 of 87
18 Table 3-2 Port Configuration Options Parameter MAC Security: Description Allows individual ports to be disabled. (Copper ports only) QoS: (Copper ports only) Statistics: SFP: (SFP ports only) Allows setting the Quality of Service parameters of the port. Displays various statistics regarding traffic, port usage, and packets. Contains specific information concerning the type of SFP connector in the port, including type, bit rate, wavelength, vendor, model type and serial number NOTE: On SFP ports, the connector type and other physical descriptions of the port are found in the SFP tab only, and not in the Properties tab Configuring the Port Name Each port can be named in order to identify the user or device connected to that port. In the specific Port View window, click the Name field to enter the new value and then click Apply Factory Default Port Settings The device ports are factory preset with the following default values: Table 3-3 Factory Default Port Configuration Values Parameter 10/100/1000BaseT copper ports: Description Status On Auto Negotiate Enabled Speed Depends on A/N results Duplex Depends on A/N results MDI Auto Flow Control Enabled PoE Disabled on external user ports Page 18 of 87
19 Table 3-3 Factory Default Port Configuration Values Parameter F/O SFP Uplink port: Description Port Status On Auto Negotiate Enabled Speed Depends on A/N results Duplex Depends on A/N results Flow Control Enabled Changing Port Settings Figure 3-3 Administration tab, Copper Port Configuration To change the port settings 1. From Port View, expand the Administration tab. 2. Change the appropriate parameters with new values and click Apply. The left side of the field consists of the parameter set by the user (Admin). The parameters on the left side reflect the configuration identified by the operant (Oper) Table 3-4 Administration tab, Copper Port Parameters Page 19 of 87
20 Copper Port Parameters Status Mode Description Disables / Enables the port; Options: On, Off Port speed and duplex setting. --Auto-negotiate the port is set to negotiate speed and duplex mode with the link partner. --Manual speed and duplex are manually defined. Usually used when connecting to devices which do not support auto-negotiation or when link parameters must be forced. Auto Neg. Type Speed Select the type of Auto Negotiation Preferred/Forced Master/Slave Applicable if auto-negotiation is set to Manual. Options: 10M, 100M, 1000M. Duplex Applicable if auto-negotiation is set to Manual. Options: Full duplex, Half duplex. MDI/MDIX --Auto Negotiate Three advertise possibilities: 1) MDI and MDIX, 2) MDI, 3) MDIX --Manual Two possibilities: MDI or MDIX Flow control Enables / Disables flow control. In case of SFP F/O port, the properties port description will be SFP 1000BaseX Fiber Port or SFP 100BaseFX Fiber Port. The following figure list the Administration and SFP tabs, for the SFP port configuration Page 20 of 87
21 Figure 3-4 Administration & SFP tabs, SFP Port Configuration Table 3-5 Administration & SFP tabs, SFP Port Parameters Administration & SFP Description Port Parameters Status Disables / Enables the port; Options: On, Off Speed Displays 1000M or 100M, in accordance with the SFP plugged in transceiver. Otherwise, it is kept in Auto. Oper field displays the actual speed value, once it is established with the F/O link partner. Duplex When the system detects 100Mbit SFP it enables Full/Half Duplex setting for the port. Otherwise, it is kept in Auto Oper field displays the actual value, once it is established with the F/O link partner. Note; The following SFP Port Parameters are read from the plugged in SFP Transceiver Connector Bit Rate Wavelength Vendor Name Model Type Identified type of connector Identified bit rate Identified wavelength Identified Vendor Name, Model Type and Serial Number Page 21 of 87
22 Administration & SFP Port Parameters Serial Number Temperature Tx Power Rx Power Description Monitored Transceiver internal temperature. (data available only if the SFP transceiver supports DDM (Digital Diagnostic Monitoring) Monitored Transceiver Transmitted Power. (Data available only if the SFP transceiver supports DDM (Digital Diagnostic Monitoring) Monitored Transceiver Received Power. (Data available only if the SFP transceiver supports DDM (Digital Diagnostic Monitoring) Power over Ethernet (PoE) On the main GUI main screen a PoE LED image appears above each PoE capable copper port. In addition, in the Port View window a PoE tab appears. The manageable Mosaic switch provides 802.3at/af (PoE+, PoE) Power Source Equipment (PSE) capabilities with a total power capacity of up to 50 Watts on the ports. When an 802.3at/af PD device is connected to the port, the port detects and classifies the device according to the 802.3at/af standard and activates the PSE accordingly. If the PD device is not 802.3at/af complaint, it will not be recognized and the port will not supply PoE power to the PD. The monitoring and management of the PoE operation of the ports is done from the PoE tab in the Port View window PoE Management and Operation Tab If a port is PoE Capable, the PoE tab of the Port View window appears (this tab is not there in a non-poe port). From this tab one can turn the PoE option on and off, configure the disconnect mode, monitor general PoE characteristics and power consumption, and reset the PoE. Figure 3-5 Port View Window, PoE tab Table 3-6 PoE Parameters Page 22 of 87
23 Parameter Status Description The left selection tab indicates that the port is open for PoE connections (will supply power if a PD is connected). The right field indicates whether or not power is being supplied to the port. An ON indication appears when a PD is detected and the PSE power is provided to that port. An OFF indication is when PSE power is not provided to the port due to several possible reasons: 1) if the Admin Status is OFF (PoE is disabled on the port) 2) nothing is connected to the port, 3) the device connected to the port is not an 802.3at/af PD device. Reset Pressing this button disconnects the PSE Power for about 5 seconds and then automatically re-connects it providing remote power reset to the PD device. Disconnect Type/PD Class Select between AC Disconnect or DC Disconnect mode in the port configuration window. Selecting DC Disconnect enables detection only of DC PDs (the most common type of PDs currently). Select AC Disconnect enables detection only of AC type PDs (mostly old PDs). The default is DC Disconnect. Indicates the 802.3at/af power classifications of the device connected to the manageable Mosaic switch port. The type is indicated by dot3af or dot3at (meaning 802.3at/af) and ClassX (to indicate which class is connected). In the above example, no device is connected to the manageable Mosaic switch, consequently the PD Device Type indicates Class-0 (Load Not Detected) which is the default indication. (See following table.) Min Power PoE PoE+ Min Power Levels at Class Class Levels at PSE 802.3af 802.3at PSE output output Watts Watts Watts Watts Watts Watts Watts Watts 4 As Class Watts Page 23 of 87
24 Table 3-6 PoE Parameters Parameter Consumption Voltage Description Displays the actual power being consumed by the PD device connected to the port. Displays the voltage supplied by the PoE Power Supply to the manageable Mosaic switch PoE Power Capacities The total power capacity of all four PoE ports combined cannot exceed 50 Watts. Consequently, when connecting PD devices to the ports, the device detects its class and provides PSE power to the port only if the device can allocate enough power to that port within the total 50 Watt limitation manageable Mosaic switch PoE LED Indicators The existence of the LED itself indicates that the port is PoE Capable. Ports with no PoE capabilities have no PoE LEDs. On a PoE capable switch there are three possible PoE LED indications: OFF, BLINKING and ON (steady illumination). A: PoE LED OFF: Indicates that PoE is administratively disabled on this port. This can be changed through the PoE tab in the Port View window. B: PoE LED BLINKING: Indicates that PoE is enabled on the port, but no PD is connected. C: PoE LED ON (steady illumination): A PD device is detected on the port(s) and PSE power is provided to those port(s) MAC Security There are two modes of MAC security: MAC Access Security is locally authenticated according to the approved MAC The Approved MAC is authenticated by the Radius server before continuing with the MAC Access Security process. The MAC security mode is selected only through the Telnet application. See Section 8.5. Page 24 of 87
25 Figure 3-6 Port View menu, MAC Security tab MAC Security Configuration Fields: MAC Address 1-3 list displays the MAC address entries belonging to that port in the look-up table. Approved MAC field displays the specific MAC address to be secured (the MAC address according to which the MAC security algorithm works). Mode field displays the MAC security operation mode (disabled, low security or high security). Status field displays the port security status (disable, port forwarding, or port blocked). When disabled appears in the Status field, this means that the MAC security is disabled. When port forwarding or port blocked appears in the Status field, this means that the MAC security is enabled and that specific port is either forwarding or blocked in accordance to the MAC security algorithms. NOTE: Port Monitoring, MAC security and 802.1X cannot be active at the same time. 1. In the Approved MAC list select the MAC address to be designated as the approved MAC address. 2. Open the Mode list and set the mode according to the following parameter descriptions: Disable MAC security is not enabled. Low Security Level The port is open (forwards data) for all devices as long as the approved MAC address exists on the port's look-up table. When the designated device is disconnected and its MAC address is removed from the port table, the port blocks data communication to all devices. High Security Level Only the designated approved MAC address can use the port (i.e., only the approved MAC address exists on the portʼs look-up table). If the port receives frames from another device (other addresses in the look-up table), then the port blocks all data transmission, even for the approved address. NOTE: When a port is blocked through MAC Security it is detected as a major event and an appropriate trap is sent to the authorized SNMP managers QoS The packet flow through each port is defined by the Ingress / Egress Policy. manageable Mosaic switch Page 25 of 87
26 provides three criteria that determine the policy: QoS priority information Rate Limit 802.1Q based VLANs QoS Priority Definitions The manageable Mosaic switch uses an advanced non-blocking, four priority output port queue architecture. Frames exit the switch using a weighted, fair queuing scheme in which 8, 4, 2, 1 is applied to the four priority output queues: eight frames from priority 3 egress, followed by four frames from priority 2, etc. Ingress frames are queued to the proper output queues according to their priority. The frame priority is determined either in the 802.3ac tag or in the TOS field. Figure 3-7 Port View menu, QoS tab QoS priority definition criteria Default PRI (priority level) Sets the priority level of ingressing frames arriving without a priority level (four priority levels: 0-3). Ingress 802.3ac Enables queuing of ingressing frames with 802.3ac tags containing 802.1p priority information to be queued accordingly. Ingress TOS (Type of Service) - Enables queuing of ingressing frames with IPv4 TOS / DiffServ or IPv6 Traffic Class priority to be queued accordingly. NOTE: If both Ingress IEEE 802.3ac and Ingress ToS are enabled, and a frame arrives with both types of priorities set, the frame will be queued according to the IEEE 802.3ac information Rate Limit Definitions Frames enter (ingress) the port at the rate limit allocated to their identified priority level. Frames without a priority level, enter the switch at the rate limit assigned to the port (default PRI parameter). All frames exit (egress) the port at the Egress rate limit. The manageable Mosaic switch support progressive Ingress rate limits for four priorities, where the rate for each priority level is relative to the previous level. Only Priority-0 is assigned a value. For example, if Priority 0 rate is set to 8 Mbps, then priority 1 rate may be the same or double that of Page 26 of 87
27 priority 0, priority 2 rate is the same or double that of priority 1, etc. To define QoS Rate Limits: 1. Click on the Ingress PRI0 field to set its value, or on Ingress PRI1 through Ingress PRI3 to set their value according to PRI0. Table 3-7 Rate Limit Parameters Parameter Available options Egress rate: Not limited or Limited to one of the defined rates between 128 Kbps to 8 Mbps (128K; 256K; 512K; 1M; 2M; 4M; 8M) Ingress PRI 0: Unlimited or in seven steps to a value between 128 Kbps to 8 Mbps (128K; 256K; 512K; 1M; 2M; 4M; 8Mbps). Ingress PRI 1: Same as PRI 0 or double (i.e. unlimited up to 16 Mbps depending on PRI 0 settings). Ingress PRI 2: Same as PRI 1 or double (i.e. unlimited up to 32 Mbps depending on PRI 0 & 1 settings). Ingress PRI 3: Same as PRI 2 or double (i.e. unlimited up to 64 Mbps depending on PRI 0, 1 & 2 settings) The manageable Mosaic switch also supports different Rate Limit Criteria when counting packets. The switch can count all packets, broadcasts, multicasts and FUcasts in some combinations. To define the Rate Limit Criteria: 1. Click the Rate Limit Criteria field and select the appropriate value from the list. Page 27 of 87
28 3.4 Embedded web interface Menu system The Embedded web interface main screen provides all devices and port configuration screens plus a summary of events and fault analysis options. The screen provides a graphic view of the manageable Mosaic switch device including color indications on ports and LEDs to indicate status, as in Figure 3-8. Manageable Mosaic switch module may be placed horizontal or rotated vertically, yet the screen graphic will always appear as in Figure 3-8. Figure 3-8 manageable Mosaic switch Main Screen The top left side of the screen consists the deviceʼs identifying information such as its IP address and user's defined name, location and contact person. These names are only used to identify the device to an administrator or technician. See Section Erreur! Source du renvoi introuvable. for information on how to change these fields. Next, on the left side of the screen are the Device configuration icons: System, Features, Files, Users, Management and Relogin which provide the following options: Menu Option Description Provides access to the following tabs and fields : ß Properties Description, Uptime, Name, Location, Contact ß Inventory FW Version, HW Revision, Loader Version, MAC Address, Serial Number, PoE Module, Max. PoE Pwr, Manuf. Date ß Power Supply Type, Model, Nominal Power ß Environment Temperature, Internal Voltage, access to Thresholds settings ß Factory Defaults User's Port Status (select On or Off), Backbone VLAN (select Enable or Disable), access to the Restore command ß RADIUS Server Radius Server IP Addresses, Shared Secrets, Auth. HTTP Users ß Commands Provides access to the Reset Device command Page 28 of 87
29 Menu Option Description Provides access to the following tabs and fields: ß Global Configuration Aging (16 Sec; 300 Sec; 1800 Sec; or No Aging), Learning (select Enable or Disable), PONL (not available), Priority Policy (select Scheduled 8421 or Scheduled 1111). ß VLAN Mode Select VLAN Disabled, 802.1q VLAN Enabled, Port Based VLAN Enabled ß 802.1q VLAN Membership Shows a list of VLAN members, and provides a dialog to either Add or Delete entries ß 802.1q Port Settings Provides a table view for port settings ß Port Based VLAN Provides a table view of Port based VLAN settings with option to select or clear all ß Transparent VID - Provides a table view of Port based VLAN settings ß RSTP Settings Priority, Designted Root, Root Cost, Root Port, Bridge Max. Age, Bridge Hello Time, Bridge Fwd. Delay ß RSTP Ports Configuration - Provides a table view of the RSTP Ports Configuration ß IGMP Snooping Configuration Status (Enable, Disable), Join and leave Messages ß IGMP Snooping Discovered Configuration - Provides a table view of the IGMP Snooping discovered Ports Configuration ß Provides access to the following tabs and fields :Files List the Type, Name and Size of the file ß Operation File name, Status, Progress and Command bar to allow manual downloads of files from remote servers, or uploading of a local config file ß File Server FTP IP Address, User Name and Password Allows changing user passwords for Embedded web interface (Only accessible through the Stand-Alone program). Includes the following management tools: ß Traps IP Addresses of Trap Destinations ß Access List IP Address access list ß Management Interfaces (Telnet/Web/SNMP) ß Secure NMS Path options ß License details (Features and Key) ß About Embedded web interface Version iformation Allows signing in as a different user and/or to a different device, without completely restarting the program (Accessible only through the Stand-Alone program). Table 3-8 Device configuration options The device level configuration options are accessed by clicking the appropriate icon on the left side of Page 29 of 87
30 the screen. The port level configuration menus are accessed by clicking on the specific port in the graphic view Port Indications The manageable Mosaic switch main screen displays color-coded port management characteristics through icons and LEDs that indicate the status of each port). Note; Management of the device relates to port numbers, and not necessarily to the default visual display. Table 3-9 Color and icon Indications Copper Port connector Icons and Colors: Grey No connection / link Green Link without activity Yellow Link with activity (Normal operation) Red Collisions Red X on the port icon (top left corner) Port administratively closed. HTTPS icon (HTTPS enabled) Fiber Port connector icons: Four colors: grey, green, yellow and red to indicate port status, same as for the copper port.. The F/O port uses different icons to reflect connector type: Duplex SC Duplex ST SFP Empty SFP Simplex (SC) MAC access and 802.1X security icons on copper ports: A lock icon within a port icon indicates that either MAC or 802.1X Network Access Security is enabled. Grey with Green lock Security enabled on the port, port access is open Page 30 of 87
31 Green with Red lock Port connected and blocked by the activated security NOTE: Red lock icon is used in case of two blocking events. First when 802.1x port is enabled by manageable Mosaic switch but not yet authorized. Second is when MAC security mode is enabled but the MAC address is not authorized. In the two case events, once the port is authorized, the lock icon change from red color to green The manageable Mosaic switch main screen provides also LED indication on manageable Mosaic switch unit and port status. Table 3-10 lists the LED indication through the GUI: Table 3-10 LED Indications LED ON OFF L/A (Link/Active) Ports 1-4, Uplink Ports U1, U2 PoE Ports 1-4 Port connected (link established). PoE power provided to the port (PoE enabled, and PD device connected to the port). LED blinking specifies PoE enabled but no PD device Port not connected. PoE power is NOT provided to the port.(poe disabled) NMG Managed device, management agent active. Unmanaged device or management agent inactive. Power Power is being supplied to the unit. Power is not being supplied to the unit. Page 31 of 87
32 3.5 Device Configuration Menus The icons on the left provide device level information and configuration options. Clicking the appropriate icons will open the requested information/configuration window, to enable configuration of the manageable Mosaic switch unit. Each configuration page includes several tabs. Double click on tab will enable access to all configuration parameters. Fields within the specific page contain bars with either information data (no editing option), command line to type a required value or scroll bar to select between available options. The following three bars are used in all menu pages: Close Close page menu. Closing the page without save of the changes will pop up a menu for the user to assure if the changes should be lost. Click Yes to ignore changes and leave page. Click No to return back to page. Figure 3-9 Close pop-up menu Apply Save new setting parameters. In case changes in setting parameters, a popup menu will verify if the user wants to save the changes. Click No to ignore changes or Yes to save changes. Figure 3-10 Apply pop-up menu Refresh Used to refresh displayed page with the latest saved parameters. In case of any change in setting parameters, a pop-up menu will verify if the user wants to keep or ignore changes. Clock Yes to ignore changes or No to keep displayed changes Figure 3-11 Refresh pop-up menu Page 32 of 87
33 3.5.1 System Device Information Figure 3-12 System View menu, Properties tab The Properties tab of displays the device Description, Up Time and allows Name, Location and Contact information to be assigned to the device. Assigning these device details helps the system manager locate and identify devices in the network. It is recommended to assign such details to each unit. To define device information: 1. Click on the System icon and select the from the System View menu the Properties tab Click on the Name field. 2. Edit the Name, Location and Contact fields. 3. Click Apply. 4. Text updated is displayed in Blue to indicate data is not send yet to the device. Once the user clicks Apply, data is send to the device and field color data is changes to black. Page 33 of 87
34 3.5.2 Inventory Figure 3-13 System View menu, Inventory tab The Inventory tab displays information about the device hardware. Max PoE power specifies the maximum power that may be sourced through the portʼs PoE Power Supply Figure 3-14 System View menu, Power Supply tab The Power Supply tab displays information about the power supply type, model and the nominal power of the unit Environment Figure 3-15 System View menu, Environment tab The Environment tab displays the current operating temperature of the device, as measured on-board voltage of the device. The temperature and voltage limits, set for the unit, define the alert thresholds. The limits can be modified by a Technician level user at any time. The temperature thresholds should only be changed if the installation/operation environment requires that. The factory setup relates to operation in a 25 C environment. The default temperature threshold is 55 C. The default voltage threshold ranges between 3.15 V (low) and 3.45 V (high). Page 34 of 87
35 NOTE: It is not recommended to change the default voltage thresholds. Threshold alerts are only generated when the limits are crossed. To change the Temperature or Voltage limits: 1. Enter the Management application at a Technician level. 2. Click on the System icon and select the from the System View menu the Environment tab. 3. Click Thresholds bar at the Environment tab. Figure 3-16 Thresholds window 4. In the Thresholds window, enter the new Temperature and/or Voltage thresholds and click OK. Allowed values are: Temperature: 0 C - 90 C Low voltage minimal value: 3100 High voltage maximal value: Factory Defaults Figure 3-17 System View menu, Factory Defaults tab The unit default parameters can be restored at any time. NOTE: This can also be done through Telnet (see Section 8) and LCS 2 - FTTO Init. Restoring the factory default settings will not affect the IP configurations or the Get / Set Community settings. To reload the unit default parameters (from a Technician or Administrator level only): 1. Click on the System icon and select the Factory Defaults tab 2. Select desired values for User port status (On/Off), backbone VLAN (Enable/Disable) and backbone VID. Click the Restore button. Verification prompt appears. 3. Click Yes to confirm. 4. Restart the device, either through the Remote reset option or through the LCS 2 - FTTO Init software. The new settings are applied after Reset. Page 35 of 87
36 3.5.6 RADIUS Server Figure 3-18 System View menu, RADIUS Server tab The RADIUS Server tab displays the current RADIUS server details. RADIUS server details can be edited from a Telnet connection. RADIUS authentication supported EAP-MD5 only Remote Software Reset The unit may be remotely reset at any time. Reset is required, for example, after a new software version is uploaded. (The unit may also be locally reset by disconnecting and reconnecting the power or pressing the front panel Reset push button, located at the left corner of the right user identification marking slide. For more details see Figure_12). NOTE: Reset can also be done through Telnet (Section 8). Figure 3-19 System menu, Commands tab To reset the unit (from a Technician or Administrator level only): 1. From the Commands tab, click Reset Device. A confirmation window appears. Click Yes to confirm. 3.6 Features Menus Global Configuration Learning - Switch Learning is always enabled and cannot be configured in this device. Aging time. Aging time can be set to 16 seconds, 300 seconds (5 minutes), 1800 seconds (30 minutes) or No Aging. The Factory default aging settings is 300 sec. NOTE: No Aging means the MAC addresses in the look-up table will not be removed automatically Priority Policy Set the desired priority to select between two options 8421 and In case of 1111 there is equal priority in the queuing and forwarding frames. In case of 8421, a weighted fair queuing scheme is applied to the four priority output queues: eight frames from priority 3 egress, followed by four frames from priority 2, followed by two frames from priority 1 Page 36 of 87
37 and last one frame from priority 1. If level of forwarding is similar between the ports, it is recommended to use priority option Otherwise, use PONL Not relevant to this product. It is for the user to set the right configuration of Aging time and Priority policy in order to enable the most efficient network performances, according to the application that runs on the network and the type of devices connected to the specific ports. The switch maintains an updated MAC address look-up table by continuously learning and flooding. The switch can be configured to remove unused addresses or those that are not used for a specified period (via aging time) so that time is not wasted forwarding to an irrelevant port. Each new look-up table entry is given a timestamp. Every time a packet is received from a node, the timestamp is updated. The entry is erased from the look-up table; after the user configurable length of aging time with no activity from that node (MAC address) has elapsed. Setting a too short value for aging time may cause addresses to be removed prematurely from the table. In this case, when the switch receives a packet for that destination, it floods the packet to all ports. This unnecessary flooding can impact network performance. Setting too long an aging time can cause the address table to be filled with unused addresses; it can cause delays in establishing connectivity when a workstation is moved to a new port. Address migration capabilities when a device is moved to a differed port in the same switch, the move is identified by the switch, after the first transmission from the device, and the MAC table immediately updates without aging as soon as the connected device transmits signals. Figure 3-20 Features menu, Global Configuration tab VLAN Mode The IS-2 supports 802.1Q VLANs and Port Based VLAN. Before a VLAN can be defined, the VLAN type must be selected from the VLAN Mode tab. Figure 3-21 Features menu, VLAN Mode tab NOTE: Only one type of VLAN setting can be active at any given time. If 802.1q VLANs are enabled, the Port Based VLAN (port forwarding table) is Disabled, and vice-versa. Port-based VLAN is similar to private VLANs in Cisco terminology, where are 802.1q VLAN is close to switchport access/trunk modes in Cisco terminology. Page 37 of 87
38 Q VLAN Membership Configuration The 802.1Q VLAN Membership tab defines the VLAN IDs (VIDs) and the port membership for each of the VLANs. For practical reasons, only up to 64 VLANs may be defined in the IS-2, with VIDs ranging from 1 to Before a VLAN can be used on the switch, its ID must first be defined in the VID list below, then all ports that will participate in this VLAN will be checked against this VID. For an access port, only one VID should be associated with a given port, for a trunk port, all VLANs carried over the trunk should be associated with the trunk port. Figure 3-22 Features menu, 802.1q VLAN Membership tab To configure VLAN membership 1. Click on the Features icon and select from the Features menu the VLAN Mode tab, Select 802.1q VLAN Enabled. 2. From the 802.1Q VLAN Membership tab, click Add. A prompt appears, requesting a New VLAN ID number. Enter a number that is not currently used by an existing VLAN, then click OK. 3. Now that the new VLAN appears on the 802.1Q VLAN Membership tab, check all the ports to be included in the VLAN and click Apply. To delete a VLAN: Select that VLAN from the list in the 802.1Q VLAN Membership tab and click Delete. The VLAN is deleted without verification. To edit a VLAN: Click on the ports to edit, set the required changes and click Apply Q Port Settings The 802.1Q Port Settings tab should reflect the condition (tagged/untagged) of the traffic expected on the associated port. Page 38 of 87
39 For an access port, the default VID for the port should match with the only VID associated with the port in the previous tab (802.1Q VLAN Membership). Egress Tag remove should also be checked, and Egress Tag Insert should be left unchecked. Ingress Tag Remove can be checked if traffic might arrive with a VLAN tag on the port, in which case the Default VID will not be used, and the VLAN ID for each tagged frame will be the one contained in the frame. For a trunk port, the default VID for the port should be the native VLAN ID. Egress Tag remove should be left unchecked, and Egress Tag Insert should be checked. If VLAN can be carried over another VLAN tag, Egress Double Tag Support can be checked. Figure 3-23 Features Menu, 802.1q Port Settings tab The 802.1Q Port Settings tab is used for the VLAN configuration of specific ports. Each port can be configured for: A unique Default VLAN ID (VID) Tag-Insert / Tag-Remove functionality on egressing and ingressing frames, and double Tag support VLAN filtering on ingressing frames To Configure VLAN IDs and Tag Remove / Insert per port: 1. Click on the Features icon and select the from the Features menu the 802.1Q Port Settings tab, Assign the Default VID (VLAN ID) for each port (any value between 1 and 4095). 2. To set the tag operation for each port, select [v] the appropriate box. NOTE: Only one of the options (Egr. Tag Remove or Egr. Tag Insert) can be assigned to a port at any one time. The Tag settings are always operational, regardless of the VLAN filtering setting. Table Q VLAN Tag Configuration Selected [ ] Deselected [ ] Ing. Tag Removes 802.3ac tag (or double tag) on tagged Ingressing frames are Page 39 of 87
40 Table Q VLAN Tag Configuration Selected [ ] Deselected [ ] Remove ingressing frames. not modified. Egr. Tag Remove Egr. Tag Insert Egr. Dbl. Tag Sup. VLAN Filtering Removes tag from egressing frames. Adds tag to untagged egressing frames (adds the Default VLAN ID assigned to the port through which the frame entered the switch). Tagged frames are not modified. Double Tag support on Egress. When Egr. Tag Insert is selected, always adds a tag on egress. Tag will be added to both untagged frames and to tagged frames (double tag). Filters frames for the VLAN membership of the marked port. Frames are transmitted unmodified. Frames are transmitted unmodified. No double tag support on egress. Frames are received unfiltered. NOTES: VLAN filtering operates on the port s incoming and outgoing frames. A port whose VLAN Filtering is enabled will only forward a frame if it is a tagged frame of the VLAN that the port is a member of. A non-vlan frame will be treated as if having the default VID of its ingress port. To avoid VLAN lockout, it is necessary to configure the VLAN membership (via the 802.1Q VLANs tab) before enabling the VLAN filtering. Frames without VLAN Tag or frames which their Tags are removed on Ingress (Ing. Tag Remove) will be filtered (if the VLAN filtering is enabled on both the switch and the specific port) according to the Default VLAN ID (Default VID) assigned to the originating port Port Based VLAN Figure 3-24 Features Menu, Port Based VLAN tab Port Based VLAN is a simple way to designate a specific VLAN association for each port by itself. This Page 40 of 87
41 option is useful in managing sensitive ports that should not be accessible to other ports, or limited ports that should only be able to access the uplink port. The default setting for the Port Based VLAN allows every port access to all other ports basically, normal switch operation. To modify the Port Based VLAN, 1. Click on the Features icon and select from the Features menus. Port Based VLAN and VLAN Mode tabs. 2. In the VLAN Mode tab, select Port Based VLAN Enabled. 3. In the Port Based VLAN tab, go to the port line you wish to modify (Horizontal lines) and uncheck ports that the modified port should not be able to access. 4. Click Apply, and on the confirmation box click Yes. NOTE: Port Based VLAN cannot be active when 802.1q VLANs are active. To select one or the other, go to the VLAN Mode tab Transparent VID Figure 3-25 Features Menu, Transparent VID tab Transparent VID is a further enhancement to VLAN tag configuration. This function is useful to support an application or device that does not accept tagged frames on an otherwise tagged network. The Transparent VID function defines a unique "transparent" VID to selected trunk port(s). If the Egress Tag Insert is selected on those trunk port(s) and Transparent VID is enabled, a tag will not be added to frames bearing the "transparent" VID when egressing. Those frames will be transmitted untagged while all other frames, bearing other VIDs, will be transmitted tagged. This is equivalent to the native VLAN in Cisco terminology. To Configure Transparent VID: 1. Click on the Features icon and select the from the Features menu the Transparent VID tab. 2. Check Enable to activate the Transparent VID feature. 3. Enter the VID and check the appropriate ports. 4. When finished, Click Apply, and on the confirmation box, click Yes Rapid Spanning Tree Protocol (RSTP) Configuration The manageable Mosaic switch supports the Spanning Tree Protocol (IEEE 802.1D) and the Rapid Spanning Tree Protocol (IEEE 802.1w), which prevent loops in the network while enabling path Page 41 of 87
42 redundancy links. The Spanning Tree Protocol (STP) is a link layer network protocol that ensures a loop-free topology for any bridged LAN. Spanning tree allows a network design to include spare (redundant) links to provide automatic backup paths if an active link fails, without the danger of bridge loops, or the need for manual enabling/disabling of these backup links. NOTE: Bridge loops must be avoided because they result in flooding the network. The STP creates a meshed network of connected Layer 2 bridges (typically Ethernet switches), and disables those links that are not part of the tree, leaving a single active path between any two network nodes. The IEEE 802.1w introduced an evolution of the STP, known as Rapid Spanning Tree Protocol (RSTP). RSTP provides faster spanning tree convergence after a topology change. Standard IEEE 802.1D now incorporates RSTP, making STP obsolete. While STP can take between 30 and 50 seconds to respond to a topology change, RSTP typically responds to changes within 3*Hello, where the default is less than 10 seconds. The RSTP provides rapid convergence of the spanning tree by assigning port roles. Using handshake and based on the IEEE 802.1D STP, it selects the switch with the highest switch priority (lowest numerical priority value) as the root switch and a root port - this port provides the best path (lowest cost) when the switch forwards packets to the root switch. The manageable Mosaic switch operates in RSTP with backwards compatibility to STP. It will change to STP after receiving STP BPDUs. Note: In the manageable Mosaic switch, the Spanning Tree disregards VLAN configuration, i.e. loops are detected even between ports configured to different VLANs. To configure RSTP Click on the Features icon and select from the Features menu the RSTP Settings tab. The following screen is displayed: Figure 3-26 RSTP Settings tab Note: The tab displays the factory default RSTP settings. Update the following fields as required: Priority: This is the user assigned switch priority that is used by the RSTP switches in Page 42 of 87
43 the network for selecting the root switch. Enter a value from , in increments of Bridge Max. Age: Determines the amount of time protocol information received on a port is stored by the switch. Enter a value between 2 60 seconds. Bridge Hello Time: Determines how often the switch broadcasts hello messages to other network devices. Enter a value from between 2 60 seconds. Bridge Fwd. Delay: Determines how long each of the listening and learning states last before the port begins forwarding. Enter a value between 2 60 seconds. NOTE: According to the Spanning Tree IEEE802.1D protocol; a Bridge shall enforce the following relationships: 2 X (Bridge_Forward_Delay seconds) >= Bridge_Max_Age Bridge_Max_age >= 2 X(Bridge_Hello_Time +1.0 seconds) After network stabilization the following read only fields will be updated according to the RSTP results: Designated Root: The details (priority and MAC address) of network device that was selected as the root switch. Root Cost: The sum of hop costs toward the root switch. Root Port: The port through which traffic is forwarded towards the root switch. Expand the RSTP Ports Configuration tab (see, set up the following parameters for each port configured in the network topology: Figure 3-27 RSTP Ports Configuration tab Priority: Priority of the port for the spanning tree algorithm. A lower number is regarded as higher priority. Enter a value between , in increments of 16. Enable: Activate or deactivate (Check/No Check) the port to participate in the spanning tree algorithm. Path Cost: Cost of the port for spanning tree algorithm. The lower number is regarded as a better path. Enter a value between 1 268,435,455. After network stabilization the following read only fields are updated according to the RSTP results: State: The current state of the port as a spanning tree member port. Page 43 of 87
44 Oper Edge: Detects whether the port is an edge port (usually connected to a user host/device) or a network port. A network port will receive BPDU frames whereas an edge port will never receive BPDU frames. Click Apply to activate and save the RSTP settings. Note: When Apply is clicked, the system checks the validity of the parameters. An error window, indicating the correct range, appears in case of incorrect parameter settings IGMP To configure IGMP Click on the Features icon and select the from the Features menu the IGMP Snooping Configuration tab. Configure Status (Enable, Disable), Join and leave Messages Click IGMP Snooping Discovered Configuration to get a table view of the IGMP Snooping discovered Ports Configuration Page 44 of 87
45 4 Remote Device Configuration Before configuring an IP entity on the network, and in order to remotely manage and monitor a device, the IP parameters of the device must be defined. In manageable Mosaic switch this is done by running an application on the PC. The application performs auto discovery of all connected devices. In manageable Mosaic switch, the RS232 CLI (command-line interface) serial cable is required to perform remote IP configuration of local devices. The manageable Mosaic switch is supplied without the CLI serial cable. To remotely manage and monitor a device without the CLI serial cable, the Legrand LCS 2 - FTTO Init application must be installed. To configure the IP parameters, the user must first connect the CLI cable, run the Terminal Emulation application to log on to the manageable Mosaic switch unit, and then configure the network IP parameters. 4.1 Configuration via the Terminal Emulation Application NOTE: This section describes the procedure for running the HyperTerminal emulation application. The procedure may vary for other applications. To set up the HyperTerminal application: 1. Start HyperTerminal application used by PC. (Legrand recommends Tara Term) 2. Connect the CLI serial cable acquired from Legrand between the switch CLI port and a serial port on your computer. (if used Serial to USB adaptor, connect cable to one of the computer USB ports) 3. From computer, Device manager, identify the port (COM) used for the CLI cable and confirm the setting of port to follow the setting as in next figure. Figure 4-1 COM Properties Window 4. Reset the power on the manageable Mosaic switch switch by pressing the reset push button (, or carefully disconnect and reconnect the power cable if it was already connected). The current definitions will appear as shown in the boot sequence below. Page 45 of 87
46 Figure 4-2 Hyper Terminal Boot Sequence NOTE: The actual appearance or values may differ from version to version or per system configuration Configuring the IP and Community Parameters The manageable Mosaic switch unit is shipped with the following defaults: DHCP Disabled IP Address Netmask Default Gateway TFTP Server Address Get Community Public Set Community Private Default password mypass (case sensitive; Telnet password). 1. Enter a Terminal Emulation application as described in previous section. Page 46 of 87
47 2. To change password, one need to halt the boot sequence Press any key within the five second countdown period, in order to enter the configuration mode. The password prompt appears. NOTE: If you do not press any key within the five second count down, the firmware loading will continue and the management agent will start running. In this case, you will need to start the process again by restart of the manageable Mosaic switch unit. 3. Enter the default password mypass (case sensitive). The prompt Change Password appears, enabling you to change the default password. Please enter CLI password - mypass Change password? [Y/N] Y 4. Change the password (recommended) by entering Y. 5. Enter a new password (up-to 12 alphanumeric characters). It is recommended to use a combination of upper and lower case characters. NOTE: You will be prompted if the password is not within the required format. This password is also used for Telnet access. 6. Next, the prompt Please enter IP parameters appears, enabling you to configure the following IP parameters for the SNMP agent: DHCP, IP Address, Netmask and Default Gateway. NOTE: Current settings are displayed between squared brackets [ ]. Pressing enter keeps the current setting and move on to the next line. In order to modify a line, enter the appropriate information. At the end of this configuration session, the user can choose to continue by typing C, or to return in order to modify one or more of the previous entries by typing M. Please enter IP parameters IP address [ ] - Netmask [ ] - Default gateway [ ] - Modify the above or continue? [M/C] - C 7. The next configuration session is for boot parameters. Page 47 of 87
48 Please enter new boot parameters SNMP get community [public] - SNMP set community [private] - TFTP server address [ ] - FTP user [HighPerf] - FTP password [highperf] - TFTP filename [wp68x_ bin] Boot operation [1: Download, 2: Run] 2 Modify the above or continue? [M/C] - c You will be prompted to change the SNMP Community String. The community string is part of any SNMP packet. The SNMP agent does not respond to SNMP packets whose community string does not match its internal community string. The community string is an alphanumeric string of up to 15 alphanumeric characters. SNMP defines different community strings for Get and Set commands. The factory default community settings of the device are: SNMP Get community - public SNMP Set community - private The TFTP prompt appears, enabling to change the TFTP parameters which refer to firmware upgrades. This is usually necessary at this stage. Consequently, press enter at each of the following prompts. Refer to Section 7.2 for complete instructions on local and remote firmware upgrade. Three Boot operation possibilities are available. Option 1 refers to firmware upgrades using TFTP as described in Section 7. Option 2 allows restart of the unit with the new parameters. The next step of this final configuration session continues by typing C, or to return in order to modify one or more of the previous entries by typing M. The unit restarts with the updated parameters displayed on the screen as follows: Page 48 of 87
49 Boot operation [1: Download, 2: Run] - 2 Modify the above or continue? [M/C] - c (Updated parameters appear here) Storing updated boot record... done Initializing bootloader telnet interface Copy image to RAM done XXX Firmware V (Build Date and time) Management agent running... Validating firmware licensing options: MAC address (MAC address) Features string (add-on features letter(s), such as X for 802.1X)) License key (License key) Validating key...pass For restoring factory defaults use RSTFCT (case sensitive) For setting new license key use setlic For network connectivity test use ping In addition to the updated parameters, the MAC address of the management agent also appears, as well as the special features and the licensing key for such features, if relevant. Also displayed are three additional commands: RSTFCT, setlic and ping. These commands, described below, are available any time via the CLI connection The RSTFCT Command The RSTFCT command (reset to factory defaults) is used to restore factory defaults. The command is case sensitive. 1. Type RSTFCT to reset values to their factory defaults then press enter. 2. The unit restarts according to factory default values The SETLIC Command The setlic command is used to activate special features by entering the letter(s) which represents each feature as well as the appropriate license key. Each feature is identified by a specific letter, and the Page 49 of 87
50 license is acquired according to the feature string (one license is issued for a string representing individual or multiple features). 1. Type setlic then press enter. 2. When prompted to enter the features string, type the upper case letter(s) representing the feature string. For example, X (case sensitive) which is for the 802.1X protocol and then press enter. 3. When prompted, type the License key you received from Legrand then press enter. 4. When prompted to Modify or Continue, type C to continue. 5. The system will inform you that new license information is being stored. The manageable Mosaic switch device must be restarted to activate the special feature. The management application (WizView or Web management) must also be re-started in order to view and manage the special feature The PING Command When connecting the manageable Mosaic switch to the network, or whenever network connectivity needs to be tested, the integrated ping command can be used. The network connectivity is tested by typing ping xxx.xxx.xxx.xxx where xxx.xxx.xxx.xxx is the IP address of the server / device on the network with which connectivity is verified. It is recommended to run this test at the end of the installation process when the unit is initially connected to the network. Page 50 of 87
51 4.2 LAN Configuration via the LCS 2 - FTTO Init Application Running the LCS 2 - FTTO Init application N order to run the LCS 2 - FTTO Init application, double click the program icon to invoke the application. The following screen is displayed. Figure 4-3 LCS 2 - FTTO Init Discovery screen Click Start to begin the discovery process. When the process is complete, the list of discovered devices is displayed. Figure 4-4 LCS 2 - FTTO Init Discovery screen - Discovered Devices Select the device you wish to configure remotely. The LCS 2 - FTTO Init Password prompt dialog is displayed. Figure 4-5 LCS 2 - FTTO Init Password prompt dialog Page 51 of 87
52 Type in the default Legrand password: mypass and click OK. The LCS 2 - FTTO Init screen is displayed. Figure 4-6 LCS 2 - FTTO Init Main Screen Configuring the IP and Community Parameters The manageable Mosaic switch unit is shipped with the following defaults, which can all be changed: IP Address Default Gateway Subnetmask DHCP Disabled Get Community Public Set Community Private FTP Server Address Default password mypass (The mypass password is case sensitive and applies to all configuration tools LCS 2 - FTTO Init and Telnet.) Changing the Password Change the password used to access a device via LCS 2 - FTTO Init as follows: 1. On the LCS 2 - FTTO Init screen, click the File menu, and choose Change Password. The following dialog tab is displayed. Page 52 of 87
53 Figure 4-7 Changing the LCS 2 - FTTO Init password 2. In the Password field, enter your current password. (The default password is mypass ). 3. In the New Password and Verify Password fields, enter your new password. 4.3 Default Settings of the manageable Mosaic switch Restoring manageable Mosaic switch Default Settings User may restore default parameters at any time through the following ways: From Telnet (see Section 8) by typing the Restore Factory command. From the Web management. (Click the System icon and select the Factory Defaults. Press the Restore bar). Using the LCS 2 - FTTO Init application, click the Commands menu and choose Reset. Using the CLI connection, type the RSTFCT command (case sensitive). The following parameters that may be configured through the CLI won t be affected by the restore factory default commands: CLI password, IP address, Netmask, Default gateway, SNMP get community, SNMP set community TFTP server address, TFTP filename, Features string, License key. (These parameters may be configured by CLI and remote management) Changing manageable Mosaic switch Factory Default Settings The manageable Mosaic switch factory default settings provide the basic switch configuration of port status and management, in which all ports and management are open and accessible. The factory default settings may be changed only by technicians (user level: Technician), in cases higher level of Page 53 of 87
54 security is required. The factory default settings can be changed to assign a specific VLAN for management access, and/or to close all user ports as the factory default, if you choose to enable VLAN secured access through the uplink port option. You can change the factory defaults via the Embedded web interface application, or via the LCS 2 - FTTO Init application. Change factory defaults via Embedded web interface as follows: 1. Log in to the Embedded web interface application as Technician. 2. From the Embedded web interface application menu, click System Config., and then click the Configuration tab on the System Configuration screen. Figure 4-8 Changing Factory Defaults via Embedded web interface Port Status may be changed from All Open to Uplink Only. If you choose Uplink Only, the switch and itʼs management will only be accessible from the uplink port. Mgmt. VLAN is used to disable/enable VLAN filtering to management access (Default is Disabled), and Mgmt. VID is used to select the management VLAN ID. 3. The new factory defaults will be activated after the next Restore Factory Default command Restoring manageable Mosaic switch Factory Default Page 54 of 87
55 Settings 1. Log in to the LCS 2 - FTTO Init application. 2. From the LCS 2 - FTTO Init application menu, click Commands, and choose Restore Factory Defaults. The following prompt is displayed. Figure 4-9 Restoring Factory Defaults via Embedded web interface 3. Click Yes to restore the deviceʼs factory defaults Configuring Active Management Interfaces Factory defaults configure all three management interfaces (SNMP, Web and Telnet) to be active. This configuration can be changed for the device to be only managed by one or a combination of two management interfaces To configure the management interfaces proceed as follows: 1. From the Embedded web interface main screen, click System Config. The System Configuration window appears. 2. Click the Config tab of the System Configuration window. The following screen is displayed. Page 55 of 87
56 Figure 4-10 Changing Management Interfaces 3. Under Management Interfaces, make another selection from the Services field drop down list. Figure 4-11 Changing Management Interfaces-Services Page 56 of 87
57 5 Device Security 5.1 Securing Management Access There are three ways to remotely manage the manageable Mosaic switch device: from the Embedded web interface application, via any Web browser or Telnet. The manageable Mosaic switch provides various advanced methods for securing the remote management access. The management access security features, provided for the different management applications, are listed in the table, below, Table 5-1 Remote Management Access Security Methods of Security Management Embedded Web Telnet web Management interface Application Community Strings (SNMP) Yes Yes -- Get Community and Set Community strings. User Access Levels Three password protected user access levels. Management Access List Yes Yes Yes (Single level) Yes Yes Yes Restricts access only to managers whose IP address is defined on this list (white list). Management Access Path Yes Yes Yes Restricts access through either the user or backbone ports. VLAN Secured Management Yes Yes Yes Assigns specific VLAN for management in order to isolate and secure management traffic and avoid management flooding by irrelevant traffic. Web Management User's Authentication -- Yes -- Authentication of Web management access via a Radius server (see Section Page 57 of 87
58 5.1.7) Community String / Passwords The community string is part of the SNMP packet. The SNMP agent will not respond to SNMP packets whose community string does not match its internal community string. The community string is an alphanumeric string of up to 15 alphanumeric characters. SNMP defines different community strings for Get and Set commands. The factory default community settings of the device are: SNMP Get community public SNMP Set community private These community strings may be modified through the CLI or via the Telnet commands: set get community and set set community (see Section 8) User Access Levels The manageable Mosaic switch defines three user access levels: Guest, Administrator and Technician. For details, see Section and Section Management Access List The management access list restricts management access only to managers whose IP address is listed in the device Access List. Up to eight entries can be defined. When the access list is enabled, the device may be reached only by remote manager(s) whose IP address is listed in the access list. When the access list is disabled, the device may be reached from any IP address. NOTES The access list may also be managed through Telnet "show/add/delete acl entry" command (see Section 8). The access list security cannot be enabled unless the IP address of the active manager exists on the list. The IP address of the active manager cannot be deleted as long as the Enable access list is check-marked. To define the Management Access List: 1. From the Embedded web interface main screen, click Management and expand the Access List tab. Page 58 of 87
59 Figure 5-1 Management menu, Access List tab 2. Click Add, type the IP address of the remote managerʼs workstation from which access will be allowed in the new window and click OK. Repeat for each additional IP address to be added (up to eight). 3. Verify that the IP address of the active manager (issuing the command) is on the Access List. 4. From the Enable/Disable list, select Enable. 5. Click Apply and then click Yes in the verification window. To delete an address select the address from the list and click Delete Management Interfaces Factory defaults configure all three management interfaces (SNMP, Web and Telnet) to be active. This configuration can be changed so that the device can only be managed by one or a combination of two management interfaces. To configure the management interfaces proceed as follows: 1. From the Management menu click the Management Interfaces tab to make a selection from the Services field drop down list. 2. Click Apply Page 59 of 87
60 Figure 5-2 Changing Management Interfaces-Services Management Access (Secure NMS) Path The in-band management path can be secured by limiting the remote access through either user ports, backbone ports or all ports. By default, the NMS path is not secured, allowing access from all ports. To change the Secure NMS Path: 1. From the Embedded web interface main screen, click Management and expand the Secure NMS Path tab 2. Select the required option from the Path list. The following options are available User Ports Only access is allowed only through the user ports (ports 1-4). Backbone Port(s) Only access is allowed only through the backbone ports (uplink ports 1-2). All Ports Secure NMS Path option is disabled and access is allowed through all ports. NOTE: MGMT VLAN filtering overrules NMS access path. Figure 5-3 Changing the Secured NMS Path 3. Click Apply Securing Management Access via VLAN Securing management access via VLAN is used to isolate and secure management traffic and avoid management flooding by irrelevant traffic. Page 60 of 87
61 The manageable Mosaic switch enables assigning a dedicated VLAN to the internal management port. Only frames belonging to that specific VLAN, received from ports belonging to the same VLAN membership group, can communicate with the management agent. This type of VLAN configuration provides an additional level of security to the management access. Assuming the switch operates in 802.1Q VLAN (i.e. the "802.1Q VLAN filtering enable" is checked (selected), and the "VLAN filtering" is checked (selected) on all the ports) management access will only be available for the following frames: VLAN frames, with VID=4095, arriving from the uplink port. Non-VLAN frames arriving from the uplink port (only if the default VID of the uplink port is also configured to 4095). If the frame arrives without a VLAN, and the VLAN filtering of this port is selected, the filtering is according to the configured default VID of the port (4095 in our example) Any other frame, whether VLAN (with other VID number) or non-vlan arriving on ports other than the uplink port, will be filtered, and will not be forwarded to the management agent. Response frames, transmitted from the internal management agent to the remote manager, are VLAN frames with VID= Web Management User s Authentication Legrand manageable devices can be configured to seek user level password authentication from a central Radius server, such as from a Freeradius, Winradius or Radiator server, while logging in from a Web browser. The advantage of storing user level passwords in the Radius server is that if / when the Web management passwords are changed, they need be changed only in the Radius server and not in each individual device. Activating the Web management user authentication, via a Radius server, is described in Section Securing Network Access The manageable Mosaic switch provides enhanced network security features by introducing advanced port based network access control. The manageable Mosaic switch supports port based MAC access security as well as 802.1X port based network access security (optional) MAC Access Security - Securing User Access to the Network The MAC access security protects the network from unauthorized "guests" attempting to access the network through the user ports of the device. MAC security takes advantage of the automatic learning and aging time of the access switch to provide MAC level network access security. MAC security operates on active devices, devices that send out frames to the network on a regular basis like any standard PC, notebook or other workstation. It is Page 61 of 87
62 not recommended to use MAC security for a passive device (for instance a printer) since passive devices do not initiate frame transmissions and therefore are not learned automatically by the device. The MAC security feature is configurable only from the administrator and technician levels. MAC security has two operation modes, High Security Level and Low Security Level High Security Level High security allows only one specific MAC address on the port look-up table. If the port learns additional or different MAC addresses, the port will immediately be blocked. The port will re-open automatically only when the permitted device is connected and the aging time has elapsed of all other MAC addresses. High security ensures single device access to the port. For example, the network manager can designate the MAC address of an employee's workstation to a specific port as the only approved address for this port. In this way, the employee's PC has sole use of that port. If another device connects to that port, the port will block all data transmission Low Security Level Low security enables the access of multiple devices to one secured port (or a segment connected to the port via an additional external switch / hub) as long as one of the devices connected to the port bears a specified MAC address. When the designated device is connected to the port, the presence of its specified MAC address on the look-up table of the port opens port access for all the devices on the segment. When that specific MAC address does not exist on the look-up table, the port is blocked to all the devices. An example of this is a researcher who has a number of LAN devices (a PC, a printer, a notebook, testing equipment, etc.) hooked-up to a "local lab segment" connected to the organization's network through manageable Mosaic switch secured access port. The researcher has assigned his notebook as the approved address. When low security is enabled, all the devices on the lab segment cannot access the network unless the researcherʼs notebook is connected to the lab segment. Another example is the company conference room that has a local segment. Visitors may plug into the segment but it will stay isolated from the network unless a company authorized representative is present and connected. NOTE: The Low Security Level blocks data transmission through the port after the aging time of the approved address has elapsed. It is important to keep this in mind when configuring the aging time parameters To Configure MAC Access Security There are two modes of MAC security: MAC Access Security is locally authenticated according to the approved MAC The Approved MAC is authenticated by the Radius server before continuing with the MAC Access Security process. The MAC security mode is selected only through the Telnet application. See Section 8.5. Set a locally approved MAC address as follows: Page 62 of 87
63 1. In the Embedded web interface main screen, click on the required Port icon. The Port View window appears. Expand the MAC Security tab. Figure 5-4 The Port View Window MAC Security tab MAC Security Configuration Fields: MAC Address 1-3 list displays the MAC address entries belonging to that port in the look-up table. Approved MAC field displays the specific MAC address to be secured (the MAC address according to which the MAC security algorithm works). Mode field displays the MAC security operation mode (disabled, low security or high security). Status field displays the port security status (disable, port forwarding, or port blocked). When disabled appears in the Status field, this means that the MAC security is disabled. When port forwarding or port blocked appears in the Status field, this means that the MAC security is enabled and that specific port is either forwarding or blocked in accordance to the MAC security algorithms. NOTE: Port Monitoring, MAC security and 802.1X cannot be active at the same time. 2. In the Approved MAC list select the MAC address to be designated as the approved MAC address. 3. Open the Mode list and set the mode according to the following parameter descriptions: Disable MAC security is not enabled. Low Security Level The port is open (forwards data) for all devices as long as the approved MAC address exists on the port's look-up table. When the designated device is disconnected and its MAC address is removed from the port table, the port blocks data communication to all devices. High Security Level Only the designated approved MAC address can use the port (i.e., only the approved MAC address exists on the portʼs look-up table). If the port receives frames from another device (other addresses in the look-up table), then the port blocks all data transmission, even for the approved address. NOTE: When a port is blocked through MAC Security it is detected as a major event and an appropriate trap is sent to the authorized SNMP managers. Page 63 of 87
64 X Port Based Network Access Security General Description Three components, illustrated in Figure 5-5, are required to create an access authentication scheme based on 802.1X standards: Authenticator Authentication Server X Supplicant clients Figure X Access Authentication Scheme The 802.1X Supplicant workstation is the device that needs authentication in order to access the network. This device must have operational 802.1X Supplicant service. Consult the network administrator to assure that the 802.1X Supplicant is installed and properly configured on the workstation(s). Upon connecting the workstation to an 802.1X enabled port in the manageable Mosaic switch, the Local Area Connection log-in window should appear to enable the user to log-in to the network. Devices which do not have 802.1X Supplicant service will not be able to access the network. The Authenticator (manageable Mosaic switch) is the device performing the X port access securities and controlling access to the network. The Authenticator invokes the 802.1X Supplicant on the workstation and waits to receive the login information from the user. After receiving the login information the Authenticator checks with the Authentication Server and performs the necessary action (block or permit) based on the results received from the Authentication Server. The Authenticator uses RADIUS (Remote Authentication Dial-in User Service) to communicate with the Authentication Server (such as, Freeradius, Winradius or Radiator servers). The Authenticator (manageable Mosaic switch should be configured with the Authentication Server address and shared password in order to enable communication between them. The Authentication Server is a central network device which maintains the login information of permitted users. The Authentication Server validates the username and password information of the client and instructs the Authenticator whether or not to block or permit network access to each specific Page 64 of 87
65 client. Manageable Mosaic switch Installation and User Guide Defining the Radius Server via Telnet 1. From the Windows Start Menu select Run and type Telnet then the IP address of the manageable Mosaic switch device. 2. At the prompt, enter the default password, mypass (case sensitive) or the new Telnet access password you may have defined. NOTE: If you type show radius the Server IP address will be displayed followed by the Shared secret hidden by *** (three asterisks). The factory default for the Server IP address is and the Shared secret is *** (three asterisks). 1. At the prompt, type Set radius server [your radius serverʼs IP address]. 2. At the prompt, type Set radius secret [your shared key password with the Radius Server]. NOTE: You must enter your shared key password since there is no active default password. The Radius server definitions are not maintained in the RSTFCT (restore factory default) command. 3. Type Logoff. NOTE: You can configure manageable Mosaic switch manageable devices to have their Web access passwords authenticated by the Radius server. In order to do this, use the Telnet command set http password radius (see Section 8) Activating the 802.1X Authentication Security Protocol Figure 5-6 Port View Window, 802.1X Tab The 802.1X tab includes the following fields: Mode: Selection box that allows choosing between Enable and Disable. Supplicant Addr.: MAC Address of the device connected to the port. Status: Text description of the current 802.1X status of the port. User Name: Displays the Logon Domain followed by the User Name as entered by the user on the supplicant device connected to the port. Pae State: States the current 802.1X machine status information. Page 65 of 87
66 Backend State: States the current 802.1X machine status information. Restart: Restarts / Refreshes the authentication process on the authenticator and thus also on the supplicant Enabling the 802.1X Authentication Security Protocol Now that the Radius Server has been defined and the 802.1X Security Protocol has been installed and can be managed, the next step is to enable the 802.1X port based network access on the desired port(s). In the Embedded web interface main screen, click the desired Port to access the Port View window. 1. From the Port View window, expand the 802.1X tab. 2. Click the Mode list and select Enable. 3. Click Apply and in the confirmation window click Yes. Repeat this procedure for each required port. The 802.1X Authentication Security Protocol is now enabled on the desired port(s). The management application will show a lock icon on the secured port(s). Port 1 in Figure 5-7 marked with the red lock specifies that the port is already enabled but not yet authorized by the Authentication Server. Once, Authentication Server authorized the port the lock icon will change its color to green. Figure X Access Authentication Enabled icon Secure HTTP Protocol (HTTPS) General Description Hypertext Transfer Protocol Secure (HTTPS) is a combination of the Hypertext Transfer Protocol with the SSL/TLS protocol to provide encryption and to secure identification of the server. HTTPS connections are often used for sensitive transactions in corporate information systems. HTTPS aims to create a secure channel over an insecure network. This ensures reasonable protection from Page 66 of 87
67 eavesdropping and man-in-the-middle attacks, provided that adequate cipher suites are used and that the server certificate is verified and trusted. The trust inherent in HTTPS is based on major certificate authorities that come pre-installed in the Web browser software. This essentially permits a certificate authority (e.g. VeriSign, Microsoft, etc) to determine trusted sources Enabling HTTPS Figure 5-8 HTTPS Enabled icon Page 67 of 87
68 6 Monitoring and Analysis The manageable Mosaic switch provides monitoring and analysis functions on both device and port level: Device level The device stores the last 64 events. The event display can be filtered according to user defined criteria. The system reports three levels of events: notify, minor and major. Major events will have the words Major and the menu title Events marked in red. Events may be acknowledged by an Administrator or Technician level user. Only events occurring on the network ports of the device are recorded. Configuration changes that are initiated by the network manager are not considered events. Events can also be transmitted, as SNMP Traps, to additional managers by adding their IP address to the deviceʼs SNMP Trap Destination list. Port level Monitoring and analysis includes port specific RMON and statistics counters and port monitoring (mirroring) viewing valid data of one port on another user defined port. 6.1 Configuring SNMP Trap Destinations When a system event is detected, the device sends a trap to a list of authorized SNMP managers. The list of managers is configured through the management application. NOTE: The Trap destination list may be configured through Web, Telnet and Embedded web interface. Only Administrator or Technician level are allowed in Embedded web interface to configure te Trap destination table To configure the SNMP Traps destination addresses: 1..From the Embedded web interface main screen, click Management icon tab 2. Select the Trap Destination tab and click Add bar 3. In the IP Address box, enter the destination IP Address to which traps generated by this device will be sent. Click OK. The address will appear in the IP Address list. 4. Repeat for each additional IP Address. Figure 6-1 Management menu, SNMP Traps tab NOTE: To remove a traps destination address, select the address and click Delete. Page 68 of 87
69 6.2 Device Level Event Log Viewing Recorded Events The last 64 events are stored in the device and are available for display at any time through the Event Log window, located at the bottom of the Embedded web interface main screen. The Event list is cleared when turning on or resetting the device. When a management application is continuously managing the device, an unlimited number of events are displayed for the currently managed device. If the management application disconnects from the device and reconnects, only the last 64 events that are stored in the device are uploaded to the Event Log. Only events occurring on the network ports of the device are recorded. Configuration changes that are initiated by the network manager are not considered events. The viewed events may be acknowledged and filtered according to various user defined criteria. The events recorded are: Major Events: Device voltage: changes that exceed the thresholds and return to limits. Internal temperature of the device: changes that exceed the thresholds and return to normal. NOTE: Thresholds levels may be modified by technician level access. Port Locked due to security definitions: when an unauthorized MAC address connects to a MAC Secured port. Minor Events: There are currently no events defined as Minor in the manageable Mosaic switch. Notify Events: Change in Port status: Link up, Link down. System startup To get a full view of the Event Log window user need to click the arrow on its top right corner. Figure 6-2 Event Log window Page 69 of 87
70 Each trap notification consists of: A unique index number Event date and time stamp Event description Event source Severity (notify, minor, major) Acknowledge (yes or no) Event Levels and Color codes: The record is colored according to its severity: Notify (cyan) Minor (yellow) Major (red) To Sort information: From the Event Log window, click any header to sort the information according to the selected header in ascending or descending order. To acknowledge events: From the expanded Event Log window, select the requested event(s) in the table and click the Ack on the bottom right. NOTE: Only Administrator or Technician level users can acknowledge events Event Filter Figure 6-3 Event log with the Event Filter window Events may be filtered according to different parameters and can help the network manager focus on specific events. Page 70 of 87
71 The filter operates according to the following parameters: Dates, Time, Port Number, Severity and Acknowledged / Unacknowledged events. To filter the displayed events: 1. From the Embedded web interface main screen, click the arrow in the Event Log to enlarge displayed data From the Event Log window click Filter. The Events Filter window appears as shown in Figure 6-3 Figure Check the box for each parameter you wish to include in the filter (Date, Severity and/or Source) and define the appropriate filter parameters. NOTE: Unchecked Filters will result in displaying all the events related to that filter. 3. In the Acknowledgement area, select either Acknowledged or Not Acknowledged to filter events according to the parameters as required. NOTE: When neither check box in the acknowledge area is checked, both Acknowledged and Not Acknowledged events are displayed. 4. Click OK to enable the filter definitions. 6.3 Port Level Statistics and RMON Counters RMON (Remote Network Monitoring) provides standard information that can be used to monitor and analyze port traffic from a central site. The manageable Mosaic switch supports RMON RFC 2819 (which supersedes 1757 and 1217) Ethernet statistics group. In addition to RMON information, statistics for RX packets and counters for TX packets can be monitored for each port. Page 71 of 87
72 To display the port RMON information, RX statistics and TX counter: 1. From the Embedded web interface main screen, click the icon of the Port of interest. The Port View window appears. 2. From the Port View window, select the Statistics tab. NOTE: Click Reset to ZERO all counters. Figure 6-4 Port Statistics and Counters 6.4 Port Monitoring The port monitoring feature enables analyzing and recording valid data on a port by mirroring its traffic to another, user allocated (monitoring destination) port. User may monitor the egressing, or both ingressing and egressing data of any port. This feature can be used for network analysis as well as recording port traffic. More than one port can be monitored on a single monitoring destination port. To assure the integrity of the monitored data and since the monitoring port bandwidth is limited to 100Mbps, flow control is automatically activated on the monitored port(s) when the monitored traffic exceeds 100Mbps. To configure port monitoring: 1. From the Embedded web interface main screen, click on the icon Port to be monitored. The Port View window appears. 2. From the Port View window, click Monitor tab. Page 72 of 87
73 Figure 6-5 Port View window, Monitor tab 3. Select the Port Monitoring Mode from the Mode list described in the following table: Table 6-1 Port Monitoring Mode Options Option None Egress Only Description Port monitoring mode not enabled. Only egress frames are copied to the destination port. When the device is reset, the monitoring mode resets to None. Egress & Ingress NV Egress Only Egress and ingress frames are copied to the destination port. When the device is reset, the monitoring mode resets to None. Only egress frames are copied to the destination port. Mode remains on after system reset. NV Egress & Ingress Egress and Ingress frames are copied to the destination port. Mode remains on after system reset. 4. Select the destination port from the Destination list and click Apply. Page 73 of 87
74 7 Updating Firmware Versions 7.1 General The manageable Mosaic switch firmware comprises three elements, each updated separately: Image SNMP Agent software Content Java Applet (Web management interface) Configuration Configuration file The firmware may be updated as follows: Locally (CLI) through a serial connection (Section 7.2) Via the LCS 2 - FTTO Init Remote Device Configuration application for devices supplied without the CLI cable Remotely through the Embedded web interface Remote Firmware Update 7.2 Local (CLI) Firmware Update Update the firmware locally through a serial connection as follows: 1. Launch a terminal emulation application. 2. Connect the CLI serial cable to the manageable Mosaic switch switch. 3. Modify the SNMP Get / Set Community parameters (if necessary). 4. Update the IP address of the TFTP server that will be used to download new TFTP software versions to the device. 5. Update the TFTP filename of the new software version to be downloaded to the device. 6. The prompt Boot operation [1: Download image, 2: Download content, 3: Run] appears, enabling to download a file to the device or to continue. Enter 1: Download image to download / update the SNMP agent of the manageable Mosaic switch file with a.bin extension (for example: w56x_290_01.bin). Enter 2: Download content to download / update the Web management applet of the manageable Mosaic switch file with a.con extension (for example: w5xx_282.con). NOTE: Since each file downloads separately, after downloading one file, repeat steps 5 and 6 in order to download the other file. 7. After downloading / updating the image and content files (this may take a few minutes) the user is prompted to enter new boot parameters. Enter new parameters or press Enter to accept the existing parameters. At the Boot operation prompt, chose 3: Run in order to reboot the system with the updated files. Now the unit restarts operations according to the updated files and parameters. Page 74 of 87
75 7.3 Remote Firmware Update via LCS 2 - FTTO Init 1. Launch the LCS 2 - FTTO Init application. 2. Modify the SNMP Get / Set Community parameters (if necessary). 3. Update the IP address of the TFTP server that will be used to download new TFTP software versions to the device. 4. Update the TFTP filename of the new software version to be downloaded to the device. 5. From the File Command list, select the desired command (Download image or Download content), and monitor the download/upload process in the Process and Status fields. Figure 7-1 LCS 2 - FTTO Init screen, Firmware Update commands Page 75 of 87
76 7.4 Remote Firmware Update via Embedded web interface Figure 7-2 File Operations Window 1. From the Embedded web interface main screen, click on Files. The Files window appears as shown in Figure In the File Server tab update the IP address of the File Server that will be used to download new firmware versions to the device (The specified IP must have a running TFTP server program). 3. In the Operation tab update the file name of the new firmware version to download to the device. 4. Select the desired operation from the Command list. Be sure to match the file type with the command (.bin with Download Image,.con with Download Content). NOTE: In order to perform a download or upload operation, the Command being executed must be colored blue, indicating a changed setting. Clicking apply without changing the Command, even if it was set in advance to your desired setting, will not proceed with the command. 5. While downloading / updating the image and content files (this may take several minutes) the Status field will change depending on the current operation being executed. At the end of the process, that field will update again to announce the successful or failed update. NOTE: Since each file downloads separately, after downloading one file, repeat steps 5 and 6 in order to download another file. Page 76 of 87
77 7.5 LCS 2 - FTTO Bulk Firmware Update LCS 2 - FTTO Bulk is a remote firmware update software that allows updating multiple devices simultaneously, without the need to manually connect to each device. Updating firmware using the LCS 2 - FTTO Bulk software: 1. From the LCS 2 - FTTO Bulk screen, click on the Source tab. Figure 7-3 LCS 2 - FTTO Bulk Source screen 2. In the File Server area, update the server IP address, the username and password used to connect to the server and the maximum number of devices that may connect to the server simultaneously (Max Parallel Sessions). 3. In the Download Commands area, check the types of files to be downloaded to the devices (upload not available through LCS 2 - FTTO Bulk) and list the file names to be downloaded. 4. If a reset operation is required for each device, check the Reset checkbox to automatically reset each device after a successful download. 5. Click the Targets tab. Page 77 of 87
78 Figure 7-4 LCS 2 - FTTO Bulk Targets screen 6. In the Auto Discovery area, enter a Start IP and End IP. The devices to be updated must be in that IP range (For example, to update to update three devices ending in 151, 152 and 153, set the Start IP as 151 and End IP as 153). 7. User need to make sure the GET Community and SET community fields match the ones used by the user devices (The default GET Community is "public" and the default SET Community is "private"). 8. In the Targets area, select all the devices to be updated from the list. Use shift click and ctrl click to select multiple devices. 9. Click on the Schedule tab Figure 7-5 LCS 2 - FTTO Bulk Schedule screen 10. In the Start Time area select immediately to begin the update process as soon as possible, or select Delayed and set a date and time to delay the update until that time. 11. In the End Time area select as necessary to allow the update process to take as long as needed to complete, or select Limited and set a date and time to stop the abort the update process if it continues past that time. 12. Click the Status tab. Page 78 of 87
79 Figure 7-6 LCS 2 - FTTO Bulk Status screen 13. To begin the update process (or wait until the Delay time has been reached), click Start. 14. The Progress area displays information regarding which device is being updated at the moment, update status, update progress, time at which the update started, and an estimated time at which the specific update will complete. 15. When the update process is complete, if Reset is selected, each device will restart itself automatically. 7.6 Firmware Licensing (in order to activate optional features) Special add-on features can be purchased separately from Legrand. To activate the feature(s) you need to acquire an activation key from Legrand and install it on the device through the Firmware licensing tab. Each add-on feature is represented by a single letter. Multiple features can operate simultaneously. When a firmware license key code is assigned by Legrand, it will be a single code that covers all the add-on features (existing ones as well as new features being added). When the firmware license for a specialized feature is purchased, the feature is activated by inputting the license key code. In order to generate the license key, the Legrand representative will require the MAC address of the device, as well as previously purchased add-on features (if any). The MAC address of the device is listed in the Inventory tab of the System View window. Page 79 of 87
80 Figure 7-7 System Configuration window, General tab 1. From the Embedded web interface main screen, click System. The System View window appears. 2. From the System View window Inventory tab find the MAC Address of your device. NOTE: Each feature is represented by a single letter which is case sensitive. 3. Supply Legrand Representative with the MAC Address exactly as it appears in the Inventory tab and Feature(s) already installed on device, as well as the special add-on feature(s), to be purchased. 4. Legrand Representative will supply with the feature letter(s) and a license key code which activates the old feature(s) (if any) plus the new feature(s) being purchased Activating the Special Add-on Feature(s) License Key After receiving the feature letter(s) and licensing key from Legrand Representative (as explained in the previous section) activate the feature(s) via the Embedded web interface or Web management application as explained below: 1. Login to the Embedded web interface or Web management application as a Technician or Admin. 2. From the Embedded web interface main screen, click Management. The Management window appears. 3. From the Management window, License tab, Click on the Features field and type the letter(s) for each licensed feature as given by Legrand representative. NOTE: The letters are case sensitive and should be entered as a string without any intervening spaces or punctuation. 4. Click on the Key field and enter the license key exactly as received it from Legrand Representative (it is recommended to cut-and-paste the license key to avoid font and case problems) then click Apply. Figure 7-8 Firmware License Tab Both the manageable Mosaic switch device and the management application (Embedded web interface or Web management) must be restarted to activate and manage the special add-on feature(s). Page 80 of 87
81 Note: it is recommended to confirm that the new add-on feature(s) have been properly activated, by referring to new tabs relevant to the new features through the management applications. (Embedded web interface and Web management, following the restart step) If the validation key indicates fail, then re-check the feature string and license key and re-start the key activation process. If the validation key still does not pass, please contact the Legrand Representative. Page 81 of 87
82 8 Telnet 8.1 General Telnet enables remote management of a single IS-2 unit as well as remote configuration of any number of units by running Telnet script files created for that purpose. 8.2 Run Telnet 1. From the PC Start menu, type Run Telnet followed by a space and then the IP address of the target device (exact syntax according to the operating system). or From a telnet client application, connect using telnet protocol to the IP address of the target device (Note: when using PuTTY, the password can be rejected even if entered correctly. In that case, please make sure to make the following change in PuTTY configuration Ë Terminal : Local Echo: Off and Local line editing Off). 2. At the prompt, enter the current password (mypass is the factory default); the password is case sensitive. If the password is rejected, please see the specific note for PuTTY in 6.2, 1). The device prompt, ʻ> appears. The device is ready to receive Telnet commands (see Figure 8-1). Note: The Telnet password can only be changed through the local CLI (serial) connection Invoking Telnet Help To view the list of available commands, type? or help and press Enter. To invoke help on a specific command, type the command, followed by a space and? Figure 8-1 illustrates the list of available Telnet commands. Figure 8-2 illustrates an example of help on specific command Page 82 of 87
83 Figure 8-1 Telnet Commands IS 2> set port? Usage: set port port_num on off hdx fdx an man set port port_num flowcontrol on off set port port_num egtagins egtagrem ingtagrem on off set port port_num vlanfilter egdoubletag on off set port port_num name new_name set port port_num vid default_vid Examples: set port 2 fdx - change port 2 duplex mode to full-duplex set port 1 egtagrem on - enable VLAN tag removal on port 1 egress set port 2 egdoubletag on - enable double tagging on port 2 egress set port 4 name Greg_laptop - change port 4 name to Greg_laptop set port 3 vid change default VID of port 3 to 1160 Figure 8-2 Telnet Help on specific command 8.3 Selecting the static IP address of the device The static IP address used to manage the device cannot be updated using the web interface. In order to perform this configuration change, it is necessary to connect to the device using telnet. For more information about how to connect to the CLI using telnet, please refer to "6.2 Run Telnet" Once connected to the CLI, you can select the IP parameters of the device by using the following command: set ip params <ip_address> <netmask> <default_gw> Once the configuration has been changed, it will be effective after the next reboot Page 83 of 87
84 8.4 Changing User Level Passwords via Telnet 1. From the Start menu, type Run Telnet followed by a space then type the IP address of the target device (exact syntax according to the operating system). 2. At the prompt, enter the current password (mypass is the factory default); the password is case sensitive. The device prompt, > will appear. The device is ready to receive Telnet commands (see Figure 8-1). 3. Type the command set http password followed by a space and any of the user level access words to change (tech, admin, or guest) and then followed by another space and the new password to assign to that user level, and then press enter. A user level password has now been changed. Changing passwords for one user level does not affect the other user level passwords. For example, changing the password tech to tech1 will use the following command: set http password tech tech1 NOTE: You can type show http password followed by a space and a question mark (?) in order to see what the current user level passwords are. For security reasons, the Telnet session will automatically terminate if there is no Telnet activity for approximately 60 seconds Defining the Radius Server via Telnet 1. From the Start menu, type Run Telnet and click OK. At the Telnet prompt, connect to the target device by typing its IP address (exact syntax according to the operating system). 2. At the prompt, enter the current password (mypass is the factory default); the password is case sensitive. The device prompt, > will appear. The device is ready to receive Telnet commands. 3. Type the command set http password followed by the word radius. The response User authentication changed to Radius server interface will appear. Proceed with the following Telnet commands, as required: To display and verify the http password status you can type show http password. Using the show radius command, verify that the Radius server is properly configured (see Section ). On the Radius server verify that the correct Radius secret is defined and that passwords are assigned to the three user access levels. For security reasons, the Telnet session will automatically terminate if there is no Telnet activity for approximately 60 seconds. To resume the Telnet session you must re-connect and log in again. Page 84 of 87
85 To redirect a Legrand manageable device to check management access passwords locally rather than via the Radius server: Type the Telnet command set http password followed by any of the user level access words (tech, admin, or guest) and then the new password (****) you want to assign to that user level. This will change the password for that particular user level, as well as restore the last passwords assigned to the other two user levels (see Section 0). 8.5 Changing MAC Security via Telnet The following Telnet commands are used to set MAC security parameters: set http password radius The login password is determined by Radius server settings set http password radius mac The Radius server checks that the approved local MAC address is listed on the Radius Server Use the following Telnet commands to return to the default settings: set http password Technician tech set http password Admin admin Page 85 of 87
86 Index 802.1Q VLAN...36 Membership Port Configuration Setup X...61, 64 66, Access List...58 Address Migration...37 Aging Time...61, 62 Authentication Server...64, 66 Auto-Negotiation...20 Boot Sequence...46 Default Change... 53, 55 Parameters... 46, 52 Event Filter...70 Event Log HiView/B Main Screen...28 Color Indications HTTPS Protocol...66 IEEE 802.1d Standard...8 Internet Protocol (IP) Address...45 Learning Time...61 LEDs...28 MAC Access Security , Configuration High Security Level Low Security Level Management Remote Management Options...12 Management Access List Management Access Path Secure NMS Path...60 Monitoring and Analysis Passwords Community String...46, 52, 58, 74, 75 User Name...14 Platforms Port Port Monitoring...72 Port Name...18 RMON...68, 71 Statistics...71 Power over Ethernet (PoE) QOS Rate Limit...27 Radius Server... 15, 16, 61, 65, 84 Rate Limit Remote Software Reset RMON... 68, 71 SNMP Trap Software Update Remote...74, 75, 76, 77 Spanning Tree Telnet VLAN VLAN Secured NMS...60 Before configuring your device, please download the latest firmware from the following website and update your device with this firmware. Warning: for Telnet configuration please read chapter 8 Telnet before connecting. Page 86 of 87
87 Page 87 of 87
Management Software. Web Browser User s Guide AT-S106. For the AT-GS950/48 Gigabit Ethernet Smart Switch. Version 1.0.0. 613-001339 Rev.
Management Software AT-S106 Web Browser User s Guide For the AT-GS950/48 Gigabit Ethernet Smart Switch Version 1.0.0 613-001339 Rev. A Copyright 2010 Allied Telesis, Inc. All rights reserved. No part of
Management Software. User s Guide AT-S88. For the AT-FS750/24POE Fast Ethernet Smart Switch. Version 1.0. 613-000555 Rev. B
Management Software AT-S88 User s Guide For the AT-FS750/24POE Fast Ethernet Smart Switch Version 1.0 613-000555 Rev. B Copyright 2007 Allied Telesis, Inc. All rights reserved. No part of this publication
16-PORT POWER OVER ETHERNET WEB SMART SWITCH
16-PORT POWER OVER ETHERNET WEB SMART SWITCH User s Manual (DN-95312) - 0 - Content Web Smart Switch Configure login ---------------------------------- 2 Administrator Authentication Configuration ---------------------------------------------
4 Ports + 3 SFP Gigabit Smart Switch Use Manual. Ver.A0
4 Ports + 3 SFP Gigabit Smart Switch Use Manual Ver.A0 Chapter 1 Product Specification 1.1 Product Characteristics Complies with IEEE802.3,IEEE802.3u,IEEE802.3ab standards; 4 10/100/1000Mbps Auto-Negotiation
8-Port Gigabit managed POE Switch. User s Manual. Version: 2.3
8-Port Gigabit managed POE Switch User s Manual Version: 2.3 September 9, 2007 1 TABLE OF CONTENT 1.0 INTRODUCTION... 3 1.1 MAIN FEATURES... 3 1.2 START TO MANAGE THIS SWITCH... 5 2.0 WEB MANAGEMENT...
Management Software. User s Guide AT-S84. For the AT-9000/24 Layer 2 Gigabit Ethernet Switch. Version 1.1. 613-000368 Rev. B
Management Software AT-S84 User s Guide For the AT-9000/24 Layer 2 Gigabit Ethernet Switch Version 1.1 613-000368 Rev. B Copyright 2006 Allied Telesyn, Inc. All rights reserved. No part of this publication
MICROSENS. Installation Switch with PoE (5x10/100Base-TX) and fiber uplink (1x100Base-FX) General. Features
Installation Switch with PoE (5x10/100Base-TX) and fiber uplink (1x100Base-FX) MICROSENS General The MICROSENS Installation Switch enables the connection of 5 end devices via twisted pair cable which also
ALL8894WMP. User s Manual. 8-Port 10/100/1000Mbps with 4-port PoE. Web Management Switch
ALL8894WMP 8-Port 10/100/1000Mbps with 4-port PoE Web Management Switch User s Manual Content Content I Introduction..3 Product Overview.3 Web Management Feature.3 Specification..4 Mechanical...4 Performance...5
How To Install An At-S100 (Geo) On A Network Card (Geoswitch)
AT-S100 Version 1.0.3 Patch 1 Management Software for the AT-9000/28 Managed Layer 2 GE ecoswitch and AT-9000/28SP Managed Layer 2 GE ecoswitch Software Release Notes Please read this document before you
AT-GS950/8. AT-GS950/8 Web Users Guide AT-S107 [1.00.043] Gigabit Ethernet Smart Switch. 613-001484 Rev A
AT-GS950/8 Gigabit Ethernet Smart Switch AT-GS950/8 Web Users Guide AT-S107 [1.00.043] 613-001484 Rev A Copyright 2011 Allied Telesis, Inc. All rights reserved. No part of this publication may be reproduced
SHEET. Skorpion Managed Ethernet Switch Series. EISK8M Series
EISK8M Series d a t a SHEET Skorpion Managed Ethernet Switch Series The EISK8M Series offers a compact rugged managed 10/100 Mbps Ethernet switch with a choice of eight copper ports or a mix of six copper
24 Port Gigabit Ethernet Web Smart Switch. Users Manual
24 Port Gigabit Ethernet Web Smart Switch Users Manual Content Web Smart Switch Configure login -------------------------------- 2 Configuration System Configuration ---------------------------------------------------
AT-S60 Version 1.1.4 Management Software for the AT-8400 Series Switch. Software Release Notes
AT-S60 Version 1.1.4 Management Software for the AT-8400 Series Switch Supported Platforms Software Release Notes Please read this document before you begin to use the AT-S60 management software. The AT-S60
WSG24POE Switch. User Manual
WSG24POE Switch User Manual Version: 01/01/2011 Introduction! 4 Product Overview! 4 Specifications! 5 Package Contents! 5 Hardware Description! 6 Physical Dimensions/ Weight! 6 Front Panel! 6 LED Indicators!
ALLNET ALL-SG8926PM Layer 2 FULL Management 24 Port Giga PoE Current Sharing Switch IEEE802.3at/af
ALLNET ALL-SG8926PM Layer 2 FULL Management 24 Port Giga PoE Current Sharing Switch IEEE802.3at/af 24-Port Giga PoE Current Sharing 500W PoE Budget IPv6 and IPv4 Dual Protocol SNMP v1/v2c/v3 SSH version
Easy Smart Configuration Utility
Easy Smart Configuration Utility REV1.1.0 1910010977 CONTENTS Chapter 1 About this Guide...1 1.1 Intended Readers... 1 1.2 Conventions... 1 1.3 Overview of This Guide... 1 Chapter 2 Getting Started...4
IES-3080/3062 Series. Industrial 8-port managed Ethernet switch. Features. Introduction
IES-3080/3062 Series Features Industrial 8-port managed Ethernet switch Fastest Redundant Ethernet Ring: O-Ring (recovery time < 10ms over 250 units of connection) Open-Ring supports the other vendor s
SG70660M Web Smart 6-Port Gigabit Ethernet Switch with one mini-gbic Port. Installation Guide
SG70660M Web Smart 6-Port Gigabit Ethernet Switch with one mini-gbic Port Installation Guide February 2006 VERSITRON, Inc. 83 Albe Drive / Suite C Newark, DE 19702 www.versitron.com SG70660M Rev. B The
netis Web Management Switch User's Guide Manual Version:1.1: 2015-03-12-1
netis Web Management Switch User's Guide Manual Version:1.1: 2015-03-12-1 1 COPYRIGHT & TRADEMARKS Specifications are subject to change without notice. NETIS is a registered trademark of NETCORE Technologies
EGS7228P. Business Class EGS7228P. 24-port Gigabit AT PoE + 4SFP Smart Switch PRODUCT OVERVIEW
24-port Gigabit AT PoE + 4SFP Smart Switch PRODUCT OVERVIEW EnGenius Smart PoE Switch family is special tailored for Access Points and IP surveillance applications., one of the members from EnGenius Smart
ProSafe Plus Switch Utility
ProSafe Plus Switch Utility User Guide 350 East Plumeria Drive San Jose, CA 95134 USA September 2010 202-10524-03 v1.0 ProSafe Plus Switch Utility User Guide 2010 NETGEAR, Inc. All rights reserved. No
Supports O-Ring (recovery time < 30ms over 250 units of connection) and MSTP(RSTP/STP compatible) for Ethernet
DGS-9168GP-AIO_S 16x10/100/1000Base-T(X) and 8x100/1000Base-X, SFP socket, LC connector bypass Features Supports O-Ring (recovery time < 30ms over 250 units of connection) and MSTP(RSTP/STP compatible)
16x10/100/1000Base-T(X) ports and 8x100/1000Base-X, SFP socket
IGS-9168GP Industrial 24-port managed Gigabit Ethernet switch with 16x10/100/1000Base-T(X) ports and 8x100/1000Base-X, SFP socket Features Supports O-Ring (recovery time < 30ms over 250 units of connection)
Supports O-Ring (recovery time < 30ms over 250 units of connection) and MSTP(RSTP/STP compatible) for Ethernet
IGS-9812GP Series Industrial 20-port managed Gigabit Ethernet switch with 8x10/100/1000Base-T(X) ports and 12x100/1000Base-X, SFP socket Features Supports O-Ring (recovery time < 30ms over 250 units of
8-port 10/100Base-TX +2-port 100Base-FX Switch. User s Guide
8-port 10/100Base-TX +2-port 100Base-FX Switch User s Guide COPYRIGHT All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted in any form or by
AT-S105 Version 1.2.0 Management Software Release Notes AT-FS750/24POE and AT-FS750/48 Fast Ethernet WebSmart Switches
AT-S105 Version 1.2.0 Management Software Release Notes AT-FS750/24POE and AT-FS750/48 Fast Ethernet WebSmart Switches Please read this document before you begin to use the management software. NOTE This
RGPS-7084GP-P. Industrial 12-port rack-mount managed Gigabit PoE Ethernet switch with 8x10/100/1000Base-T(X) P.S.E. ports and 4x1000Base-X, SFP socket
Rack-Mount Managed Gigabit PoE v1.2 / Dec, 2011 Features Supports O-Ring (recovery time < 30ms over 250 units of connection), MSTP/RSTP/STP (IEEE 802.1s/w/D) for Ethernet Redundancy Supports Jumbo frame
HARTING mcon 1000 Introduction and features
Introduction and features HARTING mcon 1000 es, managed, for mounting onto top-hat mounting rail in control cabinets General Description Features Supporting Ethernet (10 Mbit/s), Fast Ethernet (100 Mbit/s)
Ethernet Link SGI-4844F
Ethernet Link SGI-4844F 44 ports 100/1000Mbps SFP + 4 Combo port RJ-45 + 100/1000Mbps SFP slot Layer 2+ Managed Ethernet Switch Overview LinkPro SGI-4844F is a layer-2+ gigabit access switch equipped with
Quick Start Guide. Cisco Small Business. 200E Series Advanced Smart Switches
Quick Start Guide Cisco Small Business 200E Series Advanced Smart Switches Welcome Thank you for choosing the Cisco 200E series Advanced Smart Switch, a Cisco Small Business network communications device.
Datasheet. Managed PoE+ Gigabit Switches with SFP. Models: ES-24-250W, ES-24-500W, ES-48-500W, ES-48-750W
Managed PoE+ Gigabit Switches with SFP Models: ES-24-250W, ES-24-500W, ES-48-500W, ES-48-750W Non-Blocking Throughput Switching Performance Gigabit Ethernet RJ45 and SFP+/SFP Ports Auto-Sensing IEEE 802.3af/at
FCC Certifications. CE Mark Warning
FCC Certifications This Equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable
Quick Start Guide. Cisco Small Business. 300 Series Managed Switches
Quick Start Guide Cisco Small Business 300 Series Managed Switches Welcome Thank you for choosing the Cisco 300 Series Managed Switch, a Cisco Small Business network communications device. This device
Quick Installation Guide 24-port PoE switch with 2 copper Gigabit ports and 2 Gigabit SFP ports (af Version 15.4W)
Quick Installation Guide 24-port PoE switch with 2 copper Gigabit ports and 2 Gigabit SFP ports (af Version 15.4W) Table of Contents Introduction.. Power Over Ethernet (PoE) & Features.... Unpacking and
Expert Line Managed Industrial Switch with M-Ring Function 16x 10/100 Base-TX, 2x 10/100/1000Base-T (100/1000 Base-X SFP Ports)
MICROSENS Expert Line Managed Industrial Switch with M-Ring Function 16x 10/100 Base-TX, 2x 10/100/1000Base-T (100/1000 Base-X SFP Ports) General Ethernet is an international standard that has been proven
Ethernet Link SGI-2424
Ethernet Link SGI-2424 24 Combo Ports (10/100/1000Mbps Copper and Dual-Speed SFP) + 2G TP/SFP Combo Layer 2+ Managed Gigabit Ethernet Switch Overview LinkPro SGI-2424 is a layer-2+ gigabit access switch
User Manual 24 Port PoE 10/100/1000M with 4 Combo Gigabit SFP Open Slot Web Smart Switch
User Manual 24 Port PoE 10/100/1000M with 4 Combo Gigabit SFP Open Slot Web Smart Switch FCC Warning This Equipment has been tested and found to comply with the limits for a Class-A digital device, pursuant
HARTING Ha-VIS Management Software
HARTING Ha-VIS Management Software People Power Partnership HARTING Management Software Network Management Automation IT - with mcon Switches from HARTING With the Ha-VIS mcon families, HARTING has expanded
MICROSENS. 45x45 Installation Switch for FTTO applications. Introduction. Characteristics
45x45 Installation Switch for FTTO applications MICROSENS Introduction Current versions of the 45x45 installation switch are usually employed in cable channels and floor boxes in FTTO (Fiber-to-the-office)
USER MANUAL. PingBrother EPIW104 managed passive poe switch & IP watchdog
USER MANUAL PingBrother EPIW104 managed passive poe switch & IP watchdog CONTENT Content... 2 Chapter 1... 3 1.1 Preface... 3 1.2 CE mark warning... 3 1.3 FCC warning... 4 Chapter 2... 5 2.1 Physical description...
EMS. Trap Collection Active Alarm Alarms sent by E-mail & SMS. Location, status and serial numbers of all assets can be managed and exported
EMS SmartView TM Superior Design with Real-Time Monitor and Control Trap Collection Active Alarm Alarms sent by E-mail & SMS Network Topology Network Element Discovery Network Element Configuration Location,
TP-LINK. 24-Port Gigabit Smart PoE Switch with 4 Combo SFP Slots. Overview. Datasheet TL-SG2424P. www.tp-link.com
Power Budget TP-LINK 24-Port Gigabit Smart PoE Switch with 4 Combo SFP Slots Overview The provides 24 10/100/1000Mbps ports that supports 802.3at/af-compliant PoE, with a total PoE power supply up to 180W,
ENTERASYS WEBVIEW WEB-BASED MANAGEMENT FOR THE VH-2402S/VH-2402S2 WEB MANAGEMENT GUIDE
ENTERASYS WEBVIEW WEB-BASED MANAGEMENT FOR THE VH-2402S/VH-2402S2 WEB MANAGEMENT GUIDE 9033821 Notice NOTICE Enterasys Networks reserves the right to make changes in specifications and other information
ProCurve Switch 1700-8 ProCurve Switch 1700-24
Management and Configuration Guide ProCurve Switch 1700-8 ProCurve Switch 1700-24 www.procurve.com ProCurve Series 1700 Switch Management and Configuration Guide Copyright 2007 Hewlett-Packard Development
AT-S63 and AT-S63 NE Version 1.0.0 Management Software for the AT-9400 Series Layer 2+ Gigabit Ethernet Switches Software Release Notes
AT-S63 and AT-S63 NE Version 1.0.0 Management Software for the AT-9400 Series Layer 2+ Gigabit Ethernet Switches Software Release Notes Supported Platforms Please read this document before you begin to
ALLNET ALL8944WMP Layer 2 Management 24 Port Giga PoE Current Sharing Switch
ALLNET ALL8944WMP Layer 2 Management 24 Port Giga PoE Current Sharing Switch 24-Port Giga PoE Current Sharing Pv6 and IPv4 Dual Protocol SNMP v1/v2c/v3 SSH version 2.0 Authentication TACACS+ Jumbo Frames
JetNet 5428Gv2. Features. Industrial 24FE+4G Gigabit Managed Ethernet Switch INDUSTRIAL ETHERNET RACKMOUNT SWITCH
INDUSTRIAL ETHERNET RACKMOUNT SWITCH Industrial 24FE+4G Gigabit Managed Ethernet Switch JetNet 5428Gv2 The JetNet 5428G is a 19-inch Gigabit Layer 2+ Industrial switch, equipped with 24 100 Base-TX ports
Carrier Ethernet: New Game Plan for Media Converters
Introduction IEEE Std. 802.3ah, also referred to as Ethernet in the First Mile (EFM) standard, has a well established name within the industry today. It lays out ground rules for implementing Ethernet
20 GE PoE-Plus + 4 GE PoE-Plus Combo SFP + 2 GE SFP L2 Managed Switch, 370W
GEP-2672 Version: 1 20 GE PoE-Plus + 4 GE PoE-Plus Combo SFP + 2 GE SFP L2 Managed Switch, 370W The LevelOne GEP-2672 is a Layer 2 Managed switch with 24 x 1000Base-T PoE-Plus ports associated with 4 x
Manageable 10/100/1000 Mbs Ethernet Modular Multi-Media Switch
Manageable 10/100/1000 Mbs Ethernet Modular Multi-Media Switch CMX-2400G SNMP/Web Manageable, Modular Switch chassis with two GBIC slots Features: Modules with eight 10/100 UTP or LC Fiber ports: CMX-8TX,
48-10/100Mbps + 4G Ethernet Web Smart Switch FGSW-4840S. User s Manual
48-10/100Mbps + 4G Ethernet Web Smart Switch FGSW-4840S User s Manual Trademarks Copyright PLANET Technology Corp. 2004. Contents subject to revision without prior notice. PLANET is a registered trademark
EtherDevice Switch EDS-726 Series
Managed Redundant EtherDevice TM Switch Solutions EtherDevice Switch EDS-726 Series 26-Port Gigabit Ethernet Switch Modular, Managed, Redundant Features Industrial Networking Capability Redundant Gigabit
IGS-9812GP. Industrial 20-port managed Gigabit Ethernet switch with 8x10/100/1000Base-T(X) ports and 12x100/1000Base-X, SFP socket.
DIN-Rail Managed Gigabit v1.0 Jan, 2013 Features Supports O-Ring (recovery time < 30ms over 250 units of connection) and MSTP(RSTP/STP compatible) for Ethernet Redundancy Open-Ring support the other vendor
SonicOS Enhanced 5.7.0.2 Release Notes
SonicOS Contents Platform Compatibility... 1 Key Features... 2 Known Issues... 3 Resolved Issues... 4 Upgrading SonicOS Enhanced Image Procedures... 6 Related Technical Documentation... 11 Platform Compatibility
ProSAFE 8-Port and 16-Port Gigabit Click Switch
ProSAFE 8-Port and 16-Port Gigabit Click Switch Model GSS108E and GSS116E User Manual March 2015 202-11520-01 350 East Plumeria Drive San Jose, CA 95134 USA Support Thank you for selecting NETGEAR products.
NMS300 Network Management System
NMS300 Network Management System User Manual June 2013 202-11289-01 350 East Plumeria Drive San Jose, CA 95134 USA Support Thank you for purchasing this NETGEAR product. After installing your device, locate
AT-S95 Version 1.0.0.35 AT-8000GS Layer 2 Stackable Gigabit Ethernet Switch Software Release Notes
AT-S95 Version 1.0.0.35 AT-8000GS Layer 2 Stackable Gigabit Ethernet Switch Software Release Notes Please read this document before you begin to use the management software. Supported Platforms The following
How To Switch In Sonicos Enhanced 5.7.7 (Sonicwall) On A 2400Mmi 2400Mm2 (Solarwall Nametra) (Soulwall 2400Mm1) (Network) (
You can read the recommendations in the user, the technical or the installation for SONICWALL SWITCHING NSA 2400MX IN SONICOS ENHANCED 5.7. You'll find the answers to all your questions on the SONICWALL
Alcalde # 1822 Col. Miraflores C.P. 44270 Guadalajara, Jal. México MX 01 (33) 3854-5975 y 3823-4349 USA 001 (858)-869-5401 (Chulavista, CA.
Tu Sitio de Automatización! LBJetNet385628G Introduction The LBJetNet385628G is an Industrial Modular Managed Ethernet Switch, equipped with 3 modular slot for maximum 24 10/100 Base-TX Ports or 18 100Base-FX
IES-P3073GC Series. Industrial IEC 61850-3 10-port managed Ethernet switch with 7x10/100Base-T(X) and 3xGigabit combo ports, SFP socket.
DIN-Rail Managed v1.41 / Dec, 2011 IES-P3073GC Series Features Designed for power substation / Railway application and fully compliant with the requirement of IEC 61850-3 and IEEE 1613 World s fastest
5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual
5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual Content Overview... 1 Introduction... 1 Features... 3 Packing List... 4 Safety Precaution... 4 Hardware Description... 5 Front Panel...
Monitoring and Analyzing Switch Operation
B Monitoring and Analyzing Switch Operation Contents Overview..................................................... B-3....................................... B-4 Menu Access To Status and Counters.........................
Cisco Small Business Managed Switches
Cisco SRW208MP 8-Port 10/100 Ethernet Switch: WebView/Max PoE Cisco Small Business Managed Switches Secure, Reliable, Intelligent Switch with PoE for Your Growing Small Business Highlights Connects up
Intel Express 460T Standalone Switch
Intel Express 460T Standalone Switch User Guide Copyright 2001, Intel Corporation. All rights reserved. Intel Corporation, 5200 NE Elam Young Parkway, Hillsboro OR 97124-6497 Intel Corporation assumes
Managed Switch Quick Start Guide
Managed Switch Quick Start Guide Note: The purpose of this guide is to help you get your Hirschmann managed switch up & running as quickly as possible and recommend switch settings that are suitable for
Cisco SRW2024P 24-Port Gigabit Switch: WebView/PoE Cisco Small Business Managed Switches
Cisco SRW2024P 24-Port Gigabit Switch: WebView/PoE Cisco Small Business Managed Switches Reliable, Intelligent Switching for Growing Businesses Highlights 24 high-speed ports optimized for the network
3.5 EXTERNAL NETWORK HDD. User s Manual
3.5 EXTERNAL NETWORK HDD User s Manual Table of Content Before You Use Key Features H/W Installation Illustration of Product LED Definition NETWORK HDD Assembly Setup the Network HDD Home Disk Utility
AT-S84 Version 1.3.0 (1.0.0.90) Management Software for the AT-9000/24 Gigabit Ethernet Switch Software Release Notes
AT-S84 Version 1.3.0 (1.0.0.90) Management Software for the AT-9000/24 Gigabit Ethernet Switch Software Release Notes Please read this document before you begin to use the management software. Supported
Web Interface. Security Network Access Port Security. Enabling and Disabling Port Security
Security Network Access Port Security Enabling and Disabling Port Security You can enable and disable security and set the mode of operation on a port using the Port Security wizard. To access the wizard:
Broadband Router ESG-103. User s Guide
Broadband Router ESG-103 User s Guide FCC Warning This equipment has been tested and found to comply with the limits for Class A & Class B digital device, pursuant to Part 15 of the FCC rules. These limits
SecureLinx Spider Duo Quick Start Guide
SecureLinx Spider Duo Quick Start Guide SecureLinx Spider Duo Quick Start Guide SecureLinx Spider Duo QUICK START GUIDE CONTENTS Overview... 2 What s In The Box... 3 Installation and Network Settings...
AT-S45 Version 1.0.7 Management Software for the AT-9410GB Gigabit Ethernet Switches. Software Release Notes
AT-S45 Version 1.0.7 Management Software for the AT-9410GB Gigabit Ethernet Switches Product Documentation Software Release Notes Please read this document before you begin to use the AT-S45 management
10 Port L2 Managed Gigabit Ethernet Switch with 2 Open SFP Slots - Rack Mountable
10 Port L2 Managed Gigabit Ethernet Switch with 2 Open SFP Slots - Rack Mountable StarTech ID: IES101002SFP The IES101002SFP 10-port Ethernet switch delivers flexibility and control of your network by
Gigabit Ethernet Web Smart 8-Port Switch 2 Combo SFP Open Slot
Gigabit Ethernet Web Smart 8-Port Switch 2 Combo SFP Open Slot User s Manual (DN-80201) Content Introduction ------------------------------------------------------------------------------------4 Product
AT-S62 and AT-S62 NE Version 1.2.1 Management Software for AT-8500 Series Switches Software Release Notes
Supported Platforms AT-S62 and AT-S62 NE Version 1.2.1 Software Release Notes AT-S62 and AT-S62 NE Version 1.2.1 Management Software for AT-8500 Series Switches Software Release Notes Please read this
Starting a Management Session
Management Software AT-S63 Starting a Management Session AT-S63 Version 2.2.0 for the AT-9400 Layer 2+ Switches AT-S63 Version 3.0.0 for the AT-9400 Basic Layer 3 Switches 613-000817 Rev. A Copyright 2007
SOHOware Long Reach Ethernet (LRE) Solution
Application Note - LRE SOHOware Long Reach Ethernet (LRE) Solution LRE Technology Benefits SOHOware solution is based on Very high bit-rate DSL (VDSL) robust technology Solution supports transfer rates
User Manual. EtherUSB
User Manual EtherUSB USB Ethernet Access Point for PDA V 2.0 Clarinet Systems, Inc. Clarinet Systems, Inc. http://www.clarinetsys.com Page 1 Publication Revision No. Control Table Rev. No. Date Contents
48 GE PoE-Plus + 2 GE SFP L2 Managed Switch, 375W
GEP-5070 Version: 1 48 GE PoE-Plus + 2 GE SFP L2 Managed Switch, 375W The LevelOne GEP-5070 is an intelligent L2 Managed Switch with 48 x 1000Base-T PoE-Plus ports and 2 x 100/1000BASE-X SFP (Small Form
Web Browser Interface User s Guide
Management Software AT-S62 Web Browser Interface User s Guide AT-8516F/SC, AT-8524M, AT-8524POE, AT-8550GB and AT-8550SP LAYER 2+ FAST ETHERNET SWITCHES VERSION 1.3.0 PN 613-000127 Rev A Copyright 2005
Cisco SLM2048 48-Port Gigabit Smart Switch Cisco Small Business Smart Switches
Cisco SLM2048 48-Port Gigabit Smart Switch Cisco Small Business Smart Switches Cost-Effective, Secure Switching with Simplified Management for Your Growing Business Highlights Easy-to-use web browser interface
TP-LINK L2 Managed Switch
NEW TP-LINK L2 Managed Switch TM NEW TL-SL3428/TL-SL3452 Overview TP-LINK JetStream TM L2 managed switch TL-SL3428/TL-SL3452 provides 24/48 10/100Mbps ports, the switch provide high performance, enterprise-level
FlexDSL MiniFlex. SHDSL.bis and Optical Mini DSLAM. SHDSL.bis and Fiber Up to 300Mbps Ddd. Ethernet. Features
SHDSL.bis and Fiber Up to 300Mbps Ddd Ethernet FlexDSL MiniFlex SHDSL.bis and Optical Mini DSLAM The FlexDSL MiniFlex platform is a special part of the Orion3 product family. Beside of having up to 10
NETWORK PRINT MONITOR User Guide
NETWORK PRINT MONITOR User Guide Legal Notes Unauthorized reproduction of all or part of this guide is prohibited. The information in this guide is subject to change without notice. We cannot be held liable
M7250P. PoE Powered. Gigabit Ethernet Media Converter 1000BASE-TX TO 1000BASE-SX/LX. Installation Guide
M7250P PoE Powered Gigabit Ethernet Media Converter 1000BASE-TX TO 1000BASE-SX/LX Installation Guide September 2009 VERSITRON, Inc. 83 Albe Drive - Suite C Newark, DE 19702 www.versitron.com www.versitron.com
LotWan Appliance User Guide USER GUIDE
LotWan Appliance User Guide USER GUIDE Copyright Information Copyright 2014, Beijing AppEx Networks Corporation The description, illustrations, pictures, methods and other information contain in this document
Dominion KX II-101-V2
Dominion KX II-101-V2 Quick Setup Guide Thank you for your purchase of the Dominion KX II-101-V2, the economical, full-featured, single-port digital KVM-over-IP device. For details on using the KX II-101-V2,
TP-LINK. 24-Port 10/100Mbps + 4-Port Gigabit L2 Managed Switch. Overview. Datasheet TL-SL3428. www.tp-link.com
TP-LINK TM 24-Port 10/100Mbps + 4-Port Gigabit L2 Managed Switch Overview TP-LINK JetStream TM gigabit L2 managed switch provides 24 10/100Mbps ports. The switch provides high performance, enterprise-level
20 GE + 4 GE Combo SFP + 2 10G Slots L3 Managed Stackable Switch
GTL-2691 Version: 1 Modules are to be ordered separately. 20 GE + 4 GE Combo SFP + 2 10G Slots L3 Managed Stackable Switch The LevelOne GEL-2691 is a Layer 3 Managed switch with 24 x 1000Base-T ports associated
AT-S41 Version 1.1.4 Management Software for the AT-8326 and AT-8350 Series Fast Ethernet Switches. Software Release Notes
AT-S41 Version 1.1.4 Management Software for the AT-8326 and AT-8350 Series Fast Ethernet Switches Software Release Notes Please read this document before you begin to use the AT-S41 management software.
How To Configure Voice Vlan On An Ip Phone
1 VLAN (Virtual Local Area Network) is used to logically divide a physical network into several broadcast domains. VLAN membership can be configured through software instead of physically relocating devices
How To Manage An Ethernet Switch On An Industrial Network
Ethernet Switch DIN-Rail Managed Gigabit PoE Ethernet Switch Features 12-port managed Gigabit PoE Ethernet switch with 8x10/100/1000Base-T(X) P.S.E. ports and 4x100/1000Base-X, SFP socket 1 Ethernet Switch
FlexDSL MiniFlex. SHDSL.bis and Optical Mini DSLAM. SHDSL.bis and Fiber Up to 300Mbps Ddd. Ethernet. Features
SHDSL.bis and Fiber Up to 300Mbps Ddd Ethernet FlexDSL MiniFlex SHDSL.bis and Optical Mini DSLAM The FlexDSL MiniFlex platform is a special part of the Orion3 product family. Beside of having up to 10
TP-LINK. Gigabit L2 Managed Switch. Overview. Datasheet TL-SG3216 / TL-SG3424. www.tp-link.com
TP-LINK TM Gigabit L2 Managed Switch TL-SG3216 / TL-SG3424 Overview TP-LINK JetStream TM gigabit L2 managed switch 3 series family consists of two switches: TL-SG3216 with 16 10/100/1000Mbps ports and
Ha-VIS FTS 3000 Introduction and features
Ha-VIS Introduction and features Ethernet Switch Ha-VIS FTS 3100s-A 10-port Ethernet Switch with Fast Track Technology configurable via USB General Description Features The Fast Ethernet Switches of the
AT-S63 Version 3.1.0 Management Software for the AT-9400 Basic Layer 3 Gigabit Ethernet Switches Software Release Notes
AT-S63 Version 3.1.0 Management Software for the AT-9400 Basic Layer 3 Gigabit Ethernet Switches Software Release Notes Please read this document before you begin to use the management software. Supported
NO SPECIFICATION SPECIFICATION COMPLIANCE RESPOND PROPOSED BY VENDOR
APPENDIX 5 TECHNICAL INFORMATION FOR EQUIPMENT 1.1 HARDWARE SPECIFICATION FOR WISMA NEGERI CORE SWITCH NO SPECIFICATION SPECIFICATION COMPLIANCE RESPOND PROPOSED BY VENDOR 1.1.1 GENERAL 1 Quantity 3 Units
TRENDnet User s Guide. Cover Page
Cover Page Table of Contents Contents Product Overview... 1 Package Contents... 1 Features... 1 Product Hardware Features... 2 Application Diagram... 3 Switch Installation... 4 Desktop Hardware Installation...
TP-LINK. JetStream 28-Port Gigabit Stackable L3 Managed Switch. Overview. Datasheet T3700G-28TQ. www.tp-link.com
TP-LINK JetStream 28-Port Gigabit Stackable L3 Managed Switch Overview TP-LINK s is an L3 managed switch designed to build a highly accessible, scalable, and robust network. The switch is equipped with
Pharos Control User Guide
Outdoor Wireless Solution Pharos Control User Guide REV1.0.0 1910011083 Contents Contents... I Chapter 1 Quick Start Guide... 1 1.1 Introduction... 1 1.2 Installation... 1 1.3 Before Login... 8 Chapter