1 Accessibility for Multi-Family Housing (Apartments) By Chris Schexnayder Course Number: 5001 Credit Hours: 1 Course Description This one hour course is intended to educate the reader on the fundamentals of accessibility requirements for multi-family (apartments) developments. Learning Objectives After completing this course you will have a better understanding of: Which accessibility regulations and/or building codes apply to multi-family construction; The basic fundamental requirements of applicable codes and regulations, and; The design and construction of multi-family projects in accordance with accessibility regulations and avoidance of costly errors.

2 Course Material I. Basic Requirements A. Subject Buildings B. Exemptions II. Exterior (Site) Requirements A. Parking B. Connecting Routes III. Common Use Amenities A. Basic Requirements B. Employee Work Areas IV. Dwelling Units A. Type A (ANSI) Dwelling Units B. Type B (FHA) Dwelling Units Introduction The Fair Housing Act which requires equality in housing was passed in It wasn t until 1991 that construction guidelines were actually published for builders to follow. The original construction guidelines are called the Fair Housing Accessibility Guidelines and contain of 7 requirements. They are as follows: Requirement 1 Accessible building entrance on an accessible route Requirement 2 Accessible and usable public and common use areas Requirement 3 Usable doors Requirement 4 Accessible route into and within the dwelling unit Requirement 5 Light switches, electrical outlets, thermostats and other environmental controls in accessible locations Requirement 6 Reinforced walls for grab bars Requirement 7 Usable kitchens and bathrooms This course will incorporate the seven requirements but is organized according to the author s real world experience and hopefully presented in a manner that is easier to understand than most building codes or regulations. It was not long after the first construction guidelines for FHA compliance were published before The Department of Housing and Urban Development (HUD) realized that more guidance was needed. Barrier Free Environments of California was contracted by HUD 2

3 to develop a more comprehensive set of construction guidelines for Fair Housing compliance. Hence the Fair Housing Act Design Manual was first published in 1996, but without any diagrams. The revised edition complete with diagrams was published in This manual is an excellent source for compliance with the Fair Housing Act construction requirements. The most current construction guidelines published by the federal government for compliance with Fair Housing construction requirements for multi-family were issued in Building codes or guidelines, like any technology, get outdated. Fortunately this is a problem with a solution. When developing the requirements for fair housing a provision for safe harbor was included. The Safe Harbor clause of the Fair Housing Act allows for other HUD approved codes to be used as safe harbors for design and construction of multi-family projects. To date, the only approved Safe Harbors other than the aforementioned HUD documents are different releases of the building code and ANSI A It is this author s opinion that the wise approach to multi-family construction is to identify a safe harbor before design of a project ever begins and to utilize the same building code that is currently in force in the jurisdiction where the project is being constructed. For example, if a municipality has adopted 2006 International Building Code, which references 2003 ANSI A117.1, then it makes sense to use these codes as safe harbor since the owner has to comply with them anyway to meet local requirements. Why would you want to design and construct a project to a code that is over 11 years old, when more current technology is available and approved by HUD? There are counter arguments of course, such as older codes are simpler and less complicated, but that is like using an old operating system for your computer. It may be simpler but it is outdated and does not work with other newer technology. Before we move on let me state that this course is just covers the basics. It is not intended to be comprehensive. The only way you are going to get a comprehensive understanding of fair housing and building code requirements for multi-family housing is to read the actual documents and to apply them in the field. They are long and boring and at times difficult to comprehend. By studying and grasping the material presented in this course you will have a broad working knowledge of accessibility requirements for apartment homes and you will know where to go for the more detailed information. I will say that gaining a good understanding of this subject is like flying an airplane, you can t do it by reading a book alone. Let s begin! 3

4 Chapter 1 - Basic Requirements A. Subject Buildings What is considered a covered dwelling unit? Buildings that consist of 4 or more single story dwelling units are covered buildings under the Fair Housing Act as well as the International Building Code. Dwelling units within covered buildings are considered covered dwelling units - that is, they are covered under the Act. If, for example a project consists of three apartments per building, and there are no buildings in the project that have 4 or more dwelling units, then the entire project is not covered. Any building on a project that has 4 or more single story dwelling units in the same building is covered, and therefore all common use amenities such as clubhouse, pool, etc. are also covered. If there are no covered buildings on a project, then the common use amenities on a site are not covered under the Act either. Elevator buildings in general require compliance at all floors served by an elevator. If a project consists of 4 levels of one story apartments and each level is served by an elevator, then one hundred percent of the units must comply with the Act. B. Exemptions Two story apartments or townhomes are exempt from compliance, unless the two story unit is located in a building served by an elevator. If that is the case then the level of the two story unit served by the elevator must comply with Requirements 3 through 7 and have a usable bathroom on the accessible level. Certain dwelling units and or buildings may be exempt from compliance due to site constraints even if there are 4 or more units per building. There are different methods allowed to determine exemption due to site conditions, both in the Fair Housing Guidelines and the Building Code. Exemptions typically have to do with existing site constraints that prohibit full compliance. The rules for site exemptions are complex and we will not go into detail in this course. Each project is different and can present unique complexities. It is wise to consult with a design professional or a qualified accessibility consultant to determine if parts of a project meet exemption criteria. Chapter 1 of the Fair Housing Design Manual gives excellent examples of different types of projects along with helpful diagrams. 4

5 Chapter 2 Exterior Requirements A. Parking Accessible parking is required at the public parking provided at the Clubhouse. This number is determined by a chart provided in both the Americans with Disabilities Accessibility Guidelines (ADAAG) and the International Building Code (IBC). The number of accessible parking spaces is determined by the total number of parking spaces provided. Usually, one accessible parking space at the Clubhouse is sufficient since this covers up to 25 parking spaces. The requirement for van accessible spaces is one for every eight accessible parking spaces according to the ADAAG and one for every six accessible spaces per IBC. If there is just one accessible space required it must be van accessible. Accessible parking spaces include the vehicle parking area plus the adjacent access aisle or loading space. Van accessible spaces are 16 overall in width, which includes the parking space and the access aisle. Standard accessible spaces are 13 wide overall. The requirement for accessible resident parking under the FHA and the IBC is 2% of the total parking serving the covered dwelling units. As noted earlier, what units are considered covered varies depending on the particulars of a project. In a typical project without an elevator, ground level units are considered the covered units. Parking requirements under the building code determine how many total parking spaces are required and that is determined by how many apartments are provided and what occupancy types are available (i.e. one bedroom, two bedroom, etc). The number of overall parking required is not an accessibility requirement but does factor into the number accessible resident spaces. To determine the number of accessible resident parking spaces you need to know how many parking spaces are provided for the covered dwelling units. Calculation of accessible parking for apartment buildings is often simplified by architects and engineers by providing 2% of the overall parking provided for the residents. This may result in more than is actually required. Fair Housing also requires a sufficient number of visitor parking spaces. No clear guidelines are provided as to what a sufficient number is but care should be taken to ensure accessible visitor parking is provided in each general area where visitor parking is provided. The Uniform Federal Accessibility Standards (UFAS), which applies to federal and federally funded projects, stipulates 2% of the visitor parking be accessible. Under the FHA and IBC at least one of each type of parking provided shall be accessible. Examples of different types of parking include surface, carport and garage spaces. Usually most of the accessible parking spaces are provided as surface spaces (uncovered), but again, at least one of each type is required. 5

6 The IBC requires 2% of the total number of dwelling units to be Type A dwelling units. Type A dwelling units provide a higher level of accessibility than a regular FHA/Type B dwelling unit. We will discuss more about Type A unit requirements later in this course. The IBC does not require that each Type A dwelling unit have its own accessible parking space, although this is the common assumption and most projects do provide an accessible parking space near each Type A unit. Accessible parking spaces which happen to be near a Type A unit can count towards the 2% required accessible spaces. Fair Housing exempts parking garages that provide direct access to a dwelling unit from the garage; however, if direct access garages are provided for some of dwelling units, at least one of the Type A units should provide an attached accessible garage. The safest approach for calculating the number of accessible parking spaces within the multi-family site would be to follow the common practice of providing 2% of the overall resident parking as accessible parking spaces and disperse these among Type A, surface (uncovered), visitor, covered and garage. Both the accessible parking space and the adjacent access aisle or loading zone are required to be level which by definition is ¼ per foot,1:48 or 2% slope. Accessible parking spaces that are too steep is one of the most common violations found in new construction whether it be commercial or apartments. Each space is required to be identified with signage. Mounting heights of signs differs between codes, so it is best to follow ANSI A117.1 which requires the bottom of the parking sign to be 60 minimum above the parking surface. Such a location will meet all the codes. Care should be taken to disperse the accessible parking spaces evenly and to place them as near to building entrances as possible. B. Connecting Routes within a Site Covered dwelling units are required to be connected by an accessible pedestrian route to all common use buildings or elements on a site. Common use can be defined simply as a space or element that is used by multiple users that is, it is not for private individual use only. Typical examples of common use buildings/elements include the clubhouse, pools, recreation areas, mail kiosks, dumpsters, pet disposal stations, storage units, etc. There is an exemption which allows for a vehicle route from accessible parking spaces to common use elements. Basically, vehicular access is allowed when the finished grading between a covered dwelling unit or units and common use elements exceeds 8.3%. An accessible route between individual apartment building is not required but is recommended. It is often provided by default since the buildings are required to be connected to common areas. The key thing to keep in mind when designing and constructing accessible routes is slope. Usually connecting routes are made of concrete 6

7 or asphalt, but other materials can be utilized such as decomposed granite, provided it meets all the applicable accessibility requirements such as slope, slip resistance, and a relatively even surface. Loose or uneven materials are prohibited as part of an accessible route. Ideally every effort should be made to keep running slopes that is, slopes in the direction of travel, to 5% (1:20) or lower. This avoids the complexity of installing ramps. Ramps are parts of an accessible route that measure between 5% and 8.3% slope. Slopes exceeding 8.3% are prohibited except in some rare circumstances where existing conditions might dictate steeper slopes. Ramps that are over 6 in length require 5 level (2% max. slope) landings at the top and bottom of every run, handrails and edge protection where drop offs occur. Many builders find ramps unsightly which is one reason to keep slopes 5% or under. Cross slope is the slope that is perpendicular to the path of travel or usually side to side on a sidewalk. Cross slope issues can also occur where the accessible route crosses a driveway. Maximum cross slope allowed along an accessible route is 2% or 1:48, the same as for accessible parking spaces. After hours access to Clubhouse Business and Fitness Centers must be on an accessible route IBC requires 60% of building entrances to be accessible. The requirement used to be 50% and where there were an odd number you were expected to round up. Now, when an even number of entrances are provided for a building, a majority of accessible entrances must be provided. For example, when a building has 4 public entrances, 3 must be accessible. This is huge difference between newer and older codes since providing an accessible route to a majority of entrances can often present additional difficulties for the designer and expense for owner. Admittedly there are grey areas within all standards. Grey areas are requirements which are not clearly defined for all applications and often left open to interpretation. One grey area has to do with the 60% entrance requirement as it applies to apartment buildings. Apartments come in all shapes and sizes of course, but the most common construction seems to be a building which has two breezeways, one towards each end of a building. Often these breezeways open to both sides of the building. This type of construction provides 4 breezeway entrances to each building. If each one is considered a public entrance, then 3 of the 4 breezeway entrances must be connected by an accessible route to accessible parking and common areas within a project. It has been common practice to be satisfied with one accessible route to one end of a breezeway when site constraints or design criteria require steps at the other end. As mentioned, strict adherence to the 60% rule requires 3 out of the 4 breezeway entrances to be on an accessible route. It is best practice to strive for 60% entrances minimum however conditions may not always allow for compliance. As noted earlier, all covered dwelling units must be on an accessible route unless they qualify for the exemptions provided for in both the FHA and IBC. 7

8 All doors and gates have maneuvering clearance requirements which vary depending on what direction they are approached and the hardware provided such as latching mechanisms and automatic closers. This is applicable to gates in security fences and dumpsters as well. The maneuvering clearance area also varies depending whether a user is approaching from the push or pull side. There is text as well as diagrams in the ADAAG and ANSI which clearly depict the different maneuvering clearance requirements. What this boils down to is more concrete or wider areas at gates to ensure proper maneuvering clearances are provided. In addition, the entire maneuvering clearance area at a gate or door must not exceed 2% maximum slope in all directions. This requirement is intended to provide wheelchair users and persons with other disabilities a level surface when they stop and position themselves to open a gate or door. Chapter 3 Common Use Spaces As defined earlier, the term Common Use is pretty much as the term implies it is a space or element that is not restricted to one individual but rather a common space available to a group of people. This term can be applied to resident use areas such as Clubhouse amenities, as well as employee areas such as breakrooms. A. Basic Requirements There is often a considerable overlap between resident, employee and public spaces in a typical apartment complex. Resident spaces are those spaces mainly restricted for resident use such as the Fitness Room, and of course the apartments. Public spaces are those that would be accessible to a potential renter inquiring about a property such as the leasing office area. Employee works areas, which we will address more in the next section, are usually areas restricted mainly to employees of the business in this case an apartment complex. The topic of this section is restricted to resident common use areas. Any space or element which is available to residents of a multi-family project must be fully accessible and comply with all applicable accessibility requirements. This course will not go into detail as to the particular accessibility requirements for a particular space such as toilet rooms. In toilet rooms alone there are a multitude of individual 8

9 requirements. Currently all toilet rooms have to be accessible. Clubhouse kitchens need to be accessible which include an accessible sink (if provided) with knee clearance underneath. If a range or cooktop is provided, then an accessible work station is also required. Pools need to be accessible including any pool equipment such as life safety equipment. Both the International Building Code and the Fair Housing Act point to the American National Standards Institute (ANSI) A for the particular technical accessibility requirements for elements and spaces within common use areas. Accessibility to mailboxes can be troublesome and another grey area as noted earlier. The FHA Design Manual is pretty clear that only the mailboxes serving covered dwelling units need to be on an accessible route and be within the designated reach ranges. However, there have been Department of Justice lawsuits in which the opinion of the presiding official was that 100% of mailboxes have to be accessible. Most projects are not designed this way, unless the all dwelling units are served by an elevator which would require 100% of the dwelling units to be covered and therefore the same percentage would apply to mailboxes. Garden style apartments are usually designed so that all mail drop slots, parcel boxes and mailboxes serving the covered (typically ground floor) dwelling units are at 48 or lower. 48 is the maximum reach range allowed under current building code accessibility requirements. Current practice is to number mailboxes differently than the apartments for security purposes. In such a layout, a number of boxes equivalent to the number of covered dwelling units must be provided within accessible reach ranges and be assignable to residents occupying a covered dwelling unit upon request. When it comes to dumpsters the requirement is that a sufficient number be accessible. As noted earlier, sufficient guidance is not really provided as to what a sufficient number is. Here one has to apply a certain amount of common sense. It would be acceptable, for example, if two dumpsters where provided in the same general vicinity to have one inaccessible. Remember, dumpster gates have to provide level maneuvering clearances as described above. Currently, the sufficient number requirement also applies to recreation areas such as pools, sand volleyball courts, playgrounds, picnic areas, barbecue grills, etc. Playgrounds currently only require an accessible route to the edge of the playground surface but there are some pending guidelines which will go beyond that and require certain features of playgrounds to be accessible. Talk with the provider of your playground equipment and make an effort to meet the new guidelines rather than the minimum requirements of today. Even though the sufficient number requirement is in place for recreation areas, there should be a valid reason for not providing accessible routes to multiple features such as pools. A case could be made that providing only one accessible pool, for 9

10 instance, is discriminating against people with disabilities since pools are generally separated in different parts of the complex. B. Employee Work Areas Employee work areas within a multi-family project are required to be accessible to a certain extent under the Americans with Disabilities Act as well as the International Building Code. Employee work areas are not covered under the Fair Housing Act unless these areas are also open to the residents of the complex. For example, a manager s office might sometimes be used by residents to meet with property management. In that sense, the manager s office is covered under fair housing guidelines. The Fair Housing Act is designed to provide persons with disabilities equal housing opportunities. It is not designed to deal with the work environment. It is important to distinguish between employee work areas and employee common use areas as the requirements differ. All common use employee areas such as breakrooms and staff toilet rooms must be fully accessible. Areas used only as employee work areas have to be designed so that a wheelchair user can approach, enter and exit the space. None of the equipment within a specified work area is required to be accessible such as work stations in an office. Maintenance offices as well as toilet rooms within such an area are required to be accessible to the extent noted so far. The argument often heard against this requirement is that it is not possible for maintenance staff to perform their tasks if they are disabled, so therefore no one with a disability would ever be hired for such a position. Why design a maintenance area to be accessible? I warn able bodied people to be very cautious about assuming what persons with disabilities are and are not capable of doing. Put yourself in their position and ask whether or not you would want someone else defining your capabilities. Even though there is some sense to the argument mentioned above, there is nothing in any of the current guidelines that exempts maintenance work spaces from being on accessible route. Scenarios where it may be useful to have these spaces be accessible include temporary disabilities by maintenance staff as well as permanent disabilities by management. A person using a wheelchair is certainly capable of managing an apartment complex and might have good reason to visit the maintenance office. 10

11 Chapter 4 Dwelling Units A. Type A Dwelling Units Type A dwelling units are often referred to as ANSI units or HC units the HC standing for handicapped. Type A units are a requirement of the International Building Code, not the Fair Housing Act. Handicapped in relation to persons with disabilities is a politically incorrect term. Referring to someone with a disability as impaired such as having a visual, physical or hearing impairment is socially acceptable, at least for today. Years ago no one really gave thought to the word handicapped as implying anything negative. I recently viewed an episode of a television show called Extreme Makeover where the TV crew does a complete makeover of homes for people in need. This particular makeover was for a family with two special needs children. One of the crew was quoted as saying These people are not people with dis-abilities, they are people with different abilities. Let me take a moment briefly to explain the International Building Code. This code is written by the International Code Council (ICC). The ICC is a non-governmental business that writes building codes. They have quite a interesting history in regards to how they have evolved and have had several name changes over the years. You can learn more about them by visiting their website at Governing bodies such as municipalities have to adopt a code before it becomes effective. Most municipalities adopt a version of the International Building Code (IBC). Chapter 11 of the 2006 IBC is where most of the accessibility requirements can be found. There are some other accessibility requirements spread out through the IBC such as fire egress found in Chapter 10. Accessibility codes are broken down into two main categories scoping and technical. The scoping sections give you the general requirements such as how many, percentages, what is covered, what is exempt, etc. The technical sections give dimensional and mechanical criteria needed to design and construct something to meet compliance. The technical requirements for accessibility are published in a document called American National Standards Institute (ANSI) A Within Chapter 11 of the IBC you will find the scoping requirements for R-2, a category which includes multi-family apartments. Within the R-2 section of the IBC there is a call for 2% of the total number of dwelling units to comply with Type A requirements which can be found in the current 2003 ANSI, Chapter 10. This requirement applies to all R-2 developments with more than 20 units. Type A units must be dispersed among the different classes of units such as 1, 2 and 3 bedroom units. It does not matter if a project is covered under the FHA act as described earlier. Type A dwelling unit requirements 11

12 are separate from FHA requirements. The next section will deal with Type B units which are the IBC s equivalent of the Fair Housing units. Type A units are somewhere between a fully accessible unit and a Fair Housing Unit. They provide a higher level of accessibility than a regular Fair Housing or Type B unit. For example, all doors into and within a Type A unit have to provide maneuvering clearances. We talked about maneuvering clearances earlier in this presentation. Maneuvering clearances provide greater clearance at doors in order to make passage for wheelchair users easier, but may also benefit others such as a person using a walker. Another requirement for Type A units is to have lower sinks, kitchen work stations and lavatories. A common feature of both Type A and Fair Housing/Type B units is removable cabinets. Removable cabinets allow developers to provide a product that can be rented to anyone and easily adapted for someone as needed. A common misconception seems to be that grab bars are required in Type A units but in fact the only requirement is for blocking in the walls to accommodate grab bars. Able bodied persons may find grab bars undesirable so that is why they are not required initially. Other features that make a Type A unit unique are required turning radiuses, lower shelving, and lever hardware throughout. While FHA/Type B units allow for a dropped patio, patios within Type A units must provide an accessible threshold which provides easy access. I have never seen a sliding door threshold that meets the accessibility requirements for Type A units so therefore they should be avoided in these type units. More specific requirements for Type A units can be found in Chapter 10 of ANSI A B. FHA (Type B) Dwelling Units As mentioned, FHA dwelling units as defined in the Fair Housing Design and Construction Requirements and the Fair Housing Act Design Manual are basically the same as the Type B units required under Chapter 11 of the IBC. The scoping and technical requirements of the IBC and ANSI are basically the same as Fair Housing. There are some differences, which we will not go into detail, but this is a good reason to understand the Safe Harbor alternatives that were discussed at the beginning of this document. If a project is designed and built in accordance with a particular safe harbor, then the differences are not important. As long as the project complies with the chosen safe harbor, then the project is indeed safe. I will give one example of the differences 12

13 between the two codes. Fair Housing requires the clear floor space for kitchen appliances to be centered on the appliance. In ANSI, the clear floor space for a dishwasher is required to be offset, not centered on the appliance. This makes sense from a user standpoint when the door to the dishwasher is open. If a project is claiming safe harbor under ANSI, then the requirement for the clear floor space to be centered on this particular appliance does not apply. When fair housing guidelines were being developed, the housing developers were concerned that these requirements would produce units that were un-rentable to anyone other than the disabled community, therefore hurting their bottom line. Home builders must have had a vision of units that were very commercial looking and fully accessible such as a hospital room. Compromises were reached, and the typical FHA/Type B unit is undistinguishable from a regular unit, at least to the untrained eye. FHA/Type B units are often referred to as adaptable units because they can contain such adaptable features such as removable base cabinets and blocking for future grab bars. Requirements for FHA/Type B units are less stringent than Type A units. For example, sinks and bathroom vanities in FHA/Type B units allow for a parallel approach where Type A units have to be designed for a forward approach. There is no requirement for kitchen counter heights in FHA/Type B units. Doors within these units can have regular door knobs and closet shelves do not have to be within accessible reach ranges. Common requirements between FHA/Type B units and Type A units include mounting heights for switches, outlets and other controls such as thermostats. Also common to both is the clear width requirement at doors of 32 nominal width. Actual clear width under FHA may be as little as 31 5/8, while under ANSI it has to be 31 ¾. A minor difference of 1/8 but nonetheless a difference. Entry thresholds under the FHA can allow for a higher change in level, but most projects are designed to meet the more stringent requirement of ANSI which allows for a ½ maximum threshold with a beveled edge. Both Type A and FHA/Type B units have to be on an accessible route to common amenities. There are exemptions for Type A and FHA/Type B units which can be found in the International Building Code and the Fair Housing Guidelines. These exemptions are complicated and can relate to specifics of a project such as existing site constraints. Consult with an expert in these codes prior to making any determinations concerning the applicability of these exemptions. Summary As stated earlier, this course was meant to provide an overall understanding of the basic requirements for accessibility in multi-family apartment projects. If you are not already 13

14 intimately familiar with these guidelines and requirements, you probably can deduct from reading this material that this is no simple matter. It can be very complex and you are best advised to seek advice from an expert. Developers who think they are saving money by not using an accessibility consultant are penny wise and pound foolish. The cost of hiring a consultant should easily pay for itself. Architects can specialize in multi-family design and be very knowledgeable but they have to know many different codes and it is difficult for them to gain expertise in them all. That is why it is wise to consider hiring a qualified accessibility consultant from the beginning and keep them involved throughout a project. Thank you for taking the time to read this material. If you care to comment on this material I welcome your input. You can reach me via my website below. Chris Schexnayder President, Accessibility Design Associates, Inc. References Americans with Disabilities Act Accessibility Guidelines (ADAAG) (1992) Fair Housing Act Design and Construction Requirements (1991) Fair Housing Act Design Manual (1998) American National Standards Institute A Accessible and Usable Buildings and Facilities International Building Code (IBC) Useful Resources U.S. Department of Justice 14

15 U.S. Access Board U.S. Department of Housing and Urban Development (HUD) Fair Housing Fair Housing First (Fair Housing Technical Support) International Code Council 15

16 You must log in to to take the following test online and receive your Certificate of Completion. Find this course in your My Account page and click on Take the test. Test Questions 1. The Fair Housing Act was passed in: a b c d Requirement 7 of the Fair Housing Accessibility Guidelines deals with: a. Accessible routes between common amenities b. Parking c. Kitchens and bathrooms in covered dwelling units d. Controls and operating mechanisms 3. Which of the following are designated by HUD as safe harbors for compliance with the Fair Housing Act. a. Fair Housing Accessibility Guidelines b. Fair Housing Design Manual c IBC, 1998 ANSI d IBC, 2003 ANSI e. All of the above 4. Two story townhomes and condos that are not served by an elevator are exempt from Fair Housing compliance. a. True b. False 16

17 5. Under Fair Housing, the number of accessible parking spaces required for resident parking of an apartment complex equals: a. 2% of the total number of parking spaces provided b. 2% of the number of parking spaces serving covered dwelling units c. 2% of each type of parking provided d. None of the above 6. The maximum slope allowed in an accessible parking space and adjacent access aisle (loading zone) is: a. 5% b. 2% c. 3.3% d. 8.3% 7. Under Fair Housing guidelines, different apartment buildings on the same site are required to be connected to each other by an accessible route. a. True b. False 8. When finished grading between dwelling units and common amenities such as a mail kiosk exceeds, then vehicular access between such units is acceptable. a. 5% b. 8.3% c. 2% d. None of the above. An accessible route is always required between apartment buildings and common use amenities. 9. Maintenance offices located on an apartment complex are not required to be on an accessible route. a. True b. False 17

18 10. Type A dwelling units are a requirement under the Fair Housing Act. a. True b. False 11. Removable cabinets are an acceptable option in Fair Housing, Type B and Type A units. a. True b. False 12. Grab bars are required upon initial construction for which of the following unit types. a. Type B b. Fair Housing c. Type A d. None of the above 13. Type B units as required under the IBC are intended to be the equivalent of a Fair Housing covered dwelling unit. a. True b. False 18

Accessible Public and Common Use Areas

Accessible Public and Common Use Areas Participant Manual (888) 341-7781 (V/TTY) - Technical Guidance www.fairhousingfirst.org 2005-2006 Designed and Developed by: The BearingPoint Team for U.S. Dept. of Housing and Urban Development C-OPC-22667

More information

Common ADA Errors and Omissions in New Construction and Alterations

Common ADA Errors and Omissions in New Construction and Alterations U.S. Department of Justice Civil Rights Division Disability Rights Section Common ADA Errors and Omissions in New Construction and Alterations Introduction The ADA requires that new construction and alterations

More information

Strategies for Compliant Bathrooms

Strategies for Compliant Bathrooms (888) 341-7781 (V/TTY) - Technical Guidance www.fairhousingfirst.org 2005-2006 Designed and Developed by: The BearingPoint Team for U.S. Dept. of Housing and Urban Development C-OPC-22667 October 2005

More information

REQUIREMENT 5. Light Switches, Electrical Outlets, Thermostats, and Other Environmental Controls in Accessible Locations

REQUIREMENT 5. Light Switches, Electrical Outlets, Thermostats, and Other Environmental Controls in Accessible Locations Chapter Five: REQUIREMENT 5 Light Switches, Electrical Outlets, Thermostats, and Other Environmental Controls in Accessible Locations 5...covered multifamily dwellings with a building entrance on an accessible

More information

Accessibility and Universal Design. Presented by Jack D. Humburg Boley Centers, Inc.

Accessibility and Universal Design. Presented by Jack D. Humburg Boley Centers, Inc. Accessibility and Universal Design Presented by Jack D. Humburg Boley Centers, Inc. 1 Jack Humburg Director of Housing Development Director of ADA Services Fair Housing Education and Outreach Consultant

More information

Common ADA Errors and Omissions in New Construction and Alterations

Common ADA Errors and Omissions in New Construction and Alterations Common ADA Errors and Omissions in New Construction and Alterations Learning Objectives Course Number: 6002 Credit Hours: 1 After completing this course you will have a better understanding of numerous

More information

New York City Department of Buildings

New York City Department of Buildings The New NYC Building Code Chapter 11 Accessibility New York City Department of Buildings Technical Affairs Keith Wen, R.A. Copyright Materials This presentation is protected by US and International Copyright

More information

Chapter Seven: REQUIREMENT 7. Usable Kitchens and Bathrooms PART A: Usable Kitchens PART B: Usable Bathrooms

Chapter Seven: REQUIREMENT 7. Usable Kitchens and Bathrooms PART A: Usable Kitchens PART B: Usable Bathrooms Chapter Seven: REQUIREMENT 7 Usable Kitchens and Bathrooms PART A: Usable Kitchens PART B: Usable Bathrooms 7 PART A: Usable Kitchens 7a...covered multifamily dwellings with a building entrance on an accessible

More information

Welcome to the AccessibilityOnline Webinar Series. A collaborative program between the National Network of ADA Centers and the. U.S.

Welcome to the AccessibilityOnline Webinar Series. A collaborative program between the National Network of ADA Centers and the. U.S. Welcome to the AccessibilityOnline Webinar Series A collaborative program between the National Network of ADA Centers and the US Access Board The Session is Scheduled to begin at 2:30pm Eastern Time We

More information

REQUIREMENT 3. Usable Doors

REQUIREMENT 3. Usable Doors Chapter Three: REQUIREMENT 3 Usable Doors 3...covered multifamily dwellings with a building entrance on an accessible route shall be designed in such a manner that all the doors designed to allow passage

More information

ADA Guide for Small Businesses

ADA Guide for Small Businesses U.S. Small Business Administration Office of Entrepreneurial Development U.S. Department of Justice Civil Rights Division Americans with Disabilities Act ADA Guide for Small Businesses The U.S. Small Business

More information

City of Wichita, Kansas Americans with Disabilities Act Transition Plan Main Library Address

City of Wichita, Kansas Americans with Disabilities Act Transition Plan Main Library Address City of Wichita, Kansas Americans with Disabilities Act Transition Plan Main Library Address July 005 Prepared by DMCG Disability Management Consulting Group L.L.C. 801 Jonquil Place Columbia, MO 650 In

More information

ADA Design Guide Washrooms & Showers

ADA Design Guide Washrooms & Showers ADA Design Guide Washrooms & Showers Accessories Faucets Showers Toilets Lavatories interactive version available at bradleycorp.com/adaguide.pdf Accessible Stall Design There are many dimensions to consider

More information

Lori Greene, AHC/CDC, CCPR, FDAI

Lori Greene, AHC/CDC, CCPR, FDAI Lori Greene, AHC/CDC, CCPR, FDAI Manager, Codes & Resources 25+ years in the industry 20 years with Allegion and Ingersoll Rand Security Technologies Previous Positions Specification Team Leader New England

More information

ADA Checklist for Polling Places

ADA Checklist for Polling Places U.S. Department of Justice Civil Rights Division Disability Rights Section Americans with Disabilities Act ADA Checklist for Polling Places February 2004 Reproduction Reproduction of this document is encouraged.

More information

UNIVERSAL DESIGN CHECKLIST

UNIVERSAL DESIGN CHECKLIST Community Development and Sustainability Department 23 Russell Boulevard, Suite 2 Davis, California 95616 Phone: (530)757-5610 Fax: (530)757-5660 TDD: (530)757-5666 Website: www.cityofdaivs.org/cdd Email:

More information

Adult Family Home (AFH) LOCAL BUILDING INSPECTION CHECKLIST Code References: 2012 IRC Section R325 (WAC 51-51) APPLICATION NUMBER:

Adult Family Home (AFH) LOCAL BUILDING INSPECTION CHECKLIST Code References: 2012 IRC Section R325 (WAC 51-51) APPLICATION NUMBER: Adult Family Home (AFH) LOCAL BUILDING INSPECTION CHECKLIST Code References: 2012 IRC Section R325 (WAC 51-51) APPLICATION NUMBER: SECTIONS 1, 2, 3, AND 4 MUST BE COMPLETED BY APPLICANT BEFORE INSPECTION

More information

Compliance Guide. For Title III of the Americans with Disabilities Act

Compliance Guide. For Title III of the Americans with Disabilities Act Compliance Guide For Title III of the Americans with Disabilities Act The use of the term ADA Compliant herein is a description of a class of product designs and is not intended as a substitute for your

More information

Base Cabinet with Self-storing Folding Doors and Floor

Base Cabinet with Self-storing Folding Doors and Floor Usable Kitchens When designing a kitchen for use by persons with mobility impairments, especially those who use wheelchairs, careful layout of the kitchen is crucial to maintaining accessibility. People

More information

City of Riverside Building & Safety Division Phone: (951) 826-5697 www.riversideca.gov

City of Riverside Building & Safety Division Phone: (951) 826-5697 www.riversideca.gov City of Riverside Building & Safety Division Phone: (951) 826-5697 www.riversideca.gov BUILDING CODE REQUIREMENTS FOR CHILD DAY CARE The purpose of this document is to provide the user with a basic level

More information

Kitchen Planning Guidelines With Access Standards

Kitchen Planning Guidelines With Access Standards Kitchen Planning Guidelines With s 1: Door/Entry The clear opening of a doorway should be at least 32 wide. This would require a minimum 2-10 door. The clear opening of a doorway should be at least 34.

More information

Florida Building Code 2004 SECTION 1009 STAIRWAYS AND HANDRAILS

Florida Building Code 2004 SECTION 1009 STAIRWAYS AND HANDRAILS Florida Building Code 2004 SECTION 1009 STAIRWAYS AND HANDRAILS 1009.1 Stairway width. The width of stairways shall be determined as specified in Section 1005.1, but such width shall not be less than 44

More information

ADA Scoping: New Construction

ADA Scoping: New Construction U. S. A CCESS B O A R D T E C H N I C A L G U I D E ADA Scoping: This guide provides an introduction to the scoping requirements that form the basis for the Department of Justice s 2010 ADA Standards and

More information

Area of Rescue Assistance Communication System ADA Code Applicable excerpts:

Area of Rescue Assistance Communication System ADA Code Applicable excerpts: Area of Rescue Assistance Communication System ADA Code Applicable excerpts: CONTENTS (Guidelines and Definitions) Page 1 Area of Rescue Assistance Requirements Page 2 Emergency Communication Equipment

More information

American Academy of Physical Medicine and Rehabilitation Site Survey Report

American Academy of Physical Medicine and Rehabilitation Site Survey Report American Academy of Physical Medicine and Rehabilitation Site Survey Report Introduction and Background In early 2013, the Contract Meeting Manager for the American Academy of Physical Medicine and Rehabilitation

More information

City of Auburn Americans with Disabilities Act (ADA) Transition Plan for Curb Ramps, Sidewalks, and Pedestrian Signals ADA TRANSITION PLAN

City of Auburn Americans with Disabilities Act (ADA) Transition Plan for Curb Ramps, Sidewalks, and Pedestrian Signals ADA TRANSITION PLAN Americans with Disabilities Act (ADA) Transition Plan for Curb Ramps, Sidewalks, and Pedestrian Signals ADA TRANSITION PLAN December 21, 2009 Public Works Department 171 N. Ross Street, Suite 200 Auburn,

More information

Serving All: A Guide to Being Accessible for Your Customers and Community

Serving All: A Guide to Being Accessible for Your Customers and Community Serving All: A Guide to Being Accessible for Your Customers and Community About This Guidebook Did you know that over 70,000 people in Washington, DC have a disability? Making sure your restaurant is accessible

More information

U.S. DEPARTMENT OF HOUSING & URBAN DEVELOPMENT OFFICE OF FAIR HOUSING & EQUAL OPPORTUNITY UFAS ACCESSIBILITY CHECKLIST

U.S. DEPARTMENT OF HOUSING & URBAN DEVELOPMENT OFFICE OF FAIR HOUSING & EQUAL OPPORTUNITY UFAS ACCESSIBILITY CHECKLIST Facility Name Name of Reviewer(s) Address Date(s) of Review Unit/Apartment Number Date Building was Built Telephone Number Date(s) of Renovations, if any TDD/TTY Number (Any structure built after July

More information

Accessibility Guide for Small Businesses

Accessibility Guide for Small Businesses . Accessibility Guide for Small Businesses June 2015 Second Edition Preface This document is intended to provide explanation and technical guidance to assist owners of small businesses of the accessibility

More information

PEOPLE FIRST. How to Plan Events Everyone Can Attend. Braille Accessible Print Assistive Listening Systems

PEOPLE FIRST. How to Plan Events Everyone Can Attend. Braille Accessible Print Assistive Listening Systems PEOPLE FIRST How to Plan Events Everyone Can Attend Braille Accessible Print Assistive Listening Systems Closed Captioning Accessibility Sign Language Interpretation Information Telephone Typewriter (TTY

More information

Education for All: The Cost of Accessibility

Education for All: The Cost of Accessibility Education for All: The Cost of Accessibility The goal of Education for All (EFA) is to provide universal access to primary education throughout the world. To accomplish this goal, as many as 10 million

More information

Bath Planning Guidelines With Access Standards

Bath Planning Guidelines With Access Standards Bath Planning Guidelines With s 1: Door/Entry The clear opening of a doorway should be at least 32. This would require a minimum 2-10 door. If the existing structure precludes changing the opening then

More information

9.8.1.1. General (1) This Section applies to the design and construction of interior and exterior stairs, steps, ramps, railings and guards.

9.8.1.1. General (1) This Section applies to the design and construction of interior and exterior stairs, steps, ramps, railings and guards. Section 9.8. Stairs, Ramps, Handrails and Guards 9.8.1. Application 9.8.1.1. General (1) This Section applies to the design and construction of interior and exterior stairs, steps, ramps, railings and

More information

BUILDING REGULATIONS GUIDANCE NOTE NHBC BUILDING CONTROL

BUILDING REGULATIONS GUIDANCE NOTE NHBC BUILDING CONTROL BUILDING REGULATIONS GUIDANCE NOTE NHBC BUILDING CONTROL ACCESS TO AND USE OF BUILDINGS Parts M and K* to the Building Regulations require that people, regardless of disability, age or gender are able

More information

Expanding Your Market

Expanding Your Market U.S. Department of Justice Civil Rights Division Disability Rights Section Expanding Your Market Maintaining Accessible Features in Retail Establishments Introduction More than 50 million Americans with

More information

The emergency provisions affect the following Building Code sections:

The emergency provisions affect the following Building Code sections: On August 1, 2012 new emergency chapter 11B code provisions became effective. Attached are copies of the emergency express terms and the applicable figures. The new requirements are underlined and deleted

More information

Fair Housing in Pinellas County

Fair Housing in Pinellas County Fair Housing in Pinellas County Pinellas County Board of County Commissioners Pinellas County Affirmative Action Committee Pinellas County Office of Human Rights and the City of St. Petersburg City of

More information

ACCESSIBILITY CHAPTER 11

ACCESSIBILITY CHAPTER 11 CHAPTER 11 ACCESSIBILITY SECTION 1101 GENERAL 1101.1 Scope. The provisions of this chapter shall control the design and construction of facilities for accessibility to physically disabled persons. 1101.2

More information

ADA POST INSPECTION CHECKLIST. Job No. Route County Location

ADA POST INSPECTION CHECKLIST. Job No. Route County Location ADA POST INSPECTION CHECKLIST Job No. Route County Location SIDEWALKS All sidewalks constructed within the project limits are ADA compliant. Sidewalks are 5 or greater in width. Exception, existing sidewalks

More information

Construction of 86 Dummer Street: Questions and Answers for Trustman Residents

Construction of 86 Dummer Street: Questions and Answers for Trustman Residents Construction of 86 Dummer Street: Questions and Answers for Trustman Residents July, 2014 Introduction The Brookline Housing Authority (BHA) realized five years ago that the Trustman parking lot is large

More information

Walking and Working Surface Checklist:

Walking and Working Surface Checklist: Walking and Working Surfaces Purpose: This information is presented to improve the level of safety in our operations, and to inform you that we will comply with the OSHA Standard 29 CFR 1910.23. Responsibility:

More information

Significant Changes to the 2013 California Building Code Chapter 11B accessibility standards

Significant Changes to the 2013 California Building Code Chapter 11B accessibility standards Significant Changes to the 2013 California Building Code Chapter 11B accessibility standards Last updated: 4/8/13 The Division of State Architect s (DSA) office has recently posted the Final Approved Express

More information

Universal Design Recommendations for Accessible University Settings. Mauricio A. Lizama, Ph.D., ATP

Universal Design Recommendations for Accessible University Settings. Mauricio A. Lizama, Ph.D., ATP INFORME TÉCNICO Unidad de Diseño, Desarrollo y Evaluación de AT PRATP Septiembre, 2009 Universal Design Recommendations for Accessible University Settings Mauricio A. Lizama, Ph.D., ATP The features listed

More information

ACCESSIBILITY CHAPTER 11

ACCESSIBILITY CHAPTER 11 CHAPTER 11 ACCESSIBILITY SECTION BC 1101 GENERAL 1101.1 Scope. The provisions of this chapter and Appendices E, N and P shall control the design and construction of facilities for accessibility to persons

More information

Building an Accessible and Inclusive School Community

Building an Accessible and Inclusive School Community School Leadership Program Tool Kit Building an Accessible and Inclusive School Community Grades 6 to 12 School Leadership Program Tool Kit Table of Contents Welcome to Together We Rock!...4 Acknowledgements...6

More information

ZONING ADMINISTRATOR BULLETIN NO. 9. Relevant Code Sections:

ZONING ADMINISTRATOR BULLETIN NO. 9. Relevant Code Sections: Bicycle Parking Requirements: Design and Layout Section 307 of the Planning Code mandates the Zoning Administrator to issue and adopt such rules, regulations and interpretations as are in the Zoning Administrator

More information

Integrated Accessibility Standards Regulation:

Integrated Accessibility Standards Regulation: Integrated Accessibility Standards Regulation: A Training Booklet for Small Private and Not-for-Profit Organizations www.accessforward.ca July 2013 Disclaimer This training resource is not legal advice

More information

DUKE UNIVERSITY/DUKE UNIVERSITY HEALTH SYSTEM GUIDELINES FOR INSTALLING NEW PUBLIC TELEPHONES

DUKE UNIVERSITY/DUKE UNIVERSITY HEALTH SYSTEM GUIDELINES FOR INSTALLING NEW PUBLIC TELEPHONES DUKE UNIVERSITY/DUKE UNIVERSITY HEALTH SYSTEM GUIDELINES FOR INSTALLING NEW PUBLIC TELEPHONES Decision makers within Duke University departments should review this document prior to replacing or adding

More information

Accessibility Design Advice

Accessibility Design Advice Accessibility Design Advice Quick Access Guide Improving the accessibility of the physical environment Websites It is good practise to provide written information on your web site for disabled visitors

More information

Format for scrutinising the Hill Station Building Applications ( Current File No. 24911/2001-HSBA) The application shall be accompanied by

Format for scrutinising the Hill Station Building Applications ( Current File No. 24911/2001-HSBA) The application shall be accompanied by Format for scrutinising the Hill Station Building Applications ( Current File No. 24911/2001-HSBA) 1 2 3 4 5 I. Tamil Nadu Districts Municipalities (Hill Stations) Building Rules 1993. Rules Required Available

More information

604 Water Closets and Toilet Compartments

604 Water Closets and Toilet Compartments 604 Water Closets and Toilet Compartments 604.1 General. Accessible water closets and toilet compartments shall comply with Section 604. 604.2 Location. The water closet shall be positioned with a wall

More information

Outdoor and Recreational Accessibility. Presented by Ian Brown, Lehigh Valley Center for Independent Living

Outdoor and Recreational Accessibility. Presented by Ian Brown, Lehigh Valley Center for Independent Living Outdoor and Recreational Accessibility Presented by Ian Brown, Lehigh Valley Center for Independent Living This presentation provides an overview, and may not address your ADA situation. Presentation Overview

More information

Strategies to Promote Accessible Marketplaces and Inclusive Workplaces

Strategies to Promote Accessible Marketplaces and Inclusive Workplaces Strategies to Promote Accessible Marketplaces and Inclusive Workplaces Why should organizations include people with disabilities in their business and hiring strategies? Because they cannot afford not

More information

Building Codes Update: The 2009 International Fire Code and the Apartment Industry

Building Codes Update: The 2009 International Fire Code and the Apartment Industry ! Building Codes Update: The 2009 International Fire Code and the Apartment Industry Apartment operators and developers should be aware of organizational changes in the 2009 edition of the International

More information

BUILDING PERMIT SPECIFICATIONS

BUILDING PERMIT SPECIFICATIONS BUILDING PERMIT SPECIFICATIONS The below noted requirements are based upon La Plata County Building Code. These specifications are not intended as a complete set of requirements, but are intended to provide

More information

Civil Engineering and Architecture (CEA) Detailed Outline

Civil Engineering and Architecture (CEA) Detailed Outline Civil Engineering and Architecture (CEA) Detailed Outline Unit 1: Overview of Civil Engineering and Architecture (23 days) Lesson 1.1: History of Civil Engineering and Architecture 1. Many features of

More information

http://www.iccsafe.org/

http://www.iccsafe.org/ Sections R311 and R312 from the 2006 International Residential Code These sections of Chapter 3 of the 2006 International Residential Code for One and Two Family Dwellings (R311 and R312) including the

More information

Botetourt County, Virginia. Frequently Asked Questions

Botetourt County, Virginia. Frequently Asked Questions Botetourt County, Virginia Development Services Construction Compliance Frequently Asked Questions Permits... 2 When is a permit required?... 2 When is a permit NOT required?... 2 Who may apply for a permit?...

More information

Number of Sides Required to Have a Handrail

Number of Sides Required to Have a Handrail Excerpt from 2012 B.C. Building Code HANDRAILS & GUARDS 9.8.7. Handrails 9.8.7.1. Required Handrails 1) Except as provided in Sentences (2) to (4), handrails shall be installed on stairs and ramps in accordance

More information

REASONABLE ACCOMMODATION. and REASONABLE MODIFICATIONS. Under the FAIR HOUSING ACT. (Self-Help Packet)

REASONABLE ACCOMMODATION. and REASONABLE MODIFICATIONS. Under the FAIR HOUSING ACT. (Self-Help Packet) REASONABLE ACCOMMODATION and REASONABLE MODIFICATIONS Under the FAIR HOUSING ACT (Self-Help Packet) An Austin Tenants Council Fair Housing Program Publication 2001 Austin Tenants Council Reasonable Accommodation

More information

Building Permits: When are they required?

Building Permits: When are they required? Building Permits: When are they required? Generally, you need to obtain a building permit from the City whenever you construct, enlarge, alter, repair, move, remove, improve, convert, or demolish a building

More information

City of Los Angeles Department of Building and Safety Disabled Access Section COMMERCIAL ACCESSIBILITY PLAN REVIEW LIST JOB ADDRESS CITY ZIP

City of Los Angeles Department of Building and Safety Disabled Access Section COMMERCIAL ACCESSIBILITY PLAN REVIEW LIST JOB ADDRESS CITY ZIP GENERAL PROJECT INFORMATION PLAN CHECK NO JOB ADDRESS CITY ZIP REVIEWED BY PHONE DATE Email NOTE: Code references are to the 2014 edition of the City of Los Angeles Building Code with July 1, 2015 Supplement

More information

Accessibility in a Residential Setting

Accessibility in a Residential Setting Accessibility in a Residential Setting Fitting Places to People Adapt-Able Design Group Recognizing Opportunity Baby boom generation is just now entering their retirement years. 33% of the population in

More information

DESIGN GUIDELINES FOR SUBSTANTIAL REHABILITATION.

DESIGN GUIDELINES FOR SUBSTANTIAL REHABILITATION. 1 DESIGN GUIDELINES FOR SUBSTANTIAL REHABILITATION. I. APPLICABILITY OF GUIDELINES. The design guidelines apply to the rehabilitation of multi-family buildings, subject to H.P.D. review and approval. The

More information

Lifemark certification guide

Lifemark certification guide Lifemark certification guide Imagine A new home that accommodates not just you and your family, with your own personal needs today, but also your wider family, friends and neighbours at any time in your

More information

2010 ADA Standards for Accessible Design. Department of Justice

2010 ADA Standards for Accessible Design. Department of Justice 2010 ADA Standards for Accessible Design Department of Justice September 15, 2010 Reproduction of this document is encouraged. This publication may be viewed or downloaded from the ADA website (www.ada.gov).

More information

Approved Document M: Part M Access to and use of buildings Volume 1 dwellings. Consultation draft. August 2014

Approved Document M: Part M Access to and use of buildings Volume 1 dwellings. Consultation draft. August 2014 Approved Document M: Part M Access to and use of buildings Volume 1 dwellings Consultation draft August 2014 i Main changes in the 2014 edition This approved document supports Requirements M4(1), M4(2)

More information

ADA ACCESSIBILITY CHECKLIST FOR EXISTING FACILITIES

ADA ACCESSIBILITY CHECKLIST FOR EXISTING FACILITIES ADA ACCESSIBILITY CHECKLIST FOR EXISTING FACILITIES Purpose of Checklist Section 504 of the Rehabilitation Act of 1973 and Title II of the Americans with Disabilities Act of 1990 (ADA), which cover state

More information

HCD Model Universal Design Local Ordinance (AB 2787)

HCD Model Universal Design Local Ordinance (AB 2787) HCD Model Universal Design Local Ordinance (AB 2787) I. Purpose and Intent [To be provided by adopting local government] II. Findings [Required by H&SC section 17959 to be provided by local government]

More information

R432. Health, Health Systems Improvement, Licensing. R432-5. Nursing Facility Construction. R432-5-1. Legal Authority. R432-5-2. Purpose.

R432. Health, Health Systems Improvement, Licensing. R432-5. Nursing Facility Construction. R432-5-1. Legal Authority. R432-5-2. Purpose. R432. Health, Health Systems Improvement, Licensing. R432-5. Nursing Facility Construction. R432-5-1. Legal Authority. This rule is promulgated pursuant to Title 26, Chapter 21. R432-5-2. Purpose. The

More information

Accessible Single Occupancy Toilet Rooms Floor Plan Examples

Accessible Single Occupancy Toilet Rooms Floor Plan Examples Accessible Single Occupancy Toilet Rooms s Chapter 11 - Accessibility Connecticut State Building Code 1999 Section 1108.2.2 The drawings on the following pages have been reproduced from handouts from the

More information

ADA. Checklist for Readily Achievable Barrier Removal. The Americans with Disabilities Act. Checklist for Existing Facilities version 2.1.

ADA. Checklist for Readily Achievable Barrier Removal. The Americans with Disabilities Act. Checklist for Existing Facilities version 2.1. Checklist for Existing Facilities version 2.1 ADA T I IT L TE S L I EI & I I II I COMPLIANCE MATERIALS To obtain additional copies of this checklist, contact your Disability and Business Technical Assistance

More information

SWIMMING POOL, SPA, & HOT TUB GUIDELINES

SWIMMING POOL, SPA, & HOT TUB GUIDELINES SWIMMING POOL, SPA, & HOT TUB GUIDELINES Pool permit cost is based on the total value of the project. See Permit Fee Schedule Table 1A. A. Adopted construction codes and installation requirements 1. 2015

More information

I N T E R N A T I O N A L R E S I D E N T I A L CO D E

I N T E R N A T I O N A L R E S I D E N T I A L CO D E Visual Interpretation Of The I N T E R N A T I O N A L R E S I D E N T I A L CO D E 2006 STAIR BUILDING CODE Portions of this document reproduce sections from the 2006 International Residential Code, International

More information

Issue ID Description No. of Credits Available. Mandatory Elements Storage of Non-recyclable Waste and Recyclable Household Waste

Issue ID Description No. of Credits Available. Mandatory Elements Storage of Non-recyclable Waste and Recyclable Household Waste 150 Code for Sustainable Homes Category 5: te Issue ID Description No. of Credits Available Mandatory Elements 1 Storage of Non-recyclable te and Recyclable Household te 4 Yes Aim To provide adequate internal

More information

California Building Code Effective January 2014 HOUSING ACCESSIBILITY ACCESSIBLE WATER CLOSETS Title 24, Part 2 1127A

California Building Code Effective January 2014 HOUSING ACCESSIBILITY ACCESSIBLE WATER CLOSETS Title 24, Part 2 1127A The following are summarized excerpts from some of the new building codes for these accessible bathroom fixtures. Please refer to the 2013 California Building Code books for more details and drawings.

More information

OCFRD TENT STANDARD 6000. This Standard operates under the authority of Orange County, Florida Ordinance and State Statutes.

OCFRD TENT STANDARD 6000. This Standard operates under the authority of Orange County, Florida Ordinance and State Statutes. 1. Authority Orange County Fire Rescue Department Tents & Membrane Structures Office of The Fire Marshall - 109 E. Church Street, Lower Level - Orlando, Florida 32801-3319 Phone: 407-836-0004 Fax: 407-836-8310

More information

BUILDING INSPECTORS INSPECTION FORM FOR CHILD CARE CENTERS

BUILDING INSPECTORS INSPECTION FORM FOR CHILD CARE CENTERS DCD-0304 Identification # Rev. 9/08 County Date of Inspection NAME OF OPERATION BUILDING INSPECTORS INSPECTION FORM FOR CHILD CARE CENTERS ADDRESS TELEPHONE: CITY STATE ZIP BUILDING INSPECTORS CERTIFICATE

More information

accessibility standard

accessibility standard Scandic s accessibility standard Here you can read our 110 point accessibility standard. It has been drawn up by carefully following the route taken by guests from the car park on through the whole hotel.

More information

RESIDENTIAL WINDOW REPLACEMENT

RESIDENTIAL WINDOW REPLACEMENT 3S258 MANNING AVENUE WARRENVILLE, IL 60555 PH: 630.393.9050 FAX 630.393.1531 RESIDENTIAL WINDOW REPLACEMENT A building permit is required for the installation or replacement of windows in a residence.

More information

Architectural Barriers

Architectural Barriers AB: Texas Accessibility Standards Architectural Barriers TEXAS ACCESSIBILITY STANDARDS (TAS) of the Architectural Barriers Act Article 9102, Texas Civil Statutes Prepared and Administered by the Policies

More information

FAIR HOUSING AND REASONABLE ACCOMMODATION

FAIR HOUSING AND REASONABLE ACCOMMODATION Fair Housing FAIR HOUSING AND REASONABLE ACCOMMODATION As a part of the property management team, it is important for Service Coordinators to know the rights and obligations residents and housing providers

More information

Residential Plan Review Emergency Vehicle Access and Water Supply Permit Information Packet

Residential Plan Review Emergency Vehicle Access and Water Supply Permit Information Packet Residential Plan Review Emergency Vehicle Access and Water Supply Permit Information Packet 1. Definitions a. AHJ Authority Having Jurisdiction. The Fire Chief or Fire Marshal of a given Fire District

More information

Access to and use of buildings

Access to and use of buildings The Building Regulations 2010 Access to and use of buildings APPROVED DOCUMENT M Volume 1: Dwellings M4(1) Category 1: Visitable dwellings M4(2) Category 2: Accessible and adaptable dwellings M4(3) Category

More information

The replacement or modification of existing windows shall comply with the following requirements:

The replacement or modification of existing windows shall comply with the following requirements: City of La Habra Heights Building Division 1245 N. Hacienda Road La Habra Heights, CA 90631 Office: (562) 694-6302 ext. 228 Fax: (562) 690-5010 WINDOW REPLACEMENT 2010 CALIFORNIA RESIDENTIAL CODE (CRC)

More information

JOINT STATEMENT OF THE DEPARTMENT OF HOUSING AND URBAN DEVELOPMENT AND THE DEPARTMENT OF JUSTICE REASONABLE MODIFICATIONS UNDER THE FAIR HOUSING ACT

JOINT STATEMENT OF THE DEPARTMENT OF HOUSING AND URBAN DEVELOPMENT AND THE DEPARTMENT OF JUSTICE REASONABLE MODIFICATIONS UNDER THE FAIR HOUSING ACT U.S. DEPARTMENT OF JUSTICE CIVIL RIGHTS DIVISION U.S. DEPARTMENT OF HOUSING AND URBAN DEVELOPMENT OFFICE OF FAIR HOUSING AND EQUAL OPPORTUNITY Washington, D.C. March 5, 2008 JOINT STATEMENT OF THE DEPARTMENT

More information

CHAPTER 5 - "R1" SINGLE-FAMILY RESIDENTIAL DISTRICT

CHAPTER 5 - R1 SINGLE-FAMILY RESIDENTIAL DISTRICT CHAPTER 5 - "R1" SINGLE-FAMILY RESIDENTIAL DISTRICT Section 5-1. Regulations: The regulations set forth in this chapter, or set forth elsewhere in this ordinance when referred to in this chapter, are the

More information

Disabled Access Guide

Disabled Access Guide Disabled Access Guide The Royal Hotel South Parade Weston-Super-Mare Somerset BS23 1JP Tel: 01934 423 100 Fax : 01934 415 135 Email: Web: reservations@royalhotelweston.com www.royalhotelweston.com Location

More information

ACCESS AUDIT OF WESTPORT HOUSE

ACCESS AUDIT OF WESTPORT HOUSE ACCESS AUDIT OF WESTPORT HOUSE Large sign on the highway to indicate the entrance to Purbeck District Council Large and wide entrance Entrance showing sign for opening times Entrance sign Main entrance

More information

Physical Address/Intersection: Name of Project: Within a NFIP 100/500yr Floodzone:

Physical Address/Intersection: Name of Project: Within a NFIP 100/500yr Floodzone: Choctaw Date Recorded: Permit # RESIDENTIAL - BUILDING Permit APPLICATION Physical Address/Intersection: Name of Project: Within a NFIP 100/500yr Floodzone: YES NO Sec., Township, Range/Subdivision: Acres/Block:

More information

Advanced Fair Housing Act OR The Seven Deadly Sins of the FHA HELP! HELP! HELP! What s happening? What s changing? Will it ever get updated?

Advanced Fair Housing Act OR The Seven Deadly Sins of the FHA HELP! HELP! HELP! What s happening? What s changing? Will it ever get updated? Advanced Fair Housing Act OR The Seven Deadly Sins of the FHA What s happening? What s changing? Will it ever get updated? What Does it all Mean? What About the Other Codes? HELP! HELP! HELP! The attached

More information

2012 Ontario Building Code Requirements for New Construction. Bradford West Gwillimbury Building Division March 5, 2012

2012 Ontario Building Code Requirements for New Construction. Bradford West Gwillimbury Building Division March 5, 2012 2012 Ontario Building Code Requirements for New Construction Bradford West Gwillimbury Building Division March 5, 2012 1 Ontario Building Code changes Applicable to permits applied for after December 31,

More information

2012 IBC & 2012 NFPA 101 Significant Means of Egress Changes. Questions. 1004.1 Design Occupant Load. 1005 - Means of Egress Capacity Determination

2012 IBC & 2012 NFPA 101 Significant Means of Egress Changes. Questions. 1004.1 Design Occupant Load. 1005 - Means of Egress Capacity Determination 2012 IBC & 2012 NFPA 101 Significant Means of Egress Changes Clay Aler, P.E. Principal caler@koffel.com Andrew M. Schneider, P.E. Senior Fire Protection Engineer aschneider@koffel.com Questions Submit

More information

504/ADA SELF-EVALUATION AND ASSURANCE OF COMPLIANCE. 504/ADA General Information. Instructions

504/ADA SELF-EVALUATION AND ASSURANCE OF COMPLIANCE. 504/ADA General Information. Instructions 504/ADA SELF-EVALUATION AND ASSURANCE OF COMPLIANCE 504/ADA General Information Federal and State laws prohibit discrimination based on disability. Section 504 of the Rehabilitation Act of 1973, as amended

More information

Retirement Goals Thinking about Retirement?

Retirement Goals Thinking about Retirement? What're you doing after work? Pre-retirement planning 2-5 Retirement Goals Thinking about Retirement? Here are IO key questions to get you thinking about your needs and goals in retirement: 1. Is your

More information

Hotel Accessibility Pack

Hotel Accessibility Pack Hotel Accessibility Pack Thank you for considering the Hilton Dublin City. We are pleased to provide you with some information regarding our hotel that you may find useful when planning your visit to our

More information

RADAR. 227 www.ncdirect.co.uk

RADAR. 227 www.ncdirect.co.uk RADAR solutions RADAR RADAR Key System 228 RADAR Lockset 229 RADAR Cover Plate 229 RADAR Padlock 230 RADAR Automatic Toilet Entry System 231 RADAR Ramp 231 RADAR Ramp Sign 231 227 www.ncdirect.co.uk RADAR

More information

Kirkland Zoning Code 113.25

Kirkland Zoning Code 113.25 Kirkland Zoning Code 113.25 Chapter 113 COTTAGE, CARRIAGE AND TWO/THREE-UNIT HOMES Sections: 113.05 User Guide 113.10 Voluntary Provisions and Intent 113.15 Housing Types Defined 113.20 Applicable Use

More information

KBC Chapter 34 : Applying the Kentucky Building Code to Existing and Historic Buildings

KBC Chapter 34 : Applying the Kentucky Building Code to Existing and Historic Buildings KBC Chapter 34 : Applying the Kentucky Building Code to Existing and Historic Buildings Presented by: Kentucky Department of Housing, Buildings, and Construction Kentucky Heritage Council Louisville Metro

More information

Upper Southampton Township Department of Licenses and Inspections 939 Street Rd. Southampton, Pa. 18966 Phone: 215-322-9700 Fax: 215-322-5842

Upper Southampton Township Department of Licenses and Inspections 939 Street Rd. Southampton, Pa. 18966 Phone: 215-322-9700 Fax: 215-322-5842 Upper Southampton Township Department of Licenses and Inspections 939 Street Rd. Southampton, Pa. 18966 Phone: 215-322-9700 Fax: 215-322-5842 APPLICATION for ZONING and BUILDING PERMIT APPLICATION INSTRUCTIONS:

More information