1 PLANNING, PROPERTY AND DEVELOPMENT DEPARTMENT New House Construction Guide to the plans required when applying for a Building Permit November 2015

2 contents Introduction 3 Site Plan 4 Floor Plan 5 Foundation Plan 6 Floor Framing Plan 9 Section Drawing 10 Elevation Drawing 11 Ventilation 12 Material Specifications 13 2 Every effort has been made to ensure the accuracy of information contained in this booklet. However, in the event of a discrepancy between this booklet and the governing City of Winnipeg By-law, the By-law will take precedence.

3 This booklet is a guide to the type of plans that are required by the Plan Examination Branch when applying for a building permit to construct a basic new home. This booklet does not cover all code requirements. Reference should be made to the City of Winnipeg Building By-law and the Manitoba Building Code for the complete set of code requirements. How many sets of plans will be required? Two sets of plans must be presented upon permit application. Will the homeowner be required to obtain the services of a Professional Engineer? A professional engineer will be required to seal the plans when: a) there are any variations from the minimum standards contained within the building code, OR; b) the construction involves the use of certain structural components (eg. steel beams, glulam beams, microlam beams, LVL beams, I-joist floors, suspended wood floors, tall walls (walls exceeding 11 ft. 10 in.), pre-cast concrete/wood/steel brackets, pile foundations, etc.), OR; c) where in the opinion of the Authority Having Jurisdiction the nature of the work is complex. introduction Does the building permit include any electrical or plumbing work that is being completed? The building permit does NOT include the electrical or plumbing work that is being done. Permits for this type of work must be applied for separately. Who may apply for electrical and plumbing permits? Permits for electrical and plumbing work may be applied for by: a) the owner of a detached single family dwelling who will also be the occupant and who will be performing their own work. The permits must be obtained prior to starting the work. Information on the plans required and code requirements for this type of work may be found in the brochures Electrical Installations or Plumbing Installations, or; b) an electrical or plumbing contractor licensed by the City of Winnipeg. 3

4 4site plan What information should be indicated on the site plan? The site plan should have the following information (see FIGURE 1): a) street names, lot dimensions, civic address, legal description, and north arrow; b) dimensions from building to property lines (building to building if applicable); c) on irregular shaped lots, dimensions from property lines to the closest projections within side yards must be included; d) dimensions of all projections, such as alcoves, canopies, eaves, decks, fireplaces, landings, steps, wing walls, etc.; e) locations of downspouts (DP) and sump pump discharge (SPD) - the sump pump discharge outlet will not be permitted on the side of the foundation adjacent to a public sidewalk; f) the dimensions and locations of accessory structures (examples are detached garages, sheds, air-conditioning units) that are included in the permit application; g) the dimension, location and type of surface of existing and proposed approaches, driveways and vehicle parking areas; h) construction accesses other than lane; i) location and dimensions of registered easements (eg. swales, land drainage sewer/catch basin lead); j) the site plan paper size should be 8 1 / 2 x 11 in. or 8 1 / 2 x 14 in. Note: The site plan and construction drawings must match. FIGURE 1 - Typical Site Plan

5 What is required to be shown on the floor plan? This plan must have the following details (see FIGURE 2): a) size and type of rooms; b) location and sizes of windows, doors, closets, etc.; (see TABLE A below) Note: windows are not permitted in walls that are located less than 1.2 m (4 ft) from the property line c) if there is a fireplace/woodstove, indicate type and location; d) size of beam/lintel in wall openings, if required. e) wired-in smoke/co alarm (SA) location - at least one required per floor level, in each bedroom, and at locations between bedroom and the remainder of the floor level (ie. hallways) floor plan *Note: 1) Each bedroom must have at least one outside window which provides an unobstructed opening of not less than 0.35 sq. m (3.77 sq. ft.) in area and no dimension less than 380 mm (15 in.). FIGURE 2 - Typical Floor Plan Bedroom (Size) Bath (Size) Bedroom (Size) SA SA SA/CO Kitchen/Dining Room (Size) Living Room (Size) Window (Size) Dimensions 5

6 foundation plan What plans are required for the foundation and do these plans need to be engineered? A typical house foundation plan and details are shown in FIGURES 3, 4 and 5. A non-engineered foundation plan will be accepted if the foundation meets the minimum code standards for wall length, wall thickness and reinforcement as shown in FIGURES 4 and 5. However, if you intend to use a variation of the design in FIGURES 4 and 5 or any of several other alternative designs including for example: piles, insulated concrete forms or a wood basement, a registered professional engineer must be retained to design and seal the plans. Additionally, a wood basement design will require that an engineer be retained to inspect and certify the installation. FIGURE 3 - Typical Foundation Plan Beam (Indicate Size) Footing (Indicate Size) SUMP PIT 2 AWAY (MIN.) Telepost (Indicate Size) SA Window (Indicate Size) 6

7 FIGURE 4 - Laterally Supported Foundation Walls 10M vertical 900 mm (3 ft.) o.c. located on inner side of wall with 25 mm (1 in.) cover min. Foundation depth below grade Min m (4 ft. 6 in.) Max m (7 ft.) 25 mm (1 in.) Bot. 1 #20 M Top 1 #20 M (Above Windows) 200 mm (8 in.) concrete wall (min. 20 MPa concrete) Mid. 1 #20 M (Below Windows) Max. Bsmt. Height 2.44 mm (8 ft.) Dowels 10M mm o.c. (2 ft. 6 in.@ 3 ft. o.c.) foundation plan 600 mm (24 in.) 230 mm (9 in.) ONE STOREY Top 1 #20 M (Above Windows) Foundation depth below grade Min m (4 ft. 6 in.) Max m (7 ft.) Bot. 1 #20 M 10M vertical 900 mm (3 ft.) o.c. located on inner side of wall with 25 mm (1 in.) cover min. 200 mm (8 in.) concrete wall (min. 20 MPa concrete) Mid. 1 #20 M (Below Windows) 25 mm (1 in.) Dowels 10M mm o.c. (2 ft. 6 in.@ 3 ft. o.c.) 710 mm (28 in.) 250 mm (10 in.) TWO STOREY 7

8 foundation plan FIGURE 5 - Laterally Unsupported Foundation Walls Foundation depth below grade Min m (4 ft. 6 in.) Max m (6 ft.) 50 mm (2 in.) cover 150 mm (6 in.) 750 mm (30 in.) Top 2 #15 M 10 M vertical 900 mm (3 ft) o.c. 230 mm (9 in.) concrete wall (min. 20 MPa concrete) Bot. 1 #20 M 230 mm (9 in.) One-Storey (Bi-Level type) NOTES: (Figure 4 and Figure 5) 1. Top of foundation shall be at least 150 mm (6 in.) above finished ground level. 2. Walls over 12 m (40 ft.) in length shall be designed by a registered professional engineer. 3. Length of supported joists shall not exceed 4.9 m (16 ft.). 4. Maximum window opening size is 1.2 m (4 ft.) and openings not to exceed 25% of the wall length. Interior Footing Sizes One-Storey mm x 750 mm x 250 mm deep (30 in. x 30 in. x 10 in. deep) Two-Storey mm x 900 mm x 300 mm deep (36 in. x 36 in. x 12 in. deep) 8

9 What details are required on the floor framing plan? The details required on this plan are as follows (see FIGURE 6): a) joist size, grade, spacing and direction; b) bridging and strapping location, blocking; c) location of openings and member sizes; d) beam sizes if not shown on foundation plan; e) pre-manufactured I-joists require submission of final I-joist layout(s) complete with engineering. What details are required on the section drawing? The following details should be indicated on the section drawing (see FIGURE 7): a) Type and thickness of materials in the roof, walls and floor construction assembly; (see appropriate tables for material selection); b) If roof is to be a truss system it shall be prefabricated and designed by a Professional Engineer. FIGURE 6 - Typical Floor Framing Plan floor framing plan 9

10 section plan FIGURE 7 - Section Drawing SHINGLES: ROOF SHEATHING: EXTERIOR FINISH: WALL SHEATHING: AIR SPACE 1 (MIN.) AIR SPACE 2 1 /2 (MIN.) ATTIC ACCESS HATCH (SIZE) WALLS: 2" o.c. INSULATION: Min. R20 VAPOUR BARRIER: 6-Mil Poly INTERIOR FINISH: PRE-FAB o.c. OR o.c. COLLAR TIES: CEILING o.c. INSULATION: Min. R50 VAPOUR BARRIER: 6-Mil Poly INTERIOR FINISH: 2.3 m (7 ft. 7 in.) MINIMUM CLEARANCE ANCHORAGE TO FOUNDATION (NOTE 3) SUBFLOOR: FOUNDATION WALL: DAMP PROOFING CONCRETE WALL FLOOR JOISTS: o.c. 2 O.C. (NOTE 2) INSULATION: Min. R20 VAPOUR BARRIER: Min. 6-Mil Poly INTERIOR FINISH: FLOOR (EXAMPLE) MIN. 3 CONCRETE SLAB MIN. 4 WEEPING TILE ON UNDISTURBED SOIL W/ 6 MIN. GRAVEL COVER ON TOP AND SIDES 6-MIL POLY 6 GRAVEL (MIN.) 10 UNDISTURBED SOIL (75KPA OR GREATER) Note: 1. Attic space shall be vented in conformance to Insulation required for dwellings where the foundation wall does not extend more than 1.2 m (4 ft.) above ground level and where natural gas is used as a heating source. 3. Joists are to be anchored to the foundation by embedment or sill plate in conformance to

11 What information should be indicated on the elevation drawing? The information to be indicated on the elevation drawing is as follows (see FIGURE 8): a) type of finish siding material; b) chimney height, if any; c) window and door location; d) indicate roof slope and overhang (OH); soffit requirements? e) guard rail height/picket spacing. FIGURE 8 - Elevations elevation plan FRONT ELEVATION REAR ELEVATION SIDE ELEVATION SIDE ELEVATION 11

12 ventilation Is it essential to adequately ventilate a house? Yes, it is important to have a properly designed heating, ventilating, and air conditioning (HVAC) system to control condensation and maintain proper indoor air quality (IAQ). This system design should be done by a HRAI Certified Designer, Professional Engineer or other designer with formal training in residential HVAC design. Heat or energy recovery ventilators (HRV S) shall be installed in all single and two family dwelling units. Phone number for the Housing Inspections Branch is The office hours for the Inspections Branch are 8:30 a.m. to 4:00 p.m. Monday to Friday. 12

13 MINIMUM THICKNESS OF ROOF SHEATHING Plywood Waferboard and Maximum Strandboard Spacing of Lumber Supports Edges Edges Edges Edges Supported Unsupported Supported Unsupported mm mm mm mm mm mm in. in. in. in. in. in /16 5 /16 3 /8 3 /8 11 / /16 3 /8 3 /8 7 /16 11 / /8 1 / 2 7 /16 1 /2 3 / 4 Column THICKNESS OF WALL SHEATHING Minimum Thickness Supports Supports Supports Supports Type of 16 in. 24 in. 400 mm 600 mm o.c. in. in. mm mm Lumber 11 / / Fibreboard Plywood Waferboard/Strandboard 3 /8 7 / /4 5 / /4 5 / material specifications Column THICKNESS OF SUBFLOORING Maximum Waferboard Spacing of Plywood and Lumber Supports Strandboard mm mm mm mm in. in. in. in /8 5 /8 11 / /8 5 /8 3 / /4 3 /4 3 /4 Column

14 material specifications CEILING JOIST SPANS Commercial Member Rafter Spacing Member Rafter Spacing Designation Grade Size 12 in. 16 in. 24 in. Size 300 mm 400 mm 600 mm (in.) ft.-in. ft.-in. ft.-in. (mm) m m m Douglas Fir No.1 2 x x Larch and 2 x x No. 2 2 x x x x Spruce- No.1 2 x x Pine- and 2 x x Fir No. 2 2 x x x x Column ROOF RAFTER SPANS Rafter not supporting ceiling (Design Roof Snow Loads for 1.5 kpa (30 psf) Commercial Member Rafter Spacing Member Rafter Spacing Designation Grade Size 12 in. 16 in. 24 in. Size 300 mm 400 mm 600 mm (in.) ft.-in. ft.-in. ft.-in. (mm) m m m Douglas Fir No.1 2 x x Larch and 2 x x No. 2 2 x x x x Spruce- No.1 2 x x Pine- and 2 x x Fir No. 2 2 x x x x Column ROOF JOIST SPANS (Design Roof Snow Loads for 1.5 kpa (30 psf) Commercial Member Rafter Spacing Member Rafter Spacing Designation Grade Size 12 in. 16 in. 24 in. Size 300 mm 400 mm 600 mm (in.) ft.-in. ft.-in. ft.-in. (mm) m m m Douglas Fir No.1 2 x x Larch and 2 x x No. 2 2 x x x x Spruce- No.1 2 x x Pine- and 2 x x Fir No. 2 2 x x x x Column

15 BUILT-UP FLOOR BEAM SPANS Supporting ONE Floor in Houses Douglas Fir-Larch Grade No. 1 & 2 Supported Joist Length Supported Joist Length Size Size of 8 ft. 10 ft. 12 ft. 14 ft. 16 ft. of 2.4 m 3.0 m 3.6 m 4.2 m 4.8 m Beam ft.-in. ft.-in. ft.-in. ft.-in. ft.-in. Beam m m m m m 3-2x x x x x x x x x x x x Spruce-Pine-Fir Grade No. 1 & 2 Supported Joist Length Supported Joist Length Size Size of 8 ft. 10 ft. 12 ft. 14 ft. 16 ft. of 2.4 m 3.0 m 3.6 m 4.2 m 4.8 m Beam ft.-in. ft.-in. ft.-in. ft.-in. ft.-in. Beam m m m m m 3-2x x x x x x x x x x x x material specifications BUILT-UP FLOOR BEAM SPANS Supporting TWO Floors in Houses Douglas Fir-Larch Grade No. 1 & 2 Size Supported Joist Length Size Supported Joist Length of 8 ft. 10 ft. 12 ft. 14 ft. 16 ft. of 2.4 m 3.0 m 3.6 m 4.2 m 4.8 m Beam ft.-in. ft.-in. ft.-in. ft.-in. ft.-in. Beam m m m m m 3-2x x x x x x x x x x x x Spruce-Pine-Fir Grade No. 1 & 2 Supported Joist Length Supported Joist Length Size Size of 8 ft. 10 ft. 12 ft. 14 ft. 16 ft. of 2.4 m 3.0 m 3.6 m 4.2 m 4.8 m Beam ft.-in. ft.-in. ft.-in. ft.-in. ft.-in. Beam m m m m m 3-2x x x x x x x x x x x x

16 material specifications FLOOR JOIST SPANS Joist Spacing Commercial Grade Member Joist Spacing Joist Spacing with Strapping Designation Size with Strapping with Bridging & Bridging (in.) 12 in. 16 in. 24 in. 12 in. 16 in. 24 in. 12 in. 16 in. 24 in. ft.-in. ft.-in. ft.-in. ft.-in. ft.-in. ft.-in. ft.-in. ft.-in. ft.-in. 2 x x x No. 1 2 x Douglas Fir 2 x and -Larch 300mm 400mm 600mm 300mm 400mm 600mm 300mm 400mm 600mm (mm) m m m m m m m m m No. 2 38x x x x x in. 16 in. 24 in. 12 in. 16 in. 24 in. 12 in. 16 in. 24 in. (in.) ft.-in. ft.-in. ft.-in. ft.-in. ft.-in. ft.-in. ft.-in. ft.-in. ft.-in. 2 x x x No. 1 2 x Spruce- 2 x and 300mm 400mm 600mm 300mm 400mm 600mm 300mm 400mm 600mm Pine- (mm) m m m m m m m m m Fir No. 2 38x x x x x Column

17 In-Person Customer Service Hours are: Tuesday to Friday 8:30 am to 4:30 pm - All Zoning, Permits and Plan Examination services are available at Unit Fort Street. Mondays 8:30 am to 4:30 pm are reserved for telephone inquiries and completed application drop-offs. This enables Zoning and Permits staff to process building and development applications received throughout the week. CUSTOMER PARKING Parking Entrance 17

18 18notes

19 notes 19

20 For more information on the plans required to build a new house please call: Plan Examination Branch PH: FAX: or City of Winnipeg Planning, Property and Development Department Unit Fort Street Winnipeg, Manitoba R3C 4X7

Wood Decks Zoning and construction requirements for open non-sheltered wood decks for residential dwellings.

Wood Decks Zoning and construction requirements for open non-sheltered wood decks for residential dwellings. PLANNING, PROPERTY AND DEVELOPMENT DEPARTMENT Wood Decks Zoning and construction requirements for open non-sheltered wood decks for residential dwellings. September 2015 2 contents General Information

More information

Sample Drawing Package for One and Two Family Dwelling Applications

Sample Drawing Package for One and Two Family Dwelling Applications Sample Drawing Package for One and Two Family Dwelling Applications For a full list of submission requirements, refer to the relevant checklist for your application found on our website: http://vancouver.ca/home-property-development/application-forms-and-checklists.aspx

More information

Basement Development Construction requirements for the development of basements in residential dwellings.

Basement Development Construction requirements for the development of basements in residential dwellings. PLANNING, PROPERTY AND DEVELOPMENT DEPARTMENT Basement Development Construction requirements for the development of basements in residential dwellings. June 2009 contents GENERAL INFORMATION 3 BUILDING

More information

4. ANCHOR BOLTS AND STRAPS a. ½" anchor bolts shall be embedded 7" into concrete a maximum of 6' on center and 12" from corners and ends of plates.

4. ANCHOR BOLTS AND STRAPS a. ½ anchor bolts shall be embedded 7 into concrete a maximum of 6' on center and 12 from corners and ends of plates. GENERAL CODE REQUIREMENTS (BASEMENTS) 1. FOOTINGS a. Footings shall be below frost line depth (42"). b. For an 8" foundation wall, footings shall be no less than 8" deep and 16" wide. c. Steel reinforcement

More information

RESIDENTIAL WOOD DECKS

RESIDENTIAL WOOD DECKS RESIDENTIAL WOOD DECKS 1 A Building Permit is required for the construction of a wood deck where the deck is more than 600 mm above grade at any point. Definition: For the purposes of this pamphlet, a

More information

The Lambton County Homeowner's BUILDING PERMIT INFORMATION GUIDE

The Lambton County Homeowner's BUILDING PERMIT INFORMATION GUIDE The Lambton County Homeowner's BUILDING PERMIT INFORMATION GUIDE BUILDING SERVICES DEPARTMENT 789 Broadway Street, Box 3000 Wyoming, ON N0N 1T0 Telephone: 519 845-0801 Toll-free: 1-866-324-6912 Fax: 519

More information

Development Services Department Building Permit & Inspection Services Shed and Garage Construction Guide for Detached and Semi-Detached Dwellings

Development Services Department Building Permit & Inspection Services Shed and Garage Construction Guide for Detached and Semi-Detached Dwellings Development Services Department Building Permit & Inspection Services Shed and Garage Construction Guide for Detached and Semi-Detached Dwellings H:/forms/handouts/bldg071.docx Shed and Garage Construction

More information

INFORMATION BULLETIN NO.

INFORMATION BULLETIN NO. Requirements for Plans Review Submittal, One- and Two-Family Dwellings INFORMATION BULLETIN NO. 100 (June 26, 1998, Revised March 26, 2009) City Planning & Development - Development Services City of Kansas

More information

A Guide to Detached Residential Garages and Residential Workshops (based on 2006 BCBC)

A Guide to Detached Residential Garages and Residential Workshops (based on 2006 BCBC) A Guide to Detached Residential Garages and Residential Workshops (based on 2006 BCBC) Note: this general guide has been prepared to assist homeowners and is not to be considered as a substitute for RDOS

More information

STANDARD OPEN PATIO COVER

STANDARD OPEN PATIO COVER STANDARD OPEN PATIO COVER BUILDING & SAFETY DIVISION 201 E. LA HABRA BLVD. LA HABRA, CA 90631 62-90-9710 Call Before You Dig 1-800-227-2600 PLEASE NOTE: This information Bulletin is made available to assist

More information

Residential Building Permits

Residential Building Permits LANE COUNTY PUBLIC WORKS Residential Building Permits LAND MANAGEMENT DIVISION 3050 N. DELTA HWY, EUGENE OR 97408 i CONTACT PHONE NUMBERS: Building Program: (541) 682-4651 Inspection Requests: (888) 299-2821

More information

A Homeowner s Guide to Building Permits

A Homeowner s Guide to Building Permits A Homeowner s Guide to Building Permits Building Division City of London 300 Dufferin Ave. P.O. Box 5035 London, ON N6A 4L9 Table of Contents What is a Building?... 3 Planning Your Project... 3 When is

More information

INFORMATION BULLETIN NO.

INFORMATION BULLETIN NO. Requirements for Plans Review Submittal, One- and Two-Family Dwellings INFORMATION BULLETIN NO. 100 June 26, 1998 (Revised June 4, 2014) City Planning & Development - Development Services City of Kansas

More information

Name of course: Residential Construction Site Management (RCSM) Level 1

Name of course: Residential Construction Site Management (RCSM) Level 1 Name of course: Residential Construction Site Management (RCSM) Level 1 Core (required courses) or Optional (elective course): Required Delivery Method: This is an online course only with no classroom

More information

Does Wall Township require an inspection by the building department on resale of a home?

Does Wall Township require an inspection by the building department on resale of a home? Selling your home Does Wall Township require an inspection by the building department on resale of a home? No. We do not require a Certificate of Continued Occupancy on the resale of home. A Smoke Detector,

More information

Residential Building Permit Process

Residential Building Permit Process Residential Building Permit Process Planning and Economic Development Department Development Services Division INTRODUCTION The City of Tulsa is committed to economic development and to being a helpful

More information

CITY OF VAUGHAN SCHEDULE O LOT GRADING DESIGN FOR RESIDENTIAL DEVELOPMENT

CITY OF VAUGHAN SCHEDULE O LOT GRADING DESIGN FOR RESIDENTIAL DEVELOPMENT Page 1 CITY OF VAUGHAN SCHEDULE O LOT GRADING DESIGN FOR RESIDENTIAL DEVELOPMENT CIVIC CENTRE 2141 MAJOR MACKENZIE DRIVE MAPLE ONTARIO L6A 1T1 905-832-2281 Page 2 SECTION 1 - GENERAL OBJECTIVES To provide

More information

Residential Adjustments. Overview 4.1

Residential Adjustments. Overview 4.1 Overview 4.1 Summary This chapter contains an overview of residential structural components, quality of construction, main dwellings, and construction types. It also provides adjustments such as wall height,

More information

Additions and Alterations

Additions and Alterations Additions and Alterations Addition and alteration construction is a miscellaneous grouping of home improvement and renovation projects that are generally geared toward the enhancement of an existing principal

More information

CITY OF BERKELEY BUILDING PERMIT DETAILED CHECKLIST

CITY OF BERKELEY BUILDING PERMIT DETAILED CHECKLIST CITY OF BERKELEY DETAILED CHECKLIST This checklist will assist you in preparing plans for submittal with a building permit application. Alterations, additions and remodeling projects may not require all

More information

BUILDING SAFETY UNIT

BUILDING SAFETY UNIT POLICY Page 1 of 5 SUBMITTAL REQUIREMENTS FOR ONE AND TWO FAMILY DWELLINGS, ADDITIONS AND RENOVATIONS All submittals shall be site specific and designed to the provisions of the 2012 International Residential

More information

Certification: Building Plans Examiner. Exam ID: B3

Certification: Building Plans Examiner. Exam ID: B3 Certification: Building Plans Examiner Exam ID: B3 Scope: A Building Plans Examiner will be responsible for reviewing submitted plans to determine if they meet the requirements of the various Building

More information

H:\forms\handouts\bldg049 1 of 11 Revised Mar 2/15/dh

H:\forms\handouts\bldg049 1 of 11 Revised Mar 2/15/dh Accessory Apartment Construction Guide For Single Detached Dwelling and Semi-Detached Dwellings that have been in existence for at least five (5) years Notes: Buildings that are less than five (5) years

More information

Pre-Drywall Inspection Report

Pre-Drywall Inspection Report SM MEDALLION INSPECTIONS helping people make informed decisions Pre-Drywall Inspection Report 5657 Garden Valley Place Milton, Georgia 30024 Prepared for Betsy and Paul Dougherty January12, 2015 Medallion

More information

Plumbing Installations A homeowner guide to the City of Winnipeg plumbing requirements for a single-family dwelling

Plumbing Installations A homeowner guide to the City of Winnipeg plumbing requirements for a single-family dwelling PLANNING, PROPERTY AND DEVELOPMENT DEPARTMENT Plumbing Installations A homeowner guide to the City of Winnipeg plumbing requirements for a single-family dwelling October 2014 contents General Information

More information

Residential Decks. Planning and Development Services Department

Residential Decks. Planning and Development Services Department Building Safety Division 8500 Santa Fe Drive Overland Park, KS 66212 (913) 895-6225 Fax (913) 895-5016 Email: permitservices@opkansas.org Planning and Development Services Department Residential Decks

More information

Attached/Detached Patio Cover/Carport

Attached/Detached Patio Cover/Carport CITY OF MANTECA COMMUNITY DEVELOPMENT DEPARTMENT 1001 West Center Street Manteca, CA 95337 FAX (209) 923-8955 Building Safety Division (209) 456-8550 Community Development/Planning Division (209) 456-8500

More information

The better way to build TM. Installation Manual. FOUNDATION SIPs & FROST WALLS SIPs

The better way to build TM. Installation Manual. FOUNDATION SIPs & FROST WALLS SIPs The better way to build TM Installation Manual FOUNDATION SIPs & FROST WALLS SIPs February 2016 PWF FOUNDATION & FROST WALL SIPs Installation Manual Table of Contents Topics General Requirements...................................

More information

Chapter 3 Pre-Installation, Foundations and Piers

Chapter 3 Pre-Installation, Foundations and Piers Chapter 3 Pre-Installation, Foundations and Piers 3-1 Pre-Installation Establishes the minimum requirements for the siting, design, materials, access, and installation of manufactured dwellings, accessory

More information

Custom 30 x 20-8 Garage Plan Plan #g233 By SDS-CAD Specialized Design Systems

Custom 30 x 20-8 Garage Plan Plan #g233 By SDS-CAD Specialized Design Systems P O Box 34 Mendon, Utah Custom 30 x 20-8 Garage Plan Plan #g233 By Page 1 Title Page Page 2 Main Floor Plan Page 3 Foundation Plan Page 4 Elevation Views Page 5 Framing and Details Page 6 Typical Section

More information

2014 British Columbia Building Code Changes

2014 British Columbia Building Code Changes District of Houston 250-845-2238 2014 British Columbia Building Code Changes A District of Houston interpretation of the 2014 Building Code Changes for 9.36 & 9.32 The following changes reflect the most

More information

2014 FLORIDA BUILDING CODE

2014 FLORIDA BUILDING CODE MINIMUM REQUIREMENTS FOR NEW 1 & 2 FAMILY RESIDENTIAL STRUCTURES (ALL PLANS MUST BE 22 X 36 ) WIND BORNE DEBRIS AREA Is the proposed structure located in the wind borne debris area? If yes, one of the

More information

BUILDING PERMIT SPECIFICATIONS

BUILDING PERMIT SPECIFICATIONS BUILDING PERMIT SPECIFICATIONS The below noted requirements are based upon La Plata County Building Code. These specifications are not intended as a complete set of requirements, but are intended to provide

More information

MUNICODE SERVICES LTD.

MUNICODE SERVICES LTD. The Preserved Wood Foundation Guide MUNICODE SERVICES LTD. Prepared by MuniCode Services Ltd. Outline and Restrictions of this Guide The following information required for the construction of Preserved

More information

Building Information Packet

Building Information Packet Code Enforcement Department 882-9225 Building Information Packet The following information has been compiled to help you as a homeowner or contractor with the various steps and requirements for a building

More information

APPLICANT / CONTACT:_

APPLICANT / CONTACT:_ New Single Family House Permit Application Office Use Only SECTION 1 PERMIT INFORMATION Project Address: (Provide at least one of the following) Please note: it can not be an intersection PROJECT ADDRESS

More information

This handout is a guide only and does not contain all of the requirements of the Minnesota State Building Code or city ordinances.

This handout is a guide only and does not contain all of the requirements of the Minnesota State Building Code or city ordinances. Residential Decks Community Development Department Building Inspections Division 5200 85 th Avenue North / Brooklyn Park, MN 55443 Phone: (763) 488-6379 / Fax: (763) 493-8171 6/15 www.brooklynpark.org

More information

9.8.1.1. General (1) This Section applies to the design and construction of interior and exterior stairs, steps, ramps, railings and guards.

9.8.1.1. General (1) This Section applies to the design and construction of interior and exterior stairs, steps, ramps, railings and guards. Section 9.8. Stairs, Ramps, Handrails and Guards 9.8.1. Application 9.8.1.1. General (1) This Section applies to the design and construction of interior and exterior stairs, steps, ramps, railings and

More information

ROOF CONSTRUCTION Roof Styles Gable Roof Hip Roof Gambrel Roof

ROOF CONSTRUCTION Roof Styles Gable Roof Hip Roof Gambrel Roof ROOF CONSTRUCTION The overall appearance of a building is greatly affected by the roof lines and the roofing materials. The designer has many standard designs to choose from and should be able to find

More information

Estimated Cost of Repair

Estimated Cost of Repair 1 Applicant: Property: Home: Business: Assessor: Applicant Number: Type of Loss: Hurricane Date Contacted: 1/18/2014 Date of Loss: 10/29/2012 Date Received: 1/14/2014 Date Inspected: 2/4/2014 Date Entered:

More information

Structure Survey Findings:

Structure Survey Findings: Structure Survey Findings: Visible portions of the following were observed: foundations; structure to walls, columns, floors, roofs, overhang posts, and columns; attached or firmly abutting decks, balconies,

More information

POST AND FRAME STRUCTURES (Pole Barns)

POST AND FRAME STRUCTURES (Pole Barns) POST AND FRAME STRUCTURES (Pole Barns) Post and frame structures. The following requirements serve as minimum standards for post and frame structures within all of the following structural limitations:

More information

When is a Permit Required? What Types of Permits are Required? The most common types of projects that require permits are:

When is a Permit Required? What Types of Permits are Required? The most common types of projects that require permits are: When is a Permit Required? The most common types of projects that require permits are: -New Houses or buildings -Room Additions or Expansions -Structural repairs, remodeling and alterations -Accessory

More information

COMMONLY USED RESIDENTIAL BUILDING CODES

COMMONLY USED RESIDENTIAL BUILDING CODES COMMONLY USED RESIDENTIAL BUILDING CODES INTERNATIONAL RESIDENTIAL CODE (2009) form revised 5/10 FOUNDATION 1. DESIGN OF FORMWORK. Section 1906.1 IBC 2009, Section R404.1.2.3.6 IRC 2009, ACI 318 Section

More information

Plumbing Installations. A homeowner guide to the City of Winnipeg plumbing requirements for a single-family dwelling

Plumbing Installations. A homeowner guide to the City of Winnipeg plumbing requirements for a single-family dwelling Plumbing Installations A homeowner guide to the City of Winnipeg plumbing requirements for a single-family dwelling February 2001 contents General Information 3 Inspection 4 New Drain and Vent Installations

More information

Chapter 6 ROOF-CEILING SYSTEMS

Chapter 6 ROOF-CEILING SYSTEMS Chapter 6 ROOF-CEILING SYSTEMS Woodframe roof-ceiling systems are the focus of this chapter. Cold-formed steel framing for a roof-ceiling system also is permitted by the IRC but will not be discussed;

More information

Basic Requirements for Residential Plan Review _

Basic Requirements for Residential Plan Review _ Basic Requirements for Residential Plan Review _ Below you will find the basic requirements for your plan submittal. General: Drawn to scale Plan Size minimum: 9 x 12 Designer, Engineer, or Architect name,

More information

Residential Deck Safety, Construction, and Repair

Residential Deck Safety, Construction, and Repair Juneau Permit Center, 4 th Floor Marine View Center, (907)586-0770 This handout is designed to help you build your deck to comply with the 2006 International Residential Building code as modified by the

More information

ENERGY STAR Qualified New Homes Thermal Enclosure Checklist. Water Management Checklist. Eli Caudill

ENERGY STAR Qualified New Homes Thermal Enclosure Checklist. Water Management Checklist. Eli Caudill ENERGY STAR Qualified New Homes Thermal Enclosure Checklist & Water Management Checklist Eli Caudill ENERGY STAR Version 3 Tighter Standards Whole Home Approach Better, More Sustainable Construction Surpasses

More information

This handout is a guide only and does not contain all of the requirements of the Minnesota State Building Code or city ordinances.

This handout is a guide only and does not contain all of the requirements of the Minnesota State Building Code or city ordinances. Basement Finishing Guide Community Development Department Building Inspections Division 5200 85 th Avenue North / Brooklyn Park, MN 55443 Phone: (763) 488-6379 / Fax: (763) 493-8171 6/15 www.brooklynpark.org

More information

Physical Address/Intersection: Name of Project: Within a NFIP 100/500yr Floodzone:

Physical Address/Intersection: Name of Project: Within a NFIP 100/500yr Floodzone: Choctaw Date Recorded: Permit # RESIDENTIAL - BUILDING Permit APPLICATION Physical Address/Intersection: Name of Project: Within a NFIP 100/500yr Floodzone: YES NO Sec., Township, Range/Subdivision: Acres/Block:

More information

PDmB, Inc. Definitions

PDmB, Inc. Definitions Page 1 of 11 Definitions S Satisfactory Meets industry standards for proper material and installation NP Not Present Condition or item was not present at time of inspection NI Not Inspected Condition or

More information

Page & Turnbull imagining change in historic environments through design, research, and technology

Page & Turnbull imagining change in historic environments through design, research, and technology DCI+SDE STRUCTURAL EVALUATIONS OFFICE BUILDING, TOOL SHED & WATER TANK, AND BLACKSMITH & MACHINE SHOP BUILDINGS SAN FRANCISCO, CALIFORNIA [14290] PRIMARY PROJECT CONTACT: H. Ruth Todd, FAIA, AICP, LEED

More information

Requirements for Building Application Submission

Requirements for Building Application Submission THE DEVELOPMENT CONTROL AND PLANNING BOARD P O Box 597 Phone: 869 465-2277 Bladen Commercial Development Fax: 869 465-5842 Basseterre, St. Kitts Email: phyplskb@caribsurf.com To: Architects, Designers

More information

Residential Plan Routing Information

Residential Plan Routing Information Residential Plan Routing Information BUILDING INSPECTIONS 800 4th AVENUE EAST WEST FARGO, ND 58078 PHONE: 701-433-5480 The building Inspection s Department receives and issues all applications for building

More information

ONE-STOP S PERMIT INFORMATION PACKAGE FOR RESIDENTIAL PROJECTS

ONE-STOP S PERMIT INFORMATION PACKAGE FOR RESIDENTIAL PROJECTS ONE-STOP S PERMIT INFORMATION PACKAGE FOR RESIDENTIAL PROJECTS This package was prepared by the Meet & Greet Office 1002 Washington Avenue 1 st Floor Houston, TX 77002 Phone: 832-394-9000 TABLE OF CONTENTS

More information

2012 Ontario Building Code Requirements for New Construction. Bradford West Gwillimbury Building Division March 5, 2012

2012 Ontario Building Code Requirements for New Construction. Bradford West Gwillimbury Building Division March 5, 2012 2012 Ontario Building Code Requirements for New Construction Bradford West Gwillimbury Building Division March 5, 2012 1 Ontario Building Code changes Applicable to permits applied for after December 31,

More information

RESIDENTIAL FOUNDATION GUIDELINE Johnson County, KS

RESIDENTIAL FOUNDATION GUIDELINE Johnson County, KS RESIDENTIAL FOUNDATION GUIDELINE Johnson County, KS Johnson County Building Officials Association January 2008 Residential Foundation Guideline Foundation designs for one-and two-family dwellings may use

More information

201 WATER STREET FORWARDERS MUSEUM AND VISITORS INFORMATION CENTRE

201 WATER STREET FORWARDERS MUSEUM AND VISITORS INFORMATION CENTRE STRUCTURAL INSPECTION REPORT DRAFT 201 WATER STREET FORWARDERS MUSEUM AND VISITORS INFORMATION CENTRE TOWN OF PRESCOTT Date: November 2013 GENIVAR No.: 131-20617-00 2611 Queensview Drive, Suite 300, Ottawa,

More information

RESIDENTIAL/COMMERICIAL ROOFING APPLICATION Date / / BUILDING PERMIT APPLICATION

RESIDENTIAL/COMMERICIAL ROOFING APPLICATION Date / / BUILDING PERMIT APPLICATION Community Development 1050 W Romeo Rd, Romeoville, IL 60446-1530 (815) 886-7200 Fax: 815/886-2724 Email: buildinginspections@romeoville.org RESIDENTIAL/COMMERICIAL ROOFING APPLICATION Date / / BUILDING

More information

Town of Beaumont. Lot Grading Guidelines

Town of Beaumont. Lot Grading Guidelines Town of Beaumont Lot Grading Guidelines LOT GRADING APPROVAL PROCESS Lot Grading Guidelines... 3 Introduction... 3 Purpose... 3 Definitions... 3 Lot Grading... 3 Lot Grading Plan... 3 Lot Grading Certificate...

More information

ROOF CONSTRUCTION Roof Styles Gable Roof Hip Roof Gambrel Roof

ROOF CONSTRUCTION Roof Styles Gable Roof Hip Roof Gambrel Roof ROOF CONSTRUCTION The overall appearance of a building is greatly affected by the roof lines and the roofing materials. The designer has many standard designs to choose from and should be able to find

More information

Fig. 2 WALL-TO-WALL PANEL CONNECTIONS CORNER WALL CONNECTION

Fig. 2 WALL-TO-WALL PANEL CONNECTIONS CORNER WALL CONNECTION SIPS SCREWS WITH MINIMUM 1" PENETRATION IN WOOD MEMBER IN SIP WALL PANEL CONNECTED TO @ 24" O.C. MAXIMUM OUTSIDE SKIN EACH SIDE OF FRAMING TYP. AS RECOMMENDED BY FOAM CORE AS EACH SIDE OF FRAMING TYP.

More information

October 30, 2014. Mr. & Mrs. Daniel Vick 101 Southwind Cove Benton, AR. Report of Findings, Structural Investigation, Benton, Arkansas, Dear Mr.

October 30, 2014. Mr. & Mrs. Daniel Vick 101 Southwind Cove Benton, AR. Report of Findings, Structural Investigation, Benton, Arkansas, Dear Mr. 117 S. Market St. Benton, AR 72015 * 501-315-2626 * Fax 501-315-0024 October 30, 2014 Mr. & Mrs. Daniel Vick 101 Southwind Cove Benton, AR Re: Report of Findings,, Benton, Arkansas, Dear Mr. Vick: This

More information

TYPICAL PATIO COVERS 111

TYPICAL PATIO COVERS 111 City of Laguna Niguel Building Division 30111 Crown Valley Pkwy Laguna Niguel, CA 92677 (949) 362-4360 FAX 362-4369 www.cityoflagunaniguel.org TYPICAL PATIO COVERS 111 PLEASE NOTE: This information Bulletin

More information

NAVAJO COUNTY ADDENDA & ADDITIONS TO THE INTERNATIONAL BUILDING CODES. Public Works/Planning & Zoning Building & Safety AMENDED (05-02-05)

NAVAJO COUNTY ADDENDA & ADDITIONS TO THE INTERNATIONAL BUILDING CODES. Public Works/Planning & Zoning Building & Safety AMENDED (05-02-05) NAVAJO COUNTY ADDENDA & ADDITIONS TO THE INTERNATIONAL BUILDING CODES Public Works/Planning & Zoning Building & Safety AMENDED (05-02-05) NAVAJO COUNTY GOVERNMENTAL COMPLEX P.O. BOX 668 HOLBROOK, ARIZONA

More information

RULING OF THE MINISTER OF MUNICIPAL AFFAIRS AND HOUSING

RULING OF THE MINISTER OF MUNICIPAL AFFAIRS AND HOUSING BUILDING CODEACT, 1992 RULING OF THE MINISTER OF MUNICIPAL AFFAIRS AND HOUSING Pursuant to clause 29(l)(b) of the Building Code Act, 1992. as amended, the Director of the Building and Development Branch

More information

A HOMEOWNERS GUIDE TO BUILDING IN GREY HIGHLANDS

A HOMEOWNERS GUIDE TO BUILDING IN GREY HIGHLANDS A HOMEOWNERS GUIDE TO BUILDING IN GREY HIGHLANDS AIM AND APPLICATION OF THE GUIDE This guide is intended to help you better understand the requirements for building as set by applicable law, which could

More information

Ontario s 2012 Building Code Division B, Part 9 (Ontario Regulation 332/12)

Ontario s 2012 Building Code Division B, Part 9 (Ontario Regulation 332/12) Ontario s 2012 Building Code Division B, Part 9 (Ontario Regulation 332/12) Notice: This e-learning module is intended for general information purposes only. It only highlights certain provisions of the

More information

NCMA TEK CONCRETE MASONRY FOUNDATION WALL DETAILS. TEK 5-3A Details (2003)

NCMA TEK CONCRETE MASONRY FOUNDATION WALL DETAILS. TEK 5-3A Details (2003) NCMA TEK National Concrete Masonry Association an information series from the national authority on concrete masonry technology CONCRETE MASONRY FOUNDATION WALL DETAILS TEK 5-3A Details (2003) Keywords:

More information

A Guide for the Homeowner/Builder

A Guide for the Homeowner/Builder A Guide for the Homeowner/Builder To repair, alter, add to or construct a new home, carport, garage, sundeck or other work Plus other related information Table of Contents 1. Introduction... 1 2. Building

More information

CITY OF FAIRFAX CODE ADMINISTRATION 703-385-7830 / FAX 703-385-9265 www.fairfaxva.gov

CITY OF FAIRFAX CODE ADMINISTRATION 703-385-7830 / FAX 703-385-9265 www.fairfaxva.gov CITY OF FAIRFAX CODE ADMINISTRATION 703-385-7830 / FAX 703-385-9265 www.fairfaxva.gov Finishing a basement to make additional living space in a house is a popular construction project for many homeowners.

More information

Building Permit Application Packet. BUILDING CODES Adopted by La Plata County For Enforcement In The Unincorporated Areas Of La Plata County

Building Permit Application Packet. BUILDING CODES Adopted by La Plata County For Enforcement In The Unincorporated Areas Of La Plata County Building Permit Application Packet The purpose of Building Codes is to establish the minimum requirements to safe guard the public health, safety and general welfare through structural strength, means

More information

Uniform Construction Code (UCC) Building Permit Application Package

Uniform Construction Code (UCC) Building Permit Application Package Uniform Construction Code (UCC) Residential Building Permit Application Package Per the Uniform Construction Code (UCC) all structures must be built per the standards of the most currently adopted International

More information

Patio Covers / Carports

Patio Covers / Carports Patio Covers / Carports Building Guides for Homeowners Why Do I need a Permit? D I D Y O U K N O W? As owner-builder you are the responsible party of record on such a permit. If your work is being performed

More information

REVEWED BY: Ross Rogien B.O/P.R. ADDITIONAL REVIEW(S) REQ.-FIRE DEPT Y/N

REVEWED BY: Ross Rogien B.O/P.R. ADDITIONAL REVIEW(S) REQ.-FIRE DEPT Y/N PLAN REVIEW FOR: PROJECT NAME: OWNER: ARCH/DESIGNER: ADDRESS: Ph/Fx: Plans Dated: E-mail: Sealed By: Estimated Project Cost - $ REVEWED BY: Ross Rogien B.O/P.R. ADDITIONAL REVIEW(S) REQ.-FIRE DEPT Y/N

More information

Superform Products Ltd.

Superform Products Ltd. TYPICAL CORNER REINFORCING NOTE : SEE ENGINEERED REBAR SCHEDULES SUPPLIED BY THE MANUFACTURER STEEL REINFORCEMENT WALL CORNER 90 Copyright 2012 Sept. 2012 5.1.1 Rebar Spacing 6" 12" Max. Load LB./FT. 2000

More information

Permits and Compliance. A reference guide for applying for Electrical, Plumbing, Gas, Private Sewage and Building Permits

Permits and Compliance. A reference guide for applying for Electrical, Plumbing, Gas, Private Sewage and Building Permits Permits and Compliance A reference guide for applying for Electrical, Plumbing, Gas, Private Sewage and Building Permits Permits and Compliance is an information guide produced and published by The Inspections

More information

2009 IECC Update. Scope. Content. International Energy Conservation Code

2009 IECC Update. Scope. Content. International Energy Conservation Code 2009 IECC Update International Energy Conservation Code Scope The code applies to both residential and commercial buildings. In the code, the United States is divided into eight climate zones which are

More information

Final inspections are completed by site visit only. Access to fenced yards shall be planned.

Final inspections are completed by site visit only. Access to fenced yards shall be planned. ROOFING RESIDENTIAL BUILDING INSPECTIONS DEPARTMENT www.ci.blaine.mn.us This handout is intended only as a guide and is based in part on the 2015 Minnesota State Building Code, Blaine City ordinances,

More information

Mark Cramer Inspection Services, Inc.

Mark Cramer Inspection Services, Inc. Mark Cramer Inspection Services, Inc. 492 Twentieth Avenue, Indian Rocks Beach, FL 34635-2970 (727) 595-4211 Fax (727) 596-7583 Certified Member #12085 American Society of Home Inspectors Construction

More information

LITITZ MUTUAL INSURANCE COMPANY 2 North Broad Street Lititz, Pennsylvania - MAIN OFFICE -

LITITZ MUTUAL INSURANCE COMPANY 2 North Broad Street Lititz, Pennsylvania - MAIN OFFICE - The original section of this building was constructed in 1941. The exterior walls are built of good quality stone. In the early 1980 s a similar addition was added to the north elevation. The exterior

More information

Uncovered Decks & Porches

Uncovered Decks & Porches Uncovered Decks & Porches Building Guides for Homeowners Why Do I need a Permit? D I D Y O U K N O W? As owner-builder you are the responsible party of record on such a permit. If your work is being performed

More information

The replacement or modification of existing windows shall comply with the following requirements:

The replacement or modification of existing windows shall comply with the following requirements: City of La Habra Heights Building Division 1245 N. Hacienda Road La Habra Heights, CA 90631 Office: (562) 694-6302 ext. 228 Fax: (562) 690-5010 WINDOW REPLACEMENT 2010 CALIFORNIA RESIDENTIAL CODE (CRC)

More information

WOODLAND HOMES BUILDING PROCESS A STEP BY STEP CONSTRUCTION GUIDE TO YOUR NEW HOME

WOODLAND HOMES BUILDING PROCESS A STEP BY STEP CONSTRUCTION GUIDE TO YOUR NEW HOME WOODLAND HOMES BUILDING PROCESS A STEP BY STEP CONSTRUCTION GUIDE TO YOUR NEW HOME 1 THE BUILDING PROCESS The focus of Woodland Homes building department is Quality, Service and Predictability. Through

More information

REQUIREMENTS FOR SUBMITTING PLANS FOR NEW CONSTRUCTION

REQUIREMENTS FOR SUBMITTING PLANS FOR NEW CONSTRUCTION RESIDENTIAL: REQUIREMENTS FOR SUBMITTING PLANS FOR NEW CONSTRUCTION 2 COMPLETE SETS OF PRINTS WITH ENGINEERS STAMP ON FOUNDATION PLAN INCLUDING ELECTRICAL, PLUMBING, ETC. SITE PLAN SHOWING HOUSE LOCATION

More information

Asphalt Shingle Application Requirements

Asphalt Shingle Application Requirements Alberta Allied Roofing Association Asphalt Shingle Application Requirements Section 1 Roof Decks 1.1 General Asphalt Shingles are not permitted to be installed directly over rigid insulation. When Asphalt

More information

Facility Assessment for. 11801 East Main Street, Huntley, IL

Facility Assessment for. 11801 East Main Street, Huntley, IL Facility Assessment for 11801 East Main Street, Huntley, IL July 12, 2012 Prepared by: Dewberry Architects Inc. 25 S. Grove Avenue, Suite 500 Elgin, IL 60120 (847) 695-5840 The Village of Huntley requested

More information

Georgia Association of Home Inspectors

Georgia Association of Home Inspectors Georgia Association of Home Inspectors Standards of Practice for Framing Inspections OVERVIEW The purpose of the GAHI (Georgia Association of Home Inspectors) Standards of Practice for Framing Inspections

More information

St. Louis County Department of Public Works Division of Code Enforcement. When is a Building Permit required for Residential Projects?

St. Louis County Department of Public Works Division of Code Enforcement. When is a Building Permit required for Residential Projects? St. Louis County Department of Public Works Division of Code Enforcement When is a Building Permit required for Residential Projects? BUILDING CONSTRUCTION WORK A Building Permit is required to construct,

More information

Bureau Veritas Contact Information

Bureau Veritas Contact Information Bureau Veritas Contact Information Permit Submittal The permit documents and fees will be submitted to the city. Submittal documents should be complete to expedite plan review and permit issuance. Please

More information

City of Morro Bay Building Division 955 Shasta Ave., Morro Bay, CA 93442-1900, 805-772-6261

City of Morro Bay Building Division 955 Shasta Ave., Morro Bay, CA 93442-1900, 805-772-6261 City of Morro Bay Building Division 955 Shasta Ave., Morro Bay, CA 93442-1900, 805-772-6261 BUILDING PERMIT APPLICATION Permit No. Type Date Project Address Parcel No. Lot Block Tract Project Description:

More information

Zoning Department DECK PERMITS. Checklist

Zoning Department DECK PERMITS. Checklist MANOR BOROUGH Zoning Department DECK PERMITS Checklist Complete Building and Electrical Permit Form. Complete Zoning Permit Form. Obtain a Plot Plan/Survey showing locaion of ALL streets, alleys, property

More information

COMMERCIAL PLAN SUBMISSION FOR NEW CONSTRUCTION AND/OR RENOVATIONS

COMMERCIAL PLAN SUBMISSION FOR NEW CONSTRUCTION AND/OR RENOVATIONS COMMERCIAL PLAN SUBMISSION FOR NEW CONSTRUCTION AND/OR RENOVATIONS Permit applicants shall submit three (3) COMPLETE SETS of plans and specifications with each application for a permit. Plans and specifications

More information

PROJECT TITLE : 2-STOREY RESIDENCE LOCATION : ALONG DAANG HARI,MOLINO.BACOOR,CAVITE OWNER : CUEVASVILLE REALTY

PROJECT TITLE : 2-STOREY RESIDENCE LOCATION : ALONG DAANG HARI,MOLINO.BACOOR,CAVITE OWNER : CUEVASVILLE REALTY PROJECT TITLE : 2-STOREY RESIDENCE LOCATION : ALONG DAANG HARI,MOLINO.BACOOR,CAVITE OWNER : CUEVASVILLE REALTY GENERAL SPECIFICATIONS These specifications are intended to cover the construction of the

More information

HURRICANE MITIGATION RETROFITS FOR EXISTING SITE-BUILT SINGLE FAMILY RESIDENTIAL STRUCTURES

HURRICANE MITIGATION RETROFITS FOR EXISTING SITE-BUILT SINGLE FAMILY RESIDENTIAL STRUCTURES HURRICANE MITIGATION RETROFITS FOR EXISTING SITE-BUILT SINGLE FAMILY RESIDENTIAL STRUCTURES 101 Retrofits Required. Pursuant to Section 553.844 553.884, Florida Statutes, strengthening of existing site-built,

More information

1/2" CDX PLY W/ 8d @ 6"/ 6"/ 12" 2x ROOF RAFTERS @ 16"OC W/ R-30 BATT. INSUL. (COMMON NAILS)

1/2 CDX PLY W/ 8d @ 6/ 6/ 12 2x ROOF RAFTERS @ 16OC W/ R-30 BATT. INSUL. (COMMON NAILS) TYPE V CONSTRUCTION IS A CLASSIFICATION OF BUILDINGS BY CONSTRUCTION MATERIALS AND METHODS. IT IS THE LEAST RESTRICTIVE PERMITTED BY THE UNIFORM BUILDING CODE AND INCLUDES LIGHT, WOOD-FRAME CONSTRUCTION.

More information

EFFECTIVE FEBRUARY 2014. note: drainage permit required to call for a dampproof inspection

EFFECTIVE FEBRUARY 2014. note: drainage permit required to call for a dampproof inspection EFFECTIVE FEBRUARY 2014 note: drainage permit required to call for a dampproof inspection 1. ROOF DRAINS/DECK DRAINS (INTERIOR ) All roof and deck drains within the perimeter of the building shall be APPROVED

More information

Free 12 x 8 Shed Plan With Illustrations, Blueprints & Step By Step Details

Free 12 x 8 Shed Plan With Illustrations, Blueprints & Step By Step Details Free 12 x 8 Shed Plan With Illustrations, Blueprints & Step By Step Details Brought To You By: MyShedPlans Click Here To Download 12,000 Shed Plans >> 12 x 8 Basic Shed This 8 12-ft. shed features a simple

More information

SUPER SHED. Indoor shelter for your outdoor tools.

SUPER SHED. Indoor shelter for your outdoor tools. SUPER SHED Indoor shelter for your outdoor tools. Not everyone needs a garden shed. But, if you've no more space on your garage wall for that new leaf rake, if you can't find your potting trowel because

More information