LTG Swirl Diffusers Type DLA. Highest Scores for Performance, Design and Price
|
|
- Derrick Hicks
- 7 years ago
- Views:
Transcription
1 LW-PROSP DLA 6s_0108_D.qxd:PROSP DLA 6s_0707_D_V :00 Uhr Seite 3 LTG Swirl Diffusers Type DLA Highest Scores for Performance, Design and Price
2 LW-PROSP DLA 6s_0108_D.qxd:PROSP DLA 6s_0707_D_V :00 Uhr Seite 4 Swirl Diffuser Typ DLA 7 Provides optimum comfort through lower room air velocity Model sizes Size of the square / round square: 400, 500, 600, 625, 800 mm round: 400, 500, 600, 625, 800 mm The is factory-preset. However, both tangential and vertical flow may easily be changed by adjusting the inside the. Tangential flow Available in any RAL colour, anodized, chrom iumd or stainless steel. 2 Example: Main hall of a bank Example: Bank Example: Shopping mall
3 LW-PROSP DLA 6s_0108_D.qxd:PROSP DLA 6s_0707_D_V :00 Uhr Seite 5 Swirl Diffuser Typ DLA 8 Quiet through optimized air flow For high flow rates Model sizes Size of the square / round square: 600, 625 mm round: 600, 625 mm The is factory-preset. However, both tangential and vertical flow may easily be changed by adjusting the inside the. Available in any RAL colour, anodized, chromiumd or stain less steel. Tangential flow Example: Book store Example: Office Example: Boutique 3
4 LW-PROSP DLA 6s_0108_D.qxd:PROSP DLA 6s_0707_D_V :59 Uhr Seite 1 LTG Swirl Diffusers Type DLA The LTG Swirl Diffuser Type DLA is a highly inductive which may be either integrated in the ceiling or freely suspended. The highly inductive multi-jet swirl diffusion offers a variety of important advantages: Reduction of high cooling loads while maintaining comfortable room conditions Precise ventilation of specific zones, such as heavily occupied areas Very comfortable, draft free conditions in occupied areas, due to low air velocity and temperature differences Economical installation due to factorypreset s For continuous best results, the can be readjusted when room conditions change, even after completed instal lation All-metal construction Diffuser available in any RAL color, galvanized, chromium-d or stainless steel Thanks to the highly inductive effect as a result of the large number of individual jets, the is suitable for both high flow rates and variable flow rate systems with low flow rates. Various flow patterns are possible: tangential or vertical flow. Easy adjustment by simply changing the flow inside the Tangential flow 1 und 2 DLA 7 Tangential flow DLA 8 With tangential flow 1 the standard flow air will remain close to the ceiling. A turbulent air pattern is being created resulting in a perfect reduction of temperature differences and speed. Tangential flow 2 (only for DLA 7) is best suited for low flow rates with high temperature differences. While the cross section is reduced, the impulse of the air is increased keeping the air close to the ceiling. Due to the long distance outside the occupied zone, the induction effect is increased. When using the vertical flow, the air is diffused conically downwards. The vertical flow is used preferably in the heating mode. Diffuser : Galvanized steel, visible side powder coated similar to RAL, chromium-d or stainless steel Swirl disc: Galvanized steel, black or white coating Recommended installation height: meters Air plenum box: Galvanized sheet steel Versions: pyramid box square box cylindrical box including an adjustable damper inside the socket*; adjustment from below through the. *not possible with a rectangular socket Duct connection: Lateral or from above through round socket (installation by customer) or lateral rectangular connection in case of low box heights. Model size Type DLA 7 square DLA 7 round DLA 8 square 4 DLA 8 round
5 LW-PROSP DLA 6s_0108_D.qxd:PROSP DLA 6s_0707_D_V :00 Uhr Seite 6 Air Plenum Box Typ P Swirl s Type DLA 7P and DLA 8P are supplied with a pyramid shaped air distribution box Type P. Swirl type DLA 7P The air plenum box type P offers many advantages: Reduction in operating cost The pyramid shaped plenum has only 50% of the surface area of a conventional square shaped one and therefore reduces the thermal losses by half. Cost advantages during installation and adjustment The LTG air plenum box type P is supplied with an integrated damper and is suited to most ceiling systems. No harmful materials from insulation Since the air plenum box type P does not require insulation, there is no danger from particles getting into the supply air. Space economy compared to square air plenum box Cost savings for transport, storage and hand ling on site Space saving approx.66% already with 3 units Comparison of the space required for 3 LTG pyramid plenums versus 3 conventional square air plenum boxes Example: Physician s office Example: Clothing store 3 DLA 8 with Perforated metal Example: Shoe store 5
6 LW-PROSP DLA 6s_0108_D.qxd:PROSP DLA 6s_0707_D_V :00 Uhr Seite 2 LTG Aktiengesellschaft Grenzstraße 7 D Stuttgart Postfach D Stuttgart y + 49 (711) Fax + 49 (711) Internet: raumluft@ltg-ag.de LTG Incorporated 101 Corporate Drive, Suite E Spartanburg, SC 29303, USA y (8 64) Fax Internet: info@ltg-inc.net LTG S.r.l. con socio unico Via G. Leopardi, 10 I Melzo y (02) Fax (02) Internet: info@ltgsrl.191.net Components for room air technology Germany Central Office (Frankfurt) Sontraer Str. 27 D Frankfurt y (0 69) Fax Bergmann@LTG-AG.de Central Office (Herborn) Sperberweg 16 D Herborn y ( ) Fax Hartmann@LTG-AG.de Office East (Berlin) Eisenhutweg 51a D Berlin y (0 30) Fax Linke@LTG-AG.de Office East (Chemnitz) Johannes-Ebert-Straße 20 D Chemnitz y (0 371) Fax Schenfeld@LTG-AG.de Office South Grenzstraße 7 D Stuttgart y (07 11) Fax Gau@LTG-AG.de Grenzstraße 7 D Stuttgart y (07 11) Fax Flaadt@LTG-AG.de Office West Baststraße 30 D Oberhausen y (02 08) Fax Perenz@LTG-AG.de Austria KTG Klimatechnische Gesellschaft mbh Schubertsraße 13 A-2126 Ladendorf y ( ) Fax ( ) office@ktg-wien.com Great-Britain MAP Motorised Air Products Ltd. Unit 5a Sopwith Crescent Wickford Business Park Wickford GB-Essex SS11 8YU y ( ) Fax info@mapuk.com Netherlands Opticlima Systems b.v. Leeuwerikstraat 110 NL-3853 AG Ermelo y (03 41) Fax (02 16) info@opticlima.nl Poland HTK Went Sp.z.o.o. ul. Chopina 13/3 PL Krakow y (012) Fax (012) info@htk-went.pl Portugal ArGelo S.A. Rua Luis Pastor De Macedo Lote 28B P Lisboa y (21) Fax (21) info@argelo.pt Switzerland Laminair AG Kirchbergstrasse 105 CH-3400 Burgdorf y (0 34) Fax (0 34) info@laminair.ch Turkey Step Müh. Yapi Ltd. Barbaros Mah. Kayacan Sokak No. 10 TR Yenisahra-Atasehir-Istanbul y (02 16) Fax (02 16) info@stepyapi.com.tr The Program for Air Conditioning Technology Key Components Air s for walls, floors and ceilings LTG System clean linear s Coandatrol ceiling air s Coanda vent displacement s LTG chilling fans cool wave induction units Klimavent fan coil units Raumluft ceiling fan coil units Ventotel facade ventilation units Univent airflow control units labair system Engineering Services Technical services for investors, architects, engineers and plant builders during design, construction and operation of buildings. Reliable and precise data relating to the ventilation or air conditioning system are given already before realization of the project, determined by measurements, calculations, building simulations and experiments. The Program for Process Air Technology Key Components Axial, centrifugal and tangential fans Fahrtwind Simulators LTG Filtration Technology: Suction nozzles Fans Dampers Filters Separators Compactors LTG Humidification Technology: Air Humidifiers Product Humidifiers Engineering Services Technical services during development and operation of assembly groups, machines and plants. Analysis, simulation, optimization. Customized solutions. Mobile Filtration Lab / Filter engineering on site (0108) Printed on chlorine-free bleached paper. Subject to technical alterations. LTG Aktiengesellschaft, Stuttgart
Air Diffusers for direct conditioning Type WDA/WDB
Air Diffusers for direct conditioning Type WDA/WDB D - 70435 Stuttgart, Grenzstraße 7 +49 (0711) 82 01-180, Fax +49 (0711) 82 01-696 Internet: http://www.ltg-ag.de E-Mail: info@ltg -AG.de LTG Incorporated
More informationDSRQ - DSRSQ - DSRSQ-THERM
DSRQ - DSRSQ - DSRSQ-THERM Specification item: Variable geometry diffuser on 597x597 mm panel developed for rooms with high ceilings where a long throw and a high induction ratio are required. Made up
More informationUnder sill units. Type FSL-B-ZAS
.1 X X testregistrierung Under sill units Type, heat recovery Centrifugal fan Adaptive heat recovery damper HYGIENISCH GETESTET V DI 022 Tested to VDI 022 Secondary air unit for supply air and extract
More informationTechnical Concept. Filter Fan Unit COMPACT. Type COMPACT AC Type COMPACT EC
Technical Concept Filter Fan Unit COMPACT Type COMPACT AC Type COMPACT EC Ultra Filter Fan Unit COMPACT Technical Concept Product Description Filter Fan Units (FFUs) from M+W Products are designed to provide
More informationHow To Make A Supply Air Ceiling
Supply air ceiling General is a supply air ceiling system with adjustable discs. The spread pattern is infinitely flexible and can be adjusted as required without affecting the airflow, pressure drop or
More informationSP/1/EN/5. Product Summary. KLIMA 1 Catalogue KLIMA 2 Catalogue FILTER Catalogue. The art of handling air
SP/1/EN/5 Product Summary KLIMA 1 Catalogue KLIMA 2 Catalogue FILTER Catalogue The art of handling air Components and Systems for Ventilation and Air Conditioning As an internationally leading manufacturer
More informationProduct Summary. KLIMA 1 Catalogue KLIMA 2 Catalogue FILTER Catalogue. The art of handling air. Special leaflet SP/1/EN/7
Product Summary KLIMA 1 Catalogue KLIMA 2 Catalogue FILTER Catalogue The art of handling air Special leaflet SP/1/EN/7 Components and systems for ventilation and air conditioning C As an internationally
More informationHVAC Systems: Overview
HVAC Systems: Overview Michael J. Brandemuehl, Ph.D, P.E. University of Colorado Boulder, CO, USA Overview System Description Secondary HVAC Systems Air distribution Room diffusers and air terminals Duct
More informationHVAC air curtains. Type InduAir
Air Conditioning Cooling Heating Ventilation HVAC air curtains Type InduAir The Energy Saving air curtain for Industrial Applications InduAir The solid, self-supporting housing of the energy saving air
More information1-Way Chilled Water Cassettes KCO 60, 90 & 120. Technical Brochure. TM KCO-W.1GB Date : November 2005 Supersedes : None
1-Way Chilled Water Cassettes KCO 60, 90 & 120 Technical Brochure TM KCO-W.1GB Date : November 2005 Supersedes : None General Features Control valve (optional) Air vent In-tube electric heating elements
More informationChilled Beam Solutions ADVANCING THE SCIENCE OF AIR DISTRIBUTION. Redefine your comfort zone. www.titus-hvac.com
Chilled Beam Solutions ADVANCING THE SCIENCE OF AIR DISTRIBUTION k-12 education Redefine your comfort zone. www.titus-hvac.com woodgrains dual-function energy solutions table of contents The CBAL-24 is
More informationINDEX. Chapter8. air master. Perforated Ceiling Diffusers
Chapter8 INDEX A. Perforated ceiling diffuser 1. Perforated ceiling diffuser with plenum box..: APCD+P...8.1. Perforated ceiling diffuser with damper....: APCD...8. Standard sizes...8. Fixing details...8.
More informationFilter Fan Unit SILENT. Type SILENT AC Type SILENT EC
Technical Concept Filter Fan Unit SILENT Type SILENT AC Type SILENT EC Filter Fan Unit SILENT Technical Concept Product Description Filter Fan Units (FFUs) from M+W Products are designed to provide clean
More informationAir-water systems for efficient air conditioning
Air-water systems for efficient air conditioning The art of handling air System overview Passive cooling systems Induction units Façade ventilation units Page 4 Page 6 Page 10 Passive Chilled ceiling Undersill
More informationLaminar Flow Panel. Type LFP 2/2.4/B/2. Telephone +44(0) 1842 754545 Telefax +44(0) 1842 763051 e-mail trox@troxuk.co.uk www.troxuk.co.
2/2./B/2 Laminar Flow Panel Type LFP TROX UK Ltd Caxton Way Thetford Norfolk IP2 3SQ Telephone +(0) 182 7555 Telefax +(0) 182 763051 e-mail trox@troxuk.co.uk www.troxuk.co.uk Contents Description Description
More informationWTW SWANTM. Linear slot air diffusers of wall-to-wall design for ceilings
SWANTM WTW Linear slot air diffusers of wall-to-wall design for ceilings Quick facts Wall-to-wall installation Diffuser face of light aluminium design 2, 3 or slots Horizontal/vertical air distribution
More informationDuct Design. Presented by Dave Janquart
Duct Design Presented by Dave Janquart Overview of Topics Duct design Duct insulation SMACNA Standards Factors Influencing Duct Design Equipment Losses Air Velocity Duct Material Duct Size & Shape Length
More informationSwirl diffuser VSKA. Product facts. Quick selection. Swirl diffuser VSKA. Connection box ATTB. Product code example:
VSKA are supply air diffusers designed for ceiling mounting. The design of the air deflectors and discharge outlets causes the air discharged by the diffuser to mix with the air in the premises (high induction
More informationGrilles & Diffusers Series LFP Incorporating
Grilles & Diffusers Incorporating Series LFP Produce a stable linear throw, creating an area of clean air with minimal diffusion Perfect for areas like clean rooms and operating theatres Tile replacer
More information2 STEPS TO CONDUCTING YOUR HVAC ASSESSMENT
Presentation Synopsis Heating, Ventilating and Air Conditioning Building Condition Assessment Vancouver, B.C. Prepared for: EPIC Prepared by: Douglas Spratt, P.Eng Douglas Spratt & Associates Ltd. www.dspratt-associates.com
More informationSECTION EG. Engineering Guide Air Distribution. Please refer to the Price Engineer s HVAC Handbook for more information on Air Distribution.
SECTION EG Air Distribution Please refer to the Price Engineer s HVAC Handbook for more information on Air Distribution. Space Air Diffusion AIR DISTRIBUTION ENGINEERING GUIDE Proper selection of air diffusion
More informationComparison between Decentralised and Centralised Air Conditioning Systems
Comparison between De and Centralised Air Conditioning Systems (Summary) FassadenSystemLüftung FassadenSystemLüftung Telephone +49/ 28 45/ 2 02-711 GmbH & Co KG Telefax +49/28 45/2 02-2 25 Heinrich-Trox-Platz
More informationElement D Services Heating, Ventilating, and Air Conditioning
PART 1 - GENERAL 1.01 OVERVIEW A. This section supplements Design Guideline Element D3041 on air handling distribution with specific criteria for projects involving design of a Data Center spaces B. Refer
More informationBasics of HVAC Cleaning
Basics of HVAC Cleaning Seminar Outline Residential 1. Types of systems used and why 2. Types of air distribution systems 3. System components 4. Determining the need for cleaning (ACR2002) 5. Project
More informationHDA -----------------------------------------------------------
----------------------------------------------------------- Lightstrips ---------------------------------------------------------------------- Ceiling system for heating and cooling LIGHTSTRIPS LIGHTSTRIPS
More informationBasic Selection & Proper Application of Overhead Air Distribution Devices
Basic Selection & Proper Application of Overhead Air Distribution Devices GRD Selection & Application Terms Selection Throw Sound Installation Variations affect Performance Inlet Effects Basics Return
More informationMethods for Effective Room Air Distribution. Dan Int-Hout Chief Engineer, Krueger Richardson, Texas
Methods for Effective Room Air Distribution Dan Int-Hout Chief Engineer, Krueger Richardson, Texas Agenda Overview LEED issues and Update Perimeter Acoustics Thermal Comfort IAQ / Standard 62.1 Update
More informationAir Conditioning in Green Office Buildings?
Air Conditioning in Green Office Buildings? How to implement Demand Controlled Ventilation Stuttgart Rechte allein bei ICEBO 08 10.10.2008 CI / DrRo 1 Air Conditioning in Green Office Buildings ventilation
More informationSPECIAL APPLICATIONS
Page 1 SPECIAL APPLICATIONS The protection of microelectronics clean rooms using aspirating smoke detection systems requires special consideration. The physical configuration of the room(s) and the direction
More informationProblem Statement In order to satisfy production and storage requirements, small and medium-scale industrial
Problem Statement In order to satisfy production and storage requirements, small and medium-scale industrial facilities commonly occupy spaces with ceilings ranging between twenty and thirty feet in height.
More informationASTACEA4 Inspect complex/central air conditioning systems
Overview This Unit covers the competences required to inspect complex/central air conditioning systems as defined by the CIBSE TM 44 Figure 1.1: Summary of system types and their component parts. The air
More informationSECTION 23 05 93 TESTING, ADJUSTING, AND BALANCING FOR HVAC INTRODUCTORY INFORMATION
SECTION 23 05 93 TESTING, ADJUSTING, AND BALANCING FOR HVAC INTRODUCTORY INFORMATION The purpose of this guide specification is to assist the specifier in correctly specifying Mechanical System Testing
More informationDevelopment of Ventilation Strategy in Diesel Engine Power Plant by Using CFD Modelling
Development of Ventilation Strategy in Diesel Engine Power Plant by Using CFD Modelling Panu Mustakallio and Risto Kosonen Halton Oy, Haltonintie 1-3, 47400 Kausala, Finland E-mail: panu.mustakallio@halton.com
More informationSpetec. Laminar Flow Box. Portable Clean Room Technology
Spetec Laminar Flow Box Portable Clean Room Technology 1 Fundamentals Portable Clean Room Technology Laminar Flow The basis for the development of the clean room technology was first established in the
More informationHERZ-Thermal Actuators
HERZ-Thermal Actuators Data Sheet 7708-7990, Issue 1011 Dimensions in mm 1 7710 00 1 7710 01 1 7711 18 1 7710 80 1 7710 81 1 7711 80 1 7711 81 1 7990 00 1 7980 00 1 7708 11 1 7708 10 1 7708 23 1 7709 01
More informationQuality alu LED profiles
Quality alu LED LED PROFILES - PRODCUT CATALOGUE 2010 Quality Aluminum LED Manufacturer & Designer NEW RECESSED SLIM LINE 15mm Introduction: It is recessed type of the aluminum LED profile to build into
More informationFederation of European Heating, Ventilation and Air-conditioning Associations
Federation of European Heating, Ventilation and Air-conditioning Associations Address: Rue Washington 40 1050 Brussels Belgium www.rehva.eu info@rehva.eu Tel: +32 2 514 11 71 Fax: +32 2 512 90 62 Use of
More informationHVAC Characteristics. Test Space HVAC Characteristics
HVAC Characteristics Information on the characteristics of the heating, ventilation, and air conditioning (HVAC) system(s) in the entire BASE building including types of ventilation, equipment configurations,
More informationReplacement of Heating, Ventilation, Air Conditioning (HVAC) Units In Apartments Located at 641 Fifth Avenue. Photo Essay
Original HVAC Units: Replacement of Heating, Ventilation, Air Conditioning (HVAC) Units In Apartments Located at 641 Fifth Avenue Photo Essay One fan motor draws air from the lower section of the unit,
More informationIn-Line Air Separators
Air Elimination & Control In-Line Air Separators The AC models of air separators deliver all the quality and performance you expect from Taco products. They are built to last with shell, heads and ANSI
More informationRPV - RP - RA air handling units
APPLICATIONS Heating, ventilation, cooling >> FACTORIES >> WAREHOUSES >> HALLS >> DISTRIBUTION CENTRES >> COMMERCIAL PREMISES >> PLACES OF WORSHIP RPV - RP - RA air handling units www.reznor.eu RPV - RP
More informationsystemair Smoke Extract Fans Keep Your Cool: Smoke Extraction with Systemair
Fans Air Handling Units Air Distribution Products Fire Safety Air Curtains and Heating Products Tunnel Fans Smoke Extract Fans Keep Your Cool: Smoke Extraction with Systemair systemair Disclose the secret
More informationUNIVERSITY OF MISSOURI 23 0000 - Heating Ventilating and Air-Conditioning (HVAC) March 2015.01
GENERAL: This section provides general standards for overall sizing and design of Heating, Ventilating, and Air Conditioning (HVAC) systems. Other sections contain specific standards for each system per
More informationTailor Made Perforation
Tailor Made Perforation As the world s largest manufacturer and supplier of perforated metal, RMIG can not only provide you with every type of perforated product you could ever want, but can also work
More informationEFA PSBP. Natural Ventilation Strategy. Introduction. 1.1 Relevant legislation. 1.1.1 The Building Regulations 2010
EFA PSBP Natural Ventilation Strategy Introduction The Baseline Designs Project will provide scheme design details for a number of Primary and Secondary School Exemplars. For the purposes of setting a
More informationAIR DISTRIBUTION FOR COMFORT AND IAQ
AIR DISTRIBUTION FOR COMFORT AND IAQ Heating Piping and Air Conditioning March 1998 Dan Int-Hout Chief Engineer KRUEGER EXCELLENCE IN AIR DISTRIBUTION Modern environmentally controlled spaces consume significant
More informationHVAC Code Requirements
one and two family dwellings? Answer: SECTION 2001: GENERAL 2001.1 Air supply. Fuel-burning equipment shall be provided with a supply of air for fuel combustion, draft hood dilution and ventilation of
More informationModular Access Floor for Data Center. From Rack to Row to Room to Building
Modular Access Floor for Data Center From Rack to Row to Room to Building Why using Scneider Electric modular access floor in Data Centers The evolution of modern Data Centers emphasizes specific exigencies
More informationFläkt Woods Building Future
Energy, Expertise and Environment with Fläkt Woods Fläkt Woods Building Future Saving energy in building ventilation You must save 20% on energy before 2020. Following the Kyoto protocol the European Union
More informationNEW CEILING MODULE DS-W1 WAVE : SUBSTANTIALLY HIGHER CAPACITY AND ENERGY EFFICIENCY
NEW CEILING MODULE DS-W1 WAVE : SUBSTANTIALLY HIGHER CAPACITY AND ENERGY EFFICIENCY With the groundbreaking new heating and cooling module DS-W1 Wave, compared to conventional radiant solutions, the heating
More informationSupply air diffuser ROKA/RPKA
Supply air diffuser ROKA/RPKA The ROKA and RPKA are supply air diffusers designed for ceiling mounting. Diffuser ROKA has an unperforated diffuser plate and RPKA has a perforated diffuser plate. The diffusers
More informationRadiant Panels and Chilled Sails. www.price-hvac.com
Radiant Panels and Chilled Sails www.price-hvac.com Radiant Panels and Chilled Sails Introduction Radiant panels use thermal radiation to modify surface temperatures in order to provide sensible cooling
More informationDisplacement ventilation
General The displacement ventilation principle is the oldest form of ventilation and can be achieved without the use of fans. Air movement occurs by means of the density differences between supply air
More information- White Paper - Data Centre Cooling. Best Practice
- White Paper - Data Centre Cooling Best Practice Release 2, April 2008 Contents INTRODUCTION... 3 1. AIR FLOW LEAKAGE... 3 2. PERFORATED TILES: NUMBER AND OPENING FACTOR... 4 3. PERFORATED TILES: WITH
More informationCRAC Precision climate control units for data centres
CRAC Precision climate control units for data centres 2 Rittal Computer Room Air Conditioner The whole is more than the sum of its parts The same is true of Rittal The System. With this in mind, we have
More informationInnovent LASER Packaged Fresh Air Conditioning Units
LASER Latent And Sensible Energy Reduction Latent And Sensible Energy Reduction For Outside Air Innovent LASER Packaged Fresh Air Conditioning Units Innovent LASER units provide both sensible and latent
More informationFundamentals of Acoustics & Practical HVAC Design Considerations. Demir Doken Acoustic Engineer
Fundamentals of Acoustics & Practical HVAC Design Considerations Demir Doken Acoustic Engineer What is sound? Sound is a mechanical wave that is an oscillation of pressure transmitted through some medium
More informationData Center Design Guide featuring Water-Side Economizer Solutions. with Dynamic Economizer Cooling
Data Center Design Guide featuring Water-Side Economizer Solutions with Dynamic Economizer Cooling Presenter: Jason Koo, P.Eng Sr. Field Applications Engineer STULZ Air Technology Systems jkoo@stulz ats.com
More informationCFD Grows Up! Martin W. Liddament Ventilation, Energy and Environmental Technology (VEETECH Ltd) What is Computational Fluid Dynamics?
CIBSE/ASHRAE Meeting CFD Grows Up! Martin W. Liddament Ventilation, Energy and Environmental Technology (VEETECH Ltd) 10 th December 2003 What is Computational Fluid Dynamics? CFD is a numerical means
More informationEnergy Efficient HVAC-system and Building Design
Energy Efficient HVAC-system and Building Design Maija Virta 1, Harri Itkonen 1, Panu Mustakallio 1, Risto Kosonen 1 1 Halton Oy, Finland Corresponding email: maija.virta@halton.com SUMMARY This paper
More informationUNDERFLOOR AIR DISTRIBUTION
FINAL REPORT NCEMBT-080801 UNDERFLOOR AIR DISTRIBUTION AN EXPERIMENTAL COMPARISON OF AIR DIFFUSION PERFORMANCE BETWEEN UNDERFLOOR AIR DISTRIBUTION AND CONVENTIONAL OVERHEAD AIR DISTRIBUTION SYSTEMS AUGUST
More informationBring the fresh in. Dedicated Outside Air Systems
Bring the fresh in. Dedicated Outside Air Systems The inside story on outside air. On average, we breathe in 3,400 gallons of air each day. Ambient indoor air pollution is a major problem, affecting health
More informationResearch Project F 2071. W. Richter. Manual of thermal comfort of Summer cooling mode
Research Project F 2071 W. Richter Manual of thermal comfort of Summer cooling mode Dortmund/Berlin/Dresden 2007 This publication is a summary of the final report of a project Development of a manual on
More informationCOMMERCIAL COOKING HOODS, VENTILATION & FIRE SUPPRESSION SYSTEM GUIDELINES AND PROCEDURES
COMMERCIAL COOKING HOODS, VENTILATION & FIRE SUPPRESSION SYSTEM GUIDELINES AND PROCEDURES These guidelines are to be used for ALL commercial cooking hoods, ventilation systems and related fire suppression
More informationUDSA - UDSBD unit heater
APPLICATIONS Heating >> FACTORIES >> WAREHOUSES >> HALLS >> SHOWROOMS >> GREENHOUSES >> RETAIL >>... UDSA - UDSBD unit heater www.reznor.eu V3 gas fired unit heater Reznor V3 unit heaters are one of the
More informationAir Conditioning. The opportunity for energy efficiency. Low cost actions to reduce energy usage now
Fact Sheet #6 Air Conditioning In this fact sheet you will discover: The opportunity for energy efficiency How air conditioning works Low cost actions to reduce energy usage now Investments to reduce costs
More informationIEQ-15 Air Distribution System
AIM OF CREDIT To encourage and recognise the design and maintenance of air distribution systems that minimise the risk of particulate and microbial contamination to the internal air supply. CREDIT CRITERIA
More informationCFD MODELLING FOR SWIRL DIFFUSER AND ITS IMPLICATIONS ON AIR CHANGE EFFECTIVENESS ASSESSMENT TO GREEN STAR'S IEQ-2
CFD MODELLING FOR SWIRL DIFFUSER AND ITS IMPLICATIONS ON AIR CHANGE EFFECTIVENESS ASSESSMENT TO GREEN STAR'S IEQ-2 Eddy Rusly 1 and Mirek Piechowski 2 1,2 Meinhardt (VIC), Melbourne, Australia ABSTRACT
More informationLiebert Hiross HPW The High Performance Wallmount Cooling Solutions for Telecom Mobile Remote Access Nodes
Precision Cooling for Business-Critical Continuity Liebert Hiross HPW The High Performance Wallmount Cooling Solutions for Telecom Mobile Remote Access Nodes We re Emerson Network Power, backed by Emerson,
More informationPFT Two stage axial fan The high pressure fan for modern boiler plants
PFT Two stage axial fan The high pressure fan for modern boiler plants Modern boilers equipped with complete flue-gas cleaning systems demand fans for high pressure that can be controlled quickly and accurately
More informationCOMPARISON OF THE THERMAL ENVIRONMENT IN ROOMS WITH CHILLED BEAM AND RADIANT PANEL SYSTEMS
COMPARISON OF THE THERMAL ENVIRONMENT IN ROOMS WITH CHILLED BEAM AND RADIANT PANEL SYSTEMS Risto Kosonen, Panu Mustakallio Arsen Melikov 2, Marcin Duszyk 2 Oy Halton Group Ltd., Helsinki, Finland. 2 International
More informationCleanroom systems. HVAC systems for hospitals
Cleanroom systems HVAC systems for hospitals Let us explore together the different building areas Pages 4 5 Reception / Waiting area Pages 6 9 Best air management solutions through customized systems KRANTZ
More informationSERVER ROOM CABINET INSTALLATION CONCEPTS
SERVER ROOM CABINET INSTALLATION CONCEPTS SERVER ROOM CABINET INSTALLATION CONCEPTS SERVER ROOM CABINET INSTALLATION CONCEPTS ZPAS 169 EXAMPLES OF SERVER ROOMS PROJECTS WITH ZPAS CABINETS Data Box in the
More informationplenum slot diffusers
light powered Redefine your comfort zone. www.titus-hvac.com dual-function smart logic light powered energy solutions Table of Contents PLENUM SLOT IFFUSERS products Plenum Slot iffusers Products... 4
More information1. Certification: Employ an ASCS certified by NADCA on a full-time basis. 2. Supervisor Qualifications: Certified as an ASCS by NADCA.
PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply to this Section.
More informationSMALL DUCT HIGH VELOCITY COMFORT SYSTEM
SMALL DUCT HIGH VELOCITY COMFORT SYSTEM N e w C o n s t r u c t i o n R E N O V A t i o N S C u s t o m H o m e s The attractive, effective solution for keeping your home comfortable... Comfort depends
More informationCable Trays Technical Instructions & Specifications
Cable Trays Technical Instructions & Specifications Products Catalogue Objective and Structure The company s main objective is the supply of quality products, with respect to: practical design increased
More information19" Data Racks. Adjustable feet To compensate for uneven floors and assure great stability all feet can be up to 20 mm adjusted.
19" Data Racks Attractive design and high quality are characteristic. Basic framework is welded from multiple bent metal plate, which assures great rigidity suitable for heavier equipment. All profile
More informationSECTION 23 00 01 HEATING, VENTILATION AND AIR CONDITIONING EQUIPMENT
SECTION 23 00 01 HEATING, VENTILATION AND AIR CONDITIONING EQUIPMENT PART 1 - GENERAL 1.1 DESCRIPTION A. The Work specified in this Section consists of designing, furnishing and installing factory-assembled
More informationInternational Telecommunication Union SERIES L: CONSTRUCTION, INSTALLATION AND PROTECTION OF TELECOMMUNICATION CABLES IN PUBLIC NETWORKS
International Telecommunication Union ITU-T TELECOMMUNICATION STANDARDIZATION SECTOR OF ITU Technical Paper (13 December 2013) SERIES L: CONSTRUCTION, INSTALLATION AND PROTECTION OF TELECOMMUNICATION CABLES
More informationSECTION 23 01 30.51 HVAC AIR-DISTRIBUTION SYSTEM CLEANING
SECTION 23 01 30.51 HVAC AIR-DISTRIBUTION PART 1 - GENERAL 1.1 SUMMARY A. Section includes cleaning of interior surfaces of HVAC equipment. The HVAC equipment cleaning work includes the following: 1. Air
More informationDucted air-conditioning gets personal. BY ADVANTAGE AIR
Ducted air-conditioning gets personal. BY ADVANTAGE AIR The philosophy behind MyAir is control; control of comfort and control of energy usage. Comfortable with technology. Advantage Air has long had a
More informationConfort 26. Sliding Systems. Sapa Building System
Confort 26 Sliding Systems Sapa Building System Confort 26 is Sapa s thermally insulated sliding system for windows and doors. Available as two- and three-rail solution. Among its features, there are
More informationby knürr CoolTherm Server cabinet technology with outstanding benefits up to 35kW cooling capacity Blade-Server server optimized! www.knuerr.
HIGH DENSITY COOLING SOLUTIONS by knürr CoolTherm Server cabinet technology with outstanding benefits up to 35kW cooling capacity Blade-Server server optimized! optimiert! Setting benchmarks. Being the
More informationFederation of European Heating, Ventilation and Air-conditioning Associations
Federation of European Heating, Ventilation and Air-conditioning Associations Address: Rue Washington 40 1050 Brussels Belgium www.rehva.eu info@rehva.eu Tel: +32 2 514 11 71 Fax: +32 2 512 90 62 Use of
More informationHVAC Systems and Indoor Air Quality. Douglas K. Spratt, M.Sc., P.Eng.
HVAC Systems and Indoor Air Quality Douglas K. Spratt, M.Sc., P.Eng. The 5 Senses Architecture Electrical Structural Mechanical Hearing Seeing Smelling Feeling Tasting HVAC Systems are Dynamic Heat Gains
More informationT 3 Series VAV Diffusers Analog Diffuser Steel Square Panel Horizontal Pattern Model: T 3 SQ
TSQ--0 7-7-07 T Series VAV Diffusers Analog Diffuser Steel Square Panel Horizontal Pattern Model: T SQ Model Configuration T SQ- Heating / Cooling Border Type (Lay-In) Full Face Nominal Round Duct Size
More informationThis permit does not include replacement or upgrading of the existing electrical panel or service (a separate electrical permit must be obtained).
CITY OF MILPITAS Building & Safety Department 455 E. Calaveras Blvd. Milpitas, CA 95035 408-586-3240 www.ci.milpitas.ca.gov RESIDENTIAL AIR CONDITIONING, REPLACEMENT 1. PERMIT INFORMATION: The replacement
More informationHIGH EFFICIENCY RTU. www.reznorhvac.com HIGH EFFICIENCY, PACKAGED SPACE CONDITIONING. DX System IEER> 13.2 Gas Heat Efficiency > 92% Capacities Tons
Capacities 10-25 Tons 100-400 MBH HIGH EFFICIENCY, PACKAGED SPACE CONDITIONING DX System IEER> 13.2 Gas Heat Efficiency > 92% HIGH EFFICIENCY RTU 30-120 kw 3,000-11,550 CFM Comfort Comfort is determined
More informationSECTION 15936 AIR INLETS AND OUTLETS
SECTION 15936 AIR INLETS AND OUTLETS PART 1 - GENERAL 1.01 SUMMARY A. Section Includes: 1. Diffusers. 2. Registers. 3. Grilles. 4. Louvers. 5. Lowered Penthouses. 6. Gravity Roof Hoods. 7. Gravity Roof
More informationMERO Floor Systems - CleanRoom
MERO Floor Systems - CleanRoom Innovative solutions out of one hand Development Access floor Consulting Hollow floor Planning Floor covering and Manufacturing Installation Installation Services Floor systems
More informationWound Rotor Induction Motors 4-12 poles, up to 8000 kw, 11500 HP
Wound Rotor Induction Motors 4-12 poles, up to 8000 kw, 11500 HP ABB The Preferred Partner Egypt Cement Corporation, a major cement manufacturer, has chosen ABB wound rotor motors for all key applications
More informationUsing waste heat. with gas-fired steam humidifiers Condair GS. Humidification and evaporative cooling
Using waste heat with gas-fired steam humidifiers Condair GS Humidification and evaporative cooling Economical and ecological steam production with gas as primary energy. Gas-operated steam humidification
More informationNON-DESTRUCTIVE TESTING OF PIPELINES. L. Annila. Abstract
NON-DESTRUCTIVE TESTING OF PIPELINES L. Annila Abstract This paper shall present different, contemporarily available non-destructive testing (NDT) methods of pipelines and compare them to each other from
More informationAll the best brands all under one roof
All the best brands all under one roof Year round comfort and energy efficiency The air conditioner you choose today is going to be with you for a long time, so it s important to choose wisely. The best
More informationGuidelines for energy efficient heating, ventilation and air conditioning (HVAC) systems
Guidelines for energy efficient heating, ventilation and air conditioning (HVAC) systems If you're a designer or a BCA, this guidance on the energy efficiency of HVAC systems in commercial buildings may
More informationCFD ANALYSIS CHALLENGES IN BUILDING SIMULATION FOR SIMBUILD2004 CONFERENCE. Ferdinand Schmid and Galen Burrell Architectural Energy Corporation
CFD ANALYSIS CHALLENGES IN BUILDING SIMULATION FOR SIMBUILD2004 CONFERENCE Ferdinand Schmid and Galen Burrell Architectural Energy Corporation ABSTRACT This paper discusses the capabilities and challenges
More informationStylish Integration of Linear Diffusers With system solutions and installation details for architects and interior designers
Stylish Integration of Linear Diffusers With system solutions and installation details for architects and interior designers Foto Museum Frie der Burda Types Integrate diffusers unobtrusively in flush,
More informationThe A-Z of ducted AC.
The A-Z of ducted AC. (or how ducted air-conditioning works) Understanding air-conditioning When most people think air-conditioning, they think about the outdoor unit or compressor. While that is the component
More informationSubpart 1. Installation. All plumbing systems must be. installed and tested according to this chapter and chapter 4715,
4658.4500 PLUMBING SYSTEMS; NEW CONSTRUCTION. Subpart 1. Installation. All plumbing systems must be installed and tested according to this chapter and chapter 4715, the Minnesota Plumbing Code. Subp. 2.
More information