1 FL1000 Rack-Mount Panel Installation and Operation Guide A FL1000 Rack-Mount Panel (24 Position Terminal Panel Shown) Content Page INTRODUCTION REVISION HISTORY Trademark Information Admonishments PRODUCT DESCRIPTION Options That Affect Installation Accessories Specifications and Dimensions UNPACKING AND INSPECTING THE PRODUCT INSTALLATION Installing a Rack-Mount Chassis Inch Rack, 5-Inch Recess (as Shipped) Inch Rack, Flush; 23-Inch Rack, 5-Inch Recess; 23-Inch Rack, Flush Installing a Pre-Terminated Panel Installing 6pak Adapter Plates and Pigtails Adapter Plates Without Pigtails (Blank or 6Pak) Adapter Plates With Pigtails Installing Cables and Routing Fibers Position Termination Panel Position Termination Panel Termination/Splice Panel (24, 36, 72, 96, or 144 Position) (continued) Rev A Page 1

2 Content Page 3.4 Splicing OPERATION Installing Patch Cords Cleaning Adapters and Connectors CUSTOMER INFORMATION AND ASSISTANCE INTRODUCTION ADC FL1000 rack-mount panels provide solutions for terminating and splicing fibers in small fiber networks. The product line includes 12 and 24 position termination panels, and 24, 36, 48, 72, 96, and 144 position termination/splice panels. This manual contains all procedures required to install and operate any FL1000 rack-mount panel or product option. REVISION HISTORY quad cables and patch cord routing ISSUE DATE REASON FOR CHANGE Issue 1 04/2003 Original. Issue 2 09/2006 Added 36, 48, 72, 96, and 144 position termination/splice panels; updated figures for 24 position termination/splice panel to show greater height (than previous model); added figure for drawer removal. Trademark Information ADC is a registered trademark of ADC Telecommunications, Inc. FL1000 is a trademark of ADC Telecommunications, Inc. ST is a registered trademark of AT&T Technologies, Inc. Admonishments Important safety admonishments are used throughout this manual to warn of possible hazards to persons or equipment. An admonishment identifies a possible hazard and then explains what may happen if the hazard is not avoided. The admonishments in the form of Dangers, Warnings, and Cautions must be followed at all times. These warnings are flagged by use of the triangular alert icon (seen below), and are listed in descending order of severity of injury or damage and likelihood of occurrence. Danger: Danger is used to indicate the presence of a hazard that will cause severe personal injury, death, or substantial property damage if the hazard is not avoided. Warning: Warning is used to indicate the presence of a hazard that can cause severe personal injury, death, or substantial property damage if the hazard is not avoided. Page 2

3 Caution: Caution is used to indicate the presence of a hazard that will or can cause minor personal injury or property damage if the hazard is not avoided. 1 PRODUCT DESCRIPTION The FL1000 rack-mount panel is a compact, efficient fiber optic panel designed for low count fiber applications. It is available in eight types: 12 or 24 position termination panel; 24, 36, 48, 72, 96, or 144 position termination/splice panel. All eight types can be installed on either a 19-inch (48.26 cm) or 23-inch (58.42 cm) EIA or WECO rack. They can be mounted flush on the rack or with a 5-inch (12.7 cm) recess. Standard flush mount capability makes the panels well-suited to cabinet installations. The eight FL1000 rack-mount models have analogous features. All have angled adapters designed to reduce bend when routing patch cords. All use ADC adapter 6paks. Termination/splice panels are identical to the 24 position termination panel in termination function and, in addition, have a slideout deck used for mounting splice trays. All panel types are designed for patch cords to be connected to the front adapters to patch between optic circuits. FL1000 panels can be used for either a single mode or multimode application. The panel can be used for either Outside Plant (OSP) or Intra Facility Cable (IFC). Figure 1 shows the main external features of the 12 position termination panel with its bulkhead and two 6pak adapter plates. This panel has a removable front access door providing access to the front side of the bulkhead. A slide-out deck provides access to the cable subunits routed through the chassis to the rear adapters. The panel has mounting brackets for fastening the panel to a rack and a cable tie down bracket for securing a cable. TIE LANCE CABLE TIE DOWN BRACKET 6 PACK ADAPTER PLATE (OPTIONAL WITH OR WITHOUT PIGTAILS) A MOUNTING BRACKET FRONT ACCESS DOOR BULKHEAD SLIDE-OUT TRAY Figure 1. Main External Features, 12 Position Termination Panel Page 3

4 Figure 2 shows the main external features of the 24 position termination panel. Like the 12 position panel, it has a removable front access door. In place of a slide-out tray, it has a removable rear cover that provides access to the rear side of the adapters. This panel also has a bulkhead for mounting 6pak adapter plates and mounting brackets for fastening the panel to a rack. REAR COVER (HINGED) A FRONT ACCESS DOOR (HINGED) BULKHEAD 6 PAK ADAPTER PLATE (OPTIONAL WITH OR WITHOUT PIGTAILS) MOUNTING BRACKET Figure 2. Main External Features, 24 Position Termination Panel Figure 3 shows the main external features of the 24 position termination/splice panel. This panel has the same features as the 24 position termination panel plus a slide-out deck for mounting splice trays. The slide-out deck is located below the bulkhead. The slide-out deck holds up to four standard 12 position splice trays. Internal pigtails are used to transition between the spliced fibers and the rear side of the adapters. The 36, 48, 72, 96, and 144 position termination/splice panels have analogous features to the 24 position panel. 1.1 Options That Affect Installation The panels may be ordered in any of the following configurations. Without 6paks With 6paks pre-installed into panel With 6paks pre-installed and attached to IFC/OSP cable (termination panel only) With 6paks pre-installed and attached to pigtails (termination/splice panel only) With 6paks shipped separately With 6paks shipped separately and attached to pigtails With or without splice trays (termination/splice panel only) Page 4

5 BULKHEAD HINGED REAR COVER SPLICE TRAY (OPTIONAL) B SLIDE-OUT DECK FRONT ACCESS DOOR RADIUS LIMITER (4 PLACES) 6 PAK ADAPTER PLATE (OPTIONAL WITH OR WITHOUT PIGTAILS) MOUNTING BRACKET Figure 3. Main External Features, 24 Position Termination/Splice Panel 1.2 Accessories The following accessories are available for use with FL1000 rack-mount panels: Cable Clamp Kits Contain a clamp and the hardware required for securing an IFC or OSP cable to the rear side of the panel. Cable clamp kits are available for all panel types except 12 position termination. Bonding Grounding Kit Contains the components required to ground an OSP cable. Radius Limiters Can be installed on the rack to provide a vertical duct for holding patch cords. 6Pak Adapter Plates Each contain six adapters designed to be mounted in a mounting slot in the bulkhead. For connector types, refer to Subsection 1.3. Splice Trays may be ordered in any of the standard types, including bare fusion, heat shrink, mechanical, rotary, FibrLok, Nortel QPAK, and AFL. Page 5

6 1.3 Specifications and Dimensions Table 1 provides specifications for the FL1000 rack-mount panels. PARAMETER Table 1. Specifications for FL1000 Rack-Mount Panels SPECIFICATION Environment Temperature Operating 40 C to 65 C ( 40 F to149 F) Storage 55 C to 85 C ( 85 F to185 F) Relative Humidity Operating Up to 80% (no condensation) Storage Up to 95% (no condensation) 12 Position Termination Panel Number of Terminations 12 Dimensions (H x W x D) 1.73 x x in. (4.39 x x cm) 24 Position Termination Panel Number of Terminations 24 Dimensions (H x W x D) 3.46 x x in. (8.79 x x cm) 24 Position Termination/Splice Panel 3RU Number of Terminations/Splices 24 Dimensions (H x W x D) 5.23 x x in. (13.28 x x cm) 24 Position Termination/Splice Panel 4RU Number of Terminations/Splices 24 Dimensions (H x W x D) 7.00 x x in. (17.78 x x cm) 36 Position Termination/Splice Panel Number of Terminations/Splices 36 Dimensions (H x W x D) 7.00 x x in. (17.78 x x cm) 48 Position Termination/Splice Panel Number of Terminations/Splices 48 Dimensions (H x W x D) 8.75 x x in. (22.23 x x cm) 72 Position Termination/Splice Panel Number of Terminations/Splices 72 Page 6

7 Table 1. Specifications for FL1000 Rack-Mount Panels PARAMETER SPECIFICATION Dimensions (H x W x D) x x in. (31.12 x x cm) 96 Position Termination/Splice Panel Number of Terminations/Splices 96 Dimensions (H x W x D) x x in. (40.01 x x cm) 144 Position Termination/Splice Panel Number of Terminations/Splices 144 Dimensions (H x W x D) x x in. (57.79 x x cm) Adapter Packs ADC 6pak adapter plates Connector Type Available in most standard types including multimode SC, duplex SC, ST, or FC; singlemode PCSC, duplex PCSC, PCST, PCFC, PCST-Zirconia, PCSC-Zirconia, PCFC-Zirconia, 8 SC/APC, 8 FC/APC, 8 E-2000/ APC, LC, and LX.5 Splice Trays (When Present) Bare fusion, heat shrink, mechanical, rotary, FibrLok, Nortel QPAK, and AFL Figure 4 shows the dimensions for a 12 position termination panel. Figure 5 shows a 24 position termination panel. Figure 6 shows a 24 position termination/splice panel. Page 7

8 17.0 IN. (43.18 CM) 12.0 IN. (30.48 CM) TOP VIEW 1.73 IN. (4.39 CM) FRONT VIEW A Figure Position Termination Panel Dimensions 17.0 IN. (43.18 CM) 12.0 IN. (30.48 CM) TOP VIEW 3.46 IN. (8.79 CM) FRONT VIEW A Figure Position Termination Panel Dimensions Page 8

9 17.0 IN. (43.18 CM) IN. (31.39 CM) TOP VIEW 5.23 IN. (13.28 CM) FRONT VIEW A Figure Position Termination/Splice Panel Dimensions (3RU Model Shown) 2 UNPACKING AND INSPECTING THE PRODUCT Use the following procedure to unpack and inspect the FL1000 panel: 1. Inspect the exterior of the shipping container for evidence of rough handling that may have damaged the contents of the container. 2. Unpack the panel and inspect for possible damage. 3. If damage is detected or if parts are missing, file a claim with the commercial carrier and then notify ADC Customer Service. Save damaged carton for inspection by carrier. 4. Refer to Section 5 of this publication for repair, replacement, and warranty information. 5. Even if no damage is evident, save the shipping container in case the equipment requires shipment at a future date. Page 9

10 3 INSTALLATION 3.1 Installing a Rack-Mount Chassis The FL1000 rack-mount panel can be installed on either a 19-inch (48.26 cm) or 23-inch (58.42 cm) rack. It is designed for mounting in an EIA style rack, but a WECO style rack can also be used. It can be mounted flush on the rack or with a 5-inch (12.7 cm) recess. The panel is shipped ready to be installed with a 5-inch recess on a 19-inch rack. For other mounting positions, the mounting brackets must be removed and remounted in a different orientation. Select from the procedures below based on your specific installation Inch Rack, 5-Inch Recess (as Shipped) See Figure 7. Use the following procedure. 1. Position the chassis on the rack. 2. Attach the mounting brackets to the rack using the #12-24 screws supplied. MOUNTING BRACKET POSITIONED FOR 5-INCH RECESS MOVE MOUNTING BRACKETS TO THIS POSITION FOR FLUSH MOUNT A Figure 7. Installing a Chassis on a 19-Inch Rack Page 10

11 Inch Rack, Flush; 23-Inch Rack, 5-Inch Recess; 23-Inch Rack, Flush For these positions, the mounting brackets must be removed and remounted in a different orientation. Use the following procedure. 1. Remove the mounting brackets. 2. Remount the mounting brackets in the position shown: a. For 19-inch rack, flush mount, use Figure 7 forward position; b. For 23-inch rack, 5-inch recess mount, use Figure 8 back position; c. For 23-inch rack, flush mount, use Figure 8 forward position. 3. Attach the mounting brackets to the rack using the #12-24 screws supplied. MOUNTING BRACKET POSITIONED FOR 5-INCH RECESS MOVE MOUNTING BRACKETS TO THIS POSITION FOR FLUSH MOUNT A Figure 8. Installing a Chassis on a 23-Inch Rack Page 11

12 3.1.3 Installing a Pre-Terminated Panel Per customer order, some FL1000 rack mount panels are shipped pre-terminated to an IFC or OSP cable and attached to a cable spool. When installing a pre-terminated panel, unwind the cable roll or spool from the top of the panel and set it close to the rack on the floor, then install the panel chassis as described in the Subsection and Subsection Installing 6pak Adapter Plates and Pigtails The 6pak adapter plates may be any of several types including: Simplex or duplex with adapters only Simplex or duplex with adapters and attached pigtails To install adapter plates without pigtails, refer to the first procedure below. To install adapter plates with pigtails, refer to the second procedure. Adapter plates with pigtails are used in the 24 position termination/splice panel only Adapter Plates Without Pigtails (Blank or 6Pak) Use the following procedure to install blanks or 6pak plates without pigtails: 1. Remove the front access cover. 2. Align the adapter plate tabs with the notches in the mounting slot as shown in Figure 9 (with the letters ADC and two end tabs facing out). SLOT SPLICE DECK END TAB 6 PAK PLATE (LOADED) B Figure 9. Installing 6pak Plates Page 12

13 3. Slide the 6pak adapter plate or blank into the slot until it snaps in place Adapter Plates With Pigtails Use this procedure to install 6pak plates with pigtails in a termination/splice panel. 1. Remove the front access cover and slide out the splice deck. 2. Thread the pigtails through the empty mounting slot and loop the pigtails around the radius limiters in the chassis as shown in Figure 10 for the 24 position panel. END TAB SLOT 6 PAK PLATE (LOADED) C SPLICE DECK PIGTAILS RADIUS LIMITER (4 PLACES) Figure 10. Installing 6pak Plates with Pigtails (24 Position Panel Shown) 3. Align the adapter plate tabs with the notches in the mounting slot as shown in Figure 10 (with the letters ADC and two end tabs facing out). 4. Slide the 6pak plate into the slot until it snaps in place. 5. Fan out the fibers and route them as shown in Figure 11. Position the fanning chip as shown and tie it down using cord lacing. 6. Route the fibers to the splice tray. For an illustration of correct routing, refer to Subsection 3.4, below. Page 13

14 TIE DOWN USING CORD LACING TOP VIEW WITH SPLICE DRAWER CLOSED PROPER BEND RADIUS MUST BE MAINTAINED TIE DOWN USING CORD LACING A TOP VIEW WITH SPLICE DRAWER OPEN Figure 11. Correct Pigtail Routing Within 24 Position Termination/Splice Panel Page 14

15 3.3 Installing Cables and Routing Fibers The FL1000 rack-mount panel can accommodate either IFC or OSP cable. The procedures used to install the cable differ slightly for the different chassis types. Refer to the appropriate topic below for the type being installed Position Termination Panel Figure 12 shows cable routing options and breakout dimensions for the 12 position termination panel. The cable can enter from above or below the chassis and from the left or right side. Use the following procedure to install the cable. 1. Route the cable to the chassis and break out the cable corresponding to Figure Secure the cable as follows: a. Fasten the tie-down bracket to the panel at the cable point of entry using the screws provided. b. Position the cable on the tie down bracket with the cable sheath extending about 0.75 inch (1.9 cm) beyond the bracket into the chassis. c. Tie down the cable using cord lacing. d. Secure the cable in a second location on the rack or wall using a user-provided clamp per local practice. 3. Remove the front access door and slide out the bulkhead deck. 4. Route the buffers within the chassis from the cable point of entry to the opposite side of the bulkhead deck, as shown in Figure Tie down the buffers in the location shown in Figure 12 using cord lacing secured to the lance. 6. At the buffer breakout point, fan out the fibers from the buffers and secure them using a curly lock at the location shown in Figure 12. Danger: Infrared radiation is invisible and can seriously damage the retina of the eye. Do not look into the optical bulkhead of an operational transmitter, or into the launching (output) end of an active fiber. A clean, protective cap or hood MUST be immediately placed over any radiating bulkhead receptacle or optical fiber connector to avoid exposure to potentially dangerous amounts of radiation. This practice also helps prevent contamination of connectors and adapters. 7. Connect the fiber connectors to the adapters on the rear of the 6pak adapter plate. 8. Slide in the bulkhead deck to its closed position. 9. Replace the front access cover. Page 15

16 Figure 12. Cable Breakout for 12 Position Termination Panel Page 16

17 Position Termination Panel Figure 13 shows cable routing options and breakout dimensions for the 24 position termination panel. The cable can enter from above or below the chassis and from left or right side. Figure 13. Cable Breakout for 24 Position Termination Panel Use the following procedure to install a cable in the 24 position termination panel. 1. Route the cable to the chassis and break out the cable corresponding to Figure Secure the cable as follows (see Figure 14): a. Install the clamp bracket at the chosen clamp location by inserting the two integral bolts from inside the chassis. Page 17

18 b. Sort through the rubber grommets in the kit and find the one that best fits the cable. If the cable is too small to fit snugly in the smallest grommet, build up the cable with tape of a suitable material per local standards. c. Assemble the cable clamp components on the bracket studs in the order shown in the figure and secure with the two nuts provided. Figure 14. Installing a Cable Clamp on a 24 Position Panel (Select from Four Mounting Locations) 3. If the cable being installed is an OSP cable with a metallic strength member, bond the cable to ground following the instructions for the bonding/grounding kit. 4. Remove the rear door, if not already removed. 5. Route the fibers within chassis as shown in Figure 13; tie down fibers in B position shown. Danger: Infrared radiation is invisible and can seriously damage the retina of the eye. Do not look into the optical bulkhead of an operational transmitter, or into the launching (output) end of an active fiber. A clean, protective cap or hood MUST be immediately placed over any radiating bulkhead receptacle or optical fiber connector to avoid exposure to potentially dangerous amounts of radiation. This practice helps prevent contamination of connectors and adapters. Page 18

19 6. Connect the fiber connectors to the adaptors on the rear of the 6pak adapter plate. 7. Replace the rear door Termination/Splice Panel (24, 36, 72, 96, or 144 Position) Figure 16 shows cable routing options and breakout dimensions for the 24 position termination/ splice panel. Routing is analogous for other termination/splice panels. The cable can enter from above or below the chassis and from left or right side. Use the following procedure to install a cable in a termination/splice panel. 1. Route the cable to the chassis. 2. Lift up on the splice drawer and pull it straight out as shown in Figure Thread the cable stub through the chassis onto the splice tray in the approximate position shown in Figure 16. Based on the figure, determine how much length of cable will be required for the B to C double loop section shown. 4. Break out the cable, leaving 36 inches (91.44 cm) of bare fiber for a splicing loop. 5. Secure the cable with a cable clamp in the position shown, about 0.75 inches (1.91 cm) before the breakout point. For instructions refer to Figure 14 on Page Tie the fibers down with cord lacing in the B position shown in Figure If the cable being installed is an OSP cable with a metallic strength member, bond the cable to ground following the instructions for the bonding/grounding kit A PUSH UPWARD AND PULL TO REMOVE DRAWER Figure 15. Removing the Splice Drawer Page 19

20 Figure 16. Fiber Routing in 24 Position Termination/Splice Panel Page 20

21 3.4 Splicing Use the following procedure for splicing in a termination/splice panel. 1. Place a splice tray in the splice drawer (if not already there). 2. Route the fiber into the splice tray on the same side as the pigtail fiber that it is going to be spliced to, as shown in Figure 17. Loop the fiber around twice in the splice tray. 3. Splice per local practice. 4. Tie down the fibers with cord lacing in the C position shown in Figure 17. Refer also to Figure 16 for correct routing. Figure 17. Routing Fibers on a Splice Tray Page 21

22 4 OPERATION In all operation procedures, observe the following precaution. Danger: Infrared radiation is invisible and can seriously damage the retina of the eye. Do not look into the optical bulkhead of an operational transmitter, or into the launching (output) end of an active fiber. A clean, protective cap or hood MUST be immediately placed over any radiating bulkhead receptacle or optical fiber connector to avoid exposure to potentially dangerous amounts of radiation. This practice also helps prevent contamination of connectors and adapters. 4.1 Installing Patch Cords Use the following procedure to install patch cords. 1. Clean all connectors according to local practice. 2. Open the front cover and connect patch cords at the applicable receptacles on the bulkhead panel. 3. Route the patch cords in the direction of the angled adaptor toward the side of the FL1000 unit and then to office equipment (interconnect) or another FL1000 unit (cross-connect). 4. Record the cable fiber identification on the designation label on the front cover. Page 22

23 4.2 Cleaning Adapters and Connectors Dust and other contaminants on fiber optic connectors and adapters can seriously degrade circuit performance. To prevent contamination, each unused connector or adapter must be protected with a clean dust cap. Routine termination activity can also introduce contaminants; therefore, it is essential that connectors and adapters be cleaned before making connections. The cleaning kit available from ADC (catalog number FPC-CLNKIT) can be used to clean any style connector, or any adapters that are accessible from both sides (such as those on the 6pak). Page 23

24 5 CUSTOMER INFORMATION AND ASSISTANCE PHONE: U.S.A. OR CANADA Sales: Extension Technical Assistance: Connectivity Extension Wireless Extension EUROPE Sales Administration: Technical Assistance: EUROPEAN TOLL FREE NUMBERS Germany: UK: Spain: France: Italy: ASIA/PACIFIC Sales Administration: Technical Assistance: ELSEWHERE Sales Administration: Technical Assistance: WRITE: ADC TELECOMMUNICATIONS, INC PO BOX 1101, MINNEAPOLIS, MN , USA ADC TELECOMMUNICATIONS (S'PORE) PTE. LTD. 100 BEACH ROAD, #18-01, SHAW TOWERS. SINGAPORE ADC EUROPEAN CUSTOMER SERVICE, INC BELGICASTRAAT 2, 1930 ZAVENTEM, BELGIUM PRODUCT INFORMATION AND TECHNICAL ASSISTANCE: M Contents herein are current as of the date of publication. ADC reserves the right to change the contents without prior notice. In no event shall ADC be liable for any damages resulting from loss of data, loss of use, or loss of profits and ADC further disclaims any and all liability for indirect, incidental, special, consequential or other similar damages. This disclaimer of liability applies to all products, publications and services during and after the warranty period. This publication may be verified at any time by contacting ADC's Technical Assistance Center. All Rights Reserved Printed in U.S.A Page 24

DDP-3 Engineering Guide

DDP-3 Engineering Guide Issue, May 998 DDP- Engineering Guide Content Page INTRODUCTION... Revision History... List of Changes... Trademark Information... Related Publications... Admonishments.... GERAL... A. Overview of the

More information

Pretium Connector Housings

Pretium Connector Housings Pretium Connector Housings A LANscape Pretium Solutions Product Applications Main cross connect, intermediate cross connects and telecommunications rooms Rack or equipment cabinet installations Data center

More information

4RU High Density Shelf Installation Instructions

4RU High Density Shelf Installation Instructions 4RU High Density Shelf Installation Instructions Table of Contents General Product Information... 1.0 Safety Precautions... 2.0 Tools Required... 3.0 Package Contents... 4.0 Installing the Product Unpacking...

More information

Digital Distribution Point (DDP) 8-Position X-Connect Module User Manual

Digital Distribution Point (DDP) 8-Position X-Connect Module User Manual Digital Distribution Point (DDP) 8-Position X-Connect Module User Manual 18745-A PDDP 8-Position X-Connect Module Content Page ODUCION.............................................................................

More information

Express5800/120Ed. Rack Mount Kit Installation Procedures PN: 455-01607-001

Express5800/120Ed. Rack Mount Kit Installation Procedures PN: 455-01607-001 Express5800/120Ed Rack Mount Kit Installation Procedures PN: 455-01607-001 Proprietary Notice and Liability Disclaimer The information disclosed in this document, including all designs and related materials,

More information

Digital Link Cross Connect (DLx ) System User Manual

Digital Link Cross Connect (DLx ) System User Manual Issue, April 998 Digital Link Cross Connect (DLx ) System User Manual Content Page TRODUCTION... Revision History... Trademark Information... Admonishments... Compliance Statement... Certification... Standards...

More information

How To Install A Power Supply (Uplast) With A Battery Pack

How To Install A Power Supply (Uplast) With A Battery Pack APC Smart-UPS RT SURTA48XLBP/SURTA48XLBPJ External Battery Pack User Manual Introduction/Before Installation About this Manual The APC Smart-UPS RT external battery pack (SURTA48XLBP or SURTA48XLBPJ) connects

More information

1U Multi-Function Fibre Enclosure

1U Multi-Function Fibre Enclosure FEATURES AND SPECIFICATIONS Features and Benefits The is a configurable rack mount unit for storing and terminating incoming fibre cable. The fibre enclosure has been designed to accommodate various termination

More information

Rack installation instructions

Rack installation instructions Rack installation instructions Review the documentation that comes with the rack cabinet for safety and cabling information. Before you install the server in a rack cabinet, review the following guidelines:

More information

HP 16/18-Port Cable Management Kit Installation Guide

HP 16/18-Port Cable Management Kit Installation Guide HP 16/18-Port Cable Management Kit Installation Guide Abstract This document describes how to attach the HP 16 Port or 18 Port Cable Management Kit to an HP rack. The cable management bracket is designed

More information

HP 36-Port InfiniBand Switch Cable Management Kit Installation Guide

HP 36-Port InfiniBand Switch Cable Management Kit Installation Guide HP 36-Port InfiniBand Switch Cable Management Kit Installation Guide HP Part Number: 574412-doc Published: May 2009 Copyright 2009 Hewlett-Packard Development Company, L.P. The information contained herein

More information

Read Me First: Unpacking Express5800/320Fc System Cabinets

Read Me First: Unpacking Express5800/320Fc System Cabinets Read Me First: Unpacking Express5800/320Fc System Cabinets NEC Corporation of America 456-01721-000 Notice The information contained in this document is subject to change without notice. UNLESS EXPRESSLY

More information

FTTX Solutions FDH 3000 Cross-Connect

FTTX Solutions FDH 3000 Cross-Connect TE Connectivity's (TE) FTTX infrastructure solutions are designed from the ground up to meet the unique requirements of FTTX networks. Designed for operational efficiency and scalability, TE s FTTX solutions

More information

Opticom Fiber Optic Splice Module

Opticom Fiber Optic Splice Module Opticom Fiber Optic Splice Module Part Numbers: FOSMF, FOSMM Panduit Corp. 2014 INSTALLATION INSTRUCTIONS FOSMF in open position FOSMM in open position FOSMF OR FOSMM in closed position Contents: (1) SPLICE

More information

Cascade Profiler Fibre Channel SAN Attached Storage Installation Guide. Version 8.2 March 2009

Cascade Profiler Fibre Channel SAN Attached Storage Installation Guide. Version 8.2 March 2009 Cascade Profiler Fibre Channel SAN Attached Storage Installation Guide Version 8.2 March 2009 Trademarks Riverbed, the Riverbed logo, Riverbed Cascade, and Cascade are trademarks of Riverbed Technology,

More information

Unpacking, Installation, and Customization

Unpacking, Installation, and Customization Unpacking, Installation, and Customization NetShelter WX Enclosure AR100 AR100HD Contents Unpacking... 1 How to Unpack the Enclosure............................... 1 Please Recycle..........................................

More information

UPDATEUPDATEUPDATE. Converting the tower chassis to a rack-mount chassis. A - M5 13 8 To mount outer member to rack

UPDATEUPDATEUPDATE. Converting the tower chassis to a rack-mount chassis. A - M5 13 8 To mount outer member to rack UPDATEUPDATEUPDATE Converting the tower chassis to a rack-mount chassis Rail overview Converting your Server to Rack-Mount The rail kit includes the following: Two rail units Five packages of screws (labeled

More information

PS6500 Storage Arrays Rack Mount Instructions

PS6500 Storage Arrays Rack Mount Instructions PS6500 Storage Arrays Rack Mount Instructions Part Number: R724M Rev. A01 Copyright 2010 Dell, Inc. All rights reserved. Dell is a trademark of Dell, Inc. EqualLogic is a registered trademark. All trademarks

More information

HP UPS R1500 Generation 3

HP UPS R1500 Generation 3 HP UPS R1500 Generation 3 Installation Instructions Part Number 650952-001 NOTE: The rating label on the device provides the class (A or B) of the equipment. Class B devices have a Federal Communications

More information

FCS-FCT-FCP Housings and Connector Panels. InfiniCor SX+ OM3, InfiniCor 600 OM2, InfiniCor 300 OM1, SMF 28e OS1/OS2

FCS-FCT-FCP Housings and Connector Panels. InfiniCor SX+ OM3, InfiniCor 600 OM2, InfiniCor 300 OM1, SMF 28e OS1/OS2 Product Family: Product: Fibre: LANscape Hardware Solutions FCS-FCT-FCP Housings and Connector Panels InfiniCor SX+ OM3, InfiniCor 600 OM2, InfiniCor 300 OM1, SMF 28e OS1/OS2 Applications Corning Cable

More information

LANC Fibre Patch Panel Solution

LANC Fibre Patch Panel Solution features and benefits Modular front with interchangeable fibre optic adapter modules Quick mount feature (teardrop design) Port numbers printed above and below adapter modules High-density using LC connectivity

More information

42U/45U 28" Wide Rack Installation & Service Guide

42U/45U 28 Wide Rack Installation & Service Guide 42U/45U 28" Wide Rack Installation & Service Guide 96-00171-005 Rev B Important Information Information in this document is subject to change without notice and does not represent a commitment on the part

More information

Rack Installation Instructions

Rack Installation Instructions Rack Installation Instructions Second Edition (June 2014) 2014 Contents Chapter 1. Safety information..... 1 Chapter 2. Rack kit parts inentory... 3 Chapter 3. Rack installation...... 5 Identifying the

More information

ATS Overhead Table Shelf System INSTRUCTION MANUAL

ATS Overhead Table Shelf System INSTRUCTION MANUAL ATS Overhead Table Shelf System INSTRUCTION MANUAL ATS Overhead Table Shelf System Instruction Manual Warranty Newport Corporation warrants this product to be free of defects in material and workmanship

More information

Wideband Optical Splitters FOS Series

Wideband Optical Splitters FOS Series Wideband Optical Splitters FOS Series Guide to Installation and Operation M949-9100-103 13 Mar 2014 Miranda Technologies 3499 Douglas-B.-Floreani St-Laurent, Québec, Canada H4S 2C6 Tel. 514-333-1772 Fax.

More information

Expanding a 40-Type Cabinet

Expanding a 40-Type Cabinet Expanding a 40-Type Cabinet using the 3M Add-On Terminal 4220P 400-Pair and Jumper Trough Instructions January 2006 Table of Contents 1.0 General... 3 2.0 Cabinet Overall Descriptions... 3 3.0 Tools Required...

More information

Rack Installation Instructions

Rack Installation Instructions Rack Installation Instructions Guidelines This publication provides information about how to install your server into a standard rack cabinet using the rail kit shipped with your server. If you no longer

More information

How To Use The Visifault Visual Fault Locator

How To Use The Visifault Visual Fault Locator VisiFault Visual Fault Locator Instruction Sheet The VisiFault Visual Fault Locator (VFL) is a visible light source that helps you trace optical fibers, check fiber continuity, and find faults such as

More information

Cabinets 101: Configuring A Network Or Server Cabinet

Cabinets 101: Configuring A Network Or Server Cabinet Cabinets 101: Configuring A Network Or Server Cabinet North, South and Central America White Paper May 2012 www.commscope.com Contents Background Information 3 What is a network or server cabinet? 3 What

More information

HP SATA/SAS hard drive and Solid State Drive installation

HP SATA/SAS hard drive and Solid State Drive installation HP SATA/SAS hard drive and Solid State Drive installation This document describes how to install Serial ATA (SATA) and Serial Attached SCSI (SAS) hard drives or Solid State Drives (SSD) in an internal

More information

About the BitStorm 6051 POTS Splitter

About the BitStorm 6051 POTS Splitter BitStorm 6051 Installation Instructions Document Number 6051-A2-GZ40-10 July 2002 About the BitStorm 6051 The BitStorm system enables simultaneous high-speed digital data access and analog voice service

More information

FACT OPTICAL DISTRIBUTION FRAME SYSTEM

FACT OPTICAL DISTRIBUTION FRAME SYSTEM Fiber Connectivity for Splice/Patch and Patch/Patch For almost 30 years, CommScope has led the industry with solutions such as FIST fiber management system, providing a system of fiber management from

More information

Hard Disk Drive (HDD)

Hard Disk Drive (HDD) Installation Instructions Hard Disk Drive (HDD) Catalog Number 6189V-35HDDST80, 6189V-35HDDST160 Topic Page About This Publication 1 Important User Information 2 Electrostatic Discharge (ESD) Precautions

More information

InstaPATCH ZERO Solution Guide

InstaPATCH ZERO Solution Guide SYSTIMAX Solutions InstaPATCH ZERO Solution Guide Rapid Server Deployment and Change Management North, South and Central Americas 1 As data centers face ever-increasing IT demands, growth demands and evolving

More information

Small form factor bay converter and hard drive installation

Small form factor bay converter and hard drive installation Small form factor bay converter and hard drive installation HP xw6600 and HP xw8600 Workstations This document describes how to convert HP xw6600 and HP xw8600 Workstation 3.5-inch hard drive bays to hold

More information

Installation information. METTLER TOLEDO MultiRange Floor scales / Pit scales

Installation information. METTLER TOLEDO MultiRange Floor scales / Pit scales Installation information METTLER TOLEDO MultiRange Floor scales / Pit scales KC300/KCS300 KC600/KCS600 KD600/KD1500 KE1500/KE3000 KES1500/KES3000 KG3000/KG6000 KN1500 Floor scales / Pit scales Contents

More information

Installing Your 960 or 980 Server into a Rackmount Cabinet

Installing Your 960 or 980 Server into a Rackmount Cabinet Installing Your 960 or 980 Server into a Rackmount Cabinet 1 2 Contents Installing Your Gateway Server into a Rackmount Cabinet...1 Identifyingpartsintheaccessorykit...2 Rackmounthandlekit... 2 Rackmountrailkit...

More information

AU-110 racking guide NBXPN: 023

AU-110 racking guide NBXPN: 023 AU-110 racking guide NBXPN: 023 1. Overview NIMBOXX AU-110 Rack Installation This guide provides setup instructions for installing your NIMBOXX AU-110 in a rack. Following these steps in the order given

More information

Fiber Optic Cable Assemblies. Pigtails, Jumpers (simplex and duplex), Fanouts, Pre-connectorized Multi-Fiber Cable

Fiber Optic Cable Assemblies. Pigtails, Jumpers (simplex and duplex), Fanouts, Pre-connectorized Multi-Fiber Cable Fiber Optic Cable Assemblies Pigtails, Jumpers (simplex and duplex), Fanouts, Pre-connectorized Multi-Fiber Cable 1 Cable assemblies used in patch panels (Fiber Distribution Units) are an essential interface

More information

Intel RAID Maintenance Free Backup Unit 4 Quick Installation User's Guide

Intel RAID Maintenance Free Backup Unit 4 Quick Installation User's Guide Intel RAID Maintenance Free Backup Unit 4 Quick Installation User's Guide Thank you for buying an Intel RAID Maintenance Free Backup Unit 4. The Intel RAID Maintenance Free Backup Unit 4 supports the Intel

More information

Smart-UPS RT External Battery Pack Stack/Rack-Mount 6U

Smart-UPS RT External Battery Pack Stack/Rack-Mount 6U Smart-UPS RT External Battery Pack Stack/Rack-Mount 6U SURT192RMXLBP2 SURT192RMXLBP2J English 990-2485B 02/2009 Introduction About this UPS The American Power Conversion (APC ) SURT192RMXLBP2 external

More information

Next Generation Frame System

Next Generation Frame System Introduction Frames ADC KRONE S Next Generation Frame product line has fibre frames designed to fit a variety of termination, splice, and storage applications. Each frame option is designed with an emphasis

More information

Managing High-Density Fiber in the Data Center: Three Real-World Case Studies

Managing High-Density Fiber in the Data Center: Three Real-World Case Studies Managing High-Density Fiber in the Data Center: Three Real-World Case Studies CHALLENGE In today s data center, fiber optic links have become more vital than ever for transmitting data to and from a large

More information

HG600/HG800. Hydro-Power Unit. Installation and Operation Guide

HG600/HG800. Hydro-Power Unit. Installation and Operation Guide HG600/HG800 Hydro-Power Unit Installation and Operation Guide Copyright 04 HydroSpin, All rights reserved. The data contained in this document is proprietary to HydroSpin. It is disclosed to the receiving

More information

Co-location Interconnect Power Panel (CIPP) Installation Guide

Co-location Interconnect Power Panel (CIPP) Installation Guide Co-location Interconnect Power Panel (CIPP) Installation Guide Document INS-97xxxxxxx This guide covers the following part numbers- Trimm 97xxxxxxx Series Table of Contents Section 1 - General Information...

More information

HP ProLiant DL380 G6 Carrier-Grade Server Read Before Install

HP ProLiant DL380 G6 Carrier-Grade Server Read Before Install HP ProLiant DL380 G6 Carrier-Grade Server Read Before Install Carrier-Grade Instructions HP Part Number: AM275-9001A Published: July 2012 Edition: 3 Copyright 2009, 2012 Hewlett-Packard Development Company,

More information

RI-215A Operator s Manual. Part Number: 71-0045RK Revision 0 Released: 10/3/05

RI-215A Operator s Manual. Part Number: 71-0045RK Revision 0 Released: 10/3/05 RI-215A Operator s Manual Part Number: 71-0045RK Revision 0 Released: 10/3/05 Warranty RKI Instruments, Inc., warrants gas alarm equipment sold by us to be free from defects in materials and workmanship,

More information

COYOTE PUP CLOSURE FOR UNDERGROUND, AERIAL, AND BURIED SPLICES 6.0" x 17" (152.4 mm x 431.8 mm)

COYOTE PUP CLOSURE FOR UNDERGROUND, AERIAL, AND BURIED SPLICES 6.0 x 17 (152.4 mm x 431.8 mm) FEBRUARY 2005 COYOTE PUP CLOSURE FOR UNDERGROUND, AERIAL, AND BURIED SPLICES 6.0" x 17" (152.4 mm x 431.8 mm) Be sure to read and completely understand this procedure before applying product. Be sure to

More information

MCR1900 Media Converter 19-Slot Chassis

MCR1900 Media Converter 19-Slot Chassis MCR1900 Media Converter 19-Slot Chassis Installation Guide Part #5500304-11 Copyright Statement This document must not be reproduced in any way whatsoever, either printed or electronically, without the

More information

FL ADJUSTABLE RIDER BACKREST MOUNTING HARDWARE KIT

FL ADJUSTABLE RIDER BACKREST MOUNTING HARDWARE KIT -J070 REV. 0-0-0 FL ADJUSTABLE RIDER BACKREST MOUNTING HARDWARE KIT GENERAL Kit Number 9-09A Models For model fitment information, see the P&A Retail Catalog or the Parts and Accessories section of www.harley-davidson.com

More information

About the HotWire 7900 10-Slot Standalone Shelf

About the HotWire 7900 10-Slot Standalone Shelf TM HotWire Model 7900 10-Slot Standalone Shelf Installation Instructions Document Number 7900-A2-GN10-10 About the HotWire 7900 10-Slot Standalone Shelf The HotWire 7900 10-Slot Standalone Shelf is designed

More information

Installation Instructions

Installation Instructions Installation Instructions For Use with PXPV230, PXPV265, PXPD230, and PXPD265 models Attention! - Please read these instructions completely before attempting installation. Always unplug the power supply

More information

Cooktop Low-Profile Ventilation Hoods

Cooktop Low-Profile Ventilation Hoods INSTALLATION GUIDE Cooktop Low-Profile Ventilation Hoods Contents Wolf Cooktop Low-Profile Ventilation Hoods........ 3 Cooktop Low-Profile Hood Specifications.......... 4 Cooktop Low-Profile Hood Installation............

More information

BroadBand PowerShield. User Manual

BroadBand PowerShield. User Manual BroadBand PowerShield User Manual 990-0375G 12/2006 Chapter 1 General Information The PowerShield provides a power source for broadband telephony and other DC applications. Safety This Safety Guide contains

More information

INSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate Locks

INSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate Locks Securitron Magnalock Corp. www.securitron.com ASSA ABLOY, the global leader Tel 800.624.5625 techsupport@securitron.com in door opening solutions INSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate

More information

TABLE OF CONTENTS CABINET SAFETY

TABLE OF CONTENTS CABINET SAFETY CABINET SAFETY...2 ASSEMBLY INSTRUCTIONS...3 Tools and Parts...3 Cabinet Use Requirements...3 Unpack the Cabinet...3 TABLE OF CONTENTS CABINET SAFETY Install the Bumper...3 Install the Casters...4 Install

More information

Compaq Rack Options and Accessories. Monitors and Keyboards

Compaq Rack Options and Accessories. Monitors and Keyboards 1 Compaq Rack Options and Accessories Compaq offers a wide variety of rack options and accessories that help you to complete your 9000 and 10000 series racks. Monitors and Keyboards TFT5600RKM United States

More information

ADC Structured Cabling Solutions

ADC Structured Cabling Solutions ADC Structured Cabling Solutions The highest performing cross-connect system in the world HighBand Wall Mount Patching Solution Reliable, secure and cost effective ADC s HighBand cross connect solution

More information

SECURITY SYSTEM SMART SIREN KIT

SECURITY SYSTEM SMART SIREN KIT -J00876 REV. 009-0-09 SECURITY SYSTEM SMART SIREN KIT GENERAL Kit Number 688-0 Models For model fitment information, see the P&A Retail Catalog or the Parts and Accessories section of www.harley-davidson.com

More information

3M Quick Connect System (QCS) 2810 Models 2810A and 2810B

3M Quick Connect System (QCS) 2810 Models 2810A and 2810B 3M Quick Connect System (QCS) 2810 Models 2810A and 2810B Instructions October 2010 3 Contents 1.0 General...3 2.0 Recommended Installation Procedure for 3M Quick Connect Systems 2810A and 2810B...3 3.0

More information

2-3 SAS/SATA II HDD Canister USER S MANUAL XC-23D1-SA10-0-R. Document number: MAN-00076-A

2-3 SAS/SATA II HDD Canister USER S MANUAL XC-23D1-SA10-0-R. Document number: MAN-00076-A 2-3 SAS/SATA II HDD Canister XC-23D1-SA10-0-R USER S MANUAL Document number: MAN-00076-A ii Preface Important Information Warranty Our product is warranted against defects in materials and workmanship

More information

CamSplice Assembly Manual

CamSplice Assembly Manual Corning Cable Systems SRP-006-038 Issue 9, September 2000 Page 1 of 6 CamSplice Assembly Manual Table of Contents 1. General... 1 2. Precautions... 1 3. Tools and Materials... 2 4. Cable and Fiber Preparation...

More information

Foodservice Equipment Specialists P.O. Box 880 Saco, ME. / U.S.A. 04072 877-854-8006 * FAX (207) 283-8080

Foodservice Equipment Specialists P.O. Box 880 Saco, ME. / U.S.A. 04072 877-854-8006 * FAX (207) 283-8080 Foodservice Equipment Specialists P.O. Box 880 Saco, ME. / U.S.A. 04072 877-854-8006 * FAX (207) 283-8080 FOR SERVICE ASSISTANCE U.S. AND CANADA CALL: 1-877-854-8006 24 HOURS/DAY 7 DAYS/WEEK TABLE OF CONTENTS

More information

Bubble King. User Manual

Bubble King. User Manual Bubble King User Manual TABLE OF CONTENTS 1. Before You Begin... 3 What Is Included... 3 Unpacking Instructions... 3 Claims... 3 Text Conventions... 3 Icons... 3 Document Information... 3 Product at a

More information

Installation. Basic Rack Power Distribution Unit for Blade Servers

Installation. Basic Rack Power Distribution Unit for Blade Servers Installation Basic Rack Power Distribution Unit for Blade Servers Contents Preliminary Information...................1 Features............................. 1 Receiving inspection................... 1

More information

UB1 AIR CONDITIONING UNIT INSTALLATION INSTRUCTIONS

UB1 AIR CONDITIONING UNIT INSTALLATION INSTRUCTIONS UB1 AIR CONDITIONING UNIT INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS: Carefully read these instructions before installing your new air-conditioner. AUSTRALIAN AUTOMOTIVE AIR AL00500054E 1 Table

More information

HP ProLiant DL165 G7 Server. Installation Instructions

HP ProLiant DL165 G7 Server. Installation Instructions HP ProLiant DL165 G7 Server Installation Instructions Identifying server components Front panel components Figure 1 Front Panel Components / 4 3.5 HDD Item 1 Thumbscrews for rack mounting 2 Drive status

More information

Multiple Solutions for Connecting Multiple Dwelling Units (MDUs) WHITE PAPER

Multiple Solutions for Connecting Multiple Dwelling Units (MDUs) WHITE PAPER Multiple Solutions for Connecting Multiple Dwelling Units (MDUs) WHITE PAPER Multiple Solutions for Connecting Multiple Dwelling Units (MDUs) Abstract Fiber-to-the-Premises (FTTP) networks increasingly

More information

INSTRUCTION BOOK FOR. Single Monitor Video Conference Cart

INSTRUCTION BOOK FOR. Single Monitor Video Conference Cart INSTRUCTION BOOK FOR Single Monitor Video Conference Cart Procedure 1. Remove contents from cartons and examine for damaged or missing parts. The keys for the cabinet doors are tied to the outside of the

More information

Service Guide. Gateway M275

Service Guide. Gateway M275 Service Guide Gateway M275 Contents Replacing Gateway M275 Components.................................... 1 Identifying the convertible tablet PC model...................................... 2 Identifying

More information

REMOTE AUXILIARY AIR CONDITIONING SYSTEM AND AIR DISTRIBUTION

REMOTE AUXILIARY AIR CONDITIONING SYSTEM AND AIR DISTRIBUTION ENGLISH REMOTE AUXILIARY AIR CONDITIONING SYSTEM AND AIR DISTRIBUTION INSTALLATION GUIDELINES For International Prostar ISO 9001:2000 L 2647 Rev. 20090130 WARNING: Only trained technicians should perform

More information

HotLok Pass Through Blanking Panel

HotLok Pass Through Blanking Panel HotLok Pass Through Blanking Panel Part Numbers 1U - 10112 2U - 10113 Table of Contents Tools Required for Installation Page 2 Dimensions and Rack Requirements Page 2 Installation Procedures Page 3 Removal

More information

Compaq Presario Desktop Products. Upgrading and Servicing Guide

Compaq Presario Desktop Products. Upgrading and Servicing Guide Compaq Presario Desktop Products Upgrading and Servicing Guide The information in this document is subject to change without notice. Hewlett-Packard Company makes no warranty of any kind with regard to

More information

Rack Installation. Unpacking the System. Choosing a Setup Location. General Server Precautions. Barracuda Appliances

Rack Installation. Unpacking the System. Choosing a Setup Location. General Server Precautions. Barracuda Appliances This set of instructions applies to racking and rail kit installation for 6XX and above. The Rack Mounting Instructions section below provides information on installing the SC825 chassis into a rack unit

More information

AZEK Rail Install Guide

AZEK Rail Install Guide TRIM MOULDING DECK PORCH RAIL PAVERS AZEK Rail Install Guide Installing AZEK Rail with CableRail by Feeney... 1 Installing CableRail by Feeney for AZEK Rail... 7 Installing AZEK Rail Stairs with CableRail

More information

Installer s Guide WARNING: 18-GJ11D1-2. Ultraviolet (UV-C) Lamp Kit for 2-5 Ton Air Handlers HAZARDOUS VOLTAGE - DISCONNECT POWER BEFORE SERVICING

Installer s Guide WARNING: 18-GJ11D1-2. Ultraviolet (UV-C) Lamp Kit for 2-5 Ton Air Handlers HAZARDOUS VOLTAGE - DISCONNECT POWER BEFORE SERVICING Installer s Guide 18-GJ11D1-2 : Models: BAYUVCLK001-40 Watt, 2 Lamp NOTE: A BAYCC24VK01 can be installed for Series 8 Air Handlers to extend the life of the lamp. This accessory kit will disable the lamp

More information

Access Server Rack Cabinet Compatibility Guide

Access Server Rack Cabinet Compatibility Guide Access Server Rack Cabinet Compatibility Guide A Guide to the Selection and Evaluation of Access Server Rack Cabinets for Compatibility and Use with Third Party Server Chassis Kalkenstraat 91-93 B-8800

More information

2178-S Fiber Optic Splice Case

2178-S Fiber Optic Splice Case 2178-S Fiber Optic Splice Case Instructions March 1998 34-7041-6288-1-B 1 2 Table of Contents 3M 2178-S Splice Case Description... 4 1.0 General...4 2.0 Specifications...4 3.0 Kit Contents...5 3M 2178-S

More information

FDC Hardware Product Family

FDC Hardware Product Family FDC Hardware Product Family Introduction Corning Cable Systems designed the original FDC product family to organize and manage high fiber count cross-connect and interconnect installations, primarily in

More information

User Manual. RK-2d / RK-2t. dedicated KVM switch and rackmount screen technology. Designed and manufactured by Austin Hughes

User Manual. RK-2d / RK-2t. dedicated KVM switch and rackmount screen technology. Designed and manufactured by Austin Hughes dedicated KVM switch and rackmount screen technology User Manual RK-2d / RK-2t 1U Short Depth Keyboard Drawer Designed and manufactured by Austin Hughes 751 Legal Information First English printing, October

More information

GPS AutoSteer System Installation Manual

GPS AutoSteer System Installation Manual GPS AutoSteer System Installation Manual Supported Vehicles John Deere Sprayers 4720 4630 4730 4830 AutoTrac Ready PN: 602-0227-01-A LEGAL DISCLAIMER Note: Read and follow ALL instructions in this manual

More information

StorTrends 3400 Hardware Guide for Onsite Support

StorTrends 3400 Hardware Guide for Onsite Support StorTrends 3400 Hardware Guide for Onsite Support MAN-3400-SS 11/21/2012 Copyright 1985-2012 American Megatrends, Inc. All rights reserved. American Megatrends, Inc. 5555 Oakbrook Parkway, Building 200

More information

Installation Instructions

Installation Instructions READ BEFORE INSTALLING UNIT For Through-the-Wall Air Conditioners To avoid risk of personal injury, property damage, or product damage due to the weight of this device and sharp edges that may be exposed:

More information

Operating Instructions

Operating Instructions Operating Instructions Series L 4000 Spring Driven Cord Reels 63 3 3 3 7A 63 0 63 3 3-RP 3 7B 63 X 6 3 3A 63 8 3 X 6 3 3A-RP 63 8 L 4000 63 3 3 3B 63 9 L 400 63 3-RP A 63 5 3 9 L 4500 63 3 A 63 5 3 9G

More information

Navico-Northstar 2kW JRC Radar Package, Scanner Cable Removal and Replacement

Navico-Northstar 2kW JRC Radar Package, Scanner Cable Removal and Replacement Navico-Northstar 2kW JRC Radar Package, Scanner Cable Removal and Replacement This work instruction describes the methods and means for which to remove and reinstall optional scanner cable configurations

More information

Patch Cords for Data Center Applications

Patch Cords for Data Center Applications Applications General use of patch cords includes the interconnection of the optical fiber cable plant with opto-electronic equipment, and/or the cross-connection between cable plant segments. Pigtails

More information

USER MANUAL Stand Alone Power Supply PSQ 2909 / PSQ 3909 / PSQ 4909 PSQ 2920 / PSQ 3920 / PSQ 4920

USER MANUAL Stand Alone Power Supply PSQ 2909 / PSQ 3909 / PSQ 4909 PSQ 2920 / PSQ 3920 / PSQ 4920 USER MANUAL Stand Alone Power Supply PSQ 2909 / PSQ 3909 / PSQ 4909 PSQ 2920 / PSQ 3920 / PSQ 4920 [This page intentionally left blank] Warning for Your Protection 1. Read these instructions. 2. Keep these

More information

ADC-APC Integrated Cisco Data Center Solutions

ADC-APC Integrated Cisco Data Center Solutions Advanced Infrastructure Solution for Cisco Data Center 3.0 Ordering Guide ADC-APC Integrated Cisco Data Center Solutions The evolution of data centers is happening before our eyes. This is due to the

More information

INSTALLATION INSTRUCTIONS for Bifold Doors (JII103)

INSTALLATION INSTRUCTIONS for Bifold Doors (JII103) Thank you for selecting JELD-WEN products. Attached are JELD-WEN s recommended installation instructions for premium composite, hollow and solid core molded Bifold Doors. Bifolds are designed for fast

More information

Triple Expansion Chassis

Triple Expansion Chassis Triple Expansion Chassis AP9604 Installation Manual Contents Introduction............................. 1 Installation.............................. 2 Power Considerations...................... 5 Operations..............................

More information

HIROSE ELECTRIC U.S.A. Fiber Optic VAR July, 2015

HIROSE ELECTRIC U.S.A. Fiber Optic VAR July, 2015 HIROSE ELECTRIC U.S.A. Fiber Optic VAR July, 2015 Fiber Optic VAR Program Hirose Launches Fiber Optic Cabling VAR Program to provide a complete fiber optic cable assembly and wire harness solutions to

More information

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS PLEASE READ COMPLETE INSTRUCTIONS BEFORE YOU BEGIN LEAVE INSTALLATION INSTRUCTIONS AND USER'S GUIDE WITH OWNER ALL ELECTRIC WIRING AND PLUMBING MUST BE DONE

More information

Select Radiators Installation Guide

Select Radiators Installation Guide Select Radiators Installation Guide Table of Contents Informational Symbols...3 Before You Begin...4 Select Rough-In... 5 Connection Installation...6 Optional Piping Arrangements...7 Conventional Wall

More information

ADDING AN ELECTRIC AUXILIARY FAN TO RADIATOR STACK ON 03 ALPINE COACH

ADDING AN ELECTRIC AUXILIARY FAN TO RADIATOR STACK ON 03 ALPINE COACH ADDING AN ELECTRIC AUXILIARY FAN TO RADIATOR STACK ON 03 ALPINE COACH The original design of the 03 Alpine Coaches (and perhaps other years as well) did not include any kind of engine fan engage mechanism

More information

A QUICK AND EASY GUIDE TO SETTING UP THE DELL POWEREDGE C8000

A QUICK AND EASY GUIDE TO SETTING UP THE DELL POWEREDGE C8000 A QUICK AND EASY GUIDE TO SETTING UP THE DELL POWEREDGE C8000 A Principled Technologies setup guide commissioned by Dell Inc. TABLE OF CONTENTS Table of contents... 2 Introduction... 3 Dell 42U rack...3

More information

Packaged Terminal Air Conditioner Wall Sleeve Installation

Packaged Terminal Air Conditioner Wall Sleeve Installation Installation & Maintenance Data IM 1196 Group: PTAC Part Number: 910141799 Date: October 2013 Packaged Terminal Air Conditioner Installation x 42" PGAN with Top-Mounted Hydronic Heat Note: Installation

More information

MIRAGE. Set-Up Instructions. www.skyline-exhibits.com

MIRAGE. Set-Up Instructions. www.skyline-exhibits.com MIRAGE Set-Up Instructions www.skyline-exhibits.com Table of Contents Mirage is available in many sizes from 32 tall tabletops to 92 tall backwalls. The following set-up and repacking instructions depict

More information

OASIS-PLUS 120V READ ALL INSTRUCTIONS BEFORE OPERATING READ ALL INSTRUCTIONS BEFORE OPERATING OZONE IS A POWERFUL OXIDIZER AND MUST BE USED WITH CARE

OASIS-PLUS 120V READ ALL INSTRUCTIONS BEFORE OPERATING READ ALL INSTRUCTIONS BEFORE OPERATING OZONE IS A POWERFUL OXIDIZER AND MUST BE USED WITH CARE OASIS-PLUS 120V INFORMATION & OPERATING INSTRUCTIONS READ ALL INSTRUCTIONS BEFORE OPERATING READ ALL INSTRUCTIONS BEFORE OPERATING OZONE IS A POWERFUL OXIDIZER AND MUST BE USED WITH CARE 56041852 WARNING:

More information

Mercury Helios 2 ASSEMBLY MANUAL & USER GUIDE

Mercury Helios 2 ASSEMBLY MANUAL & USER GUIDE Mercury Helios 2 ASSEMBLY MANUAL & USER GUIDE TABLE OF CONTENTS INTRODUCTION...1 1.1 MINIMUM SYSTEM REQUIREMENTS 1.1.1 Apple Mac Requirements 1.1.2 PC Requirements 1.1.3 Supported PCIe Cards 1.2 PACKAGE

More information