1 March nd Edition More than insulation. Building Regulations L1A your guide to practical, affordable solutions. A practical insulation guide for builders and designers to meeting the new Part L 1A 2010 Building Regulations.

2 GLOBAL WARMING POTENTIAL Guide to Part L 1A Xtratherm Innovation - delivering better performance Xtratherm manufacture rigid thermal insulation for new build and refurbishment construction projects that deliver eco-friendly sustainable solutions. Xtratherm s experience and expertise is in providing cost-effective, certified solutions to the construction industry for over twenty years. The comprehensive range of technology foams offer the construction industry choice of specification and ultimately cost effective solutions to achieving Building Regulations and Zero Carbon fabric standards. The guide gives straightforward, affordable insulation solutions to meet the new standards for new dwellings, but as one of the main goals of the update is to work towards Zero Carbon standards, our guidance offers U-value solutions to achieve these advanced performance targets. With these improved fabric standards, it may allow for some more expensive technologies to be omitted and still achieve compliance with Part L Thin-R GREEN GUIDE A-RATED Rigid insulation technologies - flexible solutions 2 An inexhaustible combination of energy efficient measures are available to the specification builder/designer to meet the new Part L Regulations. However, re-arranging these combinations on a site of different house types with different energy requirements, will lead to confusion and costly errors being made. Showing compliance with an over-ambitious design might result in failure when finished measurements taken are less robust than planned for, leading to expensive remedial costs. A builder/designer should aim to achieve an effective building fabric first - lowering the energy target required - then look at how that energy is supplied

3 A major factor in the energy performance of a building is not simply the amount of insulation you install, but how it interconnects with its other components and the other insulated elements within the design. This is why detailing and jointing of the insulation layer has become a critical factor. It has been estimated that up to 30% of the heatloss in a well insulated house is through these Non Repeating Thermal Bridges. Xtratherm high performance rigid insulation offers practical, affordable solutions to meet the highest U-value performance with advanced engineered jointing to deliver the advanced detailing standards required for low energy design. Engineered jointing - the difference is in the detail. Why settle for less? 3

4 Guide to Part L 1A This guide is specific to the requirements of Part L1a 2010, that came into force on 1st October 2010, plans submitted for Building Control approval after this date need to comply with the new requirements. The starting principal for reducing emissions is to provide a well insulated building fabric as reflected in the latest update to the Building Regulations and the Code for Sustainable Homes. The fabric first approach has been stressed by the Zero Carbon Hub who have defined the Fabric Energy Efficiency Standard for the imminent Zero Carbon Standards. A best performing building fabric, through the attainment of good U-values, thermal bridging reduction with accurate detailing and improved airtightness, reduces the energy requirements, cuts CO 2 emissions and reduces energy bills. The following insulation solutions for Part L compliance have been expanded to include U-values indicative of Zero Carbon Homes. With the Zero Carbon Fabric Standard now in place under the Code and the content of the 2013 and 2016 regulations changes already well formulated the target U-values are readily attainable and might well allow for a reduction in more expensive technologies to achieve Part L compliance when used. Xtratherm offer practical, affordable solutions to meet the highest standards now. For comprehensive guidance on all aspects of the requirements to Part L1A see our Briefing Note to Part L1A 2010, and our guidance on extensions and refurbishment under Part L1B both documents downloadable from the Xtratherm web site. N.B. New requirements for party walls see note page 14. House Type 1 House Type 2 House Type 3 Model is 211 m 2 with five bedrooms and three bathrooms over three storeys. Model is 118 m2 with four bedrooms and two bathrooms over two storeys. Model is two storeys with an internal area of 76 m 2, comprising three bedrooms and two bathrooms. 4

5 More than insulation. The 2010 revision aims to: 1. Improve the energy efficiency of new buildings by approximately 25% (compared with those that met the previous 2006 regulations). 2. Improve the correlation between the predicted (TER) and actual (DER) performance of new buildings. 3. Continue along the path towards Zero Carbon buildings within the next decade. 4. To promote improvement of the existing building stock. Regulations now demands a whole building Approach to energy measurement based on carbon dioxide emissions, setting an overall Energy Performance target for new houses. This approach allows greater flexibility in the design but with that flexibility, the complexity of available solutions leaves the design vulnerable to failure. Although the tables contained at the back of this guide give indicative elemental U-values the Elemental approach to compliance is no longer available, a greater understanding of the principals of insulation in energy conservation is required in the context of the whole building approach. A best performing building fabric, through the attainment of good U-values, thermal bridging reduction with accurate detailing and improved airtightness, reduces the energy requirements cuts CO 2 emissions and reduces energy bills. The starting principal for reducing emissions is to provide a well insulated building fabric as reflected in the latest update to the Code for Sustainable Homes. The fabric first approach has been stressed by the Zero Carbon Hub that has defined the Fabric Energy Efficiency Standard for the imminent Zero Carbon Standards. Mixed development sites in England and Wales typically involve a number of house types, each with individual characteristics. We have taken this into consideration when formulating our specifications for the house types illustrated. Standardising thickness requirements for the insulation on a site is important. In the examples shown, we have achieved compliance using indicative values for all elements, allowing consistency in material specification for all house types thus reducing wastage and potential errors. The guidance is spilt into building elements, or Thermal Elements ie walls, roofs and floors that separate the internal, conditioned spaces from the exterior, or from unheated spaces. The tables give indicative U-values required for each element and show the thicknesses of insulation required to achieve that target, dependent compliance route is chosen. The full specification for the three house types shown is given on the fold out section at the back of this brochure. Guide to Table Colour Codes Renewable added solution - Fabric U-values required when fabric performance is off-set with Low & Zero Carbon Technologies (See page 16) Part L fabric only solution - Fabric U-values required when fabric is prioritized and LZCs avoided. Fabric Energy Efficiency Standard - Minimum standard indicated under the revised Code for Sustainable Homes for Zero Carbon. Beyond FEEs Standard - U-values indicated by the Zero Carbon Hub as meeting their Zero Carbon Solutions. 5

6 Guide to Part L 1A Building fabric insulation Cavity Walls Partial Fill Where exposure to wind driven rain excludes the use of full fill system, Xtratherm XT/CW(T&G) is the best solution in partially filled external masonry walls. Xtratherm boards achieve high standards of insulation whilst maintaining a residual cavity without a substantial increase in the width of the cavity and of the overall wall thickness. Partial Fill Cavity Wall (100mm & 125mm cavity max) Achievable Standards Renewable added solution 50mm Plus Liner* With an additional layer of Xtratherm Thermal Liner XT/TL added to the inner wall improvements in the U-value towards Zero Carbon targets are achieved. There is also a substantial improvement in thermal bridging PSI values achieved. Part L fabric only standard Fabric Energy Efficient standard Beyond FEEs (Zero Carbon) *Overall thickness of thermal liner inc plasterboard. Block W/mK. 75mm 50mm 50mm 50mm 37.5mm 50mm 72.5mm U-values - Partial Fill Insulation Only U-values - Partial Fill with liner Xtratherm CW Block Lambda Basic U-value With Liner* XT (mm) Block Lambda 0.11 Block Lambda mm Block Lambda mm Block Lambda mm Block Lambda *72.5mm overall thickness of thermal liner on dabs 0.022W/mK Thermal Conductivity (Certified) Low emissivity foil with a cavity resistance value of Outstanding thermal performance Robust tongue & groove jointing Clear cavity maintained Technical Approval Certificate No: 07/4407 6

7 More than insulation. Building fabric insulation Cavity Walls Full Fill The Building Regulations are committed to delivering Zero Carbon homes by The Government has now given the U-value targets to achieve Zero Carbon. CavityTherm will achieve the target wall U-value within traditional cavity widths. The CavityTherm wall insulation system works within a traditional 100mm cavity using traditional foundations, building skills and materials to achieve W/m 2 K. Maintaining the standard overall wall width means no loss of living space internally nor an enlarged building footprint. Full Fill Cavity Wall Achievable Standards Fabric Energy Efficient standard Beyond FEEs (Zero Carbon) 100mm 125mm The board includes specifically designed rebated edge detailing on all four edges to allow the system to tightly interlock when installed. *Includes aerated block W/mK with dot & dab plasterboard finish. Robust engineered jointing Installing Xtratherm CavityTherm in a 125mm cavity gives U-values that are indicative of targets set for Zero Carbon Standards - but within traditional construction allowing the architect to design low carbon homes and maintain a reasonable cavity width. Technical Approval Certificate No: 10/4786 Xtratherm CavityTherm has gas tight facings - with one additional HIP skin bonded to provide a drainage plane, directing moisture onto the outer leaf. A specially designed profile maintains a residual channel, protecting the structure. 75

8 Guide to Part L 1A Building fabric insulation Timber Frame Walls Xtratherm s Timber Frame Insulation Systems brings Timber Framed wall insulation performance to Zero Carbon levels, surpassing regulation values and meeting those required to meet the Fabric Energy Efficiency Standard and beyond. Timber Frame Wall Achievable Standards Renewable added solution Part L fabric only standard Fabric Energy Efficient standard Beyond FEEs (Zero Carbon) 140mm 140mm 140mm 140mm Includes insulated service void behind plasterboard. *0.19 U value achieved. Plus Liner 25mm* 25mm* 35mm 55mm Using a fibrous glass or stonewool type of material between studs is the most common method of insulating Timber Framed constructions. Although not as efficient in insulation values, the flexibility of the materials allows the insulation to be squeezed between studs with irregular spacings. Placing a lining of Xtratherm XT/SB Sheathing Boards into the traditional cavity of the construction, and effectively insulating the thermal bridging caused by the timber studding dramatically improves the insulation value of the walls. An alternative to applying a Sheathing Insulation into the cavity to improve the thermal bridging factor of the timber, is to place a lining of Xtratherm XT/TF over the studding to the inside face of the construction, thus improving the insulation value of the wall. An insulated service duct can be created by placing counter-battens between the Xtratherm and plasterboard finish allowing services to be placed without compromising the integrity of the vapour control layer and enhancing the air tightness. Technical Approval Certificate No: 08/4613 8

9 More than insulation. Building fabric insulation Thermal Lining Whether you are upgrading an existing property or building new, the addition of an insulated thermal lining to the inside of a wall, roof slope or ceiling will dramatically improve the energy efficiency standards in your home. Mechanically Fixed In many instances, older walls are not suitable for dot and dab application because they present an uneven surface. In such situations, the application of thermal liners using a mechanically fixed system onto timber framing/battens or a metal furring system might be appropriate to provide a level surface. Xtratherm Thermal Liners can also be mechanically fixed directly onto an even wall. Direct Bonding - Dot & Dab Xtratherm supply a range of Thermal Liners with tri-laminate paper facings specifically to accept adhesive type fixing systems such as dot & dab. Adhesive bonding of the Thermal Liners can be made to most masonry surfaces if the walls are plumb and in good condition. Existing plastered walls that are in good condition will also accept the adhesive dabs, any painted surface should be sanded back and treated with a PVA adhesive before applying adhesive dabs. Ribbons of adhesive should be placed around all wall edges and all openings and services on the wall to provide a fire stop and avoid air Technical Approval Certificate No: 04/4130 Thermal lining for new and refurbishment a practical affordable solution Outstanding thermal performance 9

10 Guide to Part L 1A Building fabric insulation Sarking Warm Roof Using Xtratherm insulation as a Sarking board to create a Warm Roof construction is a particularly effective way of insulating complex roofs. Roof Warm 600cs (XT/PR between & XT/SK over) Achievable Standards Sarking Renewable added solution 60mm 60mm Part L fabric only standard 70mm 75mm Fabric Energy Efficient standard mm 75mm Beyond FEEs (Zero Carbon) mm 75mm 600mm cs with approved breather membrane. High Thermal Performance Super-efficient U-value in roofs Effective Thermal bridging detailing Fully engineered jointing system Avoids thermal stress in roofs Insulating above the roof timbers ensures that the structure is kept at, or near the internal environmental conditions, reducing thermal stress and condensation risk. It also allows for the valuable area below the rafters to be used as additional living space, or makes access for the placement and maintenance of plant and technologies associated with low energy housing such as PV s, Solar Thermal and MVHR equipment. The Xtratherm Sarking Board XT/SK is a robust T&G engineered jointed board that achieves excellent U-values at minimal thicknesses. An additional layer of Xtratherm between the counter battens minimizes fixing length. Technical Approval Certificate No: 07/

11 More than insulation. Building fabric insulation Pitched Roof - Hybrid Placing Xtratherm XT/PR between and below the rafter offers an effective solutions when insulating dormer style roofs. The high performance to thickness ratio of Xtratherm gives the maximum insulation values with minimal intrusion into the living area below. Roof Hybrid 600cs (XT/PR between & XT/SK over) Achievable Standards Plus Liner Renewable added solution 100mm 42.5mm Part L fabric only standard 100mm 52.5mm Fabric Energy Efficient standard mm 72.5mm Beyond FEEs (Zero Carbon) mm 72.5mm 600mm cs, includes 25mm unvented void beneath breather membrane. The Hybrid Roof utilizes an approved Vapour Permeable (Breathable) underlay above the rafter allowing the traditional 50mm ventilation space to be dispensed with. A 25mm unvented void should be maintained; Agrément certification covering the membrane should be consulted. In a conventional ventilated roof a 50mm clear ventilation gap should be maintained between the insulation and the roofing felt. In certain instances when a vapour permeable membrane is used instead of standard roofing felt, the ventilation gap may be dispensed with. An effective vapour control layer should be installed when using breathable membranes. Placing a layer of Xtratherm Thermal Liner to the underside of the rafter provides a Robust Detail and substantially improves the U-values achieved, with minimum intrusion into valuable living space. Technical Approval Certificate No: 07/

12 Guide to Part L 1A Building fabric insulation Ceiling One of the easiest and most cost effective measures to increase the energy efficiency of a dwelling is to insulate the roof space at joist level. Roof Ceiling 600cs (fibre between & over, liner below) Achievable Standards Fibre Between Fibre Over Plus Liner Renewable added solution 100mm 150mm 29.5mm Part L fabric only standard mm 150mm 52.5mm Fabric Energy Efficient standard mm 150mm 72.5mm Beyond FEEs (Zero Carbon) mm 150mm 72.5mm includes 12.5mm plasterboard, 600mm cs With the substantial increase in thicknesses of fibre now asked for, consideration must be given to safe access to the roof space for the maintenance of any services that is placed within the roof space. Adding a layer of rigid insulation to the underside of the joists reduces the thickness of fibre and also provides better thermal bridging detailing at the wall junction. Xtratherm also produce an insulated roof access board that can be used to provide an insulated platform for safe access. Placing a layer of Xtratherm to the underside of the joists not only improves the overall U-value of the roof but crucially provides better thermal PSI value results for the gable junction. This particular junction is one of the major non-repeating thermal bridges that must be addressed to reduce the Y-value for the property as part of the endeavor to achieve low carbon design. Placing fibre glass over the joists hides the top of the joists and may lead to health and safety concerns when the roof space is being accessed. An Xtratherm solution to covering the thermal bridge through the joists is to place a layer of Xtratherm to the underside of the joist before the plasterboard is fixed. Additional fibre can be added above the joists when safe access is provided by the use of Xtratherm Loft Walk-R Outstanding thermal performance Simple installation 12

13 More than insulation. Building fabric insulation Floors Achieving a U-value of W/m 2 K or better should be set as a goal for all floors as the costs of material and installation required to achieve this goal over the current building regulation standards is relatively small. Solid Floor (75mm screed) Perimeter/Area (P/A) FEEs Standard Standard Achieved Beyond FEEs Standard Achieved Suspended Beam & Block Floor (75mm screed) Perimeter/Area (P/A) FEEs Standard Standard Achieved Heatloss from a floor is easily rectified through an increase in the insulation thickness. Xtratherm s thermal conductivity of 0.022W/mK minimizes the thickness required. Detailing at junctions is also critical as heat loss occurs through bad jointing and the floor perimeter. The detailing at the floor/wall junction is critical to avoid thermal bridging. Beyond FEEs Standard Achieved Placing an upstand of Xtratherm insulation at the floor edge will alleviate the problem and is obligatory under the Building Regulations. Xtratherm underfloor insulation is ideal for use with Under Floor Heating systems. It is recommended to provide maximum U-values when UFH is installed. Xtratherm Hyfloor is an engineered jointed, T&G all four edges high performance Under Floor Insulation consisting of a high performance rigid Polyisocyanurate (PIR) core with branded gas tight facings both sides, it has a thermal conductivity of 0.022W/mK. Technical Approval Certificate No: 07/4406 Construction friendly product Tongued & grooved 2400 x 1200mm High compressive strength High cross breaking strength Lambda Value W/mK Certified 13

14 Guide to Part L 1A Building fabric insulation Engineered jointing Thermal Bridging...the difference is in the detail A major factor in the performance of the building fabric is not simply the amount of insulation you install, but how it interconnects with its other components and the other insulated elements within the design. Take a wall construction for example: you may indeed succeed in achieving a very good U-value by increasing the cavity and adding more insulation, but in the well insulated building that is required for Code level 3 and beyond, most of the fabric heat loss will not be through the main body of the wall, floor or roof - but at the junctions where those elements meet. This is why detailing and jointing of the insulation layer has become a critical factor in energy efficient design. It has been estimated that up to 30% of the heatloss in a well insulated house is through these Non Repeating Thermal Bridges at wall/floor junctions, corners, reveals, ceiling junctions heads and sills. Thermal bridging through standard SS wire ties in 100mm cavity. Appropriate detailing to ensure the Continuity of insulation is now asked for by Part L, and this continuity can be satisfied by following details printed in the publication Accredited Construction Details, published by the DCLG. Using these details will allow the assessor to ascribe a good score to the detailing section within SAP and allow for a Y-value to be calculated. The target Y-value for the Fabric Energy Efficiency standards is approximately Y= Guidance can be found in the paper IP1/06 Assessing the effects of thermal bridges at junctions and around openings. Party Walls The revised Part L has introduced new requirements for party walls. This is to reflect research that shows that party walls with unsealed and/or unfilled cavities have significant convective heat loss into roof spaces. Penalties for not sealing or filling the cavity space between properties makes compliance extremely difficult. However as no target U-values are quoted, low performance, low cost fibrous insulation material will suffice as a cavity fill in this element of the build, along with effective edge sealing. Increased Thermal bridging through bigger ties in wider cavity. 14

15 More than insulation. Technical Notes GLAZING / DOOR PERFORMANCE The performance of glazing and doors can have a significant effect on the overall energy performance of a dwelling. Whilst the building regulations ask for an average U-value of 2.2 W/m 2 K to be achieved, a single solid timber door with a U-value of 3 W/m 2 K can mitigate any improvement of glazing below so an overall approach to the specification should be followed. As with other inputs into a SAP calculation, the glazing performance must be accredited by certification for the SAP Assessor to accept the claims; your glazing supplier should be able to provide such certification. The thermal performance of openings depends on a number of factors including the design, the materials used, including the glass, the cavity and framing material itself. Double glazing has now been standard specification for some time, but improvement on the standard performance can be made by the inclusion of certain technologies. Low emissivity coatings on the glass itself, either hard coat low-e or improved soft coat Low E will improve performance. Within the cavity space between the glass, the inclusion of argon gas filling will improve the U-value. And in the design of the frame material itself, thermal breaks within the frame construction can significantly improve overall window U-values. While the specification of better glazing U-values is crucial for low energy design - it is not the only factor. Good air permeability is also reliant on window and door frames being properly sealed. Poorly sealed opening casements and sashes can result in further heatloss. Your window supplier will be able to advise. (see for further information) VENTILATION & AIR PERMEABILITY Air leakage from buildings, the uncontrolled flow of air through gaps and cracks in the fabric of dwellings (sometimes referred to as infiltration, exfiltration or draughts) is a major cause of energy loss and increased CO 2 emissions. Improving airtightness in dwellings will reduce air leakage. Too much air leakage leads to unnecessary heat loss and discomfort from cold draughts. With more stringent building regulations requiring better energy efficiency, airtightness is an increasingly important issue, the new regulations ask for a minimum air permeability of 10m 3 /m 2 /yr at Q10. Our solutions ask for an air permeability of 6 to be achieved. Following the Enhanced Accredited Details should improve the permeability to around 4. The aim should be to build tight - ventilate right. Buildings cannot be too airtight; it is, however, essential to ensure appropriate ventilation. Ventilation, the controlled flow of air into and out of the dwelling through purpose-built ventilators is required to provide good air quality for the comfort and safety of the occupants. Ventilation methods commonly used include trickle vents, extract fans, and openable windows. Whatever method is installed, it should work in harmony with the energy efficiency principle of the house in mind, any mechanical systems will use energy to run. Mechanical ventilation may become necessary as the air permeability is improved better then 4 m 3 /m 2 /h at 50P. At this point combining the ventilation with heat recovery can become very effective - look for efficiencies of the systems and importantly the Specific Fan Power. THERMAL BRIDGING (see opposite) Insulation components should come together to form a continuous layer throughout the design. Enhanced detailing asks that all rigid insulation materials be engineered (T&G) jointed rather than square edge to achieve continuity. Xtratherm have recognised the importance of effective jointing of components and elements and have developed innovative system components to improve overall insulation performance. In walls, the Xtratherm insulation system includes preformed corner panels and reveal panels for openings that knit with the main cavity wall insulation perfectly. In roofing the Xtratherm Rafterloc pre-cut rafter panels expand to fill rafter spaces whilst in the floor our Hyfloor boards now come with full T&G jointing and perimeter strip. For full details see the installation animations on or contact Xtratherm Technical Support for full Thermal Bridging information. Technical Notes continued overleaf. 15

16 Technical Notes (cont d) RENEWABLES Low & Zero Carbon Technologies (LZCs) As previously mentioned, the first step in energy efficiency in new build is to provide a robust, energy efficient building fabric before incorporating any Low or Zero Carbon Technologies (LZCs). It does not make sense to install renewable generation into a design if much of the output is to be wasted through inefficient usage. The building fabric will last a lot longer than the services that are put into it. Most technologies such as boilers, glazing, and renewables will be replaced within one or two decades. It is therefore vital to get the fabric right at time of construction. It is always more costly to insulate properly at a later stage. Solar Gain The Free energy good design takes advantage of solar gain, but difficult to predict and control in the our climate. When designing to take advantage of solar gain, the heating and ventilation system used within the design should be very responsive to temperature fluctuations. Solar Water Heaters Can provide up to 50% of hot water requirements on a SE-SW roof, available as flat plate or vacuum tube systems, normally require the installation of higher volume storage cylinders. Photovoltaics (PV) Uses energy from the sun to create electricity to run appliances and lighting. PV requires only daylight to generate electricity. A typical array would cover 10-15m 2 of roof area. HEATING Energy to heat the space will be necessary in all houses including Passive/Low carbon houses at certain periods in the year. The task is to supply that energy requirement as efficiently as possible by choosing a cleaner fuel - natural gas is cleaner than oil or electricity, and burning it as efficiently as possible, boilers should perform above the 86% minimum efficiency but can be sourced over 90% efficient. Burning biomass - logs or pellets which are carbon neutral will also reduce carbon production. Heating Controls - Boiler based heating systems should incorporate: space heating control on the basis of room temperature (room thermostats and/or TRVs); water heating control on the basis of stored water temperature (cylinder thermostats); separate and independent time control of space heating and water heating; and boiler interlock (i.e. the boiler does not fire when there is no demand for space or water heating). Equivalent control should provided for other types of systems. Good practice guide CE51 from the BRE gives invaluable information on the specification of control systems. ENERGY EFFICIENT LIGHTING As we achieve better control of space heating through effective insulation of the building fabric and good control of our hot water needs - the energy demand for lighting becomes a bigger proportion of the energy demand and a major contributor to CO 2 production, not least because the energy is electric based which is a costly fuel and dirtier than all other fuels. Using energy efficient light fittings will reduce CO 2. Although we should aim to have 100% energy efficient lighting - fashions dictate that this is not always possible and should be reflected as such in the calculations. Pellet Stoves Energy from biomass is produced from organic matter of recent origin - not fossil fuels. The CO 2 released during burning is balanced by the CO 2 absorbed during the fuel s production - this is Carbon Neutral. Storage of pellets is a major consideration. Ground Source Heat Pump The ground keeps a constant temperature of about 11-12ºC. Ground source heat pumps (GSHP) can transfer this heat into a building to provide space heating. For every unit of electricity used to pump the heat, units of heat are produced. Particularly suitable for under floor heating because of lower operating temperatures. 16

17 More than insulation. Specification and U-value targets General Spec based on: Low energy lights 100% Thermal bridging 0.08 Gas boiler (Combi) 90% Heating controls Weather compensator Thermal mass Full T&T Yes Medium Detached House - TER DESCRIPTION PART L FABRIC MECHANICAL SOLUTIONS ONLY STANDARD SOLAR PANELS PV PANELS MVHR Walls 0.25 Floors 0.17 Roof (Ceiling) 0.10 House Type 1 Roof (Sloped) Semi E wall Semi E Floors Model is 211 m 2 with five bedrooms and three bathrooms over three storeys. Dormer cheek Windows Doors Air Permeability Renewables 5m 2 (Gross) 0.6 KWp MVHR SFP 0.85 eff 90% DER Semi-detached House - TER DESCRIPTION PART L FABRIC MECHANICAL SOLUTIONS ONLY STANDARD SOLAR PANELS PV PANELS MVHR Walls Floors 0.17 Roof House Type 2 Windows Doors Air Permeability Model is 118 m 2 with four bedrooms and two bathrooms over two storeys. Renewables 4m 2 (Gross) 0.5 KWp MVHR SFP 0.85 eff 90% DER Terrace House - TER DESCRIPTION PART L FABRIC MECHANICAL SOLUTIONS ONLY STANDARD SOLAR PANELS PV PANELS MVHR Walls 0.25 Floors Roof (Ceiling) 0.10 House Type 3 Roof (Sloped) Roof (Flat) Dormer cheek Model is two storeys with an internal area of 76 m 2, comprising three bedrooms and two bathrooms. Windows Doors Air Permeability Renewables 2m 2 (Gross) 0.4 KWp MVHR SFP 0.85 eff 90% DER

18 GLOBAL WARMING POTENTIAL Technical Support Xtratherm Technical Support team provide a single point of contact to offer assistance on a wide range of issues for both the designer and builder and can be contacted by phone, fax or . Full details of all Xtratherm products, along with full technical literature can be downloaded from the website at: Xtratherm UK Limited Park Road, Holmewood Chesterfield, Derbyshire S42 5UY Tel: Fax: ISO 9001 Quality Management Systems ISO Environmental Management ISO Occupational Healty & Safety GREEN GUIDE A-RATED Good workmanship and appropriate site procedures are necessary to achieve expected performance. The information contained in this publication is, to the best of our knowledge, true and accurate but any recommendations or suggestions which may be made are without guarantee since the conditions of use are beyond our control. Xtratherm reserve the right to change the content of this publication without prior notice.

XT/TF. High performance PIR timber frame insulation board. Insulation for timber framed walls. OCTOBER Affordable innovation.

XT/TF. High performance PIR timber frame insulation board. Insulation for timber framed walls.  OCTOBER Affordable innovation. OCTOBER 2010 Affordable innovation. High performance PIR timber frame insulation board Insulation for timber framed walls XT/TF COST EFFECTIVE THERMAL SOLUTIONS www.xtratherm.com Timber Frame Insulation

More information

Building fabric performance and the code for sustainable homes

Building fabric performance and the code for sustainable homes More than insulation. Building fabric performance and the code for sustainable homes Insulation for performance UK 2009 2nd Edition www.xtratherm.com More than insulation. Xtratherm Innovation - delivering

More information

Thermal Bridging & Y-Value Calculator. Easy Reference Guide.

Thermal Bridging & Y-Value Calculator. Easy Reference Guide. Thermal Bridging & Y-Value Calculator Easy Reference Guide Thermal Bridging & Y-Value Calculator Easy Reference Guide 1. What is Y-Calculator? 2. Y-Calculator User Guide 2.1 Get Started! 2.2 SAP Choice

More information

Full Fill Built-in Insulation for Traditionally Built Walls

Full Fill Built-in Insulation for Traditionally Built Walls The Affordable Solution The Practical Solution The Technical Solution The Desirable Solution Full Fill Built-in Insulation for Traditionally Built Walls Traditional wall construction to Zero Carbon targets

More information

Traditional build. CavityTherm CT/PIR. with extra-ordinary U-values. Affordable Innovation

Traditional build. CavityTherm CT/PIR. with extra-ordinary U-values. Affordable Innovation Affordable Innovation 2011 March Traditional build with extra-ordinary U-values CavityTherm CT/PIR BUILT-IN CAVITY FILL INSULATION The logical way to achieve U-values as low as 0.16 W/m 2 K from a standard

More information

CavityTherm BUILT-IN CAVITY FILL INSULATION

CavityTherm BUILT-IN CAVITY FILL INSULATION Affordable Innovation 2011 May Traditional build with extra-ordinary U-values CavityTherm BUILT-IN CAVITY FILL INSULATION Achieve 0.12W/m 2 K U-value in a traditional construction without a structural

More information

Building your own energy efficient house

Building your own energy efficient house GOOD PRACTICE GUIDE 194 Building your own energy efficient house Why save energy How to achieve integrated design Checklist for a low energy home Further information GOOD PRACTICE GUIDE 194 2001 2001 EDITION

More information

Energy Company Obligation (ECO): Technical Monitoring Questions

Energy Company Obligation (ECO): Technical Monitoring Questions Energy Company Obligation (ECO) Technical Monitoring Questions v1 30/05/2013 Energy Company Obligation (ECO): Technical Monitoring Questions Under ECO suppliers are required to instruct suitably qualified

More information

Innovation - High performance roof, wall and floor insulation board. delivering better performance

Innovation - High performance roof, wall and floor insulation board. delivering better performance 2010 VERSION 1 IRL High performance roof, wall and floor insulation board Innovation - delivering better performance PRODUCT SPECIFICATION INSTALLATION GUIDE I ve worked with Xtratherm for years, they

More information

Masonry: Cavity Wall Insulation: Partial Fill Isometric cut-away view

Masonry: Cavity Wall Insulation: Partial Fill Isometric cut-away view Legend Insulation zone Blue text Air tightness barrier (note: this can also act as a vapour control layer) Guidance on thermal continuity Red text Guidance on air tightness Values used in psi calculations

More information

Timber Frame Isometric cut-away view

Timber Frame Isometric cut-away view Legend Insulation zone Blue text Red text Air tightness barrier (note: this can also act as a vapour control layer) Guidance on thermal continuity Guidance on air tightness Values used in psi calculations

More information

(4) ( 4 TIMBER ) T FRAME I M B E R F R A M E J U L Y

(4) ( 4 TIMBER ) T FRAME I M B E R F R A M E J U L Y (4) ( 4 TIMBER ) T FRAME I M B E R F R A M E J U L Y 2 0 0 8 INTRODUCTION The details within this section are valid for a range of timber frame wall thicknesses from 89mm up to 210mm stud size. Details

More information

Part L 2010 where to start: An introduction for house builders and designers

Part L 2010 where to start: An introduction for house builders and designers Part L 2010 where to start: An introduction for house builders and designers Acknowledgements This guide was written and published for NHBC Foundation by Richards Partington Architects www.rparchitects.co.uk

More information

U-Values of Elements

U-Values of Elements Building Control Guidance Note 22 U-Values of Elements A guide to the specification of insulation materials in order to achieve compliance with Approved Document L1A& L1B 2006 of the Building Regulations

More information

GUIDANCE SHEET FOR CONSERVATORIES, SUNROOMS AND EXTENSIONS TO DWELLINGS.

GUIDANCE SHEET FOR CONSERVATORIES, SUNROOMS AND EXTENSIONS TO DWELLINGS. GUIDANCE SHEET FOR CONSERVATORIES, SUNROOMS AND EXTENSIONS TO DWELLINGS. This leaflet provides guidance on how to attain compliance with The Building (Amendment) Regulations (Northern Ireland) 2006, Part

More information

U-Value Calculations

U-Value Calculations Leaving Certificate Revision Notes U-Value Calculations www.constructionstudies.ie Construction Studies Notes vapour barrier insulation plasterboard Notes: Thermal insulation U value calculations timber

More information

Report Date: 04/03/2014. Assessor: John Doyle Address: BLOCK K APT 108 SANDYFORD VIEW DUBLIN 18 BER: 106178106 MPRN: 10301589669

Report Date: 04/03/2014. Assessor: John Doyle Address: BLOCK K APT 108 SANDYFORD VIEW DUBLIN 18 BER: 106178106 MPRN: 10301589669 Report Date: 04/03/2014 Assessor: John Doyle Address: BLOCK K APT 108 SANDYFORD VIEW DUBLIN 18 BER: 106178106 MPRN: 10301589669 About this Advisory Report Energy use in our homes is responsible for almost

More information

Masonry Cavity Wall and Plasterboard Laminate

Masonry Cavity Wall and Plasterboard Laminate Issue 1, September 2013 CI/SfB (2 -) Rn7 (M2) Masonry Cavity Wall and Plasterboard Laminate Introduction Celotex is the brand leading manufacturer of PIR insulation boards, with its range encompassing

More information

Appendix 4 - Standard technical monitoring questions

Appendix 4 - Standard technical monitoring questions Appendix 4 - Standard technical monitoring questions General questions Survey company Name of surveyor completing form Name of householder Address of householder Date of installation Date of inspection

More information

Introduction & Principles Issued in support of Junction Details, Parts 1 to 5

Introduction & Principles Issued in support of Junction Details, Parts 1 to 5 Accredited Construction Details (Scotland) 2010 For the limitation of thermal bridging and air infiltration in low and medium rise domestic buildings Introduction & Principles Issued in support of Junction

More information

Timber Frame. TFW-EW-01 Wall Junction. THERMAL PERFORMANCE OF JUNCTION AIR BARRIER CONTINUITY AIR BARRIER OPTIONS GENERAL NOTES VERSION 1.

Timber Frame. TFW-EW-01 Wall Junction. THERMAL PERFORMANCE OF JUNCTION AIR BARRIER CONTINUITY AIR BARRIER OPTIONS GENERAL NOTES VERSION 1. Ensure insulation is tucked into corners. AIR BARRIER S Accredited (Indicative) Detail Number: TFW-EW-0 TFW-EW-0 Wall Junction. Floor insulation must tightly abut the inner face of the timber frame soleplate.

More information

Energy efficiency and the Code for Sustainable Homes

Energy efficiency and the Code for Sustainable Homes CE291 Energy efficiency and the Code for Sustainable Homes Level 4 Also available: Energy efficiency guidance for level 3 Energy efficiency guidance for levels 5 and 6 Contents 1. Introduction 3 1.1 Energy

More information

Energy Performance Certificate

Energy Performance Certificate Energy Performance Certificate 11 Hirwain Street CARDIFF CF24 4JG Dwelling type: Date of assessment: Date of certificate: Reference number: Total floor area: Mid-terrace house 23 July 2009 24 July 2009

More information

Structural Timber Association Building Low Carbon Timber Frame Homes

Structural Timber Association Building Low Carbon Timber Frame Homes Structural Timber Association Building Low Carbon Timber Frame Homes STA what we do TRADE BODY for - Timber Frame SIPS- CLT- Glulam Engineered wood products (see www.structural timber.co.uk for more information)

More information

Rockwool Flexi Insulation Application Guide

Rockwool Flexi Insulation Application Guide Pitched roof Rafters InterMediate floors INTERNAL partitions external Framed walls separating floors Separating Walls Rockwool Flexi Insulation Application Guide Ground floor The perfect fit for any framed

More information

6 STAR ENERGY EFFICIENCY HOUSES

6 STAR ENERGY EFFICIENCY HOUSES YOUR GUIDE TO 6 STAR ENERGY EFFICIENCY HOUSES IN TASMANIA 2014 Department of Justice Building Standards and Occupational Licensing P: 1300 366 322 E: wstinfo@justice.tas.gov.au W: www. justice.tas.gov.au

More information

Topic 3 Understanding the Energy Requirements

Topic 3 Understanding the Energy Requirements Topic 3 Understanding the Energy Requirements Planning for Climate Change - Delivering Sustainable Buildings & Quality Design Learning Objectives By the end of this session, you should have a basic understanding

More information

TIMBER FRAME APPLICATION NOTES INTRODUCTION

TIMBER FRAME APPLICATION NOTES INTRODUCTION Tŷ-Mawr Ecological Building Materials TIMBER FRAME APPLICATION NOTES INTRODUCTION This application guidance is aimed at ensuring you make the best use of the Thermafleece range of insulation when used

More information

Contents. APA Construction Details. Full fill cavity walls 2-13. Partial fill cavity walls 14-25. Solid externally insulated walls 26-37

Contents. APA Construction Details. Full fill cavity walls 2-13. Partial fill cavity walls 14-25. Solid externally insulated walls 26-37 Contents Pages Full fill cavity walls 2-13 Partial fill cavity walls 14-25 Solid externally insulated walls 26-37 Appendix (BRE confirmation of Ψ and y-values) 38-40 Page 1 of 40 APA Construction Details

More information

Environmentally-Friendly Building Products from Renewable Resources. Product range overview. We care about INT. natural building products

Environmentally-Friendly Building Products from Renewable Resources. Product range overview. We care about INT. natural building products Environmentally-Friendly Building Products from Renewable Resources Product range overview We care about INT natural building products Wood and Hemp Nature s Eternal Gifts As a sustainable building material,

More information

Rochdale Building Control Guide. Garage Conversions

Rochdale Building Control Guide. Garage Conversions Rochdale Building Control Guide Garage Conversions Garage conversions are often seen as a simple way of obtaining additional living space, however care is needed when dealing with existing buildings. This

More information

Garage conversion guidance note

Garage conversion guidance note Garage conversion guidance note Bracknell Forest Building Control POLICY GUIDANCE THE BUILDING REGULATIONS 2010 Regulation 3, Schedule 1 This Guidance Note is for the benefit of local architects, builders

More information

main heating: pre1998 ducted warm air system main heating fuel: mains gas main heating SAP efficiency: 70.0% main heating controls: programmer

main heating: pre1998 ducted warm air system main heating fuel: mains gas main heating SAP efficiency: 70.0% main heating controls: programmer Archetype: 3250330 Archetype Description: 1965-1975, semi / end terraced dwelling, timber frame walls, oil / gas / electric warm air heating, E This archetype represents 823 dwellings, which accounts for

More information

The Visqueen VAPOUR control

The Visqueen VAPOUR control VAPOUR CONTROL LAYERS Visqueen VAPOUR BARRIERS Range suitable for all internal building conditions. Used within roof, wall and floor constructions. Reduces the likelihood of interstitial condensation.

More information

Energy Performance Certificate

Energy Performance Certificate Energy Performance Certificate 159, Moy Road CARDIFF CF4 4TH Dwelling type: Mid-terrace house Date of assessment: 1 July 009 Date of certificate: 4 July 009 Reference number: 801-663-680-8419-40 Total

More information

Section 3.1.2. Timber Frame Walls. Single layer between studs. Single layer between studs with service void. Between studs with insulated lining

Section 3.1.2. Timber Frame Walls. Single layer between studs. Single layer between studs with service void. Between studs with insulated lining Section Timber Frame Walls Single layer between studs Product: Earthwool FrameTherm Rolls and Slabs Tf01 Single layer between studs with service void Product: Earthwool FrameTherm Rolls and Slabs Tf02

More information

BUILDING CONTROL GUIDANCE SHEET USE OF BREATHABLE ROOFING FELTS.

BUILDING CONTROL GUIDANCE SHEET USE OF BREATHABLE ROOFING FELTS. Building Control Charnwood Borough Council Southfield Road Loughborough LE11 2TN BUILDING CONTROL GUIDANCE SHEET USE OF BREATHABLE ROOFING FELTS. Last updated 16/11/2010 Page 1 of 6 PURPOSE: This Guidance

More information

Energy Performance Certificate

Energy Performance Certificate Energy Performance Certificate 177, Heritage Park, St. Mellons Dwelling type: Mid-terrace house CARDIFF CF3 0DT Date of assessment: Date of certificate: Reference number: Type of assessment: 27 November

More information

Energy Performance Certificate

Energy Performance Certificate Energy Performance Certificate 47 Penydarren Drive CARDIFF CF14 2TT Dwelling type: Date of assessment: Date of certificate: Reference number: Type of assessment: Total floor area: Mid-terrace house 27

More information

your house, your home

your house, your home your house, your home ABOUT US Manufacturing timber frame homes since 1996 Based in Macroom, Co Cork Industry leaders in Timber Frame manufacturing Wide range of sustainable Timber Frame options The only

More information

Building Regulations for the Conservation of Fuel and Power

Building Regulations for the Conservation of Fuel and Power Insulation CI/SfB Rn7 M2 First Issue April 2014 Building Regulations for the Conservation of Fuel and Power ENGLAND EXISTING DWELLINGS 2013 EDITION Low Energy Low Carbon Buildings Contents Page Introduction

More information

Multi-layer Insulation Blanket for Roofs

Multi-layer Insulation Blanket for Roofs Multilayer Insulation Blanket for Roofs Thermal Insulation in a 40mm thin, flexible, multilayer membrane Meets requirements of L1A, L1B 2010 In accordance with BR443 NHBC Acceptance Pitched & Flat roof

More information

Energy Performance Certificate

Energy Performance Certificate Energy Performance Certificate 87, Cardiff Road Dwelling type: End-terrace house ABERDARE Date of assessment: 02 October 2009 CF44 6TR Date of certificate: 15 October 2009 Reference number: 0328-5914-6290-6021-1084

More information

Air & Sound Testing for Timber Frame Companies

Air & Sound Testing for Timber Frame Companies APT PLEASE CONTACT AIR PRESSURE TESTING NOW FOR A RAPID PROACTIVE RESPONSE FOR ALL YOUR AIR & SOUND TESTING Air & Sound Testing for Timber Frame Companies Air Pressure Testing are a members of the British

More information

Timber Frame Walls Rethinking Construction

Timber Frame Walls Rethinking Construction Insulation Fifth Issue November 2007 Timber Frame Walls Rethinking Construction INSULATION BEST PRACTICE FOR THE 21ST CENTURY Summary 9 mm OSB sheathing 3 mm skim coated 15 mm plasterboard Rock or glass

More information

Consultation Questions - Specific issues where comment is requested.

Consultation Questions - Specific issues where comment is requested. Reducing carbon dioxide emission and energy demand in new buildings - proposed amendment of the Building (Scotland) Regulations 2004 and accompanying standards and guidance within Section 6: Energy and

More information

BUILDING CONTROL GUIDANCE SHEET REPLACEMENT WINDOWS AND DOORS Last updated 16/11/2010

BUILDING CONTROL GUIDANCE SHEET REPLACEMENT WINDOWS AND DOORS Last updated 16/11/2010 Building Control Charnwood Borough Council Southfield Road Loughborough LE11 2TN BUILDING CONTROL GUIDANCE SHEET REPLACEMENT WINDOWS AND DOORS Last updated 16/11/2010 Page 1 of 6 PURPOSE: This Guidance

More information

SAP 2012 IN A NUTSHELL

SAP 2012 IN A NUTSHELL SAP 2012 IN A NUTSHELL The consultation version of the SAP 2012 methodology was published by the Department of Energy and Climate Change (DECC) on January 4th 2012. This article from Dyfrig Hughes of National

More information

(92 plus) (81-91) (69-80) (55-68) (39-54) (21-38) (1-20)

(92 plus) (81-91) (69-80) (55-68) (39-54) (21-38) (1-20) Energy Performance Certificate Georgia House Stud Bradley Road Burrough Green NEWMARKET CB8 9NH Dwelling type: Detached house Date of assessment: 17 August 2011 Date of certificate: 17 August 2011 Reference

More information

The A-rated Energy-Efficient Concrete Home

The A-rated Energy-Efficient Concrete Home Concrete Built is Better Built Concrete is present in almost every home in Ireland. Its strength, durability, fire resistance, sound insulation and water resistant qualities make it indispensable in foundations,

More information

V2/0815/CWI/TD02. KORE Fill Cavity Wall Insulation. Wall Insulation Design Guide

V2/0815/CWI/TD02. KORE Fill Cavity Wall Insulation. Wall Insulation Design Guide V2/0815/CWI/TD02 Cavity Wall Insulation Wall Insulation Design Guide Bonded Bead Key Features Meets and exceeds building regulations Suitable for passive house construction Installed by insulation experts

More information

(81-91) (69-80) (55-68) (39-54) (21-38) (1-20)

(81-91) (69-80) (55-68) (39-54) (21-38) (1-20) Energy Performance Certificate 120, Loudoun Road Dwelling type: Mid-terrace house LONDON Date of assessment: 10 February 2011 NW8 0ND Date of certificate: 11 February 2011 Reference number: 8908-4305-7529-9096-6293

More information

BER Assessors Dwellings Technical Bulletin

BER Assessors Dwellings Technical Bulletin BER Assessors Dwellings Technical Bulletin Issue No. 2/12 April 2012 Contents: 1. SUPPLEMENTARY ELECTRIC WATER HEATING IN SUMMER... 2 2. PITCHED ROOF U-VALUE CALCULATIONS... 8 2.1. PITCHED ROOF, INSULATED

More information

thermal cavity closers

thermal cavity closers thermal cavity closers cavity closers thermal bridging solutions from Manthorpe THERMAL BRIDGE THERMAL BREAK Poorly insulated door and window reveals can lead to significant heat loss and damp issues.

More information

Energy Performance Certificate

Energy Performance Certificate Energy Performance Certificate 10, Northfleet Road Eccles MANCHESTER M30 7PQ Dwelling type: Semi-detached house Date of assessment: 11 February 009 Date of certificate: 1 February 009 Reference number:

More information

Characterisation of dwellings in the UK determining the potential for enhanced energy efficiency Part of the BRE Trust

Characterisation of dwellings in the UK determining the potential for enhanced energy efficiency Part of the BRE Trust John Riley & Jack Hulme BRE 29 th February 2012 TABULA European Building Typologies Characterisation of dwellings in the UK determining the potential for enhanced energy efficiency Part of the BRE Trust

More information

exceed your energy performance levels

exceed your energy performance levels exceed your energy performance levels www..ie discover the better way to build Welcome to Thermohouse Thermohouse is one of the highest quality low energy building system available in Europe today. Thermohouse

More information

(1) WALLS:- INSULATION IN CAVITY Ground Floor - Insulation above slab DETAIL 1.01a, 2011 AIR BARRIER - CONTINUITY THERMAL PERFORMANCE GENERAL NOTES

(1) WALLS:- INSULATION IN CAVITY Ground Floor - Insulation above slab DETAIL 1.01a, 2011 AIR BARRIER - CONTINUITY THERMAL PERFORMANCE GENERAL NOTES (1) WALLS:- INSULATION IN CAVITY Ground Floor - Insulation above slab DETAIL 1.01a, 2011 THERMAL PERFORMANCE CHECKLIST (TICK ALL) AIR BARRIER - CONTINUITY CHECKLIST (TICK ALL) Ensure partial fill insulation

More information

Green Build Timber Frame. Helping you build a greener future

Green Build Timber Frame. Helping you build a greener future Timber Frame Helping you build a greener future Timber Frame Helping you build a greener future Today s homes demand a reliable, robust, high thermal performance building envelope, which drives energy-efficiency,

More information

the benefits of an energy efficient home GUIDE TO ENERGY EFFICIENCY TERMS Helping you understand the jargon.

the benefits of an energy efficient home GUIDE TO ENERGY EFFICIENCY TERMS Helping you understand the jargon. the benefits of an energy efficient home GUIDE TO ENERGY EFFICIENCY TERMS Helping you understand the jargon. ECONOMIC TERMS Sometimes terms used in energy efficiency can be confusing. This is a guide to

More information

FABRIC ENERGY EFFICIENCY FOR PART L 2013

FABRIC ENERGY EFFICIENCY FOR PART L 2013 Informing the Part L 2013 consultation FABRIC ENERGY EFFICIENCY FOR PART L 2013 WORKED EXAMPLES AND FABRIC SPECIFICATIONS February 2012 Introduction This report has been produced by the Zero Carbon Hub

More information

East Renfrewshire Local Development Plan LDP L O C A L DEVELOPMENT P L A N. June 2015

East Renfrewshire Local Development Plan LDP L O C A L DEVELOPMENT P L A N. June 2015 LDP L O C A L DEVELOPMENT P L A N East Renfrewshire Local Development Plan Supplementary Planning Guidance: Energy Efficient Design June 2015 Planning Property and Regeneration Supplementary Planning

More information

Energy Performance Certificate

Energy Performance Certificate Energy Performance Certificate Rhanleta Cottage Woolsery BIDEFORD EX39 5QP Dwelling type: Detached bungalow Date of assessment: 15 July 2009 Date of certificate: 17 July 2009 Reference number: 0347-2845-6036-0991-7175

More information

URSA GLASSWOOL URSA Cavity Batts

URSA GLASSWOOL URSA Cavity Batts Cavity Batts 065_Layout 1 13/07/2015 14:43 Page 1 UK LTD Crest House 102-104 Church Road Teddington, Middlesex TW11 8PY United Kingdom Tel : 020 8977 96 97 Fax : 020 8977 94 56 Web : www.ursa-uk.co.uk

More information

Energy Efficiency of Timber Frame Housing Bill Quigley 1

Energy Efficiency of Timber Frame Housing Bill Quigley 1 Wood Processing and Product Development No. 3 Energy Efficiency of Timber Frame Housing Bill Quigley 1 Kyoto Protocol 1997 It is widely accepted by the scientific community that the emission of the so-called

More information

Energy Performance Certificate

Energy Performance Certificate Energy Performance Certificate 7, Northfield Road SHEFFIELD S10 1QP Dwelling type: End-terrace house Date of assessment: 3 August 2009 Date of certificate: 3 August 2009 Reference number: 8311-6628-6400-5587-2002

More information

Rev 1-12.2013. Code of Practice. SIP Technology. www.uksips.org

Rev 1-12.2013. Code of Practice. SIP Technology. www.uksips.org Rev 1-12.2013 Code of Practice SIP Technology www.uksips.org What are Structural Insulated Panels (SIPS)? SIPS are prefabricated, high performance, lightweight, building panels that can be used in floors,

More information

Energy Performance Certificate

Energy Performance Certificate Trebarwith, St. Martins Lane, CREDITON, EX17 2DR Dwelling type: Detached house Reference number: 9268-3043-7264-4846-0960 Date of assessment: 16 April 2016 Type of assessment: RdSAP, existing dwelling

More information

Weather-tightness A Review of Exterior Wall Assemblies

Weather-tightness A Review of Exterior Wall Assemblies Weather-tightness A Review of Exterior Wall Assemblies Guy Cavanagh Engineer Marketing Innovision, Carter Holt Harvey Background The building industry in New Zealand is in an environment of panic over

More information

Building Control Guidance Note

Building Control Guidance Note Elements Renovation / Replacement. Issued 25/01/13 Rev a Page 1 of 9 (Applies to both Domestic and Non-Domestic Premises) Works relating to thermal elements can arise in building an extension, a material

More information

Ecojoist. Practical benefits of Ecojoist. www.eleco.com/gang-nail

Ecojoist. Practical benefits of Ecojoist. www.eleco.com/gang-nail Ecojoist Practical benefits of Ecojoist. www.eleco.com/gang-nail Gang-Nail Systems, an Eleco plc company, offer integrated solutions f the timber engineering industry which assist in reducing design, production

More information

Design of an Eco Friendly and Self Sufficient Cabin

Design of an Eco Friendly and Self Sufficient Cabin Design of an Eco Friendly and Self Sufficient Cabin This project is a real programme which is to develop a prototype of an eco friendly cabin. In this project, I choose two sites, Aberdeen and Brighton,

More information

Energy Performance Certificate

Energy Performance Certificate Energy Performance Certificate 60, Lon-y-Celyn CARDIFF CF14 7BW Dwelling type: Top floor flat Date of assessment: 7 May 2009 Date of certificate: 7 May 2009 Reference number: 8311-6525-6680-8103-9002 Total

More information

Energy Efficient Windows

Energy Efficient Windows Energy Efficient Windows All properties lose heat through their windows. But energy-efficient glazing keeps your home warmer and quieter as well as reducing your energy bills. That might mean double or

More information

Thermablok Aerogel Insulation Blanket Thermablok Aerogel Blanket

Thermablok Aerogel Insulation Blanket Thermablok Aerogel Blanket Uniclass 68152 Thermablok Aerogel Insulation Blanket Ultra Thin Internal Solid Wall, Ceiling & Floor Insulation Systems for New Build & Refurbishment Unique insulation with the lowest Thermal Conductivity

More information

Section 5.0. Basements. Wall insulated externally. Wall insulated internally. Ba02. Product: Polyfoam ECO Floorboard Ba01.

Section 5.0. Basements. Wall insulated externally. Wall insulated internally. Ba02. Product: Polyfoam ECO Floorboard Ba01. Section 5.0 Basements Wall insulated externally Product: Polyfoam ECO Ba01 Wall insulated internally Product: Polyfoam ECO Ba02 Basements Basements Basement design Waterproofing BS 8102: 2009 Code of practice

More information

Module 3.8. Window U-value

Module 3.8. Window U-value Module 3.8 Window U-value Learning Outcomes On successful completion of this module learners will be able to - Describe the concept of U-values and alternative energy rating system for windows. 2 Calculation

More information

ISOVER Pitched Roof Solutions. PART L TGD F1 Compliant. Insulation, Airtightness and Moisture Management Solutions for Timber Frame Roof Structures

ISOVER Pitched Roof Solutions. PART L TGD F1 Compliant. Insulation, Airtightness and Moisture Management Solutions for Timber Frame Roof Structures Want to know more? See our Metac video ISOVER Pitched Roof Solutions Insulation, Airtightness and Moisture Management Solutions for Timber Frame Roof Structures PART L TGD F1 Compliant ISOVER Saint Gobain

More information

The Kingspan Insulation Price List 1 st January 2013

The Kingspan Insulation Price List 1 st January 2013 Insulation The Kingspan Insulation Price List 1 st January 2013 FOR BUILDING FABRIC INSULATION, CAVITY CLOSERS AND MEMBRANES Visit our website: www.kingspaninsulation.co.uk Low Energy - Low Carbon Buildings

More information

WALLS Three common wall types are described below, with their insulation solutions.

WALLS Three common wall types are described below, with their insulation solutions. APPENDIX 5: Building Envelope Insulation is vitally important for temperature controlled buildings. If fuel (and therefore money) is being used to heat a building, less fuel (and money) will be used if

More information

Energy Performance Certificate

Energy Performance Certificate Energy Performance Certificate Flat 8 Ravenscourt 108-114, Richmond Road CARDIFF CF24 3BW Dwelling type: Ground floor flat Date of assessment: 26 June 2009 Date of certificate: 28 June 2009 Reference number:

More information

Energy Performance Certificate

Energy Performance Certificate Energy Performance Certificate North Cottage Dwelling type: End-terrace house Middlebere Farm Date of assessment: 03 May 011 Arne Date of certificate: 04 May 011 WAREHAM Reference number: 0584-867-655-9309-4361

More information

Energy Performance Certificate

Energy Performance Certificate Energy Performance Certificate 0 Raleigh Drive CULLOMPTON EX15 1FZ Dwelling type: Date of assessment: Date of certificate: Reference number: Type of assessment: Total floor area: Semi detached house 09

More information

Environmentally-Friendly Building Products from Renewable Resources. Product range overview. We care about. natural building products

Environmentally-Friendly Building Products from Renewable Resources. Product range overview. We care about. natural building products Environmentally-Friendly Building Products from Renewable Resources Product range overview We care about natural building products Wood and Hemp Nature s Eternal Gifts As a sustainable building material,

More information

Energy Performance Certificate

Energy Performance Certificate Energy Performance Certificate Address of dwelling and other details 4F1 27 EAST PRESTON STREET EDINBURGH EH8 9QE This dwelling's performance ratings Dwelling type: Top-floor flat Name of approved organisation:

More information

GREEN HARMONY HOME: UP TO 90 % ENERGY SAVING!

GREEN HARMONY HOME: UP TO 90 % ENERGY SAVING! YOUR GUIDE TO BUILDING AN ENERGY EFFICIENT HOME GREEN HARMONY HOME: UP TO 90 % ENERGY SAVING! Rewable green energy Site selection Form & orientation Efficient electric devices GREEN HARMONY HOME Super

More information

Use each of the terms in the box to explain how heat is lost from inside a house through the window. conduction convection radiation

Use each of the terms in the box to explain how heat is lost from inside a house through the window. conduction convection radiation Q. The diagram shows a side view of a double-glazed window. (a) Use each of the terms in the box to explain how heat is lost from inside a house through the window. conduction convection radiation..................

More information

Part L1B & What you need to know to get your building to pass. Mike Andrews DipNDEA, DipDEC, DipOCDEA, DipHI

Part L1B & What you need to know to get your building to pass. Mike Andrews DipNDEA, DipDEC, DipOCDEA, DipHI Part L1B & What you need to know to get your building to pass. Mike Andrews DipNDEA, DipDEC, DipOCDEA, DipHI The Building Regulations Part L1B what they are, how they affect your building design, and what

More information

Energy Performance Certificate

Energy Performance Certificate Energy Performance Certificate 51, Peabody Cottages Rosendale Road LONDON SE24 9DW Dwelling type: Ground floor maisonette Date of assessment: 10 December 2008 Date of certificate: 11 December 2008 Reference

More information

Energy Performance Certificate

Energy Performance Certificate 1 Brynsyfnai, Gelli Hill, Llawhaden, NARBERTH, SA67 8DL Dwelling type: end-terrace house Reference number: 8208-7130-6829-1307-3573 Date of assessment: 07 May 2013 Type of assessment: RdSAP, existing dwelling

More information

BER Assessors Dwellings Technical Bulletin

BER Assessors Dwellings Technical Bulletin BER Assessors Dwellings Technical Bulletin Issue No. 3/11 May 2011 Contents: 1 Window defaults in DEAP and use of DEAP Table 6a... 2 2 Solar Space Heating Systems in DEAP... 4 3 Storage and direct electric

More information

Low Carbon Domestic Refurbishment

Low Carbon Domestic Refurbishment www.breeam.com Briefing Paper Low Carbon Domestic Refurbishment Kiruthiga Balson, Gavin Summerson and Steven Stenlund 2 BRE Global Ltd 2014 Permission is granted for this report to be distributed only

More information

Energy Performance Certificate

Energy Performance Certificate Energy Performance Certificate 5 Queens Acre House Queens Acre WINDSOR SL4 2BE Dwelling type: Ground floor flat Date of assessment: 2 March 2009 Date of certificate: 2 March 2009 Reference number: 0828-3057-6207-5881-5020

More information

Conservatory warm roof conversion system

Conservatory warm roof conversion system Conservatory warm roof conversion system IS YOUR EXISTING CONSERVATORY ROOF: Too hot in summer or too cold in winter? Waste of valuable living space? Unable to relax to watch TV? Transform your conservatory

More information

Roof Insulation Systems. Kohler and Lewis Technical Note 2 of 5

Roof Insulation Systems. Kohler and Lewis Technical Note 2 of 5 Residential Building Insulation Systems for Cold Climates Joseph T. Kohler, Ph.D., P.E. November 6, 2003 There are many opinions regarding what constitutes the best insulation system for a wood framed

More information

Energy Performance Certificate

Energy Performance Certificate Energy Performance Certificate 35, Chapman Way HAYWARDS HEATH RH16 4UL Dwelling type: Date of assessment: Date of certificate: Reference number: Type of assessment: Total floor area: Top floor flat 8 June

More information

Environmentally-Friendly Building Products from Renewable Resources. We care about INT. natural building products

Environmentally-Friendly Building Products from Renewable Resources. We care about INT. natural building products Environmentally-Friendly Building Products from Renewable Resources We care about INT Wood and Hemp Nature s Eternal Gifts As a sustainable building material, wood is known for its excellent qualities,

More information

Information for the Supply Chain on Green Deal Measures. Version 1

Information for the Supply Chain on Green Deal Measures. Version 1 Information for the Supply Chain on Green Deal Measures Version 1 January 2013 Contents Introduction... 3 Introduction to the links between Green Deal measures and the Green Deal assessment tools... 4

More information

through wall and underfloor ventilation

through wall and underfloor ventilation through wall and underfloor ventilation through wall and underfloor ventilation Sub floor and cavity wall ventilation from Manthorpe The push for thermally efficient homes has led to increasing amounts

More information

L2B. Approved. Document. Existing buildings other than dwellings. The Building Regulations Conservation of fuel and power

L2B. Approved. Document. Existing buildings other than dwellings. The Building Regulations Conservation of fuel and power The Building Regulations 2010 Conservation of fuel and power Approved L2B Document Existing buildings other than dwellings Coming into effect July 2014 For use in Wales* Main changes in the 2014 edition

More information