SIRIUS Controls Contactors and Contactor Assemblies

Size: px
Start display at page:

Download "SIRIUS Controls Contactors and Contactor Assemblies"

Transcription

1 SIRIUS Controls Contactors and Contactor Assemblies / Introduction RT Power Contactors for Switching Motors / General data /5 RT0 contactors, -pole,... 5 HP RA, RA4 Contactor Assemblies RA Reversing Contactor Assemblies /8 RA complete units,... 5 HP /4 Components for customer assembly RA4 Contactor Assemblies for Wye- Delta Starting /6 RA4 complete units, kw /4 Components for customer assembly RT, RH Contactors for Special Applications RT Contactors for Switching Resistive Loads (AC-1) /45 4-pole, 4 NO, A RT5 Contactors /49 4-pole, NO + NC, HP Contactors with Extended Operating Range U s, for Railway Applications /5 RH1 contactor relays /55 RT0 motor contactors, HP Accessories and Spare Parts For RT, RH Contactors and Contactor Relays /89 General data /9 Auxiliary switch blocks /98 Auxiliary switch blocks, delayed /99 Delay and latching blocks /100 Surge suppressors /101 Other function blocks /10 Terminals, covers, adapters, connectors /105 Accessories /110 Spare parts for RT contactors Technical Information can be found at support under Product List: - Technical specifications under Entry List: - Updates - Download - FAQ - Manuals - Characteristics - Certificates and at configurators - Configurators RH Contactor Relays /58 RH contactor relays, 4- and 8-pole RH Control, Coupling Relays /67 RH4 latched control relays, 4-pole /68 RH1 coupling relays for switching auxiliary circuits, 4-pole RT Coupling Contactors /71 RT0 coupling contactors (interface) for switching motors, -pole,... 0 HP Function Modules for Mounting onto SIRIUS RT Contactors /76 Introduction /77 SIRIUS function modules /78 - For direct-on-line starting via parallel wiring /79 - For reversing starting / wye-delta starting /81 Function modules for IO-Link /85 Function modules for AS-Interface

2 SIRIUS Controls Contactors and Contactor Assemblies Introduction Overview Size Type RT0 contactors S00 RT0 1 S0 RT0 Type RT0 15 RT0 16 RT0 17 RT0 18 RT0 RT0 4 RT0 5 RT0 6 RT0 7 RT0 8 AC, DC operation (p. /8, /1) (p. /10, /14) Type UL/CSA General Use A I e /AC-/400 V A V HP /40 V 80/415 V 440/480 V 550/600 V AC-4 (for I a = 6 x I e ) HP HP HP HP V kw V kw ( operating cycles) AC-1 (40 C, 690 V) I e RT0 A Accessories for contactors Auxiliary switch blocks front RH9 11 (p. /9) RH9 11 (p. /9) lateral RH9 11 RH9 1 (p. /96) Timing relay blocks RA8 1. (p. /78) RA8 1. (p. /78) Function modules RA AA00 (p. /8, /87) RA AA00 (p. /8, /87) Surge suppressors RT9 16 (p. /100) RT9 6 (p. /100) RU and RB overload relays (Protection Equipment --> Overload Relays) RU1, thermal, CLASS 10 RU A (Chap. 5) RU A (Chap. 5) RB0/1, solid-state, CLASS 5, 10, 0 and 0 RB0 16 RB A (Chap. 5) RB0 6 RB1 RV0 motor starter protectors (Protection Equipment --> Motor Starter Protectors) A (Chap. 5) Type RV A (Chap. 5) RV A (Chap. 5) Link modules RA9 11 (Chap. 5) RA9 1 (Chap. 5) RA reversing contactor assemblies Complete units Type RA 15 RA 16 RA 17 RA RA 4 RA 5 RA 6 RA 7 RA 8 (p. /1) (p. /) 460 V HP Assembly kits/wiring modules RA9 1-AA. (p. /4) -- RA9 -AA. (p. /4) Function modules RA BA00 (p. /5) -- RA BA0 (p. /5) RA4 contactor assemblies for wye-delta starting Complete units Type RA4 15 RA4 16 RA4 17 RA4 RA4 5 RA4 6 (p. /9) (p. /41) 400 V kw /18.5 Assembly kits/wiring modules RA9 1-BB. (p. /4) RA9 -BB. (p. /4) Function modules RA CA00 (p. /44) RA CA00 (p. /44) /

3 RT Power Contactors for Switching Motors Overview The SIRIUS controls family The SIRIUS modular system with its components for the switching, starting, protection and monitoring of motors and industrial systems stands for the fast, flexible and space-saving construction of control cabinets. RT contactors and coupling contactors Size S00 with mountable accessories General data NSB0_0056a Contactor size S00 1-pole auxiliary switch block, laterally mountable 1-pole auxiliary switch block, for snapping onto the front Cable entry from the top 4 -pole auxiliary switch block, for snapping onto the front Cable entry from the bottom 5 4-pole auxiliary switch block, for snapping onto the front 6 RA8 function module 7 RA7 function module for AS-Interface, direct starting 8 RA7 function module for IO-Link, direct starting 9 Surge suppressor with/without LED 10 Three-phase feeder terminal For contactor assemblies see pages /8 to /44. For assembly kit for reversing contactor assemblies (mech. interlocking, wiring modules) see page /4. For function modules see pages /77 to /87. For accessories see pages /9 to / Star jumper, -pole, without terminal 1 Link for paralleling, -pole, with terminal 1 Wiring modules, on the top and bottom (reversing duty) Solder pin adapter Connection module (adapter and connector) for contactors with screw-type connection Safety main current connectors for two contactors For contactors For contactors and coupling contactors (interface) For mountable overload relays see Chapter 5 "Protection Equipment --> Overload Relays". For motor starters see Chapter 6 " Motor Starters" --> "RA Motor Starters". /

4 RT Power Contactors for Switching Motors General data RT contactors Size S0 with mountable accessories Contactor size S0 1-pole auxiliary switch block, laterally mountable 1-pole auxiliary switch block, for snapping onto the front Cable entry from the top 4 4-pole auxiliary switch block, for snapping onto the front 5 -pole auxiliary switch block, for snapping onto the front Cable entry from the bottom 6 Surge suppressor with/without LED 7 RA7 function module for AS-Interface, direct starting 8 RA8 function module 9 RA7 function module for IO-Link, direct starting 10 Pneumatic delay block /4 11 Mechanical latching block 1 Link for paralleling, -pole, with terminal 1 Connection module (adapter and plug) for contactors with screw-type connection 14 Coil terminal module, on the top and bottom 15 Wiring modules, on the top and bottom (reversing duty) 16 Three-phase feeder terminal 17 Link for paralleling (star jumper), -pole, without connection terminal 18 Safety main current connectors for two contactors NSB0_0057a 14 7

5 RT Power Contactors for Switching Motors RT0 contactors, -pole,... 5 HP Overview Sizes S00 and S0, up to 5 HP Connection methods The RT contactors are available with screw connections, spring-type terminals or ring lug terminal connections. Screw terminals Spring-type terminals Ring lug terminal connection These connections are indicated in the corresponding tables by orange backgrounds. IEC , EN , IEC , EN IEC , EN (auxiliary switches) The RT contactors are climate-proof and are suitable and tested for use worldwide. If the devices are used in ambient conditions which deviate from common industrial conditions (EN "Stationary Use, Weather-Protected"), information must be obtained about possible restrictions with regard to the reliability and endurance of the device and possible protective measures. In this case contact our Technical Assistance. RT contactors are finger-safe according to EN The devices with ring terminal lug connection comply with degree of protection IP0 when fitted with the related terminal cover. Auxiliary contact complement Size S00 contactors have an auxiliary contact integrated in the basic unit. The basic units size S0 contain two integrated auxiliary contacts (1 NO + 1 NC). All basic units (excluding coupling contactors) can be expanded with auxiliary switch blocks. For size S0 and higher, complete units with NO + NC are available (terminal designation according to EN 5001). The auxiliary switch block can be removed. A maximum of 4 additional auxiliary contacts can be attached; the auxiliary switch blocks used can be of any version. Of the maximum number of auxiliary contacts possible on the device (integrated plus mountable), four NC contacts are permitted in the case of contactor size S00 and four NC contacts in the case of contactor size S0. In addition, complete units with permanently mounted auxiliary switch block ( NO + NC according to EN 5001) are offered for sizes S00 and S0. Contact reliability If voltages 110 V and currents 100 ma are to be switched, the auxiliary contacts of the RT contactor or RH1 contactor relay should be used as they guarantee a high level of contact reliability. These auxiliary contacts are suitable for solid-state circuits with currents 1 ma at a voltage 17 V. Short-circuit protection of the contactors For short-circuit protection of the contactors without overload relay see "More Information" (pages /0, /). For short-circuit protection of the contactors with overload relay see Chapter 5 "Overload Relays". To assemble motor starters you must select combinations of motor starter protector and contactor as explained in "RA Motor Starters" (see Chapter 6). Motor protection RU1 thermal overload relays or RB0 solid-state overload relays can be fitted to the RT contactors for protection against overload. The overload relays must be ordered separately (see Chapter 5). Ratings of induction motors The quoted rating (in HP) refers to the output power on the motor shaft (according to the motor nameplate). Control supply voltage All contactors are available with AC or DC operation. For contactors of size S0, a UC operating mechanism is also available which allows for operation with both AC (45 to 70 Hz) and with DC. Surge suppression RT contactors can be retrofitted with RC elements, varistors, suppressor diodes or diode assemblies (assembly of diode and Zener diode for short break times) for damping opening surges in the coil. The surge suppressors are plugged onto the front of size S00 contactors. Space is provided for them next to a snap-on auxiliary switch block. The surge suppressors can be plugged onto the front of size S0 contactors. Note: The OFF-delay of the NO contact and the ON-delay of the NC contact are increased if the contactor coils are attenuated against voltage peaks (noise suppression diode 6 to 10 times; diode assemblies to 6 times, varistor and suppressor diode + to 5 ms). S00 and S0 contactors with communication interface The S00 and S0 contactors with communication interface are essential for mounting the SIRIUS function modules for connection to the control system through IO-Link or AS-Interface (see page /81 and /85). Further information on IO-Link and AS-Interface can be found in Chapter "Industrial Communication". /5

6 RT Power Contactors for Switching Motors RT0 contactors, -pole,... 5 HP scheme Digit of the SIRIUS R T nd generation Device type (e. g. 0 = -pole motor contactor, = 4-pole AC-1 contactor) Contactor size (1 = S00, = S0) Power dependent on size (e. g. 7 = 0 HP) Connection type (1 = screw, = spring, 4 = ring lug) Operating range / solenoid coil circuit (e. g. A = AC standard / without) Rated control supply voltage (e. g. K6 = 10 V, Auxiliary switches (e. g. S0: 0 = 1 NO + 1 NC integrated) Special version Example R T A K 6 0 Note: The scheme is presented here merely for information purposes and for better understanding of the logic behind the For your orders, please use the order numbers quote in the catalog in the Selection and ordering data. Accessories Auxiliary switch blocks Various auxiliary switch blocks can be added to the RT basic units depending on the application: Size S00, RT0 1. contactors Terminal designations according to EN 5001 or EN Size S00 contactors have an auxiliary contact (NO or NC) integrated in the basic unit. Contactors, EN 5001, 1 aux. contact Ident. No. 10E Aux. switch blocks, EN 5001, 4, or 1 contacts Ident. No. E, E, E, 11E Contactors, EN , 4 or aux. contacts Ident. No. 01 Aux. switch blocks, EN 50005, 4 or contacts Ident. No. 40, 1,, 0, 11, 0, 0, 04 Contactors, EN 50005, 5 or aux. contacts Contactors with a NO contact as auxiliary contact with screw or spring-type terminals and ring lug terminal connection, identification number 10E, can be expanded into contactors with,, 4 and 5 auxiliary contacts according to EN 5001 using auxiliary switch blocks. The identification numbers according to EN 5001, e. g. 11E, apply to the basic device plus mounted auxiliary switch. All contactors of size S00 with one auxiliary contact (identification numbers 10E or 01) and the contactors with 4 main contacts can be expanded into contactors with to 5 auxiliary contacts using auxiliary switch blocks with the identification numbers 40 to 04 (in the case of contactors with 4 main contacts: 1 to 4 auxiliary contacts) according to EN Of the auxiliary contacts (integrated plus mountable) possible on the device, no more than four NC contacts are permitted. Single- or -pole auxiliary switch blocks with connection options from above or below enable easy and clearly arranged wiring especially for the installation of network access junctions. These auxiliary switch blocks are offered only with screw terminals. If the installation space is limited in depth, -pole auxiliary switch blocks (screw or spring-type terminals and ring terminal lug connection) can be attached laterally for use on the right or on the left. The solid-state compatible RH9 1.-1NF.. auxiliary switch blocks for contactors of size S00 include enclosed contacts. They are suitable in particular for switching small voltages and currents (hard gold-plated contacts) and for operation in dusty atmospheres. The NC auxiliary contacts are not mirror contacts. All the previously mentioned auxiliary switch variants can be snap-fitted onto the front of the contactor. The auxiliary switch block has a centrally positioned release lever for disassembly. Ident. No. E, E, E, 11E NSB0_006a Ident. No. 40, 1,, 0, 11, 0, 0, 04 Contactor, size S00, with 4-pole auxiliary switch block /6

7 RT Power Contactors for Switching Motors RT0 contactors, -pole,... 5 HP Size S0, RT0. contactors Terminal designations according to EN or EN Size S0 contactors have auxiliary contacts (1 NO and 1 NC) integrated in the basic unit.. Aux. switch blocks with 4 contacts, RH9 1-. FA.., RH9 1-. HA.. acc. to EN Ident. No. contactors RT0. with 1 NO + 1 NC U, 11U 0, 1, 1, 0, 11, 0, 10, 01 Possible complements of contactors with 4-pole aux. switch blocks, terminal designations acc. to EN Ident. No. 11+U, 11+11U 41,,, 1,, 1, 1, 1 NSB0_006a Aux. switch blocks with contacts, RH9 1-. HA.. acc. to EN Ident. No. 0, 1, 1, 0, 11, 0, 10, 01 Possible complements of contactors with 4-pole aux. switch blocks, terminal designations acc. to EN Ident. No. 41,,, 1,, 1, 1, 1 Also available are 1- or -pole auxiliary switch blocks (screw terminals) for cable entry from above or below in the design of a quad block (feeder auxiliary switch). If the installation space is limited in depth, -pole auxiliary switch blocks (screw or spring-type terminals and ring lug terminal connection) can be attached laterally for use on the right or on the left. The auxiliary switch blocks attached to the front can be disassembled with the help of a centrally arranged release lever; the laterally attached auxiliary switch blocks are easy to remove by pressing on the checkered surfaces. The terminal designation of the individual auxiliary switch blocks corresponds to EN or EN 5001, that of the complete contactor with auxiliary switch block NO + NC corresponds to EN The laterally mountable auxiliary switch blocks according to EN 5001 can be used only when no 4-pole auxiliary switch blocks are snapped onto the front. As auxiliary contacts 1 NO + 1 NC are already integrated in the basic device, mounting according to EN 5001 is permitted only on the right of the device. The front 1- or -pole auxiliary switch blocks with connection option from below or above have fixed location identifiers. These auxiliary switch blocks are available only with screw terminals. If the 4-pole and solid-state compatible auxiliary switch blocks are used, the location identifiers on the basic device must be noted. Two enclosed contacts are available with the RH9 11-.NF11 solid-state compatible auxiliary switch block, which can be attached to the front. The RH9 1-DE11 laterally mountable, solid-state compatible auxiliary switch block also contains enclosed contacts (1 NO + 1 NC). The enclosed contacts are suitable in particular for switching small voltages and currents (hard gold-plated contacts) and for operation in dusty atmospheres. The front NC auxiliary contacts are not mirror contacts. A maximum of 4 auxiliary contacts can be attached; the auxiliary switch blocks used can be of any version. Of the auxiliary contacts (integrated plus mountable) possible on the device, no more than four NC contacts are permitted however. For 4-pole contactors see RT and RT5. Contactor, size S0, with 4-pole auxiliary switch block A diverse range of auxiliary switch blocks is available for various applications. One 4-pole auxiliary switch block (screw or spring-type terminals and ring lug terminal connection) can be snapped onto the front of the contactors. When the contactors are switched on, the NC contacts are opened first and then the NO contacts are closed. /7

8 RT Power Contactors for Switching Motors RT0 contactors, -pole,... 5 HP Selection and ordering data Size S00 AC Operation RTRT A... RT0 1. -A... AC data UL/CSA data Screw terminals Weight Amp ratings UL/CSA General Use Single-phase HP ratings Three-phase HP ratings Auxiliary contacts Rated control supply voltage U s at 50/60 Hz Spring-type terminals AC 115 V 0 V 00 V 0 V 460 V 575 V Ident NO NC V AC kg No. For screw and DIN Rail mounting onto TH 5 standard mounting rail Size S00 1) Terminal designations according to EN 5001 or EN With auxiliary contact 1 NO, identification number 10 E With auxiliary contact 1 NC, identification number 01 )! #!! )! #! ) ` 6 " 6 $ 6! " ) ` 6 " 6 $ 6! 7 0 1/4 /4 1 1/ 5 10E RT0 15-@AB01 0.8/ /4 /4 1 1/ 5 10E /10 RT0 15-@AK61 0.8/ /4 /4 1 1/ 5 10E /40 RT0 15-@AP61 0.8/ /4 /4 1 1/ RT0 15-@AB0 0.8/ /4 /4 1 1/ /10 RT0 15-@AK6 0.8/ /4 /4 1 1/ /40 RT0 15-@AP6 0.8/ / / 10E RT0 16-@AB01 0.8/ / / 10E /10 RT0 16-@AK61 0.8/ / / 10E /40 RT0 16-@AP61 0.8/ / / RT0 16-@AB0 0.8/ / / /10 RT0 16-@AK6 0.8/ / / /40 RT0 16-@AP6 0.8/ / 7 1/ 10 10E RT0 17-@AB01 0.8/ / 7 1/ 10 10E /10 RT0 17-@AK61 0.8/ / 7 1/ 10 10E /40 RT0 17-@AP61 0.8/ / 7 1/ RT0 17-@AB0 0.8/ / 7 1/ /10 RT0 17-@AK6 0.8/ / 7 1/ /40 RT0 17-@AP6 0.8/ E RT0 18-@AB01 0.8/ E /10 RT0 18-@AK61 0.8/ E /40 RT0 18-@AP61 0.8/ RT0 18-@AB0 0.8/ /10 RT0 18-@AK6 0.8/ /40 RT0 18-@AP6 0.8/0.0 Screw terminals 1 Spring-loaded terminals Ring lug terminals 4 AC data UL data Screw terminals Weight Amp ratings Single-phase HP ratings Three-phase HP ratings Auxiliary contacts NEMA Size AC AC1 115 V 0 V 00 V 0 V 460 V 575 V Ident No. NO NC kg NEMA Labeled Contactors ) E RT0 18-1AK61-0UA For other voltages see page /17. For contactors with permanently mounted auxiliary switch block see pages /9, /11, /1, /15.For accessories and spare parts, see page /9. 1) For coil operating range, see page /17. ) NEMA labeled Contactor has 110/10 V AC control with screw terminals. /8 Illustrations are approximate

9 RT Power Contactors for Switching Motors Size S00 AC Operation Contactors with Permanently Mounted Aux Switch Block RT0 contactors, -pole,... 5 HP RT AK64-MA0 RT0 1. -AK64-MA0 AC data UL/CSA data Screw terminals Weight Amp ratings UL/CSA General Use Single-phase HP ratings Three-phase HP ratings Auxiliary contacts Rated control supply voltage U s at 50/60 Hz Spring-type terminals AC 115 V 0 V 00 V 0 V 460 V 575 V Ident NO NC V AC kg No. For screw and DIN Rail mounting onto TH 5 standard mounting rail Size S00 1) With permanently mounted auxiliary switch block Terminal designations according to EN 5001 )! #!!! "! ) ` 6 " 6 $ 6! "! " " 7 0 1/4 /4 1 1/ 5 E 110/10 RT0 15-@AK64-MA0 0.8/ / / E 110/10 RT0 16-@AK64-MA0 0.8/ / 7 1/ 10 E 110/10 RT0 17-@AK64-MA0 0.8/ E 110/10 RT0 18-@AK64-MA0 0.8/0.0 With permanently mounted auxiliary switch block and varistor plugged into the front Terminal designations according to EN 5001 A1(+) 1/L1 /L 5/L A( ) /T1 4/T 6/T /4 /4 1 1/ 5 E 110/10 RT0 15-@CK64-MA0 0.8/ / / E 110/10 RT0 16-@CK64-MA0 0.8/ / 7 1/ 10 E 110/10 RT0 17-@CK64-MA0 0.8/ E 110/10 RT0 18-@CK64-MA0 0.8/0.0 Screw terminals 1 Spring-loaded terminals For other voltages see page /17. For other contactors with permanently mounted auxiliary switch block see pages /11, /1, /15. 1) For size S00: Coil operating range at 50 Hz: U s, at 60 Hz: U s. For accessories and spare parts, see page /9. Illustrations are approximate /9

10 RT Power Contactors for Switching Motors RT0 contactors, -pole,... 5 HP Size S0 AC Operation RT0. -1A..0 RT0. -A..0 AC data UL/CSA data Screw terminals Weight Amp ratings UL/CSA General Use Single-phase HP ratings Three-phase HP ratings Auxiliary contacts Rated control supply voltage U s at 50/60 Hz Spring-type terminals AC 115 V 0 V 00 V 0 V 460 V 575 V Ident NO NC V AC kg No. For screw and DIN Rail mounting onto TH 5 standard mounting rail Size S0 1)) Terminal designations according to EN 5001 or EN )! #!! ) ` 6 " 6 $ 6! " / 11E RT0 -@AC0 0.46/ / 11E /10 RT0 -@AK / / 11E 1 1 0/40 RT0 -@AP / / 10 11E RT0 4-@AC0 0.46/ / 10 11E /10 RT0 4-@AK / / 10 11E 1 1 0/40 RT0 4-@AP / E RT0 5-@AC0 0.46/ E /10 RT0 5-@AK / E 1 1 0/40 RT0 5-@AP / / 7 1/ E RT0 6-@AC0 0.46/ / 7 1/ E /10 RT0 6-@AK / / 7 1/ E 1 1 0/40 RT0 6-@AP / E RT0 7-@AC0 0.46/ E /10 RT0 7-@AK / E 1 1 0/40 RT0 7-@AP / E RT0 8-@AC0 0.46/ E /10 RT0 8-@AK / E 1 1 0/40 RT0 8-@AP /0.44 Screw terminals 1 Spring-loaded terminals Ring lug terminals 4 AC data UL data Screw terminals Weight Amp ratings Single-phase HP ratings Three-phase HP ratings AC AC1 115 V 0 V 00 V 0 V 460 V 575 V NEMA Labeled Contactors ) / 7 1/ E RT0 6-1AK60-0UA ) For coil operating range, see page /17. ) NEMA labeled Contactor has 110/10 V AC control with screw terminals. For other voltages see page /17. For contactors with permanently mounted auxiliary switch block see pages /9, /11, /1, /15. For accessories and spare parts, see page /9. Auxiliary contacts NEMA Size Ident No. NO NC kg /10 Illustrations are approximate

11 RT Power Contactors for Switching Motors Size S0 AC operation With Permanently Mounted Aux Switch RT0 contactors, -pole,... 5 HP RT0. -1AK64-MA0 RT0. -AK64-MA0 AC data UL/CSA data Screw terminals Weight Amp ratings UL/CSA General Use Single-phase HP ratings Three-phase HP ratings Auxiliary contacts Rated control supply voltage U s at 50/60 Hz Spring-type terminals AC 115 V 0 V 00 V 0 V 460 V 575 V Ident No. NO NC V AC kg For screw and DIN Rail mounting onto TH 5 standard mounting rail Size S0 ) With permanently mounted auxiliary switch block 1) Terminal designations according to EN /L1 /L 5/L A1(+) A( ) /T1 4/T 6/T / 11E /10 RT0 -@AK64-MA0 0.46/ / 10 11E /10 RT0 4-@AK64-MA0 0.46/ E /10 RT0 5-@AK64-MA0 0.46/ / 7 1/ E /10 RT0 6-@AK64-MA0 0.46/ E /10 RT0 7-@AK64-MA0 0.46/ E /10 RT0 8-@AK64-MA0 0.46/0.44 With permanently mounted auxiliary switch block and varistor plugged into the front Terminal designations according to EN 5001 A1(+) 1/L1 /L 5/L A( ) /T1 4/T 6/T / 11E /10 RT0 -@CK64-MA0 0.46/ / 10 11E /10 RT0 4-@CK64-MA0 0.46/ E /10 RT0 5-@CK64-MA0 0.46/ / 7 1/ E /10 RT0 6-@CK64-MA0 0.46/ E /10 RT0 7-@CK64-MA0 0.46/ E /10 RT0 8-@CK64-MA0 0.46/0.44 For other voltages see page /17. For other contactors with permanently mounted auxiliary switch block see pages /9, /1, /15. For accessories and spare parts, see page /9. 1) ) Screw terminals 1 Spring-loaded terminals No surge suppressors can be retrofitted. For coil operating range, see page /17. Illustrations are approximate /11

12 RT Power Contactors for Switching Motors RT0 contactors, -pole,... 5 HP Size S00 DC operation DC solenoid system RT B... RT0 1. -B... AC data UL/CSA data Screw terminals Weight Amp ratings UL/CSA General Single-phase HP ratings Three-phase HP ratings Auxiliary contacts Rated control supply Spring-type terminals Use voltage U s AC 115 V 0 V 00 V 0 V 460 V 575 V Ident No. NO NC V DC kg For screw and DIN Rail mounting onto TH 5 standard mounting rail Size S00 Terminal designations according to EN 5001 or EN With auxiliary contact 1 NO, identification number 10 E! #!! ) ) ` 6 " 6 $ 6! With auxiliary contact 1 NC, identification number /4 /4 1 1/ 5 10E RT0 15-@BB41 0.8/ /4 /4 1 1/ 5 10E RT0 15-@BG41 0.8/ /4 /4 1 1/ RT0 15-@BB4 0.8/ /4 /4 1 1/ RT0 15-@BG4 0.8/ / / 10E RT0 16-@BB41 0.8/ / / 10E RT0 16-@BG41 0.8/ / / RT0 16-@BB4 0.8/ / / RT0 16-@BG4 0.8/ / 7 1/ 10 10E RT0 17-@BB41 0.8/ / 7 1/ 10 10E RT0 17-@BG41 0.8/ / 7 1/ RT0 17-@BB4 0.8/ / 7 1/ RT0 17-@BG4 0.8/ E RT0 18-@BB41 0.8/ E RT0 18-@BG41 0.8/ RT0 18-@BB4 0.8/ RT0 18-@BG4 0.8/0.0 With integrated coil circuit (diode) Terminal designations according to EN 5001 With auxiliary contact 1 NO, identification number 10 E A1(+) A( ) 1/L1 /T1 /L 4/T " 5/L 6/T 1 14 )! #! ) ` 6 " 6 With auxiliary contact 1 NC, identification number 01 A1(+) A( ) 7 0 1/4 /4 1 1/ 5 10E RT0 15-@FB41 0.8/ /4 /4 1 1/ RT0 15-@FB4 0.8/ / / 10E RT0 16-@FB41 0.8/ / / RT0 16-@FB4 0.8/ / 7 1/ 10 10E RT0 17-@FB41 0.8/ / 7 1/ RT0 17-@FB4 0.8/ E RT0 18-@FB41 0.8/ RT0 18-@FB4 0.8/0.0 $ 6! 1/L1 /L 5/L 1 /T1 4/T 6/T For other voltages see page /17. For contactors with permanently mounted auxiliary switch block see pages /9, /11, /1, /15. For accessories and spare parts, see page /9. Screw terminals 1 Spring-loaded terminals Ring lug terminals 4 /1 Illustrations are approximate

13 RT Power Contactors for Switching Motors RT0 contactors, -pole,... 5 HP Size S00 DC operation DC solenoid system Permanently mounted Aux switch Communication contactors RT BB44-MA0 RT0 1. -BB44-MA0 RT B.4.-0CC0 RT0 1. -B.4.-0CC0 AC data UL/CSA data Screw terminals Weight Amp UL/CSA Single-phase Three-phase Auxiliary contacts Rated control Spring-type terminals ratings General Use HP ratings HP ratings supply voltage U s AC 115 V 0 V 00 V 0 V 460 V 575 V Ident No. NO NC V DC kg For screw and DIN Rail mounting onto TH 5 standard mounting rail Size S00 With permanently mounted auxiliary switch block Terminal designations according to EN 5001! #!! ) ) ` 6 " 6 $ 6! "! " " 7 0 1/4 /4 1 1/ 5 E 4 RT0 15-@BB44-MA0 0.8/ / / E 4 RT0 16-@BB44-MA0 0.8/ / 7 1/ 10 E 4 RT0 17-@BB44-MA0 0.8/ E 4 RT0 18-@BB44-MA0 0.8/0.0 With permanently mounted auxiliary switch block and integrated coil circuit (diode) Terminal designations according to EN 5001 A1(+) 1/L1 /L 5/L A( ) /T1 4/T 6/T /4 /4 1 1/ 5 E 4 RT0 15-@FB44-MA0 0.8/ / / E 4 RT0 16-@FB44-MA0 0.8/ / 7 1/ 10 E 4 RT0 17-@FB44-MA0 0.8/ E 4 RT0 18-@FB44-MA0 0.8/0.0 Contactors with communication interface 1) Terminal designations according to EN 5001 or EN With auxiliary contact 1 NO, identification number 10 E 1! #!! )! 1 "! 1 4 With auxiliary contact 1 NC, identification number 01 )! #! ) ` 6 " 6 $ 6! " ) ` 6 " 6 $ 6! 7 0 1/4 /4 1 1/ 5 10E RT0 15-@BB41-0CC0 0.8/ /4 /4 1 1/ RT0 15-@BB4-0CC0 0.8/ / / 10E RT0 16-@BB41-0CC0 0.8/ / / RT0 16-@BB4-0CC0 0.8/ / 7 1/ 10 10E RT0 17-@BB41-0CC0 0.8/ / 7 1/ RT0 17-@BB4-0CC0 0.8/ E RT0 18-@BB41-0CC0 0.8/ RT0 18-@BB4-0CC0 0.8/0.0 For other voltages see page /17. For other contactors with permanently mounted auxiliary switch block see pages /9, /11, /15. For accessories and spare parts, see page /9. 1) Screw terminals 1 Spring-loaded terminals For use with RA7 and RA8 communication modules. See Section and also page /76. Illustrations are approximate /1

14 RT Power Contactors for Switching Motors RT0 contactors, -pole,... 5 HP Size S0 DC operation DC solenoid system RT0. -1B. 40 RT0. -B. 40 AC data UL/CSA data Screw terminals Weight Amp ratings UL/CSA General Single-phase HP ratings Three-phase HP ratings Auxiliary contacts Rated control supply Spring-type terminals Use voltage U s AC 115 V 0 V 00 V 0 V 460 V 575 V Ident NO NC V DC kg No. For screw and DIN Rail mounting onto TH 5 standard mounting rail Size S0 Terminal designations according to EN 5001! #!! ) ) ` 6 " 6 $ 6! " / 11E RT0 -@BB / / 11E RT0 -@BG / / 10 11E RT0 4-@BB / / 10 11E RT0 4-@BG / E RT0 5-@BB / E RT0 5-@BG / / 7 1/ E RT0 6-@BB / / 7 1/ E RT0 6-@BG / E RT0 7-@BB / E RT0 7-@BG / E RT0 8-@BB / E RT0 8-@BG /0.6 With plugged-in coil circuit (diode assembly) Terminal designations according to EN 5001 A1(+) 1/L1 /L 5/L 1 1 A( ) /T1 4/T 6/T / 11E RT0 -@FB / / 10 11E RT0 4-@FB / E RT0 5-@FB / / 7 1/ E RT0 6-@FB / E RT0 7-@FB / E RT0 8-@FB /0.60 For other voltages see page /17. For contactors with permanently mounted auxiliary switch block see pages /9, /11, /1, /15. For accessories and spare parts, see page /9. Screw terminals 1 Spring-loaded terminals Ring lug terminals 4 /14 Illustrations are approximate

15 RT Power Contactors for Switching Motors RT0 contactors, -pole,... 5 HP Size S0 DC operation DC solenoid system Permanently mounted Aux switch Communication contactors RT0. -1BB44-MA0 RT0. -BB44-MA0 RT0.-1BB40-0CC0 RT0.-BB40-0CC0 AC data UL/CSA data Screw terminals Weight Amp UL/CSA Single-phase Three-phase Auxiliary contacts Rated control Spring-type terminals ratings General Use HP ratings HP ratings supply voltage U s AC 115 V 0 V 00 V 0 V 460 V 575 V Ident No. NO NC V DC kg For screw and DIN Rail mounting onto TH 5 standard mounting rail Size S0 With permanently mounted auxiliary switch block 1) Terminal designations according to DIN /L1 /L 5/L A1(+) A( ) /T1 4/T 6/T / E 4 RT0 -@BB44-MA0 0.58/ / 10 E 4 RT0 4-@BB44-MA0 0.58/ E 4 RT0 5-@BB44-MA0 0.58/ / 7 1/ 15 0 E 4 RT0 6-@BB44-MA0 0.58/ E 4 RT0 7-@BB44-MA0 0.58/ E 4 RT0 8-@BB44-MA0 0.58/0.6 With permanently mounted auxiliary switch block and plugged-in coil circuit (diode assembly) Terminal designations according to EN 5001 A1(+) 1/L1 /L 5/L A( ) /T1 4/T 6/T / E 4 RT0 -@FB44-MA0 0.58/ / 10 E 4 RT0 4-@FB44-MA0 0.58/ E 4 RT0 5-@FB44-MA0 0.58/ / 7 1/ 15 0 E 4 RT0 6-@FB44-MA0 0.58/ E 4 RT0 7-@FB44-MA0 0.58/ E 4 RT0 8-@FB44-MA0 0.58/0.6 Contactors with communication interface ) Terminal designations according to EN 5001! #!! ) ) ` 6 " 6 $ 6! " / 11E RT0 -@BB40-0CC0 0.58/ / 10 11E RT0 4-@BB40-0CC0 0.58/ E RT0 5-@BB40-0CC0 0.58/ / 7 1/ E RT0 6-@BB40-0CC0 0.58/ E RT0 7-@BB40-0CC0 0.58/ E RT0 8-@BB40-0CC0 0.58/0.6 For other voltages see page /17. For other contactors with permanently mounted auxiliary switch block see pages /9, /11, /1. For accessories and spare parts, see page /9. Screw terminals 1 Spring-loaded terminals 1) No surge suppressors can be retrofitted. ) For use with RA7 and RA8 communication modules. See Section and also page /76. Illustrations are approximate /15

16 RT Power Contactors for Switching Motors RT0 contactors, -pole,... 5 HP Size S0 UC operation AC or DC operation Extended operating range of the solenoid coils x U s Integrated coil circuit RT0. -1N. 0 RT0. -N. 0 AC data UL/CSA data Screw terminals Weight Amp UL/CSA Single-phase Three-phase Auxiliary contacts Rated control Spring-type terminals ratings General Use HP ratings HP ratings supply voltage U s AC 115 V 0 V 00 V 0 V 460 V 575 V Ident NO NC V AC/DC kg No. For screw and DIN Rail mounting onto TH 5 standard mounting rail Size S0 With integrated coil circuit (varistor) Terminal designations according to EN 5001 A1(+) 1/L1 /L 5/L 1 1 A( ) /T1 4/T 6/T / 11E RT0 -@NB0 0.55/ / 11E RT0 -@NF0 0.55/ / 11E ) RT0 -@NP0 0.55/ / 10 11E RT0 4-@NB0 0.55/ / 10 11E RT0 4-@NF0 0.55/ / 10 11E ) RT0 4-@NP0 0.55/ E RT0 5-@NB0 0.55/ E RT0 5-@NF0 0.55/ E ) RT0 5-@NP0 0.55/ / 7 1/ E RT0 6-@NB0 0.55/ / 7 1/ E RT0 6-@NF0 0.55/ / 7 1/ E ) RT0 6-@NP0 0.55/ E RT0 7-@NB0 0.55/ E RT0 7-@NF0 0.55/ E ) RT0 7-@NP0 0.55/ E RT0 8-@NB0 0.55/ E RT0 8-@NF0 0.55/ E ) RT0 8-@NP0 0.55/0.58 1) At 80 V: upper limit =1.1 x U s. For accessories and spare parts, see page /9. Screw terminals 1 Spring-loaded terminals /16 Illustrations are approximate

17 RT Power Contactors for Switching Motors Rated control supply voltages (the 10th and 11th position of the order number must be changed) RT0 contactors, -pole,... 5 HP Rated control supply Contactor type RT0 1 RT0 RT 1, voltage U s RT5 1 Size S00 S0 S00 S0 Sizes S00... S0 AC operation 1) Solenoid coils for 50 Hz (exception: Size S00: 50 and 60 Hz ) ) 4 V AC B0 B0 B0 B0 4 V AC D0 D0 D V AC H0 H0 H V AC F0 F0 F0 F0 0 V AC P0 P0 P0 P0 400 V AC V0 V0 V0 V0 Solenoid coils for 50 and 60 Hz ) 4 V AC B0 C B0 C 4 V AC D0 D D0 D 48 V AC H0 H H0 H 110 V AC F0 G F0 G 0 V AC N N N N 0 V AC P0 L P0 L 40 V AC P P P P Solenoid coils (for USA and Canada ) ) 50 Hz 60 Hz 110 V AC 10 V AC K6 K6 K6 K6 0 V AC 40 V AC P6 P6 P6 P V AC V6 V6 V6 V V AC T6 T6 T6 T6 Solenoid coils (for Japan) 50/60 Hz 4) 60 Hz 5) 100 V AC 110 V AC G6 G6 G6 G6 00 V AC 0 V AC N6 N6 N6 N6 400 V AC 440 V AC R6 R6 R6 R6 DC operation 1) 1 V DC A4 -- A V DC B4 B4 B4 B4 4 V DC D4 D4 D4 D4 48 V DC W4 W4 W V DC E4 E V DC F4 F4 F4 F4 15 V DC G4 G4 G4 G4 0 V DC M4 M4 M4 M4 0 V DC P4 P4 P4 -- Examples AC operation RT0-1AP00 Contactor with screw terminals; with solenoid coil for 50 Hz for rated control supply voltage 0 V AC. RT0-1AG0 Contactor with screw terminals; with solenoid coil for 50/60 Hz for rated control supply voltage 110 V AC. DC operation RT0 5-BB40 Contactor with spring-type terminals; for rated control supply voltage 4 V DC. RT0 5-BG40 Contactor with spring-type terminals; for rated control supply voltage 15 V DC. RT, RT5 Rated control supply Contactor type -- voltage U s min... U 6) s max Size S00 S0 Size S0 UC operation (AC 45 to 70 Hz, DC) V AC/DC -- B V AC/DC -- F V AC/DC 7) -- P 1) For deviating coil voltages and coil operating ranges of sizes S00 and S0, the 4 V DC SITOP Power power supply unit with wide range input (9 to 64 V AC; 0 to 64 V DC) can be used for coil excitation (see 010 Controls Catalog, Chapter 15, "SITOP Power Supplies"). ) Coil operating range at 50 Hz: x U s at 60 Hz: x U s. ) Coil operating range Size S00: at 50 Hz: x U s at 60 Hz: x U s Size S0: at 50 Hz and 60 Hz: x U s. RT..-.N 4) Coil operating range Size S00: at 50/60 Hz: x U s Size S0: at 50 Hz: x U s at 60 Hz: x U s. 5) Coil operating range at 60 Hz: x U s. 6) Coil operating range: 0.7 x U s min...1. x U s max. 7) At 80 V: upper limit =1.1 x U s. /17

18 RT Power Contactors for Switching Motors RT0 contactors, -pole,... 5 HP More information Contactors Type RT Size S00 and S0 Width mm 45 Rated data of the auxiliary contacts According to IEC /EN The data apply to integrated auxiliary contacts and contacts in the auxiliary switch blocks for contactor sizes S00 to S0 1) Rated insulation voltage U i (pollution degree ) V 690 Conventional thermal current I th = A 10 Rated operational current I e /AC-1 AC load Rated operational current I e /AC-15/AC-14 For rated operational voltage U e 4 V A 10 1) 110 V A 10 1) 15 V A 10 1) 0 V A 10 1) 0 V A 10 1) DC load Rated operational current I e /DC-1 80 V A 400 V A 500 V A 660 V A V A 1 For rated operational voltage U e 4 V A 6 60 V A V A 15 V A 0 V A V A V A 0.15 Rated operational current I e /DC-1 For rated operational voltage U e 4 V A 6 60 V A 110 V A 1 15 V A V A V A V A 0.1 Contact reliability at 17 V, 1 ma acc. to EN Endurance of the auxiliary contacts It is assumed that the operating mechanisms are switched randomly, i. e. not synchronized with the phase angle of the supply system. The contact endurance is mainly dependent on the breaking current. The characteristic curves apply to: Integrated auxiliary contacts on RT0 Auxiliary switch blocks RH 9 11, RH9 1 for contactors size S00 and S0. Frequency of contact faults <10-8 i. e. <1 fault per 100 million operating cycles NSB0_0061a I I I I I Diagram legend: I a = Breaking current I e = Rated operational current 1) Integrated auxiliary contacts in size S0, auxiliary switches for snapping onto the front and for mounting onto the side in size S00 and S0: I e = 6 A at AC-14/AC-15. /18

19 RT Power Contactors for Switching Motors RT0 contactors, -pole,... 5 HP Endurance of the main contacts The characteristic curves show the contact endurance of Size S00 the contactors when switching resistive and inductive AC Operating cycles at loads (AC-1/AC-) depending on the breaking current and rated operational voltage. It is assumed that the operating mechanisms are switched randomly, i. e. not synchronized with the phase angle of the supply system The rated operational current I e complies with utilization category AC-4 (breaking six times the rated operational cur rent) and is intended for a contact endurance of at least 4 00,000 operating cycles If a shorter endurance is sufficient, the rated operational current I e /AC-4 can be increased. I e If the contacts are used for mixed operation, i. e. normal switching (breaking the rated operational current according to utilization category AC-) in combination with intermittent inching (breaking several times the rated operational current according to utilization category AC-4), the contact endurance can be calculated approximately from the following equation: A X = C A B Characters in the equation: X Contact endurance for mixed operation in operating cycles A Contact endurance for normal operation (I a = I e ) in operating cycles B Contact endurance for inching (I a = multiple of I e ) in operating cycles C Inching operations as a percentage of total switching operations 0 V V Size S0 0 V V V V V Contactor type RT0 15, RT0 16 ( HP, 5 HP) RT0 17, RT0 18 (7.5 HP, 10 HP) NSB0_ a (A) e (A) 400 V RT0 (5 HP) 5 P (HP) N RT0 4 RT0 5 RT0 6 (7.5 HP) (10 HP) (15 HP) NSB0_0060 RT0 7, RT0 8 (0 HP, 5 HP) a(a) e(a) P N (HP) Diagram legend: P N = Rated power for squirrel-cage motors at 460 V I a = Breaking current I e = Rated operational current /19

20 RT Power Contactors for Switching Motors RT0 contactors, -pole,... 5 HP Type RT0 15, RT0 16 RT0 17, RT0 18 Size S00 S00 Dimensions (W x H x D) 1) mm 45 x 57.5 x 7 / 45 x 70 x 7 With mounted auxiliary switch block mm 45 x 57.5 x 116 / 45 x 70 x 11 With mounted function block W mm 45 x 57.5 x 14 / 45 x 70 x 14 General data Permissible mounting positions The contactors are designed for operation on a vertical mounting surface. H D 60,5,5 NSB0_00478c Upright mounting position Mechanical endurance Basic unit Operating 0 million cycles Basic unit with snap-on auxiliary switch block Operating 10 million cycles Solid-state compatible auxiliary switch block Operat. 5 million cycles Electrical endurance ) Rated insulation voltage U i (pollution degree ) V 690 Rated impulse withstand voltage U imp kv 6 Protective separation between the coil and the main contacts acc. to EN , Appendix N Mirror contacts A mirror contact is an auxiliary NC contact that cannot be closed simultaneously with a NO main contact. RT0 1., RT 1. (removable auxiliary switch block) RT0 1., RT 1. (permanently mounted auxiliary switch block) RH NF.. solid-state compatible auxiliary switch blocks have no mirror contacts. Ambient temperature 1) Dimensions for devices with screw terminals / spring-type terminals. ) For endurance of the main contacts see page /19. V 400 Special version required During operation C During storage C Degree of protection acc. to EN , Appendix C Touch protection acc.to EN 5074 IP0, coil assembly IP40 Finger-safe Shock resistance rectangular pulse Yes, this applies to both the basic unit as well as to between the basic unit and the mounted auxiliary switch block acc. to EN , Appendix F Yes, acc. to EN , Appendix F AC operation g/ms 6.7/5 and 4./10 7./5 and 4.7/10 DC operation g/ms 6.7/5 and 4./10 7./5 and 4.7/10 Shock resistance sine pulse AC operation g/ms 10.5/5 and 6.6/ /5 and 7./10 DC operation g/ms 10.5/5 and 6.6/ /5 and 7./10 Conductor cross-sections ) Short-circuit protection for contactors without overload relays For short-circuit protection for contactors with overload relays see "Protection Equipment --> Overload Relays" For short-circuit protection for fuseless load feeders see "Motor Starters". Main circuit Fuse links, operational class gg : NH NA, DIAZED 5SB, NEOZED 5SE acc. to IEC / EN Type of coordination "1" A Type of coordination "" A Weld-free 4) A Miniature circuit breakers (up to 0 V) with C characteristic A Short-circuit current 1 ka, type of coordination "1" Auxiliary circuit Fuse links, operational class gg : DIAZED 5SB, NEOZED 5SE (weld-free protection for I k 1 ka) Miniature circuit breakers up to 0 V with C characteristic Short-circuit current I k < 400 A A 10 A 6 NSB0_00477a ) For conductor cross-sections see page /. 4) Test conditions according to IEC /0

21 RT Power Contactors for Switching Motors RT0 contactors, -pole,... 5 HP Contactors Type RT0 15, RT0 16 RT0 17, RT0 18 Size S00 S00 Width mm Control Solenoid coil operating range AC operation 50 Hz x U s 60 Hz x U s DC operation Up to 50 C x U s Up to 60 C x U s Power consumption of the solenoid coils (when coil is cold and 1.0 x U s ) AC operation, 50/60 Hz, standard version - Closing VA 7/4. 7/ - P.f. 0.8/ / Closed VA 4./. 5.7/4.4 - P.f. 0.5/ /0.5 AC operation, 50 Hz, USA/Canada - Closing VA P.f. for closing Closed VA P.f. for closed AC operation, 60 Hz, USA/Canada 1) The RT9 16-1GA00 additional load module is recommended for higher residual currents. 1) Industrial furnaces and electric heaters with resistance heating, etc. (increased power consumption on heating up has been taken into account). - Closing VA P.f. for closing Closed VA P.f. for closed DC operation Closing = Closed W 4 4 Permissible residual current of the electronics (with 0 signal) AC operation < ma x (0 V/U s ) 1) <4 ma x (0 V/U s ) 1) Operating times ) Total break time = Opening delay + Arcing time DC operation <10 ma x (4 V/U s ) 1) AC operation - Closing delay ms at x U s - Opening delay ms DC operation - Closing delay ms at x U s - Opening delay ms Arcing time ms ) Operating times for 1.0 x U s AC operation - Closing delay ms Opening delay ms DC operation - Closing delay ms Opening delay ms ) The OFF-delay of the NO contact and the ON-delay of the NC contact are increased if the contactor coils are attenuated against voltage peaks (noise suppression diode 6 to 10 times; diode assemblies to 6 times, varistor + to 5 ms). Contactors Type RT0 15 RT0 16 RT0 17 RT0 18 Size S00 S00 S00 S00 Main circuit AC capacity Utilization category AC-1 Switching resistive loads Rated operational current I e At 40 C up to 690 V A 18 At 60 C up to 690 V A Rated power for AC loads 1) P.f.= 0.95 (at 60 C) 0 V kw V kw V kw V kw 19 Minimum conductor cross-section At 40 C mm for loads with I e At 60 C mm Utilization category AC- Rated operational currents I e Up to 400 V A V A V A V A Rated power for slipring or squirrelcage motors at 50 and 60 Hz At 00 V HP V HP V HP V HP Thermal load capacity 10 s current ) A ) According to IEC For rated values for various start-up conditions see "Protection Equipment" --> "Overload Relays". /1

22 RT Power Contactors for Switching Motors RT0 contactors, -pole,... 5 HP Contactors Type RT0 15 RT0 16 RT0 17 RT0 18 Size S00 S00 S00 S00 Width mm Main circuit AC capacity Power loss per conducting path At I e /AC- W Utilization category AC-4 (for I a = 6 x I e ) 1) Rated operational current I e Up to 400 V A Rated power for squirrel-cage motors with 50 Up to 400 V kw Hz and 60 Hz The following applies to a contact endurance of about operating cycles: - Rated operational currents I e Up to 400 V A V A ) - Rated power for squirrel-cage motors with 50 Hz and 60 Hz Switching frequency Switching frequency z in operating cycles/hour Contactors without overload relays No-load switching h frequency AC Dependence of the switching frequency z' on No-load switching h the operational current I' and operational voltage U': z'=z (I e /I') (400 V/U') 1.5 1/h frequency DC Rated operation AC-1 (AC/DC) h AC- (AC/DC) h AC- (AC/DC) h AC-4 (AC/DC) h Contactors with overload relays (mean value) h The data only apply to RT5 16 and RT5 17 ( NO + NC) up to a rated operational voltage of 400 V. At 0 V kw V kw V kw V kw Contactors Type RT0 15 RT0 16 RT0 17 RT0 18 Size S00 S00 S00 S00 mm Conductor cross-sections Main conductors and auxiliary conductors Screw terminals (1 or conductors can be connected) Solid mm x ( ) 1) ; x ( ) 1) according to IEC 60947; max. x ( ) Finely stranded with end sleeve mm x ( ) 1) ; x ( ) 1) AWG cables, solid or stranded AWG x ( ) 1) ; x ( ) 1) ; x 1 Terminal screw M (for standard screwdriver size and Pozidriv ) Tightening torque Nm ( lb.in) Main conductors, auxiliary conductors and coil terminals Spring-type terminals (1 or conductors can be connected) Operating devices mm.0 x 0.5;.5 x 0.5 Solid mm x ( ) Finely stranded with end sleeve mm x ( ) Finely stranded without end sleeve mm x ( ) AWG cables, solid or stranded AWG 1 x (0... 1) Auxiliary conductors for front and laterally mounted auxiliary switches (1 or conductors can be connected) Operating devices mm.0 x 0.5;.5 x 0.5 Solid mm x ( ) Finely stranded with end sleeve mm x ( ) Finely stranded without end sleeve mm x ( ) AWG cables, solid or stranded AWG x ( ) Main conductors and auxiliary conductors Terminal screw M, Pozidriv d Operating devices d mm Ø Tightening torque Nm mm d = min.. mm d = max. 7.5 Usable ring terminal lugs - DIN 464 without insulation sleeve - DIN 465 without insulation sleeve - DIN 467 with insulation sleeve - JIS C805 Type R without insulation sleeve - JIS C805 Type RAV with insulation sleeve - JIS C805 Type RAP with insulation sleeve For tool for opening the spring-type terminals see Accessories, page /104. Maximum external diameter of the conductor insulation:.6 mm. / I_1740 Ring lug terminal connection An "insulation stop" must be used for conductor cross-sections 1 mm² (see Accessories on page /104). 1) If two different conductor cross-sections are connected to one clamping point, both cross-sections must lie in the range specified.

Switching Devices Contactors and Contactor Assemblies Special Applications

Switching Devices Contactors and Contactor Assemblies Special Applications Switching Devices Contactors and Contactor Assemblies Special Applications Price groups PG 1B, 1H /2 Introduction Contactors for special applications / SIRIUS 3RT1 contactors for resistive loads (AC-1),

More information

AF09-30-22-.. / AF09Z-30-22-.. 2-stack 3-pole Contactors AC / DC Operated - with Screw Terminals

AF09-30-22-.. / AF09Z-30-22-.. 2-stack 3-pole Contactors AC / DC Operated - with Screw Terminals Technical Datasheet 1SBC101403D0201 24/03/11 AF09-30-22-.. / AF09Z-30-22-.. 2-stack 3-pole Contactors AC / DC Operated - with Screw Terminals AF09(Z) contactors are used for controlling power circuits

More information

Mini Motor Contactor J7KNA Main contactor Accessories Approved Standards Standard Guide No (US,C) Ordering Information tage Model Number Legend gear

Mini Motor Contactor J7KNA Main contactor Accessories Approved Standards Standard Guide No (US,C) Ordering Information tage Model Number Legend gear Mini Motor Contactor J7KNA ) Main contactor AC & DC operated Integrated auxiliary contacts Screw fixing and snap fitting (35 mm DIN-rail) Range from 4 to 5.5 (AC 3, 380/415V) 4 -main pole version (4 AC

More information

Type: DILM115(RAC240) Article No.: 239548 Sales text Contactor,55kW/400V,AC operated. Ordering information

Type: DILM115(RAC240) Article No.: 239548 Sales text Contactor,55kW/400V,AC operated. Ordering information Type: DILM115(RAC240) Article No.: 239548 Sales text Contactor,55kW/400V,AC operated Ordering information Connection technique Description Description Rated operational current Screw terminals 3 pole AC

More information

3RT1015-1BB41 CONTACTOR, AC-3 3 KW/400 V,

3RT1015-1BB41 CONTACTOR, AC-3 3 KW/400 V, Automation Technology > Industrial Controls > Switching Devices > Contactors and Contactor Assemblies > Power Contactors for Switching Motors > Contactors SIRIUS 3RT10, 3-pole, 3... 250 kw 3RT1015-1BB41

More information

Electronic overload relay EF19 and EF45

Electronic overload relay EF19 and EF45 Data sheet Electronic overload relay EF19 and EF45 Electronic overload relays offer reliable protection in case of overload and phase-failure. They are the alternative to thermal overload relays. Motor

More information

Relés e Contatores de Estado Sólido SIRIUS

Relés e Contatores de Estado Sólido SIRIUS Relés e Contatores de Estado Sólido SIRIUS Coletânea de dados técnicos ( product data sheet ) Agosto/212 SSR - 3RF21 22,5 mm Ponto Zero SSR - 3RF2 45 mm Ponto Zero SSR - 3RF22 45 mm Ponto Zero Trifásico

More information

Electronic overload relay EF65, EF96 and EF146

Electronic overload relay EF65, EF96 and EF146 Data sheet Electronic overload relay EF65, EF96 and EF146 Electronic overload relays offer reliable protection in case of overload and phase-failure. They are the alternative to thermal overload relays.

More information

NF71E-.. / NFZ71E-.. Contactor Relays AC / DC Operated - with Screw Terminals

NF71E-.. / NFZ71E-.. Contactor Relays AC / DC Operated - with Screw Terminals Technical Datasheet 1SBC101433D0201 28/03/11 NF71E-.. / NFZ71E-.. Contactor Relays AC / DC Operated - with Screw Terminals NF(Z) contactor relays are used for switching auxiliary and control circuits.

More information

Low Voltage Controls & Distribution

Low Voltage Controls & Distribution SIRIUS Datasheet 2009 Low Voltage Controls & Distribution Answers for industry. s Pressing, equipping, transporting. These functions run in many automated production environments. You ll find everything

More information

Switching Devices Contactors and Contactor Assemblies Contactor Relays and Relays

Switching Devices Contactors and Contactor Assemblies Contactor Relays and Relays Siemens AG 2013 Switching Devices Contactors and Contactor Assemblies Contactor Relays and Relays Price groups 41A, 41B, 41H, 4N1 /2 Introduction Contactor relays /4 SIRIUS 3RH2 contactor relays, 4- and

More information

Catalog. Modular DIN rail components Installation contactors

Catalog. Modular DIN rail components Installation contactors Catalog Modular DIN rail components Installation contactors 0 CDC00C00 Installation contactors Benefits and features Overview Ordering details ESB installation contactors ESB0 ESB ESB0 ESB 7 EN installation

More information

LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A - 220 V AC coil

LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A - 220 V AC coil Product data sheet Characteristics LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 -

More information

Technical catalogue. Modular DIN rail components Installation contactors

Technical catalogue. Modular DIN rail components Installation contactors Technical catalogue Modular DIN rail components Installation contactors Installation Contactors Overview... ESB Installation Contactors 0 A / AC-/AC-7a ESB0...4 4 A / AC-/AC-7a ESB4...5 40 A / AC-/AC-7a

More information

3RV Motor Starter Protectors up to 100 A

3RV Motor Starter Protectors up to 100 A General data Overview S0 motor 3RV1 motor are compact, current limiting motor which are optimized for load feeders. The motor are used for switching and protecting three-phase induction motors of up to

More information

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous Safety relay for monitoring E-STOP pushbuttons. Approvals Unit features Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous 1 auxiliary contact (N/C), instantaneous Safe separation of

More information

D-Line Contactors, Overload Relays and Accessories

D-Line Contactors, Overload Relays and Accessories D-Line Contactors, Overload Relays and Accessories Class 850 CONTENTS Description......................................................Page General Information...............................................

More information

IEC style contactors - long electrical and mechanical life Complete range from mini-contactors to 630 Amp i n d u c t i ve AC3 ra t i n g s Wide

IEC style contactors - long electrical and mechanical life Complete range from mini-contactors to 630 Amp i n d u c t i ve AC3 ra t i n g s Wide - long al and mechanical life Complete range from mini-contactors to 630 Amp i n d u c t i ve AC3 ra t i n g s Wide range coils +0% to -30% Finger safe terminals Four-pole versions available NO + NC and

More information

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages Data sheet Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages The CM-ESS.2 is an electronic voltage monitoring relay that provides reliable monitoring of voltages as well as detection of

More information

Power Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1

Power Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1 Power Supply Unit, Primary Switched, Narrow Design MINI POWER provides: Extra narrow design with widths of 22.5 mm, 45 mm, and 67.5 mm (0.886, 1.772, and 2.657 in.) Global use due to a wide-range input

More information

48 SERIES Relay interface modules 10 A

48 SERIES Relay interface modules 10 A 48 Relay interface modules 10 A 1 CO relay interface modules, mm wide Ideal interface for PLC and electronic systems Type 48.P3 1 CO 10 A s Type 48.31 1 CO 10 A s AC coils or DC sensitive coils Supply

More information

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start 0225592. * see variants. Applications.

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start 0225592. * see variants. Applications. Safety Technique SAFEMASTER Emergency Stop Module BG 5924, IP 5924 Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start 0225592 BG 5924 IP 5924 Product Description

More information

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 55 Series - General purpose relays 7-10 A Features 55.12 55.13 55.14 Printed circuit mount, general purpose 2, 3 & 4 Pole relays 55.12-2 Pole 10 A 55.13-3 Pole 10 A 55.14-4 Pole 7 A AC coils & DC coils

More information

Type: EASY719 DC RC Article No.: 274119. Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

Type: EASY719 DC RC Article No.: 274119. Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description Type: EASY719 DC RC Article.: 274119 Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC Description 12 digital inputs (4 inputs available as analog inputs) 6 relay outputs LCD display

More information

Bimetallic Overload Relay Specifications

Bimetallic Overload Relay Specifications Technical Data Bimetallic Overload Relay Specifications Bulletin Number 193K, 193T1 Topic Page Product Overview 2 Standards compliance and Certifications 2 General Specifications 193K 3 Approximate Dimensions

More information

48.12. 2 pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2,000 500 0.37 8/0.65/0.

48.12. 2 pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2,000 500 0.37 8/0.65/0. 48 Series - Relay interface modules 8 A Features 48.12 2 Pole Safety relay interface modules, 15.8 mm wide 48.12-2 Pole 8 A (screw terminal) DC sensitive coils Relay with forcibly guided contacts according

More information

Type: DILM50(230V50HZ,240V60HZ) Article No.: 277830

Type: DILM50(230V50HZ,240V60HZ) Article No.: 277830 Type: DILM50(230V50HZ,240V60HZ) Article No.: 277830 Ordering information Rated operational current AC 3 400 V I e A 50 Max. rating for three phase motors, 50 60 Hz AC 3 230 V Max. rating for three phase

More information

Mini Circuit Breakers, Fuse Blocks, and Electronic Circuit Protection

Mini Circuit Breakers, Fuse Blocks, and Electronic Circuit Protection Technical Data Mini Circuit Breakers, Fuse Blocks, and Electronic Circuit Protection Topic Page 1489-M Miniature Circuit Breakers 2 1492-SP Supplementary Protectors 15 1492-D Circuit Breakers 27 188 Regional

More information

E-STOP relays, safety gate monitors

E-STOP relays, safety gate monitors Unit features Safety features Gertebild ][Bildunterschrift_NOT_Sch.tuer_Licht Safety relay for monitoring E-STOP pushbuttons, safety gates and light beam devices Approvals Gertemerkmale Positive-guided

More information

Type: DILM32 10(24V50HZ) Article No.: 277247

Type: DILM32 10(24V50HZ) Article No.: 277247 Type: DILM32 10(24V50HZ) Article No.: 277247 Ordering information Rated operational current AC 3 400 V I e A 32 Max. rating for three phase motors, 50 60 Hz AC 3 230 V Max. rating for three phase motors,

More information

PSR The compact range Description

PSR The compact range Description Description The PSR range is the most compact of all the ABB softstarter ranges, thereby making it possible to fit many devices into the same enclosure. The system concept with Manual Motor Starters provides

More information

Controls Solid-State Switching Devices

Controls Solid-State Switching Devices Controls Solid-State Switching Devices Introduction Overview 3RF21 3RF20 3RF23 3RF29 SIRIUS SC solid-state switching devices Solid-state relays 22.5 mm solid-state relays, 5 mm solid-state relays Solid-state

More information

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages Data sheet Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages The CM-ESS.2 is an electronic voltage monitoring relay that provides reliable monitoring of voltages as well as detection of

More information

Redundancy Module QUINT-DIODE/40

Redundancy Module QUINT-DIODE/40 Redundancy Module QUT DIODE provides: 00% decoupling of power supplies connected in parallel Can be installed in potentially explosive areas Load currents up to 60 A supported Easy assembly by snapping

More information

RM4TG20 three-phase network control relay RM4-T - range 200..500 V

RM4TG20 three-phase network control relay RM4-T - range 200..500 V Characteristics three-phase network control relay RM4-T - range 200..500 V Complementary [Us] rated supply voltage Output contacts Setting accuracy of time delay Delay at power up Measuring cycle Marking

More information

Emergency stop As an emergency switching off/emergency stop device. Standards According to IEC/EN 60204-1, VDE 0113 Part 1

Emergency stop As an emergency switching off/emergency stop device. Standards According to IEC/EN 60204-1, VDE 0113 Part 1 MainswitchSurfacemounting Partno. P3-63/I4/SVB Articleno. 207343 CatalogNo. SP3-063-I4CRQ IP65 Deliveryprogramme Product range Switch-disconnectors Basic function Main switches Maintenance switches Manual

More information

Micro Contactors. Micro Contactor Relays. Micro Contactors With Solder Pins. Coil voltages. Micro Reversing Contactor. Technical Data.

Micro Contactors. Micro Contactor Relays. Micro Contactors With Solder Pins. Coil voltages. Micro Reversing Contactor. Technical Data. Micro Contactors Micro Contactor Relays 0 Micro Contactors Micro Contactors With Solder Pins Coil voltages Micro Reversing Contactor 3 Technical Data 4 Dimensions 8 9 Micro Contactor Relays 4pole C Operated

More information

Three-phase monitoring relay CM-PFE

Three-phase monitoring relay CM-PFE Data sheet Three-phase monitoring relay CM-PFE The CM-PFE is a three-phase monitoring relay that monitors the phase parameter phase sequence and phase failure in three-phase mains. 2CDC 251 005 S0012 Characteristics

More information

Bulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller

Bulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller Overview/Modes of Operation Bulletin 150 Smart Motor Controller The SMC-3 is a compact, simple to use, solid-state motor controller designed to operate 3-phase motors. It features a built-in overload relay

More information

Bulletin 150 SMC Flex Smart Motor Controller Specifications

Bulletin 150 SMC Flex Smart Motor Controller Specifications Specifications Specifications Standard Features Optional Features Installation Setup Communications Power Wiring Control Wiring Keypad Software Starting and Stopping Modes Protection and Diagnostics Metering

More information

Protection Equipment

Protection Equipment Protection Equipment Price groups 14O, 41B, 41E, 41F, 41G, 41H, 41J, 42F, 42J, 4N1 /2 Introduction Motor starter protectors/ circuit breakers SIRIUS 3RV2 motor starter protectors/ circuit breakers up to

More information

Contact expansion modules

Contact expansion modules Gertebild ][Bildunterschrift Kontakterweiterungen Contact for increasing the number of available contacts Approvals Zulassungen Unit features Gertemerkmale Positive-guided relay outputs: 4 safety contacts

More information

Manual motor starter MS116

Manual motor starter MS116 Data sheet Manual motor starter MS116 Manual motor starters are electromechanical devices for motor and circuit protection. These devices offer local motor disconnect means, manual ON/ OFF control, and

More information

Safety technique. Emergency stop module BO 5988 safemaster

Safety technique. Emergency stop module BO 5988 safemaster Safety technique Emergency stop module BO 5988 safemaster 0221562 Function diagram Pushbutton on Mains or emergencystop () K1 According to EC Directive for machines 98/37/EG According to IEC/E 60204-1

More information

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact Data sheet Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact The CT-AHD.12 is an electronic time relay with OFF-delay. It is from the CT-D range. With their MDRC profile and a width of only

More information

Contact expander modules

Contact expander modules Gertebild ][Bildunterschrift Kontakterweiterungen Contact expansion module for increasing the number of available contacts Approvals Zulassungen Unit features Gertemerkmale Positive-guided relay outputs:

More information

49 Series - Relay interface modules 8-10 - 16 A. Features

49 Series - Relay interface modules 8-10 - 16 A. Features Features 1 & 2 Pole relay interface modules 5 µm Gold plate contacts for low level switching capability 49.31-50x0-1 Pole 10 A (screw terminal) 49.52-50x0-2 Pole 8 A (screw terminal) 49.72-50x0-2 Pole

More information

ABB i-bus KNX Fan Coil Actuator, MDRC FCA/S 1.1M, 2CDG 110 084 R0011

ABB i-bus KNX Fan Coil Actuator, MDRC FCA/S 1.1M, 2CDG 110 084 R0011 , 2CDG 110 084 R0011 2CDC 071 112 F0008 The Fan Coil Actuator is a modular installation device (MDRC) in pro M design. It is intended for installation in the distribution board on 35 mm mounting rails.

More information

Three-phase monitoring relays CM-PSS CM-PSS.31 and CM-PSS.41

Three-phase monitoring relays CM-PSS CM-PSS.31 and CM-PSS.41 Data sheet Three-phase monitoring relays CM-PSS CM-PSS.31 and CM-PSS.41 The three-phase monitoring relays CM-PSS.x1 monitor the phase parameters phase sequence, phase failure as well as over- and undervoltage.

More information

E-STOP relays, safety gate monitors

E-STOP relays, safety gate monitors Unit features Safety features gang engertebild ][Bildunterschrift_NOT_Sch.tuer_Licht Safety relay for monitoring E-STOP pushbuttons, safety gates and light beam devices Approvals Gertemerkmale Positive-guided

More information

Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages

Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages Data sheet Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages The CM-ESS.M is an electronic voltage monitoring relay that provides reliable monitoring of voltages as well as detection of

More information

ABB 1 NEW. Three-phase monitoring relay for grid feeding CM-UFS.1. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories

ABB 1 NEW. Three-phase monitoring relay for grid feeding CM-UFS.1. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories 2CDC 251 014 F0t09 Features Monitoring of three-phase mains for grid feeding Type-tested in accordance with DIN V VDE V 0126-1-1: February 2006 Neutral conductor connection configurable Can also be used

More information

Industrial Communication

Industrial Communication Industrial Communication / AS-Interface System overview /5 - Transmission technology /6 - Configuration examples /7 - Communication overview Slaves Contactors and contactor assemblies for AS-Interface

More information

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2...

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2... Magnetic and Hydraulic-Magnetic Circuit Breaker 840-G2... Description Single, two and three pole magnetic circuit breakers with trip-free mechanism and push/pull on/off manual actuation. A choice of fast

More information

Type: DILM9 10(24VDC) Article No.: 276705

Type: DILM9 10(24VDC) Article No.: 276705 Type: DILM9 10(24VDC) Article No.: 276705 Ordering information Rated operational current AC 3 400 V I e A 9 Max. rating for three phase motors, 50 60 Hz AC 3 230 V Max. rating for three phase motors, 50

More information

PNOZsigma - Base units

PNOZsigma - Base units PNOZsigma - Base units Register Login Sensors Control and Communication Electronic monitoring relays Safety Relays PNOZ X PNOZsigma PNOZelog PNOZmulti PNOZpower Configurable control systems Programmable

More information

R.C.C.B. s two-pole LEXIC

R.C.C.B. s two-pole LEXIC 87045 LIMOGES Cedex Telephone : (+33) 05 55 06 87 87 Fax : (+ 33) 05 55 06 88 88 R.C.C.B. s two-pole LEXIC 089 06/09/10/11/12/15/16/17/18/ 27/28/29/30/35, CONTENTS PAGES 1. Electrical and mechanical characteristics...

More information

Installation Contactors. Technical Catalogue. Type ESB. abb. ABB STOTZ-KONTAKT GmbH 1 2CDC 103002 C0201

Installation Contactors. Technical Catalogue. Type ESB. abb. ABB STOTZ-KONTAKT GmbH 1 2CDC 103002 C0201 Technical Catalogue Installation Contactors Type ESB abb ABB STOTZ-KONTAKT GmbH 1 CDC 10300 C001 ABB STOTZ-KONTAKT GmbH CDC 10300 C001 Low Voltage Products and Systems We ensure safety and comfort for

More information

Thermistor motor protection

Thermistor motor protection Thermistor motor protection CM-E Range Thermistor motor protection Thermistor motor protection relays Benefits and advantages Selection table Operating principle and fields of application for thermistor

More information

BETA Switching. Switching Devices. 5TT5 8 Insta contactors, AC technology. Overview

BETA Switching. Switching Devices. 5TT5 8 Insta contactors, AC technology. Overview BETA Switching Siemens AG 200 5TT5 Insta contactors, AC technology Overview The 5TT5 Insta contactors are equipped with an AC magnetic system and are ideal for use under harsh conditions. The auxiliary

More information

Control Devices Catalogue. Control Devices. Preferred and Standard Products

Control Devices Catalogue. Control Devices. Preferred and Standard Products Control Devices Catalogue Control Devices Preferred and Standard Products KOP.J Timer Electronic 22.5 mm Characteristics Mounting KOP.J 22.5 mm mono or multifunction high immunity to interference surface

More information

5SV Residual Current Protective Devices

5SV Residual Current Protective Devices s Siemens AG 2013 SENTRON 5SV Residual Current Protective Devices New portfolio for reliable personnel, material and fire protection Safe protection against residual currents Residual current protective

More information

Multifunctional three-phase monitoring relays CM-MPS CM-MPS.43

Multifunctional three-phase monitoring relays CM-MPS CM-MPS.43 Data sheet Multifunctional three-phase monitoring relays CM-MPS CM-MPS.43 The three-phase monitoring relay CM-MPS.43 monitors the phase parameters phase sequence, phase failure, over- and undervoltage

More information

PRODUCT GUIDE. SL Medium Voltage IEC Vacuum Contactors

PRODUCT GUIDE. SL Medium Voltage IEC Vacuum Contactors PRODUCT GUIDE SL Medium Voltage IEC Vacuum Contactors Table of Contents 1 Overview Introduction....................................................2 Features........................................................2

More information

BETA Protecting SITOR Semiconductor Fuses

BETA Protecting SITOR Semiconductor Fuses BETA Protecting SITOR Semiconductor Fuses /2 Product overview /3 /17 SITOR, cylindrical fuse design /22 SILIZED, NEOZED and DIAZED design Siemens ET B1 /2008 Product overview Overview Devices Page Field

More information

Pluggable interface relays CR-P Pcb relays

Pluggable interface relays CR-P Pcb relays 2CDC 293 034 F0004 1 2 4 3 Features 9 different supply s: DC versions: 12 V, 24 V, 48 V, 110 V AC versions: 24 V, 48 V, 110 V, 120 V, 230 V Output contacts: 1 c/o (16 A) or 2 c/o (8 A) Cadmium-free contact

More information

ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application.

ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application. 1SR 430 824 F9300 Features Monitoring of three-phase mains for phase sequence and failure Powered by the measuring circuit 2 c/o (SPDT) contacts 1 LED for status indication Approvals R: yellow LED - relay

More information

38 SERIES. Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A. EMR Electromechanical Relays. Common features. SSR Solid State Relays. 6.

38 SERIES. Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A. EMR Electromechanical Relays. Common features. SSR Solid State Relays. 6. 38 Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A 38 Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit 6.2 mm wide EMR - DC, AC or AC/DC

More information

Thermistor motor protection relays CM-MSS.22 and CM-MSS.23

Thermistor motor protection relays CM-MSS.22 and CM-MSS.23 Data sheet Thermistor motor protection relays CM-MSS.22 and CM-MSS.23 The thermistor motor protection relays CM-MSS.22 and CM-MSS.23 monitor the winding temperature of motors and protect them from overheating,

More information

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection) Data sheet Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection) The temperature monitoring relays CM-TCS monitor overtemperature,

More information

How can a charging station for electric vehicles be set up simply and safely?

How can a charging station for electric vehicles be set up simply and safely? SB18 Building > Electromobility > Charging Station Design How can a charging station for electric vehicles be set up simply and safely? Requirement In order to supply electric vehicles with electric power,

More information

Quick Connect. quick - simple - efficient. www.g-mw.de

Quick Connect. quick - simple - efficient. www.g-mw.de Quick Connect quick - simple - efficient www.g-mw.de Phone: +49 9103 7129-0 Fax: +49 9103 7129-207 Innovative connection technology to plug three single-phase current transformers to multifunctional power

More information

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw 4 937 DESIO Current valve for AC 24 V pulse/pause control of electrical loads up to 30 kw SEA45.1 Use The current valve is used for the control of electric heating elements in heating, ventilation and

More information

mecotron Safety relay ESTOP-2 For emergency stop monitoring

mecotron Safety relay ESTOP-2 For emergency stop monitoring E0006 000824 Safety relay E-2 For emergency stop monitoring Description The safety module E-2 for emergency stop monitoring is used for safety breaking one or more circuits and is designed to be incorporated

More information

80 Series - Modular timers 16 A. Features 80.01 80.11

80 Series - Modular timers 16 A. Features 80.01 80.11 80 Series - Modular timers 16 A Features 80.11 Multi-function and mono-function timer range - Multi-function & multi-voltage 80.11 - On-delay, multi-voltage 17.5 mm wide Six time scales from 0.1s to 24h

More information

Plug-in relays Mini ISO relays

Plug-in relays Mini ISO relays Powertrain Systems Chassis Systems Safety Security Body Driver Information Convenience Description Features Limiting continuous current 70 A Dimensional characteristics and the functional allocation of

More information

38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 A

38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 A 38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 A Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit EMR Electromechanical Relays

More information

Series 8146/5-V37 and Series 8150/5-V37

Series 8146/5-V37 and Series 8150/5-V37 www.stahl.de > Clear assignment safe technology easy installation > Intelligent structure only one rotary actuator for frequency-controlled drives ) 20 ms leading auxiliary contact for safe motor disconnection

More information

MasterINTERFACE 39 Series - Relay interface modules

MasterINTERFACE 39 Series - Relay interface modules MasterINTERFACE 39 Series - Relay interface modules Common features Space saving 6.2 mm wide Connections for 16-way jumper link Integral coil indication and protection circuit Secure retention and easy

More information

PHOENIX CONTACT - 2012-12-14. Features

PHOENIX CONTACT - 2012-12-14. Features Electronic monitoring relay for phase sequence, phase failure, and asymmetry monitoring Data sheet 101748_en_03 1 Description PHOEIX COTACT - 2012-12-14 Features Increasingly higher demands are being placed

More information

SUBJECT: How to wire a motor starter Number: AN-MC-004 Date Issued: 2/08/2005 Revision: Original

SUBJECT: How to wire a motor starter Number: AN-MC-004 Date Issued: 2/08/2005 Revision: Original SUBJECT: How to wire a motor starter Number: AN-MC-004 Date Issued: 2/08/2005 Revision: Original A motor starter is a combination of devices to allow an induction motor to start, run and stop according

More information

E-STOP relays, safety gate monitors

E-STOP relays, safety gate monitors Gertebild ][Bildunterschrift Safety relay for monitoring E-STOP pushbuttons and safety gates. Approvals Unit features Gertemerkmale Positive-guided relay outputs: 2 safety contacts (N/O), instantaneous

More information

Safety Relays ESM/ESM-F

Safety Relays ESM/ESM-F Safety Relays ESM/ESM-F More than safety. Safety More than safety. Emil Euchner, the company s founder and inventor of the multiple limit switch, circa 1928. Around the world the Swabian specialists in

More information

Electronic timer CT-VBS.17+18 OFF-delayed without auxiliary voltage, for DC contactors Data sheet

Electronic timer CT-VBS.17+18 OFF-delayed without auxiliary voltage, for DC contactors Data sheet Characteristics Single-function OFF-delay timer for DC contactors, without auxiliary voltage Width.5 mm CDC 5 6 F3 Approvals A culus E CCC CT-VBS a Circuit diagram b Marker label Marks a CE b C-Tick Order

More information

VEO. V4PF480Y/277VSYTK02 Art.Nr.: 2104200. V4PF480Y/277VSYTK02P Art.Nr.: 2104210 TECHNICAL DATA

VEO. V4PF480Y/277VSYTK02 Art.Nr.: 2104200. V4PF480Y/277VSYTK02P Art.Nr.: 2104210 TECHNICAL DATA Monitoring of phase sequence and phase loss Monitoring of asymmetry Temperature monitoring (PTC) Supply voltage 208-480 V AC Supply circuit = measuring circuit 2 change-over contacts Width 45 mm Control

More information

Switching Devices. 8/2 Introduction. 8/5 5TE8 control switches. 8/8 5TE4 pushbuttons. 8/11 5TE5 light indicators. 8/13 5TE On/Off switches

Switching Devices. 8/2 Introduction. 8/5 5TE8 control switches. 8/8 5TE4 pushbuttons. 8/11 5TE5 light indicators. 8/13 5TE On/Off switches Siemens AG 2014 Switching Devices /2 Introduction /5 5TE control switches / 5TE4 pushbuttons /11 5TE5 light indicators /13 5TE On/Off switches /20 5TE DC isolators /22 5ST busbars for modular installation

More information

MasterINTERFACE 39 Series - Relay interface modules

MasterINTERFACE 39 Series - Relay interface modules MasterINTERFACE 39 Series - 39 Common features Space saving 6.2 mm wide Connections for 16-way jumper link Integral coil indication and protection circuit Secure retention and easy ejection by plastic

More information

Example of use: Fuse for a solenoid valve. If the fuse is defective, no information is sent to the electronic component.

Example of use: Fuse for a solenoid valve. If the fuse is defective, no information is sent to the electronic component. Overview Switch and button modules The dimensions of the switch and button modules are adapted to the electronic components in the integral housing. The modules are equipped with the universal clip-on

More information

38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A

38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A 38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A 38 SERIES Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit EMR Electromechanical

More information

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER Application : The RISH CON - Hz transducer is used for frequency measurement. The output signal is proportional to measured frequency and is either load independent DC Current or load independent DC Voltage.

More information

E-STOP relays, safety gate monitors

E-STOP relays, safety gate monitors Unit features Safety features Gertebild ][Bildunterschrift Safety relay for monitoring E-STOP pushbuttons and safety gates. Approvals Gertemerkmale Positive-guided relay outputs: 3 safety contacts (N/O),

More information

1 pole, 16 A Screw terminal connection 35 mm rail (EN 60715) mounting. 2 pole, 8 A Screw terminal connection 35 mm rail (EN 60715) mounting

1 pole, 16 A Screw terminal connection 35 mm rail (EN 60715) mounting. 2 pole, 8 A Screw terminal connection 35 mm rail (EN 60715) mounting Series - Relay interface modules 8-10 - 16 A Features.01.02 1 & 2 pole relay interface modules, screw terminal socket, mm wide. Ideal interface for PL and electronic systems.01-1 Pole 16 A.02-2 Pole 8

More information

CompactLogix Power Supplies Specifications

CompactLogix Power Supplies Specifications Technical Data CompactLogix Power Supplies Specifications 1768 CompactLogix Power Supplies Catalog Numbers 1768-PA3, 1768-PB3 1769 Compact I/O Power Supplies Catalog Numbers 1769-PA2, 1769-PB2, 1769-PA4,

More information

RY2 miniature industrial relays

RY2 miniature industrial relays 6 RY2 Relays of general application For plug-in sockets, 35 mm rail mount acc. to PN-EN 60715 or on panel mounting Flat insert connectors - faston x 0,5 mm Recognitions, certifications, directives: RoHS,

More information

Electro-pneumatic control valves

Electro-pneumatic control valves Electropneumatic control valves 7 Miniature solenoid valves for alternating current Conform to the Low Voltage Directive or mounting on subbase or footprint in accordance with CNOMO recoendation E 066120N

More information

STEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: 2868567. DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase

STEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: 2868567. DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase Extract from the online catalog STEP-PS/1AC/12DC/1.5 Order No.: 2868567 DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase Commercial data EAN 4046356292924 Pack 1 pcs. Customs tariff

More information

Cross-beam scanning system to detect slim objects. 100 mm 3.937 in

Cross-beam scanning system to detect slim objects. 100 mm 3.937 in 891 Object Area Sensor General terms and conditions... F-17 Related Information Glossary of terms... P.1359~ Sensor selection guide...p.831~ General precautions... P.1405 PHOTO PHOTO Conforming to EMC

More information

Power Supplies 3. SDN-P DIN Rail Series

Power Supplies 3. SDN-P DIN Rail Series SDN-P DIN Rail Series The SDN DIN Rail power supplies provide industry leading performance. Sag Immunity, transient suppression and noise tolerant, the SDN series ensures compatibility in demanding applications.

More information

RM17TE 183...528 V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

RM17TE 183...528 V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC Characteristics multifunction control relay RM17-TE - range 183..528 V AC Complementary Reset time Maximum switching voltage Minimum switching current Maximum switching current [Us] rated supply voltage

More information

E-STOP relays, safety gate monitors

E-STOP relays, safety gate monitors Unit features Unit description Gertebild ][Bildunterschrift Safety relay for monitoring E-STOP pushbuttons and safety gates. Approvals Gertemerkmale Positive-guided relay outputs: 3 safety contacts (N/O),

More information