1 I n s u l a t i o n First Issue July 2013 External Wall System NEXT GENERATION INSULATION SOLUTION FOR EXTERNAL MASONRY WALLS Optimum performance rigid vacuum insulation panel aged design value thermal conductivity W/m. K Insulating performance up to five times better than other commonly available insulation materials Ideal for constructions where a lack of construction depth or space is an issue Over 90% (by weight) recyclable Resistant to the passage of water vapour Ideal for new build and refurbishment Non-deleterious material Low Energy Low Carbon Buildings

2 Introduction Design Service The Problem When constructing a wall in new build situations or upgrading the thermal performance of walls in existing buildings there may be a requirement for both low U-values and the thinnest possible wall build-up. For new-build applications, there are increasing regulatory requirements and economic reasons to improve energy efficiency. One of the approaches is to improve the thermal performance of the building fabric whilst keeping the overall construction as thin as possible. There are already high performance insulation products available that will fulfil the majority of these requirements, however in certain areas, for example where the design demands it, a new, thinner, product is needed. In refurbishment there is arguably a greater need to keep wall build-ups as thin as possible. Space is already at a premium and there may be little space for installing new external wall insulation for example because of the available depth of eaves overhangs, encroachment into access routes and the creation of unsightly steps between adjacent insulated and uninsulated walls. Greater thicknesses of external wall insulation could necessitate extending eaves, longer and more costly ings, trims and accessories, and may result in greater reveal depths, reducing natural daylight. The Solution The External Wall System has been developed to help solve these problems. The External Wall System is an optimum performance next generation insulation solution from Insulation. It comprises rigid vacuum insulation panels with a microporous core which is evacuated, encased and sealed in a thin, gas-tight envelope, giving outstanding thermal conductivity, with the thinnest possible solution to insulation problems. The vacuum insulation panels are accompanied by premium performance rigid insulation infill panels which can be cut to fit around penetrations, reveals and where tures and fittings need to be installed. In retrofit applications, the External Wall System provides solutions for areas that previously could have remained un-insulated because of insufficient space available. In new constructions the External Wall System can significantly enhance U-values in areas that would otherwise be accepted as denigrating the overall thermal performance. With an aged design value thermal conductivity (λ) of W/m.K, the element of the External Wall System provides an insulating performance that is up to five times better than other commonly available insulation materials. 2 The External Wall System comprises 3 elements: panels, flex infill panels and ing panels. It comes with a supporting design service which ensures the ratio of the element of the External Wall System to flex and for each project is maximised. The panel layout will be designed quickly and effectively, ready for client approval. Each layout will illustrate the size, number and location of the panels. It will also illustrate the size, number and location of any flex and panels required. Examples of a typical design layout can be seen in Figures 1 & 2. For more details please contact the Insulation Technical Service Department (see rear cover). Figure 1: A typical terraced property ready for a render carrier board / brick slip finish Figure 2: A typical property ready for a ventilated cladding finish flex flex

3 Typical Constructions and U values Assumptions The U values in the tables that follow have been calculated, under a management system certified to the BBA Scheme for Assessing the Competency of Persons to Undertake U value and Condensation Risk Calculations, using the method detailed in BS / I.S. EN ISO 6946: 2007 (Building components and building elements. Thermal resistance and thermal transmittance. Calculation method), and using the conventions set out in BR443 (Conventions for U value calculations). They are valid for the constructions shown in the details immediately above each table. Refurbishment 100 mm Brick / 50 mm Cavity / 100 mm Brick Wall Render system incorporating EML or glass fibre mesh Render carrier board (magnesium silicate) 13 mm dense plaster For the refurbishment examples, the internal wall finish is taken as 13 mm dense plaster unless stated otherwise. For the new build examples, the internal wall finish is taken to be a 3 mm skim coated 12.5 mm plasterboard on dabs, unless stated otherwise. In all examples, where the external wall finish is rendered, this is taken to be a 10 mm polymer render. Brick slips on carrier track Mechanical ings NB When calculating U values to BS / I.S. EN ISO 6946: 2007, the type of mechanical ing used may change the thickness of insulation required. These calculations assume the use of carbon steel fasteners of cross sectional area of 7.44 mm 2 at a density of 2.88 per m 2 (for the 'render carrier board' or 'Brick Slips' options) or 4.4 per m 2 (for the 'Ventilated Cladding' options) for ing the external finishes to the appropriate horizontal or vertical panels. The calculations also assume thermally broken fasteners with a thermal conductivity 1.00 W/m. K or less, the effect of which is insignificant, for the ing of and flex. NB For the purposes of these calculations the standard of workmanship has been assumed good, and therefore the correction factor for air gaps has been ignored. NB The figures below are for guidance only. A detailed U value calculation and a condensation risk analysis should be completed for each project. NB If your construction is different from those specified, and / or to gain a comprehensive U value calculation along with a condensation risk analysis of your project, please consult the Insulation Technical Service Department for assistance (see rear cover). N.B. For the purposes of these calculations, the bridging effect of and flex has been taken to be 30%. * Refer to Sitework Figure 3 U values for Various Thicknesses of External Wall System with a 10 mm Polymer Render on Render Carrier Board or Brick Slips on a Carrier Track Insulant Thickness U values (W/m 2. K) (mm)

4 Typical Constructions and U values 100 mm Brick / 50 mm Cavity / 100 mm Brick Wall Solid Brick Wall 13 mm dense plaster 13 mm dense plaster Render system incorporating EML or glass fibre mesh Timber cladding on battens Render carrier board (magnesium silicate) Mechanical ings Mechanical ings Slate / tile on tiling battens and vertical battens Brick slips on carrier track * Refer to Sitework * Refer to Sitework Figure 4 U values for Various Thicknesses of External Wall System with Ventilated Cladding e.g. Timber or Tile Hanging Insulant Thickness U values (W/m 2. K) (mm) Figure 5 U values (W/m 2. K) for Various Thicknesses of the System with a 10 mm Polymer Render on Render Carrier Board or Brick Slips on a Carrier Track Insulant Brickwork Thickness Thickness (mm) (mm)

5 New Build Solid Brick Wall 215 mm Solid Blockwork Wall 13 mm dense plaster 3 mm skim coated 12.5 mm plasterboard on plaster dabs Timber cladding on battens Render system incorporating EML or glass fibre mesh Render carrier board (magnesium silicate) Mechanical ings Mechanical ings Slate / tile on tiling battens and vertical battens Brick slips on carrier track * Refer to Sitework * Refer to Sitework Figure 6 U values (W/m 2. K) for Various Thicknesses of External Wall System with Ventilated Cladding e.g. Timber or Tile Hanging Insulant Brickwork Thickness Thickness (mm) (mm) Figure 7 U values (W/m 2. K) for Various Thicknesses of System with a 10 mm Polymer Render on Render Carrier Board or Brick Slips on a Carrier Track Blockwork Density and λ value (W/m. K) Insulant Thickness Thin Joint (mm) Dense Medium Lightweight Aerated Aerated (1.13) (0.51) (0.15)* (0.11)* (0.11)** * A 6.6% thermal bridging factor has been assumed for the effect of mortar joints. ** A 1.4% thermal bridging factor has been assumed for the effect of mortar joints. 5

6 Typical Constructions and U values 215 mm Solid Blockwork Wall Timber cladding on battens Slate / tile on tiling battens and vertical battens * Refer to Sitework Figure 8 Insulant Thickness (mm) 3 mm skim coated 12.5 mm plasterboard on plaster dabs Mechanical ings U values (W/m 2. K) for Various Thicknesses of External Wall System with Ventilated Cladding e.g. Timber or Tile Hanging Blockwork Density and λ value (W/m. K) Thin Joint Dense Medium Lightweight Aerated Aerated (1.13) (0.51) (0.15)* (0.11)* (0.11)** * A 6.6% thermal bridging factor has been assumed for the effect of mortar joints. ** A 1.4% thermal bridging factor has been assumed for the effect of mortar joints. Linear Thermal Bridging at Openings Linear thermal bridging describes the heat loss at junctions between elements, where the geometry of the junction means that a building s primary insulation layer is not continuous or is reduced. This heat loss is represented by the junction s psi (ψ) value. The ψ values of all the linear thermal bridges in a building are used in whole building carbon dioxide emissions calculation software. At a window or door openings, in a wall insulated with the External Wall System, the linear thermal bridge is the reveal. This linear thermal bridge can be avoided, by positioning the window frame so that its outer face is flush with the outer surface of the masonry wall, and overlapping the window frame with the external wall insulation. If this is not possible, this linear thermal bridge can be reduced by insulating the reveal. The key factor is the thermal resistance (R value) of this insulation layer. Accredited Construction Details (England & Wales / Scotland / Northern Ireland) and Acceptable Construction Details (Republic of Ireland), collectively referred to here as ACDs, feature details for walls with external wall insulation, with reveals insulated with a material of minimum thermal resistance (R value) of 0.60 m 2.K/W. These constructions have the following ψ values: 0.50 W/m.K for a steel lintel with a perforated steel base, 0.30 W/m.K for other lintels (including steel lintels), 0.04 W/m.K for a sill and 0.05 W/m.K for a jamb. Adhering to these constructions, entitles a designer to use a default y value in whole building carbon dioxide emissions calculation software. ACDs are specifically targeted at new build constructions but, where applicable, they are also considered best practice for refurbishment. Reveals should be designed to accommodate the 20 mm of flex required to achieve an R value of 0.6 m 2.K/W, and the depth of the cladding system (see Figure 9). Masonry Reduced insulation thickness in reveal Window flex 6 Figure 9

7 Design Considerations Responsible Sourcing Responsible Sourcing The External Wall System is manufactured under a management system certified to EN ISO 14001: Specification Clause The element of the External Wall System should be described in specifications as:- The external wall insulation shall be the External Wall System mm thick: comprising a rigid vacuum insulation panel with a microporous core which is evacuated, encased and sealed in a thin, gastight envelope. The product shall be manufactured under a management system certified to ISO 9001: 2008, ISO 14001: 2008 and OHSAS 18001: 2007, and installed in accordance with the instructions issued by Insulation Limited. Sustainability & Responsibility Insulation has a long-term commitment to sustainability and responsibility: as a manufacturer and supplier of insulation products; as an employer; as a substantial landholder; and as a key member of its neighbouring communities. NBS Specifications Details also available in NBS Plus. NBS users should refer to clause(s): M21 210, M21 220, M (Standard and Intermediate) M21 20 (Minor Works) Water Vapour Control / Condensation Consideration should be given to the risk of condensation, when designing thermal elements. A condensation risk analysis should be carried out following the procedures set out in BS 5250: 2002 (Code of practice for the control of condensation in buildings). The Insulation Technical Service Department (see rear cover) can provide this service. Fire Stops Current Building Regulations / Standards should be considered with regard to the requirements for, and provision of, fire stops. A report covering the sustainability and responsibility of Insulation Ltd s British operations is available at 7

8 Sitework Insulated Render Systems Because insulated render systems are proprietary and utilise different mechanisms for attaching insulation to the wall structure, sitework guidance should be sought from the render system manufacturer. In the absence of any other guidance, the instructions laid out below may be followed. The external masonry wall should be clean, flat, and free from protrusions. Where an uneven surface remains, it is recommended that a levelling compound be applied. External wall insulation should start 150 / 200 / 600* mm below the top surface of the ground floor insulation / perimeter insulation upstand (whichever is higher) for a concrete floor, or 200 mm below the top surface of the ground floor insulation / perimeter insulation upstand (whichever is higher) for a suspended timber floor. * 150 mm applies to the UK. 200 mm applies to the Republic of Ireland if a row of insulating blockwork (thermal conductivity < 0.20 W/m. K) is used, otherwise 600 mm applies., minimum 100 mm wide, should be installed horizontally at maximum 600 mm vertical centres, in order to provide a ing point for the subsequent attachment of the render carrier board which will accept the render finish or the carrier track which will accept the brick slip system. should be of the same thickness as the specified element of the External Wall System. should be mechanically ed back to the substrate using The element of the External Wall System should be installed between with board edges lightly butted. Remaining areas of wall around openings and other details which can not be insulated with the element of the External Wall System should be in-filled with an equal thickness of flex. The element of the External Wall System should be restrained to the substrate using a suitable proprietary adhesive. For further advice on the specification of the proprietary adhesive and application guidance please contact the Insulation Technical Services Department. flex should be mechanically ed back to the substrate using appropriate mechanical fasteners, preferably thermally. Care should be taken to install the specified thickness of insulation around reveals (see Figure 9). Once the, and flex have been installed, a render carrier board is installed in a continuous layer over the assembly and ed back to the substrate through the horizontal in order to accept the render finish. Alternatively a carrier track can be installed to accept a brick slip finish. When selecting the type of ing and ing frequency, consideration must be given to the weight of the cladding, the design of the wall and wind loading. For details on suitable ings please consult the appropriate ing and cladding manufacturer. Care must be taken to ensure fasteners do not penetrate the element of the External Wall System. Wherever possible, care should be taken to avoid cold bridging when attaching services and ancillaries to the exterior of the building (see Figure 10). Depending on the render finish being applied, advice must be sought from the render manufacturer on the EML / glass fibre mesh and bedding mortar to be applied. In refurbishment projects, sill extenders and flashings should be used around openings, with care taken to avoid cold bridging (see Figure 11). Proprietary bracket ings dependant on substrate Mechanical ing Extension back plate ed to substrate prior to insulation being applied * Refer to Sitework Figure 10 Drainpipe Extension Detail (Applicable to a Variety of External Building Ancillaries) PVC corner bead Insulated reveal Window Oversill with boxed end, trimmed on site and ed to reveal Mastic / silicon seal between oversill, window frame and render Original sill cut back to allow full depth of insulation to be carried up to the reveal 20 mm (min.) of flex Oversill with boxed end Mechanical ing 10 mm polymer render on carrier board or brick slips on carrier track * Refer to Sitework Approx. 25 mm Figure 11 Oversill Extension Detail (Refurbishment) flex 10 mm polymer render on carrier board or brick slips on carrier track All penetrations to render finish should be sealed e.g. with silicone sealant 8

9 Ventilated Cladding Systems The external masonry wall should be clean, flat, and free from protrusions. Where an uneven surface remains, it is recommended that a levelling compound be applied. External wall insulation should start 150 / 200 / 600* mm below the top surface of the ground floor insulation / perimeter insulation upstand (whichever is higher) for a concrete floor, or 200 mm below the top surface of the ground floor insulation / perimeter insulation upstand (whichever is higher) for a suspended timber floor. * 150 mm applies to the UK. 200 mm applies to the Republic of Ireland if a row of insulating blockwork (thermal conductivity < 0.20 W/m. K) is used, otherwise 600 mm applies., minimum 100 mm wide, should be installed vertically at maximum 600 mm horizontal centres, in order to provide a ing point for the subsequent attachment of the timber battens which will accept the ventilated cladding system. Strips should be of the same thickness as the specified element of the External Wall System. should be mechanically ed back to the substrate using appropriate mechanical fasteners, preferably thermally broken. The element of the External Wall System should be installed between the with board edges lightly butted. Remaining areas of wall around openings and other details which can not be insulated with the element of the External Wall System should be in-filled with an equal thickness of flex. The element of the External Wall System should be restrained to the substrate using a suitable proprietary adhesive. For further advice on the specification of the proprietary adhesive and application guidance please consult the Insulation Technical Services Department for assistance. flex should be mechanically ed back to the substrate, using appropriate mechanical fasteners, preferably thermally broken. Care should be taken to install the specified thickness of insulation around reveals (see Figure 9). Once the, and flex have been installed, a breathable membrane, e.g. nilvent, is installed over the System and temporarily stapled or pinned in place to the vertical. Minimum 38 mm x 38 mm vertical treated softwood timber battens are ed through the breathable membrane and the installed vertical to the substrate behind. Care must be taken to ensure fasteners do not penetrate the element of the External Wall System. When selecting the type of ing and ing frequency for the vertical battens, consideration must be given to the weight of cladding to be ed to them, the design of the wall, and wind loading. For details on suitable ings, please consult the appropriate ing and cladding manufacturer. If the cladding system is to be tile / slate hanging, horizontal tiling battens can then be ed to the vertical battens. Horizontal tiling battens and the tile / slate cladding that is to be ed to them should be installed in accordance with the tile / slate cladding manufacturers recommendations. Alternatively, timber cladding can be ed directly to the vertical battens. If the cladding system is to be finished with render, the render carrier board (e.g. magnesium silicate building board, expanded metal lath) can be ed directly to the vertical battens. The dry cladding system should be secured in accordance with the manufacturer s recommendations. Wherever possible, care should be taken to avoid cold bridging when attaching services and ancillaries to the exterior of the building. In refurbishment projects, sill extenders and flashings should be used around openings, with care taken to avoid cold bridging. 9

10 Sitework General The element of the External Wall System should not be used in association with solvent based adhesive systems. The element of the External Wall System should not be exposed to naked flames or excessive heat. Cutting The element of the External Wall System should not be cut or penetrated. The substrate must be clean, dry and level, and free of sharp objects or edges. Cutting of the and flex should be carried out either by using a fine toothed saw, or by scoring with a sharp knife, snapping the board over a straight edge and then cutting the facing on the other side. Ensure accurate trimming of the and flex to achieve close butting joints and continuity of insulation. Packaging and Storage The packaging of the External Wall System should not be considered adequate for outdoor protection. The External Wall System should be stored inside a building and raised off the floor. Health and Safety Insulation products are chemically inert and safe to use. A Safety Information Data Sheet for this product is available from the Insulation website or Warning do not stand on or otherwise support your weight on this product unless it is fully supported by a load bearing surface. Please note that the reflective surface on this product is designed to enhance its thermal performance. As such, it will reflect light as well as heat, including ultraviolet light. Therefore, if this panel is being installed during very bright or sunny weather, it is advisable to wear UV protective sunglasses or goggles, and if the skin is exposed for a significant period of time, to protect the bare skin with a UV block sun cream. Availability Please contact Insulation for availability of the External Wall System. 10

11 Product Details Composition The element of the External Wall System comprises a rigid vacuum insulation panel with a microporous core which is evacuated, encased and sealed in a thin, gas tight envelope. and flex comprises a premium performance rigid insulation faced on both sides with a composite foil facing. Standards and Approvals The External Wall System is manufactured to the highest standards under a management system certified to ISO 9001: 2008 (Quality Management Systems. Requirements), ISO 14001: 2004 (Environmental Management Systems. Requirements) and OHSAS 18001: 2007 (Health and Safety Management Systems. Requirements). Standard Dimensions The External Wall System panels are available in the following standard size(s): Nominal Dimension Availability Length (mm) Width (mm) Insulant Thickness (mm) Other sizes may be available dependent on order quantity. Please contact Insulation for more details. Compressive Strength The compressive strength of the element of the External Wall System typically exceeds 160 kpa at 10% compression when tested to BS / I.S. EN ISO 826: 1996 (Thermal insulating products for building application. Determination of compression behaviour). Durability If installed correctly and protected from damage and penetration, the External Wall System can provide reliable long term thermal performance over the lifetime of the building. Resistance to Solvents, Fungi & Rodents The External Wall System should not be used in association with solvent-based adhesive systems. Damaged boards or boards that have been in contact with solvents or acids should not be used. The insulation core and facings used in the manufacture of the External Wall System resist attack by mould and microbial growth, and do not provide any food value to vermin. Fire Performance Details on the fire performance of Insulation products may be obtained from the Insulation Technical Service Department (see rear cover). Thermal Properties The λ values and R values detailed below are quoted in accordance with BS /I.S. EN 12667: 2001 (Thermal performance of building materials and products. Determination of thermal resistance by means of guarded hot plate and heat flow meter methods. Products of high and medium thermal resistance), with allowance for ageing and edge effect of the encapsulating film to form the design value. Thermal Conductivity The element of the External Wall System achieves a thermal conductivity (λ value) of W/m. K (aged design value allowing for edge effect). Thermal Resistance Thermal resistance (R value) of the element of the Flooring System varies with thickness and is calculated by dividing the thickness of the panel (expressed in metres) by the thermal conductivity. Insulant Thickness (mm) Thermal Resistance (m 2. K/W) ,

12 Contact Details Customer Service For quotations, order placement and details of despatches please contact the Insulation Customer Service Department on the numbers below: UK Tel: +44 (0) Fax: +44 (0) Ireland Tel: +353 (0) Fax: +353 (0) Literature & Samples Insulation produces a comprehensive range of technical literature for specifiers, contractors, stockists and end users. The literature contains clear user friendly advice on typical design; design considerations; thermal properties; sitework and product data. Available as a complete Design Manual or as individual product brochures, Insulation technical literature is an essential specification tool. For copies please contact the Insulation Marketing Department, or visit the Insulation website, using the details below: UK Tel: +44 (0) Fax: +44 (0) literature@kingspaninsulation.co.uk Ireland Tel: +353 (0) Fax: +353 (0) info@kingspaninsulation.ie Tapered Roofing For technical guidance, quotations, order placement and details of despatches please contact the Insulation Tapered Roofing Department on the numbers below: UK Tel: +44 (0) Fax: +44 (0) tapered@kingspaninsulation.co.uk Ireland Tel: +353 (0) Fax: +353 (0) tapered@kingspaninsulation.ie Technical Advice / Design Insulation supports all of its products with a comprehensive Technical Advisory Service for specifiers, stockists and contractors. This includes a computer aided service designed to give fast, accurate technical advice. Simply phone the Insulation Technical Service Department with your project specification. Calculations can be carried out to provide U values, condensation / dew point risk, required insulation thicknesses etc Thereafter any number of permutations can be provided to help you achieve your desired targets. The Insulation Technical Service Department can also give general application advice and advice on design detailing and ing etc... Site surveys are also undertaken as appropriate. The Insulation British Technical Service Department operates under a management system certified to the BBA Scheme for Assessing the Competency of CERTIFICATE CS/ Persons to Undertake U value and U Value Competency Scheme Condensation Risk Calculations. Please contact the Insulation Technical Service Department on the numbers below: UK Tel: +44 (0) Fax: +44 (0) technical@kingspaninsulation.co.uk Ireland Tel: +353 (0) Fax: +353 (0) technical@kingspaninsulation.ie General Enquiries For all other enquiries contact Insulation on the numbers below: UK Tel: +44 (0) Fax: +44 (0) info@kingspaninsulation.co.uk Ireland Tel: +353 (0) Fax: +353 (0) info@kingspaninsulation.ie Insulation Ltd. reserves the right to amend product specifications without prior notice. Product thicknesses shown in this document should not be taken as being available ex stock and reference should be made to the current Insulation price list or advice sought from Insulation s Customer Service Department (see above left). The information, technical details and ing instructions etc. included in this literature are given in good faith and apply to uses described. Recommendations for use should be verified for suitability and compliance with actual requirements, specifications and any applicable laws and regulations. For other applications or conditions of use, Insulation offers a Technical Advisory Service (see above), the advice of which should be sought for uses of Insulation products that are not specifically described herein Please check that your copy of this literature is current by contacting the Insulation Marketing Department (see left). Insulation Ltd is a member of: The Insulated Render and Cladding Association (INCA) The National Insulation Association (NIA) Insulation Ltd Pembridge, Leominster, Herefordshire HR6 9LA, UK Castleblayney, County Monaghan, Ireland nilvent, the zo Device and the Lion Device are Registered Trademarks of the Group plc in the UK, Ireland and other countries. All rights reserved. Optim-R is a Trademark of the Group plc. Registered in England & Wales, No Registered Office: Pembridge, Leominster, Herefordshire HR6 9LA UK. VAT GB Registered in Ireland, No Registered Office: Bree Industrial Estate, Castleblayney, Co. Monaghan, Ireland. VAT IE J.

The Kingspan Insulation Price List 1 st January 2013

The Kingspan Insulation Price List 1 st January 2013 Insulation The Kingspan Insulation Price List 1 st January 2013 FOR BUILDING FABRIC INSULATION, CAVITY CLOSERS AND MEMBRANES Visit our website: www.kingspaninsulation.co.uk Low Energy - Low Carbon Buildings

More information

Timber Frame Walls Rethinking Construction

Timber Frame Walls Rethinking Construction Insulation Fifth Issue November 2007 Timber Frame Walls Rethinking Construction INSULATION BEST PRACTICE FOR THE 21ST CENTURY Summary 9 mm OSB sheathing 3 mm skim coated 15 mm plasterboard Rock or glass

More information

Building Regulations for the Conservation of Fuel and Power

Building Regulations for the Conservation of Fuel and Power Insulation CI/SfB Rn7 M2 First Issue April 2014 Building Regulations for the Conservation of Fuel and Power ENGLAND EXISTING DWELLINGS 2013 EDITION Low Energy Low Carbon Buildings Contents Page Introduction

More information

K15 Rainscreen Board. Insulation INSULATION FOR USE BEHIND RAINSCREEN FAÇADES. Low Energy Low Carbon Buildings. CI/SfB

K15 Rainscreen Board. Insulation INSULATION FOR USE BEHIND RAINSCREEN FAÇADES. Low Energy Low Carbon Buildings. CI/SfB Insulation CI/SfB (21.9) Rn7 M2 Tenth Issue July 2016 K15 Rainscreen Board INSULATION FOR USE BEHIND RAINSCREEN FAÇADES l Premium performance rigid thermoset phenolic insulation thermal conductivity as

More information

The Real Value of Space

The Real Value of Space Insulation First Issue May 2015 The Real Value of Space IN COMMERCIAL REAL ESTATE THE IMPACT OF DIFFERING INSULATION SPECIFICATIONS ON THE ROI ASSOCIATED WITH INTERNAL FLOOR AREA Find additional space

More information

TR31. I n s u l a t i o n. Low Energy Low Carbon Buildings

TR31. I n s u l a t i o n. Low Energy Low Carbon Buildings I n s u l a t i o n CI/Sfb (27.9) Rn7 M2 Sixth Issue March 2011 TR31 STRUCTURAL INSULATION / FSC CERTIFIED PLYWOOD COMPOSITE FOR FLAT ROOFS WATERPROOFED WITH PARTIALLY BONDED BUILT UP FELT High performance

More information

Low Energy Low Carbon Buildings

Low Energy Low Carbon Buildings I n s u l a t i o n CI/Sfb (27.9) Rn7 M2 Seventh Issue March 2011 TR26 LPC/FM INSULATION FOR FLAT ROOFS WATERPROOFED WITH MECHANICALLY FIXED SINGLE PLY WATERPROOFING High performance rigid thermoset insulation

More information

I n s u l a t i o n. Eighth Issue July 2014 BREEAM 2011 PRODUCTS ACHIEVE? KOOLDUCT & THERMA TM. Low Energy Low Carbon Buildings

I n s u l a t i o n. Eighth Issue July 2014 BREEAM 2011 PRODUCTS ACHIEVE? KOOLDUCT & THERMA TM. Low Energy Low Carbon Buildings I n s u l a t i o n Eighth Issue July 2014 BREEAM 2011 WHAT CREDITS CAN KINGSPAN KOOLTHERM, KOOLDUCT & THERMA TM PRODUCTS ACHIEVE? Low Energy Low Carbon Buildings BREEAM 2011 Introduction BREEAM (the Building

More information

Basements. I n s u l a t i o n. Low Energy Low Carbon Buildings

Basements. I n s u l a t i o n. Low Energy Low Carbon Buildings I n s u l a t i o n CI/Sfb (13.9) Rn7 M2 Third Issue March 2011 INSULATION FOR BASEMENTS Basements High performance rigid extruded polystyrene insulation thermal conductivities as low as 0.029 W/m.K High

More information

TR21. I n s u l a t i o n. Low Energy Low Carbon Buildings

TR21. I n s u l a t i o n. Low Energy Low Carbon Buildings I n s u l a t i o n CI/Sfb (27.9) Rn7 M2 Fourth Issue March 2011 TR21 INSULATION FOR FLAT ROOFS WATERPROOFED WITH PARTIALLY BONDED BUILT UP FELT AND MASTIC ASPHALT High performance rigid thermoset insulation

More information

Section 5.0. Basements. Wall insulated externally. Wall insulated internally. Ba02. Product: Polyfoam ECO Floorboard Ba01.

Section 5.0. Basements. Wall insulated externally. Wall insulated internally. Ba02. Product: Polyfoam ECO Floorboard Ba01. Section 5.0 Basements Wall insulated externally Product: Polyfoam ECO Ba01 Wall insulated internally Product: Polyfoam ECO Ba02 Basements Basements Basement design Waterproofing BS 8102: 2009 Code of practice

More information

Steel-framed Walls. Insulation

Steel-framed Walls. Insulation Insulation A4/8 SF AW1192 Issue 4 Nov 2012 Steel-framed Walls Insulation guide Helps achieve a 6-star house energy rating Rigid and flexible Kingspan AIR-CELL solutions available Vapour barrier or vapourpermeable

More information

Multi-layer Insulation Blanket for Roofs

Multi-layer Insulation Blanket for Roofs Multilayer Insulation Blanket for Roofs Thermal Insulation in a 40mm thin, flexible, multilayer membrane Meets requirements of L1A, L1B 2010 In accordance with BR443 NHBC Acceptance Pitched & Flat roof

More information

Rockwool Flexi Insulation Application Guide

Rockwool Flexi Insulation Application Guide Pitched roof Rafters InterMediate floors INTERNAL partitions external Framed walls separating floors Separating Walls Rockwool Flexi Insulation Application Guide Ground floor The perfect fit for any framed

More information

Contents. APA Construction Details. Full fill cavity walls 2-13. Partial fill cavity walls 14-25. Solid externally insulated walls 26-37

Contents. APA Construction Details. Full fill cavity walls 2-13. Partial fill cavity walls 14-25. Solid externally insulated walls 26-37 Contents Pages Full fill cavity walls 2-13 Partial fill cavity walls 14-25 Solid externally insulated walls 26-37 Appendix (BRE confirmation of Ψ and y-values) 38-40 Page 1 of 40 APA Construction Details

More information

Module 3.7. Thermal bridging

Module 3.7. Thermal bridging Module 3.7 Thermal bridging Learning Outcomes On successful completion of this module learners will be able to - Describe construction details which influence thermal bridging. 2 Introduction to thermal

More information

CERTIFICATE NAME OF PRODUCT MANUFACTURER PRODUCT DESCRIPTION CERTIFICATION PROCEDURE. No VTT C-6044-10 Date of issue 11.10.2010, Updated July 1, 2011

CERTIFICATE NAME OF PRODUCT MANUFACTURER PRODUCT DESCRIPTION CERTIFICATION PROCEDURE. No VTT C-6044-10 Date of issue 11.10.2010, Updated July 1, 2011 CERTIFICATE NAME OF PRODUCT No VTT C-6044-10 Date of issue 11.10.2010, Updated July 1, 2011 H-CONTROL REFLEX+ reflective insulating vapour control layer for roof and wall applications MANUFACTURER ACTIS

More information

Rockwool Cladding Roll

Rockwool Cladding Roll Rockwool Cladding Roll High performance industrial insulation has been specifically developed for use in lightweight cladding applications to commercial or industrial framed buildings. Cladding Roll U/F

More information

CI/SfB 2- Rj7 December 2010

CI/SfB 2- Rj7 December 2010 Engineered Timber Systems CI/SfB 2- Rj7 December 2010 STANDARD DETAILS Contents Wall Details W1 Typical wall section. W2 a Sectional elevation through soleplate fixing detail. Ground bearing slab. W2 b

More information

TP10. Insulation RAFTER LEVEL INSULATION FOR TILED OR SLATED PITCHED WARM ROOF SPACES BBA BRITISH

TP10. Insulation RAFTER LEVEL INSULATION FOR TILED OR SLATED PITCHED WARM ROOF SPACES BBA BRITISH Insulation CI/Sfb (27.9) Rn7 M2 Fifth Issue May 2007 TP10 RAFTER LEVEL INSULATION FOR TILED OR SLATED PITCHED WARM ROOF SPACES High performance rigid urethane insulation thermal conductivity 0.023 W/m.K

More information

Section 3.1.2. Timber Frame Walls. Single layer between studs. Single layer between studs with service void. Between studs with insulated lining

Section 3.1.2. Timber Frame Walls. Single layer between studs. Single layer between studs with service void. Between studs with insulated lining Section Timber Frame Walls Single layer between studs Product: Earthwool FrameTherm Rolls and Slabs Tf01 Single layer between studs with service void Product: Earthwool FrameTherm Rolls and Slabs Tf02

More information

KINGSPAN INSULATION KINGSPAN KOOLTHERM K12 FRAMING BOARD INSULATION

KINGSPAN INSULATION KINGSPAN KOOLTHERM K12 FRAMING BOARD INSULATION Kingspan Insulation Limited Pembridge Leominster Herefordshire HR6 9LA Tel: 01544 388601 Fax: 01544 388888 e-mail: general.enquiries@kil.kingspan.co.uk APPROVAL INSPECTION TESTING CERTIFICATION TECHNICAL

More information

Built-up roofing solutions with rigid insulation boards on concrete decks for new-build and refurbishment E-a5

Built-up roofing solutions with rigid insulation boards on concrete decks for new-build and refurbishment E-a5 Cl Sfb (27-9) Rn7 M2 December 2004 Built-up roofing solutions with rigid insulation boards on concrete decks for new-build and refurbishment E-a5 Fesco, Fesco S, Retrofit, Retrofit S, Fesco Fillet, PF,

More information

I n s u l a t i o n. Low Energy Low Carbon Buildings

I n s u l a t i o n. Low Energy Low Carbon Buildings I n s u l a t i o n CI/Sfb (47) Ln6 Sixth Issue March 2011 BREATHABLE MEMBRANE FOR UNVENTILATED PITCHED ROOFS AND TIMBER FRAME WALLS Waterproof can be used as a temporary roof covering Non tenting Airtight

More information

Introduction & Principles Issued in support of Junction Details, Parts 1 to 5

Introduction & Principles Issued in support of Junction Details, Parts 1 to 5 Accredited Construction Details (Scotland) 2010 For the limitation of thermal bridging and air infiltration in low and medium rise domestic buildings Introduction & Principles Issued in support of Junction

More information

Low Energy Low Carbon Buildings

Low Energy Low Carbon Buildings I n s u l a t i o n CI/Sfb (27.9) Rn7 M2 Eighth Issue March 2011 TR27 LPC/FM INSULATION FOR FLAT ROOFS WATERPROOFED WITH FULLY ADHERED SINGLE PLY, PARTIALLY BONDED BUILT UP FELT, MASTIC ASPHALT AND COLD

More information

floor TF70 Insulation INSULATION FOR SOLID CONCRETE AND SUSPENDED GROUND FLOORS

floor TF70 Insulation INSULATION FOR SOLID CONCRETE AND SUSPENDED GROUND FLOORS Insulation CI/Sfb Rn7 M2 Fifth Issue May 2007 floor TF70 INSULATION FOR SOLID CONCRETE AND SUSPENDED GROUND FLOORS High performance rigid urethane insulation thermal conductivity 0.023 W/m.K No requirement

More information

Monocouche Best Practice Guide. New-Build Housing Managing movement to avoid cracking

Monocouche Best Practice Guide. New-Build Housing Managing movement to avoid cracking Monocouche Best Practice Guide New-Build Housing Managing movement to avoid cracking Avoiding Cracking For The Designer Visible cracks in render are unsightly and although not hazardous to the construction

More information

INTERIOR WALLS AND BASEMENTS CHOOSING THE RIGHT MEMBRANE FOR INTERIOR WALLS. Multi-Layer Technology provides increased strength.

INTERIOR WALLS AND BASEMENTS CHOOSING THE RIGHT MEMBRANE FOR INTERIOR WALLS. Multi-Layer Technology provides increased strength. INTERIOR WALLS AND BASEMENTS CHOOSING THE RIGHT MEMBRANE FOR INTERIOR WALLS Multi-Layer Technology provides increased strength. Specifically designed for interior applications. Compatible with most internal

More information

NRG 75 CRF NRG GREENBOARD WALL SYSTEM

NRG 75 CRF NRG GREENBOARD WALL SYSTEM NRG GREENBOARD WALL SYSTEM NRG Energy Efficient Building Systems is pleased to announce a revolution in lightweight cladding systems. NRG Building Systems is the first and only company to achieve CodeMark

More information

Sika Membran System For Sealing and Waterproofing Construction Gaps in Building Façades

Sika Membran System For Sealing and Waterproofing Construction Gaps in Building Façades Construction Sika For Sealing and Waterproofing Construction Gaps in Building Façades Waterproof and Airtight Flexible Seal Controlled Vapour Diffusion Bonds to any Building Substrate Prevents Interstitial

More information

Including. Rubershield-Pro. Breather Membrane

Including. Rubershield-Pro. Breather Membrane Including RubershieldPro Breather Membrane 2 Ruberoid produces a wide range of underslating membranes, primarily to be installed below tiles, slates or metal roofing providing a secondary barrier against

More information

Memtec Single Ply PVC Membrane Roofing and Waterproofing Technology. Modern Efficient Performance Cost Effective Flat Roofing Systems

Memtec Single Ply PVC Membrane Roofing and Waterproofing Technology. Modern Efficient Performance Cost Effective Flat Roofing Systems Memtec Single Ply PVC Membrane Roofing and Waterproofing Technology Modern Efficient Performance Cost Effective Flat Roofing Systems Introduction A complete range of Memtec Roofing and Waterproofing Single

More information

PRESTRESSED CONCRETE FLOORING BEAMS

PRESTRESSED CONCRETE FLOORING BEAMS PRESTRESSED CONCRETE FLOORING BEAMS TRIED & TRUSTED Introduction Established in 2001 TT Concrete Products Limited has become a prominent manufacturer of prestressed concrete flooring beams throughout the

More information

CI/SfB (31.9) BETTER BY DESIGN PRODUCT GUIDE COMPLETE GUIDE TO THE IG PRODUCT RANGE. www.iglintels.com

CI/SfB (31.9) BETTER BY DESIGN PRODUCT GUIDE COMPLETE GUIDE TO THE IG PRODUCT RANGE. www.iglintels.com CI/SfB (31.9) Hh2 BETTER BY DESIGN PRODUCT GUIDE COMPLETE GUIDE TO THE IG PRODUCT RANGE www.iglintels.com BETTER BY DESIGN IG produce the UK s largest range of steel lintels backed by industry leading

More information

Insulated Roof & Wall Panels. Product Data Sheet. Trapezoidal Insulated Roof Panels KS1000 RW

Insulated Roof & Wall Panels. Product Data Sheet. Trapezoidal Insulated Roof Panels KS1000 RW Insulated Roof & Wall Panels Trapezoidal Insulated Roof Panels KS1000 RW Overview Kingspan roof panel systems present a superior system compared to conventional multi-part site assembled systems. They

More information

Energy Company Obligation (ECO): Technical Monitoring Questions

Energy Company Obligation (ECO): Technical Monitoring Questions Energy Company Obligation (ECO) Technical Monitoring Questions v1 30/05/2013 Energy Company Obligation (ECO): Technical Monitoring Questions Under ECO suppliers are required to instruct suitably qualified

More information

Sixth Issue March 2012. Kingspan. Building System. CERTIFICATE No. 02/0158. Low Energy - Low Carbon Buildings

Sixth Issue March 2012. Kingspan. Building System. CERTIFICATE No. 02/0158. Low Energy - Low Carbon Buildings Engineered Timber Systems Sixth Issue March 2012 Kingspan INFORMATION FOR SELF BUILDERS Building System CERTIFICATE No. 02/0158 Low Energy - Low Carbon Buildings Intelligent Design for a Smart Future You

More information

!!!!!! !!! Decra Plus DPSW010 DPSTW011 DPSW012 DPSW013 DPSW014 DPSW015 DPSW016 DPSW020 DPSW021 DPSW024 DPSW030 DPSW031 DPSW035 DPSW030 DPSW031 DPSW035

!!!!!! !!! Decra Plus DPSW010 DPSTW011 DPSW012 DPSW013 DPSW014 DPSW015 DPSW016 DPSW020 DPSW021 DPSW024 DPSW030 DPSW031 DPSW035 DPSW030 DPSW031 DPSW035 Decra Plus Drawing no DPSW010 DPSTW011 DPSW012 DPSW013 DPSW014 DPSW015 Description Shown In Decra Brochure Most Commonly Used Detail t~êã=oççñ=b~îéë=aéí~áä=b~îéë=lîéêü~åö=táíü=fåëìä~íéç=c~ëåá~=~åç=pçññáí

More information

FIRE RATED GLAZING System Guide

FIRE RATED GLAZING System Guide SYSTEM GUIDE Issue date: 05-05-2015 Expiry date: 31-12-2016 System Guide Introduction Pyropanel Developments are specialists in fire rated glazing solutions, and our systems are designed for easy installation

More information

ENVIRONMENTAL INFORMATION APR 1200 products are made from glass mineral wool, one of the most environmentally friendly insulants available.

ENVIRONMENTAL INFORMATION APR 1200 products are made from glass mineral wool, one of the most environmentally friendly insulants available. APR 1200 Acoustic Partition Roll CI/Sfb Ref: APR002 Glass mineral wool roll designed to provide high levels of sound insulation in walls and floors to meet Part E (England & Wales) and Section 5 (Scotland)

More information

PB301 July 2009. Lightweight Building Solutions. Bushfire Protection. www.boral.com.au/bushfireprotection

PB301 July 2009. Lightweight Building Solutions. Bushfire Protection. www.boral.com.au/bushfireprotection PB301 July 2009 Lightweight Building Solutions Bushfire Protection www.boral.com.au/bushfireprotection Attached or adjacent within 6m roofed structures such as garages, carports, verandas and the like,

More information

BUILDING CONTROL GUIDANCE SHEET USE OF BREATHABLE ROOFING FELTS.

BUILDING CONTROL GUIDANCE SHEET USE OF BREATHABLE ROOFING FELTS. Building Control Charnwood Borough Council Southfield Road Loughborough LE11 2TN BUILDING CONTROL GUIDANCE SHEET USE OF BREATHABLE ROOFING FELTS. Last updated 16/11/2010 Page 1 of 6 PURPOSE: This Guidance

More information

Innovation - High performance roof, wall and floor insulation board. delivering better performance

Innovation - High performance roof, wall and floor insulation board. delivering better performance 2010 VERSION 1 IRL High performance roof, wall and floor insulation board Innovation - delivering better performance PRODUCT SPECIFICATION INSTALLATION GUIDE I ve worked with Xtratherm for years, they

More information

FLAT ROOF INSULATION INSULATION ROOFING FLAT. Quick Guide. Quick Guide. Insulation. EcoTherm Insulation UK Sales Team. Insulation

FLAT ROOF INSULATION INSULATION ROOFING FLAT. Quick Guide. Quick Guide. Insulation. EcoTherm Insulation UK Sales Team. Insulation Insulation Insulation Scotland & North England 07824 412579 North West & North Wales 07931 342948 South Wales & West Midlands 07940 546247 Yorkshire & East Midlands 07825 570100 FLAT ROOF INSULATION EcoTherm

More information

SIG SIG CAVITY WALL INSULATION

SIG SIG CAVITY WALL INSULATION SIG 6 Park Square Thorncliffe Park Chapeltown Sheffield S35 2PH Tel: 0844 5766 762 Fax: 0114 240 9540 e-mail: cwi@sigplc.co.uk website: www.siginsulations.co.uk APPROVAL INSPECTION TESTING CERTIFICATION

More information

Dubai Municipality Standard DMS 1: Part 5: 2004

Dubai Municipality Standard DMS 1: Part 5: 2004 Specification for precast concrete blocks Part 5: Normal-weight concrete-polystyrene sandwich masonry blocks Issue Date Revision Revision Description Prepared by Approved by Authorized by 19/12/2004 Issue

More information

CI SfB. (4-) Nn2. Onduline. Mini Profile. Onduline Garden Roof Range. Onduline Building Products Ltd

CI SfB. (4-) Nn2. Onduline. Mini Profile. Onduline Garden Roof Range. Onduline Building Products Ltd CI SfB (4-) Nn2 Onduline Mini Profile Onduline Garden Roof Range Onduline Building Products Ltd Onduline Garden Roof Range Onduline Mini Profile The new Onduline Mini Profile sheets have been designed

More information

Composite Panel Firewall Systems

Composite Panel Firewall Systems Composite Panel Firewall Systems part of the Protecting more than your business Insulated mineral fibre panels have excellent thermal and acoustic properties, ideal for factory and office partition walls.

More information

COMMERCIAL BUILDING APPLICATIONS

COMMERCIAL BUILDING APPLICATIONS EXPANDED POLYSTYRENE FOR COMMERCIAL BUILDING APPLICATIONS www.falconfoam.com Commercial Building Ap Expanded Polystyrene Insulation Falcon Foam leads the commercial building industry with products that

More information

Manual lifting and handling

Manual lifting and handling Manual lifting and handling When installing British Gypsum products and systems care should be taken to ensure that appropriate methods of handling and lifting are adopted. The following guidance details

More information

The WANZ Guide to Window Installation

The WANZ Guide to Window Installation The WANZ Guide to Window Installation as described in E2/AS1 Amendment 5 Ver. 1.1 Page 2 of 74 Contents Overview Page 5 Objective Page 5 Scope Page 5 Opening Preparation Page 7 Step P1 Preliminary Check

More information

Services Enclosures and Protected Shafts - Maintaining Compartmentation

Services Enclosures and Protected Shafts - Maintaining Compartmentation Introduction When a fire resisting element is used to provide fire compartmentation, every opening that allows services to pass through the element must be adequately protected by sealing, or fire stopping

More information

Ubiflex. Non-lead flashing system

Ubiflex. Non-lead flashing system Ubiflex Non-lead flashing system Ubiflex non-lead flashing Ubiflex is a non-lead waterproof flashing material which can be used in most applications where lead is traditionally used to provide a weatherproof

More information

GUIDANCE SHEET FOR CONSERVATORIES, SUNROOMS AND EXTENSIONS TO DWELLINGS.

GUIDANCE SHEET FOR CONSERVATORIES, SUNROOMS AND EXTENSIONS TO DWELLINGS. GUIDANCE SHEET FOR CONSERVATORIES, SUNROOMS AND EXTENSIONS TO DWELLINGS. This leaflet provides guidance on how to attain compliance with The Building (Amendment) Regulations (Northern Ireland) 2006, Part

More information

Cavity Drain R20 is manufactured from1.0mm thick black high density polyethylene with studs approximately 20mm high.

Cavity Drain R20 is manufactured from1.0mm thick black high density polyethylene with studs approximately 20mm high. CI/SfB Tn6 L6813 September 2013 RIW CAVITY DRAIN R20 R20 is manufactured from1.0mm thick black high density polyethylene with studs approximately 20mm high. Other systems are available for specific uses,

More information

Fire 2This Technical Bulletin has been commissioned by the UK SIP Association in

Fire 2This Technical Bulletin has been commissioned by the UK SIP Association in REV 1-12.12.11/TB002 Technical Bulletin Fire 2This Technical Bulletin has been commissioned by the UK SIP Association in conjunction with TRADA Technology and is intended to provide the reader with introductory

More information

The WANZ Guide to Window Installation

The WANZ Guide to Window Installation The WANZ Guide to Window Installation as described in E2/AS1 Amendment 5 2 of 60 Contents Overview 5 Objective 5 Scope 5 Opening Preparation 7 Step P1 Preliminary Check 8 Step P2 Cut the Underlay 9 Step

More information

CERTIFICATE OF APPROVAL No CF 5055 ARABIAN VERMICULITE INDUSTRIES

CERTIFICATE OF APPROVAL No CF 5055 ARABIAN VERMICULITE INDUSTRIES CERTIFICATE OF APPROVAL No CF 5055 This is to certify that, in accordance with TS00 General Requirements for Certification of Fire Protection Products The undermentioned products of 1 st Industrial Area,

More information

Interior Walls below and above ground OLDROYD THE ULTIMATE WATERPROOF MEMBRANE SYSTEM

Interior Walls below and above ground OLDROYD THE ULTIMATE WATERPROOF MEMBRANE SYSTEM P r o d u c t a p p l i c a t i o n s a n d t e c h n i c a l i n f o r m a t i o n 2 below and above ground V OLDROYD THE ULTIMATE WATERPROOF MEMBRANE SYSTEM V The flexible, fast and cost-effective answer

More information

SOUND INSULATION FOR EXTERIOR WALLS AND FACADE SYSTEMS

SOUND INSULATION FOR EXTERIOR WALLS AND FACADE SYSTEMS NOISE TECHNICAL FACT SHEET FACT SHEET 5 SOUND INSULATION FOR EXTERIOR WALLS AND FACADE SYSTEMS The sound insulation of exterior walls and roof-ceiling systems refers to their ability to reduce external

More information

Linea Weatherboard DIRECT FIX CONCRETE SLAB AND SOFFIT FIGURE 1

Linea Weatherboard DIRECT FIX CONCRETE SLAB AND SOFFIT FIGURE 1 Top plate Stud Soffit lining 45mm min nog Fix scotia bead Building underlay/james Hardie rigid air barrier Soffit Detail Building underlay/james Hardie rigid air barrier Bottom plate 25mm wide cant strip.

More information

Section 4.3. Separating Floors. Timber frame floor with I-Beams. Upgrading existing timber floor with new ceiling. Timber frame floor with

Section 4.3. Separating Floors. Timber frame floor with I-Beams. Upgrading existing timber floor with new ceiling. Timber frame floor with Section Separating Floors Timber frame floor with I-Beams Product: Earthwool Acoustic Roll and Floorfoam Easy Edge Strip Timber frame floor with solid timber joists Product: Earthwool Acoustic Roll and

More information

Rooflighting and Glazing

Rooflighting and Glazing POLYESTER SHEET Rooflighting and Glazing safelight ultra standard economy 02 Rooflighting and Glazing Trilite is a range of translucent fibre glass reinforced polyester rooflighting and glazing sheet,

More information

WARMFILL CAVITY WALL INSULATION WARMFILL CAVITY WALL INSULATION FOR MASONRY CAVITY WALLS

WARMFILL CAVITY WALL INSULATION WARMFILL CAVITY WALL INSULATION FOR MASONRY CAVITY WALLS Warmfill Limited Unit 5, Port of Larne Business Park Redlands Road Larne BT40 1AX Tel: 028 9042 8260 Fax: 028 9042 7641 e-mail: sales@warmfill.com website: www.warmfill.com APPROVAL INSPECTION TESTING

More information

Section 2.4. Built-up Metal Roofs. Rail and bracket system. Standing seam system. Bu02. Product: Earthwool FactoryClad range Bu01

Section 2.4. Built-up Metal Roofs. Rail and bracket system. Standing seam system. Bu02. Product: Earthwool FactoryClad range Bu01 Section Built-up Metal Roofs Rail and bracket system Product: Earthwool FactoryClad range Bu01 Standing seam system Product: Earthwool FactoryClad range and Earthwool Universal Slab Bu02 Built-up Metal

More information

0845 0098 980 www.nicholsonsts.com

0845 0098 980 www.nicholsonsts.com 0845 0098 980 www.nicholsonsts.com ROOFTRAK The IFP is revolutionising the way we fix things to roofs. Technical Director of a leading UK roofing system manufacturer The ROOFTRAK-IFP A revolutionary solution

More information

PART 1 GENERAL 1.1 SECTION INCLUDES

PART 1 GENERAL 1.1 SECTION INCLUDES J-1 Section 09110 Long Form Specification INTERIOR METAL STUD FRAMING This section includes lightweight, usually 0.036 inch (0.9 mm) thick or lighter, non-axial load bearing metal stud framing including

More information

Uniclass L31:N14:P7111 C1/SfB (16.9) Rn7 (J4) February 2008. Foundation Heave Protection

Uniclass L31:N14:P7111 C1/SfB (16.9) Rn7 (J4) February 2008. Foundation Heave Protection Uniclass L31:N14:P7111 C1/SfB (16.9) Rn7 (J4) February 2008 Foundation Heave Protection The safe, sure way to provide foundation protection Clayshield is the proven solution to protecting foundations against

More information

Multi-Foil reflective insulation SPACE SAVING U-VALUE AS LOW AS 0.16W/m 2 K LIGHTWEIGHT EASY TO FIX

Multi-Foil reflective insulation SPACE SAVING U-VALUE AS LOW AS 0.16W/m 2 K LIGHTWEIGHT EASY TO FIX Multi-Foil reflective insulation SPACE SAVING U-VALUE AS LOW AS 0.16W/m 2 K LIGHTWEIGHT EASY TO FIX TECHNICAL CHARACTERISTICS Multi-Foil Reflective Insulation Xfoil Range of insulation is designed to achieve

More information

INSTA-POLYPEARL CAVITY WALL INSULATION INSTA-POLYPEARL PLUS AND INSTA-POLYPEARL PLATINUM CAVITY WALL INSULATION

INSTA-POLYPEARL CAVITY WALL INSULATION INSTA-POLYPEARL PLUS AND INSTA-POLYPEARL PLATINUM CAVITY WALL INSULATION InstaFibre Ltd Insta House Ivanhoe Road Hogwood Business Park Finchampstead Wokingham Berkshire RG40 4PZ Tel: 0118 932 8811 Fax: 0118 932 8314 APPROVAL INSPECTION TESTING CERTIFICATION TECHNICAL APPROVALS

More information

Installation Window Building In Details

Installation Window Building In Details Installation Window Building In Details INSTALLATION Photo courtesy of Rowe Aluminium DATE: NOVEMBER 2009 REPLACES: AUGUST 2003 INSTALLATION Installation Replaces: Scale: NOT TO SCALE Vantage snap-on couplers

More information

Knauf Aquapanel Interior. Tile Backing. Cement board for wet areas. Will not deteriorate in water. Easy to score and snap

Knauf Aquapanel Interior. Tile Backing. Cement board for wet areas. Will not deteriorate in water. Easy to score and snap Tile Backing Will not deteriorate in water Easy to score and snap Resistant to mould and mildew Knauf Aquapanel Interior Cement board for wet areas Knauf Aquapanel Interior Cement Board Drywall for Wet

More information

Epdm Flat Roofing Systems

Epdm Flat Roofing Systems Epdm Flat Roofing Systems EDPM can be fully bonded, loose laid and ballasted or mechanically attached depending on the existing roof and its proposed usage. This applies to roofs to be refurbished and

More information

BLACK JACK ALL WEATHER ROOF COATING

BLACK JACK ALL WEATHER ROOF COATING PAGE: 1 of 6 PRINT DATE: 16/09/2004 BLACK JACK ALL WEATHER ROOF COATING DESCRIPTION BLACK JACK ALL WEATHER ROOF COATING is a solvent based, full bodied black brushable compound with added fibres for reinforcement.

More information

Building Control Guidance Note

Building Control Guidance Note Elements Renovation / Replacement. Issued 25/01/13 Rev a Page 1 of 9 (Applies to both Domestic and Non-Domestic Premises) Works relating to thermal elements can arise in building an extension, a material

More information

CERTIFICATE OF APPROVAL No CF 291 SCHOTT UK LIMITED

CERTIFICATE OF APPROVAL No CF 291 SCHOTT UK LIMITED CERTIFICATE OF APPROVAL No CF 291 This is to certify that, in accordance with TS General Requirements for Certification of Fire Protection Products The undermentioned products of Drummond Road, Stafford.

More information

Rev 1-12.2013. Code of Practice. SIP Technology. www.uksips.org

Rev 1-12.2013. Code of Practice. SIP Technology. www.uksips.org Rev 1-12.2013 Code of Practice SIP Technology www.uksips.org What are Structural Insulated Panels (SIPS)? SIPS are prefabricated, high performance, lightweight, building panels that can be used in floors,

More information

Understanding BS EN 771-3: Aggregate concrete masonry units

Understanding BS EN 771-3: Aggregate concrete masonry units 60 Charles Street, Leicester LE1 1FB Tel: 0116 253 6161 Fax: 0116 251 4568 Email: enquiries@cba-blocks.org.uk Website: www.cba-blocks.org.uk February 2006 Understanding BS EN 771-3: Aggregate concrete

More information

PRODUCT SHEET 1 MIDLAND LEAD MANUFACTURERS LTD S CAST LEAD SHEET

PRODUCT SHEET 1 MIDLAND LEAD MANUFACTURERS LTD S CAST LEAD SHEET CI/SfB (49) Mh8 Midland Lead Manufacturers Ltd Kiln Way Woodville Swadlincote Derbyshire DE11 8ED Tel: 01283 224555 Fax: 01283 550284 e-mail: sales@midlandlead.co.uk website: www.midlandlead.co.uk Agrément

More information

Providing protection in construction

Providing protection in construction Providing protection in construction VOLUME 2: WALLS AND FLOORS Contact Information UK office address: DuPont Tyvek Hither Green Trading Estate Clevedon, North Somerset BS21 6XU Tel: 01275 879770 Fax (sales):

More information

The right solutions. However, it is inevitable that with the introduction of any new construction system the question arises How does it compare?

The right solutions. However, it is inevitable that with the introduction of any new construction system the question arises How does it compare? Value assessment. The right solutions. We Believe We believe that Porotherm offers both short and long term value to all involved in the building process - from bricklayer to client and everyone in between.

More information

Improving thermal insulation of concrete sandwich panel buildings

Improving thermal insulation of concrete sandwich panel buildings Improving thermal insulation of concrete sandwich panel buildings Jørgen Munch-Andersen Danish Building Research Institute, Aalborg University LCUBE conference, Vienna 17-18 April 2007 Outline A general

More information

Installation Instructions

Installation Instructions Installation Instructions 1. Position the unit onto bridging packers. These keep the unit away from any water sitting inside the frame. 2. Centralise the unit within the frame and pack the edges with appropriate

More information

Poro Lintel System Range Unique to the Porotherm & thin joint masonary systems

Poro Lintel System Range Unique to the Porotherm & thin joint masonary systems Poro Lintel System Range Unique to the Porotherm & thin joint masonary systems keystonelintels.com Finding better ways to build for tomorrow The Keystone Group are Europe s leading steel lintel manufacturer.

More information

Residential Inspection Guidelines

Residential Inspection Guidelines Residential Inspection Guidelines 201 Pre-Pour Foundation Dimensions Building Location Certificate - if required in the building consent Construction and Advice Notes Check the building dimensions against

More information

Avoiding Air Barrier Pitfalls

Avoiding Air Barrier Pitfalls Avoiding Air Barrier Pitfalls Design & Durability November 2013 Air barriers, when correctly installed, help buildings achieve high levels of energy efficiency by decreasing heat loss. For example, great

More information

Formwork Direct International Ltd Phone No +44 (0151) 532 0179 Fax no +44 (0151) 523 8330 E-Mail: sales@formworkdirect.co.

Formwork Direct International Ltd Phone No +44 (0151) 532 0179 Fax no +44 (0151) 523 8330 E-Mail: sales@formworkdirect.co. Joint Fillers Formwork Direct are proud to be The UK and Ireland distributor for LJA Miers & Co. who have been responsible for many of the developments in Joint Fillers that are today accepted as common

More information

FLASHMAN WINDOW AND DOOR FLASHING SYSTEM. Product. Scope. Appraisal No. 573 [2013]

FLASHMAN WINDOW AND DOOR FLASHING SYSTEM. Product. Scope. Appraisal No. 573 [2013] FLASHMAN WINDOW AND DOOR FLASHING SYSTEM This Appraisal replaces BRANZ Appraisal No. 573 (2007). Amended 05 February 2016. BRANZ Appraisals Technical Assessments of products for building and construction.

More information

Tested to BS 6375: Part 1: 1989 and achieved a weathertightness classification of 2000 Pa (Special)

Tested to BS 6375: Part 1: 1989 and achieved a weathertightness classification of 2000 Pa (Special) THE B6 GLAZING SYSTEM GLAZING SYSTEMS FOR SEPTEMBER 2013 THE B6 HEEL BEAD SEAL SECURITY GLAZING SYSTEM Page 1 DESCRIPTION The B6 Heel Bead Seal Security Glazing System is suitable for installing all types

More information

SG Series 65mm Frame Windows (Fixed Lite Window Illustrated)

SG Series 65mm Frame Windows (Fixed Lite Window Illustrated) (Fixed Lite Window Illustrated) SINGLE LEAF CLADDING / CORRUGATED STEEL (Awning Window Illustrated) SINGLE LEAF CLADDING / FOAM BOARD (Casement Window Illustrated) BRICK VENEER CONSTRUCTION (Horizontal

More information

GigaCrete Specification PlasterMax

GigaCrete Specification PlasterMax GigaCrete Inc. 6775 Speedway Blvd. Suite M105 Las Vegas, NV 89115 Ph (702) 643-6363 Fax (702) 643 1453 www.gigacrete.com GigaCrete Specification PlasterMax PlasterMax : Fire Rated Plaster for Direct Application

More information

Comment Form on Proposed Gut Rehabilitation Alternatives

Comment Form on Proposed Gut Rehabilitation Alternatives Comment Form on Gut Rehabilitation Alternatives Name: Organization: Email: Instructions Submission: Please submit this form to energystarhomes@energystar.gov by October 10 th, 2012 with the subject line

More information

TFL CUSTOM FIREPLACES WITH MASONRY BRICK LININGS. standard INSTALLATION SPECIFICATION INTO TIMBER FRAMING

TFL CUSTOM FIREPLACES WITH MASONRY BRICK LININGS. standard INSTALLATION SPECIFICATION INTO TIMBER FRAMING 6.CW.1A TFL CUSTOM FIREPLACES WITH MASONRY BRICK LININGS wood or gas standard INSTALLATION SPECIFICATION INTO TIMBER FRAMING The Fireplace Ltd is able to design and fabricate custom brick open masonry

More information

Tunnels & Arches OLDROYD THE ULTIMATE WATERPROOF MEMBRANE SYSTEM

Tunnels & Arches OLDROYD THE ULTIMATE WATERPROOF MEMBRANE SYSTEM P r o d u c t a p p l i c a t i o n s a n d t e c h n i c a l i n f o r m a t i o n 5 Tunnels & Arches V OLDROYD THE ULTIMATE WATERPROOF MEMBRANE SYSTEM V Create dry usable space with the original X pattern

More information

BEST PRACTICE GUIDE. Fibrelime Premixed Universal Plaster and Render

BEST PRACTICE GUIDE. Fibrelime Premixed Universal Plaster and Render BEST PRACTICE GUIDE Fibrelime Premixed Universal Plaster and Render Contents: Fibrelime description Fibrelime suitability Preparation before application Application Aftercare Painting General Recommended

More information

Installation Instructions

Installation Instructions Installation Instructions Pedestal Models FS 500 LE FS 800 LE Insert Models IS 500 LE IS 800 LE Pecan Engineering Pty Ltd 13 Acorn Road Dry Creek South Australia 5094 Email info@pecan-eng.com.au Phone:

More information

WINDOW INSTALLATION GUIDE FOR NEW CONSTRUCTION - WOOD FRAMING

WINDOW INSTALLATION GUIDE FOR NEW CONSTRUCTION - WOOD FRAMING WINDOW INSTALLATION GUIDE FOR NEW CONSTRUCTION - WOOD FRAMING IMPORTANT NOTICES AND INFORMATION Read these instructions in their entirety prior to installing windows. Any local building code requirements

More information

GYPSUM AREA SEPARATION FIREWALLS GA-620-2011

GYPSUM AREA SEPARATION FIREWALLS GA-620-2011 GYPSUM AREA SEPARATION FIREWALLS GA-620-2011 GA-620-2011 Copyright 2011 Gypsum Association All rights reserved. Printed in U.S.A. Characteristics, properties, or performance of materials or systems herein

More information