USB ADAPTER PLUS Quick Start
|
|
- Monica Stevenson
- 7 years ago
- Views:
Transcription
1 USB ADAPTER PLUS Quick Start Configuration tool for: IFC 100 / 300 (with Pactware) BATCHFLUX 5500 C (with BatchMon Plus) IFC 010 / 090 / 110 and BATCHFLUX 5012 C / 5015 C (with ImoMon Plus) KROHNE
2 CONTENTS USB ADAPTER PLUS 1 General description 3 2 Operation IFC IFC BATCHFLUX 5500 C Converters with ImoCom Notes 13 2
3 USB ADAPTER PLUS GENERAL DESCRIPTION 1 The USB-Adapter Plus is an adapter to read / write all kind of data to many different converters. The following overview shows you which parts and software you need: Signal converter Cable Software IFC 100 and IFC 300 BATCHFLUX 5500 C BATCHFLUX 5500 C with status output Old ImoCom converters, eg BATCHFLUX 5015, IFC 010 Standard cable dubox 2x3-pole > dubox 2x4-pole or IR interface cable Optional cable M12 5-pole > dubox 2x4-pole Optional T-connector M12 5-pole Optional cable M12 8-pole > dubox 2x4-pole Optional T-connector M12 8-pole Optional cable dubox 1x5-pole > 2x4-pole Pactware + DTM + GDC drivers BatchMon Plus ImoMon Plus The scope of delivery includes the USB-Adapter Plus, the cable needed for IFC 100 / 300 and the printed documentation. Optionally you receive a set of connection cables / connectors for connection to BATCHFLUX 5500 and old ImoCom type converters. 3
4 2 OPERATION USB ADAPTER PLUS 2.1 IFC 100 As described in the previous chapter, the USB-Adapter Plus can be used in three ways. Each way is described in a separate section. The standard delivery includes all items you need to use it with an IFC 100 signal converter. Figure 2-1: Connection of adapter to the GDC bus of the IFC Connection room of IFC Cable 2x3-pole > 2x4-pole 3 USB-Adapter Plus Needed software: GDC driver IFC 100 HART DTM Pactware configuration tool INFORMATION! All relevant tools are on the CD and on the website of the manufacturer. Connect the USB connector to your PC, start the relevant program and follow the instructions given on the display. Refer to the documentation of the signal converter for a description of the menu. 4
5 USB ADAPTER PLUS OPERATION IFC 300 The standard delivery includes all items you need to use it with an IFC 300 signal converter. with GDC connection cable Figure 2-2: Connection of adapter to the GDC bus of the IFC Connection room of IFC Cable 2x3-pole > 2x4-pole 3 USB-Adapter Plus with IR interface cable Figure 2-3: Connection of adapter to the IR interface of the IFC Display of IFC IR Interface cable 3 USB-Adapter Plus Needed software: GDC driver IFC 300 HART DTM Pactware configuration tool INFORMATION! All relevant tools are on the CD and on the website of the manufacturer. Connect the USB connector to your PC, start the relevant program and follow the instructions given on the display. Refer to the documentation of the signal converter for a description of the menu. 5
6 2 OPERATION USB ADAPTER PLUS 2.3 BATCHFLUX 5500 C CAUTION! The T-connectors and the cables ( M12 5-pole / 8-pole) are available as an optional package. To order the specific cables notice the items 2, 3 and 5 in the illustration below Figure 2-4: Connection of adapter to the BATCHFLUX 5500 C V supply (to be provided by customer) 2 T-connector (optional); M12 5-pole M12 8-pole (for BATCHFLUX 5500 C with status output) 3 BATCHFLUX 5500 C connector M12 5-pole M12 8-pole (for BATCHFLUX 5500 C with status output) 4 USB-Adapter Plus (standard) 5 Optional cable; M12 5-pole -> 2x4-pole M12 8-pole -> 2x4-pole (for BATCHFLUX 5500 C with status output) Needed software: BatchMon Plus 6
7 USB ADAPTER PLUS OPERATION 2 INFORMATION! All relevant tools are on the website of the manufacturer. Installation procedure: Do NOT connect the USB adapter yet. Install the software KROHNE BatchMon Setup Version 3.x.x. Ignore any error messages about Windows certificates. Connect the USB cable to the computer. The wizard "New hardware found" starts. - Choose "Not now", click 1x on "Next". - Screen "Hardware" opens, click 2x on "Continue". - If hardware is detected, click on "Finish". Message shows "Hardware can be used". Start the BatchMon Plus program once. Close the program and start it again. In the menu, the function "On-line processing" is now enabled. INFORMATION! Next time, just connect the USB-Adapter Plus and start the program. The menu of the BATCHFLUX 5500 C is given on the next pages. 7
8 2 OPERATION USB ADAPTER PLUS Menu C1: Process input No. Function / subfunction Settings / descriptions C1.1 Calibration C1.1 Calibration C1.1.1 Zero calibration Measured zero point (m/s). Use the "calibration" button to calculate a new zero. Calibration procedure takes 30 seconds. C1.1.2 Size entry selection Value (mm), Table (mm, inch) For "Value": manual input of flow meter size in box For "Table": choose from pull down menu in box C1.1.5 GK selection GK, GKL For "GK": value is shown in box For "GKL": value is shown in box C1.1.8 Coil resistance Ω Configured, can be changed. C1.1.9 Field frequency 1/6...2 * line frequency Choose from pull down menu Select settling Standard (predefined), Manual Settling time 0, ,25 (s) Manual input Line frequency 50 or 60 Hz Measurement conductivity Off, On Off: Default Number values Number of measurements taken to calculate the average conductivity (if is switched on). 8
9 USB ADAPTER PLUS OPERATION 2 C1.2 Filter C1.2 Filter C1.2.1 Min. limitation ,001 (m/s) Menu C2: Inputs/outputs (I/O's) The output freezes at this value. C1.2.2 Max. limitation 0, (m/s) The output freezes at this value. C1.2.3 Flow direction Normal direction (default), Reverse direction C1.2.4 Time constant (s) Manual input C1.2.5 Low flow cut off threshold (m/s) C1.2.6 C1.3 Information Low flow cut off hysteresis C1.3 Information Manual input (m/s) Manual input No. Function / subfunction Settings / descriptions C2.1 Hardware C2.1.0 Hardware Frequency output, Pulse output C2.1.1 Terminals D Program frequency output in submenu Program pulse output in submenu C2.2 Frequency output (if selected in "hardware") C2.2.1 Pulse shape Symmetric, Fixed, Automatic (default) C2.2.2 Pulse width 5E (s) C % pulse rate 0, (Hz) C2.2.4 Range min. -1E E +30 (m 3 /s) Manual input. C2.2.5 Range max. -1E E +30 (m 3 /s) Manual input. C2.2.6 Polarity Both polarity, Positive polarity (default), Negative polarity, Absolute polarity C2.2.7 Limitation min. -1E E +30 (%) C2.2.8 Limitation max. -1E E +30 (%) C2.2.9 Low flow cut off threshold (%) Manual input. C Low flow cut off hysteresis (%) Manual input. C Time constant (s) C Invert signal Off (default), On 9
10 2 OPERATION USB ADAPTER PLUS No. Function / subfunction Settings / descriptions C Delay low flow cutoff [s] Menu C3: Device Manual input. C2.2 Pulse output (if selected in "hardware") C2.2.1 Pulse shape Symmetric, Fixed, Automatic (default) C2.2.2 Pulse width 5E (s) C2.2.6 Polarity Both polarity, Positive polarity (default), Negative polarity, Absolute polarity C Time constant (s) C Invert signal Off (default), On C Max. pulse rate 0, (Hz) C Value per pulse -1E E +30 (m 3 ) C Low flow cut off threshold -1E E +30 (m 3 /s) Manual input C Low flow cut off -1E E +30 (m 3 /s) hysteresis Manual input C Delay low flow cutoff [s] Manual input. C2.3 Status output (not available in BATCHFLUX 5500 C Standard version) C2.3.1 Mode Off, error, flow direction (default) C2.3.2 Invert signal Off (default), on No. Function / subfunction Settings / descriptions C3.1 Units C3.1.1 Volume flow l/s, l/min, l/h, m 3 /s, m 3 /min, m 3 /h, ft 3 /s, ft 3 /min, ft 3 /h, gal/s, gal/min, gal/h, lg/min, lg/h, free unit When you choose "free unit" two additional boxes will appear: box (text free unit) and box (m 3 /s * factor). With this factor the BATCHFLUX will calculate the right value for your free unit. C3.1.4 Volume ml, l, hl, m 3, in 3, ft 3, yd 3, gal, lg, free unit When you choose free unit two additional boxes will appear: box (text free unit) and box (m 3 * factor). With this factor the BATCHFLUX will calculate the right value for your free unit. C3.1.7 Flow speed ft/s, m/s (default) 10
11 USB ADAPTER PLUS OPERATION 2 Menu C4: Service No. Function / subfunction C4.1 Oscillograph Horizontal axis is the quantity of collected values. Vertical axis is the flow rate in liters per seconde C4.2 Sensor values C4.2.1 Flow velocity C4.2.2 DC voltage electrode 2 C4.2.3 DC voltage electrode 3 C4.2.4 Electronic temperature C4.2.5 Field current settling time C4.2.6 Field current resistance C4.2.7 Status sensor C4.2.8 Status starting phase C4.2.9 Status warnings C Status fatal C Status field current C Coil temperature C Conductivity C4.3 Information C4.3.1 Operating hour meter Days, hours, minutes 11
12 2 OPERATION USB ADAPTER PLUS 2.4 Converters with ImoCom Old converters can be used if they have an ImoCom connector on board. Some possibilities are shown below. Figure 2-5: 1 BATCHFLUX 5012 C / 5015 C flowmeter 2 IFC 010 signal converter 3 IFC 090 signal converter 4 IFC 110 signal converter 5 USB-Adapter Plus 6 Optional cable (1x5-pole connector > 2x4-pole connector) CAUTION! Please note that ".net Framework 2.0" is installed before installation (part of Windows XP service pack 2). The ImoCom cable 1x5-pole connector > 2x4-pole connector is available as an optional package. Needed software: ImoMon Plus INFORMATION! All relevant tools are on the CD and on the website of the manufacturer. Connect the USB connector to your PC, start the relevant program and follow the instructions given on the display. 12
13 USB ADAPTER PLUS NOTES 3 13
14 3 NOTES USB ADAPTER PLUS 14
15 USB ADAPTER PLUS NOTES 3 15
16 KROHNE product overview KROHNE - Subject to change without notice. Electromagnetic flowmeters Variable area flowmeters Ultrasonic flowmeters Mass flowmeters Vortex flowmeters Flow controllers Level meters Temperature assemblies Pressure transmitters Analysis products Products and systems for the oil & gas industry Measuring systems for the marine industry Head Office KROHNE Messtechnik GmbH Ludwig-Krohne-Str Duisburg (Germany) Tel.: Fax: info@krohne.com The current list of all KROHNE contacts and addresses can be found at:
IFC 070 Technical Datasheet
IFC 070 Technical Datasheet Electromagnetic signal converter Battery driven with low energy consumption Quick and easy to install and operate External data logger and GSM module for remote data transfer
More informationTransmitter Interface Program
Transmitter Interface Program Operational Manual Version 3.0.4 1 Overview The transmitter interface software allows you to adjust configuration settings of your Max solid state transmitters. The following
More informationSeries DFMT Digital Paddlewheel Flowmeter
Series DFMT Digital Paddlewheel Flowmeter Bulletin F-DFMT Specifications - Installation Operating Instructions -/8 [00] -/ [8] -/8 [00] A The Series DFMT Digital Paddlewheel Flow Transmitter provides instantaneous
More informationJUMPFLEX 857 Series. 0...20 ma 2...10 V. 4...20 ma. Transducers / Relay and Optocoupler Modules
0888-0172/0002-3601 JUMPFLEX 857 Series 2.0 E 12/08 Printed in Germany Subject to design changes 2...10 V 0...20 ma 4...20 ma WAGO Kontakttechnik GmbH & Co. KG Postfach 2880 32385 Minden Hansastraße 27
More informationPhysical Specifications (Custom design available.)
Helmholtz Coils A useful laboratory technique for getting a fairly uniform magnetic field, is to use a pair of circular coils on a common axis with equal currents flowing in the same sense. For a given
More informationContents. Document information
User Manual Contents Document information... 2 Introduction... 3 Warnings... 3 Manufacturer... 3 Description... Installation... Configuration... Troubleshooting...11 Technical data...12 Device Scope: PCB
More informationInstruction Manual Service Program ULTRA-PROG-IR
Instruction Manual Service Program ULTRA-PROG-IR Parameterizing Software for Ultrasonic Sensors with Infrared Interface Contents 1 Installation of the Software ULTRA-PROG-IR... 4 1.1 System Requirements...
More informationMeasurement. SITRANS F US Inline. Transmitter FUS080/FUE080 4/219
Siemens AG 2010 Flow Measurement Overview The transmitter is available in an IP67/NEMA X/6 enclosure and is designed for use in the flowmeters series: SONOKIT (1- or 2-track) FUS380 (2-track) FUE380 (2-track)
More informationPC Software for VAV compact and modular controllers
s 5 854 OpenAir PC Software for VAV compact and modular controllers ACS941 for use with GDB/GLB/ASV181 For Version 3.02 The ACS941 software is used for setting and displaying the parameter values with
More informationEVAL-UFDC-1/UFDC-1M-16
Evaluation Board for Universal Frequency-to- Digital Converters UFDC-1 and UFDC-1M-16 EVAL-UFDC-1/UFDC-1M-16 FEATURES Full-Featured Evaluation Board for the Universal Frequency-to-Digital Converters UFDC-1
More informationDuct Humidity Transmitter
SDC-H Duct Humidity Transmitter Features Replaceable sensor element Humidity measurement for air ducts Minimum and maximum value memory 0 0V, 0 0mA or 0V, 4 0mA measuring signals selectable with jumpers
More informationModular I/O System Analog and Digital Interface Modules
OPERATING INSTRUCTIONS Modular I/O System Analog and Digital Interface Modules Installation Operation Maintenance Document Information Document ID Title: Operating Instructions Modular I/O System Part
More informationDAKTON µ BOX MANUAL µbox User Manual 1
µbo User Manual 1 DAKTON µ BO: compact data logger and sensor µ BO is a sensor and a data logger together. It records data processed by DAKTON DASHBOARD with the addition of lateral and longitudinal accelerations.
More informationHow To Use An Ams 5812 Pressure Sensor With A Usb Starter Kit
User Guide USB Starter Kit AMS 5812 Phone:+49 (0)6131/91 0730-0 Fax: +49 (0)6131/91 073-30 Internet: E Mail: info@analogmicro.de Analog Microelectronics GmbH An der Fahrt 13, D 55124 Mainz May 2012 - Rev.
More informationMCR-VDC-UI-B-DC. Voltage Transducer for DC Voltages. INTERFACE Data Sheet 100260_en_01. 1 Description
Voltage Transducer for DC Voltages TERFACE Data Sheet 000_en_0 PHOENIX CONTACT - /00 Description The MCR voltage transducer measures DC voltages in several signal ranges from 0... ±0 V DC to 0... ±0 V
More informationOPERATING MANUAL. Table of contents. 2 Phase Stepping Motor Driver 2M542. Rev. A. Introduction page 2. Specifications page 2 Timing chart page 3
2 Phase Stepping Motor Driver 2M542 OPEATING MANUAL Table of contents Introduction page 2 Specifications page 2 Timing chart page 3 Setting page 4 Current set page 4 educe current function page 4 Micro
More informationElectro-Magnetic Flowmeters COPA-XT 2-Wire DT43
Data Sheet Electro-Magnetic Flowmeters COPA-XT 2-Wire DT43 2-Wire Operation Significantly reduces installation costs when compared to a traditional 4-wire magmeter. ±0.5% of rate system accuracy. Patented
More informationWinLIN Setup and Operation:
Frequently Asked Questions about the 07551-Series Masterflex L/S Computer-Compatible drives and about the Masterflex WinLIN Linkable Instrument Control Software (07551-70) WinLIN Setup and Operation: Will
More informationInstalling the Gerber P2C Plotter USB Driver
Installing the Gerber P2C Plotter USB Driver 1 You can install a Gerber P2C plotter using a USB connection and communicate with it using compatible design software. The following procedures describe installing
More informationOPTIMASS 1400 Technical Datasheet
OPTIMASS 1400 Technical Datasheet Sensor for mass flow First choice for universal applications Best price-performance ratio A wide range of options available with no restrictions The documentation is only
More informationHow to use the OMEGALOG software with the OM-SQ2010/SQ2020/SQ2040 Data Loggers.
How to use the OMEGALOG software with the OM-SQ2010/SQ2020/SQ2040 Data Loggers. OMEGALOG Help Page 2 Connecting Your Data Logger Page 2 Logger Set-up Page 3 Download Data Page 8 Export Data Page 11 Downloading
More informationWideband USB Synthesized Signal Generator. Dynamic range 70 db, output power from -60dBm to +10dBm in 0.25dB steps
Wideband USB Synthesized Signal Generator 50Ω -60 dbm to +10 dbm, 25-6000 MHz The Big Deal Wideband generator with 3 Hz frequency resolution 70dB adjustable output power range Internal pulse modulation
More informationHYDRUS ULTRASONIC METER
HYDRUS APPLICATION HYDRUS is a static water meter based on the ultrasonic technology. This technology enables accurate calculation of water consumption and eliminates measuring deviations caused by sand,
More informationDigital and Analog I/O
70072-0127-07 TECHNICAL NOTE 02/2007 Digital and Analog I/O This document discusses the application and configuration of digital and analog inputs/outputs (I/O). Details are for both onboard I/O and external
More informationManual. PC-Software Save`n carry PP 50 pro
Manual PC-Software Save`n carry PP 50 pro Directory 1 Directory 1 Directory... 2 2 Introduction... 3 2.1 Product description... 3 2.2 Pictograms... 3 2.3 Software installation... 4 2.4 Hardware installation...
More informationIDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODELS: 61-763 61-765
IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODELS: 61-763 61-765 The Service Information provides the following information: Precautions and safety information Specifications Performance test procedure Calibration
More informationSHARKY 775 COMPACT ENERGY METER ULTRASONIC
APPLICATION The ultrasonic compact energy meter can be used for measuring the energy consumption in heating / cooling application for billing purposes. FEATURES 4 Approval for ultrasonic meter with dynamic
More informationUser Manual for CH-PFC76810
AA Portable Power Corp www.batteryspace.com, Email: Sales@batteryspace.com User Manual for CH-PFC76810 1. Overview The CH-PFC76810 charger is suitable for charging lithium ion battery packs such as those
More informationProduct Information. Gateway For Connecting EnDat Encoders to PROFIBUS-DP
Product Information Gateway For Connecting EnDat Encoders to PROFIBUS-DP April 2012 PROFIBUS Gateway For Connecting EnDat Encoders Encoders with EnDat interface for connection via gateway All absolute
More informationTechnical Manual. FAN COIL CONTROLLER COOLING or HEATING ANALOG or PWM Art. 119914 631001A
COOLING or HEATING ANALOG or PWM Art. 119914 631001A TOTAL AUTOMATION GENERAL TRADING CO. LLC SUITE NO.506, LE SOLARIUM OFFICE TOWER, SILICON OASIS, DUBAI. UAE. Tel. +971 4 392 6860, Fax. +971 4 392 6850
More informationSENSORS. Fiber Optic Sensors - S70. Advanced fiber optic amplifiers for high speed and low contrast applications
Fiber Optic Sensors - S7 Advanced fiber optic amplifiers for high speed and low contrast applications DIN rail mountable models with dual digital displays speed models: 2 μs...5 ms Super high speed models:
More informationUSB Drivers Getting Started Guide
USB Drivers Getting Started Guide PC version US Edition TP-1522-US Issue 2 All rights reserved All information contained in this document is subject to change without notice. Any use of the contents of
More informationCurrent Monitoring Kit
Current Monitoring Kit QUICK START GUIDE DO090-6 CONTENTS Issues: 1) 2.10.02 WP A4 format 2) 2.10.02 Added safety warning 3) 17.3.06 Word A5 format. S1: Removed relay modules. S2: Added MI010. S4.1: added
More informationScanWin Installation and Windows 7-64 bit operating system
ScanWin Installation and Windows 7-64 bit operating system In order to run the ScanWin Pro install and program on Windows 7 64 bit operating system you need to install a Virtual PC and then install a valid,
More informationT7560A,B,C Digital Wall Module
T7560A,B,C Digital Wall Module HONEYWELL EXCEL 5000 OPEN SYSTEM BEFORE INSTALLATION All wiring must comply with local electrical codes and ordinances or as specified on installation wiring diagrams. Digital
More informationSNMP Web Management. User s Manual For SNMP Web Card/Box
SNMP Web Management User s Manual For SNMP Web Card/Box Management Software for Off-Grid Inverter Version: 1.2 Table of Contents 1. Overview... 1 1.1 Introduction... 1 1.2 Features... 1 1.3 Overlook...
More informationSetup guide IM/WM/VM EN Rev. B. VeriMaster Software tools
Setup guide IM/WM/VM EN Rev. B VeriMaster The Company We are an established world force in the design and manufacture of instrumentation for industrial process control, flow measurement, gas and liquid
More information22X DSP COLOR ZOOM CAMERA AUTO FOCUS ZOOM CAMERA
Instruction Manual 22X DSP COLOR ZOOM CAMERA AUTO FOCUS ZOOM CAMERA OPERATION / INSTALLATION MANUAL Thank you for using this product. Please read this manual carefully before use, Please keep this instruction
More informationWeb Datalogger. Unit RS232C. General-purpose modem RS485. IP address search screen
Equipment, facilities, and service networks for data collection/logging, data transfer via e-mail/website, and system streamlining can be established without special knowledge. Energy saving system in
More informationFor Multi-Parameter Meters see mvx
BULLETIN BULLETIN EM20607 VORTEX IN-LINE FLOW METERS Design Features For Multi-Parameter Meters see m Principles of Operation n No moving parts to wear or fail. n Electronics can be remotely mounted up
More informationUSB Smart Power Sensor
50Ω -30 dbm to +20 dbm, 9 khz to 4000 MHz The Big Deal Low cost USB HID device compatible with 32/64 Bit operating systems Includes Measurement Application GUI (Graphical User Interface) software with
More informationOperating instructions Switching amplifier for fibre optics. OBF5xx 704876 / 00 08 / 2010
Operating instructions Switching amplifier for fibre optics OBF5xx 70876 / 00 08 / 00 Contents Preliminary note. Symbols used Functions and features. Applications Installation. Attaching the fibre optics
More informationWINDOW's Programming Software USER MANUAL
www.danahermotion.com High frequency inverter ACO5000 by ACOMEL WINDOW's Programming Software USER MANUAL DANAHER MOTION S.A. La Pierreire 2, CH-1029 Villars-Ste-Croix Telephone +41 21 631 33 33, Telefax
More informationUSB VoIP Phone Adapter. User s Manual
USB VoIP Phone Adapter User s Manual FCC Certifications This Equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 and part 68 of the FCC Rules.
More informationImpedance 50 (75 connectors via adapters)
VECTOR NETWORK ANALYZER PLANAR TR1300/1 DATA SHEET Frequency range: 300 khz to 1.3 GHz Measured parameters: S11, S21 Dynamic range of transmission measurement magnitude: 130 db Measurement time per point:
More informationSITRANS F M MAGFLO. Electromagnetic flowmeters Signal converter types MAG 5000, MAG 6000. Manual *083R9141* Order no.
s Manual SITRANS F M MAGFLO Electromagnetic flowmeters Signal converter types MAG 5000, MAG 6000 [ ] Order no.: FDK:521H0739 DKFD.PS.027.Z4.02 - A5E00253213 *083R9141* 1. Technical data 1.1 Signal converter
More informationS O F T W A R E M A N U A L FLOWSIC600. Ultrasonic Gas Flow Meter II + Analyzers and Process Instrumentation
S O F T W A R E M A N U A L FLOWSIC600 II + Analyzers and Process Instrumentation Software Manual FLOWSIC600 Content About this document...5 1 Safety instructions...6 2 General...9 2.1 Installation...9
More informationWaterMAG. Electromagnetic Flowmeter for Water Applications. Model MCB10A OVERVIEW APPLICATIONS FEATURES. No. SS2-MCB100-0100
WaterMAG Electromagnetic Flowmeter for Water Applications OVERVIEW The WaterMAG is an electromagnetic flowmeter for water measurement applications based on field proven Azbil Corporation's technologies.
More information1. Learn about the 555 timer integrated circuit and applications 2. Apply the 555 timer to build an infrared (IR) transmitter and receiver
Electronics Exercise 2: The 555 Timer and its Applications Mechatronics Instructional Laboratory Woodruff School of Mechanical Engineering Georgia Institute of Technology Lab Director: I. Charles Ume,
More informationBerkeley Audio Design Alpha USB
QUICK USER GUIDE v1.2.2 Berkeley Audio Design Alpha USB The Alpha USB is an asynchronous High Speed USB to digital audio interface designed to provide the highest possible audio quality from computer audio
More informationEPSON Perfection 1650/1650 PHOTO. Scanner Parts. Scanner Specifications. Basic Specifications. device Effective pixels
Scanner Parts Start and indicator light Photo Print USB port The has a transparency unit built into the scanner lid and holder for 35 mm film and slides: EPSON Perfection 1650 owners can purchase an optional
More informationTHERMAL ANEMOMETRY ELECTRONICS, SOFTWARE AND ACCESSORIES
TSI and TSI logo are registered trademarks of TSI Incorporated. SmartTune is a trademark of TSI Incorporated. THERMAL ANEMOMETRY ELECTRONICS, SOFTWARE AND ACCESSORIES IFA 300 Constant Temperature Anemometry
More informationX8 Option 2 - Technology
moog AC DC AC 4 to 450 A 4 to 210 A Compact MSD Servo Drive TTL in out Specification X8 Option 2 - Technology TTL Encoder Simulation / TTL Master Encoder moog Specification Option 2 - Technology TTL encoder
More informationProduct Information Sheet UH36 Hi Pot Tester
Product Information Sheet UH36 ETL Prüftechnik GmbH Telefon: +49 711 83 99 39-0 E-Mail: info@etl-prueftechnik.de Carl-Peters-Straße 23 D-70825 Korntal-Münchingen Telefax: +49 711 83 99 39-9 Internet: www.etl-prueftechnik.de
More informationD634-P Series Direct Drive Proportional Valve with Integrated 24 V Electronics ISO 4401 Size 05
D634-P Series Direct Drive Proportional Valve with Integrated 24 V Electronics ISO 4401 Size 05 GENERAL SECTION PAGE MOOG SERVO- AND PROPORTIONAL CONTROL VALVES General 2 enefits and Functionality 3 General
More informationMANUAL Device Type Manager
FACTORY AUTOMATION MANUAL Device Type Manager 2D Laser Scanner OBD10M-R2000-4EP-V1V17 With regard to the supply of products, the current issue of the following document is applicable: The General Terms
More informationPNOZmulti Configurator V8.1.1
General 1000 PNOZmulti 1.1 1100 General 1- ][Allgemein Configurator V8.1.1 This document contains important information, which must be noted. This document also contains details of the changes made in
More informationCurrent Monitoring Kit QUICK START GUIDE
Current Monitoring Kit QUICK START GUIDE Pico Technology EL040 Current Monitoring Kit Quick Start Guide CONTENTS 1 Introduction... 1 2 Kit contents... 3 3 Installation... 3 3.1 Connecting the system together...
More informationWahl C50 Calibrator FEATURES
NEW! On Site Multifunction Portable Far Superior Accuracy as Compared to Fluke! Simultaneous Measurement and Generation Quick Connect Terminals Anti-Shock Boot Quick Connect Terminals Navigator Power Supply,
More informationUSB-AD14f Data Acquisition System (USB)
Data Acquisition System (USB) Measurement & Control. Super-Low Priced. Record and output signals with the USB-AD14f. The USB data acquisition system accomodated in a stable aluminum housing is ideal for
More informationHow To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)
transmitter (2 wire) / switch for continuous or On/Off Control Indication, monitoring, transmitting and continuous or On/Off control in one device Output signal 4...20 ma, 2-wire for continuous control
More informationUser's Guide. Integrating Sound Level Datalogger. Model 407780. Introduction
User's Guide 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com Back to the Extech 407780 Product Page Integrating Sound Level Datalogger
More informationBrake module AX5021. Documentation. Please read this document carefully before installing and commissioning the brake module!
Documentation Brake module AX5021 Please read this document carefully before installing and commissioning the brake module! Version : 1.2 : 2012.03.05 Date Article-no. : TDmlAX-5021-0000-0200 Page 2/8
More informationQuick Start Guide 00825-0100-4764, Rev DA March 2014. Rosemount 8714D (Calibration Standard) Magnetic Flowtube Simulator
Quick Start Guide 00825-0100-4764, Rev DA Rosemount 8714D (Calibration Standard) Magnetic Flowtube Simulator Quick Start Guide NOTICE This document provides basic guidelines for the Rosemount 8714D. It
More informationProgrammable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2
Type code Ident no. 1545065 Number of channels 2 Dimensions (W x L x H) 108 x 145 x 77.5 mm CoDeSys-programmable acc. to IEC 61131-3 Cable max. 50 m between interface and read/write head 10/100 Mbps Male
More informationSENSORS. Miniature Sensors - S3Z. Advanced line of miniature Asian style of photoelectric sensors. 40-300 mm background suppression
Advanced line of miniature Asian style of photoelectric sensors 4-3 background suppression.7 m proximity, 15 with narrow beam 4 m polarized retroreflective 3 m LASER through beam Standard 3-wire output
More informationLSM-480 USER MANUAL. A.D.J. SUPPLY EUROPE B.V. Junostraat 2 6468 EW Kerkrade The Netherlands www.americanaudio.eu
LSM-480 USER MANUAL A.D.J. SUPPLY EUROPE B.V. Junostraat 2 6468 EW Kerkrade The Netherlands www.americanaudio.eu 1 2 Table of Contents Table of Contents... 3 1.0 Introduction...4 2.0 Features...5 3.0 Front
More informationwww.kem-kueppers.com info@kem-kueppers.com Certified according to DIN EN ISO 9001 Technical Datasheet KVO Series Vortex Flow Meter
www.kem-kueppers.com Certified according to DIN EN ISO 9001 Technical Datasheet KVO Series Vortex Flow Meter Description The KVO Vortex flow meters utilize two primary sensing elements a vortex shedding
More informationElectromagnetic Flow Meter
Electromagnetic Flow Meter Description The EL 2200 series of electromagnetic sensors represent the state of the art for the accurate measurement for water cycle and process applications. Flow meters are
More informationRS - SPM. Serial parallel translator module
ReSatron GmbH Boisheimer Str. 162 D-41751 Viersen Telefon (+49) 02162-45 06 80 Telefax (+49) 02162-45 03 04 email: info@resatron.de RS - SPM Serial parallel translator module RSSPM000215SPM-021 - Subject
More informationAnalogue Input, 4-fold, MDRC AE/S 4.1, GH Q605 0054 R0001
Analogue Input, -fold, MDRC, GH Q605 005 R0001 The analogue input is a DIN rail mounted device for insertion in the distribution board. It is connected to the EIB via the bus connecting terminal supplied.
More informationContents Installing the ucal Software on your PC/Laptop ucal Programmer Version Connecting the ucal Programmer to your PC/Laptop
Contents Installing the ucal Software on your PC/Laptop 1 ucal Programmer Version 1 Connecting the ucal Programmer to your PC/Laptop 1 Optional USB Adapter Kit (for ucal) 1 Installing the USB Driver for
More informationWEA-Base. User manual for load cell transmitters. UK WEA-Base User manual for load cell transmitters Version 3.2 UK
WEA-Base User manual for load cell transmitters 1 Contents 1. Technical data... 3 2. Assembly... 4 2.1 Power supply... 4 2.2 Load cells... 4 2.3 RS-485... 4 2.4 Relays... 5 2.5 Digital input... 5 2.6 Analogue
More informationUPLC TM USB to Serial Port Driver Installation
UPLC TM USB to Serial Port Driver Installation Installing Virtual COM Port (VCP) Drivers for Windows XP To install VCP drivers for an FT232BM device used in the UPLC TM under Windows XP and XP SP1, follow
More informationNI USB-5681 RF Power Meter Specifications
NI USB-568 RF Power Meter Specifications General This document lists specifications for the NI USB-568 RF power meter. Minimum or maximum specifications are warranted under the following conditions: hour
More informationDG-100 Data Logger User Manual. Version 1.2
DG-100 Data Logger User Manual Version 1.2 DG-100 page 2 Table of Content 1 Introduction and Features... 3 Introduction...3 Features...4 2 Specifications... 5 System specification...5 GPS specification...6
More information1 Synchronising Xsens Systems with Noraxon TeleMyo
1 Synchronising Xsens Systems with Noraxon TeleMyo The steps described below show how to make it possible for Xsens Awinda or Sync Station to send a signal (Awinda / Sync Station is Sync OUT and Noraxon
More informationABB i-bus EIB Logic Module LM/S 1.1
Product Manual ABB i-bus EIB Logic Module LM/S 1.1 Intelligent Installation System Contents page 1 General... 3 1.1 About this manual... 3 1.2 Product and functional overview... 3 2 Device technology...
More informationHow To Control Gimbal
Tarot 2-Axis Brushless Gimbal for Gopro User Manual V1.0 1. Introduction Tarot T-2D gimbal is designed for the Gopro Hero3, which is widely used in film, television productions, advertising aerial photography,
More informationCORONA E / FLYPPER ELECTRONIC METER MULTI-JET
APPLICATION Fully electronic compact water meter with impeller scanning for recording volume. Highly accurate recording of all billing data at medium temperatures up to 90 C. FEATURES 4 Electronic sensor
More informationUSB Smart Power Sensor
Low Power Measurement 50Ω -45 dbm to +10 dbm, 50 to 6000 MHz The Big Deal USB HID device compatible with 32/64 Bit operating systems Includes GUI with measurement applications software, simplifying complex
More informationDSD 70 Dual Channel Hall Effect Speed Sensor for Railway Applications, compliant with EN 50155
DSD 70 Dual Channel Hall Effect Speed Sensor for Railway Applications, compliant with EN 50155 Technical information Version: 07.14 General Function The speed sensors family DSD.70 are suitable for generating
More informationElectrical Safety Tester
Electrical Safety Tester GPT-9000 Series QUICK START GUIDE GW INSTEK PART NO. 82PT-99040MA1 ISO-9001 CERTIFIED MANUFACTURER This manual contains proprietary information, which is protected by copyright.
More informationInstallation Instructions for 9555 USB Driver
Prior to using the data modem features of your 9555 handset; you must first install the VCOMPORT 9555 USB Driver. This driver is compatible with: Windows XP Service Pack 2, Windows 2000 Service Pack 4,
More informationThe GV-I/O Box 8 Ports provides 8 inputs and 8 relay outputs, and supports both DC and AC output voltages.
GV-I/O Box 8 Ports The GV-I/O Box 8 Ports provides 8 inputs and 8 relay outputs, and supports both DC and AC output voltages. Key Features 8 inputs and 8 outputs are provided. Up to 9 pieces of GV-I/O
More informationUSB Smart Power Sensor
50Ω -30 dbm to +20 dbm, 1 MHz to 8000 MHz The Big Deal Low cost USB HID device compatible with 32/64 Bit operating systems Includes Measurement Application GUI (Graphical User Interface) software with
More informationInstruction Manual. T3111 T3111L T3111P T3111Ex
www.cometsystem.cz Instruction Manual T3111 T3111L T3111P T3111Ex Programmable transmitter of temperature, relative humidity and other calculated humidity values with external probe and 4-20 ma outputs
More informationENAiKOON ultrasonic fuel-level sensor
ultrasonic fuel-level sensor Product Summary The ultrasonic fuel-level sensor is the perfect solution for monitoring the fuel level and fuel consumption of trucks, boats, construction equipment, generators,
More information10 Thomas, Irvine, CA 92618 USA Tel: (949) 465-0900 Fax: (949) 465-0905 Toll Free: (800) 23 FUTEK
Table of Contents Software Overview... - 4 - Product Key... - 5 - Model Selection... - 6 - Device Selection... - 7 - Menu... - 8 - File... - 8 - Edit... - 8 - View... - 8 - Format... - 8 - Help... - 9
More informationNEW APC Smart-UPS. Advanced line interactive power protection for servers and network equipment. The world s most popular network and server UPS.
NEW APC Smart-UPS Advanced line interactive power protection for servers and network equipment. > The world s most popular network and server UPS. Award-winning Smart-UPS protects critical data by supplying
More informationOPTIMASS 6000 Technical Datasheet
OPTIMASS 6000 Technical Datasheet Sensor for mass flow The high performance meter for process industries Cryogenic, high temperature and high pressure options Supreme liquid and gas performance with CT
More informationAutomation System TROVIS 6400 TROVIS 6493 Compact Controller
Automation System TROVIS 6400 TROVIS 6493 Compact Controller For panel mounting (front frame 48 x 96 mm/1.89 x 3.78 inch) Application Digital controller to automate industrial and process plants for general
More informationUser s Guide DDS-3X25 USB ARBITRARY FUNCTION GENERATOR
User s Guide DDS-3X25 USB ARBITRARY FUNCTION GENERATOR Content General safety summary...1 Introduction...2 Chapter 1 Getting started...3 System Requirements...4 Installing Hardware...5 Installing Software...8
More informationApplication/Connection Examples
This Quick Start Guide is designed to familiarize the user with the connection and configuration of the DTS-305 DIN rail mounted single / 3 phase power & energy meter with RS-485 or TCP communications.
More informationOperating Manual for the Vetronic Services Sapphire Plus ECG System
Operating Manual for the Vetronic Services Sapphire Plus ECG System This manual contains important information on your Sapphire Plus ECG System. Please keep it in a safe place. - Sapphire Plus ECG Operators
More informationAdding Pneumatic Preset Counter. Type 497. Continuously visible preset Integrated pneumatic reset 3 or 5-digit display Convenient button setting
Adding Pneumatic Preset Counter Type 497 Continuously visible preset Integrated pneumatic reset 3 or 5-digit display Convenient button setting VARIABLE PILOT SIGNAL Using two pneumatic preset counters
More informationUSER MANUAL MODEL 72-7480
PATTERN GENERATOR Introduction Through the use of portable HDMI pattern generator MODEL 72-7480, you are able to use 48 timings and 34 patterns, and operate it continuously for 6~8 hours after the battery
More informationUSB-QUAD08. Eight-channel Quadrature Encoder Input Device. Specifications
Eight-channel Quadrature Encoder Input Device s Document Revision 1.1 May 2012 Copyright 2012 s All specifications are subject to change without notice. Typical for 25 C unless otherwise specified. s in
More informationTubular Analog model resolution: 0,5 mm (SLOW mode), 1 mm (FAST mode) Right angle Repeatibility: 0,7 mm Vdc
Ultrasonic sensors for high precision detection of clear and transparent objects Clear object detection, inspection on transparent or highly reflective film and liquid level measurement Standard M18 tubular
More informationInstalling the IF-NMEASC & SC30 Windows XP Drivers & Software
Installing the IF-NMEASC & SC30 Windows XP Drivers & Software The following document will outline the installation and use of the IF-NMEASC and SC-30 USB drivers and SC-30Tool software in three parts:
More information