1 8.7.4 Impulse-voltage withstand test The impulse-voltage withstand tests shall be made by applying the voltage given in A standard lightning impulse in accordance with IEC shall be used. The parameters are: front time: 1,2 µs ± 30 % time to half value: 50 µs ± 20 % output impedance: 500?± 10 % output energy: 0,5 J ± 10 % The length of each test lead shall not exceed 2 m. The impulse voltage shall be applied to the appropriate points accessible from the outside of the device, the other circuits and the exposed conductive parts being connected to earth. During the test, no input or auxiliary energizing quantity shall be applied to the device. Three positive and three negative impulses shall be applied at intervals of not less than 5 s. Acceptance criteria: no flashover is accepted and after the test, the ECT shall still comply with basic accuracy tests. Summary of Low Voltage Components Voltage Withstand Test: All of NxtPhase Generation 3 electronics have been designed to meet the requirements of this section of the IEC Standard. At this time, no test results are available, as the testing is not completed. Test results will be provided as soon as reports are generated once testing is complete. Original Low Voltage Components Voltage Withstand Test Report: See comment above NxtPhase T&D Corporation Page 21

2 The IEC Standard Requirements 8.8 EMC tests General The tests shall be made to prove the compliance with In many cases an electronic transformer may be divided into a number of major subassemblies such as, for example, circuits located in control cubicles and circuits located in the switchgear area. EMC tests relevant for the applied technology of electronic transformer have to be carried out on each major subassembly the full electronic transformer being in operation or the missing subassemblies being simulated. An example of major subassembly division is given in figure 15. (1) (2) Sub-assembly 1 (2) Sub-assembly 2 (7), (8) (3) (4), (5), (6),(7), (8) (4), (5), (6) Link between Sub-assembly 1 and 2 (3) Switchyard area Control cubicle area (1) HV line (2) Enclosure port (3) Ground port (4) Signal port (5) Command port (6) Communication port (7) a.c. power port (8) d.c. power port Sub-assembly 1 : "outdoor part" in switchgear area Sub-assembly 2 : "indoor part" in control cubicle area Figure 15 Example of subassembly subjected to EMC tests 2005 NxtPhase T&D Corporation Page 22

3 8.8.2 General conditions during EMC tests The general conditions for EMC tests are described in IEC and CISPR 11.uring the EMC tests, the length of cable between the ECT and test equipment and between subassembly 1 and 2 should be the maximum specified by the manufacturer and the arrangement of the cable shall, as far as practicable, represent in-service conditions EMC emission tests An emission test will be performed according to the CISPR 11 testing procedure. The test limits will be those of group 1 class A. The test shall preferably be performed on the complete assembly but for ease of testing in case one of the possible subassemblies contains no electrical parts, that test can be performed on the remaining subassemblies. Summary of EMC Emission Tests: Test Result: Pass Generation 3 Electronics Serial # Prototype Rated Voltage: 69 kv Rated Current: 2000 A Protocol Labs report #: 03056, Date: 4/26/2005 Test date: 1/31/2005 through 2/25/2005 Basic Standards: Conducted Emissions (CISPR 11/22 Class A): Pass [X] Fail [ ] N/A [ ] Radiated Emissions (CISPR 11/22 Class A): Pass [X] Fail [ ] N/A [ ] Conducted Emissions (FCC Part 15/B Class A): Pass [X] Fail [ ] N/A [ ] Radiated Emissions (FCC Part 15/B Class A): Pass [X] Fail [ ] N/A [ ] Conducted Emissions (ICES 003 Class A): Pass [X] Fail [ ] N/A [ ] Radiated Emissions (ICES 003 Class A): Pass [X] Fail [ ] N/A [ ] Conducted Emissions (EN55011/22 Class A): Pass [X] Fail [ ] N/A [ ] Radiated Emissions (EN55011/22 Class A): Pass [X] Fail [ ] N/A [ ] Electrostatic Discharge ( ) Level 4: Pass [X] Fail [ ] N/A [ ] Electrostatic Discharge (IEEE C ) Level 4: Pass [X] Fail [ ] N/A [ ] Electrostatic Discharge (IEC ) Level 4: Pass [X] Fail [ ] N/A [ ] Testing was performed per the following standards, pursuant to IEC :2002 and EN 50263:2000. Radiated and Power Line Conducted Emission tests were performed using measurement procedure CISPR 11. Radiated emissions were performed on an open area 10m test site. Table Emissions Test Results - International Test Standard Description Result Conducted Emissions CISPR 11/22 Class A Limits EN55011/22 Class A Limits The Conducted Emissions are measured on the phase and Neutral Power lines in the MHz range. Pass Radiated Emissions CISPR 11/22 Class A Limits EN55011/22 Class A Limits The radiated emissions are measured in the MHz range. Pass 2005 NxtPhase T&D Corporation Page 23

4 Test Standard Description Result Power Line Harmonics EN Class D Limits Maximum 1.08, 2.3, 0.43, 1.14, 0.3, 0.77, 0.23 A... for 2nd to nth Harmonic N/A DC Powered Power line Fluctuations (Flicker) EN P st <1, P lt < 0.65 Maximum 3% total Harmonic Distortion N/A DC Powered Original EMC Emission Test Report: See Appendix A NXCT Gen 3.0 Project, Current Transducer Systems for Metering and Protection, Applications EMC Compliance Test Report D00559R00.00 The IEC Standard Requirements EMC immunity tests The test shall be performed on a port-by-port basis, guidance for the identification of ports being given in figure Harmonic and interharmonic disturbance test The test shall be performed according to the test procedure of IEC The severity level is class 2 (full harmonic distortion 10 %). The assessment criterion is given in Slow voltage variation test The test shall be performed according to the test procedure of IEC for a.c. power supply and IEC for d.c. power supply. The voltage variations used are from +10 % to 20 % of the nominal voltage of the a.c. power supply and from +20 % to 20 % of the nominal voltage of the d.c. power supply. The assessment criterion is given in Voltage dips and short interruption test The test shall be performed according to the test procedure of IEC for a.c. power supply and IEC for d.c. power supply. The voltage dip used for the test is 30 % of the nominal voltage of the a.c. power supply during 0,02 s. The voltage interruption test is performed during 0,1 s for a.c. power supply. The voltage dip used for the test is 40 % of the nominal voltage of the d.c. power supply during 0,05 s. The voltage interruption test is performed during 0,05 s or 0,02 s for d.c. power supply. The assessment criterion is given in NxtPhase T&D Corporation Page 24

5 Surge immunity test The test shall be performed according to the test procedure of IEC The test generator to be used is the combination wave (hybrid) generator (IEC , 6.1) with standard 1,2/50 s voltage waveform (open-circuit) and 8/20 s current waveform (shortcircuit). The test level is according to installation class 4 (4 kv common mode, 2 kv differential mode). The assessment criterion is given in Electronic fast transient/burst test The test shall be performed according to the test procedure of IEC , the test level being class 4 (4 kv test voltage at 2,5 k Hz repetition rate on power supply port and 2 kv at 5 k Hz repetition rate on input/output signal, data and control ports common mode). The test will be carried out using the coupling/decoupling network on the power supply port and the capacitive coupling clamp on I/O and communication ports. The assessment criterion is given in Oscillatory waves immunity test The test shall be performed according to the test procedure of IEC The test generator to be used is the damped oscillatory wave generator (IEC , 6.1.2). The test voltage will be 2,5 kv common mode and 1 kv differential mode both for power supply and control/signal lines (as in IEC ). Test frequency will be 1 M Hz at 400/s repetition rate (as in IEC ). The assessment criterion is given in Electrostatic discharge test The test shall be performed according to the test procedure of IEC The test level is class 2 (4 kv test voltage), which gives protection in antistatic environments (like concrete) for relative humidity as low as 10 % (see also IEC , clause A.4). The assessment criterion is given in Power-frequency magnetic field immunity test The test shall be performed according to the test procedure of IEC Test level is 5 (100 A/m steady state and A/m??1). The assessment criterion is given in Pulse magnetic field immunity test The test shall be performed according to the test procedure of IEC Test level is 5 ( A/m peak). The assessment criterion is given in Damped oscillatory magnetic field immunity test The test shall be performed according to the test procedure of IEC Test level is class 5 (100 A/m test field). The assessment criterion is given in Radiated, radiofrequency, electromagnetic field immunity test The test shall be performed according to the test procedure of IEC Test level is class 3 (10 V/m field strength). The assessment criterion is given in NxtPhase T&D Corporation Page 25

6 Summary of EMC Immunity Tests: Test Result: Pass Generation 3 Electronics Serial # Prototype Rated Voltage: 69 kv Rated Current: 2000 A Protocol Labs report #: 03056, Date: 4/26/2005 Test date: 1/31/2005 through 2/25/2005 Radiated RF Susceptibility ( ) Level 3: Pass [X] Fail [ ] N/A [ ] Radiated RF Susceptibility (IEC ) Level 3: Pass [X] Fail [ ] N/A [ ] Radiated RF Susceptibility (IEEE C ) 35V/m: Pass [X] Fail [ ] N/A [ ] Radiated RF Susceptibility (IEEE C37.92) 35V/m: Pass [X] Fail [ ] N/A [ ] Electrical Fast Transient/Burst ( ) Level 4: Pass [X] Fail [ ] N/A [ ] Electrical Fast Transient/Burst (IEEE C ) Level 4: Pass [X] Fail [ ] N/A [ ] Electrical Fast Transient/Burst (IEC ) Level 4: Pass [X] Fail [ ] N/A [ ] Surge Immunity ( ) Level 4: Pass [X] Fail [ ] N/A [ ] Surge Immunity (IEC ) Level 4: Pass [X] Fail [ ] N/A [ ] Conducted RF Immunity ( ) Level 3: Pass [X] Fail [ ] N/A [ ] Conducted RF Immunity (IEC ) Level 3: Pass [X] Fail [ ] N/A [ ] Power Frequency Magnetic Field Immunity ( ) Level 5: Pass [X] Fail [ ] N/A [ ] Pulse Magnetic Field Immunity ( ) Level 5: Pass [X] Fail [ ] N/A [ ] Damped Oscillatory Magnetic Field ( ) Level 5: Pass [X] Fail [ ] N/A [ ] Oscillatory Waveforms Immunity ( ) Level 3: Pass [X] Fail [ ] N/A [ ] Oscillatory Waveform Immunity (IEC ) Level 3: Pass [X] Fail [ ] N/A [ ] Surge Withstand Capability, Oscillatory Waveform (IEEE C ) Pass [X] Fail [ ] N/A [ ] Voltage Dips Interruptions & Variations ( ), 200ms Interrupt Pass [X] Fail [ ] N/A [ ] Voltage Dips Interruptions & Variations ( ), 1200ms Interrupt Pass [X] Fail [ ] N/A [ ] Voltage Interruptions (IEC ) 200ms Interrupt Pass [X] Fail [ ] N/A [ ] Tests were conducted on a sample of the equipment for the purpose of demonstrating compliance with the following standards. Testing was performed per the following standards, and the EUT responded as noted NxtPhase T&D Corporation Page 26

7 Table Immunity Test Summary Applicable Standard ESD EN IEC IEEE C Radiated Immunity EN IEC Radiated Immunity IEEE C IEEE C37.92 EFT/Burst EN IEC IEEE C Surge Immunity EN IEC Conducted RF EN IEC Power Frequency Magnetic Field EN Magnetic Pulse EN Damped Oscillatory Magnetic Field EN Oscillatory Immunity EN IEC IEEE C Slow Voltage Variations EN Voltage Interruptions EN IEC Voltage Dips EN Description Air Discharge up to 15 kv and Contact Discharge at 8 kv at several locations with 10 positive and 10 negative discharges per location. Subject to electromagnetic field of 10V/m from 80 MHz to 1000 MHz and 1.4 GHz to 2.0 GHz. Subject to electromagnetic field of 35 V/m from 25 MHz to 1000 MHz EFT/Burst of 4.0 kv is coupled to the all I/O and control signals, respectively and 4.0 kv is injected on the Power Line. 4 kv Positive and Negative Surges are injected in Common Mode, Differential Mode, as well as shielded lines All lines are RF coupled to 10Vrms level from MHz. For magnetically susceptible apparatus only. Subject to a magnetic Field of 100A (RMS) A/m for 60 seconds and 1000 (RMS) A/m for 3 seconds. For magnetically susceptible apparatus only. Subject to magnetic s pulse Field of 1000 A/m is applied Magnetic field-tests for electronic equipment in H.V. sub-stations. Applied on the X, Y and Z-axis. Repetitive, damped oscillatory waves occurring mainly in power, control and cables installed in H.V. and M.H. sub stations. Test or Measurement Air Discharge Contact Discharge Modulated Frequency Field Keyed Direct injection Coupling Clamp Line to Ground Line to Line Applied to the Shield Modulated Frequency Field Applied on all 3 axis Applied on all 3 axis Applied on all 3 axis Common Mode: Differential Mode Required Level +/- 15 kv Criterion (See Pass/Fail Criteria Section) Metering Protection Result +/- 8 kv B A Complies 1 khz 80% AM 10 V/m Keyed 35 V/m +/- 4.0 kv A A Complies A A Complies +/- 4.0 kv B A Complies +/- 4.0 kv +/- 2.0 kv +/- 4.0 kv B A Complies 1 khz 80% AM 10 Vrms 100 A/m for 60 sec 1000 A/m for 3 sec 1000 A/m 100 A/m 2.5 kv 2.5 kv The DC voltage is varied Voltage Varied +/- 20% The voltage on the power supply is interrupted for a set amount of time The voltage and current are varied for a set amount of time Voltage interrupted Voltage Dips Current Dips 100% for up to 200ms 50% for 100ms 60% for 50ms B A Complies A A Complies B A Complies B A Complies B A Complies A A Complies A 50ms A 200m s Complies A A Complies 2005 NxtPhase T&D Corporation Page 27

8 Original EMC Emission Test Report: See Appendix A NXCT Gen 3.0 Project, Current Transducer Systems for Metering and Protection, Applications EMC Compliance Test Report D00559R00.00 The IEC Standard Requirements 8.9 Accuracy test General The following accuracy tests are applied to measuring electronic current transformer and to protective electronic current transformer. Test circuits are given in annex B for digital output and annex C for analogue output. Basic accuracy tests Basic accuracy tests for measuring electronic current transformer To prove compliance with 12.2, tests shall be made at each value of current given in tables 19, 20 and 21 at rated frequency, at rated burden (if relevant), and at ambient temperature, unless otherwise specified. Current transformers having rated primary current factor greater than 1,2 shall be tested at rated primary extended current instead of 1,2 times the rated primary current. NOTE The test can be carried out using a pure delay time device inserted between the reference transformer and the accuracy measurement system Basic accuracy test for protective electronic current transformer To prove compliance with , the test shall be made at rated primary current (see table 22), at rated frequency, at rated burden (if relevant) and at ambient temperature. NOTE The test can be carried out using a pure delay time device inserted between the reference transformer and the accuracy measurement system Temperature cycle accuracy test In addition to the basic accuracy tests made in accordance with 8.9.2, the temperature cycle accuracy test shall be performed in the following conditions:? at rated frequency;?at rated current or rated primary extended current applied continuously;?at rated burden (if relevant);?with indoor and outdoor components exposed to their specific maximum and minimum ambient air temperature. A cycle test in accordance with figure 16 shall be performed NxtPhase T&D Corporation Page 28

9 Figure 16 Temperature cycle accuracy test Minimum temperature variation rate is 5 K/h. It can be higher only if allowed by the manufacturer. The thermal time constant shall be declared by the manufacturer. NOTE Time needed to stabilize the temperature of the electronic current transformer depends mainly on the size and construction of the transformer. For electronic current transformers, partially indoor, partially outdoor, the tests shall be made for indoor and outdoor parts, each one at both extremes of relevant temperature range, respecting the following rules: ambient air temperature for both parts; maximum temperature for indoor part when maximum temperature for outdoor part; minimum temperature for indoor part when minimum temperature for outdoor part. In normal service conditions the measured error of every measuring point should be within the limits of the relevant accuracy class Test for accuracy versus frequency In addition to the basic accuracy tests made in accordance with 8.9.2, tests for accuracy shall be made at the two extremes of standard reference range of frequency given in 5.1.5, at rated current, at rated burden (if relevant) and at constant ambient temperature. The error shall be within the limits of the relevant accuracy class. NOTE Measurement with different frequencies are performed with a test circuit. For the tests, accuracy measurement system calibrated at rated frequency may be acceptable Test for accuracy in relation to replacement of components To prove compliance with clause 0 the following test shall be performed. The ability of the electronic current transformer to fulfill its accuracy class when some of its components are replaced shall be proven by means of an accuracy test at room temperature, rated frequency, rated current and rated burden (if relevant) NxtPhase T&D Corporation Page 29

10 8.9.5 Test for signal-to-noise ratio To prove compliance with a test for signal-to-noise ratio shall be performed. The test procedure shall be agreed upon between manufacturer and user. See D.2.3 for guidance Additional accuracy tests for protective electronic current transformers Test for composite error Tests shall be made at rated primary current to prove compliance with in respect of current error and phase error. Compliance with the limits of composite error given in table 21 shall be demonstrated by a direct test in which a substantially sinusoidal current equal to the rated accuracy limit primary current is passed through the primary terminals with rated burden (if relevant). The test may be carried out on an ECT similar to the one being supplied, except that reduced insulation may be used provided that the same geometrical arrangement is retained. NOTE Where very high primary currents and a single-bar primary conductor of ECT are concerned, the distance between the return primary conductor and the ECT should be taken into account from the point of view of reproducing service conditions Test for transient performance Compliance with the limits of instantaneous error up to t?and/or t and at accuracy limit condition given in table 21 shall be demonstrated by a direct test in which a transient current defined in is passed through the primary terminals with rated burden (if relevant), rated primary short-circuit current, rated primary time constant and rated duty cycle. NOTE Where very high primary currents and a single-bar primary conductor of ECT are concerned, the distance between the return primary conductor and the ECT should be taken into account from the point of view of reproducing service conditions NxtPhase T&D Corporation Page 30

11 Summary of Accuracy Tests: Test Result: Pass, meets 0.2S class CT serial #: D0XXXXR Rated Voltage: 345 kv Rated Current: 2000 A Powertech report #: REP2, Date: 4/25/2003 Test date: 1/23/2003 through 1/27/2003 NXCT accuracy tests, in accordance with IEC (2002), were performed throughout a battery of type tests required by the IEC standard. The NXCT was a metering class CT with 4V and 1A outputs at rated current NxtPhase T&D Corporation Page 31

12 Test Result: Pass, meets 0.2S class CT serial #: D0XXXXR Rated Voltage: 345 kv Rated Current: 2000 A Powertech report #: REP3, Date: 4/25/2003 Test date: 1/23/2003 A linearity test was performed on the NXCT in accordance with IEC (2002). The results are presented in the table below. Linearity Test Results: 2005 NxtPhase T&D Corporation Page 32

13 Test Result: Pass, meets 0.2S class CT serial #: D0XXXXR Rated Voltage: 345 kv Rated Current: 2000 A Powertech report #: REP4, Date: 4/25/2003 Test date: 3/28/2003 A temperature cycle test was performed on the NXCT in accordance with IEC (2002). The results are presented in the charts below. The test current was 1200A NxtPhase T&D Corporation Page 33

14 Test Result: Pass CT serial #: D0XXXXR Rated Voltage: 345 kv Rated Current: 2000 A Powertech report #: REP1, Date: 4/25/2003 Test date: 1/24/2003 A temperature rise test at 3000 A was performed on the NXCT in accordance with IEC (2002) and IEEE C The results are presented in the table below NxtPhase T&D Corporation Page 34

15 Test Result: Pass, class A CT serial #: D00246R Rated Voltage: 420 kv Rated Current: 2000 A NxtPhase Document #: D00341R00.00, Date8/29/2003 Test date: 9/21/2003 A temperature rise test at 4000 A was performed on the NXCT in accordance with IEC (2002) and IEEE C The NXCT was a protection class CT with a 0.2 V output at rated current. The NXCT passed the temperature rise test at 4000 Arms thermal current with a A class of insulation (60 C temperature rise of the bus) for classes not immersed in oil or bituminous compound according to the IEC industry standard. Original Accuracy Test Reports: 2005 NxtPhase T&D Corporation Page 35

16

17

18

19

20 T1-Other Document TEMPERATURE-RISE TEST (4000 A) Doc #: D00341R00.00 Released Status: Preliminary Author: Allen Rose Approver(s): Eric Hadley, Jim Blake 1. Revision History Revision Revision Date: Sections Description of Change: Revised by: Level: (YYYY-MM-DD) Affected: R all First Document Release AHR 2. Introduction This document reports the results of a temperature-rise test performed on a 2 turn protection NXCT on September 21, The test witnesses are Allen Rose, Eric Hadley, and Jim Blake. The NXCT has a serial number of D00246R Scope The test was performed in accordance with sections 5.1.6, 6.1.2, and 8.2 of the IEC industry standard with a 4000 A rms thermal current. The NXCT was fitted with a standard 4.5 round bus and 4 hole NEMA pad connectors. (See photos below.) 4. Results The NXCT #D00246R passed the temperature rise test at 4000 A rms thermal current with a A class of insulation (60 C temperature rise of the bus) for classes not immersed in oil or bituminous compound according to the IEC industry standard. Scale factor error, measured at the rated current of 2000 A, before test was 0.02% ± 0.12% and after test and cool down, 0.13% ± 0.12%. The actual rise of the bus was 47 C above ambient temperature. The phase offset is about -0.7 and remained constant throughout the test. The performance of the sensor before and after the 4000 A heat rise test did not change within the uncertainty of the measurements. 5. Related Standard Document Number IEC Definitions NXCT DVM Term 7. Test Metrology Title Instrument transformers Part 8: electrical current transducers NxtPhase Current Transducer Digital volt meter Definition The NXCT was tested for scale factor accuracy using a Knopp CT-5000 (with a 0.1Ω burden), Arbiter, and Agilent DVM 3458A. A SRS 530 lockin amplifier was used to monitor the scale factor during the test. AD590 temperature probes provided the temperature readings. The accuracy of the AD590s are ±1 C. The accuracy of the combined Knopp and arbiter is 510 ppm for the current reading. The accuracy of the Agilent 3458A in this test arrangement is about 0.10 %. All instruments are NIST traceable. Total uncertainty on the current ratio or scale factor error is about 0.12 %. C:\Documents and Settings\arose\My Documents\power tech\gen 2\Temperature rise test D00341.doc PROPRIETARY INFORMATION. Do Not Disseminate Without The Consent Of NxtPhase Copyright 2003 Last Saved: 9/11/2003 2:34 PM Page 1 of 4

21 8. Test diagram Transformer Isolated Current Source 4000 A Knopp 5000:1 NXCT 2000 A :0.2 V 0.1 Ω Arbiter DVM Lockin Amplifier with difference amp *The lockin difference amplifier should not be connected to the NXCT output when reading the DVM output. The common mode noise on the NXCT output biases the DVM reading by about 20 mv, because the lockin difference amplifier grounds one side of the NXCT differential output. The DVM should have a filter function of 20 to 100 Hz on. 9. Test Photographs C:\Documents and Settings\arose\My Documents\power tech\gen 2\Temperature rise test D00341.doc PROPRIETARY INFORMATION. Do Not Disseminate Without The Consent Of NxtPhase Copyright 2003 Last Saved: 9/11/2003 2:34 PM Page 2 of 4

22 10. Temperature profile of test The slope of the bus bar temperature from 13.5 to 14.5 hours is 0.45 C/h within the IEC standard of 1 C/h. The test was performed in still air. The head shows no steady state temperature rise above the air temperature with the 4000 A heating current. Temperature ( o C) Temperature rise test data Slope 0.45 o C/h Bus Bar Clamp Base Air Head Time (h) C:\Documents and Settings\arose\My Documents\power tech\gen 2\Temperature rise test D00341.doc PROPRIETARY INFORMATION. Do Not Disseminate Without The Consent Of NxtPhase Copyright 2003 Last Saved: 9/11/2003 2:34 PM Page 3 of 4

23 11. NXCT performance during the heat rise test The scale factor error performance during the test shows that the head temperature rose with the heated air around the current source. The scale factor change shown below represents 10 C differential between the base, and the head. Our sensor is known to exhibit a scale factor sensitivity to this difference of about 200 ppm/ C Scale Factor Error (%) Scale factor error Calibration points Bus Bar Head Temperature ( o C) Time (h) 14 C:\Documents and Settings\arose\My Documents\power tech\gen 2\Temperature rise test D00341.doc PROPRIETARY INFORMATION. Do Not Disseminate Without The Consent Of NxtPhase Copyright 2003 Last Saved: 9/11/2003 2:34 PM Page 4 of 4

24 The IEC Standard Requirements 8.11 Verification of the protection Verification of the IP coding In accordance with the requirements specified in and , tests shall be performed in accordance with IEC on the enclosures of all parts of the ECT fully assembled as under service conditions Mechanical impact test In accordance with the requirements specified in , enclosures for indoor installation shall be subjected to an impact test. Three blows are applied to points of the enclosure that are likely to be the weakest points. Devices such as connectors, displays, etc. are excepted. The use of a spring-operated impact test apparatus as defined in IEC is recommended. After the test, the enclosure shall show no breaks and the deformation of the enclosure shall not affect the normal function of the electronic current transformer, and shall not reduce the specified degree of protection. Superficial damage, such as removal of paint, breaking of cooling ribs or similar parts, or depression of small dimension can be ignored. Summary of Verification of the Protection Tests: All of NxtPhase Generation 3 electronics have been designed to meet all of the requirements of this section of the IEC Standard. At this time, no test results are available, as the testing is not completed. Test results will be provided once testing is complete and as soon as reports are generated Original Verification of the Protection Test Report: See comment above. The IEC Standard Requirements 8.12 Tightness tests The purpose of tightness tests is to demonstrate that the absolute leakage rate F does not exceed the specified value of the permissible leakage rate F rel (6.1.11). For gas-filled electronic current transformer, in general, only cumulative leakage measurements allow calculation of leakage rates. For the application of an adequate test method, reference is made to IEC 60694, 6.8 and to IEC For oil-filed electronic current transformer, the tightness test shall be a type test on the electromagnetic unit assembled as for normal service, filled with the liquid specified. A minimum pressure of (0,5 ±0,1) X10 5 Pa above the maximum operating pressure shall be maintained during 8 h inside the e.m.u. The e.m.u. shall be considered to have successfully passed the test if there is no evidence of leakage NxtPhase T&D Corporation Page 36

25 Summary of Tightness Tests: These tests are not applicable to the NXCT equipment, as they use no oil or gas for insulation. The NXCT is built with a solid dielectric composite column insulator. The IEC Standard Requirements 8.13 Vibration tests Vibrations test for secondary parts The secondary converter, the merging unit and secondary power supply are generally comparable to electrical secondary equipment in the substation and shall be tested in accordance with IEC with the secondary parts operating in the normal service condition Vibration test for primary parts The test arrangement shall, as far as reasonably practicable, represent the worst-case service condition in respect of vibration. Vibration levels will vary depending on connection arrangements, insulation type, and for circuit breakers, the actuation principle (spring mechanisms are considered to generate higher vibration levels) Vibration test for primary parts during short-time current This test is performed to determine that the ECT operates correctly in the presence of vibration resulting from busbar vibration caused by short-time current electromagnetic forces. This test can be carried out in conjunction with short-time current test or composite error test. 5 ms after the last opening of the circuit-breaker, the r.m.s. value of the secondary output signal of the ECT at rated frequency calculated over one period, which should theoretically be 0, shall not exceed 3 % of the rated secondary output. To represent the worst-case condition with respect to vibration, the ECT should be connected via a rigid connection to the circuitbreaker Vibration tests for primary parts mechanically coupled to a circuit- breaker General These tests shall also apply to GIS switchgear, medium voltage switchgear and dead tank circuit -breaker mounted ECTs During operation This test is performed to determine that the ECT operates correctly in the presence of vibration resulting from circuit-breaker operation. The circuit -breaker shall be operated through one duty cycle (open-close-open) without current. 5 ms after the last opening of the circuit -breaker, the output signal of the ECT which should theoretically be 0, shall not exceed 10 % of peak value of the rated secondary output. To represent the worst-case condition in respect of vibration, the circuit-breaker should be connected via a flexible conductor NxtPhase T&D Corporation Page 37

26 Vibration endurance test The circuit -breaker shall be operated without primary current times as described in IEC ECT accuracy at rated current shall be measured before and after the test. The ECT error following the test must not differ from that recorded before the test by more than half the limit of error appropriate to its accuracy class. NOTE Vibration levels generated by circuit -breakers have been found to be principally dependant on the actuation principle. A circuit-breaker having a spring mechanism will generally produce higher levels of vibration, thus an ECT test on such a circuit-breaker may be considered valid for other circuit-breakers, subject to agreement between manufacturer and purchaser. Summary of Vibration Tests: Test Result: Pass CT serial #: D0XXXXR Rated Voltage: 345 kv Rated Current: 2000 A Powertech report #: , Date: 8/27/2003 Test date: 1/22/2003 The NXCT was subjected to horizontal and vertical acceleration. A summary of the Powertech test report is given below. Vibration conditions were as follows: Sine sweep 5 to 500 Hz in horizontal and vertical directions Sweep cycle is 1 octave/min. Amplitude gs peak Test duration one sweep (6 minutes 38 seconds) Sensor output measurements were taken at 5, 10, 30, 50, 60, 70, 120 and the dominant frequency for the orientation being tested. The maximum vertical resonance was at Hz and the maximum horizontal resonance was at Hz. Original Vibration Test Report: 2005 NxtPhase T&D Corporation Page 38

27

28

29

30

Rated Power(W) 8W 2. EG-LED0840-01 8W 3. EG-LED1027-01 10W

Rated Power(W) 8W 2. EG-LED0840-01 8W 3. EG-LED1027-01 10W 14713221 001 Seite 2 von 37 Page 2 of 37 Model List: No Model Rated Voltage(V) 1. EG-LED0827-01 Rated Power(W) 8W 2. EG-LED0840-01 8W 3. EG-LED1027-01 10W 4. EG-LED1040-01 AC 100-240V, 10W 5. EG-LED1027-02

More information

TEST REPORT EN 55014-2 (1997) +A1 (2001)

TEST REPORT EN 55014-2 (1997) +A1 (2001) Page 1 of 23 TEST REPORT EN 55014-2 (1997) +A1 (2001) Electromagnetic compatibility - Requirements for household appliances, electric tools and similar apparatus Part 2: Immunity Report Reference No....

More information

NMI M 6-2 Electricity Meters. Part 2: Test Report Format

NMI M 6-2 Electricity Meters. Part 2: Test Report Format NMI M 6-2 Electricity Meters Part 2: Test Report Format Commonwealth of Australia 2010 First edition September 2010 National Measurement Institute Bradfield Road, Lindfield, NSW 2070 PO Box 264, Lindfield,

More information

Test Report. Prepared for: Technologic Systems, Inc. Model: TS-8820

Test Report. Prepared for: Technologic Systems, Inc. Model: TS-8820 Test Report Prepared for: Technologic Systems, Inc. Model: TS-8820 Description: Single Board Computer with Analog and Digital Inputs and Outputs, Relays, and RS-232/485 Ports To IEC 61000-6-1 (2005-03)

More information

(PREVIEW) Indian Standard COMMON SPECIFICATION FOR HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR STANDARDS

(PREVIEW) Indian Standard COMMON SPECIFICATION FOR HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR STANDARDS (PREVIEW) Indian Standard COMMON SPECIFICATION FOR HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR STANDARDS IS 12729:2004 IEC 60694(2002) 1.1 Scope This International Standard applies to a.c. switchgear and controlgear,

More information

TRACTION NETWORK MONITORING AND PROTECTION SYSTEM SMTN-3 CITY ELECTRIC TRANSPORT RAILWAYS METRO INDUSTRY

TRACTION NETWORK MONITORING AND PROTECTION SYSTEM SMTN-3 CITY ELECTRIC TRANSPORT RAILWAYS METRO INDUSTRY TRACTION NETWORK MONITORING AND PROTECTION SYSTEM SMTN-3 CITY ELECTRIC TRANSPORT RAILWAYS METRO INDUSTRY 2 TRACTION NETWORK MONITORING AND PROTECTION SYSTEM Traction network monitoring and protection system,

More information

AN96-07. Surging Ideas TVS Diode Application Note PROTECTION PRODUCTS. TRANSIENT IMMUNITY STANDARDS: IEC 61000-4-x

AN96-07. Surging Ideas TVS Diode Application Note PROTECTION PRODUCTS. TRANSIENT IMMUNITY STANDARDS: IEC 61000-4-x TRANSIENT IMMUNITY STANDARDS: IEC 61000-4-x On January 1, 1996, exports into Europe began facing some tough transient immunity standards. The International Electrotechnical Commission (IEC), a worldwide

More information

STRATO LED Drivers 70W, Single output

STRATO LED Drivers 70W, Single output Features STRATO switch mode driver technology is designed to generate one constant current output from a wide range AC input. The size and performance of these products make them the ideal choice for LED

More information

Test Report #: 1981-3 Date: April 8, 2005

Test Report #: 1981-3 Date: April 8, 2005 Test Report #: 1981-3 Date: April 8, 2005 CERTIFICATE #2316.01 Issued To: Bill Burks American Power Conversion 85 Rangeway Road North Billerica, MA 01862 USA 978-670-2440 Product Name/Description Model

More information

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description Photoelectrics, Background Suppression reflective with IR light Main features Description The PD30ET... stainless steel sensors are built with high-quality materials and designed for harsh environments.

More information

Waveguide Access Point WGA631. Product Guide

Waveguide Access Point WGA631. Product Guide Waveguide Access Point Product Guide Waveguide Access Point Contents 1. Description............................ 3 2. Application............................ 3 3. Technical data... 4 4. Physical interfaces......................

More information

Voltage Regulator SPAU 341 C. Product Guide

Voltage Regulator SPAU 341 C. Product Guide Issued: July 1998 Status: Updated Version: D/25.04.2006 Data subject to change without notice Features Comprehensive voltage regulation for power transformers with on-load tapchangers in distribution substations

More information

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC - 0.5 A - M8 connector

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC - 0.5 A - M8 connector Product datasheet Characteristics TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC - 0.5 A - M8 connector Main Range of product Product or component type Range compatibility Enclosure material Bus

More information

Analog signal converters CC-E I/I Current / current isolators

Analog signal converters CC-E I/I Current / current isolators ata sheet Analog signal converters CC-E I/I Current / current isolators The CC-E I/I is an isolator for the electrical isolation of current signals without auxiliary supply. It allows the isolation between

More information

DS 600. A contact free flux gate based current measurement sensor 600A rms

DS 600. A contact free flux gate based current measurement sensor 600A rms DS 600 A contact free flux gate based current measurement sensor 600A rms DS 600 is member of the small housing sensor family. The family includes a 200A and a 600A version. 600A rms - 900A peak Maximum

More information

EMC Test for Compliance with EU EMC Directive 2004/108/EU

EMC Test for Compliance with EU EMC Directive 2004/108/EU EMC Test for Compliance with EU EMC Directive 2004/108/EU Partial Test 12-12-2012 Standards Description EN 55022:2011 Information technology equipment - Radio disturbance characteristics - Limits and methods

More information

Experience with taximeters with a look at the corresponding tables

Experience with taximeters with a look at the corresponding tables Experience with taximeters with a look at the corresponding tables Milan Prasil CMI Laboratory of the fundamental metrology V Botanice 4, 150 72 Prague 5 mprasil@cmi.cz Taximeters in EU are subject to

More information

Prepared for Dorman Long Engineering Technology Consultant (Shanghai) Co., Ltd.

Prepared for Dorman Long Engineering Technology Consultant (Shanghai) Co., Ltd. www.ecmg-global.com EMC TEST REPORT On Model Name: DL-P40 Computer Control System Model Number: Release 3.0 Hardware and Software Brand Name: Dorman Long Technology Ltd. Trade Mark: DLT Prepared for Dorman

More information

SUGGESTED SPECIFICATION for Series 185 Service Entrance Rated Automatic Transfer Switches

SUGGESTED SPECIFICATION for Series 185 Service Entrance Rated Automatic Transfer Switches SUGGESTED SPECIFICATION for Series 185 Service Entrance Rated Automatic Transfer Switches PART 1 GENERAL 1.01 Scope Optional Standby Power Generator Systems A. Furnish and install automatic transfer switches

More information

Dual Chamber Temporary External Pacemaker

Dual Chamber Temporary External Pacemaker 5392 Dual Chamber Temporary External Pacemaker Electromagnetic Compatibility Declaration Caution: Federal law (USA) restricts this device to sale by or on the order of a physician. The following list includes

More information

LAB 1 TECHNICAL DOC 3 IN ONE LAB DEVICE. Velleman Legen Heirweg 33 9890 Gavere Belgium

LAB 1 TECHNICAL DOC 3 IN ONE LAB DEVICE. Velleman Legen Heirweg 33 9890 Gavere Belgium LAB 1 TECHNICAL DOC 3 IN ONE LAB DEVICE Velleman Legen Heirweg 33 9890 Gavere Belgium SPECIFICATIONS DIGITAL MULTIMETER 3 1/2 backlit LCD Automatic polarity indication DC voltage 200mV to 600V in 5 steps

More information

1587/1577. Insulation Multimeters. Technical Data. Two powerful tools in one.

1587/1577. Insulation Multimeters. Technical Data. Two powerful tools in one. 1587/1577 Insulation Multimeters Technical Data Two powerful tools in one. The Fluke 1587 and 1577 Insulation Multimeters combine a digital insulation tester with a full-featured, true-rms digital multimeter

More information

Power Meter Series 700

Power Meter Series 700 PowerLogic power-monitoring units Power Meter Series 700 Technical data sheet 2007 Functions and characteristics E90463 The PowerLogic Power Meter Series 700 offers all the measurement capabilities required

More information

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact Data sheet Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact The CT-AHD.12 is an electronic time relay with OFF-delay. It is from the CT-D range. With their MDRC profile and a width of only

More information

7.5 Watt AC-DC Switch Power Supply

7.5 Watt AC-DC Switch Power Supply MAIN FEATURES: 7.5W Small Compact Size PCB Mount Single Output Regulated Output Range : 3.3VDC 24VDC Input Range : 85VAC 265VAC/47 63Hz Or 120VDC 370VDC Very Low Standby Power Consumption < 0.15W Better

More information

EN 301 489-17 v1.2.1 TEST REPORT FOR. 802.11ag/Draft 802.11n WLAN PCI-E Mini Card MODEL NUMBER: BCM94322MC REPORT NUMBER: 07U11529-5

EN 301 489-17 v1.2.1 TEST REPORT FOR. 802.11ag/Draft 802.11n WLAN PCI-E Mini Card MODEL NUMBER: BCM94322MC REPORT NUMBER: 07U11529-5 EN 301 489-17 v1.2.1 TEST REPORT FOR 802.11ag/Draft 802.11n WLAN PCI-E Mini Card MODEL NUMBER: BCM94322MC REPORT NUMBER: 07U11529-5 ISSUE DATE: JANUARY 29, 2008 Prepared for BROADCOM CORPORATION 190 MATHILDA

More information

Power Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1

Power Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1 Power Supply Unit, Primary Switched, Narrow Design MINI POWER provides: Extra narrow design with widths of 22.5 mm, 45 mm, and 67.5 mm (0.886, 1.772, and 2.657 in.) Global use due to a wide-range input

More information

Standard: EN 61000-4-2 :1995, EN 61000-4-3 :1996, ENV 50204 :1993, & EN 61000-4-4 :1995 Solid State Energy Meter

Standard: EN 61000-4-2 :1995, EN 61000-4-3 :1996, ENV 50204 :1993, & EN 61000-4-4 :1995 Solid State Energy Meter Standard: EN 61000-4-2 :1995, EN 61000-4-3 :1996, ENV 50204 :1993, & EN 61000-4-4 :1995 Model: Solid State Energy Meter Prepared for: Analog Devices, Inc. 804 Woburn Street Wilmington, MA 01887 Date of

More information

CAT ATC POWER BREAKER & POWER CASE SWITCH AUTOMATIC TRANSFER SWITCH

CAT ATC POWER BREAKER & POWER CASE SWITCH AUTOMATIC TRANSFER SWITCH CAT ATC POWER BREAKER & POWER CASE SWITCH AUTOMATIC TRANSFER SWITCH Cat transfer switches are designed for a variety of standby power applications. They provide flexibility, reliability and value in a

More information

SHENZHEN GEMBIRD ELECTRONICS LTD EMC REPORT

SHENZHEN GEMBIRD ELECTRONICS LTD EMC REPORT Shenzhen BST Technology Co., Ltd. SHENZHEN GEMBIRD ELECTRONICS LTD EMC REPORT Prepared For : Product Name: Model : Prepared By : SHENZHEN GEMBIRD ELECTRONICS LTD 5th Floor, Building B, Shifeng Industry

More information

Type: EASY719 DC RC Article No.: 274119. Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

Type: EASY719 DC RC Article No.: 274119. Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description Type: EASY719 DC RC Article.: 274119 Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC Description 12 digital inputs (4 inputs available as analog inputs) 6 relay outputs LCD display

More information

DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters Testing all relay technologies: electromechanical, solid state, numerical and IEC61850 Manual

More information

Harmonics and Noise in Photovoltaic (PV) Inverter and the Mitigation Strategies

Harmonics and Noise in Photovoltaic (PV) Inverter and the Mitigation Strategies Soonwook Hong, Ph. D. Michael Zuercher Martinson Harmonics and Noise in Photovoltaic (PV) Inverter and the Mitigation Strategies 1. Introduction PV inverters use semiconductor devices to transform the

More information

TEST REPORT Rapporto di prova EMC N 060406. Test facility site: via L. da Vinci, 92, Caravaggio (BG), Italy Sede laboratorio

TEST REPORT Rapporto di prova EMC N 060406. Test facility site: via L. da Vinci, 92, Caravaggio (BG), Italy Sede laboratorio TEST REPORT Rapporto di prova EMC N 060406 EUT: Organic Carbon Analyzer Analiuzzatore Carbonio Organico Model: TOCMETER Serial N : TM602 Client: TRE-ESSE s.r.l. Cliente Piazzale Europa 8 16036 Recco (GE),

More information

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER Application : The RISH CON - Hz transducer is used for frequency measurement. The output signal is proportional to measured frequency and is either load independent DC Current or load independent DC Voltage.

More information

Chrome DIN Rail Power Supply 12V 54W 1 Phase (Class II & NEC Class 2) / DRC-12V60W1AG

Chrome DIN Rail Power Supply 12V 54W 1 Phase (Class II & NEC Class 2) / DRC-12V60W1AG Highlights & Features Protection Class II, Double Isolation (No Earth connection is required) Universal AC input voltage and full power up to 55 C Power will not de-rate for the entire input voltage range

More information

Electromagnetic Compatibility Test Report Test results of Floww equipment

Electromagnetic Compatibility Test Report Test results of Floww equipment Electromagnetic Compatibility Test Report Test results of Floww equipment Reference number Status test report Brand Model number : 10C00357RPT01.doc : Final : Floww : mobilefloww screenfloww pocketfloww

More information

IEC 1000-4-2 ESD Immunity and Transient Current Capability for the SP72X Series Protection Arrays

IEC 1000-4-2 ESD Immunity and Transient Current Capability for the SP72X Series Protection Arrays IEC 00-4-2 ESD Immunity and Transient Current Capability for the SP72X Series Protection Arrays Application Note July 1999 AN9612.2 Author: Wayne Austin The SP720, SP721, SP723, and SP724 are protection

More information

38 SERIES. Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A. EMR Electromechanical Relays. Common features. SSR Solid State Relays. 6.

38 SERIES. Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A. EMR Electromechanical Relays. Common features. SSR Solid State Relays. 6. 38 Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A 38 Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit 6.2 mm wide EMR - DC, AC or AC/DC

More information

FCC PART 15B CLASS A MEASUREMENT AND TEST REPORT

FCC PART 15B CLASS A MEASUREMENT AND TEST REPORT FCC PART 15B CLASS A MEASUREMENT AND TEST REPORT For SAMBO HI TECH CO., LTD. 616-15, GANSUK4-DONG, NAMDONG-GU, INCHUN 405-810, KOREA Model: LSR700, SCI545HV1EF, SCI545HVEF This Report Concerns: Original

More information

DATA SHEET DVI - HDCP Extension Cable

DATA SHEET DVI - HDCP Extension Cable DATA SHEET DVI - HDCP Extension Cable Contents Description Features Absolute Maximum Ratings Recommended Operating Conditions Electrical Power Supply Characteristics Receiver Electrical Interface Specifications

More information

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features: Application : RISH Master 3490 DS measures important electrical parameters of Utility (in normal mode) & Generators (in Power back up) in three phase and single phase Network & replaces the multiple analog

More information

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit. Current Transducer HO-P series I PN = 6, 10, 25 A Ref: HO 6-P, HO 10-P, HO 25-P For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary

More information

EMC TEST REPORT For. Shenzhen Homelux Security Equipment Co., Ltd. Auto Dialer. Model No.: HX-GD20

EMC TEST REPORT For. Shenzhen Homelux Security Equipment Co., Ltd. Auto Dialer. Model No.: HX-GD20 EMC TEST REPORT For Shenzhen Homelux Security Equipment Co., Ltd Auto Dialer Model No.: HX-GD20 Prepared for : Shenzhen Homelux Security Equipment Co., Ltd Address : 4 th Floor, Building 5, Jiademaluan

More information

Circulating Current Relay. Type IRXm

Circulating Current Relay. Type IRXm Circulating Current Relay Type IRXm ABB a global technology leader ABB is a global leader in Power and Automation technologies that enable utility and industry customers to improve performance while lowering

More information

Energy Management Energy Meter Type EM23 DIN

Energy Management Energy Meter Type EM23 DIN Energy Management Energy Meter Type EM23 DIN Class 1 (kwh) according to EN62053-21 Class B (kwh) according to EN50470-3 Class 2 (kvarh) according to EN62053-23 Accuracy ±0.5 RDG (current/voltage) Energy

More information

NMI R 118 Testing Procedures and Test Report Format for Pattern Evaluation of Fuel Dispensers for Motor Vehicles (OIML R 118:1995(E), NEQ)

NMI R 118 Testing Procedures and Test Report Format for Pattern Evaluation of Fuel Dispensers for Motor Vehicles (OIML R 118:1995(E), NEQ) Testing Procedures and Test Report Format for Pattern Evaluation of Fuel Dispensers for Motor Vehicles (OIM R 118:1995(E), NEQ) The English version of international standard OIM R 118:1995 Testing Procedures

More information

ENGINEERING COMMITTEE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE 46 2007. Test Method for AC to DC Power Supplies

ENGINEERING COMMITTEE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE 46 2007. Test Method for AC to DC Power Supplies ENGINEERING COMMITTEE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE 46 2007 Test Method for AC to DC Power Supplies NOTICE The Society of Cable Telecommunications Engineers (SCTE)

More information

3.1.1 Full Type Tests & Routine Tests according to Clause 8 2 & 8 3. 4.0 Instructions For Installation, Operation & Maintenance

3.1.1 Full Type Tests & Routine Tests according to Clause 8 2 & 8 3. 4.0 Instructions For Installation, Operation & Maintenance SPECIFICATION FOR LOW VOLTAGE SWITCHBOARD SEN I N D E X Description 10 STANDARD TECHNICAL REQUIREMENTS 11 Standards 12 General Operating Conditions 13 General Description Of Switchboard 131 Structure 132

More information

MCR-VDC-UI-B-DC. Voltage Transducer for DC Voltages. INTERFACE Data Sheet 100260_en_01. 1 Description

MCR-VDC-UI-B-DC. Voltage Transducer for DC Voltages. INTERFACE Data Sheet 100260_en_01. 1 Description Voltage Transducer for DC Voltages TERFACE Data Sheet 000_en_0 PHOENIX CONTACT - /00 Description The MCR voltage transducer measures DC voltages in several signal ranges from 0... ±0 V DC to 0... ±0 V

More information

Power-monitoring unit PowerLogic System. Technical data sheet. Power Meter Series 800

Power-monitoring unit PowerLogic System. Technical data sheet. Power Meter Series 800 Power-monitoring unit PowerLogic System Technical data sheet 2003 Power Meter Series 800 Function and characteristics PB100313 The PowerLogic Power Meter Series 800 offers all the high-performance measurement

More information

ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application.

ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application. 1SR 430 824 F9300 Features Monitoring of three-phase mains for phase sequence and failure Powered by the measuring circuit 2 c/o (SPDT) contacts 1 LED for status indication Approvals R: yellow LED - relay

More information

TYPE TEST CERTIFICATE OF SHORT-CIRCUIT PERFORMANCE. A three-phase outdoor oil-immersed distribution transformer

TYPE TEST CERTIFICATE OF SHORT-CIRCUIT PERFORMANCE. A three-phase outdoor oil-immersed distribution transformer 168-08 TYPE TEST CERTIFICATE OF SHORT-CIRCUIT PERFORMANCE APPARATUS A three-phase outdoor oil-immersed distribution transformer DESIGNATION 1000 kva SERIAL No. 1-08-112-01-0001 Rated power Rated voltage

More information

Chrome DIN Rail Power Supply 24V 30W 1 Phase (Class II & NEC Class 2) / DRC-24V30W1AZ

Chrome DIN Rail Power Supply 24V 30W 1 Phase (Class II & NEC Class 2) / DRC-24V30W1AZ Highlights & Features Protection Class II, Double Isolation (No Earth connection is required) Universal AC input voltage without power de-rating Efficiency > 87.0% @ 115Vac & 230Vac NEC Class 2 / Limited

More information

T 3000. Substation Maintenance and Commissioning Test Equipment

T 3000. Substation Maintenance and Commissioning Test Equipment T 3000 Substation Maintenance and Commissioning Test Equipment Multi function system for testing substation equipment such as: current, voltage and power transformers, all type of protection relays, energy

More information

Telephone- and leased line modem for industrial applications TD-36

Telephone- and leased line modem for industrial applications TD-36 Telephone- and leased line modem for industrial applications TD-36 Modem for industrial PSTN- and leased line applications The TD-36 is an analogue V.34 PSTN modem as well as an industrial 2-wire leased

More information

Series AMEPR30-AZ up to 2.5A AC-DC / DC-DC LED Driver / Converter

Series AMEPR30-AZ up to 2.5A AC-DC / DC-DC LED Driver / Converter FEATURES: Click on Series name for product info on aimtec.com Models Single output Model Max Output Power (W) 1 AC-DC Constant Current or Constant Over temperature protection Voltage LED Driver Over current

More information

Arc Terminator Active Arc-Resistant Switchgear

Arc Terminator Active Arc-Resistant Switchgear Arc Terminator Active Arc-Resistant Switchgear Increasing safety and productivity by extinguishing internal arcing faults within the switchgear. The Square D Arc Terminator from Schneider Electric offers

More information

Rack mounted telephone- and leased line modem for industrial applications

Rack mounted telephone- and leased line modem for industrial applications Rack mounted telephone- and leased line modem for industrial applications TR-6 Rack modem for industrial PSTNand /-wire leased line applications The TR-6 is an analogue V. 9 -rack PSTN modem as well as

More information

PRODUCT DATA SHEET AUDIO LINE COMBINATION ALC0300-1300

PRODUCT DATA SHEET AUDIO LINE COMBINATION ALC0300-1300 PRODUCT DATA SHEET AUDIO LINE COMBINATION ALC0300-1300 SCOPE These technical specifications describes the functionalities and features of the Anaview Audio Line Combination ALC0300-1300, an integrated

More information

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection) Data sheet Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection) The temperature monitoring relays CM-TCS monitor overtemperature,

More information

Clamp Filters that Suppress Emission Noise Provide Immunity Against Surge Noise

Clamp Filters that Suppress Emission Noise Provide Immunity Against Surge Noise TDK EMC Technology Product Section Clamp Filters that Suppress Emission Noise Provide Immunity Against Surge Noise TDK Shonai Corporation Satoru Saito Reduce Emission Noise from Cables Even if an electronic

More information

DUAL%CHANNEL BROADBAND%LINEAR%AMPLIFIER Model&A800D

DUAL%CHANNEL BROADBAND%LINEAR%AMPLIFIER Model&A800D ELECTRONICS AB DUAL%CHANNEL BROADBAND%LINEAR%AMPLIFIER Model&A800D & HIGH&VOLTAGE& FIXED&GAIN& BROADBAND & 800Vpp&60mA& 100x& DC&to&ca&200&kHz & LOW&OUTPUT&IMPEDANCE& HIGH&SLEW&RATE &

More information

ANSI Watthour Meter Testing & Certification Programs

ANSI Watthour Meter Testing & Certification Programs ANSI Watthour Meter Testing & Certification Programs By Jim Reed Manager, Meter Accuracy Lab and Manasi Bhandiwad Manager, EMC Lab Laboratories, Inc. First in Certification Accreditations and Recognitions

More information

Bulletin 150 SMC Flex Smart Motor Controller Specifications

Bulletin 150 SMC Flex Smart Motor Controller Specifications Specifications Specifications Standard Features Optional Features Installation Setup Communications Power Wiring Control Wiring Keypad Software Starting and Stopping Modes Protection and Diagnostics Metering

More information

Power Quality Issues, Impacts, and Mitigation for Industrial Customers

Power Quality Issues, Impacts, and Mitigation for Industrial Customers Power Quality Issues, Impacts, and Mitigation for Industrial Customers By Kevin Olikara, Power and Energy Management Products Rockwell Automation, Inc. Now, more than ever, electronic equipment and computing

More information

FREJA 300 Relay Testing System

FREJA 300 Relay Testing System Relay Testing System A Megger Group Company FREJA 300 Relay testing system The FREJA 300 relay testing system is a computer-aided relay testing and simulation system. The weight of FREJA 300 is only 15

More information

80 Series - Modular timers 16 A. Features 80.01 80.11

80 Series - Modular timers 16 A. Features 80.01 80.11 80 Series - Modular timers 16 A Features 80.11 Multi-function and mono-function timer range - Multi-function & multi-voltage 80.11 - On-delay, multi-voltage 17.5 mm wide Six time scales from 0.1s to 24h

More information

MasterINTERFACE 39 Series - Relay interface modules

MasterINTERFACE 39 Series - Relay interface modules MasterINTERFACE 39 Series - Relay interface modules Common features Space saving 6.2 mm wide Connections for 16-way jumper link Integral coil indication and protection circuit Secure retention and easy

More information

Chrome DIN Rail Power Supply 24V 91.2W 1 Phase (Class II & NEC Class 2) / DRC-24V100W1AZ

Chrome DIN Rail Power Supply 24V 91.2W 1 Phase (Class II & NEC Class 2) / DRC-24V100W1AZ Highlights & Features Protection Class II, Double Isolation (No Earth connection is required) Universal AC input voltage without power de-rating Efficiency > 87.0% @ 115Vac, > 89.0% @ 230Vac NEC Class

More information

Relion 605 series. Self-powered feeder protection REJ603 Product Guide

Relion 605 series. Self-powered feeder protection REJ603 Product Guide Relion 605 series Relion 605 series Relion 605 series Self-powered feeder protection Product Guide Product version: 3.0 Contents 1.... 3 2. Relay functions... 3 3. Protection functions... 4 4. Application...

More information

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs E031026 000823 Process modules Digital input PMI for inputs for 120 V AC inputs PMI Input E4, E5, GND L- PMI 120 V AC Input E4, E5, Common C E6, E7, GND L- E6, E7, Common C LEDs for the inputs operation

More information

H/L = Power supply. FN = Nominal Frequency. RN = Rated value of output burden. UN = Nominal input voltage. IN = Nominal input current.

H/L = Power supply. FN = Nominal Frequency. RN = Rated value of output burden. UN = Nominal input voltage. IN = Nominal input current. Application : The transducer RISH CON - CA/CV (Fig.1) converts a sinusoidal AC Current or AC Voltage into a load independent DC Current or a load independent DC Voltage proportional to the measured value.

More information

Module 11: Conducted Emissions

Module 11: Conducted Emissions Module 11: Conducted Emissions 11.1 Overview The term conducted emissions refers to the mechanism that enables electromagnetic energy to be created in an electronic device and coupled to its AC power cord.

More information

ABB 1 NEW. Three-phase monitoring relay for grid feeding CM-UFS.1. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories

ABB 1 NEW. Three-phase monitoring relay for grid feeding CM-UFS.1. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories 2CDC 251 014 F0t09 Features Monitoring of three-phase mains for grid feeding Type-tested in accordance with DIN V VDE V 0126-1-1: February 2006 Neutral conductor connection configurable Can also be used

More information

NI USB-5681 RF Power Meter Specifications

NI USB-5681 RF Power Meter Specifications NI USB-568 RF Power Meter Specifications General This document lists specifications for the NI USB-568 RF power meter. Minimum or maximum specifications are warranted under the following conditions: hour

More information

Power Supply, Primary Switch Mode, Narrow Design MINI-PS-100-240AC/2x15DC/1

Power Supply, Primary Switch Mode, Narrow Design MINI-PS-100-240AC/2x15DC/1 Power Supply, Primary Switch Mode, Narrow Design -PS-100-240AC/2x15DC/1 POWER provides: Extra narrow widths of 22.5 and 45 mm (0.886 and 1.772 in.) Global use due to a wide range input A high level of

More information

Cable Solutions for Servo and Variable Frequency Drives (VFD)

Cable Solutions for Servo and Variable Frequency Drives (VFD) Cable Solutions for Servo and Variable Frequency Drives (VFD) Electric drive systems with continuous torque and speed control are widespread today. They allow an optimal adjustment of the drive with respect

More information

Single-phase (220...240 V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable

Single-phase (220...240 V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable Features 70.11 70.31 70.41 Electronic voltage monitoring relays for single and three-phase applications Multifunctional types, providing the flexibility of monitoring Undervoltage, Overvoltage, Window

More information

www.siemens.com/energy High Voltage Circuit Breakers 3AP Type 72.5 kv to 800 kv Answers for energy.

www.siemens.com/energy High Voltage Circuit Breakers 3AP Type 72.5 kv to 800 kv Answers for energy. s www.siemens.com/energy High Voltage Circuit Breakers AP Type 7.5 kv to 800 kv Answers for energy. The AP High Voltage Circuit Breakers Available up to 800 kv Decades of our experience in high voltage

More information

38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 A

38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 A 38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 A Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit EMR Electromechanical Relays

More information

Circuit Breaker LTB D with Motor Drive. Motor Drive. ABB PP/H/HV - Page 1. Ed 2006-04

Circuit Breaker LTB D with Motor Drive. Motor Drive. ABB PP/H/HV - Page 1. Ed 2006-04 Circuit Breaker LTB D with Motor Drive Motor Drive ABB PP/H/HV - Page 1 Ed 2006-04 Technology Traditional technology Traditional spring operating mechanism: Closing mechanism ABB PP/H/HV - Page 2 Tripping

More information

Isolated AC Sine Wave Input 3B42 / 3B43 / 3B44 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Isolated AC Sine Wave Input 3B42 / 3B43 / 3B44 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM Isolated AC Sine Wave Input 3B42 / 3B43 / 3B44 FEATURES AC averaging technique used to rectify, amplify, and filter 50 Hz to 400 Hz sine-wave signals. Accepts inputs of between 20 mv to 550 V rms to give

More information

SINEAX U553 Transducer for AC Voltage

SINEAX U553 Transducer for AC Voltage With power supply RMS value measurement Carrying rail housing P/0 Application he transducer SINEAX U55 (Fig. ) converts a sinusoidal or a distorted AC voltage into a load independent DC current or a load

More information

APC Matrix-UPS 5kVA 208V/240V In 120/208/240V Out

APC Matrix-UPS 5kVA 208V/240V In 120/208/240V Out APC Matrix-UPS 5kVA 208V/240V In 120/208/240V Out APC Matrix-UPS, 3750 Watts / 5000 VA,Input 208V / Output 120V, 208V, Interface Port DB-9 RS-232, SmartSlot, Extended runtime model Includes: CD with software,

More information

Thermistor motor protection relays CM-MSS.22 and CM-MSS.23

Thermistor motor protection relays CM-MSS.22 and CM-MSS.23 Data sheet Thermistor motor protection relays CM-MSS.22 and CM-MSS.23 The thermistor motor protection relays CM-MSS.22 and CM-MSS.23 monitor the winding temperature of motors and protect them from overheating,

More information

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD INTERNATIONAL STANDARD IEC 61131-2 Second edition 2003-02 Programmable controllers Part 2: Equipment requirements and tests Automates programmables Partie 2: Spécifications et essais des équipements IEC

More information

Specification guide no. 9 Active harmonic conditioner from 20 to 480 A

Specification guide no. 9 Active harmonic conditioner from 20 to 480 A Active harmonic conditioner from 20 to 480 A Contents 1 - Installations concerned... 2 1.1 - New installations... 2 1.2 - Existing installations... 2 2 - General... 2 2.1 - Scope... 2 2.2 - Applicable

More information

MasterINTERFACE 39 Series - Relay interface modules

MasterINTERFACE 39 Series - Relay interface modules MasterINTERFACE 39 Series - 39 Common features Space saving 6.2 mm wide Connections for 16-way jumper link Integral coil indication and protection circuit Secure retention and easy ejection by plastic

More information

Table of Contents. TransformerIQ FAQs 1

Table of Contents. TransformerIQ FAQs 1 [12/12] FAQs Table of Contents FAQ 1. What size transformer will TransformerIQ monitor?... 2 FAQ 2. Are there different TransformerIQ versions?... 2 FAQ 3. How are the units powered?... 2 FAQ 4. What is

More information

Current and voltage measuring relays

Current and voltage measuring relays Current and voltage measuring relays RXIK 1, RXEEB 1 and Page 1 Issued June 1999 Changed since July 1998 Data subject to change without notice RXIK 1 RXEEB 1 (SE980082) (SE980081) (SE970869) Features Application

More information

Measurement of RF Emissions from a Final Coat Electronics Corrosion Module

Measurement of RF Emissions from a Final Coat Electronics Corrosion Module Engineering Test Report No. 37802-02 Rev. A Measurement of RF Emissions from a Final Coat Electronics Corrosion Module For : Canadian Auto Preservation, Inc. 390 Bradwick Drive Concord, Ontario CANADA

More information

Power Supply, Primary Switch Mode, Narrow Design MINI-PS-100-240AC/24DC/2

Power Supply, Primary Switch Mode, Narrow Design MINI-PS-100-240AC/24DC/2 Power Supply, Primary Switch Mode, Narrow Design -PS-100-240AC/24/2 POWER provides: Extra narrow widths of 22.5 and 45 mm (0.886 and 1.772 in.) Global use due to a wide range input A high level of operational

More information

Guidance for upgrading to GB4943.1-2011 (IEC 60950-1: 2005, MOD)

Guidance for upgrading to GB4943.1-2011 (IEC 60950-1: 2005, MOD) Guidance for upgrading to GB4943.1-2011 (IEC 60950-1: 2005, MOD) Note: This guidance document is a translation of official Chinese document which is issued by CQC (China Quality Certification Center) on

More information

Quick Connect. quick - simple - efficient. www.g-mw.de

Quick Connect. quick - simple - efficient. www.g-mw.de Quick Connect quick - simple - efficient www.g-mw.de Phone: +49 9103 7129-0 Fax: +49 9103 7129-207 Innovative connection technology to plug three single-phase current transformers to multifunctional power

More information

Agilent N8973A, N8974A, N8975A NFA Series Noise Figure Analyzers. Data Sheet

Agilent N8973A, N8974A, N8975A NFA Series Noise Figure Analyzers. Data Sheet Agilent N8973A, N8974A, N8975A NFA Series Noise Figure Analyzers Data Sheet Specifications Specifications are only valid for the stated operating frequency, and apply over 0 C to +55 C unless otherwise

More information

Fundamentals of Modern Electrical Substations Part 1: Mission of Electrical Substations and their Main Components

Fundamentals of Modern Electrical Substations Part 1: Mission of Electrical Substations and their Main Components Fundamentals of Modern Electrical Substations Part 1: Mission of Electrical Substations and their Main Components Course No: E02-010 Credit: 2 PDH Boris Shvartsberg, Ph.D., P.E., P.M.P. Continuing Education

More information

EMC STANDARDS STANDARDS AND STANDARD MAKING BODIES. International. International Electrotechnical Commission (IEC) http://www.iec.

EMC STANDARDS STANDARDS AND STANDARD MAKING BODIES. International. International Electrotechnical Commission (IEC) http://www.iec. EMC STANDARDS The EMC standards that a particular electronic product must meet depend on the product application (commercial or military) and the country in which the product is to be used. These EMC regulatory

More information

MYRICOM, INC. TEST REPORT FOR THE LAN INTERFACE CARD, M3F2-PCIXE-2

MYRICOM, INC. TEST REPORT FOR THE LAN INTERFACE CARD, M3F2-PCIXE-2 MYRICOM, INC. TEST REPORT FOR THE LAN INTERFACE CARD, M3F2-PCIXE-2 EN55024 (1998), EN61000-3-2 (2001), EN61000-3-3 (1995 W/A1: 98), EN55022 (1998) CLASS A, CISPR 22 (1997) CLASS A & FCC PART 15 SUBPART

More information

CPCI-3U-AC-300W-R. Rugged 300W AC Input 3U CompactPCI Power Supply. Electrical Specification for: Telkoor Part Number: 900-4602-0000

CPCI-3U-AC-300W-R. Rugged 300W AC Input 3U CompactPCI Power Supply. Electrical Specification for: Telkoor Part Number: 900-4602-0000 Electrical Specification for: CPCI-3U-AC-300W-R Rugged 300W AC Input 3U CompactPCI Power Supply Telkoor Part Number: 900-4602-0000 GENERAL SCALE RELEASE DATE 12/9/06 SHEET 1 OF 6 REVISION HISTORY Rev Level

More information