Phaseo power supplies

Size: px
Start display at page:

Download "Phaseo power supplies"

Transcription

1 ABL1, ABL7 and ABL8 Catalog 2011

2 2

3 Contents Product data website....4 Selection guides Overview Product descriptions: b ABL7/ABL8 Modular range...14 b ABL7/ABL8 Optimum range...20 b ABL8 Universal range...26 Function modules (for Universal range): v DC/DC Converter modules...36 v Buffer modules and Battery Control modules v Redundancy module b ABL1 Dedicated range b ASIABL AS-Interface range Product reference index

4 Go online to for technical information about products listed in this catalog, including: To learn more about Phaseo electronic switch mode power supply products, follow these steps Go to and enter Phaseo Power Supplies in the Search Box. 2. On the Search results page, select the first listing under Product & Technical Library entitled Power Supplies - Schneider Electric Schneider Electric On the Products page under Phaseo Regulated Switch Mode Power Supplies select from the following product lines, including: Modular, Optimum, Universal, Universal Function Modules and Dedicated Line.

5 > Specifications > Dimensions > References > Curves > Links to user guides and CAD files 4 For example...select the Phaseo Modular Line and click on Overview for Key Features and Applications Use the Product Selector to identify the Phaseo Power Supply with the right specifications to meet your requirements. 6 Select Documents & Downloads to view and select Product Brochures, Catalogs, Data Bulletins, Declarations, Handouts and Instruction Bulletins And, when you select Phaseo Universal Function Modules and click on Overview, you'll find out about the Uninterruptable Power Supply (UPS) System and the Interactive Demo.

6 Selection guide ABL7/ABL8 Modular and Optimum ranges Power supplies Regulated switch mode Phase Modular range and Optimum range industrial power supplies Input voltage Connection to United States world-wide line supplies V (in phase-to-neutral) V (in phase-to-phase) Europe V (in phase-to-neutral) V (in phase-to-phase) United States V (in phase-to-neutral) V (in phase-to-phase) IEC/EN conformity Protection against undervoltage Protection against overloads and short-circuits 100 to 240 V a 120 to 250 V c Single-phase (N-L1) or 2-phase (L1-L2) connection Single-phase (N-L1) connection Yes for ABL7RP, not for ABL8REM and not applicable for ABL8MEM and ABL7RM Yes Yes, voltage detection. Automatic restart on elimination on the detected fault Diagnostic relay Compatibility with function modules Power reserve (Boost) 1.25 to 1.4 In for 1 minute, depending on model (with ABL8MEM) No Output voltage 5 V c 12 V c 24 V c 48 V c Output current 0.3 A ABL8MEM24003 (Modular) 0.6 A ABL8MEM24006 (Modular) 1.2 A ABL8MEM24012 (Modular) 2 A ABL8MEM12020 (Modular) 2.5 A ABL7RM24025 (Modular) 3 A ABL8REM24030 (Optimum) 4 A ABL8MEM05040 (Modular) 5 A ABL7RP1205 (Optimum) 6 A 10 A ABL8REM24050 (Optimum) ABL7RP4803 (Optimum) 20 A 40 A Pages (Modular) and 20 (Optimum) 20 6 See more technical information online at

7 Selection guide ABL8 Universal range and DC/DC Converter modules Regulated switch mode Phaseo Universal range industrial power supplies ABL8DCC Function modules: Converter modules c 24 V/c 5-12 V 100 to 120 V a and 200 to 500 V a (1) 380 to 500 V a 24 V c Single-phase (N-L1) or 2-phase (L1-L2) connection 3-phase (L1-L2-L3) connection 3-phase (L1-L2-L3) connection Yes Yes Yes, current limitation or undervoltage detection Yes, current limitation Yes, depending on model Yes with buffer module, battery and battery control modules, redundancy module and discriminating downstream protection module 1.5 In for 4 seconds No 24 V c 5 V c 7 to 12 V c ABL8DCC12020 (2) ABL8RPS24030 ABL8RPS24050 ABL8DCC05060 (2) ABL8RPS24100 ABL8RPM24200 ABL8WPS24200 ABL8WPS (1) Except ABL8RPM a 100 to 120 V and a 200 to 240 V. (2) c/c converter module, requires to be associated with ABL8RP/ABL8WP power supply. See more technical information online at 7

8 Selection guide ABL1 Dedicated range Power supplies Regulated switch mode Phaseo Dedicated range power supplies for repetitive machines Input voltage Connection to United States world-wide line supplies V (in phase-to-neutral) V (in phase-to-phase) Europe V (in phase-to-neutral) V (in phase-to-phase) United States V (in phase-to-neutral) V (in phase-to-phase) 100 to 240 V a 120 to 370 V c Single-phase (N-L1) or 2-phase (L1-L2) connection Single-phase (N-L1) Single-phase (N-L1) IEC/EN conformity Yes for ABL1RP, not applicable for ABL1REM24025/12050 Protection against undervoltage Protection against overloads and short-circuits Yes, voltage detection. Automatic restart on elimination on the detected fault Diagnostic relay Compatibility with function modules Power reserve (Boost) No Output voltage 12 V c 24 V c Output current 2.5 A ABL1REM A 4.2 A ABL1RpM A 5 A ABL1REM A ABL1RpM A ABL1RPM A ABL1RpM24100 Pages 50 8 See more technical information online at

9 Selection guide AS-Interface range for AS-Interface cabling system Regulated switch mode Phaseo AS-Interface range for AS-Interface cabling system / 100 to 240 V a Single-phase (N-L1) connection Single-phase (N-L1) connection No Yes Yes Yes No 30 V c 24 V c ASIABLB3002 ASIABLD3002 (1) ASIABLM3024 (2) ASIABLM3024 (2) ASIABLB3004 (2) ASIABLD3004 (1) 56 (1) With ground fault detection. (2) One output 30 c and one output 24 c ± 5%. See more technical information online at 9

10 Overview Overview The Phaseo electronic switch mode power supply offer is designed to provide the DC voltage necessary for the PLC and automation system equipment control circuits. These power supplies include five ranges: vv Modular, Optimum and Universal ranges for common applications (ABL8 and ABL7) vvas-interface range for the AS-Interface cabling system (AS-Interface) vvdedicated range for repetitive equipment (ABL1) The Phaseo offer meets all the needs encountered in industrial, commercial and residential applications. With phase-to-neutral (N-L1), phase-to-phase (L1-L2) or 3-phase (L1-L2-L3) connection to the line supply, these electronic switch mode power supplies provide a quality of output current that is suitable for the loads supplied and compatible with the line supply available in the equipment. Clear guidelines are given for selecting protection devices which are often used with them, and thus a comprehensive solution is provided that can be used in total safety. Phaseo switch mode power supplies Phaseo switch mode power supplies are totally electronic and their output voltage is regulated. The use of electronics makes it possible to significantly improve the performance of these power supplies, which offer: bbvery compact size bbintegrated overload, short-circuit, overvoltage and undervoltage protection bbvery wide input voltage range for the Universal range bbhigh degree of output voltage stability bbgood performance bbdiagnostics via LED indicators on the front panel bbremote diagnostics via a relay contact for the Universal range Phaseo power supplies deliver a stabilized c output voltage that is precise to 3%, whatever the load from a a line supply, within the ranges of: bbfor Modular, Optimum, Dedicated and AS-Interface ranges: vv100 to 240 V a for phase-to-neutral (N-L1) or phase-to-phase (L1- L2) connection bbfor the Universal range: vv85 to 550 V a for phase-to-neutral (N-L1) or phase-to-phase (L1- L2) connection vv360 to 550 V a for 3-phase connection (L1-L2-L3) Conforming to IEC standards and UL, CSA, TÜV and C-Tick certified, they are suitable for industrial use. Phaseo power supplies also incorporate: bboutput voltage adjustment potentiometer in order to be able to compensate for any line voltage drops in installations with long cable runs b bdirect mounting on 35 mm DIN rails, optional on Dedicated range (1) (1) The Optimum and AS-Interface ranges can also take 75 mm DIN rails. 10

11 Overview (continued) Overview (continued) Phaseo switch mode power supplies (continued) Phaseo regulated switch mode industrial supplies are offered in three ranges (Modular, Optimum and Universal), complemented by the AS-Interface and Dedicated ranges for repetitive machines. ABL8MEM12020 Phaseo Modular range The Phaseo Modular range meets all the needs of simple automation systems with power ratings from 7 to 60 W and an output voltage of 5 V c, 12 V c or 24 V c. The shape and compact nature of its casing mean that it can be incorporated either in a modular panel or mounted on a DIN rail in a cabinet. Direct mounting on a panel (using its two retractable legs) and the choice of wires exiting at the top or bottom (except for the ABL7RM24025 model) make it an easy product to integrate. ABL8REM24030 Phaseo Optimum range The Phaseo Optimum range is the low-cost solution for applications supplied in 12 V c, 24 V c or 48 V c and requiring currents between 3 and 5 A. The Optimum range of Phaseo power supplies delivers a voltage that can guarantee the PLC logic states. In the event of an overload the power supply protection trips so that, once the detected fault has been eliminated, the power supply reverts to its nominal state. Since the Optimum range of Phaseo power supplies does not have PFC (Power Factor Correction), they do not meet the requirements of standard IEC/EN (except for ABL7RP1205/7RP4803 models). ABL8RPS24100 ABL8BUF24400 Phaseo Universal range The Universal range of Phaseo power supplies covers power ratings from 72 to 960 W in 24 V c and adapts to the majority of power distribution systems used throughout the world. The same power supply can thus be connected phase-to-neutral (N-L1) or phase-to-phase for line supplies ranging from 100 V a to 500 V a nominal. This product offering also includes three phase units. In addition, this range offers: bbdiagnostic functions (local or remote) bbuser choice of operating mode in the event of an overload (current limiting or stop) bbfunction modules to help ensure continuity of service: vvprotection against microbreaks or prolonged outages by means of the Buffer module and Battery Control modules vvparalleling and redundancy functions by means of the Redundancy module bbpower reserve (boost function) for absorbing the transient current peaks required by the application With the Universal range of power supplies, it is possible to satisfy the need for auxiliary voltage (5 V c to 15 V c) using c / c Converter modules. The incorporation of a PFC (Power Factor Correction) input filter reduces harmonic pollution to a minimum level across the entire Universal range, ensuring compliance with the requirements of standard IEC/EN ASIABLp30p4 ASIABLp3002 Phaseo AS-Interface range The 72 and 144 W AS-Interface range of Phaseo power supplies is designed to deliver a voltage of 30 V c, which is a prerequisite for the AS-Interface cabling system. These electronic switch mode power supplies with phase-to-neutral (N-L1) connection help ensure the quality of the output current in accordance with the electrical specifications and in compliance with standard EN ABL1RpMpp0pp ABL1RpM24100 Phaseo Dedicated range The Dedicated range of Phaseo power supplies from 60 to 240 W is designed for integration in repetitive equipment requiring a voltage of 12 V c or 24 V c. These electronic switch mode power supplies, with phase-to-neutral (N-L1) connection, with or without anti-harmonic filter and UL 508, CSA and TÜV certified, meet all the needs encountered in commercial machines and standard catalog machines. 11

12 Overview (continued) Specifications of the 24 V c operating voltage The permissible tolerances for the operating voltage are listed in publications IEC/EN and DIN For a nominal voltage Un of 24 V c, the extreme operating values are from - 15% to 20% of voltage Un, whatever the supply fluctuations in the range - 10% to 6% (defined by standard IEC 38) with load variations in the range 0 to 100% of nominal current In. All 24 V c are designed to provide an output voltage within these ranges. It may be necessary to use a voltage measurement relay to detect when the normal voltage limits are being surpassed and to deal with the consequences of this. The Universal range has integrated voltage detection. Recommendations for the use of 24 V c voltage The Phaseo power supplies can be used to supply control circuits with Protection Extra Low Voltage (PELV) or Safety Extra Low Voltage (SELV) in compliance with standard IEC/EN They have the following specifications: bbdouble insulation between the input circuit (connected to the line supply) and the low voltage output circuit via an integrated isolation transformer bbinternal device limiting the output voltage to less than 60 V in the event of an internal detected fault 12

13 Overview (continued) Harmonic pollution (power factor) The current drawn by a power supply is not sinusoidal. This leads to the generation of harmonic currents that pollute the distribution system. European standard IEC/ EN limits the harmonic currents produced by power supplies. This standard covers all devices between 75 and 1000 W, drawing up to 16 A per phase and connected directly to the public distribution system. Devices connected downstream of a private, low voltage general transformer are therefore excluded. Regulated switch mode supplies always consume harmonic currents; a filter circuit (Power Factor Correction or PFC) must therefore be added to comply with standard IEC/EN The ABL8RPS / 8RPM / 8WPS24pp0 Universal range and the ABL1RPM Dedicated range of Phaseo power supplies comply with standard EN and can therefore be connected directly to public distribution systems. Since the ABL8MEM240pp Modular range and ABL7RM24025 and ABL1REM12050/24025 Dedicated range of Phaseo power supplies have power ratings of < 75 W, they are not subject to the requirements of standard EN They can therefore be connected directly to public distribution systems. The ABL8REM Optimum range and the ABL1REM Dedicated range of Phaseo power supplies must only be connected downstream of a private, low voltage general transformer. 13

14 Introduction, description ABL7/ABL8 Modular range a ABL8MEMppppp c Zelio Logic Switch mode power supplies: Modular range The ABL8MEM/ABL7RM power supply offer is designed to provide the DC voltage necessary for the control circuits of automation system equipment consuming 7 to 60 W in 5, 12 and 24 V c. Comprised of six products, this range meets the needs encountered in industrial, commercial, and residential applications. These Modular electronic switch mode power supplies provide a quality of output current that is suitable for the loads supplied and compatible with the Zelio Logic range. Clear guidelines are given on selecting the upstream protection devices which are often used with them, and thus a comprehensive solution is provided that can be used in total safety. The Modular range of can be connected in phase-toneutral (N-L1) or in phase-to-phase (1) (L1-L2). They deliver a voltage that is precise to 3%, whatever the load and whatever the type of line supply, within a range of 85 to 264 V a. Conforming to IEC standards and UL, CSA and TUV certified, they are suitable for global use. They have overload and short-circuit protection. Due to their low power, the Modular range of Phaseo power supplies consume very little harmonic current and thus are not subject to the requirements of standard IEC/EN concerning harmonic pollution. All the Modular range of Phaseo power supplies have protection devices to help ensure optimum performance of the automation system with an automatic reset mode on elimination of the detected fault. All products are equipped with an output voltage adjustment potentiometer in order to be able to compensate for any line voltage drops in installations with long cable runs. These power supplies also have a cable channel on the side of the unit so that the output wires can be directed to the top or bottom of the product as required. They are designed for direct mounting on 35 mm DIN rails, or on a panel using their retractable mounting legs. There are six references available in the Phaseo Modular range: bbabl8mem W 0.3 A 24 V c bbabl8mem W 0.6 A 24 V c bbabl8mem W 1.2 A 24 V c bbabl7rm W 2.5 A 24 V c bbabl8mem W 4 A 5 V c bbabl8mem W 2 A 12 V c (1) 240 V a nominal. Description ABL8MEMpppp 7 1 ABL7RM AWG (2.5 mm 2 ) screw terminal for connection of the AC input voltage 2 Output voltage adjustment potentiometer 3 14 AWG (2.5 mm 2 ) screw terminal for connection of the output voltage 4 LED indicating presence of the DC output voltage 5 Channel for through-wiring of the output voltage conductors at the bottom (except for model ABL7RM24025) 6 Clip-on marker label (except for model ABL7RM24025) 7 Retractable mounting legs for panel mounting 14

15 Specifications ABL7/ABL8 Modular range Technical specifications Power supply type ABL8MEM24003 ABL8MEM24006 ABL8MEM24012 ABL7RM24025 Certifications culus 508, ccsaus (CSA22.2 n950-1), TÜV , e, CTick, RoHS Conformity to standards Safety IEC/EN , SELV Input circuit LED indication EMC Input values Nominal voltage V 100 to 240 Vac Output circuit LED indication Limit voltage V 85 to 264 Vac 120 to 250 Vdc (1) Current consumption A 0.25 (100 Vac) 0.18 (240 Vac) Permissible frequencies Hz 47 to 63 IEC/EN , IEC/EN , IEC/EN , EN Class B No 0.4 (100 Vac) 0.25 (240 Vac) 0.65 (100 Vac) 0.4 (240 Vac) 85 to 264 Vac 1.2 (120 Vac) 0.7 (240 Vac) Maximum inrush current A for 1 ms Power factor > 0.5 Efficiency at nominal load > 78% > 80% > 82% > 84% Dissipated power at nominal load W Green LED Nominal output values Voltage (UOut) V 24 Vdc Current A Power W Precision Output voltage V Adjustable from 22.8 to 28.8 Vdc Line and load regulation ± 3% Residual ripple - noise mv Holding time for I max. UIn = 100 Vac ms u 10 UIn = 230 Vac ms u 150 Protection Against short circuits Permanent Against undervoltages V < 19 Thermal Yes Operating and environmental specifications Connections Input AWG (mm 2 ) 26 to 14 (2 x 0.14 to 2.5) screw terminals Output AWG 26 to 14 (2 x 0.14 to 2.5) 26 to 14 (4 x 0.14 to 2.5) screw terminals (mm 2 ) screw terminals Mounting On DIN rail, 35 x 7.5 mm and 35 x 15 mm or on panel (2 x ø 4 mm) Operating position On vertical plane Vertical Connections Series Possible Parallel Possible Environment Operating temperature F ( C) -13 to 158 derating from 131 F (-25 to 70 derating from 55 C), -13 to 131 F (-25 to 55 C) Storage temperature F ( C) -40 to 158 F (-40 to 70 C) Relative humidity 90% during operation, 95% in storage Degree of protection IP 20 conforming to IEC Vibration per to EN to 11.9 Hz, amplitude 0.14 in. (3.5 mm); and Hz, acceleration 2 g Protection class according to VDE Class II Dielectric strength 50 Hz for Input/output V rms 3000 Vac 1 min Input fuse incorporated Yes (not interchangeable) Emissions EN (generic) according to EN Radiation EN Class B Conducted on the power line EN Class B Harmonic currents IEC/EN Immunity IEC (generic) according to EN Electrostatic discharge IEC/EN (6 kv contact/8 kv air) IEC/EN (4 kv contact/8 kv air) Radiated electromagnetic fields IEC/EN level 3 (10 V/m) Induced electromagnetic fields IEC/EN level 3 (10 V/m) Rapid transients IEC/EN (4 kv) Surges IEC/EN (1 kv) Primary outages IEC/EN (voltage dips and interruptions) (1) DC input voltages are not included in culus, ccsaus, and TÜV certifications. 15

16 Specifications (continued) ABL7/ABL8 Modular range Technical specifications Power supply type ABL8MEM05040 ABL8MEM12020 Certifications culus 508, ccsaus (CSA22.2 n950-1), TÜV EN , e, CTick, RoHS Conformity to standards Safety IEC/EN , SELV EMC IEC/EN , IEC/EN , IEC/EN , EN Class B Input circuit LED indication Input values Output circuit LED indication Nominal output values Precision Holding time for I max Protection No Nominal voltage V 100 to 240 Vac Limit voltage V 85 to 264 Vac 120 to 250 Vdc (1) Current consumption A 0.55 (100 Vac) 0.35 (240 Vac) 0.6 (100 Vac) 0.35 (240 Vac) Permissible frequencies Hz 47 to 63 Maximum inrush current A 20 Power factor > 0.5 Efficiency at nominal load > 75% > 80% Dissipated power at nominal load W Green LED Voltage (UOut) V 5 Vdc 12 to 15 Vdc Current A Power W Output voltage V Adjustable from 4.75 to 6.25 Adjustable from 11.4 to 15 Line and load regulation ± 3% Residual ripple - noise mv 250 UIn min ms u 10 Against short circuits Permanent Against undervoltages Thermal Operating and environmental specifications Connections Input Output AWG (mm 2 ) AWG (mm 2 ) 26 to 14 (2 x 0.14 to 2.5) screw terminals 26 to 14 (4 x 0.14 to 2.5) screw terminals Mounting On DIN rail, 35 x 7.5 mm and 35 x 15 mm or on panel (2 x ø 4 mm) Operating position On vertical plane Vertical Connections Series Possible Parallel Possible Operating temperature F ( C) -13 to 158 derating from 131 F (-25 to 70 derating from 55 C) Storage temperature F ( C) -40 to 158 F (-40 to 70 C) Environment Maximum relative humidity 90% during operation 95% in storage Degree of protection IP 20 conforming to IEC Vibration 3 to 11.9 Hz, amplitude 0.14 in (3.5 mm); and Hz, acceleration 2 g Protection class according to VDE Class II Dielectric strength 50 Hz for 1 min Input/output V rms 3000 Vac Input fuse incorporated Yes (not interchangeable) EN (generic) Emissions Radiation EN Class B according to EN Conducted on the power line EN Class B Harmonic currents IEC/EN IEC (generic) Electrostatic discharge IEC/EN (6 kv contact/8 kv air) Radiated electromagnetic fields IEC/EN level 3 (10 V/m) Immunity Induced electromagnetic fields IEC/EN level 3 (10 V/m) according to EN Rapid transients IEC/EN (4 kv) Surges IEC/EN (1 kv) Primary outages IEC/EN (voltage dips and interruptions) (1) DC input voltages are not included in culus, ccsaus, and TÜV certifications. 16

17 Specifications (continued) ABL7/ABL8 Modular range Output specifications Behavior when short circuits and overloads occur are equipped with an electronic protection device. When an overload or short circuit occurs, the integrated protection interrupts the current supply before the output voltage drops below 19 V. The output voltage reverts to its nominal value upon elimination of the detected fault, eliminating the need to take any action. Derating The ambient temperature is a determining factor which limits the power that an electronic power supply can deliver continuously. Excessively high temperatures around the electronic components significantly reduce their life. The nominal ambient temperature for the Modular range of Phaseo power supplies is 131 F (55 C). Above this temperature, derating is necessary up to a maximum temperature of 158 F (70 C) (except for the ABL7RM24025 model). P/Pn (%) 100 % 1 2 The graph to the left shows the power as a percentage of the nominal power that the power supply can deliver continuously, depending on the ambient temperature. 30 % - 13 (- 25) 23 (- 5) 59 (15) 95 (35) 131 (55) 158 (70) 167(75) Maximum operating temperature, F ( C) 1 With an ABL7RM With an ABL8MEMppppp Temporary overloads The ABL8MEMpppp Modular range of power supplies have an energy reserve that can be used to supply the application with 125% to 140% of the nominal output current for a maximum of 1 minute, depending on the model. Series or parallel connection Series connection Parallel connection ABL7RM ABL8MEM ABL7RM ABL8MEM ABL7RM ABL8MEM ABL7RM ABL8MEM x 24 Vdc/I out 24 Vdc/2 x I out 1 Two shottky diodes, Imin = power supply In, and Vmin = 50 V Family Series Parallel ABL7RM / 8MEM 2 products max. 2 products max. NOTE: Series or parallel connection is recommended only for products with identical catalog numbers. 17

18 Protection, wiring diagrams ABL7/ABL8 Modular range Selection of protection for the power supply primary Type of line supply 100 to 240 V a single-phase Type of protection Thermal-magnetic circuit-breaker Class CC fuse GB2 (IEC) C60N (IEC) C60N (UL/CSA) ABL8MEM05040 GB2 pp07 (1) A ABL8MEM12020 ABL8MEM24003 ABL8MEM24006 ABL8MEM24012 ABL7RM24025 GB2 pp08 (1) A (1) Complete the reference by replacing pp as required: - CB for single-pole circuit-breaker with magnetic trip threshold 12 to 16 In - CD for single-pole neutral circuit-breaker with magnetic trip threshold 12 to 16 In - DB for 2-pole circuit-breaker with magnetic trip threshold 12 to 16 In - CS for single-pole circuit-breaker with magnetic trip threshold 5 to 7 In Wiring diagrams GB2CBpp GB2CDpp GB2DBpp GB2CSpp 2/T1 1/L1 4/T2 (14) 3/L2 (13) 2/T1 1/L1 2/T1 1/L1 4/T2 3/L2 2/T1 1/L1 18

19 References, dimensions, wiring diagrams ABL7/ABL8 Modular range References ABL8MEM05040/12020/24012 Input voltage Secondary Reset Conforming Output Nominal Nominal to standard voltage power current IEC/EN (1) Single-phase (N-L1) or 2-phase (L1-L2) connection 100 to 240 V -15%, 10% 50/60 Hz Reference Weight lbs (kg) 5 V c 20 W 4 A Automatic Not applicable ABL8MEM (0.23) 12 V c 25 W 2 A Automatic Not applicable ABL8MEM (0.23) 24 V c 7 W 0.3 A Automatic Not applicable ABL8MEM (0.13) 15 W 0.6 A Automatic Not applicable ABL8MEM (0.13) ABL8MEM24003/ W 1.2 A Automatic Not applicable ABL8MEM (0.23) 60 W 2.5 A Automatic Not applicable ABL7RM (0.32) Designation Use Order in multiples of Unit reference Weight lbs (kg) Clip-on marker Replacement parts for ABL8MEM power supplies 100 LAD labels (0.03) ABL7RM24025 (1) Due to their power < 75 W, the Modular range of power supplies is not subject to the requirements of standard IEC/EN Approximate dimensions ABL8MEMppppp / ABL7RM24025 power supply a a (90) (100) ABL8MEM (53) 1.65 (42) ABL8MEM (53) 1.65 (42) ABL8MEM (36) 0.94 (24) ABL8MEM (36) 0.94 (24) ABL8MEM (53) 1.65 (42) ABL7RM (72) 2.36 (60) (44) (4) a (59) a in (mm) Wiring diagrams ABL8MEM2400p ABL8MEM05040 / 8MEM12020 / 8MEM24012 / 7RM24025 L N L (110) N 19

20 Introduction, description ABL7/ABL8 Optimum range a ABL8REM24030 c Twido Switch mode power supplies: Optimum range The ABL8REM/7RP power supply offer is designed to provide the DC voltage necessary for the control circuits of automation system equipment consuming 60 to 144 W in 12, 24 and 48 V c. Comprised of four products, this range meets the needs encountered in industrial, commercial, and residential applications. With phase-to-neutral (N-L1) or phase-to-phase (1) (L1-L2) connection, these slim electronic switch mode power supplies provide a quality of output current that is suitable for the loads supplied and compatible with both the Twido range and the smallest Modicon M340 configurations, making them ideal partners. Their simplified specifications in comparison with the Universal offer also make them the low-cost solution for applications less affected by problems with the line supply, such as harmonic pollution and outages. Clear guidelines are given on selecting the upstream protection devices which are often used with them, and thus a comprehensive solution is provided that can be used in total safety. The Optimum range of delivers a voltage that is precise to 3%, whatever the load and whatever the type of line supply, within a range of 85 to 264 V a. Conforming to IEC standards and UL, CSA and TUV certified, they are suitable for global use. They have overload and short-circuit protection. ABL8REM power supplies do not have anti-harmonic filters and do not satisfy the requirements of standard IEC/EN concerning harmonic pollution. ABL7RP power supplies, however, are equipped with a PFC (Power Factor Correction) filter, thus ensuring compliance with standard IEC/EN The Optimum range of Phaseo power supplies includes protection devices to help ensure optimum performance of the automation system with an automatic reset mode on elimination of the detected fault. In the event of an overload or short-circuit, the integrated protection interrupts the current supply before the output voltage drops below 19 V c. The protection device resets itself automatically on elimination of the detected fault, which avoids having to take any action or change a fuse. All products are equipped with an output voltage adjustment potentiometer in order to be able to compensate for any line voltage drops in installations with long cable runs. These power supplies are designed for direct mounting on 35 and 75 mm DIN rails. There are four references available in the Optimum range of Phaseo power supplies: bbabl8rem W 3 A 24 V c bbabl8rem W 5 A 24 V c bbabl7rp W 5 A 12 V c bbabl7rp W 3 A 48 V c Description 1 14 AWG (2.5 mm 2 ) enclosed screw terminals for connection of the input voltage (single-phase N-L1, phase-to-phase L1-L2 (1)) 2 Protective glass flap 3 Input voltage status LED (orange). 4 Output DC voltage status LED (green). 5 Locking catch for the glass flap (sealable) 6 Clip-on marker label. 7 Output voltage adjustment potentiometer 8 14 AWG (2.5 mm 2 ) enclosed screw terminal block for connection of the DC output voltage (1) 240 V a nominal 8 20

21 Specifications ABL7/ABL8 Optimum range Technical specifications Type of power supply ABL7RP1205 ABL7RP4803 ABL8REM24030 ABL8REM24050 Certifications Conformity to standards Input circuit LED indication Input values Output circuit LED indication Nominal output values Precision culus 508, ccsaus (CSA22.2 n950-1), File Class, TÜV , e, CTick, RoHS Safety IEC/EN 60950, IEC/EN , SELV IEC/EN 60950, SELV EMC EN , IEC (EN ) Nominal voltage Limit voltage Current consumption V V Orange LED 100 to 240 Vac compatible with 110 to 220 Vdc (1) 85 to 264 Vac compatible with 100 to 250 Vdc (1) 100 to 240 Vac compatible with 110 to 220 Vdc (1) 85 to 264 Vac single-phase compatible with 100 to 250 Vdc (1) UIn = 240 Vac A UIn = 100 Vac A Permissible frequencies Hz 47 to 63 Maximum inrush current A 30 Power factor 0.98 approx approx. Efficiency at nominal load > 85% Dissipated power at nominal load W Green LED Voltage (UOut) V 12 Vdc 48 Vdc 24 Vdc Current A Power W Output voltage Adjustable from Adjustable from V 12 to 14.4 Vdc 48 to 57.6 Vdc Adjustable from 24 to 28.8 Vdc Line and load regulation ± 3% Residual ripple - noise mv < 200 (peak-peak) Holding time for I max UIn = 240 Vac ms UIn = 100 Vac ms Protection Against short circuits Permanent/automatic or manual restart Permanent/automatic restart Against overloads 1.1 In Against overvoltages Tripping if UOut > 1.5 Un Against undervoltages Tripping if UOut < 0.8 Un Operating and environmental specifications Connections Input AWG (mm 2 ) 26 to 14 (2 x 0.14 to 2.5) screw terminals ground Output AWG (mm 2 ) 26 to 14 (2 x 0.14 to 2.5) screw terminals ground, multiple output, depending on model Mounting On DIN rail in (mm) 1.38 x.30, 1.38 x.59 and 2.95x.30 (35 x 7.5, 35 x 15 and 75 x 7.5) Operating position On vertical plane Vertical Connections Series Possible Parallel Possible Degree of protection IP 20 conforming to IEC Environment Operating temperature F ( C) 32 to 140 derating from 122 F (0 to 60 derating from 50 C) Storage temperature F ( C) -13 to 158 F (-25 to 70 C) Maximum relative humidity 95% without condensation or dripping water Vibration per to EN to 11.9 Hz, amplitude 0.14 in (3.5 mm); and 11.9 to 150 Hz, acceleration 2 g Protection class according to VDE Class I Dielectric strength 50 and 60 Hz for 1 min Input/output V rms 3000 Vac Input/ground V rms 3000 Vac Output/ground (and output/output) V rms 500 Vac Input fuse incorporated Yes (not interchangeable) Emissions EN (generic) according to EN Conducted/radiated EN 55011/EN cl. B Immunity IEC (generic) according to Electrostatic discharge IEC/EN (6 kv contact/8 kv air) EN Radiated electromagnetic fields IEC/EN level 3 (10 V/m) Induced electromagnetic fields IEC/EN level 3 (10 V/m) Rapid transients EN level 3 (2 kv) Surges IEC/EN (2 kv) Primary outages IEC/EN (voltage dips and interruptions) (1) DC input voltages are not included in culus, ccsaus, and TÜV certifications. 21

22 Specifications (continued) ABL7/ABL8 Optimum range Output specifications Derating The ambient temperature is a determining factor which limits the power that an electronic power supply can deliver continuously. Excessively high temperatures around the electronic components significantly reduce their life. The nominal ambient temperature for the Optimum range is 122 F (50 C). Above this temperature, derating is necessary up to a maximum temperature of 140 F (60 C). The graph below shows the power as a percentage of the nominal power that the power supply can deliver continuously, depending on the ambient temperature (0) 50 (10) 68 (20) 86 (30) 104 (40) 122 (50) 140 (60) 158 (70) Maximum operating temperature F ( C) 1 ABL8REM, ABL7RP mounted vertically Derating should be considered in extreme operating conditions: bbintensive operation (output current permanently close to the nominal current, combined with a high ambient temperature) b boutput voltage set above 24 Vdc (to compensate for line voltage drops, for example) bbparallel connection to increase the total power General rules 1.97 (50) Intensive operation See derating in above graph. Example for ABL8REM: bb Without derating, from 32 to 122 F (0 to 50 C) bb Derating of nominal current by 2% per additional C, up to 60 C. See chart (10) AUTO MANU 0.59 (10) Rise in output voltage Parallel connection to increase the total power The nominal power is mounted. Increasing the output voltage means that the current delivered must be reduced. The total power is equal to the sum of the power supplies used, but the maximum ambient temperature for operation is 122 F (50 C). To improve heat dissipation, the power supplies must not be in contact with each other (50) in (mm) In all cases, there must be adequate convection around the products to assist cooling. There must be sufficient clearance around the Optimum range Phaseo power supplies: bb1.97 inches (50 mm) above and below bb0.59 inches (15 mm) on the sides 22

23 Specifications (continued) ABL7/ABL8 Optimum range Output specifications (continued) Load limit ABL8REM240pp / ABL7RPpppp Temporary overloads ABL8REM / ABL7RP U out T (ms) 20 I out I out:( %) 24 Vdc Vdc In 1.1 x In I out x In Series or parallel connection Series connection Parallel connection ABL7RP ABL8REM ABL7RP ABL8REM ABL7RP ABL8REM ABL7RP ABL8REM x 24 Vdc/I out 24 Vdc/2 x I out 1 Two shottky diodes, Imin = power supply In, and Vmin = 50 V Family Series Parallel ABL8REM / 7RP 2 products max. 2 products max. Series or parallel connection is recommended only for products with identical catalog numbers. T (ms) I out 20 I out:( %) I out x In 23

24 Protection, wiring diagrams ABL7/ABL8 Optimum range Selection of protection for the power supply primary Type of line supply (Single Phase) 100 V a 240 V a Type of protection Thermal-magnetic circuit-breaker GB2 (IEC) C60N (IEC) C60N (UL) ABL7RP1205 GB2 pp06 (1) Class CC fuse Thermal-magnetic circuit-breaker GB2 (IEC) C60N (IEC) C60N (UL) 2 A GB2 pp06 (1) Class CC fuse 1 A ABL8REM24030 GB2 pp07 (1) ABL8REM24050 GB2 pp07 (1) ABL7RP4803 GB2 pp07 (1) A GB2 pp06 (1) A GB2 pp06 (1) A GB2 pp06 (1) A 1 A 1 A (1) Complete the reference by replacing pp with CB for single-pole circuit-breaker with magnetic trip threshold 12 to 16 In CD for single-pole neutral circuit-breaker with magnetic trip threshold 12 to 16 In DB for 2-pole circuit-breaker with magnetic trip threshold 12 to 16 In CS for single-pole circuit-breaker with magnetic trip threshold 5 to 7 In Wiring for GB2pp0p thermal-magnetic circuit protectors GB2CBpp GB2CDpp GB2Dpp GB2CSpp 2/T1 1/L1 4/T2 (14) 3/L2 (13) 2/T1 1/L1 2/T1 1/L1 4/T2 3/L2 2/T1 1/L1 24

25 References, dimensions, wiring diagrams ABL7/ABL8 Optimum range : Phaseo Optimum range Input voltage Secondary Reset Conforming Output Nominal Nominal to standard voltage power current CEI/EN Single-phase (N-L1) or phase-to-phase (L1-L2) connection 100 to 240 V a - 15%, 10% 50/60 Hz 12 V c 60 W 5 A Automatic or manual Reference Weight lbs (kg) Yes ABL7RP (1.08) ABL7RP1205/ V c 72 W 3 A Automatic No ABL8REM (0.55) 120 W 5 A Automatic No ABL8REM (0.79) ABL8REM24030 ABL8REM V c 144 W 2.5 A Automatic or manual Yes ABL7RP (1.08) Approximate dimensions ABL7RPpppp Common side view Mounted on 35 and 75 mm DIN rails ABL8REM24030 ABL7RP1205/4803 ABL8REM (120) (120) (120) (54) (54) in (mm) Wiring diagrams ABL7RP1205 / ABL8REM24030 ABL8REM24050 N/ L/ L N N L 4.92 (125) (27) 25

26 Introduction ABL8 Universal range a c ABL8RPS24050 Modicon M340 automation platform Switch mode power supplies: Universal range The ABL8RPS/RPM/WPS power supply offer is designed to provide the DC voltage necessary for the control circuits of automation system equipment. Comprised of six products, this range meets the needs encountered in industrial and commercial applications. These compact electronic switch mode power supplies provide a quality of output current that is suitable for the loads supplied and compatible with the Modicon M340, Premium and Quantum ranges. When used with additional function modules, they help ensure continuity of service in the event of network power outages or application malfunctions. Clear guidelines are given on selecting the function modules and upstream protection devices which are often used with them, and thus a comprehensive solution is provided that can be used in total safety. The Universal range of must be connected in phase-to-neutral or phase-to-phase for ABL8RPS/RPM, and in three-phase for ABL8WPS. They deliver a voltage that is precise to 3%, whatever the load and whatever the type of line supply, within the ranges: bb85 to 132 V a and 170 to 550 V a for ABL8RPS bb85 to 132 V a and 170 to 264 V a for ABL8RPM bb340 to 550 V a for ABL8WPS Their very wide input voltage range allows a considerable reduction of parts held in stock and offers a distinct advantage in terms of machine design. Conforming to IEC standards and UL and CSA certified, they are suitable for global use. ABL8RPS/RPM and ABL8WPS power supplies are all equipped with a harmonic filter, ensuring compliance with standard IEC/EN concerning harmonic pollution. All the Universal range of Phaseo power supplies have protection devices to help ensure optimum performance of the automation system. Their operating mode can be configured as required by the user: vvmanual reset protection mode: Priority is given to the voltage so as to guarantee the PLC logic states and nominal operation of the supplied actuators. vvautomatic reset protection mode: Priority is given to the current to allow troubleshooting for example, or to help ensure continuity of service until the arrival of the maintenance team. The Universal range of Phaseo power supplies also has a power reserve, allowing them to deliver a current of 1.5 In at regular intervals. This avoids the need to oversize the power supply if the device has a high inrush current, while ensuring optimum performance of the automation system. The diagnostics for the Universal range of Phaseo power supplies are available on the front of the device via LEDs (UOut and IOut) and via a dry contact relay. All products are equipped with an output voltage adjustment potentiometer in order to be able to compensate for any line voltage drops in installations with long connection cable runs. These power supplies are designed for direct mounting on a 35 mm DIN rail. 26

27 Introduction (continued), description ABL8 Universal range a ABL8WPS24200 Switch mode power supplies: Universal range (continued) There are four references available in the Universal range of Phaseo power supplies for phase-to-neutral or phase-to-phase connection: b babl8rps W 3 A 24 V c bbabl8rps W 5 A 24 V c bbabl8rps W 10 A 24 V c bbabl8rpm W 20 A 24 V c The Universal range of Phaseo power supplies also features two references for three-phase connection: bbabl8wps W 20 A 24 V c bbabl8wps W 40 A 24 V c c Modicon Premium automation platform A range of function modules also allows functions to be added to the Universal range of Phaseo power supplies so as to help ensure continuity of service: vvbuffer module or Battery Control modules combined with batteries to help ensure continuity of service in the event of a network power outage vvredundancy module to meet the most demanding requirements for continuity of service even if the power supply fails vvconverter modules delivering nominal voltages of 5 and 12 V c from the 24 V c output of the Universal range of Phaseo power supplies Description Universal range of power supplies The Universal range of Phaseo regulated switch mode power supplies, ABL8RPS24pp0/RPM24200/WPS24p00, is comprised of: 1 Spring clip for 35 mm DIN rail 2 12 AWG (4 mm 2 ) enclosed screw terminals for connection of the AC voltage (single-phase, phase-to-phase or three-phase connection) 3 Protective glass flap 4 Clip-on marker label 5 Locking catch for the glass flap (sealable) 6 Protection mode selector 7 Output voltage adjustment potentiometer 8 Output voltage status LED (green and red) (1) 9 Output current status LED (green, red and orange) 10 Screw terminals for connection of the diagnostic relay contact, except ABL8RPS AWG (4 mm 2 ) [8 AWG (10 mm 2 ) on ABL8WPS24p00 and ABL8RPM24200] enclosed screw terminals for connection of the DC output voltage (1) See "LED Descriptions" on page

28 Specifications ABL8 Universal range Technical specifications Type of power supply ABL8RPS24030 ABL8RPS24050 ABL8RPS24100 ABL8RPM24200 Certifications Conformity to standards Input circuit Input values phase-to-neutral (N-L1) or phase-to-phase (L1-L2) Anti-harmonic filtering Output circuit CB scheme EN , culus 508, ccsaus, e, RoHS Safety IEC/EN , EN 61204, SELV EMC EN , EN , EN , EN , EN Nominal voltage V 100 to 120 / 200 to 500 Vac 100 to 120 / 200 to 240 Vac Limit voltage V 85 to 132 / 170 to 550 Vac 85 to 132 / 170 to 264 Vac Permissible frequencies Hz 47 to 63 Maximum inrush current A 30 for 2 ms max. Power factor 0.59 at 120 Vac / 0.51 at 240 Vac 0.69 at 120 Vac / 0.68 at 240 Vac Efficiency at nominal load > 87 % > 88 % Dissipated power at nominal load W Yes, via integrated PFC passive filter Compatibility with function modules Buffer, battery and battery control unit, and redundancy LEDs on front panel Current (green, orange, and red), voltage (green, red, and off) Diagnostics Relay closed UOut > 21.6 V Relay contact 230 Vac, 0.5 A max; 24 Vdc, 5 ma min Nominal output voltage (UOut) V 24 Vdc Nominal output values Current A Power W Permissible temporary inrush current (boost) A 1.5 In for 4 s maximum Nominal output voltage (UOut) V Adjustable 24 to 28.8 Vdc Precision Line and load regulation 1 % to 3 % Residual ripple - noise mv < 200 (peak-peak) UIn = 100 Vac ms u 20 Holding time for I max. UIn = 240 Vac ms u 40 UIn = 400 Vac ms u 120 Against short circuits Permanent, automatic or manual restart Against overloads < 1.10 In (after boost function) Protection Against overvoltages V 30 to 32 Vdc Against undervoltages V Tripping if UOut < 21.6 (in manual mode) Thermal Yes LED Descriptions U out I out 21.6 V y Uout Iout y In 7 V y Uout < 21.6 V Uout < 7 V In y Iout Power supply shut off State of protection 0 V / 0 A / / / OFF Green Orange Red 28

29 Specifications (continued) ABL8 Universal range Operating and environmental specifications Type of power supply ABL8RPS24030 ABL8RPS24050 ABL8RPS24100 ABL8RPM24200 Connections Input Output Diagnostic relay AWG (mm 2 ) AWG (mm 2 ) AWG (mm 2 ) 22 to 12 (2 x 0.5 to 4) screw terminals ground terminal 24 to 10 (4 x 0.5 to 4) screw terminals ground terminal 14 (2 x 2.5) removable screw terminal block Mounting On DIN rail in/mm 1.38 x 0.30 and 1.38 x 0.59 (35 x 7.5 and 35 x 15) Operating position Connections Series Parallel Vertical Possible Possible Degree of protection IP 20 conforming to IEC Environment Operating temperature F ( C) -13 to 140 derating from 122 F (-25 to 60 derating from 50 C) Storage temperature F ( C) -40 to158 F (-40 to 70 C) Maximum relative humidity Vibration per to EN Protection class According to VDE Class I Dielectric strength 50 Hz for 1 min Input fuse incorporated Emissions according to EN Immunity according to EN and GL 90% during operation, 95% in storage 3 to 11.9 Hz, amplitude 0.14 in (3.5 mm); and 11.9 to 150 Hz, acceleration 2 g Input/output V rms 4000 Vac 3000 Vac Input/ground V rms 3500 Vac 2500 Vac Output/ground V rms 500 Vac Radiation Conducted on the power line No EN Class B and GL levels EN Class B and GL levels Harmonic currents IEC/EN Electrostatic discharge Radiated electromagnetic fields Induced electromagnetic fields Rapid transients Surges Primary outages IEC/EN (6 kv contact/8 kv air) IEC/EN level 3 (10 V/m) IEC/EN level 3 (10 V/m) IEC/EN (4 kv) IEC/EN (2 kv) IEC/EN (voltage dips and interruptions) 29

30 Specifications (continued) ABL8 Universal range Technical specifications Type of power supply ABL8WPS24200 ABL8WPS24400 Certifications CB scheme EN , culus 508, ccsaus, e, RoHS Conformity to standards Safety EN , EN 61204, SELV EMC EN , EN , EN , EN , EN Input circuit LED indication Input values 3 phases (L1-L2-L3) Anti-harmonic filtering Nominal values V Vac Permissible values V Vac Permissible frequencies Hz 47 to 63 Maximum inrush current A 25 for 2 ms max. Power factor Efficiency at nominal load > 92% Dissipated power at nominal load W Yes, via integrated PFC passive filter Operating mode in the event of phase failure V Operation possible for a few minutes then protection trips Output circuit Compatibility with function modules Buffer, battery and battery control unit, and redundancy Diagnostics LEDs on front panel Current (green, orange, and red), voltage (green, red, and off) Relay Closed relay UOut > 21.6 V, contact 230 Vac, 0.5 A max; 24 Vdc, 5 ma min Output voltage (UOut) V 24 Vdc Nominal output values Current A 0 to 20 0 to 40 Power W Permissible temporary inrush current (boost) A 1.5 In for 4 s maximum Output voltage (UOut) V Adjustable 24 to 28.8 Vdc Precision Line and load regulation 1% to 3% Residual ripple - noise mv < 200 (peak-peak) Holding time for I max UIn = 400 Vac ms u 18 u 14 Against short circuits Permanent, automatic or manual restart Against overloads < 1.10 In (after boost function) Protection Against overvoltages V 30 to 32 Vdc Against undervoltages V Tripping if UOut < 21.6 (in manual mode) Thermal Yes Operating and environmental specifications Connections Input Output Diagnostic relay AWG (mm 2 ) AWG (mm 2 ) AWG (mm 2 ) 2212 (3 x 0.5 to 4) screw terminals ground 228 (4 x 0.5 to 10) screw terminals 14 (2 x 2.5) removable screw terminal block Mounting On DIN rail in (mm) 1.38 x 0.30 and 1.38 x 0.59 (35 x 7.5 and 35 x 15) Operating position Vertical Connections Series Possible Parallel Possible Degree of protection IP 20 conforming to IEC Operating temperature F ( C) -13 to 140 derating from 122 F (-25 to 60 derating from 50 C) Environment Storage temperature F ( C) -40 to 158 F (-40 to 70 C) Maximum relative humidity 90% during operation, 95% in storage Vibration per to EN to 11.9 Hz, amplitude 0.14 in (3.5 mm); and 11.9 to150 Hz, acceleration 2 g Protection class according to VDE Class I Dielectric strength 50 Hz for 1 min Input fuse incorporated Emissions according to EN Immunity according to EN and GL Input/output V rms 4000 Vac Input/ground V rms 3500 Vac Output/ground V rms 500 Vac No Radiation EN Class B and GL levels Conducted on the power line EN Class B and GL levels Harmonic currents IEC/EN Electrostatic discharge IEC/EN (6 kv contact/8 kv air) Radiated electromagnetic fields IEC/EN level 3 (10 V/m) Induced electromagnetic fields IEC/EN level 3 (10 V/m) Rapid transients IEC/EN (4 kv) Surges IEC/EN (1 kv) Primary outages IEC/EN (voltage dips and interruptions) 30

7 - Phaseo power supplies and transformers

7 - Phaseo power supplies and transformers /0 Contents 0 - Phaseo power supplies and transformers Selection guide: Phaseo power supplies Modular, Optimum and universal ranges........................ page /2 Selection guide: Phaseo power supplies

More information

Power Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1

Power Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1 Power Supply Unit, Primary Switched, Narrow Design MINI POWER provides: Extra narrow design with widths of 22.5 mm, 45 mm, and 67.5 mm (0.886, 1.772, and 2.657 in.) Global use due to a wide-range input

More information

RM17TE 183...528 V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

RM17TE 183...528 V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC Characteristics multifunction control relay RM17-TE - range 183..528 V AC Complementary Reset time Maximum switching voltage Minimum switching current Maximum switching current [Us] rated supply voltage

More information

STEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: 2868567. DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase

STEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: 2868567. DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase Extract from the online catalog STEP-PS/1AC/12DC/1.5 Order No.: 2868567 DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase Commercial data EAN 4046356292924 Pack 1 pcs. Customs tariff

More information

RM35UA13MW. range 15..600 V. Main. Product or component type. Relay monitored parameters

RM35UA13MW. range 15..600 V. Main. Product or component type. Relay monitored parameters Characteristics multifunction voltage control relay RM35-U - range 15..600 V Complementary Reset time Maximum switching voltage [Us] rated supply voltage Supply voltage limits Power consumption in W Main

More information

ABB 1 NEW. Three-phase monitoring relay for grid feeding CM-UFS.1. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories

ABB 1 NEW. Three-phase monitoring relay for grid feeding CM-UFS.1. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories 2CDC 251 014 F0t09 Features Monitoring of three-phase mains for grid feeding Type-tested in accordance with DIN V VDE V 0126-1-1: February 2006 Neutral conductor connection configurable Can also be used

More information

Power Supplies 3. SDN-P DIN Rail Series

Power Supplies 3. SDN-P DIN Rail Series SDN-P DIN Rail Series The SDN DIN Rail power supplies provide industry leading performance. Sag Immunity, transient suppression and noise tolerant, the SDN series ensures compatibility in demanding applications.

More information

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact Data sheet Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact The CT-AHD.12 is an electronic time relay with OFF-delay. It is from the CT-D range. With their MDRC profile and a width of only

More information

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection) Data sheet Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection) The temperature monitoring relays CM-TCS monitor overtemperature,

More information

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages Data sheet Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages The CM-ESS.2 is an electronic voltage monitoring relay that provides reliable monitoring of voltages as well as detection of

More information

STRATO LED Drivers 70W, Single output

STRATO LED Drivers 70W, Single output Features STRATO switch mode driver technology is designed to generate one constant current output from a wide range AC input. The size and performance of these products make them the ideal choice for LED

More information

ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application.

ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application. 1SR 430 824 F9300 Features Monitoring of three-phase mains for phase sequence and failure Powered by the measuring circuit 2 c/o (SPDT) contacts 1 LED for status indication Approvals R: yellow LED - relay

More information

Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages

Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages Data sheet Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages The CM-ESS.M is an electronic voltage monitoring relay that provides reliable monitoring of voltages as well as detection of

More information

Three-phase monitoring relay CM-PFE

Three-phase monitoring relay CM-PFE Data sheet Three-phase monitoring relay CM-PFE The CM-PFE is a three-phase monitoring relay that monitors the phase parameter phase sequence and phase failure in three-phase mains. 2CDC 251 005 S0012 Characteristics

More information

RM4TG20 three-phase network control relay RM4-T - range 200..500 V

RM4TG20 three-phase network control relay RM4-T - range 200..500 V Characteristics three-phase network control relay RM4-T - range 200..500 V Complementary [Us] rated supply voltage Output contacts Setting accuracy of time delay Delay at power up Measuring cycle Marking

More information

Series AMEPR30-AZ up to 2.5A AC-DC / DC-DC LED Driver / Converter

Series AMEPR30-AZ up to 2.5A AC-DC / DC-DC LED Driver / Converter FEATURES: Click on Series name for product info on aimtec.com Models Single output Model Max Output Power (W) 1 AC-DC Constant Current or Constant Over temperature protection Voltage LED Driver Over current

More information

EPL225 Series. 225 Watts. www.xppower.com. AC-DC Power Supplies. Models & Ratings. Summary

EPL225 Series. 225 Watts. www.xppower.com. AC-DC Power Supplies. Models & Ratings. Summary 225 Watts 50 W Convection/ 225 W Forced-cooled Ratings 2 by 4 Footprint Low.26 Profile 2 V Fan Output High Efficiency, up to 95% ITE & Medical pprovals High Power Density Less than 0.5 W No Load Input

More information

Electronic timer CT-VBS.17+18 OFF-delayed without auxiliary voltage, for DC contactors Data sheet

Electronic timer CT-VBS.17+18 OFF-delayed without auxiliary voltage, for DC contactors Data sheet Characteristics Single-function OFF-delay timer for DC contactors, without auxiliary voltage Width.5 mm CDC 5 6 F3 Approvals A culus E CCC CT-VBS a Circuit diagram b Marker label Marks a CE b C-Tick Order

More information

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC - 0.5 A - M8 connector

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC - 0.5 A - M8 connector Product datasheet Characteristics TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC - 0.5 A - M8 connector Main Range of product Product or component type Range compatibility Enclosure material Bus

More information

Chrome DIN Rail Power Supply 24V 91.2W 1 Phase (Class II & NEC Class 2) / DRC-24V100W1AZ

Chrome DIN Rail Power Supply 24V 91.2W 1 Phase (Class II & NEC Class 2) / DRC-24V100W1AZ Highlights & Features Protection Class II, Double Isolation (No Earth connection is required) Universal AC input voltage without power de-rating Efficiency > 87.0% @ 115Vac, > 89.0% @ 230Vac NEC Class

More information

Type: EASY719 DC RC Article No.: 274119. Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

Type: EASY719 DC RC Article No.: 274119. Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description Type: EASY719 DC RC Article.: 274119 Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC Description 12 digital inputs (4 inputs available as analog inputs) 6 relay outputs LCD display

More information

Analog signal converters CC-E I/I Current / current isolators

Analog signal converters CC-E I/I Current / current isolators ata sheet Analog signal converters CC-E I/I Current / current isolators The CC-E I/I is an isolator for the electrical isolation of current signals without auxiliary supply. It allows the isolation between

More information

Chrome DIN Rail Power Supply 24V 30W 1 Phase (Class II & NEC Class 2) / DRC-24V30W1AZ

Chrome DIN Rail Power Supply 24V 30W 1 Phase (Class II & NEC Class 2) / DRC-24V30W1AZ Highlights & Features Protection Class II, Double Isolation (No Earth connection is required) Universal AC input voltage without power de-rating Efficiency > 87.0% @ 115Vac & 230Vac NEC Class 2 / Limited

More information

Bulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller

Bulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller Overview/Modes of Operation Bulletin 150 Smart Motor Controller The SMC-3 is a compact, simple to use, solid-state motor controller designed to operate 3-phase motors. It features a built-in overload relay

More information

Chrome DIN Rail Power Supply 12V 54W 1 Phase (Class II & NEC Class 2) / DRC-12V60W1AG

Chrome DIN Rail Power Supply 12V 54W 1 Phase (Class II & NEC Class 2) / DRC-12V60W1AG Highlights & Features Protection Class II, Double Isolation (No Earth connection is required) Universal AC input voltage and full power up to 55 C Power will not de-rate for the entire input voltage range

More information

MICROSENS. Central 48 V DC Power Supplies for PoE-Components. Description. Features

MICROSENS. Central 48 V DC Power Supplies for PoE-Components. Description. Features Central 48 V DC Power Supplies for PoE-Components MICROSENS Description Active network equipment which is supporting the Power-over-Ethernet functions, typically requires a powerful 48 V DC power supply.

More information

38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A

38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A 38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A 38 SERIES Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit EMR Electromechanical

More information

Safety technique. Emergency stop module BO 5988 safemaster

Safety technique. Emergency stop module BO 5988 safemaster Safety technique Emergency stop module BO 5988 safemaster 0221562 Function diagram Pushbutton on Mains or emergencystop () K1 According to EC Directive for machines 98/37/EG According to IEC/E 60204-1

More information

Three-phase monitoring relays CM-PSS CM-PSS.31 and CM-PSS.41

Three-phase monitoring relays CM-PSS CM-PSS.31 and CM-PSS.41 Data sheet Three-phase monitoring relays CM-PSS CM-PSS.31 and CM-PSS.41 The three-phase monitoring relays CM-PSS.x1 monitor the phase parameters phase sequence, phase failure as well as over- and undervoltage.

More information

Power Supply, Primary Switch Mode, Narrow Design MINI-PS-100-240AC/2x15DC/1

Power Supply, Primary Switch Mode, Narrow Design MINI-PS-100-240AC/2x15DC/1 Power Supply, Primary Switch Mode, Narrow Design -PS-100-240AC/2x15DC/1 POWER provides: Extra narrow widths of 22.5 and 45 mm (0.886 and 1.772 in.) Global use due to a wide range input A high level of

More information

Redundancy Module QUINT-DIODE/40

Redundancy Module QUINT-DIODE/40 Redundancy Module QUT DIODE provides: 00% decoupling of power supplies connected in parallel Can be installed in potentially explosive areas Load currents up to 60 A supported Easy assembly by snapping

More information

Thermistor motor protection

Thermistor motor protection Thermistor motor protection CM-E Range Thermistor motor protection Thermistor motor protection relays Benefits and advantages Selection table Operating principle and fields of application for thermistor

More information

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages Data sheet Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages The CM-ESS.2 is an electronic voltage monitoring relay that provides reliable monitoring of voltages as well as detection of

More information

Power Supply, Primary Switch Mode, Narrow Design MINI-PS-100-240AC/24DC/2

Power Supply, Primary Switch Mode, Narrow Design MINI-PS-100-240AC/24DC/2 Power Supply, Primary Switch Mode, Narrow Design -PS-100-240AC/24/2 POWER provides: Extra narrow widths of 22.5 and 45 mm (0.886 and 1.772 in.) Global use due to a wide range input A high level of operational

More information

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start 0225592. * see variants. Applications.

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start 0225592. * see variants. Applications. Safety Technique SAFEMASTER Emergency Stop Module BG 5924, IP 5924 Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start 0225592 BG 5924 IP 5924 Product Description

More information

38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 A

38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 A 38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 A Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit EMR Electromechanical Relays

More information

Actuator-Sensor-Interface

Actuator-Sensor-Interface Selection and ordering data Design Order No. Price Pack 3RX9 307-0AA00 3RX9 307-1AA00 4FD5 213-0AA10-1A 3RX9 305-1AA00 3RX9 306-1AA00 Single output IP 65 current 2.4 A Rated input voltage DC 24 V current

More information

PHOENIX CONTACT - 01/2007

PHOENIX CONTACT - 01/2007 Uninterruptible power supply INTERFACE Data Sheet 103123_00_en PHOENIX CONTACT - 01/2007 Description Especially compact and easy-to-use, the new MINI-DC-UPS/ 24 DC/2 is a combination of the power supply

More information

Single-phase (220...240 V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable

Single-phase (220...240 V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable Features 70.11 70.31 70.41 Electronic voltage monitoring relays for single and three-phase applications Multifunctional types, providing the flexibility of monitoring Undervoltage, Overvoltage, Window

More information

38 SERIES. Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A. EMR Electromechanical Relays. Common features. SSR Solid State Relays. 6.

38 SERIES. Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A. EMR Electromechanical Relays. Common features. SSR Solid State Relays. 6. 38 Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A 38 Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit 6.2 mm wide EMR - DC, AC or AC/DC

More information

Your automation should be permanently supplied Our compact PROeco power supplies offer that as part of an economical concept Let s connect.

Your automation should be permanently supplied Our compact PROeco power supplies offer that as part of an economical concept Let s connect. Your automation should be permanently supplied Our compact PROeco power supplies offer that as part of an economical concept Let s connect. Power supply Find the cost-effective solution for your power

More information

CompactLogix Power Supplies Specifications

CompactLogix Power Supplies Specifications Technical Data CompactLogix Power Supplies Specifications 1768 CompactLogix Power Supplies Catalog Numbers 1768-PA3, 1768-PB3 1769 Compact I/O Power Supplies Catalog Numbers 1769-PA2, 1769-PB2, 1769-PA4,

More information

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER Application : The RISH CON - Hz transducer is used for frequency measurement. The output signal is proportional to measured frequency and is either load independent DC Current or load independent DC Voltage.

More information

Telephone- and leased line modem for industrial applications TD-36

Telephone- and leased line modem for industrial applications TD-36 Telephone- and leased line modem for industrial applications TD-36 Modem for industrial PSTN- and leased line applications The TD-36 is an analogue V.34 PSTN modem as well as an industrial 2-wire leased

More information

Thermistor motor protection relays CM-MSS.22 and CM-MSS.23

Thermistor motor protection relays CM-MSS.22 and CM-MSS.23 Data sheet Thermistor motor protection relays CM-MSS.22 and CM-MSS.23 The thermistor motor protection relays CM-MSS.22 and CM-MSS.23 monitor the winding temperature of motors and protect them from overheating,

More information

Electronic overload relay EF19 and EF45

Electronic overload relay EF19 and EF45 Data sheet Electronic overload relay EF19 and EF45 Electronic overload relays offer reliable protection in case of overload and phase-failure. They are the alternative to thermal overload relays. Motor

More information

AC/DC Power Modules C B. TML Series, 20 & 40 Watt. Features. 20 Watt Models

AC/DC Power Modules C B. TML Series, 20 & 40 Watt. Features. 20 Watt Models TML Series, 0 & 0 Watt Features C B Scheme LVD UL 090- Encapsulated power supplies with increased power density Replaces TML and TML 0 series PCB mount or chassis mount with screw terminals Single, dual

More information

MCR-VDC-UI-B-DC. Voltage Transducer for DC Voltages. INTERFACE Data Sheet 100260_en_01. 1 Description

MCR-VDC-UI-B-DC. Voltage Transducer for DC Voltages. INTERFACE Data Sheet 100260_en_01. 1 Description Voltage Transducer for DC Voltages TERFACE Data Sheet 000_en_0 PHOENIX CONTACT - /00 Description The MCR voltage transducer measures DC voltages in several signal ranges from 0... ±0 V DC to 0... ±0 V

More information

CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE. General purpose single phase thyristors and solid state relays Product data.

CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE. General purpose single phase thyristors and solid state relays Product data. 425 CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE General purpose single phase thyristors and solid state relays Product data abc 425 EUROCUBE A complete range of low cost solid state relays and

More information

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw 4 937 DESIO Current valve for AC 24 V pulse/pause control of electrical loads up to 30 kw SEA45.1 Use The current valve is used for the control of electric heating elements in heating, ventilation and

More information

TEP 200WIR Series, 180 240 Watt

TEP 200WIR Series, 180 240 Watt TEP 200WIR Series, 180 240 Watt Features Chassis mount with screw terminal block Including EMI filter to meet EN 55022, class A Ultra wide 4:1 input voltage ranges 8.5 36, 16.5 75, 43 160 VDC EN 50155

More information

Rack mounted telephone- and leased line modem for industrial applications

Rack mounted telephone- and leased line modem for industrial applications Rack mounted telephone- and leased line modem for industrial applications TR-6 Rack modem for industrial PSTNand /-wire leased line applications The TR-6 is an analogue V. 9 -rack PSTN modem as well as

More information

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs E031026 000823 Process modules Digital input PMI for inputs for 120 V AC inputs PMI Input E4, E5, GND L- PMI 120 V AC Input E4, E5, Common C E6, E7, GND L- E6, E7, Common C LEDs for the inputs operation

More information

Electronic overload relay EF65, EF96 and EF146

Electronic overload relay EF65, EF96 and EF146 Data sheet Electronic overload relay EF65, EF96 and EF146 Electronic overload relays offer reliable protection in case of overload and phase-failure. They are the alternative to thermal overload relays.

More information

Product and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information.

Product and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information. Product and Applications Description The power supply units N 125/x2 can supply DC 24 V power from an additional pair of terminals (yellowwhite). This DC 24 V output voltage can be used to power e.g. an

More information

is then retained absolutely without interruption.

is then retained absolutely without interruption. Page 1 of 11 DC UPS uninterruptible power supplies - DC UPS module 15 A Compact design, only 50 mm wide Absolutely interruption-free buffering of power failures through immediate electronic connection

More information

48 SERIES Relay interface modules 10 A

48 SERIES Relay interface modules 10 A 48 Relay interface modules 10 A 1 CO relay interface modules, mm wide Ideal interface for PLC and electronic systems Type 48.P3 1 CO 10 A s Type 48.31 1 CO 10 A s AC coils or DC sensitive coils Supply

More information

R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT ... ... Spur 2. Spur 1. Zone 1. Zone 0

R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT ... ... Spur 2. Spur 1. Zone 1. Zone 0 FieldBarrier Features Assembly 8... 12 outputs Ex ia IIC, FISCO and Entity Advanced fault isolation and diagnostics at the spur FieldBarrier in Zone 1/Div. 2 Instruments in Zone 0...1/Div. 1 For FOUNDATION

More information

LOGO!Power. Power supply. LOGO!Power. Overview. Safety instructions. Description, device design, dimension drawing. Mounting/disassembly

LOGO!Power. Power supply. LOGO!Power. Overview. Safety instructions. Description, device design, dimension drawing. Mounting/disassembly Overview Safety instructions 1 Power supply Operating Instructions Description, device design, dimension drawing 2 Mounting/disassembly 3 Mounting position, mounting clearances 4 Installation 5 Technical

More information

Relés e Contatores de Estado Sólido SIRIUS

Relés e Contatores de Estado Sólido SIRIUS Relés e Contatores de Estado Sólido SIRIUS Coletânea de dados técnicos ( product data sheet ) Agosto/212 SSR - 3RF21 22,5 mm Ponto Zero SSR - 3RF2 45 mm Ponto Zero SSR - 3RF22 45 mm Ponto Zero Trifásico

More information

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous Safety relay for monitoring E-STOP pushbuttons. Approvals Unit features Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous 1 auxiliary contact (N/C), instantaneous Safe separation of

More information

400-800. Series OMEGA WATTS POWER SUPPLY AC/DC SINGLE OR MULTIPLE OUTPUT. Flexible modular design. Programmable outputs** Power factor correction***

400-800. Series OMEGA WATTS POWER SUPPLY AC/DC SINGLE OR MULTIPLE OUTPUT. Flexible modular design. Programmable outputs** Power factor correction*** INPUT Input protection Thermal protection Switching frequency internal fuse standard 100KHz Input with PFC : (MML400PFC, MML600, MML800) Input voltage range 85*-264VAC Inrush current (peak) MML400PFC

More information

Cross-beam scanning system to detect slim objects. 100 mm 3.937 in

Cross-beam scanning system to detect slim objects. 100 mm 3.937 in 891 Object Area Sensor General terms and conditions... F-17 Related Information Glossary of terms... P.1359~ Sensor selection guide...p.831~ General precautions... P.1405 PHOTO PHOTO Conforming to EMC

More information

Bimetallic Overload Relay Specifications

Bimetallic Overload Relay Specifications Technical Data Bimetallic Overload Relay Specifications Bulletin Number 193K, 193T1 Topic Page Product Overview 2 Standards compliance and Certifications 2 General Specifications 193K 3 Approximate Dimensions

More information

O WA-120U series IP67. 120W Single Output Switching Power Supply. Features. Aplications

O WA-120U series IP67. 120W Single Output Switching Power Supply. Features. Aplications Features UniversalACinput/Fulrange Built-inactivePFCfunction Higheficiencyupto91% Protections:Shortcircuit/Overcurent/ Overvoltage/Overtemperature Fanlesdesign,colingbyfreairconvection Colingbyfreairconvection

More information

CliQ DIN Rail Power Supply 24V 120W 1 Phase / DRP024V120W1AA

CliQ DIN Rail Power Supply 24V 120W 1 Phase / DRP024V120W1AA Highlights & Features Reliable design, with expected life of 10 years Compact, rugged design for ease of handling and installation Multiple connections to terminals allowed Designed for Class I Div. 2

More information

7.5 Watt AC-DC Switch Power Supply

7.5 Watt AC-DC Switch Power Supply MAIN FEATURES: 7.5W Small Compact Size PCB Mount Single Output Regulated Output Range : 3.3VDC 24VDC Input Range : 85VAC 265VAC/47 63Hz Or 120VDC 370VDC Very Low Standby Power Consumption < 0.15W Better

More information

Manual motor starter MS116

Manual motor starter MS116 Data sheet Manual motor starter MS116 Manual motor starters are electromechanical devices for motor and circuit protection. These devices offer local motor disconnect means, manual ON/ OFF control, and

More information

EMR measuring and monitoring relays

EMR measuring and monitoring relays EMR and monitoring relays The power of fusion. 1874 1886 1893 1899 1906 1908 1911 1934 1962 1963 1967 1976 1977 1983 1984 1989 1999 There s a certain energy at Eaton. It s the power of uniting some of

More information

Power Meter Series 700

Power Meter Series 700 PowerLogic power-monitoring units Power Meter Series 700 Technical data sheet 2007 Functions and characteristics E90463 The PowerLogic Power Meter Series 700 offers all the measurement capabilities required

More information

Specification guide no. 9 Active harmonic conditioner from 20 to 480 A

Specification guide no. 9 Active harmonic conditioner from 20 to 480 A Active harmonic conditioner from 20 to 480 A Contents 1 - Installations concerned... 2 1.1 - New installations... 2 1.2 - Existing installations... 2 2 - General... 2 2.1 - Scope... 2 2.2 - Applicable

More information

Technical catalogue. Modular DIN rail components Installation contactors

Technical catalogue. Modular DIN rail components Installation contactors Technical catalogue Modular DIN rail components Installation contactors Installation Contactors Overview... ESB Installation Contactors 0 A / AC-/AC-7a ESB0...4 4 A / AC-/AC-7a ESB4...5 40 A / AC-/AC-7a

More information

ST Series POWER SUPPLIES USER INSTRUCTIONS

ST Series POWER SUPPLIES USER INSTRUCTIONS Introduction These instructions detail the installation and operation requirements for the ST20 & ST35 power supplies. These have been designed for operation in RV s providing a DC power system, with optional

More information

SURGE PROTECTIVE DEVICES

SURGE PROTECTIVE DEVICES SURGE PROTECTIVE DEVICES 1. INTRODUCTION In order to ensure safety of people, protection of equipment and, to a certain extent, continuity of supply, insulation co-ordination aims at reducing the likelihood

More information

48.12. 2 pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2,000 500 0.37 8/0.65/0.

48.12. 2 pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2,000 500 0.37 8/0.65/0. 48 Series - Relay interface modules 8 A Features 48.12 2 Pole Safety relay interface modules, 15.8 mm wide 48.12-2 Pole 8 A (screw terminal) DC sensitive coils Relay with forcibly guided contacts according

More information

AC-DC Single Output Power Module

AC-DC Single Output Power Module AC-DC Single Output Power Module PFHC (AC-DC Conversion) and DC-DC Conversion Integrated in One Package. 2-in-1 Design Concept One module now contains the functions previously only obtainable by combining

More information

APD336.221/.421 3 Outputs 19" DC/DC Converter, 50 Watt

APD336.221/.421 3 Outputs 19 DC/DC Converter, 50 Watt APD336.221/.421 3 Outputs 19" DC/DC Converter, 50 Watt High efficiency: 79% (@ 48V) DCin wide range: 9...36V or 18...72V DC 8 HP plug in width H15 standard pinout Active inrush current suppression Voltage

More information

Thyristor-controlled power supplies and battery chargers

Thyristor-controlled power supplies and battery chargers Thyristor-controlled power supplies and battery chargers Input voltage: 115 / 230 VAC, single phase, 50 / 60 Hz or 208 / 400 / 480 VAC, three phases, 50 / 60 Hz Output voltage: 12 / 24 / 48 / 60 / 72 /

More information

650W Single Output Power Supply

650W Single Output Power Supply AK-650 series Features : Universal AC input with active PFC Programmable output Voltage ( 0% ~ 05% ) Programmable output Current ( % ~ 05% ) High efficiency up to 9% + / 0.5A auxiliary output Intelligent

More information

Mini Circuit Breakers, Fuse Blocks, and Electronic Circuit Protection

Mini Circuit Breakers, Fuse Blocks, and Electronic Circuit Protection Technical Data Mini Circuit Breakers, Fuse Blocks, and Electronic Circuit Protection Topic Page 1489-M Miniature Circuit Breakers 2 1492-SP Supplementary Protectors 15 1492-D Circuit Breakers 27 188 Regional

More information

NFF Series. CoolX600 NFF Series Cool. Patented Resonant Technology. NFF Series; No Fan Featured

NFF Series. CoolX600 NFF Series Cool. Patented Resonant Technology. NFF Series; No Fan Featured Cool TM 600 NFF Series Patented Resonant Technology NFF Series; No Fan Featured 100% natural convection cooled No internal or external fans needed No base-plate needed No Acoustic Noise or Vibrations &

More information

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features: Application : RISH Master 3490 DS measures important electrical parameters of Utility (in normal mode) & Generators (in Power back up) in three phase and single phase Network & replaces the multiple analog

More information

MINI MCR-SL-R-UI(-SP)

MINI MCR-SL-R-UI(-SP) Resistance/potiposition transducer INTERFACE Data Sheet 0807_en_05 Description PHOENIX CONTACT - 0/008 Features The slim MINI MCR-SL-R-UI... potiposition transducer has a width of only 6. mm and converts

More information

CliQ DIN Rail Power Supply 24V 120W 1 Phase / DRP024V120W1AA

CliQ DIN Rail Power Supply 24V 120W 1 Phase / DRP024V120W1AA Highlights & Features Universal AC input voltage Power will not de-rate for the entire input voltage range Power Boost of 150% for 3 seconds Full corrosion resistant aluminium chassis SEMI F47 certified

More information

Safety automation solutions

Safety automation solutions Operating principle, characteristics Preventa safety s types XPS AV,, For and switch monitoring Operating principle Safety s XPS AV, and are used for monitoring circuits conforming to standards EN/ISO

More information

49 Series - Relay interface modules 8-10 - 16 A. Features

49 Series - Relay interface modules 8-10 - 16 A. Features Features 1 & 2 Pole relay interface modules 5 µm Gold plate contacts for low level switching capability 49.31-50x0-1 Pole 10 A (screw terminal) 49.52-50x0-2 Pole 8 A (screw terminal) 49.72-50x0-2 Pole

More information

Multifunctional three-phase monitoring relays CM-MPS CM-MPS.43

Multifunctional three-phase monitoring relays CM-MPS CM-MPS.43 Data sheet Multifunctional three-phase monitoring relays CM-MPS CM-MPS.43 The three-phase monitoring relay CM-MPS.43 monitors the phase parameters phase sequence, phase failure, over- and undervoltage

More information

H/L = Power supply. FN = Nominal Frequency. RN = Rated value of output burden. UN = Nominal input voltage. IN = Nominal input current.

H/L = Power supply. FN = Nominal Frequency. RN = Rated value of output burden. UN = Nominal input voltage. IN = Nominal input current. Application : The transducer RISH CON - CA/CV (Fig.1) converts a sinusoidal AC Current or AC Voltage into a load independent DC Current or a load independent DC Voltage proportional to the measured value.

More information

SITOP power supply. Technical data. SITOP Power Supply. Answers for industry.

SITOP power supply. Technical data. SITOP Power Supply. Answers for industry. SITOP power supply Technical data SITOP Power Supply Answers for industry. Selection table SITOP power supplies Input voltage Output current modular smart LOGO!Power Special design, SIMATIC design Others

More information

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application 33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application Features Compliant with the IEEE802.3at Standard -40 to +60 C Temperature Range Diagnostic LEDs Full Protection

More information

MILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS)

MILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS) MILLENIUM Table of contents 1. INTRODUCTION 1 2. HARDWARE DESCRIPTION 2 3. INSTALLATION 5 4. CONNECTION 6 5. USER SAFETY AND PROTECTION OF EQUIPMENT 8 1. Introduction The MILLENIUM series has been designed

More information

Bulletin 150 SMC Flex Smart Motor Controller Specifications

Bulletin 150 SMC Flex Smart Motor Controller Specifications Specifications Specifications Standard Features Optional Features Installation Setup Communications Power Wiring Control Wiring Keypad Software Starting and Stopping Modes Protection and Diagnostics Metering

More information

Antec TruePower User's Manual

Antec TruePower User's Manual User s Manual Antec TruePower User's Manual Antec TruePower ATX12V power supply Models: TRUE330, TRUE380, TRUE430, TRUE480, TRUE550 Antec Low Noise Technology: The Antec TruePower power supply is equipped

More information

ELECTRONIC POWER SYSTEMS

ELECTRONIC POWER SYSTEMS ELECTRONIC POWER SYSTEMS TRADEOFFS BETWEEN SINGLE-PHASE & THREE-PHASE POWER WHITE PAPER: TW0057 1 Executive Summary Modern Electronic Systems are quite often powered from a three-phase power source. While

More information

MasterINTERFACE 39 Series - Relay interface modules

MasterINTERFACE 39 Series - Relay interface modules MasterINTERFACE 39 Series - Relay interface modules Common features Space saving 6.2 mm wide Connections for 16-way jumper link Integral coil indication and protection circuit Secure retention and easy

More information

CPCI-3U-AC-300W-R. Rugged 300W AC Input 3U CompactPCI Power Supply. Electrical Specification for: Telkoor Part Number: 900-4602-0000

CPCI-3U-AC-300W-R. Rugged 300W AC Input 3U CompactPCI Power Supply. Electrical Specification for: Telkoor Part Number: 900-4602-0000 Electrical Specification for: CPCI-3U-AC-300W-R Rugged 300W AC Input 3U CompactPCI Power Supply Telkoor Part Number: 900-4602-0000 GENERAL SCALE RELEASE DATE 12/9/06 SHEET 1 OF 6 REVISION HISTORY Rev Level

More information

Power Supplies 3. SDN-C Compact DIN Rail Series

Power Supplies 3. SDN-C Compact DIN Rail Series Power Supplies 3 SDN-C Compact DIN Rail Series The SDN-C DIN rail power supplies are the next generation of the popular SDN series. These models combine high efficiency and compact size with new visual

More information

Easy Multifunctional Safe

Easy Multifunctional Safe EMS Electronic motor starters www.eaton.eu Easy Multifunctional Safe EMS Multifaceted Performance with only 0 mm Eaton Moeller series products have always embodied quality and reliability in the machine

More information

APC Matrix-UPS 5kVA 208V/240V In 120/208/240V Out

APC Matrix-UPS 5kVA 208V/240V In 120/208/240V Out APC Matrix-UPS 5kVA 208V/240V In 120/208/240V Out APC Matrix-UPS, 3750 Watts / 5000 VA,Input 208V / Output 120V, 208V, Interface Port DB-9 RS-232, SmartSlot, Extended runtime model Includes: CD with software,

More information

AF09-30-22-.. / AF09Z-30-22-.. 2-stack 3-pole Contactors AC / DC Operated - with Screw Terminals

AF09-30-22-.. / AF09Z-30-22-.. 2-stack 3-pole Contactors AC / DC Operated - with Screw Terminals Technical Datasheet 1SBC101403D0201 24/03/11 AF09-30-22-.. / AF09Z-30-22-.. 2-stack 3-pole Contactors AC / DC Operated - with Screw Terminals AF09(Z) contactors are used for controlling power circuits

More information