Rapid and safe. DAC UNIVERSAL CLEANS, LUBRICATES AND STERILIZES INTERNALLY ROTATING INSTRUMENTS
|
|
|
- Cynthia McDaniel
- 9 years ago
- Views:
Transcription
1 CAD/CAM SYSTEMS INSTRUMENTS HYGIENE SYSTEMS TREATMENT CENTERS IMAGING SYSTEMS DAC UNIVERSAL CLEANS, LUBRICATES AND STERILIZES INTERNALLY ROTATING INSTRUMENTS Rapid and safe. T h e D e n t a l C o m p a n y
2 SIRONA DAC UNIVERSAL Cleaner handpieces and turbines. Get cleaner handpieces and turbines with the DAC UNIVERSAL combination autoclave and save time in the clinic. Cleaning instruments before sterilizing them is essential for successful sterilization. The DAC UNIVERSAL is able to clean the internal channels of the handpieces, contra angles and turbines. During the external wash the instruments are washed twice with cold water (pulse wash) and once with hot water. This process removes biofilm and dirt faster and more effectively. It is normally very diffi cult to clean the channels manually. The DAC UNIVERSAL is able to thoroughly clean the instruments both internally and externally, thereby ensuring that they are optimally prepared for sterilization. Tests have shown that the number of repairs to handpieces, contra angles and turbines is reduced as a result of the fact that dirt is removed from the internal channels in the instruments and thanks to the extremely thorough and consistent maintenance of the instruments. This extends the lifetime of the handpieces, contra angles and turbines. The absence of dirt in the internal channels reduces the amount of repair work resulting from damage caused by dirt inside the instruments. Enjoy every day. With Sirona
3 BACK IN ACTION QUICKLY Cleans, lubricates and sterilizes in approx. 12 minutes. HYGIENIC AND EFFICIENT A minimum of effort giving maximum timesaving. Save time in the clinic Using the DAC UNIVERSAL reduces the time spent cleaning and lubricating the handpieces, contra angles and turbines manually. Moreover, as the DAC UNIVERSAL is a highly efficient autoclave that ensures a fast process, thereby reducing the time spent on cleaning, maintenance and sterilization procedures in the clinic. Lubrication Lubrication is fully automatic using the amount of oil recommended by the manufacturer. When the accessory basket for small dental instruments is used, the oiling process can be manually deactivated. Sterilization The DAC UNIVERSAL has four sterilization processes which the user can choose between. The four programmes are: 134 C, 3-minute sterilization 134 C, 18-minute sterilization 121 C, 15-minute sterilization 134 ºC, wrapped sterilization The basic principle behind each sterilization process in the DAC UNIVERSAL autoclave is the use of a back-flush mechanism. The backflush ensures that the saturated steam is forced through the instruments, thereby sterilizing the internal channels as well as the external parts of the handpieces and turbines. Instead of countless single manual cleaning, expensive lubrication and time-consuming sterilization, simply load your instruments into the combination-autoclave and take them out cleaned, lubricated and sterilized. In comparison to the conventional handling of the instruments, the DAC Universal is clearly more effective and extremely DAC UNIVERSAL time-saving. But not only the total time consumption for hygiene care and maintenance of your instruments is lowered. As cleaning, lubrication and sterilizing is fully automated, the team at the clinic will also be able to concentrate on other tasks. Mounting: 30 sec. Cleaning/Lubricating/Sterilizing: 12 min. Ready: 12:30 min. We recommend that instruments intended for storage or surgery are wrapped and resterilized. Manual Handling Instruments are cleaned, lubricated and sterilized 1 0:00 0:30 Lid closes. 4 0:30 1:20 Leak test. 1:20 2:15 Internal cold cleaning :15 2:30 Lubrication. 2:30 5:00 External cold cleaning. 5:00 5:30 External hot cleaning. 5:30 6:25 Heating procedure to 134 C. 6:25 7:35 Back-Flush. The steam is forced through the open instruments via the valves. 7:35 10:35 Sterilization. 10:35 11:10 Back-Flush. The steam is forced through the open instruments via the valves. 11:10 11:35 Drying. 11:35 11:50 Lid opens a little bit. 11:50 12:00 Lid opens after pressing C. Cleaning: 3 min. Lubricating: 3 min. Sterilizing: min. Ready: min
4 PROPER HYGIENE FOR ALL TYPES OF INSTRUMENTS The extraordinary is our standard. STERILIZE SAFELY Unique design, quality and versatility. The versatility of the DAC UNIVERSAL ensures that you will have both wrapped, unwrapped and solid instruments back in action quickly. Unwrapped instruments The three standard programs of the DAC UNIVERSAL provide you with up to six thoroughly cleaned, lubricated and sterilized hand pieces or turbines in a record time. These instruments are then ready for immediate use. Wrapped instruments With the DAC UNIVERSAL you can also sterilize wrapped instruments. Up to three wrapped instruments will be sterilized in a quick cycle which should be run after and in addition to one of the DAC UNIVERSAL standard programs. This wrapped cycle will enable you to have your wrapped instruments sterilized and back in action very quickly. The wrapped instruments can also be used for surgery or stored for later use. Solid instruments With the additional basket for the DAC UNIVERSAL solid instruments are cleaned and sterilized quickly without any manual handling. This eliminates the risk of human errors and protects the clinic staff from possible injuries from cuts, etc. Unique design and quality are essential for the production which is certified according to the ISO 9001:2000 and ISO 13485:2003 standards by Lloyd s Register Quality Assurance. The HygCen Centrum GmbH has tested the performance of the DAC UNIVERSAL combin ation autoclave according to the European standard EN as a class S type certificated for sterilization of handpieces and contra angles. The DAC UNIVERSAL carries the CE mark. The DAC UNIVERSAL is a low-noise autoclave. Safety User safety is a primary concern for Sirona Dental Systems. The DAC UNIVERSAL combination autoclave features a safety ring that prevents the user s fingers from being caught between the chamber and the lid. In addition, it must be stressed that the lubrication process is carried out in a closed system. This prevents the release of oil fumes into the clinic during the lubrication process. A built-in water conductivity sensor measures the water quality and activates an alarm if the water quality in the tank deteriorates. Servicing the DAC UNIVERSAL combination autoclave is extremely straightforward, making it eas ier, faster and cheaper to service the machine. Reports It is possible to connect a printer or data logger (accessories) to the DAC UNIVERSAL. Connecting either of these to the DAC UNIVERSAL will produce a transcript of the latest sterilization cycle. The information from this transcript includes time, temperature, pressure and the serial number of the DAC UNIVERSAL, and a conclusion on the sterilization cycle whether it was successful or unsuccessful. Specifications Voltage Power consumption Water quality Water tank capacity Oil tank capacity Height open Height closed Width Depth Installation DAC UNIVERSAL The DAC UNIVERSAL is a multiple-voltage machine, which means that it can operate at any voltage level between V, 50/60 Hz 1.1 kw Demineralised or distilled water (< 3 µs) 2.0 l 0.2 l 60 cm 35 cm 36 cm 37 cm The following installations are necessary: Pressurized air (there is a pressure regulator built into the machine) The instruments are lubricated in a closed system which prevents the release of oil fumes into the clinic during the lubrication process
5 PERSONAL EXPERIENCES DAC UNIVERSAL recommended around the world. WATER TREATMENT SYSTEM NITRADEM DIRECT CONNECT Aabyhoej, Denmark Dentist Ole Steffensen The DAC is an extremely effective autoclave, which can handle the complete process for turbines and contra angles between each patient due to the short cycle time. Madrid, Spain Dentist Fernando Luengo Since we bought the DAC in April of 2004 we have experienced a much longer lifespan of our instruments, which has led to great money saving in repairs. Furthermore the DAC has saved us time with the all in one procedure and we find it one of the best acquisitions made. Direct Connection NitraDem Direct Connect provides high quality demineralised water directly to your DAC UNIVERSAL and any other autoclave. This highly efficient water treatment system is fully automated and furthermore conforms to the European Norm EN1717, which allows the direct connection between water system and autoclave. The capacity of the NitraDem Direct Connect is so large that it can supply up to three autoclaves at the same time. NitraDem Direct Connect also gives you the possibility to tap demineralised water if needed. Easy handling With the NitraDem Direct Connect you no longer have to worry about the handling of heavy water bottles. Moreover, the extremely easy handling of the water treatment system means that you can focus on other important tasks in the busy day-to-day activities in the clinic. The NitraDem Filter demineralises water using an ion exchange system and the filter itself is very easy and quick to change. Passau, Germany Dr. med. dent. Rolf Linseisen The DAC Universal plays a fundamental part in securing optimal hygiene procedures in our modern clinic and at the same time it ensures total process safety. Guernsey, Great Britain Dentist Gareth Wallis We bought a DAC Universal in August 2005 and instantly felt that it is very easy to use. We especially appreciate that the assistants now have more time left to help the dentists and for other tasks. Constant monitoring To ensure the best working conditions for your DAC UNIVERSAL and other autoclaves, NitraDem Direct Connect constantly monitors the quality of the demineralised water. This constant flow of demineralised water with a minimum microsiemens level prolongs the lifespan of your autoclaves and lowers their repair costs. Béziers, France Dentist Dr. Christian Bodart The saving of time enables us to release the assistant for other tasks helping at the chair or administrative tasks. My associate and I, we are sure that we have made the best choice for our dental office. Greenhills, Australia Pacific Smiles Dental Pacific Smiles Dental believes that the implementation of the DAC has been a positive addition to our existing high standards of infection control. The DAC is an exceptionally efficient and user-friendly device. The staff of Pacific Smiles Dental Greenhills now wonders how they ever survived without the DAC! Control Panel: REF Hamburg, Germany Dr. med. dent. Axel Posorski Now we are not only saving time by having a machine, which can handle all three processes in one, we also get a better result and more time with the patients. Brescia, Italy Dottori Bazzoli, Mainetti e Treccani Not only have the employees benefited from the DAC Universal but also the patients, as the assistants have got more time for the patients at their disposal. Water pistol: REF Installations kit: REF NitraDem filter: REF
6 REF Extra lid without adapters REF Holder for Lid REF Complete basket For cleaning and sterilization of solid products. REF Replacement basket REF Basket for small parts REF Filter, 6 pcs. REF Cleaning tabs, 100 pcs. REF Chemical indicators, 100 pcs. REF Spore tester To be used for validating the DAC UNIVERSAL combination autoclave. Place the biological or chemical indicator inside the tester. Close the spore-tester and place it on the E-type click adapter for handpieces (REF ). REF Holder for indicator To be used for validating the DAC UNIVERSAL autoclave. Place the biological indicator and/ or the chemical indicator in the clip and place the clip on the lid. REF Printer Printer for the DAC UNIVERSAL. REF Sirona TE adapter Handpiece adapter for TE & T1 classic instruments. To load: Gently click the handpiece onto the adapter without the use of force. To unload: Pull the handpiece off REF Intramatic adapter E-type adapter for handpieces. To load: Click the handpiece onto To unload: Push the small button on the adapter and remove the instrument. REF Adapter for Kavo handpiece heads To load: Place the Kavo head in the adapter hole and press down. To unload: Pull the Kavo head off REF Lid & Steril-Filter for wrapped instruments For wrapped instruments from serial number REF Sirona turbine adapter To load: Click the turbine onto REF Kavo turbine adapter REF W&H turbine adapter To load: Click the turbine onto REF W&H turbine adapter For TA-98LW/96LW high-speed instruments only! REF Bien Air turbine adapter To unload: Push the small button on the adapter and remove the instrument. REF Castellini turbine adapter To load: Click the turbine onto REF NSK Phateleus adapter To load: Click the instrument onto To unload: Pull off the instrument. REF NSK Pana QD adapter To load: Click the turbine onto REF NITRAM OIL 200 ml (white), 6 pcs. Lubrication for use in the DAC UNIVERSAL with serial No. < REF NITRAM OIL #2 200 ml (blue), 6 pcs. Lubrication for use in the DAC UNI- VERSAL with serial No REF Midwest adapter for quick connect (4, 5, 6 holes) To load: Align the instrument to fit the holes and press down. To unload: Press the ring and pull off the instrument. REF Midwest adapter for fixed back-end (4, 5, 6 holes) To load: Align the Midwest instrument on the adapter to fit the holes, then turn and fasten the threaded part on To unload: Turn and loosen the threaded part of the adapter and remove the instrument. REF Midwest XGT/Stylus turbine adapter To unload: Push the small button on the adapter and remove the instrument. REF Star swivel adapter To load: Turn the basic plate of the adapter to the right and click the turbine onto To unload: Turn the basic plate of the adapter to the right and pull the turbine off REF Adapter for Star attachment To load/unload: Place/remove the coupling the same way that the coupling is normally placed/ removed on the Star motor. REF Adapter for Morita turbines (PAR-DI) To attach: snap the turbine into To detach: Press the small button on the adapter and detach the instrument. REF Morita (PAR-O) turbine adapter To load: press the turbine onto To unload: Push the small button on the adapter and remove the instrument. REF Adapter for Yoshida turbines To attach: Press the button and snap the turbine into To detach: Press the button on the adapter and detach the turbine. REF OSADA OFJ-MZL To attach: Snap the turbine into To detach: Press the bottom plate on the adapter and detach the turbine
7 CAD/CAM SYSTEMS INSTRUMENTS HYGIENE SYSTEMS TREATMENT CENTERS IMAGING SYSTEMS SIRONA UNIQUE WORLDWIDE SYSTEMS EXPERTISE IN DENTAL EQUIPMENT PRODUCTS Sirona develops and manufactures a comprehensive range of dental equipment, including CAD/CAM Systems for dental practices (CEREC) and laboratories (inlab), Instruments and Hygiene Systems, Treatment Centers and Imaging Systems. Sirona manufactures high technology products that guarantee ease of use and a high return on investment for the good of your practice and for the benefit of your patients. In this way, you can approach every challenge you face with confidence. Enjoy every day. With Sirona. Subject to technical changes and errors in the text, Order No. A91100-M45-A , Printed in Germany, Dispo No , 4023/14058 WS V2 Sirona Dental Systems [email protected] T h e D e n t a l C o m p a n y
We make a point of ensuring safety.
CAD/CAM SYSTEMS INSTRUMENTES HYGIENE SYSTEMS TREATMENT CENTERS IMAGING SYSTEMS INSTRUMENTS FOR EFFICIENT ROOT CANAL TREATMENT We make a point of ensuring safety. T h e D e n t a l C o m p a n y ENDODONTIC
MELA quick 12+ Compact. Fast. Strong.
MELA quick 12+ Compact. Fast. Strong. The requirement. Requirements for the preparation of dental instruments are defined by official hygiene experts. Instruments for semicritical use (restorative treatment)
A new wave in instrument washing and disinfection Introducing the new HYDRIM G4 WD series
A new wave in instrument washing and disinfection Introducing the new HYDRIM G4 WD series Taking control of your infection control The hazards of manual cleaning Hand scrubbing is increasingly used less
Just one click gives you more class.
CAD/CAM SYSTEMS INSTRUMENTS HYGIENE SYSTEMS TREATMENT CENTERS IMAGING SYSTEMS T1, T2, T3 HIGH-SPEED HANDPIECES TO SUIT EACH INDIVIDUAL DEMAND Just one click gives you more class. T h e D e n t a l C o
ETD3 the new standard in endoscope reprocessing.
Endoscope Reprocessing ETD3 Automatic Endoscope Reprocessor ETD3 the new standard in endoscope reprocessing. 2 The standard in endoscope reprocessing: The Olympus ETD3. The Olympus ETD system has become
Systematic X-ray diagnostics as flexible and individual as your dental practice.
CAD/CAM SYSTEMS INSTRUMENTS HYGIENE SYSTEMS TREATMENT CENTERS IMAGING SYSTEMS XIOS PLUS THE INTRAORAL SENSOR SYSTEM Systematic X-ray diagnostics as flexible and individual as your dental practice. T h
Totally lightweight, totally flexible, totally titanium.
CAD/CAM SYSTEMS INSTRUMENTS HYGIENE SYSTEMS TREATMENT CENTERS IMAGING SYSTEMS CAD/CAM SYSTEMS INSTRUMENTS HYGIENE SYSTEMS TREATMENT CENTERS IMAGING SYSTEMS SIRONA UNIQUE WORLDWIDE SYSTEMS EXPERTISE IN
STATIM G4 Cassette Autoclaves From start to dry in the blink of an eye.
STATIM G4 Cassette Autoclaves From start to dry in the blink of an eye. STATIM, the world s fastest autoclave from start to sterile Drawing on over 20 years of innovation, Healthcare practitioners in over
AUTOCLAVE STEAM STERILIZERS
AUTOCLAVE STEAM STERILIZERS (BENCH TOP) Image: HS-1606VD Hanshin Bench Top Steam Sterilizer Small and easy to operate Three preset sterilization cycles Adjustable cycle presets Rapid heat up times Option
LABOKLAV. Autoclaves Made in Germany. www.shp-steriltechnik.de
LABOKLAV Autoclaves Made in Germany www.shp-steriltechnik.de 2 LABOKLAV STEAM STERILIZERS Steam sterilization is the sterilization method with the widest range of applications efficient, safe, reproducible
one claim: only the best into your hands.
Always at THE Forefront of Innovation! As global innovation leader for dental equipment, we continuously invest in re search and thus in the future of modern dentistry. By networking digital technologies
Clinic Washer-Disinfectors. Washer-Disinfector Line
Clinic Washer-Disinfectors Washer-Disinfector Line Easy-to-Use Washer-Disinfectors for Clinics The Clinic Range of Washer Disinfectors provides superior cleaning and disinfection combined with innovative
Totally lightweight, totally flexible, totally titanium.
CAD/CAM SYSTEMS INSTRUMENTS HYGIENE SYSTEMS TREATMENT CENTERS IMAGING SYSTEMS T1 LINE THE LIGHTWEIGHT TITANIUM INSTRUMENTS Totally lightweight, totally flexible, totally titanium. T h e D e n t a l C o
clean and quiet dental
clean and quiet dental clean air for your dental clinic JUN-AIR introduced the first compressor almost 50 years ago and started the development of the technology and design, which has made JUN-AIR compressors
Material test chamber with mechanical convection
FP series 400 Material test chambers Material test chamber with mechanical convection A BINDER material test chamber with mechanical convection of the FP series provides reliably short drying times and
SunMaxx Solar Filling Station Operating Instructions
SunMaxx Solar Filling Operating Instructions Content 1. Declaration of conformity... 2 2. Introduction... 2 3. Transportation and unpacking... 4 4. Mounting and commissioning... 5 5. End of operation...
OT 40L / 90L. Laboratory Steam Sterilizers
OT 40L / 90L Laboratory Steam Sterilizers OT 40L / 90L LABORATORY STEAM STERILIZERS OT 40L / OT 90L laboratory steam sterilizers are specially designed for the steam sterilization of liquid and culture
The professional for your diagnostics.
CAD/CAM SYSTEMS INSTRUMENTS HYGIENE SYSTEMS TREATMENT CENTERS IMAGING SYSTEMS DIGITAL PANORAMIC X-RAY MADE SIMPLE The professional for your diagnostics. System concept ORTHOPHOS XG 5 completes the next
Model Voltage (V/Hz) Power (W) Capacity (L) Chamber size Outside size(mm) Weight (kg) STE-TEN 220/50 1100 1 Ø90x160mm W200xH385xD450 30 (Net:28)
Table Top STE-TEN STE-TEN, 1 Liter Autoclave It adopts B-wclass (pred-13060), with 3-times pre-vacuum preceding vacuum drying. Residual humidity is 0.2, vacuum measurement reaches -0.7bar. It sterilizes
Portable Compressors MOBILAIR M122 With the world-renowned SIGMA PROFILE Free air delivery 11.1 m³/min. www.kaeser.com
Portable Compressors MOBILAIR M122 With the world-renowned SIGMA PROFILE Free air delivery 11.1 m³/min www.kaeser.com Made in Germany KAESER s renowned MOBILAIR range of portable compressors is manufactured
Sterilizers with extra class
Sterilizers with extra class ClassB Ready for the future The European standard EN 13060 specifies the performance requirements and test methods for small steam sterilizers. These are used for hygiene and
93052/1115-V05. C260 User Manual
93052/1115-V05 C260 User Manual QUICK GUIDE Preparing waste-holding tank 1 2 3 4 5 6 7 8 9 10 11 12 Preparing flush-water tank (only for C262-models) 13 14 15 16 Preparing Electric Ventilator (if applicable)
C4 + Compact design newly defined.
C4 + Treatment Centers C4 + Compact design newly defined. C4 + The plus for your practice. Sirona is a young company with a long tradition. For more than a century, Sirona has been supplying high-quality
We make a point of ensuring safety.
CAD/CAM SYSTEMS INSTRUMENTS HYGIENE SYSTEMS TREATMENT CENTERS IMAGING SYSTEMS INSTRUMENTS FOR EFFICIENT ROOT CANAL TREATMENT We make a point of ensuring safety. T h e D e n t a l C o m p a n y ENDODONTIC
Tabletop Line. Automatic and Semi-Automatic Autoclave Series
Tabletop Line Automatic and Semi-Automatic Autoclave Series Tuttnauer Your Sterilization & Infection Control Partner Company Profile For over 80 years, Tuttnauer s sterilization and infection control products
NÜVE SANAYİ MALZEMELERİ İMALAT VE TİCARET A.Ş. OT 020 BENCH TOP STEAM STERILIZER USER S MANUAL
NÜVE SANAYİ MALZEMELERİ İMALAT VE TİCARET A.Ş. OT 020 BENCH TOP STEAM STERILIZER USER S MANUAL NÜVE SANAYİ MALZEMELERİ İMALAT VE TİCARET A.Ş. Esenboğa Yolu 22 km Akyurt - ANKARA / TURKEY Tel : (00 90 312)
Cliniklav 25. For highest quality in surgical applications MELAG. Evidence Based Sterilization
Cliniklav 25 For highest quality in surgical applications MELAG Evidence Based Sterilization Cliniklav 25 The big one from MELAG a powerful piece of technology Built-in printer for documenting program
THREE CLASSES, ONE CLAIM: ONLY THE BEST INTO YOUR HANDS.
SIRONA INSTRUMENTS PREMIUM, COMFORT AND ECONOMY THREE CLASSES, ONE CLAIM: ONLY THE BEST INTO YOUR HANDS. SIRONA.COM Made in Germany Titan, the exclusive material As the only manufacturer in the dental
Model Voltage (V/Hz) Power (W) Capacity (L) Chamber size Outside size(mm) Weight (kg) STE-TEN 220/50 1100 1 Ø90x160mm W200xH385xD450 30 (Net:28)
Table Top STE-TEN STE-TEN, 1 Liter Autoclave It adopts B-class (pred-13060), with 3-times pre-vacuum preceding vacuum drying. Residual humidity is 0.2, vacuum measurement reaches -0.7bar. It sterilizes
Hydraulic Control Solutions
Hydraulic Control Solutions Vexve s Hydrox hydraulic control solutions are suitable for even the most challenging installation sites and conditions. Specifically designed for district heating and district
T1 LINE. Handpieces. T1 LINE supreme ergonomics in titanium.
T1 LINE Handpieces T1 LINE supreme ergonomics in titanium. > To be quite frank, flexibility is what I m aiming at in my dental practice. Now the choice is easy: the Sirona T1 LINE handpiece range.< Andrew
The Premium-Plus-Class Now even better
The Premium-Plus-Class Now even better Innovation and quality the philosophy of a family-run business As an owner-run and operated family concern founded in 1951, we have a long history of successful specialization
Systematic X-ray diagnostics as flexible and individual as your dental practice. XIOS PLUS the intraoral sensor system
C A D / C AM SYSTEMS INSTRUMENT S HYGIENE SYSTEMS TRE ATMENT CENTERS IM AGING SYSTEMS XIOS PLUS the intraoral sensor system Systematic X-ray diagnostics as flexible and individual as your dental practice.
Short Form Catalogue. Alarm Systems. Reliable Supervision and Control
Short Form Catalogue Alarm Systems Reliable Supervision and Control Alarm Monitors and Indicators The SELCO product range includes a number of alarm monitors and indicator panels for use in numerous applications.
Convection Ovens. BX Classic. Models BX4 / FG 189C, BX4-6040 / FG 158C, BX10 / FG 180C. Operator's Manual
Convection Ovens BX Classic Models BX4 / FG 189C, BX4-6040 / FG 158C, BX10 / FG 180C Operator's Manual Belshaw Bros., Inc. 814 44 th Street NW, Suite 103 Auburn, WA 98001 USA Phone: 206-322-5474 Fax: 206-322-5425
FVA/A1 saturated-steam sterilizer
FVA/A1 where technology innovation and design come together FVA/A1 saturated-steam sterilizer www.fedegariautoklaven.ch Fedegari's new FVA/A1 series of automatic vertical sterilizers has been expressly
Bench Autoclave. Standard Operating Procedure. For Installation, Use and Maintenance
Bench Autoclave Standard Operating Procedure For Installation, Use and Maintenance 1. Introduction This SOP is intended for use with the following model, in a laboratory context: Type: Nuve Bench Top Steam
FTDI VCP DRIVER (free) (WIN/MAC/LINUX) http://www.ftdichip.com/drivers/vcp.htm
002 - CONNECTING THE PRINTER Now that you have an idea what 3D printing entails, we can continue and connect the printer to your computer. First make sure you have a computer with a decent amount of RAM
Integra Padgett. Dermatomes. Limit uncertainty with quality and power from the brand you trust
Integra Padgett Limit uncertainty with quality and power from the brand you trust Integra Padgett Electric Slimline Dermatome Models S and S6 The Integra Padgett Electric Slimline Dermatome Models S and
Supplies 1. Toner cartridges. Printing. Using color. Paper handling. Maintenance. Troubleshooting. Administration. Index
Toner cartridges Supplies 1 Warning: Do not touch the cartridge roller located under the cover. Cover Your printer uses four separate toner cartridges, one for each color: cyan, yellow, magenta, and black.
INTEGO. PERFORMANCE YOU CAN RELY ON.
INTEGO. PERFORMANCE YOU CAN RELY ON. 1 CAMPAIGN CLIP 2 INTEGO: THE RIGHT ANSWER TO CUSTOMER NEEDS 3 TWO TREATMENT CONCEPTS CS WITH WHIP ARMS TS WITH HANGING HOSES INTEGO pro TWO PRODUCT VERSIONS INDIVIDUAL
Heating oven with mechanical convection
FD series 53 Drying ovens / Heating ovens Heating oven with mechanical convection A BINDER FD series heating oven is always used when fast drying and sterilization is required. Thanks to its fully homogeneous
Laboratory Autoclave SN210/310/510,SQ510/810
1/5 Laboratory Autoclave SN210/310/510,SQ510/810 SN210/310/510,SQ510/810 The highest temperature of 135deg.C Upwards opening lid SN210 SN310 SN510 Effective Capacity : 20LEffective Capacity : 32L Effective
Heating oven with mechanical control
ED series 53 Drying ovens / Heating ovens Heating oven with mechanical control The strength of the BINDER ED series heating oven: routine drying and sterilization applications up to 300 C (572 F). Thanks
Thermo Scientific VARIOKLAV Modular Laboratory Autoclaves Versatile, space-saving performance for steam sterilization applications
Thermo Scientific VARIOKLAV Modular Laboratory Autoclaves Versatile, space-saving performance for steam sterilization applications Part of Thermo Fisher Scientific Thermo Scientific Varioklav Laboratory
Portable Compressors MOBILAIR M 270 With the world-renowned SIGMA PROFILE Free air delivery 20.0 to 26.9 m³/min. www.kaeser.com
Portable Compressors MOBILAIR M 270 With the world-renowned SIGMA PROFILE Free air delivery 20.0 to 26.9 m³/min www.kaeser.com Made in Germany KAESER s renowned MOBILAIR range of portable compressors is
Laserlyte-Flex Alignment System
Laserlyte-Flex Alignment System LaserLyte-Flex The LaserLyte-Flex Alignment System is a unique, interchangeable, low cost plug and play laser system. Designed specifically for aligning and positioning
FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES
BQ FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES Versatility, power, compactness and low running costs are the main characteristics of B&C vane pumps. All the components subject to wear are contained
Vacuum drying oven for non-flammable solvents
VD series 53 Vacuum drying ovens Vacuum drying oven for non-flammable solvents A BINDER vacuum drying oven of the VD series is impressive while gently drying with its homogeneous temperature distribution.
Infection Control in the Dental Practice through Proper Sterilization
Midmark Corporation 60 Vista Drive P.O. Box 286 Versailles, Ohio 45380-0286 937-526-3662 midmark.com Infection Control in the Dental Practice through Proper Sterilization In today's world, the need for
CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE. General purpose single phase thyristors and solid state relays Product data.
425 CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE General purpose single phase thyristors and solid state relays Product data abc 425 EUROCUBE A complete range of low cost solid state relays and
Infrarot-Bewegungsmelder IP44
Infrarot-Bewegungsmelder IP44 infrared motion sensors IP44 ODA (weiß) slim ODA (schwarz) slim 95174 96000 ODA (weiß) ODA (schwarz) 95175 96001 Betriebsanleitung User s Manual User s Manual infrared motion
Fredriksons conveyor systems handle goods with a width from 20 mm up to 600 mm.
Conveyor Solutions Whatever your logistic needs, we can offer a conveyor solution. Our flexible systems primary and secondary packaging for single and multi packages, can transport your goods from one
Featuring fast rotor exchanges with AUTO-LOCK
Thermo Scientific Sorvall T1 Centrifuge Series Versatility, convenience and value for routine applications Featuring fast rotor exchanges with AUTO-LOCK Versatility, convenience and value for routine applications
Installation, operation and maintenance manual TX 35A
Installation, operation and maintenance manual TX 35A Rev.10 may 2012 Page 1 of 18 1.0.0 Table of contents INSTALLATION, OPERATION AND MAINTENANCE MANUAL...1 1.0.0 TABLE OF CONTENTS...2 2.0.0 ILLUSTRATIONS...2
MAP COFFEE MIA CAPSULE COFFEE MACHINE INSTRUCTION MANUAL MODEL: CM4725. Read this manual thoroughly before using and save it for future reference
MAP COFFEE MIA CAPSULE COFFEE MACHINE INSTRUCTION MANUAL MODEL: CM4725 Read this manual thoroughly before using and save it for future reference Purchase MAP capsules at Harvey Norman stores nationwide
KNX L. Brightness Sensor. Technical specifications and installation instructions Item number 70119
EN KNX L Brightness Sensor Technical specifications and installation instructions Item number 70119 Elsner Elektronik GmbH Control and Automation Engineering Herdweg 7 D 75391 Gechingen Phone +49 (0) 70
FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES
BQ FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES Versatility, power, compactness and low running costs are the main characteristics of B&C vane pumps. All the components subject to wear are contained
FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES
BQ FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES Versatility, power, compactness and low running costs are the main characteristics of B&C vane pumps. All the components subject to wear are contained
Design ideas for dental practices. With Sirona.
CAD/CAM SYSTEMS INSTRUMENTS HYGIENE SYSTEMS TREATMENT CENTERS IMAGING SYSTEMS FORM AND FUNCTION Design ideas for dental practices. With Sirona. T h e D e n t a l C o m p a n y Make your dental practice
6390830.book Seite 1 Freitag, 22. Juni 2012 12:43 12. qn=ifkb=l=qo=ifkb. Operating Instructions. båöäáëü. lééê~íáåö=áåëíêìåíáçåë
6390830.book Seite 1 Freitag, 22. Juni 2012 12:43 12 qn=ifkb=l=qo=ifkb Operating Instructions båöäáëü lééê~íáåö=áåëíêìåíáçåë 6390830.book Seite 2 Freitag, 22. Juni 2012 12:43 12 Table of contents 1 Before
FilterFlow Automatic Water Boilers. Pure Quality
FilterFlow Automatic Water Boilers Pure Quality Filtered hot water on tap Around the world we drink countless millions of cups of tea and coffee each and every day. The consumer s seemingly insatiable
Description of functions
Description of functions Laddomat 21 is designed to......allow the boiler to reach a high working temperature soon after firing....to preheat the cold tank water in the bottom of the boiler so that the
804 Ti Stand. Manual 8.804.8001EN
804 Ti Stand Manual 8.804.8001EN Metrohm AG CH-9101 Herisau Switzerland Phone +41 71 353 85 85 Fax +41 71 353 89 01 [email protected] www.metrohm.com 804 Ti Stand Manual 8.804.8001EN 06.2010 ek Teachware
Desiccant Air Dryers Heatless, Heated and Heated Blower
Desiccant Air Dryers Heatless, Heated and Heated Blower Desiccant Dryers... Desiccant Our reliable high strength, non-acidic desiccant provides maximum performance and is easily stored and handled. Environmentally
qn=ifkb=l=qo=ifkb=l=qp=ifkb
6390830.book Seite 1 Dienstag, 7. August 2012 3:39 15 qn=ifkb=l=qo=ifkb=l=qp=ifkb Operating Instructions båöäáëü lééê~íáåö=áåëíêìåíáçåë 6390830.book Seite 2 Dienstag, 7. August 2012 3:39 15 6390830.book
Digital panoramic X-ray for practical diagnostics
ORTHOPHOS XG 3 instruments treatment centers Imaging systems cad/cam systems ORTHOPHOS XG 3 Digital panoramic X-ray for practical diagnostics System concept Standard panoramic X-ray with proven technology.
TUTTNAUER OLD AUTOCLAVE OPERATING PROCEDURE
1 of 6 TUTTNAUER OLD AUTOCLAVE OPERATING PROCEDURE Aim The aim of this operating procedure is to equip the user with the knowledge to safely and successfully operate the old pressure chamber. This autoclave
CAR SEAT/ STROLLER INSTRUCTION MANUAL
CAR SEAT/ STROLLER INSTRUCTION MANUAL English PM-0624AB 3/98 Do not use this 4-in-1 System until you read and understand these instructions! IMPORTANT INFORMATION Thank you for selecting this 4-in-1 System
EXPRESS STILL WARNING It is legal in New Zealand to own and operate a still for the purpose of producing alcohol for your own consumption.
THE EXPRESS STILL This still represents the next generation in home distillation equipment. It eliminates the problem of having to spend all day processing a 25 litre wash. Taking 1 hour to heat up, then
18 LITER VOLUME STERILISATION MATERIALS TESTING MEDIA PREPARATION
18 LITER VOLUME STERILISATION MATERIALS TESTING MEDIA PREPARATION Applications THE WIDE RANGE OF USING CERTOCLAV AUTOCLAVES MICROBIOLOGY / BIO-CHEMISTRY Autoclave culture mediums Refuse sterilisation Efficiently
Vacuum Hair Clipper. 10,000 prize draw. Register online for HC6550. EXTRA year guarantee FREE rewards gallery
Vacuum Hair Clipper HC6550 Register online for 10,000 prize draw EXTRA year guarantee FREE rewards gallery Visit www.remington.co.uk/productregister You must register within 28 days of purchase. Thank
Assembly Instructions
city versa Assembly Instructions Read these instructions carefully before use and keep them for future reference. Your child s safety may be affected if you do not follow these instructions. This product
Installation Instructions 4662.003
Installation Instructions.00 SINGLE CONTROL KITCHEN FAUCET Thank you for selecting American-Standard...the benchmark of fine quality for over 00 years. To ensure that your installation proceeds smoothly--please
Incubator with mechanical convection
BF series 400 Incubators and cooling incubators Incubator with mechanical convection The BINDER incubator of the BF series with mechanical convection is suitable for all gentle incubation applications,
Select Radiators Installation Guide
Select Radiators Installation Guide Table of Contents Informational Symbols...3 Before You Begin...4 Select Rough-In... 5 Connection Installation...6 Optional Piping Arrangements...7 Conventional Wall
Automatic Back-Flushing Filter AutoFilt RF9.
Automatic Back-Flushing Filter AutoFilt RF9. AutoFilt RF9 Clearing the Way. The Challenge: In response to the Tier III standard which will come into effect in 2016, the International Maritime Organization
Manual for GlobePharma Mini-Press II Rotary Tablet Press
1 of 13 Preparing the Rotary Press 1. Make sure the rotary press is unplugged. 2. Open the bottom cabinet of the rotary press and take out the grey tool kit, and the beige box of punches and dies. 3. Take
The power of innovation. For better media preparation. Media preparators Systec MediaPrep.
The power of innovation. For better media preparation. Media preparators Systec MediaPrep. t h e a u t o c l a v e c o m p a n y Prepare and sterilize microbiological media. Fast, accurate and easy to
Please read and keep these instructions. Run water through your machine before first use
47070 Rev 1 24/3/05 2:23 PM Page 1 12 cup filter coffee maker Please read and keep these instructions getting the best from your new coffee maker Safety first Caution must be used when handling hot water,
Instructions Manual AmazonBasics 12-Sheet Cross-Cut Paper / CD / Credit Card Shredder with Basket ASIN# B005QAQFFS. Customer Service 1-866-216-1072
Instructions Manual AmazonBasics 12-Sheet Cross-Cut Paper / CD / Credit Card Shredder with Basket ASIN# B005QAQFFS Customer Service 1-866-216-1072 Paper Shredder Instructions Manual Sheet Capacity 12 Sheets
Handpieces. Ready for takeoff! The high-speed handpiece family T1, T2, T3
Handpieces Ready for takeoff! The high-speed handpiece family T1, T2, T3 > SIRONA offers outstanding performance in the economy class. That means top quality even for dentists with limited budgets. < Brenda
Wireless 7 Day Programmable Room Thermostat
Wireless 7 Day Programmable Room Thermostat Cat. No. TRT037 Transmitter Receiver Operating & Installation Instructions What is a programmable room thermostat? an explanation for householders A programmable
MH 3M & 4M. High pressure washers with hot benefits
MH 3M & 4M High pressure washers with hot benefits The EcoPower boiler provides high efficiency and lowest equivalent fuel consumption as certified by EUnited. All key functions placed for optimal ease-of-use.
UNITOR VACUUM cleaners
UNITOR VACUUM cleaners Unitor VCD15 a compact, heavy-duty dry vacuum cleaner for accommodation areas The smallest unit in the Unitor range, the VCD15 is purpose-made for use on cruise and passenger vessels.
STATFlow. Direct-to-Drain System. For use with STATIM 2000 and STATIM 5000 Autoclaves. Installation Guide and Operator s Manual
STATFlow Direct-to-Drain System For use with STATIM 2000 and STATIM 5000 Autoclaves Installation Guide and Operator s Manual STATFlow Installation Guide and Operator s Manual 95-113193 Rev 2.0. Copyright
ABLOY DOOR AUTOMATICS Easy access for all types of swing doors
ABLOY DOOR AUTOMATICS Easy access for all types of swing doors Automatic door operators bring additional convenience in situations where the doors opening manually would be inconvenient or laborious. Recommended
ACCESSORIES OXYGEN-THERAPY
OXYGEN-THERAPY English version 11/ 2010 HUMIDIFIERS The humidifier is used to humidify the oxygen or the medical air delivered to the patient through the respiratory tract. Screwed to the outlet of a flowmeter
INSTALLATION INSTRUCTIONS
Installation Instructions Ford Twin Disc Kits Serial #: Thank you for purchasing this quality ACT product. ACT has a long racing heritage supporting countless racers and series champions in many forms
Seeing CAD/CAM in a new light.
CAD/ CAM SYSTEMS INSTRUMENTS HYGIENE SYSTEMS TREATMENT CENTERS IMAGING SYSTEMS CEREC NEW PRODUCTS 2009 Seeing CAD/CAM in a new light. T h e D e n t a l C o m p a n y Precision and simplicity redefined.
GETINGE CLEAN MANAGEMENT SYSTEM
GETINGE CLEAN MANAGEMENT SYSTEM 2 Getinge Clean Management System GETINGE CLEAN MANAGEMENT SYSTEM (CMS) AN IMPROVED PROCESS, A UNIQUE SOLUTION Getinge can help you manage your detergents and reduce costs.
AUTOCLAVES. Table Top. STE-TEN, 1 Liter Autoclave
Table Top STE-TEN, 1 Liter utoclave STE-TEN It adopts B-wclass (pred-13060), with 3-times pre-vacuum preceding vacuum drying. Residual humidity is 0.2, vacuum measurement reaches -0.7bar. It sterilizes
TRIMMING TECH 150. IVD In vitro diagnostic-medical device. General information. Technical datasheet Trimmingtech150
IVD In vitro diagnostic-medical device CND code: W0202059016 - CIVAB code: TRIMMING TECH 150 General information Type of instrument: Aspirated hood for histology. Model: Trimming Tech 150. Code: Description:
Laddomat 21-60 Charging unit
Laddomat 21-60 Charging unit User and installation instructions NOTE! Diagrams in this brochure only describe connection principles. Each installation must be measured and carried out according to the
Instruction manual for Firstline FCS12000CH
Instruction manual for Firstline FCS12000CH Contents Introduction... 2 Safety Awareness... 3 Safety Awareness... 4 Name of Parts... 5 Name of Parts... 6 Remote Controller Preparation... 7 Operation of
HEAVY DUTY SEVERING AND BEVELLING MACHINE TNO FAB-SERIES
HEAVY DUTY SEVERING AND BEVELLING MACHINE TNO FAB-SERIES PROTEM USA LLC 29340 Industrial Way, # 402 Evergreen, CO 80439 USA Phone: +1 303 955 4862 Fax: +1 303 955 5904 [email protected] www.protemusa.com
Installation Guide 2010 BMW S1000RR Full Exhaust System
Installation Guide 2010 BMW S1000RR Full Exhaust System!! THIS PRODUCT IS DESIGNED FOR USE IN CLOSED COURSE RACING AND IS NOT INTENDED FOR HIGHWAY USE!! Congratulations on the purchase of your new TaylorMade
