DIGITAL SWITCHBOARD METERS

Size: px
Start display at page:

Download "DIGITAL SWITCHBOARD METERS"

Transcription

1 DIITAL SWITCHBOARD METER MODELS 2491, 2492, FEATURES The Model 2491 (Single function), Model 2492 (Dual function), and Model (Triple Function) Digital Switchboard Meters were developed to provide customers with a versatile AC digital power meter. Some of the unique features are: End user programmable for CT ratios and PT ratios End user selectable legends Watts, kwatts and mwatts, etc. Non-volatile memory. If loss of power occurs, all settings will remain the same. Accuracy of + 0.2% of reading, + 0.1% Full Scale. True RMS current and voltage measuring. Most desirable if distorted sine wave is present. Security of settings... Complete removal of cover is required to access selectable or programmable variables. Four push buttons are used for quick setup, except with front panel configuration. Display averaging... Programmable from 1 to 25 samples to eliminate annoying digit bounce. RS485 communication option allows up to 32 units to be networked together for remote reading. Analog output option allows ability to connect to data acquisition systems. Complete operating instruction manual included with each meter. NIST Calibrated Certificate/Test data available as an option. Modbus communication option allows connection to existing control systems (Single Function) 2492 (Dual Function) (Triple Function) AMPS/AC VOLTS/AC AMPS/AC VOLTS/AC AMPS/AC AMPS/AC AMPS/AC VOLTS/DC POWER VOLTS/AC VOLTS/AC \ FACTOR/ VOLTS/AC PHASE VOLTS/AC ANLE WATTS WATTS/ WATTS/ VARS VARS/ POWER FACTOR VARS WATTS/ VOLTS/AC POWER AMPS/AC FACTOR 171

2 ENERAL SPECIFICATIONS MODELS 2491, 2492, Display Auxiliary Power Input Rating Input Range Sustained Input Burden Accuracy Analog Output and Response Time Output Ripple Type Digit Height Response Time Current Voltage dc Voltage Frequency Rated Current Rated Voltage Rated Current Rated Voltage Rated Voltage () Current Voltage Reference Condition 25 C, 45-74% RH, at rated input 60Hz sine wave, 30 min. warmup 2491, to 1mA 4 to 20mA 12+8mA 4 digit Red LED for (3 displays) 4 1/2 digit Red LED for 2491, inch or 14mm 250millisecond minimum update time for V/V/V, A/A/A, 2491 and 2492 Less than 500ms min. update time for V/A/Hz, Watt/Var/PF 120V or 240Vac (+15%) 45-65Hz, 4.5VA max. Optional 24, 48, 125Vdc power supply 0 to 1 Aac; 0 to 5Aac 0-120Vac, 0-240Vac, 480Vac, (W/Var/PF/PA); 0-150Vac, 0-300Vac, 600Vac (Volt/Freq.) 0-150Vdc, 0-300Vdc,0-600Vdc 50/60Hz and 400Hz A/W/Var: 0-200%; PF/PA: % V/W/Var: 0-120%; PF/PA: %; Frequency: % A/W/Var/PF/PA: 200% continuous, 10x rating for 5 seconds V/W/Var/Freq.: 120% continuous; PF/PA: 150% continuous V/V/V: 120% continuous; W/Var/PF: 150% continuous <0.2Va per element 120V:<0.2Va per element; 240V:<0.4Va per element Voltage Current Watt/Var Power Factor Phase Angle Frequency +0.2% of reading + 0.1% of full scale Power Factor +0.5 Phase Angle 40-70Hz, Hz 10Vdc compliance into 10K Ω load maximum 15Vdc compliance into 750 Ω maximum 1 second maximum response time within +1% of final value 0.5% peak-to-peak maximum of output scan Communications Optional RS-485 half duplex interface with networking up to 32 units and Modbus Isolation Voltage/ Insulation Resistance Temperature Range Temperature Coefficient Input Frequency Range Influence of Surge Withstand Voltage Input to Output/case Aux. power to case Aux. power to output Output to case 2491 dc Operating Storing Display & Comm. Analog Output Volt, Amp, Hertz Magnetic field Shock/vibration Input voltage Current Unbalanced current Input frequency Load resistance Analog output SWC tests 2500Vac for 1 minute/more than Vdc 2000Vac for 1 minute/more than Vdc dc auxilliary power: 500Vdc minimum/10 Megohm 2000Vac for 1 minute/more than Vdc dc auxilliary power: 500Vdc 100Vdc 1000Vac for 1 minute/more than Vdc -20 C to +60 C at 90% RH maximum (non-condensing) -40 C to +85 C +150PPM/ C maximum of full scale +250PPM/ C maximum of full scale 45-65Hz fundamental through the 9th harmonic within +2.0% of specified accuracy 0.5% maximum at 400 ampere turns/meter <0.2% after: 50 x 3 axis x 6 repetitions/16.7hz, 4mm p-p for one hour (Per Ansi C39.1) <0.05 Power Factor (10 to 120% of rated voltage) 5-200% of rated current <0.2% of full scale <0.05 (45-65Hz) Power Factor 0 to 1mA, 0-10 kilo ohm within +0.05% of full scale 4 to 20mA, 12+8mA: ohm within +0.05% of full scale Meets IEEE 472/ANSI C37.90a Meets JIS C1111 (5kV 1.2 x 50 microseconds) Dimensions W x D x H = 4.33" x 6.54" x 4.33" Weight Meter with hardware 1000gm. (2.2 lbs.) or less Design Std. ANSI C39.1 (American National Standards Institute) 172

3 AMPS - VOLTS - (SINLE FUNCTION) MODEL 2491 FUNCTION Amps AC Volts AC Volts DC Frequency INPUT RATIN A 0... None AAA... No Output 1... RS A /60Hz AFA mA 2... MODBUS V Hz AHD mA V V Vdc Vdc Vdc 1. Maximum scaling ratio for Amps is 9999:1 2. Maximum scaling ratio for Volts is 9999:1 3. AHD suffix not available with frequency meter /240Vac Vdc Vdc Vdc Ordering Example: AHD-1-1 is an AC Voltmeter, 150Vac, 50/60Hz with a 4-20mA output and 120/240Vac Auxiliary Power AC WATTS - AC VARS (SINLE FUNCTION) MODEL 2491 FUNCTION/CONNECTIONS Watt...1W (1 Element) Watt...1P3W (2 Element) Watt...3P3W (2 Element) Watt...3P4W (2 1/2 Element) Watt...3P4W (3 Element) Vars...1W (1 Element) Vars...1P3W (2 Element) Vars...3P3W (2 Element) Vars...3P4W (2 1/2 Element) Vars...3P4W (3 Element) AC INPUT RATIN Volt/1Amp Volt/5Amp Volt/1Amp Volt/5Amp Volt/1Amp Volt/5Amp /60Hz AAA... No Output AFA mA AHD mA AHF mA ( ) 1... RS MODBUS /240Vac Vdc Vdc Vdc Watts/Kilowatts/Megawatts/ and Vars/Kilovars/Megavars legends are user selectable. Ordering Example: AFA-1-1 is a 3P3W Wattmeter; 120V/5Amp, 50/60Hz, 0-1mA output, and 120/240Vac Auxiliary Power POWER FACTOR/PHASE ANLE (SINLE FUNCTION) FUNCTION/CONNECTIONS PF...1W (1 Element) PF...1P3W (2 Element) PF...3P3W (2 Element) PF...3P4W (2 1/2 Element) PF...3P4W (3 Element) PA...1W (1 Element) PA...1P3W (2 Element) PA...3P3W (2 Element) PA...3P4W (2 1/2 Element) PA...3P4W (3 Element) AC INPUT RATIN Volt/1Amp Volt/5Amp Volt/1Amp Volt/5Amp Volt/1Amp Volt/5Amp /60Hz AAA... No Output AFA mA AHD mA AHF mA ( ) MODEL RS MODBUS /240Vac Vdc Vdc Vdc 1. These models have a 3 1/2 digit display 2491 Ordering Example: AFA-1-1 is a 3P3W Power Factor Meter; 120V/5Amp, 50/60Hz, 0-1mA output, and 120/240Vac Auxiliary Power 173

4 AC VOLT / AMP (DUAL FUNCTION) MODEL 2492 FUNCTION 12...Volt/Amp INPUT RATIN Volt/1Aac Volt/1Aac Volt/1Aac Volt/5Aac Volt/5Aac Volt/5Aac Hz 1. Maximum scaling ratio for Volts is 9999:1; For Amps it is 9999: Ordering Example: AHD-1-1 is a 150V/5Aac, 50/60Hz Dual Meter with 4-20mA output and 120/240Vac Auxiliary Power AC VOLT / (DUAL FUNCTION) MODEL 2492 FUNCTION 22...Volt/Frequency INPUT RATIN Volt Volt Volt Hz 1. Maximum scaling ratio for Volts is 9999: Ordering Example: AFA-1-1 is a Volt/Frequency Meter; 150V, 50/60Hz, 0-1mA outputs and 120/240Vac Auxiliary Power AC WATT / VAR (DUAL FUNCTION) FUNCTION/ AC INPUT RATIN CONNECTIONS Volt/1Amp 40...Watt/Var... 1W Volt/5Amp 41...Watt/Var... 1P3W Volt/1Amp 42...Watt/Var... 3P3W Volt/5Amp 43...Watt/Var... 3P4W Volt/1Amp (2 1/2 Element) Volt/5Amp 44...Watt/Var... 3P4W (3 Element) AC WATT / POWER FACTOR (DUAL FUNCTION) FUNCTION/ AC INPUT RATIN CONNECTIONS Volt/1Amp 45...Watt/PF... 1W Volt/5Amp 46...Watt/PF... 1P3W Volt/1Amp 47...Watt/PF... 3P3W Volt/5Amp 48...Watt/PF... 3P4W Volt/1Amp (2 1/2 Element) Volt/5Amp 49...Watt/PF... 3P4W (3 Element) AHF mA ( ) 1. Maximum scaling ratio for Voltage is 9999:1; For Amps it is 9999:1 2. Watts/Kilowatts/Megawatts and Vars Kilovars/Megavars legends are user selectable MODEL 2492 Ordering Example: AFA-1-1 is a 3P3W Watt/Var Meter; 120V/5A, 50/60Hz, 0-1mA outputs and 120/240Vac Auxiliary Power MODEL 2492 AHF mA ( ) 1. Maximum scaling ratio for Voltage is 9999:1; For Amps it is 9999:1 2. Watts/Kilowatts/Megawatts legends are user selectable Ordering Example: AFA-1-1 is a 3P3W Watt/PF Meter; 120V/5A, 50/60Hz with 0-1mA outputs and 120/240Vac Auxiliary Power 174

5 VOLT/VOLT/VOLT (TRIPLE FUNCTION) FUNCTION P3W P4W INPUT RATIN/ CONNECTIONS Vac Vac Vac Hz MODEL 1. Maximum scaling ratio for Volts is 9999:1 Ordering Example: AHD-1-1 is a 3P3W, 150V, 50/60Hz, Triple Meter with 4-20mA outputs and 120/240Vac Auxiliary Power AMP/AMP/AMP (TRIPLE FUNCTION) MODEL FUNCTION Phase Amps A, B, C INPUT RATIN 01..1Aac 05..5Aac Hz 1. Maximum scaling ratio is 9999:1 Ordering Example: AHD-1-1 is a 0-5A, 50/60Hz Triple Meter with 4-20mA outputs and 120/240Vac Auxiliary Power VOLT/AMP/ (TRIPLE FUNCTION) MODEL CONNECTIONS 07..1W 08..3P3W Delta 09..3P4W Wye 1. Maximum scaling ratio for Volts is 9999:1; for Amps it is 9999:1 WATT/VAR/PF (TRIPLE FUNCTION) CONNECTIONS W P3W P3W P4W (2.5 Element) P4W (3 Element) VOLT/AMP RATIN V/1Aac V/5Aac V/1Aac V/5Aac V/1Aac V/5Aac VOLT/AMP RATIN V/1Aac V/5Aac V/1Aac V/5Aac V/1Aac V/5Aac Hz 1. Maximum scaling ratio for Volts is 9999:1; for Amps it is 9999:1 Ordering Example: AHD-1-1 is a 3P4W, 150V/5A, 50/60Hz Triple Meter with 4-20mA outputs and 120/240Vac Auxiliary Power MODEL Ordering Example: AHD-1-1 is a 3P4W(3Ele), 120V/5A, 50/60Hz Triple Meter with 4-20mA outputs and 120/240Vac Auxiliary Power 175

6 TERMINAL CONNECTIONS MODEL L + - P1 COMM COMM + - PS- PS+ + - PS- PS AC Ammeter AC Voltmeter Frequency Meter DC SOURCE COMM L P1 + - COM+ COM- PS-PS DC Volt Meter / / / Watts / Vars / P.F. / Phase Angle (1W) 3S P L 3L P1 L3 3S L 3L P1 P3 L3 COM+ COM- PS-PS / / / Watts / Vars / P.F. / Phase Angle (1P3W) COM+ COM / / / Watts / Vars / P.F. / Phase Angle (3P3W) 176

7 TERMINAL CONNECTIONS MODELS 2491, 2492 L3 N 2S 3S P L 2L 3L P1 P3 2S 3S P L 2L 3L P1 P3 COM+COM- COM+COM / / / Watts / Vars / P.F. / Phase Angle (3P4W) (2½ Element) 01-Volts 02-Amps / / / Watts / Vars / P.F. / Phase Angle (3P4W) (3 Element) 01-Volts 02-Frequency L P COM+ COM- 01-Watts 02-Vars, P.F L P Dual Function Volts / Amps 01-Watts 02-Vars, P.F P COM+ COM- 3S P L 3L P1 P Dual Function Volts / Hertz N L COM+ COM COM+ COM- PS-PS / Dual Function Watts / Vars,Watts / P.F. (1W) / Dual Function Watts / Vars,Watts / P.F. (1P3W)

8 TERMINAL CONNECTIONS MODEL Watts 02-Vars, P.F. L3 01-Watts 02-Vars, P.F. 3S L 3L P1 2S 3S P L 2L 3L P1 P COM+ COM COM+ COM / Dual Function / Watts / Vars and Watts / P.F. (3P3W) / Dual Function / Watts / Vars and Watts / P.F. (3P4W 2 1/2 Element) 01-Watts 02-Vars, P.F. DIMENSIONS MODEL 2491 / 2492 / 2S 3S P L 2L 3L P1 P COM+ COM SQ /4-28 (4) 0.60 (4) 0.03 (4) DIA. #8 ROUND STUD DIA. (4) / Dual Function / Watts / Vars and Watts / P.F. (3P4W 3 Element) All Dimensions In Inches 178

9 TERMINAL CONNECTIONS MODEL 01-Ph. 1 Amps 02-Ph. 2 Amps 03-Ph. 3 Amps L3 01-Ph. 1 Volts (L-N) 02-Ph. 2 Volts (L-N) 03-Ph. 3 Volts (L-N) L S 3S 01-1L 2L 3L P1 P COM+ COM COM+ COM- 05 Amps / Amps / Amps 01 (3P3W) Volts/ Volts / Volts 01-Ph. 1 Volts 02-Ph. 2 Volts 03-Ph. 3 Volts 01-Ph. 1 Volts 02-Ph. 2 Amps 03-Ph. 3 Frequency P L P P Ph. 1 Volts 02-Ph. 2 Amps 03-Ph. 3 Frequency 2S 3S L 2L 3L P1 P3 02 (3P4W) Volts / Volts / Volts L Ph. 1 Volts 02-Ph. 2 Amps 03-Ph. 3 Frequency 07 (1W) Volts / Amps / Frequency 2S 3S P L 2L 3L P1 P COM+ COM- PS-PS+ 08 (3P3W) Volts / Amps / Frequency COM+ COM- 09 (3P4W) Volts / Amps / Frequency

10 TERMINAL CONNECTIONS MODEL 01-Watt 02-Var 03-P.F. 01-Watt 02-Var 03-P.F. N L L P1 3S P COM+ COM L 3L P1 P3 34 (1 Phase, 2 Wire) Watts / Vars / Power Factor Watt 02-Var 03-P.F. L3 35 (1 Phase, 3 Wire) Watts / Vars / Power Factor 01-Watt 02-Var 03-P.F. 3S L 3L P1 P3 2S 3S P L 2L 3L P1 P COM+ COM- 01-Watt 02-Var 03-P.F. 36 (3 Phase, 3 Wire) Watts / Vars / Power Factor COM+COM- 37 (3 Phase, 4 Wire, 2 1/2 Element) Watts / Vars / Power Factor 2S 3S P L 2L 3L P1 P3 38 (3 Phase, 4 Wire, 3 Element) Watts / Vars / Power Factor COM+ COM- 180

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features: Application : RISH Master 3490 DS measures important electrical parameters of Utility (in normal mode) & Generators (in Power back up) in three phase and single phase Network & replaces the multiple analog

More information

Panel Meters and Controllers Modular Panel Meter Type EDM 35

Panel Meters and Controllers Modular Panel Meter Type EDM 35 Panel Meters and Controllers Modular Panel Meter Type EDM 35 Modular digital panel meter, 3 1/2-digit Indicating or controlling current, voltage, resistance, temperature, tacho or frequency. Easy programming

More information

Multilin EPM 6000. GE Grid Solutions. High Accuracy Power & Energy Measurement. Monitoring & Metering. Advanced Communications.

Multilin EPM 6000. GE Grid Solutions. High Accuracy Power & Energy Measurement. Monitoring & Metering. Advanced Communications. GE Grid Solutions Multilin EPM 6000 High Accuracy Power & Energy Measurement The Multilin EPM 6000 is one of the industry s highest performance revenue grade panel meters with superior cost to performance

More information

Dielectric Withstand and Ground Bond Testers For Production Line Safety Agency Compliance Testing

Dielectric Withstand and Ground Bond Testers For Production Line Safety Agency Compliance Testing Dielectric Withstand and Ground Bond Testers For Production Line Safety Agency Compliance Testing U.S. patent#: 5,548,501, 6,054,865. Other patents pending. Safety agency listed. ENHANCED GRAPHIC LCD The

More information

Energy Management Power Analyzer Type WM14-96 Basic Version

Energy Management Power Analyzer Type WM14-96 Basic Version Energy Management Power Analyzer Type WM-96 Basic Version Optional dual pulse output Alarms (visual only) V, An Optional galvanically insulated measuring inputs Product Description 3-phase power analyzer

More information

Power-monitoring unit PowerLogic System. Technical data sheet. Power Meter Series 800

Power-monitoring unit PowerLogic System. Technical data sheet. Power Meter Series 800 Power-monitoring unit PowerLogic System Technical data sheet 2003 Power Meter Series 800 Function and characteristics PB100313 The PowerLogic Power Meter Series 800 offers all the high-performance measurement

More information

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410 The INTEG is an Ethernet I/O (digital, analog) device that monitors and controls a small set of process signals. functions as both basic I/O for integration with another application or system AND as a

More information

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER Application : The RISH CON - Hz transducer is used for frequency measurement. The output signal is proportional to measured frequency and is either load independent DC Current or load independent DC Voltage.

More information

Energy Management Energy Meter Type EM23 DIN

Energy Management Energy Meter Type EM23 DIN Energy Management Energy Meter Type EM23 DIN Class 1 (kwh) according to EN62053-21 Class B (kwh) according to EN50470-3 Class 2 (kvarh) according to EN62053-23 Accuracy ±0.5 RDG (current/voltage) Energy

More information

FREJA 300 Relay Testing System

FREJA 300 Relay Testing System Relay Testing System A Megger Group Company FREJA 300 Relay testing system The FREJA 300 relay testing system is a computer-aided relay testing and simulation system. The weight of FREJA 300 is only 15

More information

CONTENTS. PAGE Chapter 1 General Information 1. Chapter 2 Setup 4 DP450-VDC 7 DP450-VAC 7 DP450-DCC 7 DP450-F 8 DP450-HACC 9 DP450-HDCC 11 DP450-E 13

CONTENTS. PAGE Chapter 1 General Information 1. Chapter 2 Setup 4 DP450-VDC 7 DP450-VAC 7 DP450-DCC 7 DP450-F 8 DP450-HACC 9 DP450-HDCC 11 DP450-E 13 CONTENTS PAGE Chapter 1 General Information 1 Chapter 2 Setup 4 DP450-VDC 7 DP450-VAC 7 DP450-DCC 7 DP450-F 8 DP450-HACC 9 DP450-HDCC 11 DP450-E 13 Chapter 3 Alarm/Excitation Options 15 Wiring 17 Chapter

More information

AZ420 MINIATURE GENERAL PURPOSE RELAY

AZ420 MINIATURE GENERAL PURPOSE RELAY MINIATURE GENERAL PURPOSE RELAY FEATURES Rugged construction for high reliability Life expectancy greater than 0 million operations DC coils to 11 V Power consumption as low as 2 mw per pole available

More information

Features. Display. Measurements. Intelligent. Accuracy. Models. Installation DEIF A/S. Multi-instrument 4921210109D

Features. Display. Measurements. Intelligent. Accuracy. Models. Installation DEIF A/S. Multi-instrument 4921210109D 7000/7000C/7020 Multi-instrument 4921210109D Features Measurements All 3-phase AC measurements True RMS Replaces analogue meters Demand on each phase current Accuracy U, I and F class 0.5 Other values

More information

Metering Devices IQ Analyzer 6400/6600 Series

Metering Devices IQ Analyzer 6400/6600 Series Metering Devices IQ Analyzer 6400/6600 Series Technical Data Supersedes TD.17.02A.T.E pages 1-8 dated May 2000 Description Page General Description............................................. 2 Applications....................................................

More information

Analog signal converters CC-E I/I Current / current isolators

Analog signal converters CC-E I/I Current / current isolators ata sheet Analog signal converters CC-E I/I Current / current isolators The CC-E I/I is an isolator for the electrical isolation of current signals without auxiliary supply. It allows the isolation between

More information

SWITCH! DESCRIPTION. ENVIRONMENTAL SPECIFICATIONS Operating Temperature: 0 C to +40 C SPECIFICATION SHEET:

SWITCH! DESCRIPTION. ENVIRONMENTAL SPECIFICATIONS Operating Temperature: 0 C to +40 C SPECIFICATION SHEET: SWITCH The Budderfly lighting switch is a Decora style, plug-and-play replacement for your existing building switches. Installing a Budderfly adapter transforms your building s existing wiring into the

More information

Digital Energy ITI. Instrument Transformer Basic Technical Information and Application

Digital Energy ITI. Instrument Transformer Basic Technical Information and Application g Digital Energy ITI Instrument Transformer Basic Technical Information and Application Table of Contents DEFINITIONS AND FUNCTIONS CONSTRUCTION FEATURES MAGNETIC CIRCUITS RATING AND RATIO CURRENT TRANSFORMER

More information

Product Guide AC Voltage Control Devices. Guide Guide. Popular Variable Transformers and AC Power Supplies. www.stacoenergy.com

Product Guide AC Voltage Control Devices. Guide Guide. Popular Variable Transformers and AC Power Supplies. www.stacoenergy.com Popular Variable Transformers and AC Power Supplies Product Guide AC Voltage Control Devices Guide Guide Your Tailored Power Solutions Provider TM Staco Energy Products Co. has been a leading manufacturer

More information

DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters Testing all relay technologies: electromechanical, solid state, numerical and IEC61850 Manual

More information

Table of Contents. TransformerIQ FAQs 1

Table of Contents. TransformerIQ FAQs 1 [12/12] FAQs Table of Contents FAQ 1. What size transformer will TransformerIQ monitor?... 2 FAQ 2. Are there different TransformerIQ versions?... 2 FAQ 3. How are the units powered?... 2 FAQ 4. What is

More information

Applications. diris_826_a_1_gb_cat

Applications. diris_826_a_1_gb_cat Measurement units NEW diris_824_a_1_cat Energy monitoring and management of low voltage/ high voltage electrical installations Function are measurement units which can provide all the functions offered

More information

Crompton Instruments. ANSI Switchboard Meters

Crompton Instruments. ANSI Switchboard Meters Crompton Instruments ANSI Switchboard Meters www.crompton-instruments.com Crompton Instruments ANSI SWITCHBOARD METERS An extensive range of analog and digital/analog meters in the 4½" ANSI case style.

More information

CURRENT TRANSFORMER MODEL 546 UL1015 #16 AWG LEAD WIRE, STANDARD LENGTH IS 24" 1 X

CURRENT TRANSFORMER MODEL 546 UL1015 #16 AWG LEAD WIRE, STANDARD LENGTH IS 24 1 X CURRENT TRANSFORMER MODEL 546 1.10" I.D. PAGE No 1-38 REV 15DEC00 TERMINAL OPTION LEAD WIRE OPTION 1.10 0 1.20 2.55 3.00 3.47 0.18 x 0.31 SLOT ( 2 PLACES) 8-32 BRASS STUD (2 PLACES) UL1015 #16 AWG LEAD

More information

VOLTAGE REGULATOR AND PARALLEL OPERATION

VOLTAGE REGULATOR AND PARALLEL OPERATION VOLTAGE REGULATOR AND PARALLEL OPERATION Generator sets are operated in parallel to improve fuel economy and reliability of the power supply. Economy is improved with multiple paralleled generators by

More information

Power Meter Series 700

Power Meter Series 700 PowerLogic power-monitoring units Power Meter Series 700 Technical data sheet 2007 Functions and characteristics E90463 The PowerLogic Power Meter Series 700 offers all the measurement capabilities required

More information

Quick Connect. quick - simple - efficient. www.g-mw.de

Quick Connect. quick - simple - efficient. www.g-mw.de Quick Connect quick - simple - efficient www.g-mw.de Phone: +49 9103 7129-0 Fax: +49 9103 7129-207 Innovative connection technology to plug three single-phase current transformers to multifunctional power

More information

A project to optimise quality and energy efficiency must include metering

A project to optimise quality and energy efficiency must include metering EMDX 3 : Energy Metering A project to optimise quality and energy efficiency must include metering Metering upstream identifies the critical points and ensures optimum targeting of the actions to be taken,

More information

Meter Relays. 077 Series Analogue Meter Relays. Features. Applications

Meter Relays. 077 Series Analogue Meter Relays. Features. Applications 077 Series Analogue Features Monitors and controls any variable which can be converted to an A.C. or D.C. signal. Rugged, shock and vibration resistant design Indicator, relays and power unit in one housing

More information

Polyphase kwh Electricity Meter

Polyphase kwh Electricity Meter Polyphase kwh Electricity Meter Model Type: 5192B USER MANUAL Issue 1.0 E & O E AMPY Automation Ltd. July 2003 doc. ref. CSD 093 Contents 1 Introduction 2 1.1 Purpose 2 2 Definitions 2 2.1 References 2

More information

UNIVERSITY OF WASHINGTON Facilities Services Design Guide. Electrical. Metering and Monitoring. Basis of Design

UNIVERSITY OF WASHINGTON Facilities Services Design Guide. Electrical. Metering and Monitoring. Basis of Design Basis of Design This section applies to the design, installation and integration of metering and monitoring equipment, including: hardware installed in the electrical service and distribution equipment,

More information

How To Use A Cdm250 Digital Multimeter

How To Use A Cdm250 Digital Multimeter User Manual CDM250 Digital Multimeter 070-6736-03 Copyright Tektronix, Inc. 1987. All rights reserved. Tektronix products are covered by U.S. and foreign patents, issued and pending. Information in this

More information

1.44 kw Programmable DC Power Supplies XLN Series

1.44 kw Programmable DC Power Supplies XLN Series Data sheet 1.44 kw Programmable DC Power Supplies XLN Series New Family of High Density System Power Supplies The B&K Precision XLN series are compact, programmable, single-output DC power supplies, suitable

More information

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q605 0054 R0001

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q605 0054 R0001 Analogue Input, -fold, MDRC, GH Q605 005 R0001 The analogue input is a DIN rail mounted device for insertion in the distribution board. It is connected to the EIB via the bus connecting terminal supplied.

More information

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs E031026 000823 Process modules Digital input PMI for inputs for 120 V AC inputs PMI Input E4, E5, GND L- PMI 120 V AC Input E4, E5, Common C E6, E7, GND L- E6, E7, Common C LEDs for the inputs operation

More information

MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter

MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter Thermal Mass meter and Temperature Transmitter Description The MTI10 insertion thermal mass flowmeter and the MTL10 in-line thermal mass flowmeter provide accurate mass flow measurement of clean, dry gases

More information

AC Generators. Basic Generator

AC Generators. Basic Generator AC Generators Basic Generator A basic generator consists of a magnetic field, an armature, slip rings, brushes and a resistive load. The magnetic field is usually an electromagnet. An armature is any number

More information

650W Single Output Power Supply 15V 24V. 27V 48V Rated Current. 0 ~ 100A 0 ~ 50A 0 ~ 40A 0 ~ 27A 0 ~ 24A 0 ~ 13.6A Rated Power

650W Single Output Power Supply 15V 24V. 27V 48V Rated Current. 0 ~ 100A 0 ~ 50A 0 ~ 40A 0 ~ 27A 0 ~ 24A 0 ~ 13.6A Rated Power Features: Universal AC input / Full range Programmable output Voltage (0% ~ 05%) Programmable output Current (% ~ 05%) + / 0.5A auxiliary output Forced current sharing at parallel operation Power OK signal

More information

LTR Series Uninterruptible Power Systems 700 VA - 2.1 KVA. General Specification

LTR Series Uninterruptible Power Systems 700 VA - 2.1 KVA. General Specification 08/17/12 Rev2 LTR Series General Specification 700 VA to 2.1 KVA 1.0 General LTR Series Uninterruptible Power Systems 700 VA - 2.1 KVA General Specification This specification describes the features and

More information

1000W Single Output Power Supply 15V 24V. Protection type: Total Power limit, Latch-style (Recovery after reset AC power ON or inhibit)

1000W Single Output Power Supply 15V 24V. Protection type: Total Power limit, Latch-style (Recovery after reset AC power ON or inhibit) 000W Single Output Power Supply AK-000 series Features: Universal AC input / Full range Programmable output Voltage (0% ~ 05%) Programmable output Current (% ~ 05%) + / 0.5A auxiliary output U profile,

More information

CruzPro VAF110. AC Volts, Amps, Frequency, kw Monitor

CruzPro VAF110. AC Volts, Amps, Frequency, kw Monitor CruzPro VAF110 AC Volts, Amps, Frequency, kw Monitor Table of Contents Introduction............................ 3 Specifications........................... 4 Installation..............................5

More information

PRODUCT GUIDE. SL Medium Voltage IEC Vacuum Contactors

PRODUCT GUIDE. SL Medium Voltage IEC Vacuum Contactors PRODUCT GUIDE SL Medium Voltage IEC Vacuum Contactors Table of Contents 1 Overview Introduction....................................................2 Features........................................................2

More information

O WA-120U series IP67. 120W Single Output Switching Power Supply. Features. Aplications

O WA-120U series IP67. 120W Single Output Switching Power Supply. Features. Aplications Features UniversalACinput/Fulrange Built-inactivePFCfunction Higheficiencyupto91% Protections:Shortcircuit/Overcurent/ Overvoltage/Overtemperature Fanlesdesign,colingbyfreairconvection Colingbyfreairconvection

More information

T 3000. Substation Maintenance and Commissioning Test Equipment

T 3000. Substation Maintenance and Commissioning Test Equipment T 3000 Substation Maintenance and Commissioning Test Equipment Multi function system for testing substation equipment such as: current, voltage and power transformers, all type of protection relays, energy

More information

NC-12 Modbus Application

NC-12 Modbus Application NC-12 Modbus Application NC-12 1 Table of Contents 1 Table of Contents... 2 2 Glossary... 3 SCADA...3 3 NC-12 Modbus in general... 3 4 Entire system... 4 4.1 PFC to PC connection alternatives...4 4.1.1

More information

H/L = Power supply. FN = Nominal Frequency. RN = Rated value of output burden. UN = Nominal input voltage. IN = Nominal input current.

H/L = Power supply. FN = Nominal Frequency. RN = Rated value of output burden. UN = Nominal input voltage. IN = Nominal input current. Application : The transducer RISH CON - CA/CV (Fig.1) converts a sinusoidal AC Current or AC Voltage into a load independent DC Current or a load independent DC Voltage proportional to the measured value.

More information

Thyristor-controlled power supplies and battery chargers

Thyristor-controlled power supplies and battery chargers Thyristor-controlled power supplies and battery chargers Input voltage: 115 / 230 VAC, single phase, 50 / 60 Hz or 208 / 400 / 480 VAC, three phases, 50 / 60 Hz Output voltage: 12 / 24 / 48 / 60 / 72 /

More information

Centro-Matic Automatic Lubrication Systems System Controls

Centro-Matic Automatic Lubrication Systems System Controls Selecting the right controls for your automated lubrication system is one of the last steps in the design process. Several different models may be chosen to control power-operated pumps, depending on the

More information

DS 600. A contact free flux gate based current measurement sensor 600A rms

DS 600. A contact free flux gate based current measurement sensor 600A rms DS 600 A contact free flux gate based current measurement sensor 600A rms DS 600 is member of the small housing sensor family. The family includes a 200A and a 600A version. 600A rms - 900A peak Maximum

More information

Section D..General Auto Electrical Corporation

Section D..General Auto Electrical Corporation 43 Section D..General Auto Electrical Corporation 1. LED Based Signal unit GAEC manufacture LED based signaling system for use in electrified and non electrified sections of Indian railways. The exceptional

More information

THERMAL ANEMOMETRY ELECTRONICS, SOFTWARE AND ACCESSORIES

THERMAL ANEMOMETRY ELECTRONICS, SOFTWARE AND ACCESSORIES TSI and TSI logo are registered trademarks of TSI Incorporated. SmartTune is a trademark of TSI Incorporated. THERMAL ANEMOMETRY ELECTRONICS, SOFTWARE AND ACCESSORIES IFA 300 Constant Temperature Anemometry

More information

DCS Series 1 kw, 1.2 kw, & 3 kw

DCS Series 1 kw, 1.2 kw, & 3 kw DCS Series 1 kw, 1.2 kw, & 3 kw AVAILABLE WITH LXI STANDARD COMPLIANT ETHERNET Applications Automotive Electronics Rackmount ATE System Battery Charging DCS Series DCS Series: 1 kw, 1.2 kw, & 3 kw DCS

More information

Galleon 6-10K Online UPS. Voltronic Power Technology Corporation

Galleon 6-10K Online UPS. Voltronic Power Technology Corporation Galleon 6-10K Online UPS Voltronic Power Technology Corporation Features Galleon online UPS series delivers optimal power quality, provides superior power management, resolves utility power protection

More information

Series 427. 1/16 DIN Multi-Mode Bar Graph Display Timer TIMERS PRODUCT HIGHLIGHTS

Series 427. 1/16 DIN Multi-Mode Bar Graph Display Timer TIMERS PRODUCT HIGHLIGHTS Series 427 1/16 DIN Multi-Mode Bar Graph Display Timer PRODUCT HIGHLIGHTS Digital Setting with 0.1% Accuracy Unique LED Bargraph Indicates Time Cycle in 20% Increments 8 Field Selectable Modes of Operation

More information

Agilent E3633A and E3634A DC Power Supplies

Agilent E3633A and E3634A DC Power Supplies Service Guide Part Number: E3634-90010 Seventh Edition, April 21, 2014 Copyright Agilent Technologies, Inc. 1998 2014 All Rights Reserved. Agilent E3633A and E3634A DC Power Supplies Agilent Technologies

More information

POWERLOGIC Circuit Monitor Series 2000

POWERLOGIC Circuit Monitor Series 2000 Class POWERLOGIC Circuit Monitor Series 2000 Features True rms metering Certified ANSI C2.6 revenue accuracy High accuracy 0.2% current and voltage Power quality readings THD, k-factor, crest factor Over

More information

Agilent E363xA Series Programmable DC Power Supplies. Data Sheet

Agilent E363xA Series Programmable DC Power Supplies. Data Sheet Agilent E363xA Series Programmable DC Power Supplies Data Sheet Reliable Power, Repeatable Results Single and triple output 80 W to 200 W output power Dual range output Low noise and excellent regulation

More information

Pow-R-Con Multi Function Control

Pow-R-Con Multi Function Control 37264 Pow-R-Con Multi Function Control Product Specification Product Specification 37264 Product Information DYNA Power Controls Pow-R-Con TM GENERAL The Barber-Colman Pow-R-Con TM represents an integrated

More information

SX460. Generator Automatic Voltage Regulator Operation Manual

SX460. Generator Automatic Voltage Regulator Operation Manual SX460 Generator Automatic Voltage Regulator Operation Manual Self Excited Automatic Voltage Regulator Compatible with Newage SX460* * Use for reference purpose only and not a genuine Newage product. 1.

More information

VOLTAGE/CURRENT CALIBRATOR ISO-TECH ILC-421

VOLTAGE/CURRENT CALIBRATOR ISO-TECH ILC-421 VOLTAGE/CURRENT CALIBRATOR ISO-TECH ILC-421 TABLE OF CONTENTS 1. FEATURES... 1 2. SPECIFICATIONS... 1 2-1 General Specifications...1 2-2 Electrical Specifications... 2 3. FRONT PANEL DESCRIPTION... 4 3-1

More information

7-41 POWER FACTOR CORRECTION

7-41 POWER FACTOR CORRECTION POWER FTOR CORRECTION INTRODUCTION Modern electronic equipment can create noise that will cause problems with other equipment on the same supply system. To reduce system disturbances it is therefore essential

More information

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODELS: 61-763 61-765

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODELS: 61-763 61-765 IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODELS: 61-763 61-765 The Service Information provides the following information: Precautions and safety information Specifications Performance test procedure Calibration

More information

Voltage Regulator SPAU 341 C. Product Guide

Voltage Regulator SPAU 341 C. Product Guide Issued: July 1998 Status: Updated Version: D/25.04.2006 Data subject to change without notice Features Comprehensive voltage regulation for power transformers with on-load tapchangers in distribution substations

More information

Application/Connection Examples

Application/Connection Examples This Quick Start Guide is designed to familiarize the user with the connection and configuration of the DTS-305 DIN rail mounted single / 3 phase power & energy meter with RS-485 or TCP communications.

More information

AUTOMATIC TRANSFER SWITCH. Changeover Type from 250A to 2500A

AUTOMATIC TRANSFER SWITCH. Changeover Type from 250A to 2500A AUTOMATIC TRANSFER SWITCH Changeover Type from 250A to 2500A Table of Contents Preamble 1.1 Theoretical base 1.2 Selection the size of automatic transfer switch 1.3 Automatic transfer switch components

More information

Equipment: Power Supply, DAI, Variable resistance (8311), Variable inductance (8321)

Equipment: Power Supply, DAI, Variable resistance (8311), Variable inductance (8321) Lab 4: 3-phase circuits. Objective: to study voltage-current relationships in 3-phase circuits; to learn to make delta and Y connections; to calculate and measure real, apparent, and reactive powers. Equipment:

More information

Math for the General Class Ham Radio Operator. A prerequisite math refresher for the math phobic ham

Math for the General Class Ham Radio Operator. A prerequisite math refresher for the math phobic ham Math for the General Class Ham Radio Operator A prerequisite math refresher for the math phobic ham What We Will Cover Write these down! Ohm s Law Power Circle What We Will Cover Write these down! What

More information

User Manual V1.0 2014 SDM220MODBUS. Single-Phase Two Module DIN rail Meters

User Manual V1.0 2014 SDM220MODBUS. Single-Phase Two Module DIN rail Meters SDM220MODBUS Single-Phase Two Module DIN rail Meters Measures kwh, Kvarh, KW, Kvar, KVA, PF, Hz, dmd, V, A, etc. Di-directional measurement IMP & EXP Two pulse outputs RS485 Modbus Din rail mounting 36mm

More information

HARDWARE MANUAL. Ixx24-A 1/20. Val Controls A/S Limfjordsvej 3 DK-6715 Esbjerg N Tel. +45 7547 0600 vc@valcontrols.com www.valcontrols.

HARDWARE MANUAL. Ixx24-A 1/20. Val Controls A/S Limfjordsvej 3 DK-6715 Esbjerg N Tel. +45 7547 0600 vc@valcontrols.com www.valcontrols. HARDWARE MANUAL Ixx24-A 1/20 Table of contents 1 General... 3 1.1 Safety instructions... 3 1.2 Environment... 3 1.3 Mounting and dimension... 3 2 Communication... 4 2.1 Control loop AI0 and Transmitter

More information

[F/T] [5] [KHz] [AMP] [3] [V] 4 ) To set DC offset to -2.5V press the following keys [OFS] [+/-] [2] [.] [5] [V]

[F/T] [5] [KHz] [AMP] [3] [V] 4 ) To set DC offset to -2.5V press the following keys [OFS] [+/-] [2] [.] [5] [V] FG085 minidds Function Generator Manual of Operation Applicable Models: 08501, 08501K, 08502K, 08503, 08503K Applicable Firmware Version: 1 ) 113-08501-100 or later (for U5) 2 ) 113-08502-030 or later

More information

Single Output Switching Power Supply

Single Output Switching Power Supply .. RS- Code: CLP-A Single Output Switching Power Supply SPECIFICATION MODEL OUTPUT INPUT PROTECTION ENVIRONMENT SAFETY EMC (Note 6) OTHERS NOTE DC VOLTAGE RATED CURRENT CURRENT RANGE RATED POWER RIPPLE

More information

Multi-Function Ground

Multi-Function Ground Multi-Function Ground Resistance SOIL RESISTIVITY TEster Model 6470-B Now measure ground resistance, soil resistivity and bonding resistance with one instrument! 2- and 4-Wire Bond Resistance/Continuity

More information

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous Safety relay for monitoring E-STOP pushbuttons. Approvals Unit features Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous 1 auxiliary contact (N/C), instantaneous Safe separation of

More information

Model 8220. POWER QUALITY ANALYZERS, METERS & LOGGERS Power Quality Meter

Model 8220. POWER QUALITY ANALYZERS, METERS & LOGGERS Power Quality Meter Special product features '''' ENERGY METER ''' MEASURES RPM POWER QUALITY ANALYZERS, METERS & LOGGERS Power Quality Meter Model A measurement tool for electrical parameters and distribution network disturbances

More information

Inductive Sensors Single or Dual Loop Detectors Type LD with teach-in

Inductive Sensors Single or Dual Loop Detectors Type LD with teach-in Inductive Sensors Single or Dual Loop Detectors Type LD with teach-in Single or Dual loop detector Automatically adjustment of detection level Manual sensitivity for compensations of variations Easy installation

More information

1587/1577. Insulation Multimeters. Technical Data. Two powerful tools in one.

1587/1577. Insulation Multimeters. Technical Data. Two powerful tools in one. 1587/1577 Insulation Multimeters Technical Data Two powerful tools in one. The Fluke 1587 and 1577 Insulation Multimeters combine a digital insulation tester with a full-featured, true-rms digital multimeter

More information

User's Guide. True RMS Industrial Multimeter

User's Guide. True RMS Industrial Multimeter User's Guide 97650 True RMS Industrial Multimeter Ω C ã F ã 10A V µ 10A V ã ã ma A Introduction This meter measures AC/DC Voltage, AC/DC Current, Resistance, Capacitance, Frequency (electrical & electronic),

More information

TESLA Recorder Power Metering Setup Configuration for 3 and 2 Element Watt/VAR Metering

TESLA Recorder Power Metering Setup Configuration for 3 and 2 Element Watt/VAR Metering TESLA Recorder Power Metering Setup Configuration for 3 and 2 Element Watt/VAR Metering Introduction This application note will assist the user to set up 3-phase metering to monitor Watt, VAR and VA power

More information

Intelligent chart recorder for compressed air and gases. Measurement - control - indication - alarm - recording - evaluation

Intelligent chart recorder for compressed air and gases. Measurement - control - indication - alarm - recording - evaluation DS 500 Intelligent chart recorder for compressed air and gases Measurement - control - indication - alarm - recording - evaluation new Advantages at a glance: Clear layout: 7" colour screen with touch

More information

3½ DIGIT VOLTMETER MODULE LED- / LCD- SERIES

3½ DIGIT VOLTMETER MODULE LED- / LCD- SERIES 12.02 EA 4035-SERIES 3½ DIGIT VOLTMETER MODULE LED- / LCD- SERIES Splashproof 35,1x22,4 mm FEATURES * IP65 * 2 LED AND 2 LCD TYPES * EASY TO USE OR COMPATIBLE TO DATEL * ±200mV D.C. FULL SCALE READING

More information

DCS Input/Output Relay Card Series

DCS Input/Output Relay Card Series Input/Output Relay Card Series I/O RELAY CARD (with loopback test function) 8N The 8N series I/O Relay Cards easily and quickly standardize and facilitate installation of the relay board. Loopback test

More information

TQ SMD RELAYS TQ SMD LOW-PROFILE SURFACE-MOUNT RELAY FEATURES SPECIFICATIONS

TQ SMD RELAYS TQ SMD LOW-PROFILE SURFACE-MOUNT RELAY FEATURES SPECIFICATIONS LOW-PROFILE SURFACE-MOUNT RELAY RELAYS.55 5.6. FEATURES Low-profile: 6 mm.36 inch (Tape height: max. 6.5 mm.56 inch) Tape and reel package is available as standard packing style Surge withstand between

More information

650W Single Output Power Supply

650W Single Output Power Supply AK-650 series Features : Universal AC input with active PFC Programmable output Voltage ( 0% ~ 05% ) Programmable output Current ( % ~ 05% ) High efficiency up to 9% + / 0.5A auxiliary output Intelligent

More information

UMEC International Corporation

UMEC International Corporation UP1301A SERIES 130 Watt Open Frame Switchers Small Size 3*5*1.2(inches) Universal Input to 264 VAC Low Power Consumption Overvoltage Protection Continuous Short Circuit Protection Over Temperature Protection

More information

CATHODIC PROTECTION TRANSFORMER RECTIFIER (CPTR)

CATHODIC PROTECTION TRANSFORMER RECTIFIER (CPTR) CATHODIC PROTECTION TRANSFORMER RECTIFIER (CPTR) Fig1. CPTR SMART CONTROL PRECISION CUSTOMIZED MANUAL OR AUTO SCR OR DIODE DRY TYPE SWITCH MODE DRY TYPE SCR OR DIODE OIL TYPE 1 INDEX PAGE 1. Cover 2. Index

More information

Electronic Control Devices The European Product Catalogue 2007

Electronic Control Devices The European Product Catalogue 2007 FX14 Field Controller (1/4) FX14 Field Controller The FX14 is an equipment field controller in the Facility Explorer range of products. The controller is designed specifically for commercial Heating, Ventilating,

More information

MODEL 1211 CURRENT PREAMPLEFIER

MODEL 1211 CURRENT PREAMPLEFIER MODEL 1211 CURRENT PREAMPLEFIER Phone: (607)539-1108 Email: info@dlinstruments.com www.dlinstruments.com The Model 1211 Current Preamplifier was designed to provide all of the features required of a modern

More information

Agilent 4339B/4349B High Resistance Meters

Agilent 4339B/4349B High Resistance Meters Agilent 4339B/4349B High Resistance Meters Technical Overview Within Budget Without Compromise Introducing the Agilent Technologies 4339B and 4349B High Resistance Meters Used for Making Ultra- High Resistance

More information

Bulletin 150 SMC Flex Smart Motor Controller Specifications

Bulletin 150 SMC Flex Smart Motor Controller Specifications Specifications Specifications Standard Features Optional Features Installation Setup Communications Power Wiring Control Wiring Keypad Software Starting and Stopping Modes Protection and Diagnostics Metering

More information

HI/ICMI UVR-1 Universal Voltage Regulator Control

HI/ICMI UVR-1 Universal Voltage Regulator Control HI Document No. 2.4.32, Revision 1 ICMI Revision August 25, 2005 Specifications HI/ICMI UVR-1 Universal Voltage Regulator Control Howard Industries Utility Products Division Howard Industries, Inc. 3225

More information

U1602A Handheld Oscilloscopes, 20 MHz

U1602A Handheld Oscilloscopes, 20 MHz Products & Services Technical Support Buy Industries About Agilent United States Home >... > Oscilloscopes > U1600A Series handheld oscilloscopes (2 models) > U1602A Handheld Oscilloscopes, 20 MHz Product

More information

A reasonable, new furnace (mid efficiency) has the following electrical requirements:

A reasonable, new furnace (mid efficiency) has the following electrical requirements: June 2007 Power Backup Systems for Your Home. As promised from a previous safety meeting, a couple of options to protect you home in the event of a power failure. These options are for the most serious,

More information

Application Note TMA Series

Application Note TMA Series 1W, SIP, Single & Dual Output DC/DC Converters Features SIP Package with Industry Standard Pinout Package Dimension: 19.5 x 10.2 x 6.1 mm (0.77 x 0.4 x 0.24 ) 5V&12V Models 19.5 x 10.2 x 7.1 mm (0.77 x

More information

Outer Diameter 23 φ mm Face side Dimension 20.1 φ mm. Baffle Opening. Normal 0.5 Watts Maximum 1.0 Watts Sine Wave.

Outer Diameter 23 φ mm Face side Dimension 20.1 φ mm. Baffle Opening. Normal 0.5 Watts Maximum 1.0 Watts Sine Wave. 1. MODEL: 23CR08FH-50ND 2 Dimension & Weight Outer Diameter 23 φ mm Face side Dimension 20.1 φ mm Baffle Opening 20.1 φ mm Height Refer to drawing Weight 4.0Grams 3 Magnet Materials Rare Earth Size φ 9.5

More information

Isolated AC Sine Wave Input 3B42 / 3B43 / 3B44 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Isolated AC Sine Wave Input 3B42 / 3B43 / 3B44 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM Isolated AC Sine Wave Input 3B42 / 3B43 / 3B44 FEATURES AC averaging technique used to rectify, amplify, and filter 50 Hz to 400 Hz sine-wave signals. Accepts inputs of between 20 mv to 550 V rms to give

More information

SHARKY 775 COMPACT ENERGY METER ULTRASONIC

SHARKY 775 COMPACT ENERGY METER ULTRASONIC APPLICATION The ultrasonic compact energy meter can be used for measuring the energy consumption in heating / cooling application for billing purposes. FEATURES 4 Approval for ultrasonic meter with dynamic

More information

Uninterruptible Power Supply

Uninterruptible Power Supply 96-01101 / rev. 2e / 2-2-12 Uninterruptible Power Supply EXCEPTIONAL SUPPORT & PROTECTION Uninterruptible Power Supply with Energy Saver design that is optimized to address the needs of A/V systems Features

More information

Electronic Control Devices The European Product Catalogue 2007

Electronic Control Devices The European Product Catalogue 2007 FX07 Field Controller (1/4) FX07 Field Controller Display Model Dimensions in mm (inches) The FX07 is a terminal unit controller in the Facility Explorer range of products. The controller is designed specifically

More information

Transformer circuit calculations

Transformer circuit calculations Transformer circuit calculations This worksheet and all related files are licensed under the Creative Commons Attribution License, version 1.0. To view a copy of this license, visit http://creativecommons.org/licenses/by/1.0/,

More information

AC/DC Power Modules C B. TML Series, 20 & 40 Watt. Features. 20 Watt Models

AC/DC Power Modules C B. TML Series, 20 & 40 Watt. Features. 20 Watt Models TML Series, 0 & 0 Watt Features C B Scheme LVD UL 090- Encapsulated power supplies with increased power density Replaces TML and TML 0 series PCB mount or chassis mount with screw terminals Single, dual

More information

Physical Specifications (Custom design available.)

Physical Specifications (Custom design available.) Helmholtz Coils A useful laboratory technique for getting a fairly uniform magnetic field, is to use a pair of circular coils on a common axis with equal currents flowing in the same sense. For a given

More information